1-Euclid Playground DD Progress Drawings 261111.pdf

PDF 3 MB Posted

Attached to
Euclid & Monte Vista LLB
Solicitation number
C-267-523
Issued by
San Bernardino County, California

About this file

This file contains progress drawings for the Euclid Playground project, which is part of a larger capital improvement initiative at Euclid Elementary School in California. The drawings document the design development for the Kindergarten Playground Installation component of the Euclid Elementary School Basement Classroom Conversion, Kindergarten Playground Installation, Courtyard Roof Tile Replacement, and Artificial Turf Playfield Installation Projects. The progress drawings illustrate site plans, layout configurations, equipment specifications, and design details for the playground installation to support the kindergarten program at the elementary school facility.

The drawing set serves as construction documentation for the playground installation work and reflects the design phase progression for this component of the multi-phase school improvement project. This file represents preliminary design documentation and would be referenced during the bidding process and subsequent construction administration phases as contractors develop detailed pricing and construction methodologies for the playground installation work at Euclid Elementary School.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CODE AND STANDARDS

APPLICABLE CODES

• 2025 CALIFORNIA ADMINISTRATIVE CODE (CAC), PART 1, TITLE 24 CCR

• 2025 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 CCR

• 2025 CALIFORNIA ELECTRICAL CODE (CEC) , PART 3, TITLE 24 CCR

• 2025 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 CCR

• 2025 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 CCR

• 2025 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 CCR

• 2025 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 CCR

• 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11, TITLE 24 CCR

• 2025 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 CCR

• TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS

APPLICABLE STANDARDS

FOR A LIST OF APPLICABLE STANDARDS, INCLUDING CALIFORNIA AMENDMENTS TO THE NFPA STANDARDS, REFER TO CBC CHAPTER 35 AND CFC CHAPTER 80

SGH STD DTL - 11/5/2025

1. ALL WORK SHALL CONFORM TO TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) PARTS 1 TO 6, 9 AND 12.

2. FABRICATION AND INSTALLATION OF DEFERRED SUBMITTAL ITEMS SHALL NOT BE STARTED UNTIL CONTRACTOR’S DRAWINGS, SPECIFICATIONS, AND ENGINEERING CALCULATIONS FOR THE ACTUAL SYSTEMS TO BE INSTALLED HAVE BEEN ACCEPTED AND SIGNED BY THE ARCHITECT OR STRUCTURAL ENGINEER AND APPROVED BY THE DSA. LIST DEFERRED SUBMITTAL ITEMS FOR THIS PROJECT.

3. CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY AN ADDENDUM OR A CONSTRUCTION CHANGED DOCUMENT (CCD) APPROVED BY THE DIVISION OF THE STATE ARCHITECT, AS

REQUIRED BY SECTION 4-338, PART 1, TITLE 24, CCR.

4. ALL SUBSTITUTIONS AFFECTING DSA REGULATED ITEMS SHALL BE CONSIDERED AS A CONSTRUCTION CHANGE DOCUMENT (CCD) OR ADDENDA, AND SHALL BE APPROVED BY DSA PRIOR TO FABRICATION AND INSTALLATION SECTION 4-338, PART 1, TITLE 24, CCR. SUBSTITUTIONS SHALL BE FOR ANY MATERIAL, SYSTEM OR PRODUCT THAT WOULD OTHERWISE BE REGULATED BY DSA.

5. A “DSA CERTIFIED” CLASS 3 PROJECT INSPECTOR EMPLOYED BY THE DISTRICT (OWNER) AND APPROVED BY THE DSA SHALL PROVIDE CONTINUOUS INSPECTION OF THE WORK. THE DUTIES OF THE INSPECTOR ARE

DEFINED IN SECTION 4-342, PART 1, TITLE 24, CCR.

6. A DSA ACCEPTED TESTING LABORATORY DIRECTLY EMPLOYED BY THE DISTRICT (OWNER) SHALL CONDUCT

ALL THE REQUIRED TESTS AND INSPECTIONS FOR THE PROJECT.

7. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS THAT THE WORK OF THE ALTERATION, REHABILITATION OR RECONSTRUCTION IS TO BE IN ACCORDANCE WITH TITLE 24, CCR. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NON-COMPLYING CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH TITLE 24, CCR, A CONSTRUCTION CHANGE DOCUMENT (CCD), OR A SEPARATE SET OF PLANS AND SPECIFICATIONS, DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY DSA BEFORE PROCEEDING WITH THE WORK. (SECTION 4-317(C), PART 1, TITLE 24, CCR).

8. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND ENVIRONMENTAL

HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES.

9. A COPY OF CCR TITLE 24, PARTS 1-6, 9 AND 12 SHALL BE KEPT ON SITE DURING CONSTRUCTION.

10. A COPY OF THE APPROVED DRAWINGS, SPECIFICATIONS, ADDENDUMS AND CONSTRUCTION CHANGE

DOCUMENTS SHALL BE KEPT ON SITE DURING CONSTRUCTION.

11. FIRE SAFETY DURING DEMOLITION AND CONSTRUCTION SHALL COMPLY WITH CBC CHAPTER 33 AND CFC

CHAPTER 33

12. THE CONTRACTOR SHALL PROVIDE CLEAN, SANITARY, TEMPORARY TOILET FACILITIES FOR THE CONSTRUCTION PERSONNEL. UNDER NO CIRCUMSTANCES SHALL CONSTRUCTION PERSONNEL BE ALLOWED TO UTILIZE THE PERMANENT SITE FACILITIES. ALL TEMPORARY FACILITIES SHALL BE REMOVED FROM THE

SITE AT THE CONCLUSION OF CONSTRUCTION.

13. ALL ADDENDA MUST BE SIGNED BY ARCHITECT AND APPROVED BY DSA. (CAC, SECTION 4-338 (B)).

14. CONSTRUCTION CHANGE DOCUMENTS (CAC, SECTION 4-338(C)) MUST BE SIGNED BY ALL THE FOLLOWING:

• A/E OF RECORD

• STRUCTURAL ENGINEER (WHEN APPLICABLE)

• DELEGATED PROFESSIONAL ENGINEER (WHEN APPLICABLE)

• DSA

15. THE PROJECT INSPECTOR AND TESTING LAB MUST BE EMPLOYED BY THE OWNER AND APPROVED BY ALL

OF THE FOLLOWING:

• A/E OF RECORD

• STRUCTURAL ENGINEER (WHEN APPLICABLE)

• DSA

DSA REGULATIONS NOTES

SGH STD DTL - 11/5/2025

CLIENT:

NAME:

ADDRESS:

PHONE:

CONTACT:

EMAIL:

PROJECT DIRECTORY

ONTARIO-MONTCLAIR SCHOOL DISTRICT

950 W D STREET

ONTARIO, CA, 91762

909-418-6369

BROOKE MURRAY

BROOKE.MURRAY@OMSD.NET

CIVIL:

NAME:

ADDRESS:

PHONE:

CONTACT:

EMAIL:

FPL AND ASSOCIATES, INC.

30 CORPORATE PARK, SUITE 401

IRVINE, CA, 92606

949-252-1688

RON CANEDY

RON.CANEDY@FPLANDASSOCIATES.COM

LANDSCAPE:

NAME:

ADDRESS:

PHONE:

CONTACT:

EMAIL:

SILVER BAR STUDIO

P.O. BOX 5008-373

MARISPOSA, CA 95338

714-928-5107

CRAIG DUNCAN

CRAIG@SILVERBARSTUDIO.COM

ARCHITECT:

NAME:

ADDRESS:

PHONE:

CONTACT:

EMAIL:

SGH ARCHITECTS

160 VIA VERDE, SUITE 210

SAN DIMAS, CA, 91773

909-201-0045

XIANG LIU

XLIU@SGHARCH.COM

SGH STD DTL - 11/5/2025

PROJECT SCOPE OF WORK CONSIST OF:

PROJECT SCOPE OF WORK

REMOVING THE EXISTING NATURAL TURF AND THE NON-ADA COMPLIANT RAMP AND CONSTRUCTING

A TK PLAYGROUND WITHIN THE COURTYARD. THE TK PLAYGROUND WILL INCLUDE PLAYGROUND

EQUIPMENT, SYNTHETIC PLAYGRASS, AND RUBBERIZED SURFACING.

VICINITY MAP

PROJECT LOCATION

SHEET INDEXSTATEMENT OF GENERAL CONFORMANCE

APPLICATION No.:

THE DRAWINGS IDENTIFIED AS FOLLOWS:

HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND AUTHORIZED TO PREPARE SUCH DRAWINGS (PLANS) IN THIS STATE. THEY HAVE BEEN EXAMINED BY ME FOR:

1. DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA

CODE OF REGULATORS AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND

2. COORDINATION WITH MY DRAWINGS (PLANS) AND SPECIFICATIONS AND IS ACCEPTABLE FOR

INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT.

PER TITLE 24, PART 1, SECTION 4-316(B): THIS STATEMENT OF GENERAL CONFORMANCE SHALL NOT BE CONSTRUED AS RELIEVING ME OF MY RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER SECTIONS 17302 AND 81138 OF THE EDUCATION CODE AND SECTIONS 4-336, 4-341 AND 4-344 OF TITLE 24, PART 1.

SIGNATURE

PRINT NAME LICENSE NUMBER EXPIRATION DATE

ALL DRAWING SHEETS INCLUDED IN THIS SET NOT BEARING MY STAMP AND SIGNATUREX

DRAWING SHEETS DENOTED IN THE SHEET INDEX AS FOLLOWS:

DRAWING SHEETS INCLUDED UNDER THE FOLLOWING PC APPROVAL(S):

DATE

FILE No. :

04-125930

36-46

12 / 10 / 2026

MICHAEL STEPHENS C 26450 05 / 31 / 2027

XX-XXXXXX XX-XXXXXX

SGH STD DTL - 11/5/2025

THE CONTRACTOR SHALL PROVIDE TO THE ARCHITECT, WITHING TEN (10) CALENDAR DAYS FOLLOWING THE CONTRACTOR'S RECEIPT OF THE NOTICE TO PROCEED, A WRITTEN SITE SAFETY PLAN ON THE CONTRACTOR'S LETTERHEAD AND SIGNED BY THE CONTRACTOR'S RESPONSIBLE MANAGING OFFICER (RMO), IN COMPLIANCE WITH THE CURRENT AND ADOPTED CALIFORNIA FIRE CODE SECTION 3303.1.1 AS

WELL AS DSA BU 24-05.

SITE SAFETY PLANS SHALL INCLUDE THE FOLLOWING AS APPLICABLE (THE LIST IS NOT EXHAUSTIVE OR

COMPREHENSIVE, AND IS ONLY PROVIDED FOR CONTRACTOR CONVENIENCE):

1. NAME AND CONTACT INFORMATION OF SITE SAFETY DIRECTOR.

2. DOCUMENTATION OF THE TRAINING OF THE SITE SAFETY DIRECTOR AND FIRE WATCH PERSONNEL.

3. PROCEDURES FOR REPORTING EMERGENCIES.

4. FIRE DEPARTMENT VEHICLE ACCESS ROUTES.

5. LOCATION OF FIRE PROTECTION EQUIPMENT, INCLUDING PORTABLE FIRE EXTINGUISHERS,

STANDPIPES, FIRE DEPARTMENT CONNECTIONS AND FIRE HYDRANTS.

6. SMOKING AND COOKING POLICIES, DESIGNATED AREAS TO BE USED WHERE APPROVED, AND

SIGNAGE LOCATIONS IN ACCORDANCE WITH SECTION 3305.8.

7. LOCATION AND SAFETY CONSIDERATIONS FOR TEMPORARY HEATING EQUIPMENT.

8. HOT WORK PERMIT PLAN.

9. PLANS FOR CONTROL OF COMBUSTIBLE WASTE MATERIAL.

10. LOCATIONS AND METHODS FOR STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

AND OTHER HAZARDOUS MATERIALS.

11. PROVISIONS FOR SITE SECURITY.

12. CHANGES THAT AFFECT THIS PLAN.

13. OTHER SITE-SPECIFIC INFORMATION REQUIRED BY THE FIRE CODE OFFICIAL.GUARD POSTS OR

OTHER APPROVED MEANS SHALL COMPLY WITH SECTION 312. CFC 507.5.6

SITE SAFETY PLAN

GENERAL

G0.01 TITLE SHEET

G0.02 SYMBOLS AND ABBREVIATIONS

G1.11 SITE PLAN - ACCESSIBILITY SITE PLAN

CIVIL

C1.01 SHEET NAME

C2.01 SHEET NAME

C3.01 SHEET NAME

C4.01 SHEET NAME

C5.01 SHEET NAME

C6.01 SHEET NAME

C7.01 SHEET NAME

LANDSCAPE

L1.01 SHEET NAME

L2.01 SHEET NAME

L3.01 SHEET NAME

L4.01 SHEET NAME

L5.01 SHEET NAME

L6.01 SHEET NAME

L7.01 SHEET NAME

ARCHITECTURAL

A1.01 SITE PLAN - DEMOLITION

A1.02 SITE PLAN - ENLRAGED DEMOLITION

A1.11 SITE PLAN - OVERALL

* FOR ALL DRAWINGS MARKED WITH AN ASTERISK, REFER TO

"STATEMENT OF GENERAL CONFORMANCE" ON COVER SHEET G0.00

TOTAL

P R

O

JE

C T

N U

M B

E R

D A

T E

D

E

LT

A

D E

S C

R

IP

T

IO

N

P R

O

JE

C T

S T

A T

U S

S H

E E

T

IS

S U

E D

S G

H A

R C

H

IT

E C

T S

IN

C

A

LL

R

IG

H

T S

R E

S E

R V

E D

S E

A

LS

C

O N

S U

LT

A

N T

A# 04-125930

/9

/2

4:

:1

P

M C

:\U se rs \x liu \D oc um en ts

\E

LA

_O M

S D

_T K

_K _P la yg ro un d_ R

C

C _x liu Z

V V

2Q .r vt

-9

-0

T

IT

LE

S

H E

E T

G0.01

E U

C

LI

D L

A N

G U

A G

E A

C A

D E

M Y

T

K P

LA

Y

G R

O U

N D

S E

U C

L

ID

A V

E

O N

T A

R

IO

C

A

O N

T A

R

IO

-M O

N T

C L A

IR

S

C H

O O

L D

IS

T

R

IC

T

D

ES

IG

N

D

EV

EL

O

P M

EN

T

S H

T -S he et

I ss ue D at e

ONTARIO-MONTCLAIR SCHOOL DISTRICT

EUCLID LANGUAGE ACADEMY -

TK PLAYGROUND

1120 S EUCLID AVE, ONTARIO, CA 91762

DESIGN DEVELOPMENT

NORTH

" 20

PATH OF TRAVEL NOTES:

1. ACCESSIBLE PATH OF TRAVEL:

ACCESSIBLE PATH OF TRAVEL AS INDICATED ON PLANS IS A BARRIER FREE ACCESS ROUTE WITHOUT AN ABRUPT LEVEL CHANGES EXCEEDING 1/2" IF BEVELED AT 1:2 MAXIMUM SLOPE OR VERTICAL LEVEL CHANGES NOT EXCEEDING 1/4" MAXIMUM AND AT LEAST 48" IN WIDTH. SURFACE IS STABLE, FIRM, AND SLIP RESISTANT. CROSS SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5% UNLESS OTHERWISE INDICATED. ACCESSIBLE PATH OF TRAVEL SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM WALL ABOVE 27" AND LESS THAN 80". ARCHITECT SHALL VERIFY THAT THERE ARE NO

BARRIERS IN THE PATH OF TRAVEL.

2. DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE STATEMENT:

THE POT IDENTIFIED IN THESE CONSTRUCTION DOCUMENTS IS COMPLIANT WITH THE CURRENT

CALIFORNIA BUILDING CODE ACCESSIBILITY PROVISIONS FOR PATH OF TRAVEL REQUIREMENTS FOR ALTERATIONS AND STRUCTURAL REPAIRS. AS PART OF THE DESIGN OF THIS PROJECT, THE POT WAS EXAMINED AND ANY ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WERE DETERMINED TO BE NON COMPLIANT 1) HAVE BEEN IDENTIFIED AND 2) THE CORRECTIVE WORK NECESSARY TO BRING THEM INTO COMPLIANCE HAS BEEN INCLUDED WITHIN THE SCOPE OF THIS PROJECT'S WORK THROUGH DETAILS, DRAWINGS, AND SPECIFICATIONS INCORPORATED INTO THESE CONSTRUCTION DOCUMENTS.

ANY NONCOMPLIANT, COMPONENTS OR PORTIONS OF THE POT THAT WILL NOT BE CORRECTED BY THIS PROJECT BASED ON VALUATION THRESHOLD LIMITATIONS OR A FINDING OF UNREASONABLE HARDSHIP

ARE SO INDICATED IN THESE CONSTRUCTION DOCUMENTS.

3. DURING CONSTRUCTION, IF POT ITEMS WITHIN THE SCOPE OF THE PROJECT REPRESENTED AS CODE COMPLIANT ARE FOUND TO BE NONCONFORMING BEYOND REASONABLE CONSTRUCTION TOLERANCES, THEY SHALL BE BROUGHT INTO COMPLIANCE WITH THE CBC AS PART OF THIS PROJECT BY MEANS OF A

"CONSTRUCTION CHANGE DOCUMENT"

4. GATES IN THE ACCESSIBLE PATH OF TRAVEL SHALL COMPLY WITH ALL DOOR REQUIREMENTS STATED IN CBC SECTION 1010 AND 11B-404 FOR DOOR WIDTH, CLEARANCE, LANDINGS, DOOR HARDWARE, EXIT

DEVICE, DOOR OPERATING FORCE AND SURFACES.

5. EXISTING PATH-OF TRAVEL FROM LIMITS OF PROPOSED PROJECT TO THE EXISTING PUBLIC RIGHT- OF-WAY CONDITIONS WERE EXAMINED AND FOUND COMPLIANT WITH THE CURRENT CODE REQUIREMENTS IN THE

FIELD BY ARCHITECT OF RECORD ON AUGUST 4, 2026, INCLUDING:

• SLOPE AND CROSS SLOPE OF EXISTING RAMPS ALONG THE P.O.T

• HANDRAILS AND EDGE PROTECTION AT RAMPS ALONG P.O.T

• LEVEL LANDINGS AT RAMPS ALONG THE P.O.T

• CHANGES IN LEVEL AT ALL SIDEWALKS ALONG P.O.T

PATH OF TRAVEL LEGEND:

PATH OF TRAVEL STATION MARKER

X.X%

X.X%

X.X%

X.X%

CROSS SLOPE

RUNNING SLOPE

PERCENTAGE INDICATED

REPRESENTS THE HIGH

END OF THE SLOPE

ACCESSIBLE PATH OF TRAVEL

EXISTING PATH OF TRAVEL A#04-125769

**ACCESSIBLE PATH OF TRAVEL VERIFIED IN FIELD WITH SMART LEVEL ON AUGUST 4, 2026 - RUNNING SLOPE ALONG (E) PATH OF TRAVEL DO NOT EXCEED 4.8% AND CROSS SLOPES DO NOT EXCEED 2.0%.

PLEASE REFER TO "PATH OF TRAVEL" NOTES INCLUDED ON THIS SHEET FOR ADDITIONAL INFORMATION.

(E) RAMP

(E) RAMP RUN

(E) LANDING

ACCESSIBILITY CLEARANCES

60" DIA. ACCESSIBLE

TURN AROUND

PROPOSED PATH OF TRAVEL

(E) RESTROOMS

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E) P2 PORTABLE

A#04-103526

N.I.C.

(E) P3 PORTABLE

A#04-103526

N.I.C.

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E) MULTI-PURPOSE ROOM

A#04-106275

N.I.C.

(E) PLAYGROUND

N.I.C.

B E L M O N T S T R E E T

P A

L M

A V

E

R A L S T O N S T R E E T

E U

C L

I D

E N

U E

(E) P1 PORTABLE

A#04-122968

N.I.C.

(E) SAFE DISPERSAL AREA

A#04-117377

(E) SAFE DISPERSAL AREA

A#04-122968

(E) DRINKING FOUNTAIN

A# 04-116267

V A

N

N O

P

R K

I N

G

(E) BLDG A

(E) GIRLS RR

A# 04-116732

(E) BOYS RR

A# 04-116732

(E) STAFF

UNISEX

A# 04-116732

A# 2710 A# 60455 A# 04-101953 A# 04-116732

B

G

U

0.5%

1.8%

0.4%

3.4%

0.3%

0.7%

0.5%

0.2%

0.3% 0.4%

0.6%

0.2%

0.2%

0.4%

0.4%

0.4%

KEYNOTES

DESCRIPTION

P R

O

JE

C T

N U

M B

E R

D A

T E

D

E

LT

A

D E

S C

R

IP

T

IO

N

P R

O

JE

C T

S T

A T

U S

S H

E E

T

IS

S U

E D

S G

H A

R C

H

IT

E C

T S

IN

C

A

LL

R

IG

H

T S

R E

S E

R V

E D

S E

A

LS

C

O N

S U

LT

A

N T

A# 04-125930

/9

/2

4:

:2

P

M C

:\U se rs \x liu \D oc um en ts

\E

LA

_O M

S D

_T K

_K _P la yg ro un d_ R

C

C _x liu Z

V V

2Q .r vt

-9

-0

S

IT

E P

LA

N

A

C C

E S

S

IB

IL

IT

Y S

IT

E

P

LA

N

G1.11

E U

C

LI

D L

A N

G U

A G

E A

C A

D E

M Y

T

K P

LA

Y

G R

O U

N D

S E

U C

L

ID

A V

E

O N

T A

R

IO

C

A

O N

T A

R

IO

-M O

N T

C L A

IR

S

C H

O O

L D

IS

T

R

IC

T

D

ES

IG

N

D

EV

EL

O

P M

EN

T

/1

6/

DESIGN DEVELOPMENT

:SCALE1" = 20'-0"

SITE PLAN - ACCESSIBILITY

SITE PLAN LEGEND

PROPERTY LINE

LIMIT/SCOPE OF WORK

(E) RESTROOMS, A#04-116732

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E) P2 PORTABLE

A#04-103526

N.I.C.

(E) P3 PORTABLE

A#04-103526

N.I.C.

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E

P O

R T

A B

LE

A #0

4-

N .I.

C

(E) MULTI-PURPOSE ROOM

A#04-106275

N.I.C.

(E) PLAYGROUND

N.I.C.

B E L M O N T S T R E E T

P A

L M

E

R A L S T O N S T R E E T

E U

C L

I D

E N

U E

(E) P1 PORTABLE

A#04-122968

N.I.C.

(E) SAFE DISPERSAL AREA

A#04-117377

(E) SAFE DISPERSAL AREA

A#04-122968

(E) DRINKING FOUNTAIN

A# 04-116267

V A

N

N O

P

R K

I N

G

(E) BLDG A

(E) GIRLS RR

A# 04-116732

(E) BOYS RR

A# 04-116732

(E) STAFF

UNISEX

A# 04-116732

A# 2710 A# 60455 A# 04-101953 A# 04-116732

B

G

U

A1.31

P R

O

JE

C T

N U

M B

E R

D A

T E

D

E

LT

A

D E

S C

R

IP

T

IO

N

P R

O

JE

C T

S T

A T

U S

S H

E E

T

IS

S U

E D

S G

H A

R C

H

IT

E C

T S

IN

C

A

LL

R

IG

H

T S

R E

S E

R V

E D

S E

A

LS

C

O N

S U

LT

A

N T

A# 04-125930

/9

/2

4:

:2

P

M C

:\U se rs \x liu \D oc um en ts

\E

LA

_O M

S D

_T K

_K _P la yg ro un d_ R

C

C _x liu Z

V V

2Q .r vt

-9

-0

S

IT

E P

LA

N

O

V E

R A

LL

A1.11

E U

C

LI

D L

A N

G U

A G

E A

C A

D E

M Y

T

K P

LA

Y

G R

O U

N D

S E

U C

L

ID

A V

E

O N

T A

R

IO

C

A

O N

T A

R

IO

-M O

N T

C L A

IR

S

C H

O O

L D

IS

T

R

IC

T

D

ES

IG

N

D

EV

EL

O

P M

EN

T

/1

6/

DESIGN DEVELOPMENT

KEYNOTES

DESCRIPTION

:SCALE1" = 20'-0"

OVERALL SITE PLAN

SITE PLAN LEGEND

LIMIT/SCOPE OF WORK

SYNTHETIC TURF, AS PER

LANDSCAPE DRAWINGS

PIP RUBBERIZED SURFACING,

REFER TO CIVIL SITE PLAN CX AND DETAILS CX

CONCRETE PAVING,

REFER TO CIVIL SITE PLAN CX AND DETAILS CX

1. CONTRACTOR SHALL REVIEW THE CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONTRACTIBILITY. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDINGS AND SHALL DETERMINE ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL NOTIFY THE ARCHITECT

AND OWNER OF ANY DISCREPANCIES.

3. CONTRACTOR SHALL THOROUGHLY INVESTIGATE, VERIFY AND BEAR RESPONSIBILITY FOR DIMENSIONS AND EXISTING CONDITIONS. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONDITION REQUIRING MODIFICATION OR CHANGE PRIOR TO STARTING WORK. ANY WORK INSTALLED IN CONFLICT WITH THE DRAWINGS WITHOUT PRIOR APPROVAL SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S

EXPENSE.

4. WHERE EXISTING FINISHES, FACILITIES, AND SURFACES ARE DISTURBED, DAMAGED, OR REMOVED DURING

THE COURSE OF CONSTRUCTION OPERATIONS, THE CONTRACTOR IS TO REPAIR OR REPLACE AS

NECESSARY TO MATCH EXISTING. ALL NEW MATERIALS SHALL MATCH EXISTING IN ALL RESPECTS.

5. LOCATIONS OF UTILITIES, WHERE SHOWN, ARE APPROXIMATE, AND CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATING AND TRENCHING ON ALL SITES TO AVOID EXISTING DUCTS, PIPING, OR CONDUITS, ETC. AND TO PREVENT HARM TO PERSONNEL AND/OR DAMAGE TO EXISTING UTILITIES AND STRUCTURES. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER SHOULD

UNIDENTIFIED CONDITIONS BE DISCOVERED.

6. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY WHERE THE PROPOSED WORK AFFECTS THE EXISTING IRRIGATION SYSTEMS THE CONTRACTOR SHALL PERFORM ANY WORK NECESSARY TO MAINTAIN AN

OPERATIONAL IRRIGATION SYSTEM.

7. THESE DRAWINGS AND SPECIFICATIONS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION

SAFETY.

8. CONSTRUCTION WORKERS WILL ONLY BE ALLOWED IN THE AREAS APPROPRIATE TO THE WORK AND SHALL

NOT DISTURB THE OWNER, STAFF, STUDENTS OR CUSTOMERS.

9. CONSTRUCTION WORKERS SHALL WEAR APPROPRIATE SAFETY GEAR & COMPLY WITH SAFETY

REGULATIONS.

10. CONSTRUCTION WORKERS SHALL DRESS & BEHAVIOR IN A MANNER APPROPRIATE TO THE JOB SITE AND BE

ACCEPTABLE TO THE OWNER REPRESENTATIVES.

11. SMOKING IS NOT PERMITTED ON THE CONSTRUCTION SITE.

12. THERE SHALL BE NO POSSESSION OR CONSUMPTION OF DRUGS OR ALCOHOLIC BEVERAGES ON THE JOB SITE BY ANY PERSON AT ANY TIME OR CONSUMPTION PRIOR THAT MAY IMPAIR THE USE OF EQUIPMENT IN A

SAFE MANNER.

GENERAL NOTES

11.001

11.001

11.001

11.001

32.019

32.028

32.029 32.019

32.024

32.024

32.015

32.014

32.024

32.015

TYP.

32.03132.031

32.03032.030

TYP.

02.150

02.151

02.15202.152

R

1'

0"

32.05132.051

32.052

32.052

02.153

SPECTRAPOUR SUPREME

TYPE II STONE, MIN 4",

COMPACTED TO 95%

CONCRETE CURB

SECTION

0' - 6"

SBR CUSHION LAYER,

MEET ASTM F1292

REQUIREMENTS

3/8" RADIUS

EXISTING COMPACTED NATIVE SOIL

CONCRETE FOOTING

SBR "CUSHION" LAYER

SPECTRAPOUR SUPREME -

1/2" MINIMUM THICKNESS

1.5" THICKENED SURFACE AT

45° BEVEL AGAINST POST

SUB-BASE

COMPACTED SUB-GRADE

4" MIN. CLASS II ROAD

BASE, 95% COMPACTION

SBR CUSHION LAYER

0.5" - 0.75" SYNTHETIC INFILL

1.75" SYNTHETIC TURF ±.25"

1" X 4" OR 2" X 4" SYNTHETIC NAILER

BOARD TOP OF NAILER BOARD TO

BE SET AT 0.5" BELOW TOP OF CURB

DETAIL A

0' - 6"

DETAIL B

0' - 6"

COMPACTED SUB-GRADE

4" MIN. CLASS II

AGGREGATE AND DG

0.5" - 0.75" SYNTHETIC INFILL

1.75" SYNTHETIC TURF ±.25"

1" X 4" OR 2" X 4" SYNTHETIC NAILER

BOARD TOP OF NAILER BOARD TO

BE SET AT 0.5" BELOW TOP OF CURB

SBR CUSHION LAYER

ARTIFICIAL TURF GLUED

DIRECTLY TO SBR @ WEAR

COURSE SEAM

SUB-BASE

1/2" WEAR COURSE

SECTION

P R

O

JE

C T

N U

M B

E R

D A

T E

D

E

LT

A

D E

S C

R

IP

T

IO

N

P R

O

JE

C T

S T

A T

U S

S H

E E

T

IS

S U

E D

S G

H A

R C

H

IT

E C

T S

IN

C

A

LL

R

IG

H

T S

R E

S E

R V

E D

S E

A

LS

C

O N

S U

LT

A

N T

A# 04-125930

/9

/2

4:

:2

P

M C

:\U se rs \x liu \D oc um en ts

\E

LA

_O M

S D

_T K

_K _P la yg ro un d_ R

C

C _x liu Z

V V

2Q .r vt

-9

-0

S

IT

E P

LA

N

E

N

LA

R G

E D

P

LA

N S

A1.31

E U

C

LI

D L

A N

G U

A G

E A

C A

D E

M Y

T

K P

LA

Y

G R

O U

N D

S E

U C

L

ID

A V

E

O N

T A

R

IO

C

A

O N

T A

R

IO

-M O

N T

C L A

IR

S

C H

O O

L D

IS

T

R

IC

T

D

ES

IG

N

D

EV

EL

O

P M

EN

T

/1

6/

DESIGN DEVELOPMENT

NORTH

DESCRIPTION

02.150 (E) MECHANICAL CONDENSING UNIT TO REMAIN, PROTECT IN PLACE. PROVIDE NEW GALANIZED

STEEL SECURITY CAGE WITH HINGED ACCESS GATES

02.151 (E) VENT TO REMAIN, PROTECT IN PLACE

02.152 (E) GROUND PULL BOX TO BE ADJUSTED FLUSH WITH THE ADJACENT SURFACES. PROVIDE

PROTECTIVE COVER OVER EXISTING GROUND PULL BOX. PROTECT IN PLACE

02.153 (E) STORM DRAIN INLET GRATE TO REMAIN, PROECT IN PLACE

11.001 PLAYGROUND STRUCTURES, OFCI

32.014 CONCRETE CURB - FLUSH / ZERO FACE

32.015 CONCRETE CURB - RAISED

32.019 PERVIOUS / POROUS CONCRETE PAVING

32.024 CONCRETE SEATING WALL

32.028 4'x6' PICNIC TABLES, OFOI

32.029 CRITICAL FALL ZONE: POURED-IN-PLACE (PIP) RUBBERIZED SAFETY SURFACING SYSTEM (EPDM

WEAR COURSE OVER SBR CUSHION LAYER). THICKNESS AS REQUIRED TO MEET CRITICAL FALL

HEIGHT PER ASTM F1292. COLOR TO BE SELECTED BY ARCHITECT

32.030 CRITICAL FALL ZONE: SYNTHETIC TURF SURFACING WITH SYSTEM SHOCK PAD UNDERLAYMENT

CERTIFIED TO MEET CRITICAL FALL HEIGHT REQUIREMENTS PER ASTM F1292. COLOR TO BE

SELECTED BY ARCHITECT

32.031 NON-CRITICAL ZONE: SYNTHETIC TURF SURFACING OVER COMPACTED CLASS 2 AGGREGATE

BASE AND DG LEVELLING COURSE, COLOR TO BE SELECTED BY ARCHITECT

32.051 4'-0" HIGH DECORATIVE PICKET METAL FENCE SHALL BE GALVANIZED & PAINTED TO MATCH (E)

DISTRICT STANDARD COLOR: DUNN EDWARDS DE-5853 BLUE EARTH

32.052 4'-0" HIGH DECORATIVE PICKET METAL GATE WITH PANIC HARDWARE

KEYNOTES

:SCALE3/16" = 1'-0"

ENLARGED SITE PLAN

:SCALE1 1/2" = 1'-0"

PIP CURB EDGE

:SCALE3" = 1'-0"

POST DETAIL

:SCALE1 1/2" = 1'-0"

SYNTHETIC TURF EDGE

:SCALE3" = 1'-0"

SYNTHETIC TURF TO PIP

NOTES:

1. PLAYGROUND EQUIPMENT SHALL BE INSTALLED BY CERTIFIED INSTALLERS APPROVED BY THE EQUIPMENT MANUFACTURER.

2. PLAYGROUND EQUIPMENT INSTALLER SHALL VERIFY AND COORDINATE THE EQUIPMENT FOOTING LOCATIONS WITH EXISTING

UNDERGROUND UTILITY PIPES PRIOR TO INSTALLATION. INFORM THE ARCHITECT OF ANY CONFLICTS PRIOR OF EQUIPMENT INSTALLATION.

3. ADJUST THE ELEVATIONS OF EXISTING UTILITY BOX COVERS TO BE FLUSH WITH ADJACENT SURFACES.

Sheets
A1.11 - SITE PLAN - OVERALL
A1.31 - SITE PLAN - ENLARGED PLANS
G0.01 - TITLE SHEET
G1.11 - SITE PLAN - ACCESSIBILITY SITE PLAN

File details come from the government source that posted it. Updated .