5-Euclid Roof Peplacement DSA Submittal Progress Set 261110.pdf
PDF 8 MB Posted
- Attached to
- Euclid & Monte Vista LLB
- Solicitation number
- C-267-523
- Issued by
- San Bernardino County, California
About this file
This is a Scope of Work drawing set for a roof tile replacement project at Euclid Elementary School, located at 1120 S. Euclid Avenue in Ontario, California, under the Ontario-Montclair Unified School District. The project involves the complete replacement of ceramic roof tiles on Building A, including the removal and disposal of existing roofing materials, installation of new roof tiles in accordance with manufacturer specifications, replacement of all roof gutters and downspouts, installation of new fascia wood blocking, and repair of eleven cracked wooden beams identified during site inspection. The scope also includes installation of new roof underlayment, flashing, and edge treatments, with work to comply with the 2025 California Building Code and applicable standards. The project requires continuous inspection by a DSA (Division of the State Architect) certified Class 3 Project Inspector employed by the district, and all work must adhere to Title 24 California Code of Regulations. The drawing set comprises seven sheets including site plans, framing plans, structural reinforcement details, sections, and wall details with enlarged elevations.
The project documentation specifies that all materials must be new and first quality, with structural and architectural materials meeting CBC standards and manufacturer recommendations. All substitutions affecting DSA-regulated items require approval through Construction Change Documents or Addenda before fabrication and installation. The contractor is responsible for coordinating work among all trades, maintaining site safety in accordance with Cal-OSHA regulations, and protecting existing equipment and roofing surfaces not included in the replacement scope. A DSA-accepted testing laboratory directly employed by the district must conduct all required special tests and inspections. The design professional statement certifies that the Path of Travel meets current CBC accessibility provisions, with identified non-compliant elements included in the project scope or documented as unreasonable hardship cases.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCOPE OF WORK
DRAWING INDEX
VICINITY MAP
T-1
T
IT
LE
S
H E
E T
GENERAL:
T-1 TITLE SHEET
ARCHITECTURAL:
A-1.0 OVERALL SITE PLAN AND ACCESS PATH OF TRAVEL
A-5.0 BUILDING 'A' - DEMO & NEW ROOF PLANS
A-5.1 BUILDING 'A' - FRAMING PLAN AND REINFORCEMENT DETAILS
A-6.0 BUILDING 'A' - SECTIONS
A-6.1 ENLARGED ELEVATIONS AND DETAILS
A-9.0 WALL SECTIONS AND DETAILS
TOTAL SHEETS = 7
1120 S. EUCLID AVE.
ONTARIO, CA 91762
EUCLID ELEMENTARY SCHOOL
ONTARIO-MONTCLAIR UNIFIED SCHOOL DISTRICT
GENERAL NOTES
CODES AND STANDARDS
DRAWING SYMBOLS
N
ABBREVIATIONS
APPLICABLE CODES
• 2025 CALIFORNIA ADMINISTRATIVE CODE (CAC), PART 1, TITLE 24 C.C.R.
• 2025 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.
• 2025 CALIFORNIA ELECTRICAL CODE (CEC) , PART 3, TITLE 24 C.C.R.
• 2025 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.
• 2025 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.
• 2025 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R.
• 2025 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R.
• 2025 CALIFORNIA EXISTING BUILDING CODE (CEBC), PART 10, TITLE 24 C.C.R
• 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE, PART 11, TITLE 24 C.C.R.
• 2025 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R.
• TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS
APPLICABLE STANDARDS
FOR A LIST OF APPLICABLE STANDARDS, INCLUDING CALIFORNIA AMENDMENTS TO THE NFPA STANDARDS, REFER TO CBC CHAPTER 35 AND CFC CHAPTER 80.
1. ALL WORK SHALL CONFORM TO 2025 EDITION TITLE 24, CALIFORNIA CODE OF REGULATIONS. (CCR).
2. CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY AN ADDENDA OR
CCD APPROVED BY THE DIVISION OF THE STATE OF ARCHITECT, AS REQUIRED BY SECTION 4-338, PART 1, TITLE 24, CCR.
3. A 'DSA CERTIFIED' PROJECT INSPECTOR EMPLOYED BY THE DISTRICT (OWNER) AND APPROVED BY
THE DIVISION OF THE STATE ARCHITECT SHALL PROVIDE CONTINUOUS INSPECTION OF THE WORK THE
DUTIES OF THE INSPECTOR ARE DEFINED IN SECTION 4-342, CALIFORNIA BUILDING STANDARDS
ADMINISTRATION CODE (PART 1,TITLE 24 (CCR.)
4. A DSA INSPECTOR WITH CLASS 3 CERTIFICATION IS REQUIRED FOR THIS PROJECT.
5. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS THAT THE WORK OF THE ALTERATION, REHABILITATION OR RECONSTRUCTION IS TO BE IN ACCORDANCE WITH TITLE 24, CALIFORNIA CODE
OF REGULATIONS. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NON-COMPLYING
CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN
THE FINISHED WORK WILL NOT COMPLY WITH TITLE 24, CALIFORNIA CODE OF REGULATIONS, A
CHANGE ORDER, OR A SEPARATE SET OF PLANS AND SPECIFICATIONS, DETAILING AND SPECIFYING
THE REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY THE DIVISION OF THE STATE
ARCHITECT BEFORE PROCEEDING WITH THE WORK.
6. THE DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE SHALL VERIFY BY APPROPRIATE
MEANS, SUBJECT TO DSA APPROVAL, AND SUBMIT A LETTER CERTIFYING THAT THE BUILDING
CONFORMS TO THE ORIGINAL DSA-APPROVED PLANS AND SPECIFICATIONS AND HAS NOT SUFFERED
STRUCTURAL DETERIORATION OR BEEN STRUCTURALLY ALTERED.
7. DETERIORATION OR EXISTING NON-COMPLIANT CONSTRUCTION: IF ANY CONDITION IS DISCOVERED
WHICH, IF LEFT UNCORRECTED, WOULD MAKE THE BUILDING NON-COMPLIANT WITH THE
REQUIREMENTS OF THE EDITION OF CBC IN FORCE AT THE TIME OF ORIGINAL CONSTRUCTION, THE
CONDITION MUST BE CORRECTED IN ACCORDANCE WITH CURRENT CODE REQUIREMENTS. A
CONSTRUCTION CHANGE DOCUMENT (CCD-TYPE A), OR A SEPARATE SET OF PLANS AND
SPECIFICATIONS DETAILING AND SPECIFYING THE REQUIRED REPAIR WORK SHALL BE SUBMITTED TO
AN APPROVED BY DSA BEFORE PROCEEDING WITH THE REPAIR WORK.
8. ALL CONSTRUCTION AND DEMOLITION SHALL BE IN ACCORDANCE WITH CFC CHAPTER 33, CEBC
CHAPTER 15, AND THE WRITTEN SITE SAFETY PLAN (SSP) PURSUANT TO DSA BULLETIN (BU) 24-05: FIRE
SAFETY DURING CONSTRUCTION AND DEMOLITION.
9. A DSA ACCEPTED TESTING LABORATORY DIRECTLY EMPLOYED BY THE DISTRICT SHALL CONDUCTALL
THE REQUIRED SPECIAL TESTS AND INSPECTIONS FOR THIS PROJECTS.
10. WHENEVER DSA FINDS ANY CONSTRUCTION WORK IS BEING PERFORMED IN A MANNER CONTRARY TO
THE PROVISIONS OF CALIFORNIA BUILDING CODE AND THAT WOULD COMPROMISE THE STRUCTURAL
INTEGRITY OF THE BUILDING, THE DEPARTMENT OF GENERAL SERVICES, STATE OF CALIFORNIA, IS
AUTHORIZED TO ISSUE A STOP WORK ORDER PER SECTION 4-334.1 CALIFORNIA ADMINISTRATIVE
CODE (PART 1, TITLE 24, CCR)
11. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND
ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES.
12. TITLE 24, PART 1-5 AND 9 MUST BE KEPT ON SITE DURING CONSTRUCTION.
13. ALL STRUCTURAL, ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING MATERIALS
INSTALLATION TO COMPLY WITH APPLICABLE CODES, STANDARDS AND MANUFACTURER'S
RECOMMENDATIONS.
14. SITE PROJECT INSPECTOR TO VERIFY COMPLETED IN-PLANT INSPECTOR INSPECTION CARD / VERIFIED
REPORT (DSA 152-IPI) FOR EACH RELOCATABLE BUILDING BEFORE INSTALLATION ON SITE.
15. THE PROJECT INSPECTOR ( PI ) SHALL WITNESS AND VERIFY GROUNDING.
16. CONTRACTOR & SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH & ENSURING
THAT ALL WORKMANSHIP AND/OR MATERIALS MEET C.B.C STANDARDS OF THE 2025 EDITION &
STANDARDS OF THE DIVISION OF THE STATE ARCHITECT & OTHER GOVERNING AGENCIES.
17. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON THE JOB SITE AND/OR SUPPLIER IN WHICH AFFECTS
THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR & COMPLYING WITH CORRECT
INSTALLATION & USE OF ALL MATERIALS. ALL MATERIALS SHALL BE NEW & FIRST QUALITY.
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK FOR ALL TRADES.
19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING
CONSTRUCTION & SHALL PROVIDE ADEQUATE SHORING & BRACING. SAFETY REQUIREMENTS SHALL
BE IN ACCORDANCE WITH ALL NATIONAL, STATE (CAL-OSHA) & LOCAL ORDNANCES.
20. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS ARE GIVEN AS THE
BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTIVE CONDITIONS
CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE ARCHITECT.
21. THESE PLANS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT. ANY REPRODUCTION OR USE
WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED. THE ARCHITECT ASSUMES NO
LIABILITY FOR THE UNAUTHORIZED USE OF THESE PLANS.
22. CONTRACTOR OPERATIONS SHALL NOT BLOCK, HINDER, IMPEDE OR OTHERWISE INHIBIT THE USE OR
REQUIRED EXITS AT ANY TIME. CONTRACTOR SHALL MAINTAIN UNOBSTRUCTED ACCESS TO FIRE
EXTINGUISHERS, FIRE HYDRANTS, TEMPORARY FIRE PROTECTION FACILITIES, STAIRWAYS & OTHER
ACCESS ROUTES FOR FIRE FIGHTING EQUIPMENT & OR PERSONNEL.
23. ALL SUBSTITUTIONS AFFECTING DSA REGULATED ITEMS SHALL BE CONSIDERED AS A CONSTRUCTION
CHANGE DOCUMENT (CCD) OR ADDENDA, AND SHALL BE APPROVED BY DSA PRIOR TO FABRICATION
AND INSTALLATION. (IR-A-6), (SECTION 4-338c), SUBSTITUTIONS SHALL BE FOR ANY MATERIAL, SYSTEM
OR PRODUCT THAT WOULD OTHERWISE BE REGULATED BY DSA.
24. A COPY OF THE APPROVED DRAWINGS, SPECIFICATIONS, ADDENDUMS AND CONSTRUCTION CHANGE
DOCUMENTS SHALL BE KEPT ON SITE DURING CONSTRUCTION.
25. CONSTRUCTION CHANGE DOCUMENTS (SECTION 4-338(c)) MUST BE SIGNED BY ALL OF THE
FOLLOWING: A/E OF RECORD, STRUCTURAL ENGINEER (WHERE APPLICABLE), DELEGATED
PROFESSIONAL ENGINEER (WHEN APPLICABLE), DSA.
26. PROJECT INSPECTOR AND TESTING LAB MUST BE EMPLOYED BY THE OWNER AND APPROVED BY ALL
THE FOLLOWING: A/E OF RECORD, STRUCTURAL ENGINEER (WHERE APPLICABLE), DSA.
-9
-0
P R
O
JE
C T
N U
M B
E R
D A
T E
R
E V
IS
IO
N
R O
O F
T
IL
E R
E P
LA
C
E M
E N
T
S . E
U C
LI
D
A V
E , O
N T
A R
IO
, C
A
E U
C
LI
D E
LE
M
E N
T A
R Y
S C
H O
O L
O N
T A
R
IO
-M O
N T
C
LA
IR
U
N
IF
IE
D
S C
H O
O L
D
IS
T R
IC
T
P R
O
JE
C T
S T
A T
U S
D E
S C
R
IP
T
IO
N
P R
O
JE
C T
S T
A T
U S
P R
O
JE
C T
D A
T E
P R
O
JE
C T
IS
S
U E
D
S G
H A
R C
H
IT
E C
T S
IN
C
A
LL
R
IG
H
T S
R E
S E
R V
E D
S E
A
LS
C
O N
S U
LT
A
N T
1. REPLACE ALL ROOF GUTTERS INSTEAD OF REPAIRING ONLY THE DAMAGED AND AFFECTED
PORTIONS.
2. REPLACE DOWNSPOUT LEADERS AS WHERE NEEDED, INSTEAD OF RE-USING EXISTING.
3. PROVIDE PAINT FINISH TO ALL EXISTING EXPOSED SURFACES OF THE ROOF CANOPY SCOPE
(EXCEPT PREFINISHED MATERIALS) INSTEAD OF PROVIDING PAINT FINISH ONLY TO NEW WORK.
4. INDICATE ALLOWANCE OF 8% MAX. OF TOTAL AREA OF EXISTING CANOPY SHEATHING TO BE
REPLACED (ONLY IF NEEDED).
5. REMOVE/DEMO EXISTING CANOPY EXTENSION THAT DO NOT HAVE ROOF TILE FINISH.
CLIENT / OWNER:
Ontario-Montclair Unified
School District
950 W. D. St, Ontario, CA 91762
(909) 459-2500 Brooke Murray
Brooke.Murray@omsd.net
ARCHITECT:
SGH Architects 707 Brookside Ave.
Redlands, CA 92373
(909) 375-3030
Michael Stephens mstephens@sgharch.com
STRUCTURAL ENGINEER:
RTM Engineering Consultants
1 Ada, Suite 100
Irvine, CA 92618
(909) 462-3200 Kevin Westervelt
Kevin.Westervelt@rtmec.com
N.I.C. NOT IN CONTRACT
EXISTING
CERAMIC TILE
EACH
LAV.
MFR.
MTL.
LAVATORY
METAL
MANUFACTURER
(N) NEW
FINISH
FLOW LINE
FLOOR
FIN.
F.L.
FLR.
CERAMIC TILE
CARPET
DETAIL
DOOR
DIAMETER
D.S. DOWNSPOUT
DET.
DIA.
CPT.
DWG. DRAWING
ARCH.
ANOD.
BOARD
CABINET
B.M.
CAB.
BD./BRD.
CLG. CEILING
ARCHITECT
ANODIZED
BENCH MARK
PLYWOOD
ON CENTER
H.C. HOLLOW CORE
EQUAL
ELEC. ELECTRICAL
INSUL. INSULATION
FINISH FLOOR
FINISH GRADE
F.F.
F.G.
F.D. FLOOR DRAIN
H.M. HOLLOW METAL
COLUMN
CENTER LINE
C.O. CLEAN OUT
COL.
ACT.
ASPHALTIC CONCRETE
ACOUSTIC TILE
AT THE RATE OF
CONTRACTOR
CONC. CONCRETE
CONT'R.
ALUM.
ADJ. ADJUSTABLE
ALUMINUM
A.D.
CONT. CONTINUOUS
AREA DRAIN
PLWD/PLYWD.
O.C.
C.F.C.I. CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
O.F.C.I.
A.F.F. ABOVE FINISHED FLOOR
O.H. OPPOSITE HAND
CLR. CLEAR
W.P. WATERPROOF
T.O.C. TOP OF CURB
W.R. WATER RESISTANT
U.N.O. UNLESS NOTED OTHERWISE
VCT
WOOD
WIDE
WC
WD.
VINYL COMPOSITE TILE
W.H. WATER HEATER
WDW. WINDOW
SHEET VINYL
WATER CLOSET
S.V.
T.O.S.
T.O.R.
TOP OF SHEATHING
TOP OF RIDGE
U.B.C. UNIFORM BUILDING CODE
TYP. TYPICAL
C.J. CONTROL JOINT
EXPANSION JOINT
N/A NOT APPLICABLE
P.H. PANIC HARDWARE
ABS.
A.B. ANCHOR BOLT
ABSOLUTE
AGGR. AGGREGATE
ALT. ALTERNATE
B.O. BOTTOM OF
B.U.R. BUILT-UP ROOF
C.M.U. CONCRETE MASONRY UNIT
CONN. CONNECTION
CONST. CONSTRUCTION
DBL. DOUBLE
DEMO. DEMOLISH
D.F. DRINKING FOUNTAIN
DIM. DIMENSION
D.W. DISHWASHER
ELEV. ELEVATOR
ELEVATION
E.P. ELECTRICAL PANEL
EQUIP. EQUIPTMENT
EXP. EXPANSION
EXT. EXTERIOR
HDR. HEADER
HDWR. HARDWARE
HORIZ. HORIZONTAL
HT. HEIGHT
HVAC HEATING, VENTILATING &
AIR CONDITIONING
IN. INCH
INT. INTERIOR
JAN. JANITOR
JT. JOINT
LAM. LAMINATE
L.F. LINEAL FOOT
MACH. MACHINE
MAX. MAXIMUM
MECH. MECHANICAL
MFR'G MANUFACTURING
MIN. MINIMUM
M.B. MARKER BOARD
MISC. MISCELLANEOUS
MTG. MOUNTING
NO. NUMBER
NTS NOT TO SCALE
OWNER FURNISHED,
CONTRACTOR INSTALLED
O.F.O.I. OWNER FURNISHED,
OWNER INSTALLED
O.D. OVERFLOW DRAIN
OPT. OPTIONAL
P.I.V. POST INDICATOR VALVE
PLAS. PLASTER
PROP. PROPERTY (LINE)
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
ST. STREET
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURAL
SUSP. SUSPENDED
SYM. SYMMETRICAL
T.O.W. TOP OF WALL
T.O.P. TOP OF PAVING
THK. THICK
TEMP. TEMPORARY
TB TACKBOARD
T&G TONGUE & GROOVE
VERT. VERTICAL
VEST. VESTIBULE
VTR VENT THROUGH ROOF
W
W/ WITH
WSCT WAINSCOT
WT. WEIGHT
YD YARD DRAIN
V.I.F. VERIFY IN FIELD
H. HIGH
ADA AMERICAN DISABILITY ACT
OMF ORNAMENTAL METAL FENCE
CLG. CEILING
M.I. MIRROR IMAGE
CENTER LINE
MTD. MOUNTED
PLMG. PLUMBING
GA. GAUGE
GL.
GYP BD/GB
GLASS
GYPSUM BOARD
GALV. GALVANIZED
F.O.C. FACE OF CONCRETE
F.V. FIELD VERIFY
F.O.S. FACE OF STUD
F.O.F. FACE OF FINISH
FT. FEET OR FOOT
FTG. FOOTING
FURN. FURNITURE
GLB. GLUE-LAM BEAM
R-VALUE THERMAL VALUE
RUBBER BASE
R.D. ROOF DRAIN
R.B.
PAINTED
P.STL. PRESSED STEEL
PTD.
SOLID CORE
STORM DRAIN
S.A.T.
S.C.
S.D.
SUSPENDED ACOUSTICAL TILE
P.T. PETROLEUM TREATED
PVC. POLYVINYLCHLORIDE
R.A. RETURN AIR
RAD. RADIUS
REFL. REFLECTED (CEILING PLAN)
REF. REFERENCE
REINF. REINFORCED
REQ'D REQUIRED
RM. ROOM
R.O. ROUGH OPENING
SEC. SECTION
SHTG. SHEATHING
SIM. SIMILAR
RCB RELOCATABLE
CLASSR0OM BUILDING
SHT. SHEET
W001A
ROOM
B101
A
B
C
D
A0.00
DOOR NUMBER
WINDOW NUMBER
WALL SIGNAGE NUMBER
DEMOLITION KEYNOTE
KEYNOTE NUMBER
REVISION NUMBER
ROOM NAME & NUMBER
A0.00
1 INTERIOR ELEVATION
NUMBER & SHEET NUMBER
A-9.1
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
EXTERIOR ELEVATION NUMBER
A-6.1 1
SECTION NUMBER
SHEET NUMBER
PROJECT
LOCATION
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E ) P
O R
TA
BL
E A#
-6
N .I.
S.
(E ) P
O R
TA
BL
E A#
-5
N .I.
S.
(E ) P
O R
TA
BL
E A#
-6
N .I.
S.
(E ) P
O R
TA
BL
E A#
-6
N .I.
S.
(E ) P
O R
TA
BL
E A#
-6
N .I.
S.
(E ) P
O R
TA
BL
E A#
-6
N .I.
S.
(E ) P
O R
TA
BL
E A#
-6
N .I.
S.
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E ) P
O R
TA
BL
E A#
-1
N
.I.
S.
(E) MULTI-PURPOSE
ROOM
A#04-106275 N.I.S.
(E) BLDG A
A#04-101953
(E) P2 PORTABLE
A#04-103526
N.I.S.
(E) P3 PORTABLE
A#04-103526
N.I.S.
N O
P A
R K
IN
G
VA
N
(E) PLAYGROUND
N.I.S.
W BELMONT ST.
S P
AL
M
A
VE
W RALSTON ST.
EU
C
LI
D
A
VE
AREA OF PROJECT SCOPE
(E) DISPERSAL AREA
(E) STAFF RESTROOM PER A#04-116732
(E) STUDENT RESTROOM PER A#04-116732
(E) PATH OF TRAVEL PER A#04-122968
PROPERTY LINE
NOT IN SCOPE OF WORK
LEGEND
PARKING TABULATION
STANDARD STALLS 45
STANDARD ACCESSIBLE 1
VAN ACCESSIBLE 1
TOTAL STALLS 47
EXISTING KEYNOTES
WHILE UNDERSTANDING THE AMERICANS WITH DISABILITIES ACT (ADA) AND TITLE 24 ARE SUBJECT TO VARYING INTERPRETATIONS AND NUANCES, TO THE BEST OF MY KNOWLEDGE, AS THE DESIGN
PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE, THE FOLLOWING STATEMENT (REQUIRED BY
THE DIVISION OF STATE ARCHITECT) IS TRUE AND CORRECT:
"DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE STATEMENT: THE POT IDENTIFIED IN
THESE CONSTRUCTION DOCUMENTS MEETS THE REQUIREMENTS OF THE CURRENT APPLICABLE
CALIFORNIA BUILDING CODE (CBC) ACCESSIBILITY PROVISIONS FOR PATH OF TRAVEL
REQUIREMENTS FOR ALTERATIONS, ADDITIONS AND STRUCTURAL REPAIRS. AS PART OF THE
DESIGN OF THIS PROJECT, THE POT WAS EXAMINED AND ANY ELEMENTS, COMPONENTS OR
PORTIONS OF THE POT THAT WERE DETERMINED TO BE NON-COMPLIANT WITH THE CBC HAVE BEEN IDENTIFIED AND THE CORRECTIVE WORK NECESSARY TO BRING THEM INTO COMPLIANCE HAS BEEN
INCLUDED WITHIN THE SCOPE OF THIS PROJECT’S WORK THROUGH DETAILS, DRAWINGS AND
SPECIFICATIONS INCORPORATED INTO THESE CONSTRUCTION DOCUMENTS. ANY NONCOMPLIANT
ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WILL NOT BE CORRECTED BY THIS
PROJECT BASED ON VALUATION THRESHOLD LIMITATIONS OR A FINDING OF UNREASONABLE
HARDSHIP ARE INDICATED IN THESE CONSTRUCTION DOCUMENTS.
DURING CONSTRUCTION, IF POT ITEMS WITHIN THE SCOPE OF THE PROJECT REPRESENTED AS CBC
COMPLIANT ARE FOUND TO BE NONCONFORMING BEYOND REASONABLE CONSTRUCTION
TOLERANCES, THE ITEMS SHALL BE BROUGHT INTO COMPLIANCE WITH THE CBC AS A PART OF THIS
PROJECT BY MEANS OF A CONSTRUCTION CHANGE DOCUMENT."
1 NOT USED
2 (E) 7'-0" HIGH STEEL FENCE PER A#04-122968.
3 (E) 7'-0" ACCESSIBLE GATE PER A#04-122968.
4 (E) DOOR 5lbs. MAX CLOSING FORCE
5 (E) PERIMETER 8'-0" HIGH CHAIN LINK FENCE A#04-122968.
6 (E) TRUNCATED DOMES PER A#04-122968.
7 (E) UNAUTHORIZED PARKING SIGN PER A#04-122968.
11 (E) A.C. PAVING
12 (E) GRASS / TURF
13 (E) ACCESSIBLE DRINKING FOUNTAIN PER A#04-122968.
TYP.
TYP.
TYP.
TYP.
TYP.
13 2
(E) SAFE DISPERSAL AREA
PER A#04-122968
N.I.S.
(E) STAFF RESTROOM
PER A#04-116732
(E) PORTABLE
PER A#04-122968
(E) BOYS RESTROOM
PER A#04-122968
(E) GIRLS RESTROOM
PER A#04-122968
(E) STAFF RESTROOM
PER A#04-122968
-9
-0
PR
OJ
EC
T
NU
MB
ER
DA
TE
RE
VI
SI
ON
RO
OF
T
ILE
R
EP
LA
CE
ME
NT
S . E
UC
LID
A
VE
, O
NT
AR
IO
, C A
EU
CL
ID
E
LE
ME
NT
AR
Y
SC
HO
OL
ON
TA
RI
O-
MO
NT
CL
AI
R
UN
IF
IE
D
SC
HO
OL
D
IS
TR
IC
T
PR
OJ
EC
T
ST
AT
US
DE
SC
RI
PT
IO
N:
PR
OJ
EC
T
ST
AT
US
PR
OJ
EC
T
DA
TE
PR
OJ
EC
T
IS
SU
ED
S
GH
A
RC
HI
TE
CT
S
IN
C.
A
LL
R
IG
HT
S
RE
SE
RV
ED
SE
AL
S:
CO
NS
UL
TA
NT
A-1.0
OV
ER
AL
L S
IT
E
PL
AN
A
ND
A
CC
ES
S
PA
TH
O F
TR
AV
EL
SCALE: 1" = 30' - 0"
OVERALL SITE PLAN 1
SEC.
SLOPE DOWN
SLOPE DOWN
EA
VE
EA
VE
RAKE
(E) PARAPET WALL (PIP)
RAKE TILES PER MANUFACTURER
INSTALLATION INSTRUCTIONS
GALV. SHEET METAL FLASHING - A -
SEE 8/A-9.0
A-9.0
NEW ROOF TILE AS PER SPEC.
6" WIDE x 4" TALL x 12" RETURN TILE PAN FLASHING
MINIMUM 24-GAUGE G90 GALVANIZED STEEL, ASTM A653.
PROVIDE CONTINUOUS COUNTER FLASHING:
4" x 5" MINIMUM 3" OVERLAP OVER PAN FLASHING.
MINIMUM 24-GAUGE G90 GALVANIZED STEEL
ROOF UNDERLAYMENT
EXISTING EXTERIOR PLASTER FINISH O/
WEATHER BARIER AND WIRE MESH
RAKE TILES AS PER MANUFACTURER INSTALLATION OVER
NAILERS SECURED TO ROOF W/ 8d NAILS AT 16" O.C.
EXISTING RIGID SHEATHING TO SUPPORT UNDERLAYMENT-
TONGUE & GROOVE (T & G) PLYWOOD TO REMAIN
(PROTECT IN PLACE)
(E) TONGUE AND GROOVE (T&G) SHEATHING
TO REMAIN (PROTECT IN PLACE)
(E) RAFTER, STRUCTURE TO REMAIN
(PROTECT IN PLACE)
(E) WALL TO REMAIN (PROTECT IN PLACE)
EXTEND ROOF UNDERLAYMENT A 1" MIN. OVER RAKE WALL
REMOVE A PORTION OF (E) PLASTER FINISH AND (E) FLAHSING. INSTALL
FLASHING, EXTEND (E) WEATHER BARRIER AND MESH O/ FLASHING.
PATCH AND REPAIR PLASTER FINISH TO MATCH EXISTING
6"
NOTES
KEY NOTES
1 (E) ROOFING TILES TO REMOVE AND DISPOSE OFF-SITE
2. (E) NON-CONSISTENT GUTTER TO REMOVE AND DISPOSE OFF-SITE
3. (E) ROOF EDGE WITHOUT GUTTER
4. (E) DETERIORATED 2X FASCIA WOOD BLOCKING TO BE REMOVED
AND DISPOSED OF OFF-SITE.
5. REMOVE ROOFING SYSTEM, SHEATHING, FRAMING, AND BEAMS.
6. NOT USED
7. NOT USED
8. NOT USED
9. (N) ROOF TILES AS PER DET. 14/ A-9.0
10. (N) GUTTER AS PER DET. 16/ A-9.0. ±50'-0"
11. (N) 2X FASCIA WOOD BLOCKING AS PER DET. 16/A-9.0. ±50'-0"
LEGEND
1. PROTECT EXISTING EQUIPMENT AND ROOFING SURFACES FOR
INSTALLATION OF NEW ROOFING TILES.
2. PROPERLY DISPOSE OF OLD ROOFING TILES, REMOVED ROOF
ASSEMBLIES, DOWNSPOUTS, RAILING, AND ALL OTHER DEMOLISHED
MATERIALS PER LOCAL CODES AND ORDINANCES.
(N) ROOF TILES
(E) ROOF TILES TO BE REMOVED
(E) ROOF TILES TO REMAIN
OVERHEAD ROOF RAFTERS
OVERHEAD ROOF BEAMS
COLUMNS
(N) GUTTER AS PER DET. 16/ A-9.0. ±50'-0"
(N) 2X FASCIA WOOD BLOCKING AS PER
DET. 16/A-9.0. ±50'-0"
(N) 2X FASCIA WOOD BLOCKING AS PER
DET. 16/A-9.0. ±50'-0"
(N) GUTTER AS PER DET. 16/ A-9.0. ±50'-0"
(N) GUTTER AS PER DET. 16/ A-9.0. ±50'-0"
A-6.0
A-5.0
RA
KE
VALLEY
EA
VE
EA
VE
EA
VE
EAVE
UPPER EAVE, TYP.
RAKE
UP
PE
R
EA
VE
UP
PE
R
EA
VE
UP
PE
R
EA
VE
VALLE
Y
RAKE @ WALL
RAKE
RAKE
EA
VE
-9
-0
PR
OJ
EC
T
NU
MB
ER
DA
TE
RE
VI
SI
ON
RO
OF
T
ILE
R
EP
LA
CE
ME
NT
S . E
UC
LID
A
VE
, O
NT
AR
IO
, C A
EU
CL
ID
E
LE
ME
NT
AR
Y
SC
HO
OL
ON
TA
RI
O-
MO
NT
CL
AI
R
UN
IF
IE
D
SC
HO
OL
D
IS
TR
IC
T
PR
OJ
EC
T
ST
AT
US
DE
SC
RI
PT
IO
N:
PR
OJ
EC
T
ST
AT
US
PR
OJ
EC
T
DA
TE
PR
OJ
EC
T
IS
SU
ED
S
GH
A
RC
HI
TE
CT
S
IN
C.
A
LL
R
IG
HT
S
RE
SE
RV
ED
SE
AL
S:
CO
NS
UL
TA
NT
SCALE: 1/16" = 1' - 0"
BUILDING 'A' - NEW ROOF TILE REPLACEMENT PLAN 1SCALE: 1/16" = 1' - 0"
BUILDING 'A' - DEMO ROOF TILE PLAN 2
SCALE: 1-1/2" = 1' - 0"
ENLARGED PLAN AND SECTION 3
A-5.0
BU
ILD
IN
G
'A
DE
MO
A
ND
N
EW
R
OO
F
PL
AN
(E) WOOD BEAM FOR REPAIR PHOTO (SEE DRAWING DETAIL 3/A-5.1)
BEAM REPAIR PER DETAIL 2/A-5.1
(E) WOOD BEAM FOR REPAIR01
A-01
A-05
A-11
A-10
A-09
A-01
A-06
A-02
A-07
A-08
A-03
A-04
A-6.0
FILL CHECK WITH SIKADUR-32 HI-MOD BY SIKA
3/4" LAG SCREWS @ BEAM WITH CHECK ONLY,
SPACING PER ELEVATION
1 1/2" MIN.
SECTION A
1/4 L
LAG SCREW
@ 9" O.C.
L = POST C.L. TO C.L.
1/2 L
LAG SCREW
@ 18" O.C.
1/4 L
LAG SCREW
@ 9" O.C.
(E) CRACK
3" 3"
A FIRST SCREW 3" FROM EDGE OF POST
ELEVATION
NOTE:
SEE ROOF FRAMING PLAN @ 1/A-5.1 FOR BEAMS REQUIRES REPAIR
2" M
IN
. B
EY
O
N D
C H
EC
K
(E) WOOD POST
(E) WOOD BEAM PER PLAN
(E) WOOD BEAM PER PLAN
(E) BEAM 01 - A01 (E) BEAM 04 - A04
(E) BEAM 07 - A07
(E) BEAM 02 - A02
(E) BEAM 08 - A08
(E) BEAM 03 - A03 (E) BEAM 06 - A06
(E) BEAM 09 - A09(E) BEAM 05 - A05
(E) BEAM 10 - A10
(E) BEAM 11 - A11
GENERAL NOTES - OBSERVED CRACKED BEAMS:
1. DURING THE SITE VISIT, A TOTAL OF ELEVEN (11) WOOD
BEAMS WERE OBSERVED WITH VISIBLE CRACKS ON ONE
SIDE.
2. BASED ON A VISUAL FIELD OBSERVATION, THE CRACKED
BEAMS ARE TO BE REPAIRED TO ENSURE THE LONG-TERM
STRUCTURAL INTEGRITY, DURABILITY, AND SERVICEABILITY
OF THE MEMBERS.
3. REPAIR THE CRACKED BEAMS PER DETAIL 2/A-5.1.
4. THE ATTACHED PHOTOGRAPHS DOCUMENT THE
OBSERVED CRACKING CONDITIONS AT THE TIME OF THE
SITE VISIT AND SERVE AS A RECORD OF THE EXISTING
CONDITIONS.
-9
-0
PR
OJ
EC
T
NU
MB
ER
DA
TE
RE
VI
SI
ON
RO
OF
T
ILE
R
EP
LA
CE
ME
NT
S . E
UC
LID
A
VE
, O
NT
AR
IO
, C A
EU
CL
ID
E
LE
ME
NT
AR
Y
SC
HO
OL
ON
TA
RI
O-
MO
NT
CL
AI
R
UN
IF
IE
D
SC
HO
OL
D
IS
TR
IC
T
PR
OJ
EC
T
ST
AT
US
DE
SC
RI
PT
IO
N:
PR
OJ
EC
T
ST
AT
US
PR
OJ
EC
T
DA
TE
PR
OJ
EC
T
IS
SU
ED
S
GH
A
RC
HI
TE
CT
S
IN
C.
A
LL
R
IG
HT
S
RE
SE
RV
ED
SE
AL
S:
CO
NS
UL
TA
NT
SCALE: 3/32" = 1' - 0"
BUILDING 'A' - ROOF FRAMING PLAN 1SCALE: N.T.S.
BEAM STRUCTURAL REINFORCMENT DETAILS 2
SCALE: N.T.S.
EXISTING BEAMS PHOTOS & CONDITIONS 3
A-5.1
BU
ILD
IN
G
'A
FR
AM
IN
G
PL
AN
A
ND
R
EI
NF
OR
CE
ME
NT
D
ET
A-9.0
A-9.0 15&16
A-6.1
A-6.1
SIM.
SIM.
A-9.0
PROVIDE NEW DOWNSPOUT AT LOCATIONS INDICATED TO
AVOID CONFLICT WITH EXISTING RAMP. SEE DET. 13/A-9.0
REMOVE AND DISPOSE OF THE EXISTING ROOF EXTENSION
OFF SITE.
REMOVE AND DISPOSE OF THE EXISTING DOWNSPOUTS
SUPPORTING THE ROOF EXTENSION OFF SITE.
PROVIDE NEW GUTTER ALONG THE EDGE OF ROOF EAVE,
PER DETAIL 16/A-9.0
PROVIDE NEW FASCIA, PER DETAIL 16/A-9.0
REMOVE AND DISPOSE OF THE EXISTING DOWNSPOUTS
SUPPORTING THE ROOF EXTENSION OFF SITE.
CUT, REMOVE, AND DISPOSE OF EXISTING METAL PIPE
POSTS OFF SITE AT 4" ABOVE THE HANDRAIL. CAP THE TOP
OF THE REMAINING POSTS WITH 3/4" METAL PLATE AND
GRIND SMOOTH ALL EDGES.
PROVIDE NEW GUTTER ALONG THE EDGE OF ROOF EAVE,
PER DETAIL SEE DET. 13/A-9.0
PROVIDE NEW FASCIA, PER DETAIL 16/A-9.0
PROVIDE NEW DOWNSPOUT AT LOCATIONS INDICATED TO
AVOID CONFLICT WITH EXISTING RAMP.
SEE DET. 13&17/A-09
CUT, REMOVE, AND DISPOSE OF EXISTING METAL PIPE
POSTS OFF SITE AT 4" ABOVE THE HANDRAIL. CAP THE TOP
OF THE REMAINING POSTS WITH 3/4" METAL PLATE AND
GRIND SMOOTH ALL EDGES.
REMOVE AND DISPOSE OF THE EXISTING ROOF EXTENSION
OFF SITE. PROTECT EXISTING ROOF RAFTERS IN PLACE. CUT
THE ROOF EXTENSION BEYOND THE RAFTERS
REMOVE AND DISPOSE OF THE EXISTING DOWNSPOUTS
SUPPORTING THE ROOF EXTENSION OFF SITE.
REMOVE AND DISPOSE OF THE EXISTING ROOF EXTENSION
OFF SITE. PROTECT ROOF RAFTERS IN PLACE.
REMOVE AND DISPOSE OF THE EXISTING DOWNSPOUTS
SUPPORTING THE ROOF EXTENSION OFF SITE.
CUT, REMOVE, AND DISPOSE OF EXISTING METAL PIPE POSTS
OFF SITE AT 4" ABOVE THE HANDRAIL. CAP THE TOP OF THE
REMAINING POSTS WITH 3/4" METAL PLATE AND GRIND
SMOOTH ALL EDGES.
-9
-0
PR
OJ
EC
T
NU
MB
ER
DA
TE
RE
VI
SI
ON
RO
OF
T
ILE
R
EP
LA
CE
ME
NT
S . E
UC
LID
A
VE
, O
NT
AR
IO
, C A
EU
CL
ID
E
LE
ME
NT
AR
Y
SC
HO
OL
ON
TA
RI
O-
MO
NT
CL
AI
R
UN
IF
IE
D
SC
HO
OL
D
IS
TR
IC
T
PR
OJ
EC
T
ST
AT
US
DE
SC
RI
PT
IO
N:
PR
OJ
EC
T
ST
AT
US
PR
OJ
EC
T
DA
TE
PR
OJ
EC
T
IS
SU
ED
S
GH
A
RC
HI
TE
CT
S
IN
C.
A
LL
R
IG
HT
S
RE
SE
RV
ED
SE
AL
S:
CO
NS
UL
TA
NT
SCALE: 1/8" = 1' - 0"
BUILDING 'A' - SECTION 1SCALE: N/A
NOT USED 4
SCALE: 1/8" = 1' - 0"
BUILDING 'A' - SECTION 1
SCALE: 1/8" = 1' - 0"
BUILDING 'A' - SECTION 1
SCALE: 1/8" = 1' - 0"
EXISTING ROOF EXTENSION REMOVAL DETAILS 5
A-6.0
BU
ILD
IN
G
'A
SE
CT
IO
NS
8' -2
10'-9" 1'-2"1'-2"
1' -0
8'
-2
10'-9" 1'-2"1'-2"
1' -0
3' -6
REMOVE EXISTING ROOF TILE AND
SUBSTRATES AND DISPOSE OUT
OFF-SITE
EXISTING METAL GUTTER AND
ATTACHMENTS TO REMAIN
(PROTECT IN PLACE). ADD OR
REPLACE PARTIAL GUTTER &
FASCIA WOOD BLOCK AS PER A-5.0
EXISTING STRUCTURAL BEAM TO
REMAIN (PROTECT IN PLACE).
REPAIR CHECKS ON VARIOUS
WOOD BEAMS AS PER A-5.1
EXISTING METAL PLATE
REPAIR CHECKS ON VARIOUS
WOOD BEAMS AS PER A-5.1
EXISTING STRUCTURAL COLUMN
TO REMAIN (PROTECT IN PLACE)
EXISTING
HANDRAIL/GUARDRAIL/RAMP TO
REMAIN (PROTECT IN PLACE)
EXISTING GRASS / LANDSCAPE TO
REMAIN (PROTECT IN PLACE)
NEW ROOF EDGE FLASHING
DETAIL 8/A-9.0
NEW ROOF TILES AS PER DETAIL
14/A-9.0
NEW OR EXISTING ROOF
GUTTER AS PER DETAIL
15&16/A-9.0
NEW OR EXISTING FASCIA
BOARD. SEE DETAIL 15&16/A-9.0
EXISTING STRUCTURAL PLATE
TO REMAIN (PROTECT IN PLACE)
EXISTING WOOD BEAM. TO
REMAIN (PROTECT IN PLACE)
EXISTING STRUCTURAL COLUMN
TO REMAIN (PROTECT IN PLACE)
REPAIR / PATCH AND PAINT ALL
SURFACE DAMAGES OF COLUMN
AND COLUMN HEAD AFTER NEW
BEAM INSTALLATION
REMOVE EXISTING ROOF TILE AND
SUBSTRATES AND DISPOSE OUT
OFF-SITE
EXISTING METAL GUTTER AND
ATTACHMENTS TO REMAIN
(PROTECT IN PLACE). ADD OR
REPLACE PARTIAL GUTTER &
FASCIA WOOD BLOCK AS PER A-5.0
REPAIR CHECKS ON VARIOUS
WOOD BEAMS AS PER A-5.1
EXISTING STRUCTURAL COLUMN
TO REMAIN (PROTECT IN PLACE)
EXISTING
HANDRAIL/GUARDRAIL/RAMP TO
REMAIN (PROTECT IN PLACE)
REMOVE EXISTING ROOF TILE AND
SUBSTRATES AND DISPOSE OUT
0FF-SITE
EXISTING METAL GUTTER AND
ATTACHMENTS TO REMAIN
(PROTECT IN PLACE). ADD OR
REPLACE PARTIAL GUTTER &
FASCIA WOOD BLOCK AS PER A-5.0
EXISTING STRUCTURAL BEAM TO
REMAIN (PROTECT IN PLACE)
EXISTING STRUCTURAL COLUMN
TO REMAIN (PROTECT IN PLACE)
EXISTING
HANDRAIL/GUARDRAIL/RAMP TO
REMAIN (PROTECT IN PLACE)
EXISTING GRASS / LANDSCAPE TO
REMAIN (PROTECT IN PLACE)
REMOVE EXISTING ROOF TILE AND
SUBSTRATES AND DISPOSE OUT
0FF-SITE
EXISTING METAL GUTTER AND
ATTACHMENTS TO REMAIN
(PROTECT IN PLACE). ADD OR
REPLACE PARTIAL GUTTER &
FASCIA WOOD BLOCK AS PER A-5.0
EXISTING STRUCTURAL BEAM TO
REMAIN (PROTECT IN PLACE)
EXISTING STRUCTURAL COLUMN
TO REMAIN (PROTECT IN PLACE)
EXISTING
HANDRAIL/GUARDRAIL/RAMP TO
REMAIN (PROTECT IN PLACE)
EXISTING GRASS / LANDSCAPE TO
REMAIN (PROTECT IN PLACE)
NEW ROOF EDGE FLASHING
DETAIL 8/A-9.0
NEW ROOF TILES AS PER DETAIL
14/A-9.0
NEW OR EXISTING ROOF
GUTTER AS PER DETAIL
15&16/A-9.0
NEW OR EXISTING FASCIA
BOARD. SEE DETAIL 15&16/A-9.0
EXISTING STRUCTURAL PLATE
TO REMAIN (PROTECT IN PLACE)
EXISTING WOOD BEAM. TO
REMAIN (PROTECT IN PLACE)
EXISTING STRUCTURAL COLUMN
TO REMAIN (PROTECT IN PLACE)
REPAIR / PATCH AND PAINT ALL
SURFACE DAMAGES OF COLUMN
AND COLUMN HEAD AFTER NEW
BEAM INSTALLATION
-9
-0
PR
OJ
EC
T
NU
MB
ER
DA
TE
RE
VI
SI
ON
RO
OF
T
ILE
R
EP
LA
CE
ME
NT
S . E
UC
LID
A
VE
, O
NT
AR
IO
, C A
EU
CL
ID
E
LE
ME
NT
AR
Y
SC
HO
OL
ON
TA
RI
O-
MO
NT
CL
AI
R
UN
IF
IE
D
SC
HO
OL
D
IS
TR
IC
T
PR
OJ
EC
T
ST
AT
US
DE
SC
RI
PT
IO
N:
PR
OJ
EC
T
ST
AT
US
PR
OJ
EC
T
DA
TE
PR
OJ
EC
T
IS
SU
ED
S
GH
A
RC
HI
TE
CT
S
IN
C.
A
LL
R
IG
HT
S
RE
SE
RV
ED
SE
AL
S:
CO
NS
UL
TA
NT
A-6.1
EN
LA
RG
ED
E
LE
VA
TI
ON
S
AN
D
DE
TA
ILS
SCALE: 3/8" = 1' - 0"
EXISTING DAMAGED BEAM ELEVATION 1
SCALE: 3/8" = 1' - 0"
EXISTING DAMAGED BEAM ELEVATION 2
SCALE: 3/8" = 1' - 0"
NEW REPLACED ROOF TILE ELEVATION 3
SCALE: 3/8" = 1' - 0"
BEAM REPLACEMENT AND ROOF TILE REPLACEMENT 4
INSPECTION: THE PROJECT INSPECTOR MUST PROVIDE CONTINUOUS INSPECTION OF THE
ATTACHMENT OF THE ROOF TILE. NO INSTALLATION OF ROOF TILES MAY BE STARTED WITHOUT
DSA-APPROVED PLANS AND DETAILS, INCLUDING ANY CONTRACTOR SUBSTITUTIONS OF ROOF
TILE SYSTEMS.
NOTE:
ANCHORAGE OF CLAY TILE SHALL COMPLY W/ CBC SEC. 1507.3, 1513 AND DSA IR 15-2. TILE SHALL BE INSTALLED IN
ACCORDANCE WITH CBC TABLE 1507.3.7. & CBC SECTION 1512.
FASTENERS: NAILS SHALL BE LONG ENOUGH TO PENETRATE INTO THE SHEATHING 3/4 INCH (19 MM). WHERE SHEATHING IS LESS THAN 3/4 INCH (19 MM) IN THICKNESS, NAILS SHALL BE DRIVEN INTO SUPPORTS, UNLESS NAILS WITH RING SHANKS ARE USED.ALL FASTENERS SHALL BE CORROSION RESISTANT AND FABRICATED OF COPPER, STAINLESS STEEL, OR BRASS, OR SHALL HAVE A HOT DIPPED GALVANIZED COATING NOT LESS THAN 1.0 OUNCE OF ZINC PER SQUARE FOOT (305 GM/M2).NAILS FOR SLATE SHINGLES AND CLAY OR CONCRETE TILE SHALL BE COPPER, BRASS OR STAINLESS STEEL WITH GAGE AND LENGTH PER COMMON FERROUS NAILS.
WIRE: WIRE FOR ATTACHING SLATE SHINGLES AND CLAY OR CONCRETE TILE SHALL BE COPPER, BRASS OR STAINLESS STEEL CAPABLE OF SUPPORTING FOUR TIMES THE WEIGHT OF TILE.WIRE SUPPORTING A SINGLE TILE OR SHINGLE SHALL NOT BE SMALLER THAN 1/16 INCH (1.6 MM) IN DIAMETER. CONTINUOUS WIRE TIES SUPPORTING MORE
THAN ONE TILE SHALL NOT BE SMALLER THAN 0.084 INCH (2 MM) IN DIAMETER.
CBC 1513.4
CLAY OR CONCRETE TILE SHALL BE INSTALLED IN ACCORDANCE WITH TABLE 1507.3.7 AND AS DESCRIBED HEREIN.
1. ON WOOD ROOFS OR ROOFS OF OTHER MATERIAL TO WHICH WOOD STRIPS ARE SECURED, EVERY COVER OR
TOP TILE WHEN FASTENED WITH NAILS SHALL BE NAILED DIRECTLY INTO 11/4 INCHES (32 MM) SOUND GRAIN SOFT WOOD STRIPS OF SUFFICIENT HEIGHT TO SUPPORT THE TILE. PAN OR BOTTOM TILES SHALL BE NAILED DIRECTLY TO THE ROOF SHEATHING OR TO WOOD STRIPS. WOOD STRIPS SHALL BE SECURED TO THE ROOF BY NAILS
SPACED NOT OVER 12 INCHES (305 MM) APART.
2. WHERE CONTINUOUS TIES OF TWISTED WIRE, INTERLOCKING WIRES OR METAL STRIPS EXTENDING FROM THE RIDGE TO EAVE ARE USED TO ATTACH TILE, THE TIES SHALL BE ATTACHED TO THE ROOF CONSTRUCTION AT THE RIDGE, EAVE AND AT INTERVALS NOT EXCEEDING 10 FEET 0 INCH (3048 MM) ON THE TIES WITHIN 2 FEET 0 INCH (610 MM) OF THE RAKE SHALL BE ATTACHED AT INTERVALS OF 5 FEET 0 INCH (1524 MM). ATTACHMENT FOR CONTINUOUS TIES SHALL BE NAILS, SCREWS STAPLES OR APPROVED CLIPS OF THE SAME MATERIAL AS THE TIES, AND SHALL NOT BE SUBJECTED TO WITHDRAWAL FORCES. ATTACHMENTS FOR CONTINUOUS TIES SHALL HAVE AN ALLOWABLE WORKING STRESS SHEAR RESISTANCE OF NOT LESS THAN TWICE THE DEAD WEIGHT OF THE TILE
TRIBUTARY TO THE ATTACHMENT, BUT NOT LESS THAN 300 POUNDS (136 KG).
3. TILE WITH PROJECTING ANCHOR LUGS AT THE BOTTOM OF THE TILES SHALL BE HELD IN POSITION BY MEANS OF 1- INCH BY 2-INCH (25MM BY 51MM) WOOD STRIPPING NAILED TO THE ROOF SHEATHING OVER THE UNDERLAY.
4. CLAY OR CONCRETE TILE ON ROOFS WITH SLOPES EXCEEDING 24 UNITS VERTICAL IN 12 UNITS HORIZONTAL (200 PERCENT SLOPE) SHALL BE ATTACHED AS REQUIRED FOR VENEER IN CHAPTER 14. THE NOSE OF ALL TILES SHALL
BE SECURELY FASTENED.
5. CLAY OR CONCRETE TILE SHALL HAVE A MINIMUM OF TWO FASTENERS PER TILE. TILES THAT ARE 8 INCHES (203 MM) IN WIDTH OR LESS ARE PERMITTED TO BE FASTENED AT THE CENTER OF THE HEAD WITH ONE FASTENER
PER TILE.
6. INTERLOCKING CLAY OR CONCRETE TILE SHALL HAVE A MINIMUM OF ONE NAIL NEAR CENTER OF HEAD OR TWO
WIRE TIES PER TILE.
TWISTED TIE WIRE LOOP SYSTEM
STORM-LOCK TILE FASTENER /
TYLE-TYE TWISTED SYSTEM W/ DECK
ANCHOR (USE 2-10d
RING SHANK ROOFING NAILS TO
SECURE TO ROOF DECK. BY STORM
LOCK, IAMPO REPORT UES #444
www.storm-locktilefasteners.com/twisted/index.html#
OR EQUAL
WIND HOOK
DISTANCE BETWEEN TILES
CODE APPROVED
FASTENTING SYSTEM
DECK ANCHOR
COVER TILE
BOOSTER TILE
BIRD STOP
ROOF DECK
UNDERLAYMENT
BIRD STOP
ROOF TILE
EXISTING WOOD BEAM AND
RAFTERS PROTECT IN PLACE
EXISTING T&G WOOD SUBSTRATE
END ROW WOOD NAILING STRIP
NEW 2x4 RO-SAWN REDWOOD
FASCIA PAINT TO MATCH
ROOF UNDERLAYMENT - EXTEND
1" MIN OVER RAKE
(E) RAFTER. STRUCTURE TO
REMAIN (PROTECT IN PLACE)
RAKE TILES AS PER
MANUFACTURER INSTALLATION
REMOVE AND DISPOSE OF EXISTING DOWNSPOUT,
INCLUDING TWO ELBOWS AND ANGLED ARM FROM
GUTTER TO EXISTING VERTICAL DOWNSPOUT.
REPLACE WITH NEW DOWNSPOUT ASSEMBLY PER
DETAIL 15/A-9.0.
(E) STRUCTURAL CONCRETE COLUMN TO REMAIN
(PROTECT IN PLACE)
(E) MAIN WOOD BEAM TO REMAIN (PROTECT IN PLACE)
A-9.0
EXISTING RIGID SHEATHING TO SUPPORT
UNDERLAYMENT MAY TONGUE & GROOVE
(T & G) PLYWOOD TO REMAIN
(PROTECT IN PLACE)
A-9.0
A-9.0
GUTTER SHEET METAL SIMILAR TO EXISTING -
24-GAUGE GALVANIZED STEEL (G90). TYPE-K PRE
FINISHED. WITH UNIVERSAL STEEL CLINCHER BANDS
(COLOR-MATCHED (E)). JOINTS SEALED WITH
MANUFACTURER-APPROVED SEALANT. AT ENTIRE
PERIMETER OF ROOF. SEE DET-16/A-9.0
(E) DOWN SPOUT TO REMAIN (PROTECT IN PLACE)
ROOF EDGE WITH NEW GUTTER
1/
2"
1/ 2"
3"
5°
7"
1/ 2"
2'-2 1/2"
1'-2"
1'-2"
3"
ROOF EDGE WITH NEW GUTTER
1 1/2"
1"
4 1/2"
VIF
3"
4" VI
F 1"
4 1/4"
3/4"
GUTTER SHEET METAL SIMILAR TO EXISTING - 24-GAUGE
GALVANIZED STEEL (G90). TYPE-K PRE FINISHED. WITH UNIVERSAL
STEEL CLINCHER BANDS (COLOR-MATCHED (E)).
JOINTS SEALED WITH MANUFACTURER-APPROVED SEALANT.
NEW ROOF PRIMARY WATERPROOFING MEMBRANE
UNDERPAYMENT. SEE DET. 13/A-9.0
NOTE:
PROVIDE 24-GAUGE PREFINISHED G90 GALVANIZED STEEL GUTTERS AND DRIP EDGE
FLASHING WITH FACTORY-APPLIED PVDF FINISH. FABRICATE AND INSTALL IN
ACCORDANCE WITH SMACNA STANDARDS, NRCA ROOFING MANUAL,
MANUFACTURER'S RECOMMENDATIONS, AND PROJECT SPECIFICATIONS.
COLOR TO MATCH ADJACENT ROOF TRIM.
BIRD STOP CLOSURE (EAVE CLOSURE) - FORMED GALVANIZED STEEL, MINIMUM
26-GAUGE G90. MANUFACTURER'S STANDARD PROFILE COMPATIBLE WITH THE
ROOF TILE. CONTINUOUS AT ALL EAVES.
ALLOWING DRAINAGE AND VENTILATION AS REQUIRED.
MAINTAIN ALIGNMENT WITH STARTER COURSE.
OR
PROVIDE THE ROOF TILE MANUFACTURER'S STANDARD EAVE CLOSURE/BIRD
STOP SYSTEM COMPATIBLE WITH THE SELECTED TILE PROFILE.
SECURE TO THE ROOF DECK OR EAVE FLASHING USING
CORROSION-RESISTANT FASTENERS.
NEW ROOF TILE AS PER MANUFACTURER AND DETAIL 14/A-9.0
(2) 16d TO EACH ROOF JOIST
EXISTING 2x6 T&G WOOD PANEL
NEW 2x4 RO-SAWN REDWOOD
FASCIA WITH SOLID BODY STAIN
EXISTING WOOD BEAM AND
RAFTERS PROTECT IN PLACE
NEW ROOF TILE AS PER SPEC.
CEMENT MORTAR AT ROOF TILE FIRST ROW
EXISTING EXTERIOR PLASTER FINISH O/
WEATHER BARRIER AND WIRE MESH
TILE TO HEADWALL
6"
REMOVE A PORTION OF (E) PLASTER FINISH AND (E) FLAHSING. INSTALL
FLASHING, EXTEND (E) WEATHER BARRIER AND MESH O/ FLASHING.
PATCH AND REPAIR PLASTER FINISH TO MATCH EXISTING
4" WIDE x 4" TALL FLASHING O/ ROOF TILE
MINIMUM 24-GAUGE G90 GALVANIZED STEEL, ASTM A653.
PROVIDE CONTINUOUS COUNTER FLASHING:
4" x 5" MINIMUM 3" OVERLAP OVER FLASHING. MINIMUM
24-GAUGE G90 GALVANIZED STEEL
ROOF UNDERLAYMENT
EXISTING T&G SHEATHING
4"
NOTE:
CONNECT NEW DOWNSPOUT TO EXISTING
UNDERGROUND STORM DRAIN LINE,
WHERE AVAILABLE. OTHERWISE, PROVIDE
SPLASH BLOCKS AS APPROPRIATE FOR
SITE CONDITIONS.
-9
-0
PR
OJ
EC
T
NU
MB
ER
DA
TE
RE
VI
SI
ON
RO
OF
T
ILE
R
EP
LA
CE
ME
NT
S . E
UC
LID
A
VE
, O
NT
AR
IO
, C A
EU
CL
ID
E
LE
ME
NT
AR
Y
SC
HO
OL
ON
TA
RI
O-
MO
NT
CL
AI
R
UN
IF
IE
D
SC
HO
OL
D
IS
TR
IC
T
PR
OJ
EC
T
ST
AT
US
DE
SC
RI
PT
IO
N:
PR
OJ
EC
T
ST
AT
US
PR
OJ
EC
T
DA
TE
PR
OJ
EC
T
IS
SU
ED
S
GH
A
RC
HI
TE
CT
S
IN
C.
A
LL
R
IG
HT
S
RE
SE
RV
ED
SE
AL
S:
CO
NS
UL
TA
NT
SCALE: 1-1/2" = 1' - 0"
WALL SECTION 1 A-9.0
W
AL
L S
EC
TI
ON
S
AN
D
DE
TA
ILS
SCALE: 3/4" = 1' - 0"
TILE ANCHOR SYSTEM 14
SCALE: 3" = 1' - 0"
EXISTING DOWNSPOUT SECTION TO BE REMOVED AND REPLACED WITH NEW 15
SCALE: 6" = 1' - 0"
ROOF EDGE WITH NEW GUTTER 16 SCALE: 3" = 1' - 0"
ROOF TILE FLASHING AT WALL 8 SCALE: N.T.S.
NOT USED 4
SCALE: 3/4" = 1' - 0"
DOWN SPOUT HIDDEN STRAP 13SCALE: 3/4" = 1' - 0"
PRE-CAST CONCRETE SPLASH BLOCK 17
AutoCAD SHX Text NOTES: 1- REMOVE AND DISPOSE OF EXISTING DOWNSPOUT, INCLUDING TWO ELBOWS AND ANGLED ARM FROM GUTTER TO EXISTING VERTICAL DOWNSPOUT. REPLACE WITH NEW DOWNSPOUT ASSEMBLY. 2- 24 GA. GALVANIZED SHEET METAL; PRIME AND PAINT TO MATCH EXISTING DOWN SPOUTS. 3- VERIFY ALL DIMENSIONS IN FIELD
File details come from the government source that posted it. Updated .