511/21337. CAK; Big Rapids Armory - Renovate Armory
Solicitation number
RFQ - 171 - 230000000114
Issued by
Mecosta County, Michigan

About this file

This document is a Project Manual for the "RENOVATE ARMORY - BIG RAPIDS" project, being conducted by the DEPARTMENT OF MILITARY AND VETERANS AFFAIRS for the State of Michigan and Mecosta County. The project involves the selective demolition and renovation of an armory building located at 15900 190th Avenue in Big Rapids, Michigan. The project manual provides detailed specifications across 33 divisions of work, including site work, concrete, masonry, metals, wood and plastics, thermal and moisture protection, openings, finishes, specialties, furnishings, plumbing, HVAC, electrical, and communications systems. Key dates include a 12/09/2022 publication date and no explicit bid or award dates are provided. The contract will be for the duration of the renovation project.

The document also includes available project information, such as a geotechnical report, topographic survey, and asbestos and lead-based paint reports. These reports provide details on existing site conditions that bidders should consider. No specific pricing terms, set asides, or funding sources are mentioned in the provided information. Bidders will need to submit their proposals through the State of Michigan's SIGMA VSS system, following the provided instructions for electronic submission.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tower Pinkster Titus Associates, Inc.

242 East Kalamazoo Avenue, Suite 100, Kalamazoo, MI 49007-5828

4 East Fulton Street, Suite 200, Grand Rapids, MI 49503

RENOVATE ARMORY - BIG RAPIDS

PROJECT MANUAL

12/09/2022

OWNER

DEPARTMENT OF MILITARY AND VETERANS AFFAIRS

15900 190TH AVENUE

BIG RAPIDS, MI 49307

PROJECT NUMBER

26A4622026

Architect’s Project No. 21-502.00 State File No. 511/21337.CAK

State Index No. 1290

VOLUME NUMBER 1

Divisions 00 Through 14

This page intentionally left blank.

PROJECT NO. 21-502.00 TABLE OF CONTENTS

RENOVATE ARMORY - BIG RAPIDS 1

DEPARTMENT OF MILITARY AND VETERANS AFFAIRS 12/09/2022

[Copyright] 2022 Tower Pinkster Titus Associates - All Rights Reserved

TABLE OF CONTENTS

DIVISION 00 — PROCUREMENT AND CONTRACTING REQUIREMENTS

00 3100 - AVAILABLE PROJECT INFORMATION

- GEOTECHNICAL REPORT

- ASBESTOS & LEAD BASE PAINT BUILDING SURVEY

- BULK SAMPLE ANALYTICAL REPORT

00 6323 - CADD FILE TRANSFER WAIVER

00 6324 - BIM TRANSFER WAIVER

00 7343 - WAGE RATE REQUIREMENTS

DIVISION 01 — GENERAL REQUIREMENTS

See MichSPEC

DIVISION 02 — EXISTING CONDITIONS

02 4119 - SELECTIVE DEMOLITION

DIVISION 03 — CONCRETE

03 3000 - CAST-IN-PLACE CONCRETE

03 6000 - POST INSTALLED ANCHORS

DIVISION 04 — MASONRY

04 0110 – MASONRY CLEANING

04 2000 - UNIT MASONRY

DIVISION 05 — METALS

05 1200 - STRUCTURAL STEEL FRAMING

05 2100 - STEEL JOIST FRAMING

05 3100 - STEEL DECKING

05 4000 - COLD-FORMED METAL FRAMING

05 5213 - PIPE AND TUBE RAILINGS

DIVISION 06 — WOOD, PLASTICS, AND COMPOSITES

06 1000 - ROUGH CARPENTRY

06 1600 - SHEATHING

06 4116 - PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS

06 6116 - SOLID SURFACING FABRICATIONS

RENOVATE ARMORY - BIG RAPIDS 2

DIVISION 07 — THERMAL AND MOISTURE PROTECTION

07 2100 - THERMAL INSULATION

07 2119 - FOAMED-IN-PLACE INSULATION

07 2413 - POLYMER-BASED EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)

07 5323 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

07 7100 - ROOF SPECIALTIES

07 8413 - PENETRATION FIRESTOPPING

07 8443 - JOINT FIRESTOPPING

07 9200 - JOINT SEALANTS

07 9219 - ACOUSTICAL JOINT SEALANTS

DIVISION 08 — OPENINGS

08 0671 - DOOR HARDWARE SCHEDULE

08 1113 - HOLLOW METAL DOORS AND FRAMES

08 3113 - ACCESS DOORS AND FRAMES

08 3613 - SECTIONAL DOORS

08 4113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

08 7100 - DOOR HARDWARE

08 8000 - GLAZING

08 8813 - FIRE-RATED GLAZING

DIVISION 09 — FINISHES

09 2400 - CEMENT PLASTERING

09 2900 - GYPSUM BOARD

09 3000 - TILING

09 5123 - ACOUSTICAL TILE CEILINGS

09 6513 - RESILIENT BASE AND ACCESSORIES

09 6566 - RESILIENT ATHLETIC FLOORING

09 6813 - TILE CARPETING

09 9114 - EXTERIOR PAINTING

09 9123 - INTERIOR PAINTING

DIVISION 10 — SPECIALTIES

10 1453 - TRAFFIC SIGNAGE

10 2113.19 - PLASTIC TOILET COMPARTMENTS

10 2213 - WIRE MESH PARTITIONS

10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES

10 4413 - FIRE PROTECTION CABINETS

10 4416 - FIRE EXTINGUISHERS

10 5113 - METAL LOCKERS

DIVISION 12 — FURNISHINGS

12 3661.16 - SOLID SURFACING COUNTERTOPS

RENOVATE ARMORY - BIG RAPIDS 3

VOLUME 2

DIVISION 22 — PLUMBING

22 0500 - COMMON WORK RESULTS FOR PLUMBING

22 0523 - GENERAL DUTY VALVES FOR PLUMBING PIPING (2 and smaller)

22 0529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

22 0553 - IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

22 0700 - PLUMBING INSULATION

22 1116 - DOMESTIC WATER PIPING

22 1119 - DOMESTIC WATER PIPING SPECIALTIES

22 1316 - SANITARY WASTE AND VENT PIPING

22 1319 - SANITARY WASTE PIPING SPECIALTIES

22 1413 - FACILITY STORM DRAINAGE PIPING

22 1423 - STORM DRAINAGE PIPING SPECIALTIES

22 4000 - PLUMBING FIXTURES

DIVISION 23 — HEATING VENTILATING AND AIR CONDITIONING

23 0500 - COMMON WORK RESULTS FOR HVAC

23 0513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

23 0519 - METERS AND GAGES FOR HVAC PIPING

23 0523 - GENERAL DUTY VALVES FOR HVAC PIPING

23 0529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

23 0553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

23 0593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 0700 - HVAC INSULATION

23 0900 - HVAC INSTRUMENTATION AND CONTROLS

23 2113 - HYDRONIC PIPING

23 3113 - METAL DUCTS

23 3300 - AIR DUCT ACCESSORIES

23 3713 - DIFFUSERS, REGISTERS, AND GRILLES

23 7200 - AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

23 7413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

23 8216 - AIR COILS

DIVISION 26 — ELECTRICAL

26 0500 - COMMON WORK RESULTS FOR ELECTRICAL

26 0519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

26 0533 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS

26 0536 - CABLE TRAYS FOR ELECTRICAL SYSTEMS

26 0543 - UNDERGROUND DUCTS AND RACEWAYS FOR ELECTRICAL SYSTEMS

26 0544 - SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING

26 0553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS

26 0923 - LIGHTING CONTROL DEVICES

RENOVATE ARMORY - BIG RAPIDS 4

26 2416 - PANELBOARDS

26 2726 - WIRING DEVICES

26 5100 - INTERIOR LIGHTING

26 5600 - EXTERIOR LIGHTING

DIVISION 27 — COMMUNICATIONS

27 0500 – DATA COMMUNICATION SYSTEM

DIVISION 28 — ELECTRONIC SAFETY AND SECURITY

28 3100 - FIRE DETECTION AND ALARM

DIVISION 31 — EARTHWORK

31 1000 - SITE CLEARING

31 2000 - EARTH MOVING

31 3116 - TERMITE CONTROL

DIVISION 32 — EXTERIOR IMPROVEMENTS

32 1216 - ASPHALT PAVING

32 1313 - CONCRETE PAVING

32 1373 - CONCRETE PAVING JOINT SEALANTS

32 3113 - CHAIN LINK FENCES AND GATES (sf2)

32 3223 - SEGMENTAL RETAINING WALLS

32 9200 - TURF AND GRASSES (sf0)

DIVISION 33 — UTILITIES

33 4100 - STORM UTILITY DRAINAGE PIPING

PROJECT NO. 21-502.00 AVAILABLE PROJECT INFORMATION

RENOVATE ARMORY - BIG RAPIDS 00 3100 - 1

SECTION 00 3100 - AVAILABLE PROJECT INFORMATION

1.1 EXISTING REPORTS AND SURVEYS

A. SUBSURFACE INVESTIGATION REPORT

B. A copy of a geotechnical report with respect to the building site is available for viewing:

1. Title: Boring Location plan

2. Date: 3/32/2022

3. Prepared by: MTC

4. Included in the Project Manual

C. This report identifies properties of below grade conditions and offers recommendations for the design of foundations, prepared primarily for the use of the Architect.

D. The recommendations described shall not be construed as a requirement of this Contract, unless specifically referenced in the Contract Documents.

E. This report, by its nature, cannot reveal all conditions that exist on the site. Should subsurface conditions be found to vary substantially from this report, changes in the design and construction of foundations will be made, with resulting credits or expenditures to the Contract Price accruing to the Owner.

F. The soil boring logs from this report are included with this document.

1.2 TOPOGRAPHIC SURVEY

A. A copy of a topographic survey with respect to the project site is available for viewing:

1. Title: Topographic Survey

2. Date: 3/8/2022

3. Prepared by: Prein & Newhof

4. View at the office of Towerpinkster and DMVA

B. This survey identifies grade elevations prepared primarily for the use of the Architect in establishing new grades and identifying natural water shed.

C. This survey identifies conditions of existing construction prepared primarily for the use of the Architect in establishing the extent of the new versus existing work.

D. This survey includes a photographic record of existing conditions visible.

1.3 ASBESTOS CONDITIONS SURVEY

A. A copy of asbestos and lead base paint report is available for viewing:

1. Title : Asbestos & Lead Base paint report

2. Date: 2/6/2008

3. Prepared by: Asbestos Abatement, Inc.

PROJECT NO. 21-502.00 AVAILABLE PROJECT INFORMATION

RENOVATE ARMORY - BIG RAPIDS 00 3100 - 2

4. Included in the Project Manual

B. A copy of bulk sample analytical report is available for viewing

1. Title : Bulk Sample Analytical report

2. Date: 1/15/2014

3. Prepared by: Fibertec industrial hygiene services, inc.

4. Included in the project Manual

END OF DOCUMENT 00 3100

ASBESTOS & LEAD BASED PAINT

BUILDING SURVEY

Of

The Big Rapids Armory

15900 190th Ave.

Big Rapids, Michigan

Completed For:

The Michigan Department of Military and Veterans Affairs

By

Asbestos Abatement, Inc.

2420 N. Grand River Lansing, MI 48906

February 6, 2008

Project No. 070180

Table of Contents

Introduction

Facility Information

Asbestos Background

Survey Procedures

Findings

Recommendations

Survey Data

Asbestos & Lead Based Paint Building Survey Big Rapids Armory

Introduction

The following Asbestos and Lead Based Paint Building Survey Report was completed for the Big Rapids Armory. Survey work includes the main building. This survey was conducted to satisfy the requirements of CFR 1926.1101(k)(2)(i) – Asbestos Standards for Construction, CFR

1926.62 – Lead in Construction, and the National Emissions Standard for Hazardous Air Pollutants (NESHAPS).

Asbestos Background

Asbestos is a naturally occurring mineral. It is distinguished from other minerals by the fact that its crystals form long, thin fibers. Deposits of asbestos are found throughout the world. The primary sites of commercial production are: Canada, China, Brazil, Zimbabwe, and South Africa asbestos is also mined commercially in limited quantities in the United States, in California and Vermont.

Asbestos minerals are divided into two groups—serpentines and amphiboles. The two groups are distinguished by their crystalline structure. Serpentine minerals have a sheet or layered structure, whereas amphiboles have a chain or spike-like shape. The table below describes six asbestos minerals that are members of these two groups.

Group Mineral Description and Properties Serpentine Chrysotile • Green, gray, amber, or white fibers with a silky luster

• very high in tensile strength.

• Good electrical insulator under dry conditions.

Note: Chrysotile accounts for 95 percent of asbestos in buildings and commercial products.

Amphibole Amosite • Gray, yellow, or dark brown fibers with a pearly luster course texture

• low tensile strength Note: amosite is the second most likely type of asbestos to be found in buildings..

Crocidolite • Blue fibers with a silky or dull luster

• Good acid resistance

• Excellent thermal insulator

Tremolite • Gray-white, green, yellow, or blue fibers with a silky luster

• Moderately high degree of hardness

• Excellent acid and chemical resistance

Actinolite • Hard, green fibers with a silky luster

• Harsh texture and poor flexibility

• Low tensile strength

Anthophyllite • Yellow brown, gray, or white fibers with a harsh texture

• Poor flexibility and low tensile strength

• Good heat and acid resistance, and a good electrical insulator under humid conditions

Asbestos has been used in literally thousands of products. Collectively, these are referred to as asbestos-containing material (ACM). Asbestos gained wide-spread use because it was plentiful, Project No. 070180 February 6, 2008 readily available, and low in cost. Because of its unique properties – fire resistance, high tensile strength, poor heat and electrical conductivity, and being generally impervious to chemicals attacks – asbestos proved well-suited for many uses in the construction trades.

Asbestos-related diseases are chronic diseases, and symptoms usually do not appear for 15 to 40 years after initial exposures to airborne asbestos fibers. In nearly all cases, many years of exposure to high levels of airborne ACM is necessary for personnel to contract asbestos-related diseases.

The primary exposure route is inhalation. Inhaled fibers may become embedded in the bronchial tubes or alveoli, or they may pass through to the pleura—the lining of the chest cavity. Asbestos-related diseases include asbestosis, lung cancer, mesothelioma, and gastrointestinal cancers.

Survey Procedures

Survey work was conducted by Mr. John Rehkopf of Northern Analytical Services, LLC. Mr.

Rehkopf is a properly trained and accredited State of Michigan Asbestos Building Inspector (accreditation A16809).

To complete this survey, the Mr. Rehkopf reviewed available drawings, previous building inspection reports, and interviewed site personnel to determine building perimeters and construction/renovation dates. Once this information was obtained, Mr. Rehkopf began a detailed survey of the areas indicated on the attached drawing for the presence of suspect asbestos containing materials (ACM). Individual homogeneous rooms were identified and assigned a unique room number.

At the time this Survey was conducted, the Inspector had to assume all suspect ACM contained asbestos; because of this, selective interior demolition was prohibited. The Inspector made every attempt to locate and investigate wall and ceiling cavities, however it is assumed that there are remaining unknown cavities within the building. Further investigation must be conducted by properly trained and accredited personnel prior to or during any demolition or renovation activities taking place to determine the presence of ACM.

Once identified, each suspect ACM was assigned a unique identifying number, called a Homogeneous Material Number, and provided a written description, called a Homogeneous Material Description. Each Homogeneous Material was then categorized as thermal, surfacing, or miscellaneous; then quantified and classified as either friable or not friable. Please keep in mind that materials classified as not friable at the time of the survey may become friable overtime or during renovation activities. A few of the suspect ACM found in this building include drywall, floor tile, fire doors, pipe insulation, and ceiling tiles.

Identified suspect ACM were then either sampled for the presence of asbestos or assumed to contain asbestos. The Inspector made every attempt to collect samples from each identified suspect ACM, however in some cases sample collection was not feasible. An example of this

Project No. 070180 February 6, 2008 would be fire doors, in order to sample a fire door a whole must be drilled into the core of the door thus permanently damaging the door and potentially causing a fiber release.

Samples from each remaining suspect materials were collected in random locations. A unique Sample No. was assigned to each sample collected to link it to the corresponding material.

Sample numbers begin with the materials Homogeneous Material No., and then two figures starting with 01 were added to the end. For example, sample number 101 was collected from material number 1. If additional samples were collected from the same material, sample numbers increased consecutively, therefore sample numbers 101, 102, 103 would all be from Material No. 1.

The number of samples collected from each material was determined by regulatory requirements and the Inspector’s findings. Regulatory requirements for each of the three material classifications are as follows:

• Friable Surfacing Materials require either 3, 5, or 7 samples depending on the amount of material present. (3 for <1,000 sq.ft., 5 for 1,000 to 5,000 sq.ft., and 7 for >5,000 sq.ft.)

• Thermal system insulation requires a minimum of 3 samples

• Miscellaneous and not friable materials require a minimum of 1 sample.

Once collected, samples were properly packaged and shipped via Federal Express to an independent, properly accredited laboratory for analysis. Analytical results have been included at the end of the Survey Data Section for each building.

Findings

Asbestos

During the survey process nine suspect asbestos containing materials were identified. One of these suspect materials were identified through laboratory analysis to contain asbestos and two were assumed to contain asbestos. The attached Homogenous Material Reports provides more detail on each of the nine suspect asbestos containing materials and their asbestos content. The attached section titled Survey Reports provides a room by room detail of the homogeneous materials identified as suspect ACM and their asbestos content.

Project No. 070180 February 6, 2008

Lead Based Paint

The current primary color used in the building is white, however during sample collection it was evident that previous colors were used. Three different paint samples were sampled with results as follows:

Sample No. Color Results 101 Brown <0.03% 201 Tan <0.01%

Recommendations

Based on the findings of the Inspector, the following recommendations have been made:

• Contract a licensed Asbestos Project Designer to review upcoming renovation plans along with the asbestos inspection to properly design any necessary abatement projects.

• Contract a licensed asbestos abatement contractor to properly remove ACM that will likely be disturbed during upcoming renovation activities.

• Provide at a minimum 2 hours of asbestos Awareness Training to all maintenance/custodial staff assigned to the main building. Training should be site specific.

• It is recommended that any asbestos abatement activities be monitored by a third party asbestos consultant.

• Periodically re-inspect and assess the condition of materials that are either known or assumed to contain asbestos. Should a material become damaged, have it properly repaired or removed by a licensed abatement contractor. Please keep in mind that materials that are classified as not friable at the time of the survey, may become friable overtime or during renovation activities.

• Should a material be discovered that does not clearly match the materials identified in this report, contact Asbestos Abatement, Inc. to have the material properly tested for asbestos.

• Treat all painted surfaces as lead containing. Demolition or renovation activities should be conducted by properly trained personnel only.

Homogeneous Material Report

M at er ia l N o.

H om og en eo us M at er ia l D es cr ip tio n C at ag or y

F ri ab lit y A sb es to s

D et ec te d Pe rc en t A sb es to s

A sb es to s Ty pe Q ua nt ity U ni ts

H om og en eo us

M at er ia l R ep or t

Pr oj ec t N o

B ig

R ap id s A rm or y fir e do or s an d fra m es m is ce lla ne ou s no t f ria bl e as su m ed ea ch do or fr am e ca ul k m is ce lla ne ou s no t f ria bl e no no ne d et ec te d ln .ft al dr ic h co

. b oi le r

Th er m al f ria bl e as su ea ch pl as te r c ei lin g su rfa ci ng no t f ria bl no ne d et ec te d sq .ft x ce ilin g til e w ith ra nd om g ou ge s an d pi ts m is ce lla ne ou s fri ab le no ne d et ec te d sq

.ft dr yw al l a nd m ud m is ce lla ne ou s fri ab no ne d et ec te d sq .ft x flo or ti le m as tic -ta n w ith b ro w n st re ak s m is ce lla ne ou s fri ab le til e-ye s m as tic

-y es

8% ch ry so til e ch ry so til e sq

.ft m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es Th er m al fri ab no ne d et ec te d ea ch gl ue p od s

- t an su rfa ci ng no t f ria bl no ne d et ec te d sq .ft

W ed ne sd ay , F eb ru ar y

, 2

Pa ge o f 1

Survey Report

R oo

N o.

H om og en eo us

M at er ia l D es cr ip tio n

As be st os

D et ec te d

A sb es to s Ty pe Q ua nt ity un its C om m en ts

M at er ia l N o.

Su rv ey R ep or t Pr oj ec t N o

B ig R ap id s A rm or y al dr ic h co . b oi le r as su ea ch fir e do or s an d fra m es as su ea ch do or fr am e ca ul k no ne de te ct ed ln

.ft fir e do or s an d fra m es as su ea ch do or fr am e ca ul k no ct ed ln

.ft pl as te r c ei lin g no ct ed sq

.ft m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es no ct ed ea ch x flo or ti le m as tic

-ta n w ith b ro w n st re ak s til e-ye s m as tic -y es ch ry so til e ch ry so til e sq

.ft no c ar pe t m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es no ct ed ea ch pl as te r c ei lin g no ct ed sq

.ft x ce ilin g til e w ith ra nd om g ou ge s an d pi ts no ct ed sq

.ft x flo or ti le m as tic

-ta n w ith b ro w n st re ak s til e-ye s m as tic -y es ch ry so til e ch ry so til e sq

.ft m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es no ct ed ea ch ab ov e ce ilin g til e

W ed ne sd ay , F eb ru ar y

, 2

Pa ge f 4

H om og en eo us

M at er ia l D es cr ip tio n

As be ec te d

A sb es to s Ty pe Q ua nt ity un its C om m en ts

M at er ia l N o.

Su rv ey R ep or t Pr oj ec t N o

B ig R ap id s A rm or y do or fr am e ca ul k no ct ed ln

.ft fir e do or s an d fra m es as su ea ch x flo or ti le m as tic

-ta n w ith b ro w n st re ak s til e-ye s m as tic -y es ch ry so til e ch ry so til e sq

.ft no c ar pe t x ce ilin g til e w ith ra nd om g ou ge s an d pi ts no ct ed sq

.ft m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es no ct ed ea ch ab ov e ce ilin g til e do or fr am e ca ul k no ct ed ln

.ft x ce ilin g til e w ith ra nd om g ou ge s an d pi ts no ct ed sq

.ft fir e do or s an d fra m es as su ea ch x flo or ti le m as tic

-ta n w ith b ro w n st re ak s til e-ye s m as tic -y es ch ry so til e ch ry so til e sq

.ft un de r c ar pe t m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es no ct ed ea ch ab ov e ce ilin g til e do or fr am e ca ul k no ct ed ln

.ft fir e do or s an d fra m es as su ea ch x ce ilin g til e w ith ra nd om g ou ge s an d pi ts no ct ed sq

.ft

W ed ne sd ay , F eb ru ar y

, 2

Pa ge

H om og en eo us

M at er ia l D es cr ip tio n

As be ec te d

A sb es to s Ty pe Q ua nt ity un its C om m en ts

M at er ia l N o.

Su rv ey R ep or t Pr oj ec t N o

B ig R ap id s A rm or y dr yw al l a nd m ud no ct ed sq .ft un de r c ar pe t fir e do or s an d fra m es as su ea ch al dr ic h co . b oi le r as su ea ch dr yw al l a nd m ud no ct ed sq .ft x ce ilin g til e w ith ra nd om g ou ge s an d pi ts no ct ed sq

.ft do or fr am e ca ul k no ct ed ln

.ft fir e do or s an d fra m es as su ea ch x ce ilin g til e w ith ra nd om g ou ge s an d pi ts no ct ed sq

.ft dr yw al l a nd m ud no ct ed sq .ft pl as te r c ei lin g no ct ed sq

.ft no a cc es s ab ov e do or fr am e ca ul k no ct ed ln

.ft pl as te r c ei lin g no ct ed sq

.ft no a cc es s ab ov e do or fr am e ca ul k no ct ed ln

.ft

W ed ne sd ay , F eb ru ar y

, 2

Pa ge

H om og en eo us

M at er ia l D es cr ip tio n

As be ec te d

A sb es to s Ty pe Q ua nt ity un its C om m en ts

M at er ia l N o.

Su rv ey R ep or t Pr oj ec t N o

B ig R ap id s A rm or y fir e do or s an d fra m es as su ea ch do or fr am e ca ul k no ct ed ln

.ft fir e do or s an d fra m es as su ea ch fir e do or s an d fra m es as su ea ch do or fr am e ca ul k no ct ed ln

.ft gl ue p od s

- t an no ct ed sq

.ft fir e do or s an d fra m es as su ea ch do or fr am e ca ul k no ct ed ln

.ft m ud c om po un d in su la tio n on fi tti ng s an d ha ng er s on fi be rg la ss in su la te d lin es no ct ed ea ch ne er c ei lin g

W ed ne sd ay , F eb ru ar y

, 2

Pa ge

Sample Location Report

Sa pl e

N um be r

M at er ia l N o.

H om og en ou s M at er ia l D es cr ip tio n

R

Sa m pl e

L oc at io n

Sa m pl e

Lo ca tio n

R ep or t

Pr oj ec t N o

B ig

R ap id s A rm or y do or fr am e ca ul k at d oo r pl as te r c ei lin g so ut h w es t c or ne r o f c ei lin g x ce ili ng ti le w ith ra nd om g ou ge s a nd p its ne xt to d oo r dr yw al l a nd m ud so ut h ea st c or ne r x flo or ti le m as tic -ta n w ith b ro w n st re ak s at d oo r t o ud c om po un d in su la tio n on fi tti ng s a nd h an ge rs o n fib er gl as s i ns ul at ed li n so ut h w es t c or ne r ud c om po un d in su la tio n on fi tti ng s a nd h an ge rs o n fib er gl as s i ns ul at ed li n on u ni t h ea te r ud c om po un d in su la tio n on fi tti ng s a nd h an ge rs o n fib er gl as s i ns ul at ed li n so ut h ea st c or ne r gl ue p od s -ta n w es t w al l n ex t t o do or to

W ed ne sd ay , F eb ru ar y

, 2

Pa ge f 1

Laboratory Analysis

Sample Location Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

160800216

Attn: John Rehkopf Northern Analytical Services 21391 13 Mile Rd Leroy, MI 49655

Customer PO:

Received: 01/08/08 9:00 AM

BIG RAPIDS ARMORY

Customer ID: NOAN22

Fax: (866) 214-4739 Phone: (231) 679-0005 Project:

EMSL Order:

EMSL Proj:

1/9/2008Analysis Date:

Report Date: 1/9/2008

EMSL Analytical 2001 East 52nd St., Indianapolis, IN 46205 Phone: (317) 803-2997 Fax: (317) 803-3047 Email: indianapolislab@emsl.com

160800216-0001

Gray None Detected

Non-Fibrous Homogeneous

Non-fibrous (other)100%

160800216-0002

White None Detected

Non-Fibrous Homogeneous

Non-fibrous (other)60% Quartz40%

160800216-0003

White/Tan None Detected

Fibrous Heterogeneous

Cellulose40% Min. Wool30%

Non-fibrous (other)5% Perlite25%

601/A Joint Compound 160800216-0004

White None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

601/B Drywall 160800216-0004A

White/Tan None Detected

Fibrous Heterogeneous

Cellulose40% Gypsum60%

701/A Floor Tile 160800216-0005

Beige Non-Fibrous Homogeneous

Chrysotile2%Non-fibrous (other)98%

701/B Mastic 160800216-0005A

Black Non-Fibrous Homogeneous

Chrysotile8%Non-fibrous (other)92%

160800216-0006

White/Gray None Detected

* Sample labeled by analyst

Fibrous Heterogeneous

Min. Wool40% Non-fibrous (other)60%

Richard Harding, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL Indianapolis (NVLAP Lab Code 200188-0)

Margaret Phillips (11) mailto:indianapolislab@emsl.com

Sample Location Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

160800216

Attn: John Rehkopf Northern Analytical Services 21391 13 Mile Rd Leroy, MI 49655

Customer PO:

Received: 01/08/08 9:00 AM

BIG RAPIDS ARMORY

Customer ID: NOAN22

Fax: (866) 214-4739 Phone: (231) 679-0005 Project:

EMSL Order:

EMSL Proj:

1/9/2008Analysis Date:

Report Date: 1/9/2008

EMSL Analytical 2001 East 52nd St., Indianapolis, IN 46205 Phone: (317) 803-2997 Fax: (317) 803-3047 Email: indianapolislab@emsl.com

160800216-0007

Gray None Detected

Fibrous Homogeneous

Min. Wool40% Non-fibrous (other)60%

160800216-0008

White/Tan None Detected

Fibrous Heterogeneous

Min. Wool50% Non-fibrous (other)50%

160800216-0009

Tan None Detected

Non-Fibrous Homogeneous

Non-fibrous (other)100%

Richard Harding, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL Indianapolis (NVLAP Lab Code 200188-0)

Margaret Phillips (11)

ConcentrationAnalyzed NotesRDLLab ID: Lead

160800187

Attn: John Rehkopf Northern Analytical Services 21391 13 Mile Rd Leroy, MI 49655

Customer PO:

Received: 01/08/08 9:00 AM

BIG RAPIDS ARMORY

Customer ID: NOAN22

Fax: (866) 214-4739 Phone: (231) 679-0005 Project:

EMSL Order:

EMSL Proj:

Report Date: 1/8/2008

Lead in Paint Chips by Flame AAS (SW 846 3050B and 7420*)

EMSL Analytical 2001 East 52nd St., Indianapolis, IN 46205 Phone: (317) 803-2997 Fax: (317) 803-3047 Email: indianapolislab@emsl.com

<0.03 % wt1/8/20080001 0.03

Client Sample Collected: 1/7/2008101

<0.01 % wt1/8/20080002 0.01

Client Sample Collected: 1/7/2008201

Page 1 of 1PB w/RDL

Date Printed: 1/8/2008 3:56:22 PM

Doug Wiegand, Laboratory Manager or other approved signatory

Reporting limit is 0.01 % wt. The QC data associated with these sample results included in this report meet the method quality control requirements, unless specifically indicated otherwise. Unless noted, results in this report are not blank corrected . This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities.

* slight modifications to methods applied Samples received in good condition unless otherwise noted. Quality Control Data associated with this sample set is within acceptable limits, unless otherwise noted ACCREDITATIONS: AIHA Environmental Lead Laboratory Approval Program #157245

Drawing

Client Name:

Project Name:

Summary:

BULK SAMPLE ANALYTICAL REPORT

Fibertec IHS Project #34549-1

NVLAP Accreditation #101510-0

Asbestos Abatement, Inc.

DMVA Big Rapids Armory

2 Submitted Bulk Samples, 4 Sample Layers Analyzed.

1914 Holloway Drive, Holt, Michigan 48842

Telephone: (517) 699-0345 Facsimile: (517) 699-0382

Summary:

Date Sampled: Client P.O. #:

Date Submitted: C.O.C. #:

Date Analyzed:

Fibertec Sample

N Client I.D.

N A l t

1/15/2014 N/A 1/16/2014 N/A 1/16/2014

2 Submitted Bulk Samples, 4 Sample Layers Analyzed.

Non-Asbestos Containing No. No. Analyst

CBD

CBD

Description / Location Asbestos Type Portion

1 1 Tan tabular material, 12" x 12" floor tile, Recruiting Office. Layer 1 of 2.

NAD Non-fibrous material 97%

Black rubbery material 12" x 12" NAD Non-fibrous material 97%

Cellulose fibers 3%

CBD

CBD

1 1 Black rubbery material, 12 x 12 floor tile mastic, Recruiting Office.

Layer 2 of 2.

NAD Non-fibrous material 97% Cellulose fibers 3%

2 2 Tan tabular material, 12" x 12" floor tile, Front Lobby. Layer 1 of 2.

NAD Non-fibrous material 97% Cellulose fibers 3%

CBD2 2 Black rubbery material, 12" x 12" floor tile mastic, Front Lobby.

Layer 2 of 2.

NAD Non-fibrous material 97% y y

Cellulose fibers 3%

1914 Holloway Drive, Holt, Michigan 48842

Telephone: (517) 699-0345 Facsimile: (517) 699-0382

Comments

1914 Holloway Drive, Holt, Michigan 48842

Telephone: (517) 699-0345 Facsimile: (517) 699-0382

Comments

Bulk samples are analyzed using the USEPA Test Method EPA/600/R-93/116. The constituent percent reported represents an estimate of the area percent of the component. The test report relates only to items tested. This report is not intended to be used as a product endorsement by NVLAP or any agency of the U.S. Government. Fine fibers like those in floor tile may not be discernible by this method. This report shall not be reproduced, except in full, without the written approval of the laboratory. Individual sample layers are homogeneous, unless otherwise noted. Test items were received in acceptable condition. Revision 4.0 dated 12/8/2010.

If no asbestos was/were detected in the sample/samples the acronym NAD (no asbestos detected) will appear in the Asbestos Type column of the report.

Approved Signatory:

Date: 1/16/2014

1914 Holloway Drive, Holt, Michigan 48842

Telephone: (517) 699-0345 Facsimile: (517) 699-0382

PROJECT NO. 21-502.00 CADD FILE TRANSFER WAIVER

RENOVATE ARMORY - BIG RAPIDS 00 6323 - 1

SECTION 00 6323 - CADD FILE TRANSFER WAIVER

A. At your request, TowerPinkster will provide CADD files to your organization for your convenience and use in the preparation of shop drawings related to the above project, subject to the following terms and conditions:

1. Our electronic files are compatible with AutoCAD 2016 and newer software. We make no representation as to the compatibility of these files with your hardware or your software beyond the specified release of the referenced specifications.

2. Data contained on these electronic files are part of our instruments of service and shall not be used by you or anyone else receiving this data through or from you for any purpose other than as a convenience in the preparation of shop drawings for the referenced project. Any other use or reuse by you or by others will be at your sole risk and without liability or legal exposure to TowerPinkster. You agree to make no claim and hereby waive, to the fullest extent permitted by law, any claim or cause of action of any nature against us, our officers, directors, employees, agents or subsonsultants that may arise out of or in connection with your use of the electronic files.

3. Furthermore, you shall, to the fullest extent permitted by law, indemnify and hold us harmless against all damages, liabilities or costs, including reasonable attorneys’ fees and defense costs, arising out of or resulting from your use of these electronic files.

4. These electronic files are not construction documents. Differences may exist between these electronic files and corresponding hard-copy construction documents. We make no representation regarding the accuracy or completeness of the electronic files you receive. In the event that a conflict arises between the hard-copy construction documents prepared by us and the electronic files, the hard-copy construction documents shall govern. You are responsible for determining if any conflict exists. By your use of these electronic files, you are not relieved of your duty to fully comply with the contract documents, including, and without limitation, the need to check, confirm and coordinate all dimensions and details, take field measurements, verify field conditions and coordinate your work with that of other contractors for the project.

5. Because information presented on the electronic files can be modified, unintentionally or otherwise, we reserve the right to remove all indicia of ownership and/or involvement from each electronic display.

B. We will furnish you with electronic files of the following drawing sheets:

C. ____________________________________________________________________________________

D. AutoCad Version requested:

E. Architect’s copyright protected CAD drawings are available strictly for the use of preparing shop drawings.

Architect will email files upon receipt this form, fully executed.

F. Under no circumstances shall delivery of the electronic files for use by you be deemed a sale by us, and we make no warranties, either express or implied, or merchantability and fitness for any particular purpose. In no event shall we be liable for any loss or profit or any consequential damages as a result of your use or reuse of these electronic files.

PROJECT NO. 21-502.00 CADD FILE TRANSFER WAIVER

RENOVATE ARMORY - BIG RAPIDS 00 6323 - 2

1.2 REQUESTER’S STATEMENT

A. I have reviewed the terms of this request and am in agreement with the conditions stated.

B. ________________________________________________________ C. Requester’s signature

END OF DOCUMENT 00 6325

PROJECT NO. 21-502.00 BIM TRANSFER WAIVER

RENOVATE ARMORY - BIG RAPIDS 00 6324 - 1

SECTION 00 6324 - BIM TRANSFER WAIVER

INTENT

A. This document amends and supplements the Digital Data Licensing Agreement AIA C106 - 2013 for requests for BIM Model from the Architect. All provisions which are not so amended or supplemented remain in full force and effect.

B. At the request of the Contractor, subcontractor, lower-tier subcontractor, or material supplier, and receipt of signed copy of Digital Data Licensing Agreement AIA C106, the Architect will transmit or send BIM model(s) requested.

C. MODIFICATIONS TO AIA C106

D. ARTICLE 3 – LICENSE CONDITIONS

E. Add the following clauses after the first sentence in Article 3:

1. We make no representation as to the compatibility of these files with your hardware or your software beyond the specified release of the referenced specifications.

2. Data contained on these electronic files are part of our instruments of service and shall not be used by you or anyone else receiving this data through or from you for any purpose other than as a convenience in the support of construction coordination for the referenced project. Any other use or reuse by you or by others will be at your sole risk and without liability or legal exposure to Tower Pinkster Titus Associates. You agree to make no claim and hereby waive, to the fullest extent permitted by law, any claim or cause of action of any nature against us, our officers, directors, employees, agents or subconsultants that may arise out of or in connection with your use of the electronic files.

3. Furthermore, you shall, to the fullest extent permitted by law, indemnify and hold us harmless against all damages, liabilities or costs, including reasonable attorneys’ fees and defense costs, arising out of or resulting from your use of these electronic files.

4. These electronic files are not construction documents. Differences may exist between these electronic files and corresponding hard-copy construction documents. We make no representation regarding the accuracy or completeness of the electronic files you receive. In the event that a conflict arises between the hard-copy construction documents prepared by us and the electronic files, the hard-copy construction documents shall govern. You are responsible for determining if any conflict exists. By your use of these electronic files, you are not relieved of your duty to fully comply with the contract documents, including, and without limitation, the need to check, confirm and coordinate all dimensions and details, take field measurements, verify field conditions and coordinate your work with that of other contractors for the project.

5. Because information presented on the electronic files can be modified, unintentionally or otherwise, we reserve the right to remove all indicia of ownership and/or involvement from each electronic display.

END OF DOCUMENT 00 6324

PROJECT NO. 21-502.00 WAGE RATE REQUIREMENTS

RENOVATE ARMORY - BIG RAPIDS 00 7343 - 1

SECTION 00 7343 - WAGE RATE REQUIREMENTS

1.1 PREVAILING WAGE REQUIREMENTS

A. Payment of a minimum of the Davis Bacon Act Wage and Classifications is a requirement of this project.

1. If applicable, the Contractor (and its Subcontractors) for prime construction contracts in excess of $2,000 must comply with the Davis-Bacon Act (40 USC 3141-3148) as supplemented by Department of Labor regulations (29 CFR Part 5, “Labor Standards Provisions Applicable to Contracts Covering Federally Financed and Assisted Construction”).

2. The Contractor (and its Subcontractors) shall pay all mechanics and laborers employed directly on the site of the work, unconditionally and at least once a week, and without subsequent deduction or rebate on any account, the full amounts accrued at time of payment, computed at wage rates not less than those stated in the advertised specifications, regardless of any contractual relationship which may be alleged to exist between the Contractor or subcontractor and the laborers and mechanics.

3. The Contractor will post the scale of wages to be paid in a prominent and easily accessible place at the site of the work.

4. There may be withheld from the Contractor so much of accrued payments as the contracting officer considers necessary to pay to laborers and mechanics employed by the Contractor or any Subcontractor on the work the difference between the rates of wages required by the Contract to be paid laborers and mechanics on the work and the rates of wages received by the laborers and mechanics and not refunded to the Contractor or Subcontractors or their agents.

5. The Contractor shall maintain payrolls and basic records relating thereto for a period of three (3) years after the project; contractor shall submit Certified Payroll Reports using US Department of Labor Wage and Hour Division Form WH-347 for each weekly payroll to support and document compliance with the Davis Bacon Wage rates.

6. Davis Bacon wage and classification schedules applicable for this project/location are included.

B. Payment of a minimum of the prevailing wage rate is a requirement of this project. The current wage rate schedule for the project site is included.

C. Refer to this document for pertinent information. Failure to consult this document shall not relieve the contractor of his obligations therein.

END OF DOCUMENT 00 7343

https://www.law.cornell.edu/uscode/text/40/subtitle-II/part-A/chapter-31/subchapter-IV https://www.law.cornell.edu/cfr/text/29/part-5

00 0101 TP Cover Page V1
00 0110 - TP Table of Contents - Volume 1
00 3100 - AVAILABLE PROJECT INFORMATION
Big Rapids Survey report
Tile and Mastic Recruiting Office and Front Lobby
MTC REPORT
00 6323 - CADD FILE TRANSFER WAIVER
00 6324 - BIM TRANSFER WAIVER
00 7343 - WAGE RATE REQUIREMENTS