This is a Limited Asbestos Inspection and Lead-Based Paint Survey report prepared by Hill West Environmental for the State of Utah, Department of Administrative Services, Division of Facilities Construction and Management (DFCM), addressing the Russell C Taylor Building located at 1526 East Medical Center Drive in St. George, Utah. The inspection was conducted on May 14, 2026, in advance of a roof replacement project and was limited to areas that will be impacted during the renovation work. The survey assessed suspect materials including roof core and caulking to identify asbestos-containing materials (ACM) and building components with lead-based paint requiring remediation prior to renovation activities.
The inspection findings indicate that no asbestos-containing materials were detected in any of the suspect building materials tested within the project area, no lead materials will be impacted during the renovation project, and no Universal, Hazardous, and Toxic Wastes will be affected by the project. The report establishes that the renovation contractor shall immediately stop work and notify DFCM if any additional suspect building materials not sampled during this inspection are discovered. The associated bid opportunity for this roof replacement project, identified as Project #27311640, includes full roof membrane replacement with added insulation, carries a construction cost estimate of $600,000.00, and is restricted to contractors prequalified under the DFCM Stage I Prequalification process and currently listed on the respective DFCM Prequalified Contractors list as of the solicitation date.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED ASBESTOS INSPECTION
AND LEAD-BASED PAINT SURVEY
Russell C Taylor Building
1526 East Medical Center Drive
St. George, Utah 84790
Roof Replacement
May 30, 2026
Prepared for:
Ms. Aubrey Stapel
Project Manager, Statewide Programs
State of Utah
Department of Administrative Services
Division of Facilities Construction and Management (DFCM)
Taylorsville State Office Building
4315 South 2700 West, 3rd Floor
Taylorsville, Utah 84129-2128
Prepared by:
Hill West Environmental
7963 Douglas Drive
Park City, Utah 84098
State of Utah Company Certification # ASBC-495
Claude Dahlk, CHMM, CIEC
(801) 450-8060
EXECUTIVE SUMMARY
On May 14, 2026, Hill West Environmental conducted a limited pre-renovation inspection for asbestos and lead-based paint at Russell C Taylor Building located at 1526 East Medical Center Drive, St. George, Utah 84790. The project includes roof replacement of the Russell C Taylor Building.
Ms. Aubrey Stapel, Project Manager with the State of Utah, Division of Facilities Construction and Management (DFCM) requested this inspection to identify asbestos-containing materials (ACM) and building components with lead-based paint that need to be addressed before the building is renovated.
Suspect materials that will be impacted included roof core and caulking. Areas in which renovations are to occur were inspected, and all other areas were not inspected as part of this survey. Hill West identified the following asbestos-containing materials (ACM) and lead-based paint during this inspection:
Asbestos-Containing Materials
Homogeneous Area Number
Material Description
Asbestos Content
Amount
Cost Estimate
N/A No asbestos materials were identified in the samples collected during this inspection.
N/A N/A N/A
Building Components with XRF Lead readings ≥ 0.4 mg/cm2
Material Type Reading (mg/cm2)
No Lead materials will be impacted during this project and therefore no samples were collected
N/A
Universal, Hazardous, and Toxic Wastes
Material Type Quantity
No Universal, Hazardous, and Toxic Wastes will be impacted during this renovation project. N/A
Conclusions
ACM – Asbestos Containing Materials (ACM) were not detected within any of the suspect building materials that were tested within the project area.
If the renovation or demolition contractor discovers additional suspect building materials that were not sampled as part of this inspection, they shall stop working and notify DFCM so that the materials can be sampled.
Lead – Lead materials will not be impacted during this renovation project and therefore, no samples were collected. If the contractor discovers other materials that will be impacted during this project that were not sampled, they shall stop work and alert DFCM that suspected materials require additional testing to determine if they are regulated.
Universal, Hazardous and Toxic Wastes – No Universal, Hazardous, and Toxic Wastes will be impacted during this renovation project.
1.0 INTRODUCTION
As per DFCM’s instructions, Hill West Environmental conducted a limited asbestos inspection of the Russell C Taylor Building located at 1526 East Medical Center Drive, St. George, Utah 84790. Due to the remodel and upgrade projects, Hill West was instructed to only inspect areas that will be impacted during the renovation project.
The purpose of this survey was to identify the existence, extent, and condition of both friable and non-friable asbestos-containing materials (ACM) and lead-based paint within the renovation areas.
2.0 SITE VISIT /OBSERVATIONS
2.1 Asbestos Inspection
On May 14, 2026, Hill West Environmental visited the site to survey the renovation areas of the building. A complete asbestos inspection of the areas that will be impacted during renovations was made to determine conditions and develop a sampling scheme for the areas. Table 1 summarizes the asbestos inspection results.
Table 1 – Asbestos Materials
Homogenous Area Number
Material Description/Location Asbestos Content
Amount Cost Estimate
N/A No asbestos materials were identified in the inspection.
N/A N/A N/A
Appendix A contains photographs of samples.
Appendix B contains analytical results and certifications.
3.0 RESULTS
Table 3 summarizes the analytical results for the asbestos samples collected.
Table 3 – Asbestos Analytical Results
Sample Number
Homogeneous Area Number
Material Sampled Sample Location Estimated Quantity*
Analytical Results
TH – 01A M001 Roof Core Roof <30,000 ft2 None Detected
TH – 01B M001 Roof Core Roof <30,000 ft2 None Detected
TH – 01C M001 Roof Core Roof <30,000 ft2 None Detected
TH – 01D M001 Roof Core Roof <30,000 ft2 None Detected
TH – 01E M001 Roof Core Roof <30,000 ft2 None Detected
TH – 01F M001 Roof Core Roof <30,000 ft2 None Detected
TH – 01G M001 Roof Core Roof <30,000 ft2 None Detected
TH – 02A M002 White Caulk Roof <100 ft2 None Detected
TH – 02B M002 White Caulk Roof <100 ft2 None Detected
TH – 02C M002 White Caulk Roof <100 ft2 None Detected
TH – 03A M003 Black Caulk Roof <100 ft2 None Detected
TH – 03B M003 Black Caulk Roof <100 ft2 None Detected
TH – 03C M003 Black Caulk Roof <100 ft2 None Detected
* Estimated Quantity is based on amount to be disturbed during the upgrade project.
4.0 DISCUSSION/CONCLUSTIONS
In Utah, EPA asbestos regulations are administered by the Utah Division of Air Quality. Utah Occupational Safety and Health Administration (UOSHA) has adopted the Federal OSHA regulations. In addition, the Salt Lake Valley Health Department (SLVHD) regulates demolition activities in Salt Lake County. The SLVHD regulations for pre-demolition building inspections require an asbestos inspection, but also require building owners to inspect the building for other hazardous materials such as universal wastes, hazardous and toxic wastes and lead-based paint. Similar to asbestos, these wastes, if present must be removed prior to demolition/renovation.
A copy of this report should be on-site during all renovation activities.
This limited asbestos and lead-based paint inspection was conducted at the Russell C Taylor Building that will be impacted during renovation activities. Only items that are believed to be impacted during renovation activities were inspected during this survey. This survey is not intended to represent an exhaustive research into all asbestos or other hazards or conditions which may exist within other buildings located at this project site.
This report does not purport to represent future indoor conditions or events.
Situations or activities which transpire subsequent to this report, which result in adverse environmental, construction and/or engineering impacts, are not to be construed as relevant to this study.
This report is intended for the sole use of Hill West's client. This report may not be used or relied upon by any other party without the written consent of Hill West.
The scope of services performed in execution of the evaluation may not be appropriate to satisfy the needs of other users, and the use or re-use of this document or the findings, conclusions, or recommendations is at risk of said user. Appendix B contains all Company certifications and individual inspector certifications.
Prepared by:
Claude Dahlk, CHMM, CIEC Asbestos Inspector ASB-0433
Appendix A
Photographs of Samples
Utah Tech Univeristy - Russel C Taylor Building
1526 East Medical Center Drive
St.George, Utah
TH – 01A Roof Core
TH – 01B Roof Core
TH – 01C Roof Core
TH – 01D Roof Core
TH – 01E Roof Core
TH – 01F Roof Core
TH – 01G Roof Core
TH – 02A White Caulk
TH – 02B White Caulk
TH – 02C White Caulk
TH – 03A Black Caulk
TH – 03B Black Caulk
TH – 03C Black Caulk
End of Photographs.
Appendix B
Analytical Results and Certifications
Approved by:
Approved Signatory Renee Luna-Trepczynski
Report for:
Claude Dahlk Hill West Environmental, LLC 7963 Douglas Drive Park City, UT 84098
Regarding:
Eurofins Aerotech Built Environment Testing, LLC Project: Russell C. Taylor Building; 1526 East Medical Center Dr
EML ID: 4546413
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Aerotech Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 05-21-2026
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 500031-0
EMLab ID: 4546413, Page 1 of 6Eurofins Aerotech Built Environment Testing, LLC
Eurofins Aerotech Built Environment Testing, LLC 1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Russell C. Taylor Building; 1526 East Medical Center Dr
Date of Sampling: 05-14-2026 Date of Receipt: 05-21-2026 Date of Report: 05-22-2026
ASBESTOS PLM REPORT
Total Samples Submitted: 13 Total Samples Analyzed: 13
Total Samples with Layer Asbestos Content > 1%: 0
Location: TH-01A, Roof Core Lab ID-Version‡: 22896318-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
Location: TH-01B, Roof Core Lab ID-Version‡: 22896319-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
Location: TH-01C, Roof Core Lab ID-Version‡: 22896320-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 4546413, Page 2 of 6Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Russell C. Taylor Building; 1526 East Medical Center Dr
Date of Sampling: 05-14-2026 Date of Receipt: 05-21-2026 Date of Report: 05-22-2026
ASBESTOS PLM REPORT
Location: TH-01D, Roof Core Lab ID-Version‡: 22896321-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
Location: TH-01E, Roof Core Lab ID-Version‡: 22896322-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
Location: TH-01F, Roof Core Lab ID-Version‡: 22896323-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 4546413, Page 3 of 6Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Russell C. Taylor Building; 1526 East Medical Center Dr
Date of Sampling: 05-14-2026 Date of Receipt: 05-21-2026 Date of Report: 05-22-2026
ASBESTOS PLM REPORT
Location: TH-01G, Roof Core Lab ID-Version‡: 22896324-1
Sample Layers Asbestos Content Black/White Roofing Material (Membrane) ND
Yellow Foam Board with Gray Felt ND Yellow Foam Board with Gray Felt (Partial) ND
Composite Non-Asbestos Content: 3% Cellulose < 1% Glass Fibers < 1% Synthetic Fibers
Sample Composite Homogeneity: Poor
Location: TH-02A, White Caulk Lab ID-Version‡: 22896325-1
Sample Layers Asbestos Content White Caulk ND
Sample Composite Homogeneity: Good
Location: TH-02B, White Caulk Lab ID-Version‡: 22896326-1
Sample Layers Asbestos Content White Caulk ND
Sample Composite Homogeneity: Good
Location: TH-02C, White Caulk Lab ID-Version‡: 22896327-1
Sample Layers Asbestos Content White Caulk ND
Sample Composite Homogeneity: Good
EMLab ID: 4546413, Page 4 of 6Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Russell C. Taylor Building; 1526 East Medical Center Dr
Date of Sampling: 05-14-2026 Date of Receipt: 05-21-2026 Date of Report: 05-22-2026
ASBESTOS PLM REPORT
Location: TH-03A, Black Caulk Lab ID-Version‡: 22896328-1
Sample Layers Asbestos Content Gray Caulk with Brown Surface ND
Sample Composite Homogeneity: Good
Location: TH-03B, Black Caulk Lab ID-Version‡: 22896329-1
Sample Layers Asbestos Content Gray Caulk with Brown Surface ND
Sample Composite Homogeneity: Good
Location: TH-03C, Black Caulk Lab ID-Version‡: 22896330-1
Sample Layers Asbestos Content Gray Caulk with Brown Surface ND
Sample Composite Homogeneity: Good
EMLab ID: 4546413, Page 5 of 6Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Russell C. Taylor Building; 1526 East Medical Center Dr
Date of Sampling: 05-14-2026 Date of Receipt: 05-21-2026 Date of Report: 05-22-2026
ASBESTOS PLM REPORT
PROJECT ANALYST AND SIGNATORY REPORT
Project Analyst
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
Analyst: Michael Williams
EMLab ID: 4546413, Page 6 of 6Eurofins Aerotech Built Environment Testing, LLC
| Russell C Taylor Roof Replacement Limited Haz Mat Report 05 29 2026 |
| ACM Photo Log Russell C Taylor Building 05 30 26 |
| Russell C Taylor Roof Replacement Limited Haz Mat Report 05 29 2026 |
| Project-4546413_Russell C. Taylor Building (002) |
| 2026 Dahlk Hobbs HW ACM Lead Certs |
| scan_20260108062842 |
| 2025 Dahlk Hobbs HW ACM Lead Certs |
| 2024 Dahlk HW Hobbs Asbestos Certs |
| 2025 Dahlk Hobbs HW ACM Lead Certs |
| Hill West Lead Cert 2026 |
File details come from the government source that posted it. Updated .