5-Addendum 2 w Attach.pdf
PDF 644 KB Posted
- Attached to
- Main Pump House and Dewatering Improvements
- Solicitation number
- US.250316
- Issued by
- Lehigh County, Pennsylvania
About this file
Addendum No. 2, issued October 12, 2026, by CHA Consulting on behalf of Lehigh County Authority for Bid No. 50661 (Main Pump House and Dewatering Improvements at Kline's Island Wastewater Treatment Plant), modifies the specifications and drawings for the project. The addendum updates the roller window shades specification (Section 12 24 13) in its entirety and revises the plumbing fixture schedule on Drawing P-7.1 to specify replacement lavatory and shower enclosure components, including an American Standard Aqualyn drop-in countertop sink with Chicago metering faucet (0.35 GPM) and a Bestbath multi-piece gelcoat/fiberglass alcove shower enclosure with Zurn drain and Powers Hydropanel II combination valve. Additionally, Sketch CSKP-01 is revised to include a newly issued water heater concrete pad detail for the dewatering building partial basement plan. The bid due date for this project remains Friday, October 16, 2026, at 11:00 a.m. via PennBid.
The addendum includes comprehensive specifications for manually operated bead chain-and-clutch roller shades with inside-mount configuration, fabric-wrapped fascia, and endcaps, with a basis-of-design product established as Draper, Inc. FlexShade cassette roller shade. The specifications require manufacturer certifications for compliance with ANSI/WCMA A100.1 and 16 CFR Part 1260 safety standards, NFPA 701 fire performance testing, and GREENGUARD Gold indoor air quality certification. Substitute products must match salient characteristics of the basis-of-design product. The specification establishes fabrication tolerances, performance requirements including roller deflection limits and light control parameters, and requires manufacturer-authorized installers with minimum three years of documented experience. No pricing information, set-asides, or funding sources are specified in this addendum document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum No. 2 Page 1 of 2 10/12/26
Addendum No. 2 Issued: October 12, 2026
Project Name: Lehigh County Authority
Kline’s Island Wastewater Treatment Plant
Main Pump House and Dewatering Improvements
Bid # 50661
Project Owner: Lehigh County Authority
Construction: CHA Consulting, One East Broad St., Suite 310
Bethlehem, PA 18018
BID DUE DATE: Friday, October 16, 2026 @ 11:00 a.m. via PennBid
1.0 GENERAL INFORMATION:
1.1 This addendum consists of 7 pages including the following attachments:
• 4 pages of 12 24 13 Roller Window Shades.
• 1 page of Sketch CSKP-01.
2.0 CHANGES TO PREVIOUS ADDENDA:
2.1 None.
3.0 CHANGES TO THE BIDDING REQUIREMENTS, CONTRACT FORMS, &
CONDITIONS OF THE CONTRACT:
3.1 None.
4.0 CHANGES TO THE SPECIFICATIONS:
4.1 DELETE 12 24 13 Roller Window Shades in its entirety and REPLACE with the attached
12 24 13 Roller Window Shades, Addendum No. 2 dated 10/12/26.
5.0 CHANGES TO THE DRAWINGS:
5.1 Sketch CSKP-01‘Dewatering Building Partial Basement Plan – Drainage’ ADD newly issued
Sketch included as an attachment to this Addendum for the water heater concrete pad detail.
5.2 Drawing number P-7.1, plumbing fixture schedule – REPLACE:
a.) LAV-1 with as follows ‘LAV-1; AMERICAN STANDARD / 0476.028 AQUALYN
DROP-IN COUNTERTOP SINK; CHICAGO 3501-4E39VPABCP METEREING
The following clarifications, amendments, additions, deletions, revisions and/or modifications shall become part of the Contract and DELETE or modify the original bidding documents to the extent indicated or stated herein.
Addendum No. 2 Page 2 of 2 10/12/26
FAUCET, 0.35 GPM LAMINAR OUTLET, 4"CENTERS; VITREOUS CHINA
LAVATORY, COUNTERTOP DROP-IN, HOLES ON 4" CENTERS, (0.35 GPM
OUTLET). REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT.
b.) SH-1 with as follows ‘BESTBATH / 4LBS3636.V2 MULTI-PIECE
GELCOAT/FIBERGLASS ALCOVE SHOWER ENCLOSURE WITH CENTER
DRAIN, MOLDED LEDGES AND CENTER DRAIN; ZURN FD2260-PV2 SHOWER
DRAIN, POWERS HYDROPANEL II #450-7103 WITH HYDROGUARD T/P SERIES
E700 COMBINATION VALVE WITH SWIVEL SHOWERHEAD LESS SOAP DISH;
COMMERCIAL SHOWER ENCLOSURE WITH SURFACE MOUNTED
TEMPERATURE AND PRESSURE BALANCING SHOWER SYSTEM WITH HIGH
TEMPERATURE LIMIT STOP. ASSE 1016.
END OF ADDENDUM NO. 2
LEHIGH COUNTY AUTHORITY – KLINE’S ISLAND WWTP ISSUE FOR BID
LCA BID NO. 50661
MAIN PUMP HOUSE AND DEWATERING IMPROVEMENTS
ROLLER WINDOW SHADES 12 24 13 - 1
SECTION 12 24 13
ROLLER WINDOW SHADES
PART 1 – GENERAL
1.1 SUMMARY
A. Section Includes:
1. Manually operated bead chain-and-clutch roller shades, inside mounted to window jambs, with surface-mounted cassette headbox, fabric-wrapped fascia, and endcaps.
B. Related Requirements:
1. Section 06 10 00 "Rough Carpentry" for blocking at window heads and jambs.
2. Section 08 50 00 "Windows" for window frame and hardware dimensions.
3. Section 09 91 23 "Interior Painting" for field painting of headbox, if primer-finish is selected.
1.2 REFERENCES
A. ANSI/WCMA A100.1, "American National Standard for Safety of Corded Window Covering
Products" [verify current edition].
B. 16 CFR Part 1260, "Safety Standard for Operating Cords on Custom Window Coverings."
C. NFPA 701, "Standard Methods of Fire Tests for Flame Propagation of Textiles and Films."
1.3 DEFINITIONS
A. Chain Tensioner: Device that anchors the bead chain loop to the jamb or wall and maintains tension on the loop, as required by referenced safety standards.
B. Inside Mount: Shade installed within the window opening, with headbox and shadeband fitting between jambs.
1.4 ACTION SUBMITTALS
A. Product Data: Manufacturer's data sheets, performance data, and installation instructions.
B. Shop Drawings: Show window-by-window layout, shade sizes, headbox and jamb bracket locations, chain side, chain length, tensioner location, and clearances to glazing, window hardware, and adjacent shades.
C. Samples for Selection: Fabric, fascia fabric, and hardware finish samples showing full range available.
D. Samples for Verification: Minimum 4 in by 4 in fabric swatch of each selected color and openness; hardware finish samples of headbox, endcaps, hem bar, and bead chain.
1.5 INFORMATIONAL SUBMITTALS
A. Product Certificates: Manufacturer certification of compliance with referenced safety standards, including tensioner requirements.
B. Product Test Reports: NFPA 701 reports for each fabric, including the test method applied.
C. Environmental Certificates: GREENGUARD Gold certificates for each selected fabric.
ROLLER WINDOW SHADES 12 24 13 - 2
D. Field Measurement Report: Recorded opening dimensions and depths.
1.6 CLOSEOUT SUBMITTALS
A. Operation and Maintenance Data: Cleaning and inspection instructions, chain and clutch care, and child-safety notices.
1.7 QUALITY ASSURANCE
A. Installer Qualifications: Manufacturer-authorized installer with minimum [3] years' documented experience on projects of similar scope.
B. Preinstallation Meeting: Conduct at project site before installation to review mounting conditions, blocking, field measurements, and coordination.
1.8 DELIVERY, STORAGE, AND HANDLING
A. Deliver shades labeled by location. Store in original packaging, off floor, in a clean, dry, conditioned space.
1.9 FIELD CONDITIONS
A. Field Measurements: Verify opening width (top, middle, bottom), height, and jamb depth at each window before fabrication. Report out-of-square or inadequate-depth openings to
Architect.
1.10 WARRANTY
A. Manufacturer's Warranty: [Manufacturer's standard] warranty against defects in materials and workmanship for [5] years from Substantial Completion.
1.11 EXTRA MATERIALS
A. Furnish [1] spare bead chain and [12 in by full-width] fabric remnant per color, packaged and labeled.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Basis-of-Design Product: Draper, Inc., FlexShade cassette roller shade, [inside-mount configuration; verify exact product name].
1. Manufacturer Contact: Draper, Inc., 411 S. Pearl St., Spiceland, IN 47385;
765.987.7999; www.draperinc.com.
B. Substitutions: Comply with Section 01 25 00 "Substitution Procedures." Substitute products must match the salient characteristics of the basis-of-design product: full aluminum surface cassette with fabric-wrapped fascia and endcaps; inside jamb mounting; bead chain-and-clutch operation with tensioner; and specified fabric properties.
2.2 PERFORMANCE REQUIREMENTS
A. Safety: Comply with ANSI/WCMA A100.1 and 16 CFR Part 1260.
ROLLER WINDOW SHADES 12 24 13 - 3
B. Fire Performance: Shadeband and fascia fabric to pass NFPA 701, [Test Method 1] [Test
Method 2] as applicable to fabric weight.
C. Indoor Air Quality: GREENGUARD Gold certified fabrics.
D. Roller Deflection: Not to exceed [1/8 in] at full width under shadeband load.
E. Fabrication Tolerances: Width [+/- 1/8 in]; length [+/- 1/4 in]; squareness [1/8 in] measured corner to corner.
F. Light Control: Light gap at each jamb not to exceed [1/2 in] [verify against manufacturer clearances]. True blackout performance is not provided by this system.
2.3 MANUALLY OPERATED ROLLER SHADES
A. Operating Mechanism: Continuous-loop bead chain and bi-directional commercial clutch holding shade at any position without drift.
1. Bead Chain: [Stainless steel] [Nickel-plated steel] [Polyester plastic].
2. Chain Control Side: [Left] [Right] as indicated on drawings.
3. Chain Length: Sized for operation from floor, terminating [__ in] above finished floor
[or per drawings].
4. Chain Tensioner: Manufacturer's tensioner, fastened to the jamb or wall with fasteners suited to the substrate.
B. Roller Tube: 1.5 in (38 mm) extruded aluminum, permanently lubricated end assemblies.
C. Surface Headbox (Cassette): Extruded aluminum enclosing top, front, and back of roller.
1. Profile: Square, approx. 3-7/8 in by 3-7/8 in
2. Mounting: Surface mounted to head jamb using manufacturer's brackets, within the window opening. Provide minimum jamb depth per manufacturer's data including clearance to glazing and operable hardware.
D. Fascia: Fabric-wrapped fascia on open-bottom headbox, in fabric [matching] [coordinating with] shadeband, as selected by Architect.
E. Endcaps: Color-matched aluminum or manufacturer's standard endcaps closing headbox ends.
F. Bottom (Hem) Bar: [Enclosed in sealed fabric pocket] [Exposed rectangular with endcaps]
[Exposed round with endcaps].
G. Hardware Finish: Powder coat on headbox, endcaps, and exposed hem bar: [Black] [White]
[Taupe] [Warm White] [Grey] [Textured Bronze].
H. Roll Direction: [Regular] [Reverse] roll, fabric facing room.
2.4 SHADEBAND MATERIALS
A. Fabric Composition: [Fiberglass core, vinyl coated] [Polyester core, vinyl coated] [PVC-free polyester].
B. Openness Factor: [5%] per Fabric Schedule.
C. Series and Color: As selected by Architect from manufacturer's standard collection.
D. Fabric Properties: Colorfast and dimensionally stable; lie flat without curl or bowing when installed.
ROLLER WINDOW SHADES 12 24 13 - 4
2.5 FABRICATION
A. Unit Sizes: Fabricate to measured opening less manufacturer's required jamb clearance.
Maximum size: [96 in wide by 96 in drop] [verify]. Where openings exceed maximum, provide [adjacent shades separated by mullions] [coupled units per manufacturer].
B. Shadeband: Fabricated without seams or battens where possible. Attach fabric to roller and hem bar so attachment is secure, with no visible telegraphing or edge curl.
C. Fabric Width: Deduct manufacturer's required amount from headbox width for cloth width
[verify; source lists 1.57 in].
D. Labeling: Permanently label each unit with location, size, and manufacturer's safety warnings.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify openings are plumb, square, and within tolerances for fabricated sizes; jamb depth is sufficient for headbox and shadeband; and head and jamb substrates provide adequate support
(blocking) for brackets and tensioners.
B. Report unsatisfactory conditions in writing. Do not proceed until corrected.
3.2 COORDINATION
A. Verify clearance to window operating hardware, glazing stops, mullions, adjacent shades, sprinklers, diffusers, and lighting.
3.3 INSTALLATION
A. Install per manufacturer's instructions, level, plumb, and true.
B. Secure headbox to head jamb with brackets and fasteners suited to jamb material.
C. Anchor chain tensioner to jamb or wall as required by referenced standards, keeping chain loop under constant tension.
D. Verify endcaps and fascia are seated tightly and evenly.
E. Adjust so shades operate smoothly, hang level, and track true without binding.
3.4 CLEANING AND PROTECTION
A. Clean shades and headboxes per manufacturer's instructions.
B. Protect installed shades from damage until Substantial Completion.
3.5 DEMONSTRATION
A. Train Owner's personnel in operation, child-safety features, and maintenance.
END OF SECTION 12 24 13