This document consists of approved plans for a construction project managed by the Division of Facilities Construction and Management (DFCM) for the Utah State Hospital, a facility under the Department of Health & Human Services. The project involves the replacement of existing unit heaters at the Warehouse facility, identified as Project #27135420. This Stage II Invitation to Bid is restricted to contractors who have been prequalified under DFCM's Stage I Prequalification process and currently appear on the respective prequalified contractors list as of the solicitation date. The approved plans document provides the technical specifications and design requirements necessary for contractors to prepare accurate bids for the heating equipment replacement work.

The construction cost estimate for this project is $25,000.00. As a prequalified Stage II bidding opportunity, only eligible contractors meeting DFCM's prequalification criteria are permitted to submit bids. The approved plans serve as the binding technical documentation that contractors must use to scope, estimate, and execute the warehouse unit heater replacement project in compliance with state standards and requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROVO, UTAH

C001

COVER SHEET

DFCM Project No. 27135420

CONSTRUCTION DOCUMENTS

Vicinity Map

SHEET INDEX

USH - WAREHOUSE UNIT

PROJECT SITE

PROVO, UTAH

NORTH

CONSULTANTS

North: ______ South: ______ East: ______ West: ______

Special Use and Occupancy (e.g. High Rise, Covered Mall): __________________

d) Unlimited Area Building: Yes ______ No ______ Code Section: ______ a a

3) Three Story: A (3)______

2) Two Story: A (2)________

1) One Story: ______

c) Total Allowable Area for:

N/A (NON-SEPARATED OCCUPANCIES)

b) Sum of the Ratio Calculations for Mixed Occupancies:

a) 0.25I = 100f F P 30

WstA I 100100 fIA t taA = A + +

Official for Complex Buildings. Including, but not limited to:

g) Fire Stopping, Including Tested Design Number.

f) Exterior and Interior Accessibility Route.

e) Fire Assembly Locator Sheet.

a) High Rise Requirements.

b) Atriums.

c) Performance Based Criteria.

d) Means or Egress Analysis.

2) Additional Code Information shall be provided at the discretion of the Building

Code Accessibility Chapters, the more restrictive requirement shall govern.

through - ADA Guidelines and specific reference to the International Building

1) In case of conflict with the U.S. Department of Justice Federal Registers Parts

FOOTNOTES:

d) Drinking Fountains: ______ Service Sinks: ______

c) Bath Tubs or Showers: ______

b) Lavatories - Required (m) ______ (f) ______ Provided (m) ______ (f) ______

a) Water Closets - Required (m) ______ (f) ______ Provided (m) ______ (f) _____

M. Minimum Number of Required Plumbing Facilities:

Exit Width Required: ______ Exit Width Provided: ______

Element Hours Assembly ListingListing

Element AssemblyHours

Smoke Partitions Fire Partitions

Exterior Bearing Walls Interior Bearing Walls Exterior Non-Bearing Walls Structural Frame Partitions - Permanent Fire Barriers

Floors - Ceiling Floors Roofs - Ceiling Roofs Exterior Doors and Windows Shaft Enclosures Fire Walls

BAHTBABABA

Design Wind Speed: ______ mphB. Seismic Design Category: ______

L. Design Occupant Load: ______

K. Fire Resistance Rating Requirements for Building Elements (hours).

Area Modifications:J:

_____________________________________________________Tabular Area:I:

per Floor (square feet): _________________________________________Actual AreaH:

Number of Stories: ______ Building Height: ___________G:

Required: ______ Provided: _________ Type of Sprinkler System: __________

Sprinklers:F:

Mixed Occupancies: ______ Nonseparated Uses: ______E.

separation distance (in hours):

Requirements for the Exterior Walls based on the fireFire Resistance RatingD.

C. Type of Construction (circle one):

Change in Use: Yes ______ No ______ Mixed Occupancy: Yes ______ No ______

Guildelines ADA Accessibility Building Conservation Uniform Code for National Electrical Code

Conservation Code International Energy International Fire Code International Plumbing Code International Mechanical Code International Building Code

YearYear

APPLICABLE CODES

A. Occupancy and Group: _______ ________ ________ ________ ________

CODE ANALYSIS

N

N N

S-1

X X

NO

90D

NR NR NR NR

NO

YES YES NFPA 13

1 24' - 0"

11,925

N/A

3) Deferred Submittals:

a) Seismic Bracing for Mechanical and Electrical. Work related to the deferred

N/A

N/AX

17,500 submittals shall not commence until the building official has approved the submittal.

17,500 N/A N/A

20241300 East Center Street Provo, Utah 84603

HEATERS REPLACEMENT

07/16/2026

260447

JB

REVISIONS

SHEET CONTENTS

RESOLUT PROJECT #:

CHECKED BY:

DRAWN BY:

CURRENT/ISSUE DATE:A

B

C

D

E

1 2 3 4 5 6

U

SH

W

A R

EH

O

U

SE

U N

IT

H

EA

TE

R S

R

EP

LA

C

EM

EN

T

E as t C en te r S tre et P ro vo

, U ta h

181 East 5600 South Murray, UT 84107

801.530.3148 T

801.530.3150 F

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

Project #: 260447

DFCM APPROVAL STAMP

No. 8325442-2202

JACOB D.

BECK

07-16-26

JD

NO

72"

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

Jason Van Ausdal

09/03/2026

REVIEWED FOR CODE

COMPLIANCE

LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS

MECHANICAL PLUMBING PLUMBING CONT. LINETYPES LINETYPES CONT.

SYMBOLS

FIRE

M001

JD

MECHANICAL

SYMBOLS AND

ABBREVIATIONS

07/16/2026

260447

JB

REVISIONS

SHEET CONTENTS

RESOLUT PROJECT #:

CHECKED BY:

DRAWN BY:

CURRENT/ISSUE DATE:A

B

C

D

E

1 2 3 4 5 6

U

SH

W

A R

EH

O

U

SE

U N

IT

H

EA

TE

R S

R

EP

LA

C

EM

EN

T

E as t C en te r S tre et P ro vo

, U ta h

181 East 5600 South Murray, UT 84107

801.530.3148 T

801.530.3150 F

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

Project #: 260447

DFCM APPROVAL STAMP

No. 8325442-2202

JACOB D.

BECK

07-16-26

JD

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

Jason Van Ausdal

09/03/2026

T

T

T

(E) G"

(E) G"

(E) G"

UH

UH

UH

T

T

T

M501

TYP.

(E) G"

(E) G"

(E) G"

3/4"

3/4"

3/4"

M101

LEVEL 1

MECHANICAL PLANS

07/16/2026

260447

JB

REVISIONS

SHEET CONTENTS

RESOLUT PROJECT #:

CHECKED BY:

DRAWN BY:

CURRENT/ISSUE DATE:A

B

C

D

E

1 2 3 4 5 6

U

SH

W

A R

EH

O

U

SE

U N

IT

H

EA

TE

R S

R

EP

LA

C

EM

EN

T

E as t C en te r S tre et P ro vo

, U ta h

181 East 5600 South Murray, UT 84107

801.530.3148 T

801.530.3150 F

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

Project #: 260447

DFCM APPROVAL STAMP

No. 8325442-2202

JACOB D.

BECK

07-16-26

JD

KEYED NOTES#

1. DEMOLISH AND REMOVE EXISTING UNIT HEATER, THERMOSTAT

AND ASSOCIATED FLUES.

2. CONNECT TO EXISTING GAS PIPING. FIELD VERIFY EXISTING

CONDITIONS.

3. PROVIDE AND INSTALL THERMOSTAT. TYPICAL.

4. PROVIDE AND INSTALL NEW FLUE THROUGH ROOF. INSTALL

PER MANUFACTURERS RECOMMENDATIONS. FLASH AND SEAL

ROOF PENETRATION TO MATCH EXISTING. FIELD VERIFY.

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

Jason Van Ausdal

09/03/2026

M501

JD

MECHANICAL

DETAILS &

SCHEDULES

07/16/2026

260447

JB

REVISIONS

SHEET CONTENTS

RESOLUT PROJECT #:

CHECKED BY:

DRAWN BY:

CURRENT/ISSUE DATE:A

B

C

D

E

1 2 3 4 5 6

U

SH

W

A R

EH

O

U

SE

U N

IT

H

EA

TE

R S

R

EP

LA

C

EM

EN

T

E as t C en te r S tre et P ro vo

, U ta h

181 East 5600 South Murray, UT 84107

801.530.3148 T

801.530.3150 F

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

Project #: 260447

DFCM APPROVAL STAMP

No. 8325442-2202

JACOB D.

BECK

07-16-26

JD

FUEL FIRED UNIT HEATER SCHEDULE

ELECTRICAL

INPUT OUTPUT

MANUFACTURER FLUE AIRFLOW HEATING HEATING MOTOR MOTOR

AND SIZE RATE LOAD LOAD SIZE SPEED TOTAL

ID MODEL NUMBER LOCATION TYPE (IN) (CFM) (MBH) (BTU/H) (HP) (RPM) AMPS VOLT/PH/HZ NOTES

UH-1 MODINE PDP-200 SEE PLANS NATURAL GAS 7 2870 200 140 1/6 1750 5.1 115/1/60 1, 2

1. GAS HEATING INPUT AT SEA LEVEL, ALL OTHER CAPACITIES AT ELEVATION.

2. SEALED COMBUSTION.

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

Jason Van Ausdal

09/03/2026

EV EV

DO

TV

J

FB PT

J

X##

TC

CR

D

F

M

VFD

XX

POWER SYMBOLS LEGEND

SYMBOL DEVICE/FIXTURE DESCRIPTION MOUNTING NOTES

S

WALL MOUNTED RECEPTACLE

SWITCHED RECEPTACLE

EMERGENCY RECEPTACLE

GROUND FAULT RECEPTACLE

RECEPTACLE MODIFIERS:

##": HEIGHT AFF O.C.

WP: WEATHERPROOF W/ IN-USE COVER

T: TAMPER-PROOF

U: RECEPTACLE WITH USB OUTLET

G: GROUND FAULT PROTECTED @ BREAKER

H: HOSPITAL GRADE

18"

18"

D Q SP

18"

18"

RECEPTACLE (SPECIFIC HEIGHT)

ISOLATED GROUND RECEPTACLE

7, 25, 30

7, 8

18"

SWITCH MODIFIERS:

K: KEYED

T: TIMER

M: MANUAL STARTER THERMAL

OVERLOAD SWITCH

EMERGENCY POWER OFF PUSH BUTTON

DOOR OPENER PUSH PLATE

ELECTRICAL POWER METER

FUSED DISCONNECT SWITCH

TOMBSTONE RECEPTACLE

CORD REEL, DEVICE VARIES

CORD DROP, DEVICE VARIES

MULTI-OUTLET ASSEMBLY

FILLED SQUARES INDICATE 120V OUTLET

OPEN SQUARES INDICATE WITH USB

SINGLE / DUAL PORT ELECTRICAL VEHICLE

CHARGER

POWER POLE

NON-FUSED DISCONNECT SWITCH

MAGNETIC STARTER

MAGNETIC STARTER WITH FUSED DISCONNECT

PUSHBUTTON

VARIABLE FREQUENCY DRIVE

TRANSFORMER:

SEE SINGLE-LINE DIAGRAM FOR DESCRIPTION &

REQUIREMENTS.

GENERAL LEGEND

SYMBOL DESCRIPTION NOTES

SOLID ARCHED LINES INDICATE UNSWITCHED

POWER CIRCUITING

DASHED ARCHED LINES INDICATE SWITCHED

POWER CIRCUITING

ONE CIRCUIT, HOME RUN TO PANEL

SYMBOL DEVICE/FIXTURE DESCRIPTION MOUNTING NOTES

4" CONCRETE

BASE

POWER DISTRIBUTION PANEL 6'-6" TO TOP

FLUSH PANELBOARD 6'-6" TO TOP

SURFACE PANELBOARD 6'-6" TO TOP

TWO CIRCUITS, HOME RUN TO PANEL -

THREE CIRCUITS, HOME RUN TO PANEL -

CONDUIT RUN CONCEALED IN FLOOR OR GROUND -

CONDUIT RUN CONCEALED IN WALL OR CEILING -

CONDUIT UP -

CONDUIT DOWN -

CONDUIT STUB LOCATION CAP CONDUIT

CONDUIT / CIRCUIT CONTINUATION -

GROUND BUS BAR

CABLE TRAY

SOLID BOTTOM

LADDER

BASKET

MOUNTING

AS NOTED

7+18"

EQUIPMENT CEILING RACK

EQUIPMENT CABINET/RACK

EQUIPMENT 2-POST CABINET/RACK

TELEPHONE DEMARCATION BOARD +18"

FLOOR 18,

SEE SPEC.

WALL / FLOOR 18,

SEE SPEC.

CEILING

EXISTING --

DEMO --

TEMPORARY --

NEW --

CONDUIT

OHP: OVERHEAD POWER SERVICE

UGP: UNDERGROUND POWER

SERVICE

UGF: UNDERGROUND FIBER

SERVICE

TEL: TELEPHONE SERVICE

POWER DISTRIBUTION EQUIPMENT SYMBOLS

CONTROLLED RECEPTACLE 7, 8+18" OR AS

NOTED

SPD PROTECTED RECEPTACLE 7+18" OR AS

NOTED

TIME CLOCK +48"

NOT IN CONTRACT --

MAGNETIC STARTER WITH BREAKER DISCONNECT

CEILING MOUNTED RECEPTACLE CEILING

TV BACKBOX FLAT PANEL

HEIGHT +12"

NOTES:

1. HATCHED FILL INDICATES SWITCHBOARD OR POWER

DISTRIBUTION PANEL.

2. SOLID FILL INDICATES BRANCH PANEL OR LOAD CENTER.

3. DASHED BOX INDICATES CODE-REQUIRED CLEARANCE

(WIDTH & DEPTH).

4. DOOR INDICATES FRONT OF RECESSED PANEL.

H P

1A

LP

1A

M D

P

SB1

POWER TAGS LEGEND

GENERAL LEGEND

SYMBOL DESCRIPTION NOTESMOUNTING

KEYNOTE

ROOM NAME & NUMBER

DIAGRAM TAG

MATCH LINE TAG

ROOM NAME & NUMBER W/ ZONE I.D.

JUNCTION BOX

x

S: SIMPLEX D: DUPLEX

Q: FOURPLEX SP: SPECIAL PURPOSE

FLOOR BOX / POKE-THRU

- SEE SCHEDULE FOR TYPE INFORMATION

EQUIPMENT SYSTEM PANELS

ACS: ACCESS CONTROL PANEL

ATS: AUTOMATIC TRANSFER SWITCH

IDS: INTRUSION DETECTION PANEL

PSP: POWER SUPPLY PANEL

RP#: LIGHTING PANEL

DAS: DISTRIBUTED ANTENNA SYSTEM

ERCCS: FIRST RESPONDERS RADIO SYSTEM

CATV: CABLE TV CONTENT EQUIPMENT

7, 8, 13

CEILING

CEILING

+46"OR AS

NOTED

7, REFER TO

SPEC

+46" 7

+46" 7

9, 10

9, 10, 11

+72" TO TOP

+60" TO TOP

18, SEE SPEC.

7, 22

Space

Space

XX

DEVICES WITH A CHEVRON INDICATE TO

COORDINATE WITH MILLWORK PRIOR TO ROUGH-IN.

ELEVATION TAG. HATCHED AREA INDICATES

WHICH WALL, NUMBER INDICATES VIEW, AND

CENTER NUMBER INDICATES WHICH SHEET.

REVISION CLOUD DELTA. SHOWN WITH CLOUD

AND INDICATES A CHANGE PER THE TITLE BLOCK.

TAG FOR MECHANICAL, KITCHEN, AND SHOP

DEVICES. REFER TO SCHEDULES FOR INFO.

9, 10, 11

9, 10, 11

+46" 7

9, 10

+46" 7

+60" TO TOP

+60" TO TOP

+60" TO TOP

+60" TO TOP

+60" TO TOP 9, 10, 11

+60" TO TOP

FLOOR

AS NOTED 20

25, 30

+46" 7

COUNTER TOP

MATCH LINE

SEE -/---

32" OR AS

INDICATED

L I C

E N

S E D

P

ROFESS IONA

L

E N

G I N

E E

R

14275529

S

T A

T E OF U

TA

H

SANG TRUONG

No.

Project #: 260447

DFCM APPROVAL STAMP

181 East 5600 South Murray, UT 84107

801.530.3148 T

801.530.3150 F

A

B

C

D

E

1 2 3 4 5 6

07/16/2026

260447

ST

REVISIONS

SHEET CONTENTS

RESOLUT PROJECT #:

CHECKED BY:

DRAWN BY:

CURRENT/ISSUE DATE:

Resolut Group, 2025

Original drawings remain the property of the Engineer and as such the Engineer retains total ownership and control. The design represented by these drawings are sold to the client for a one time use, unless otherwise agreed upon in writing by the

Engineer.

C

U S

H

W A

R E

H O

U S

E U

N

IT

H E

A T

E R

S R

E P

L A

C E

M E

N T

E a s t

C e n te r S tr e e t

P ro v o

U ta h

SE

ELECTRICAL TITLE

SHEET

E001

ELECTRICAL ABBREVIATIONS INDEX

ABBREV. DESCRIPTION

A AMPS

AC ALTERNATING CURRENT

ACLG ABOVE CEILING

ADC ANALOG-TO-DIGITAL

CONVERTER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT

AFCI ARC FAULT CIRCUIT

INTERRUPTER

AFF / A.F.F. ABOVE FINISH FLOOR

AFG ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

AIC AMPS INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AM AMPS METER

AMP AMPERE

AMPL AMPLIFIER

ANN ANNUNCIATOR

AOE AUDIO-OVER-ETHERNET

APPROX APPROXIMATELY

AQ-STAT AQUASTAT

ARCH ARCHITECT, ARCHITECTURAL

AS AMP SWITCH

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIOVISUAL

AWG AMERICAN WIRE GAUGE

BATT BATTERY

BC BARE COPPER

BD BOARD

BFC BELOW FINISHED CEILING

BFG BELOW FINISHED GRADE

BLDG BUILDING

BMS BUILDING MANAGEMENT

SYSTEM

BPM BEATS-PER-MINUTE

C, CND CONDUIT

C.O. CONDUIT ONLY

C/W COMPLETE WITH

CAB CABINET

CAT CATEGORY CABLE

CAT# CATALOG

CATB COMMUNITY ANTENNA

TELEVISION

CATV CABLE TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CF CREST FACTOR

CKT CIRCUIT

CLG CEILING

CMPR COMPRESSOR

CNTR CONTRACTOR

CO CONDUIT ONLY

CODEC CODER-DECORDER

COMB COMBINATION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONV CONVECTOR

CP CIRCULATING PUMP

CRT COMPUTER TERMINAL

CT CURRENT TRANSFORMER

CU COPPER

CV CONSTANT VOLTAGE

DAC DIGITAL-TO-ANALOG

CONVERTER

DB DECIBEL

DBFS DB REF. FULL SCALE

DBM DB REF. 0.001 WATT

DBU DB REF. 0.775 V

DBV DB REF. 1 V

DC DIRECT CURRENT

DCP DOMESTIC CIRCULATING PUMP

DED DEDICATED

DEPT DEPARTMENT

DET DETAIL

DFA DROP FROM ABOVE

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DPR DAMPER

DR DYNAMIC RANGE

DS DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

E EXISTING TO REMAIN

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

EG EMERGENCY GENERATOR

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

ELU EMERGENCY LIGHTING UNIT

EM EMERGENCY/EGRESS BATTERY

EMI ELECTRO-MAGNETIC

INTERFERENCE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EN EXISTING TO BE REPLACED

WITH NEW

ENT ELEC. NON-METAL. TUBING

EP ELECTRIC PNEUMATIC

EQUIP EQUIPMENT

ER EXISTING TO BE RELOCATED

ES SOURCE VOLTAGE

EWC ELECTRIC WATER COOLER

EX EXISTING TO BE REMOVED AND

OFFERED UP TO THE OWNER

FOR FIRST RIGHTS OF REFUSAL.

PROPERLY AND LEGALLY

DISPOSE OF MATERIAL IF

REFUSED

FA FIRE ALARM

FABP FIRE ALARM BOOSTER PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOT CANDLE

FCU FAN COIL UNIT

FIR FINITE IMPULSE RESPONSE

FILTER

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FMC FLEXIBLE METAL CONDUIT

FU FUSE

FUDS FUSE SAFETY DISCONNECT

SWITCH

GA GAUGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

ABBREV. DESCRIPTION

GEC GRND. ELEC. COND. AT SES

GEN GENERATOR

GFCI GROUND FAULT CURRENT

INTERRUPTER

GFI GROUND FAULT INTERRUPTER

GFP GROUND FAULT PROTECTOR

GND GROUND

GRC GALVANIZED RIGID CONDUIT

GYP BD GYPSUM BOARD

HOA HAND-OFF-AUTOMATIC SWITCH

HORIZ HORIZONTAL

HP HORSE POWER

HPF HIGH POWER FACTOR

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING & AIR

CONDITIONING

HZ HERTZ

I/W INTERLOCK WITH

IC INTERRUPTING CAPACITY

IFC INTERNATIONAL FIRE CODE

IG ISOLATED GROUND

IIR INFINITE IMPULSE RESPONSE

FILTER

IMC INTERMEDIATE METALLIC

CONDUIT

INCAND INCANDESCENT

IR INFRARED

IT TOTAL CURRENT

J-BOX JUNCTION BOX

KCMIL 1000 CIRCULAR MILS (MCM)

KHZ THOUSANDS OF HZ

KV KILOVOLT

KVA KILOVOLT AMPERES

KVAR KILOVARS

KW KILOWATT

KWH KILOWATT HOUR

LCS C-WEIGHTED SLOW SOUND

LEVEL

LEQ EQUIVALENT SOUND LEVEL

LFMC LIQUID-TIGHT FLEX.

METAL. COND.

LFNC LIQUID-TIGHT FLEX. NON-METAL.

COND.

LOC LOCATE OR LOCATION

LP, SPL SOUND PRESSURE LEVEL

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LU LOUDNESS UNIT METERING

LUFS LOUDNESS UNIT FULL SCALE

LV LOW VOLTAGE

M/C MOMENTARY CONTACT

MAC MEDIA ACCESS CONTROL

MAG.S MAGNETIC STARTER

MAX MAXIMUM

MB MAIN BUS

MC MECHANICAL CONTRACTOR

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCM 1000 CIRCULAR MILLS

MDC MAIN DISTRIBUTION CENTER

MDP MAIN DISTRIBUTION PANEL

MEP MECHANICAL, ELECTRICAL, AND

PLUMBING

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT

SWITCH

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MMS MANUAL MOTOR STARTER

MNF MANUFACTURER

MOA MULTI-OUTLET ASSEMBLY

MSBD MAIN SWITCHBOARD

MSP MOTOR STARTER PANELBOARD

MSS MOTOR STARTER SWITCH

MTG MOUNTING

MTR MOTOR

MTS MANUAL TRANSFER SWITCH

N NEW

N.I.C. NOT IN CONTRACT

N/A NOT APPLICABLE

N1 NEMA 1

N3R NEMA 3R

NAC NOTIFICATION APPLIANCE

CIRCUIT PANEL

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECT.

MANUFAC. ASSOC.

NFDS NON-FUSED SAFETY

DISCONNECT SWITCH

NFPA NATIONAL FIRE PROTECTION

ASSOC.

NL NIGHT LIGHT, BYPASS LOCAL

SWITCHING

NO NORMALLY OPENED

NPF NORMAL POWER FACTOR

NTS NOT TO SCALE

NVR NETWORK VIDEO RECORDER

OC ON CENTER

OH OVERHEAD

OL OVERLOADS

OS & Y OUTSIDE SCREW & YOKE

OSI OPEN SYSTEM INTEGRATION

PA PASCAL

PB PUSHBUTTON

PBB PRIMARY BONDING BUSBAR

PC PLUMBING CONTRACTOR

PCM PULSE CODE MODULATION

PDU POWER DISTRIBUTION UNIT

PE PNEUMATIC ELECTRIC

PED PEDESTAL

PF POWER FACTOR

PFR PHASE FAILURE RELAY

PIV POST INDICATING VALVE

PLEN PLENUM

PNL PANEL

POC POINT OF CONNECTION

POE POWER OVER ETHERNET

POS POINT OF SALE

PP POWER POLE

PPM PEAK PROGRAM METER

PR PAIR

PRI PRIMARY

PROJ PROJECTION

ABBREV. DESCRIPTION

PRV POWER ROOF VENTILATOR

PSI POUNDS-PER-SQUARE-INCH

PT POTENTIAL TRANSFORMER

PTP POINT TO POINT

PTZ PAN, TILT, AND ZOOM

PVC POLYVINYL CHLORIDE CONDUIT

PWR POWER

QUAN QUANTITY

R RESISTANCE

RECEP, RECPT RECEPTACLE

REQ,REQD REQUIRED

REX REQUEST TO EXIT

RF RADIO FREQUENCY

RFM ROOF MOUNTED

RL LOAD RESISTANCE

RLA RATED LOAD AMPS

RM ROOM

RMC RIGID METALLIC CONDUIT

RMP ROCKY MOUNTAIN POWER

RMS ROOT MEAN SQUARE

RNC RIGID NON-METALLIC COND.

RPM ROTATIONS-PER-MINUTE

RS SOURCE RESISTANCE

RT TOTAL RESISTANCE

RTU ROOF TOP UNIT

RX RECEIVER

S/N SOLID NEUTRAL

S/S STOP/START PUSHBUTTONS

SBB SECONDARY BONDING BUSBAR

SBG SUPPLEMENTARY BONDING

GRID

SBJ SYSTEM BONDING JUMPER

SC SURFACE CONDUIT

SCA SHORT CIRCUIT AMPERES

SDI SERIAL DIGITAL INTERFACE

SE SERVICE ENTRANCE

SEC SECONDARY

SES SMOKE EVACUATION SYSTEM

SHT SHEET

SIM SIMILAR

SLD SINGLE-LINE DIAGRAM

SNR SIGNAL-TO-NOISE RATIO

SP SPARE

SPDIF SONY PHILLIPS DIGITAL

INTERFACE

SPEC SPECIFICATIONS

SPKR LOUDSPEAKER

SPL SOUND PRESSURE LEVEL

SPP SINGLE-POINT POWER

SR SURFACE RACEWAY

SS SELECTOR SWITCH

SSW SELECTOR SWITCH

STA STATION

STD STANDARD

STP SHIELDED TWISTED PAIR

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYM SYMMETRICAL

SYS SYSTEM

TBB TELECOMMUNICATIONS

BONDING BACKBONE

TBC TELECOMMUNICATIONS

BONDING CONDUCTOR

TC TEMP. CONTROL CONTR.

TEL TELEPHONE

TERM TERMINAL

TL TWIST LOCK

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TVTC TELEVISION TERMINAL

TX TRANSMITTER

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTED POWER

SUPPLY

UT UNDERGROUND TELEPHONE

UTIL UTILITY

UTP UNSHIELDED TWISTED PAIR

UV ULTRAVIOLET

V VOLT (KV-KILOVOLT)

VA VOLT/AMPS

VA/R, VAR VOLT-AMPS/REACTIVE

VAC VOLTS ALTERNATING CURRENT

VDC VOLTS DC CURRENT

VDT VIDEO DISPLAY TERMINAL

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VI VOLUME INDICATOR

VIF VERIFY IN FIELD

VM VOLT METER

VOL VOLUME

VU VOLUME UNIT

W WATTS

W/ WITH

W/O WITHOUT

WG WIRE GUARD

WH WATTHOUR METER

WP WEATHERPROOF/NEMA 3R

XFMR TRANSFORMER

XFMR SW SW TRANSFER SWITCH

XFR TRANSFER

XL X-CONNECTOR LOCKING

XLR X-CONNECTOR LOCKING

RUBBERIZED

XP EXPLOSION PROOF

XR EXISTING TO BE REMOVED

1P ONE-POLE

2P TWO-POLE

3P THREE-POLE

4P FOUR-POLE

∠ ANGLE

& AND

@ AT

° DEGREE

▲ DELTA

', FT FOOT, FEET

", IN INCH, INCHES

# NUMBER

Ω, OHM UNIT OF ELECTRICAL

RESISTANCE

Ø, PH PHASE

℄, CTR CENTER LINE, CENTER

P PLATE

SYMBOL LEGEND GENERAL NOTES

1. REFER TO LUMINAIRE SCHEDULE FOR FIXTURE TYPES, MOUNTING REQUIREMENTS, WATTAGE

& DETAILS.

2. WIRE LIGHT FIXTURE FROM ADJACENT JUNCTION BOX.

3. CONNECT NEAREST UN-SWITCHED HOT CONDUCTOR TO EMERGENCY BALLAST.

4. LIGHT FIXTURES ARE SCALED WITHIN THE DRAWINGS BASED ON ACTUAL DIMENSIONS.

5. REFER TO DRAWINGS FOR DIRECTIONAL ARROWS.

6. SUBSCRIPT INDICATES FIXTURES TO BE CONTROLLED.

7. HEIGHT MEASURED TO CENTER LINE OF THE BOX FROM THE FINISHED FLOOR.

8. NOT USED.

9. NEMA TYPE 'ND' NON-FUSED UNLESS NOTED 'F' (FUSED). USE HEAVY DUTY (HD) DEVICE FOR

480 VOLT.

10. SIZE TO THE EQUIPMENT BEING CONTROLLED.

11. PROVIDE H.O.A. & S.S. PUSHBUTTONS AS REQUIRED.

12. DOUBLE ARROWS INDICATES A DOUBLE FACE UNIT.

13. FOR WATER COOLER LOCATION, REFER TO DIAGRAM R002. FOR ALL OTHER LOCATIONS,

MOUNT AT +16" TO BOTTOM OF BOX FROM FINISHED FLOOR, OR AS NOTED.

14. ARROWS SHOWN ON DEVICE INDICATE AIMING DIRECTION.

15. COORDINATE WITH DOOR HARDWARE SUPPLIER.

16. MOUNT ON TRACK OF OVERHEAD DOOR, 6" FROM TOP OF DOOR, UNLESS OVERHEAD DOOR IS

A ROLL UP DOOR, THEN MOUNT PER MANUFACTURER'S INSTRUCTIONS.

17. INSTALL DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.

18. DASHED LINE INDICATES EQUIPMENT CLEARANCES. ARROW INDICATES FRONT OF RACK.

19. HEIGHT MEASURED TO BOTTOM OF THE DEVICE FROM FINISHED FLOOR.

20. PROVIDE MUD RING &/OR BOX COVER APPROPRIATE FOR DEVICE/FIXTURE SERVED.

21. REFER TO DIAGRAMS, ELEVATIONS, & SCHEDULES FOR CUSTOM ROUGH-IN REQUIREMENTS.

22. ROUGH-IN TO BE HORIZONTAL.

23. REFER TO MANUFACTURER'S RECOMMENDED CABLE REQUIREMENTS FOR EXACT CABLE

REQUIRED.

24. FOLLOW BICSI STANDARDS FOR CABLE ROUTING & DISTANCES.

25. SUBSCRIPT INDICATES NEMA CONFIGURATION.

26. USE A 4" X 4" BOX WITH A MUD RING TO MATCH THE DEVICE & INSTALLATION.

27. USE WITH POWER PACK.

28. PROVIDE UL LISTED DEVICE COMPATIBLE WITH THE FIRE ALARM PANEL/SYSTEM.

29. CAMERA TYPES ARE INDICATED INSIDE THE CAMERA SYMBOL.

30. SOLID BOX AROUND DEVICE INDICATES INSTALLED IN FLOOR. DASHED BOX AROUND DEVICE

INDICATES INSTALLED IN CEILING.

31. WALL DEVICES NOTED WITH A CHEVRON INDICATE THE PROPOSED INSTALLATION HEIGHT.

COORDINATE WITH MILLWORK SHOP DRAWINGS & ELEVATIONS FOR HEIGHT.

ELECTRICAL SHEET INDEX

SHEET NUMBER SHEET NAME

E001 ELECTRICAL TITLE SHEET

E101 LEVEL 1 ELECTRICAL FLOOR PLANS

ELECTRICAL GENERAL NOTES

1. GENERAL SCOPE & COMPLIANCE

A. INSTALL COMPLETE, OPERABLE ELECTRICAL SYSTEMS AS SHOWN AND SPECIFIED. BID

SHALL INCLUDE ALL WORK, MATERIALS, AND COORDINATION NECESSARY FOR A FULLY

FUNCTIONAL INSTALLATION.

B. ALL WORK SHALL COMPLY WITH THE NEC, NFPA 72, IBC/IFC, APPLICABLE LOCAL AND

STATE CODES, AHJ REQUIREMENTS, AND INDUSTRY STANDARDS.

C. ALL EQUIPMENT SHALL BE NEW, LISTED, AND LABELED BY A NATIONALLY RECOGNIZED

TESTING LABORATORY (E.G., UL, ETL) FOR ITS INTENDED USE.

D. ALL EQUIPMENT PROVIDED SHALL BE NEW, LISTED, AND LABELED BY A NATIONALLY

RECOGNIZED TESTING LABORATORY (NRTL).

E. FINAL INSTALLATION SHALL BE FREE OF DEFECTS AND APPROVED BY THE AHJ, OWNER,

ARCHITECT, AND ENGINEER.

F. THE ELECTRICAL SYSTEMS DEFINED BY THESE PLANS AND SPECIFICATIONS SHALL BE

CONSTRUCTED AS COMPLETE AND OPERABLE SYSTEMS AND BID WITH THIS INTENT.

G. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL APPLICABLE CONTRACT

DOCUMENTS, INCLUDING ARCHITECTURAL, MECHANICAL, STRUCTURAL, AND OTHER

TRADE DRAWINGS, TO COORDINATE LOCATIONS, DIMENSIONS, AND REQUIREMENTS. NO

ADDITIONAL COSTS WILL BE ALLOWED FOR FAILURE TO COORDINATE.

H. CONTRACTOR SHALL VERIFY ALL EQUIPMENT DIMENSIONS, ELECTRICAL LOADS

(VOLTAGE, PHASE, CONNECTION REQUIREMENTS, ETC.), AND ROUGH-IN LOCATIONS

BEFORE INSTALLATION. VERIFY NEC CODE CLEARANCES AROUND ALL ELECTRICAL

EQUIPMENT.

I. ALL WORK SHALL CONFORM TO LOCAL AND STATE CODES, THE LATEST EDITION OF THE

NEC, AND ALL APPLICABLE INDUSTRY STANDARDS.

J. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC/SCHEMATIC IN NATURE AND REPRESENT

THE GENERAL SCOPE OF WORK. RACEWAY ROUTING, UNLESS SPECIFICALLY SHOWN,

SHALL BE FIELD-DETERMINED IN COORDINATION WITH OTHER TRADES.

K. COORDINATE WITH ALL APPLICABLE SPECIFICATIONS, INCLUDING SECTION 265100

(16510) FOR REQUIRED COORDINATION MEETINGS WITH MECHANICAL AND CEILING

CONTRACTORS.

2. DRAWINGS & COORDINATION

A. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC, SHOWING GENERAL SCOPE AND INTENT

ONLY. EXACT ROUTING, BENDS, PULL BOXES, AND OTHER INSTALLATION DETAILS ARE

THE CONTRACTOR’S RESPONSIBILITY.

B. CONSULT ARCHITECTURAL REFLECTED CEILING PLANS FOR FIXTURE/DEVICE

LOCATIONS, MECHANICAL PLANS FOR COORDINATED PENETRATIONS, AND SHOP

DRAWINGS FOR EQUIPMENT DIMENSIONS.

C. COORDINATE WITH ALL OTHER TRADES BEFORE ROUGH-IN TO AVOID CONFLICTS WITH

DUCTWORK, PIPING, STRUCTURE, AND EQUIPMENT.

D. ARCHITECTURAL AND MECHANICAL PLANS ARE PART OF THE ELECTRICAL DOCUMENTS

WHERE THEY PERTAIN TO ELECTRICAL WORK.

E. NO ADDITIONAL COST WILL BE ALLOWED FOR FIELD CONFLICTS OR EQUIPMENT

DIMENSION VARIATIONS DUE TO FAILURE TO COORDINATE.

3. PRE-BID & PRE-INSTALLATION REQUIREMENTS

A. VISIT THE SITE, REVIEW ALL CONTRACT DOCUMENTS, AND VERIFY EXISTING

CONDITIONS BEFORE BIDDING.

B. NOTIFY THE ENGINEER IN WRITING OF ERRORS, OMISSIONS, OR CONFLICTS PRIOR TO

BID. CHANGES WILL BE ISSUED VIA PRE-BID ADDENDUM.

C. VERIFY ALL ELECTRICAL LOADS, VOLTAGES, PHASES, AND CONNECTION

REQUIREMENTS FOR NEW AND EXISTING EQUIPMENT TO BE REUSED.

D. OBTAIN AND REVIEW WIRING DIAGRAMS FROM EQUIPMENT SUPPLIERS BEFORE ROUGH-

IN.

4. CLEARANCES & CODE-REQUIRED SPACE

A. MAINTAIN NEC-REQUIRED WORKING CLEARANCES AROUND ALL ELECTRICAL

EQUIPMENT.

B. IF CLEARANCE ISSUES ARE FOUND, NOTIFY THE DESIGNER IMMEDIATELY. IF

DISCOVERED AFTER INSTALLATION, RELOCATE AT THE CONTRACTOR’S EXPENSE

UNLESS OTHERWISE DIRECTED.

C. DO NOT ALLOW FOREIGN PIPING, DUCTWORK, OR UNRELATED EQUIPMENT IN

ELECTRICAL ROOMS OR ABOVE/BELOW ELECTRICAL EQUIPMENT.

5. MATERIALS & INSTALLATION STANDARDS

A. MINIMUM CONDUIT SIZE: 3/4".

a. INTERIOR: EMT WITH SET-SCREW FITTINGS.

b. EXTERIOR: EMT WITH COMPRESSION GLAND TYPE FITTINGS.

c. UNDERGROUND: PVC (SCH40) WITH GRC ELBOWS AND RISERS WRAPPED IN

CORROSION-RESISTANT MATERIAL WHERE IN DIRECT SOIL CONTACT.

B. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTORS IN ALL

CONDUITS; CONDUIT SHALL NOT BE USED AS A GROUNDING CONDUCTOR.

C. COPPER CONDUCTORS, 600V RATED, THHN/THWN-2: #10 AWG AND SMALLER SOLID.

#8 AWG AND LARGER STRANDED. INCREASE CONDUCTOR SIZE TO #10 FOR 20A RUNS

OVER 125 FEET.

D. FLEXIBLE/SEALTITE CONDUIT LIMITED TO 6 FEET FOR FIXTURE AND MOTOR

CONNECTIONS AS NOTED OR VIBRATION-PRONE EQUIPMENT.

E. ALL EMPTY CONDUITS/RACEWAYS SHALL HAVE NYLON BUSHINGS AND 200 LB-RATED

PULL STRINGS.

F. SECURE CONDUIT AND BOXES TO STRUCTURE PER INDUSTRY STANDARDS. EXPOSED

CONDUIT SHALL BE PLUMB, LEVEL, PARALLEL TO BUILDING LINES, AND PAINTED TO

MATCH ADJACENT FINISHES IF VISIBLE.

G. CONDUITS/RACEWAYS SHALL BE CONCEALED WHERE PRACTICABLE. EXPOSED

CONDUIT/RACEWAY SHALL BE PAINTED TO MATCH ADJACENT SURFACES.

H. WIRING DEVICES SHALL BE WHITE WITH STAINLESS STEEL COVER PLATES UNLESS

OTHERWISE NOTED.

I. CONDUCTORS SHALL BE COPPER.

J. CAP AND LABEL ALL EMPTY CONDUIT TO REMAIN.

1. DEVICE & EQUIPMENT PLACEMENT

A. MOUNT WIRING DEVICES ABOVE BACKSPLASHES UNLESS SERVING UNDER-COUNTER

EQUIPMENT.

B. INSTALL SWITCHES, RECEPTACLES, AND CONTROLS AT ADA-COMPLIANT HEIGHTS.

C. OFFSET DEVICES ON OPPOSITE SIDES OF A WALL AT LEAST 12" TO REDUCE SOUND

TRANSMISSION.

D. COORDINATE FURNITURE LAYOUTS FOR FLOOR BOX AND POKE-THRU LOCATIONS

BEFORE ROUGH-IN.

E. LABEL ALL RECEPTACLE AND SWITCH FACEPLATES WITH CIRCUIT ID (XX-XX FORMAT).

F. PROVIDE TAMPER-RESISTANT RECEPTACLES AT ALL CODE-REQUIRED AND CHILD-

ACCESSIBLE LOCATIONS.

G. PROVIDE GFCI PROTECTION PER NEC, IN BATHROOMS, KITCHENS, OUTDOORS, WITHIN 6

FEET OF SINKS, AND WHERE REQUIRED FOR DIAGNOSTIC EQUIPMENT, TOOLS, OR

LIGHTING.

H. CIRCUITS EXTENDING OVER 70' FOR 120 VOLT AND 115' FOR 277 VOLT 20 AMP CIRCUITS

SHALL BE RUN WITH CONDUCTORS PER TABLE BELOW.

a. THESE ARE BASED ON MAXIMUM LENGTH OF CIRCUIT.

b. PERFORM VOLTAGE DROP CALCULATIONS AND PROVIDE CONDUCTOR SIZE TO

KEEP BRANCH CIRCUIT VOLTAGE DROP LESS THAN 3% WITH A 15 AMP LOAD.

c. CONTRACTOR SHALL ENSURE THAT THE INSTALLATION OF EACH BRANCH CIRCUIT

STAYS WITHIN 3% VOLTAGE DROP FOR A 15 AMP LOAD. IF

NECESSARY,CONTRACTOR SHALL INCREASE WIRE AND CONDUIT SIZE TO MEET

THE STANDARD AT NO ADDITIONAL COST TO OWNER.

I. MAINTAIN ELECTRICAL CONTINUITY TO REMAINING EQUIPMENT WHEN REMOVING

EXISTING EQUIPMENT.

J. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES (FLOORS, WALLS, CEILINGS) SHALL BE

SEALED WITH APPROVED FIRE-STOPPING MATERIALS TO MAINTAIN THE FIRE RATING.

K. EXTERIOR OUTLETS SHALL HAVE CAST COVERS WITH FLIP-TYPE LIDS UNLESS

OTHERWISE NOTED. ALL WP OUTLET HOODS SHALL BE EXTRA-DUTY, WHILE-IN-USE

TYPE, AND LOW-PROFILE WHERE PRACTICAL.

2. SPECIAL SYSTEMS

A. PROVIDE ADDRESSABLE FIRE ALARM SYSTEM PER NFPA 72, IBC/IFC, AND LOCAL CODES.

INCLUDE MONITORING OF SPRINKLER/TAMPER SWITCHES, AHU DUCT DETECTORS (>2000

CFM), PULL STATIONS AT EXITS, AND HEAT/SMOKE DETECTION AS SHOWN. SUBMIT

SHOP DRAWINGS FOR APPROVAL BEFORE INSTALLATION.

B. PROVIDE STRUCTURED CABLING FROM TELECOM/DATA/CATV OUTLETS TO THE MAIN

RACK/BOARD, WITH LABELING AT BOTH ENDS. INSTALL IN CONDUIT UNLESS ABOVE

ACCESSIBLE CEILINGS. USE PLENUM-RATED CABLE IN PLENUM SPACES.

C. PROVIDE HEAVY-DUTY FUSED DISCONNECTS.

D. SUBMIT SCALED LAYOUTS OF ELECTRICAL ROOMS (1/4" = 1') BASED ON FINAL

EQUIPMENT SUBMITTALS.

E. OBTAIN ALL WIRING DIAGRAMS FOR EQUIPMENT FROM SUPPLIERS BEFORE ROUGH-IN.

F. COORDINATE WITH EQUIPMENT SUPPLIERS FOR EXACT EQUIPMENT LOCATIONS AND

ELECTRICAL CONNECTIONS PRIOR TO ROUGH-IN.

G. THE ELECTRICAL CONTRACTOR SHALL MAKE FINAL EQUIPMENT CONNECTIONS UNLESS

OTHERWISE DIRECTED.

3. PENETRATIONS & SEALING

A. SEAL ALL PENETRATIONS OF FIRE-RATED FLOORS, WALLS, AND CEILINGS WITH

APPROVED FIRESTOP SYSTEMS TO MAINTAIN RATING.

B. ROOF PENETRATIONS FOR CONDUIT SHALL USE SEALED ROOF JACKS COMPATIBLE

WITH THE ROOF WARRANTY.

C. UNDERGROUND/UNDERFLOOR CONDUITS SHALL BE AT LEAST 24" BELOW GRADE/SLAB

UNLESS NOTED OTHERWISE.

D. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES (FLOORS, WALLS, CEILINGS) SHALL BE

SEALED WITH APPROVED FIRE-STOPPING MATERIALS TO MAINTAIN THE FIRE RATING.

4. TESTING, CLEANING, & TURNOVER

A. TEST AND VERIFY PROPER OPERATION OF ALL ELECTRICAL SYSTEMS AT COMPLETION.

B. CLEAN ALL FIXTURES, DEVICES, AND EQUIPMENT; REMOVE LABELS, DIRT, PAINT,

GREASE, AND DEBRIS BEFORE FINAL ACCEPTANCE.

C. PROVIDE ALL O&M MANUALS AND AS-BUILT DRAWINGS WITH WIRING DIAGRAMS INSIDE

EQUIPMENT AND IN THE PROJECT CLOSEOUT DOCUMENTS.

MAXIMUM LENGTH

20 AMP MINIMUM BRANCH CIRCUIT CONDUCTOR SIZING

BRANCH CIRCUIT VOLTAGE

CONDUCTOR LENGTH (FT) 120 VOLT 277 VOLT

<70 MIN. #12 AWG

70 - 115

115 - 170

170 - 270

271 - 380

>380

MIN. #12 AWG

MIN. #10 AWG MIN. #12 AWG

MIN. #8 AWG MIN. #10 AWG

MIN. #6 AWG MIN. #8 AWG

NOTE B MIN. #8 AWG

NOTE B NOTE B

ELECTRICAL GENERAL PROVISIONS

DESCRIPTION OF WORK: EXTENT OF ELECTRICAL WORK IS INDICATED ON DRAWINGS. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SUPERVISION AND SERVICE NECESSARY FOR A COMPLETE ELECTRICAL SYSTEM. WORK

INCLUDES, BUT IS NOT NECESSARILY LIMITED TO THE FOLLOWING ITEMS:

• ELECTRICAL CONNECTIONS FOR EQUIPMENT

• CONDUCTORS AND CABLES

• GROUNDING

• SUPPORTING DEVICES

• CONDUIT RACEWAYS

• ELECTRICAL BOXES AND FITTINGS

• RACEWAYS SYSTEMS

• ELECTRICAL SEISMIC CONTROL

• ELECTRICAL IDENTIFICATION

• SWITCHGEAR AND SWITCHBOARDS

• PANELBOARDS

• SERVICE ENTRANCE

• WIRING DEVICES

• OVERCURRENT PROTECTIVE DEVICES

• MOTOR AND CIRCUIT DISCONNECTS

• MOTOR STARTERS

• VARIABLE FREQUENCY DRIVES

• EMERGENCY ELECTRICAL SYSTEMS

• DEMOLITION

INTERPRETATION OF DRAWINGS AND SPECIFICATIONS: BEFORE BIDDING, CONTRACTOR SHALL FAMILIARIZE

THEMSELVES WITH THE DRAWINGS, SPECIFICATIONS AND PROJECT SITE.

VISIT THE SITE DURING THE BIDDING PERIOD TO DETERMINE EXISTING CONDITIONS AFFECTING ELECTRICAL AND

OTHER WORK, ALL COSTS ARISING FROM SITE CONDITIONS AND/OR PREPARATION SHALL BE INCLUDED IN THE

BASE BID. NO ADDITIONAL CHARGES WILL BE ALLOWED DUE TO INADEQUATE SITE INSPECTION.

QUALITY ASSURANCE: PERFORM WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC). COMPLY

WITH REQUIREMENTS FOR STATE AND LOCAL ORDINANCES. OBTAIN ALL PERMITS, INSPECTIONS, ETC FOR

AUTHORITY HAVING JURISDICTION (AHJ). EMPLOY ONLY QUALIFIED CRAFTSMEN WITH AT LEAST THREE (3) YEARS

OF EXPERIENCE. WORKMANSHIP SHALL BE NEAT, HAVE A GOOD MECHANICAL APPEARANCE AND CONFORM TO

BEST ELECTRICAL STATE CONTRACTING LICENSE. PROVIDE EQUIPMENT AND MATERIALS THAT ARE

UNDERWRITERS LABORATORIES INC. (UL) LISTED AND LABELED.

SUBMITTALS: AFTER THE CONTRACT IS AWARDED BUT PRIOR TO MANUFACTURE OR INSTALLATION OF ANY

EQUIPMENT, PREPARE COMPLETE SHOP DRAWINGS.

1. PROVIDE SUBMITTALS IN PORTABLE DOCUMENT FORMAT (PDF).

2. DOCUMENTS MUST BE ELECTRONICALLY BOOKMARKED AND KEYWORD SEARCHABLE USING

(HTTP://ADOBE.COM/ACROBAT) ADOBE ACROBAT OR BLUEBEAM REVU

(HTTP://BLUEBEAM.COM) FOR EACH RELEVANT SECTION. (I.E. INCLUDE ELECTRONIC BOOKMARKS

SEPARATION “LIGHT FIXTURES” FROM “PANELBOARDS”.)

3. ELECTRONICALLY HIGHLIGHT ALL OPTIONS FOR LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC.

MANUAL HIGHLIGHTING AND SCANNING OF THE DOCUMENTS IS NOT ACCEPTABLE AND WILL NOT BE

REVIEWED.

4. PROVIDE ONLY COMPLETED CUTSHEETS FOR ALL FIXTURE AND EQUIPMENT TYPES. BLANK

CUTSHEETS SUBMITTED WITH A SCHEDULE ARE NOT ACCEPTABLE AND WILL NOT BE REVIEWED.

5. A MAXIMUM OF ONE SUBMITTAL PER SPECIFICATION SECTION IS ALLOWED, IT IS NOT ACCEPTABLE TO

PROVIDE PRODUCT BY PRODUCT SUBMITTAL. SINGLE PRODUCT SUBMITTALS WILL NOT BE REVIEWED.

A. ELECTRICAL CONNECTIONS FOR EQUIPMENT

B. CONDUCTORS AND CABLES

C. GROUNDING

D. SUPPORTING DEVICES

E. CONDUIT RACEWAYS

F. ELECTRICAL BOXES AND FITTINGS

G. RACEWAYS SYSTEMS

H. ELECTRICAL SEISMIC CONTROL

I. ELECTRICAL IDENTIFICATION

J. SWITCHGEAR AND SWITCHBOARDS

K. PANELBOARDS

L. SERVICE ENTRANCE

M. WIRING DEVICES

N. OVERCURRENT PROTECTIVE DEVICES

O. MOTOR AND CIRCUIT DISCONNECTS

P. MOTOR STARTERS

6. PRODUCTS: PRODUCTS ARE SPECIFIED BY MANUFACTURE NAME, DESCRIPTION AND/OR CATALOG

NUMBER. PROVIDE PRODUCTS OF MANUFACTURERS SPECIFIED. SUBSTITUTIONS WILL BE CONSIDERED

IF A DUPLICATE WRITTEN APPLICATION IS SUBMITTED. NO MATERIAL MAY BE SUBSTITUTED AFTER THE

BID OPENING. PROVIDE BLOCK OUTS, SLEEVES, ETC. REQUIRED FOR INSTALLATION OF WORK

SPECIFIED.

7. RECORD DRAWINGS: MAINTAIN ON A DAILY BASIS, A COMPLETE SET OF RECORD DRAWINGS, REFLECTING AN ACCURATE DIMENSIONAL RECORD OF ALL BURIED OR CONCEALED WORK. MARK

RECORD DRAWINGS TO SHOW THE PRECISE LOCATION OF CONCEALED WORK AND EQUIPMENT,

INCLUDING CONCEALED OR EMBEDDED CONDUIT AND JUNCTION BOXES AND ALL CHANGES AND

DEVIATIONS IN THE WORK FROM THAT SHOWN ON THE CONTRACT DOCUMENTS.

8. OPERATION AND MAINTENANCE MANUALS: PROVIDE OPERATION AND MAINTENANCE DATA BOOKS FOR

ALL EQUIPMENT AND MATERIALS FURNISHED UNDER THIS DIVISION.

9. GUARANTEE: ENSURE THAT ELECTRICAL SYSTEMS INSTALLED UNDER THIS CONTRACT IS IN PROPER

WORKING ORDER AND IN COMPLIANCE WITH DRAWINGS, SPECIFICATIONS, AND/OR AUTHORIZED

CHANGES, WITHOUT ADDITIONAL CHARGE, REPLACE ANY WORK OR MATERIALS WHICH DEVELOP

DEFECTS, EXCEPT FROM ORDINARY WEAR AND TEAR, WITHIN ONE YEAR FROM THE DATE OF

SUBSTANTIAL COMPLETION.

10. FIRE PROTECTION SEALS: SEAL ALL PENETRATIONS FOR WORK OF THIS SECTION THROUGH FIRE

RATED FLOORS, WALLS, CEILINGS TO PREVENT THE SPREAD OF SMOKE, FIRE, TOXIC GAS, OR WATER

THROUGH THE PENETRATION EITHER BEFORE, DURING OR AFTER FIRE.

11. POWER OUTAGES: ALL POWER OUTAGES REQUIRED FOR EXECUTION OF THIS WORK SHALL OCCUR

DURING NON-STANDARD WORKING HOURS AND AT THE CONVENIENCE OF THE OWNER. INCLUDE ALL

COSTS FOR OVERTIME WORK IN BID.

12. EXCAVATING FOR ELECTRICAL WORK: LOCATE AND PROTECT EXISTING UTILITIES AND OTHER

UNDERGROUND WORK. PERFORM EXCAVATION IN A MANNER WHICH PROTECTS WALLS, FOOTINGS AND

OTHER STRUCTURAL MEMBERS.

13. CONCRETE BASES: PROVIDE 4” CONCRETE BASES FOR ELECTRICAL EQUIPMENT.

14. ROOF PENETRATIONS: PROVIDE ROOF JACK, SIZED TO FIT TIGHTLY TO RACEWAY FOR WEATHERTIGHT

SEAL.

ELECTRICAL CONNECTIONS FOR EQUIPMENT

1. VERIFY EXACT LOAD AND LOCATION OF ALL EQUIPMENT BEFORE ROUGH-IN FOR EACH ELECTRICAL

CONNECTION. PROVIDE COMPLETE ASSEMBLY OF MATERIAL, INCLUDING BUT NOT NECESSARILY

LIMITED TO, RACEWAYS, CONDUCTORS, CORDS, CORD CAPS, PLUGS, WIRING DEVICES, PRESSURE

CONNECTORS, TERMINALS (LUGS), ELECTRICAL INSULATION TAPE, HEAT-SHRINKABLE INSULATION

TUBING, CABLE TIES, SOLDERLESS WIRE NUTS, AND OTHER ITEMS AND ACCESSORIES AS NEEDED TO

COMPLETE SPLICES, TERMINATIONS, AND CONNECTIONS AS REQUIRED. FOR PERMANENTLY

INSTALLED FIXED EQUIPMENT, PROVIDE FLEXIBLE SEAL-TITE CONNECTIONS. FOR MOVABLE AND/OR

PORTABLE EQUIPMENT, PROVIDE WIRE DEVICE, CORD CAP, AND MULTI-CONDUCTOR CORD.

CONDUCTORS AND CABLES

1. PROVIDE FACTORY FABRICATED CONDUCTORS FOR SIZES, RATINGS, MATERIAL, AND TYPES

INDICATED FOR EACH SERVICE. PROVIDE COPPER CONDUCTORS, WITH THHN/THWN INSULATION. SIZE

ALL CONDUCTORS IN ACCORDANCE WITH NEC: MINIMUM SIZE TO BE #12 AWG. PROVIDE STRANDED

CONDUCTORS FOR #8 AWG AND LARGER.

2. THE FOLLOWING COLOR SCHEME SHALL BE USED:

3. MC CABLE:

A. MC CABLE IS ACCEPTABLE FOR ALL BRANCH CIRCUITS INSTALLED IN GYPSUM WALLBOARD

WALLS FROM THE HOME RUN DEVICE BOX TO THE LAST DEVICE BOX ON THE BRANCH CIRCUIT

AND ALL BOXES IN BETWEEN, FROM THE HOME RUN DEVICE BOX TO THE BRANCH PANEL, THE

CIRCUIT SHALL BE INSTALLED IN AN APPROVED RACEWAY. MC CABLE IS ACCEPTABLE FOR ALL

LIGHT FIXTURE WHIPS NOT LONGER THAN SIX FEET IN LENGTH. LOCATED IN REMOVABLE GRID

CEILINGS. MC CABLE IS UNACCEPTABLE TO BE INSTALLED FROM LIGHT FIXTURE TO LIGHT

FIXTURE. ALL MC CABLE SHALL BE PROVIDED WITH ANTI SHORT FITTINGS.

B. THE USE OF MC-PCS CABLE IS ACCEPTABLE FOR LIGHT FIXTURE WHIPS UTILIZING 0-10V

CONTROL SCHEMES, NOT LONGER THAN 72” IN LENGTH, LOCATED ABOVE REMOVABLE GRID

CEILINGS. ALL MC CABLE SHALL BE PROVIDED WITH ANTI-SHORT FITTINGS.

a. ACCEPTABLE MANUFACTURERS

• AFC – MC LUMINARY CABLE

• ENCORE – MC-LED LIGHTING CABLE

• SOUTHWIRE – MC-PCS DUO

GROUNDING

• PROVIDE GROUNDING AND BONDING OF ALL ELECTRICAL AND COMMUNICATION APPARATUS,

MACHINERY, APPLIANCES, BUILDING COMPONENTS, AND ITEMS REQUIRED BY THE NEC TO PROVIDE A

PERMANENT, CONTINUOUS LOW IMPEDANCE, GROUNDING SYSTEM. PROVIDE AN NEC

BONDING/GROUNDING CONDUCTOR IN ALL RACEWAYS USE FOR POWER DISTRIBUTION.

SUPPORTING DEVICES

• PROVIDE SUPPORTS, ANCHORS, SLEEVES AND SEALS AS REQUIRED FOR A COMPLETE RACEWAY

SUPPORT SYSTEM, INCLUDING BUT NOT LIMITED TO: CLEVIS HANGERS, RISER CLAMPS, C-CLAMPS, BEAM CLAMPS, ONE- AND TWO-HOLE CONDUIT STRAPS, OFFSET CONDUIT CLAMPS, EXPANSION

ANCHORS, TOGGLE BOLTS, THREADED RODS, U-CHANNEL STRUT SYSTEM, AND ALL OTHER

ASSOCIATED ACCESSORIES. INSTALL IN ACCORDANCE WITH MANUFACTURER’S WRITTEN

INSTRUCTIONS AND WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE SUPPORTING DEVICES

COMPLY WITH REQUIREMENTS. PROVIDE RIGID ATTACHMENT OF ALL FLOOR MOUNTED EQUIPMENT TO

THE FLOOR SLAB OR STRUCTURAL SYSTEM.

CONDUIT RACEWAYS

1. PROVIDE METAL CONDUIT, TUBING, AND FITTINGS OF TYPES, GRADES, SIZES, AND WEIGHTS (WALL

THICKNESS) AS REQUIRED; WITH MINIMUM TRADE SIZE OF 3/4”. INSTALL ELECTRICAL RACEWAY

SYSTEMS IN ACCORDANCE WITH MANUFACTURER’S WRITTEN INSTRUCTIONS AND APPLICABLE

REQUIREMENTS OF NEC AND NECA “STANDARD OF INSTALLATION” IN ACCORDANCE WITH THE

FOLLOWING:

A. FEEDERS: INSTALL FEEDERS RATED 100 AMPS AND GREATER, IN ELECTRICAL METALLIC CONDUIT

(EMT); WHERE BURIED BELOW GRADE, INSTALL IN CONCRETE ENCASED N0N-METALIC CONDUIT

OR DUCT (SCHEDULE 40 PVC).

B. BRANCH CIRCUITS, AND INDIVIDUAL EQUIPMENT CIRCUITS RATED LESS THAT 100 AMPS; INSTALL

IN ELECTRICAL METALLIC TUBING (EMT). WHERE LOCATED IN POURED WALLS, BELOW CONCRETE

SLAB-ON-GRADE, OR IN EARTH FILL, INSTALL IN NON-METALLIC PLASTIC DUCT (SCHEDULE 40

PVC). ENCASE NON-METALLIC PLASTIC DUCT 1-1/4” AND LARGER IN CONCRETE.

C. PROVIDE RIGID METAL CONDUIT (RMC) FOR ALL BENDS IN BURIED CONDUIT GREATER THAN 30

DEGREES. PROVIDE PROTECTIVE COATING FOR RIGID METAL CONDUIT BENDS.

D. INSTALL FLEXIBLE CONDUIT FOR CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER

ELECTRICAL EQUIPMENT WHERE SUBJECT TO MOVEMENT AND VIBRATIONS.

E. PROVIDE “OZ” EXPANSION FITTINGS ON ALL CONDUITS CROSSING BUILDING EXPANSION JOINTS, BOTH IN SLAB AND SUSPENDED.

F. DUCT BANKS” PROVIDE DUCT BANK CONSTRUCTION AS INDICATED USING 3000 PSI CONCRETE

WITH RED MARKER DYE. INSTALL #4 REINFORCING BAR IN EACH CORNER OF DUCT BANK.

PROVIDE MINIMUM OF 4” CONCRETE COVER ON ALL SIDES OF EXTERIOR CONDUITS.

ELECTRICAL BOXES AND FITTINGS

1. PROVIDE ONE PIECE GALVANIZED FLAT ROLLED SHEET STEEL INTERIOR OUTLET WIRING BOXES, CORROSION-RESISTANT CAST-METAL WEATHERPROOF OUTLET WIRING BOXES, CODE GAUGE SHEET

STEEL JUNCTION AND PULL BOXES, GALVANIZED CAST IRON CONDUIT BODIES, CORROSION-RESISTANT

PUNCH-STEEL BOX KNOCKOUT CLOSURES, CONDUIT LOCKOUTS AND MALLEABLE STEEL CONDUIT

BUSHINGS AND OFFSET CONNECTORS, AND ALL ACCESSORIES AS REQUIRED TO SUIT EACH

RESPECTIVE LOCATION AND INSTALLATION. FASTEN BOXES RIGIDLY TO SUBSTRATES OR STRUCTURAL

SURFACES TO WHICH ATTACHED, OR SOLIDLY EMBED ELECTRICAL BOXES IN CONCRETE OR MASONRY.

USE BAR HANGERS FOR STUD CONSTRUCTION.

2. FLOOR BOXES – PROVIDE LEVELING AND FULLY ADJUSTABLE FLOOR SERVICE RECEPTACLE OUTLETS

AND FITTINGS OF TYPE AND RATINGS AS INDICATED ON THE DRAWINGS. ALL BOXES SHALL COMPLY

WITH UL STANDARD UL514A.

RACEWAY SYSTEMS

1. EXTENT OF RACEWAYS IS INDICATED BY DRAWINGS AND SCHEDULES.

2. COMPLY WITH APPLICABLE PORTIONS OF NEMA STANDARDS PERTAINING TO RACEWAYS. COMPLY

WITH APPLICABLE PORTIONS OF UL SAFETY STANDARDS PERTAINING TO ELECTRICAL RACEWAY

SYSTEMS AND PROVIDE PRODUCTS AND COMPONENTS WHICH HAVE BEEN UL-LISTED AND LABELED.

COMPLY WITH NEC REQUIREMENTS AS APPLICABLE TO CONSTRUCTION AND INSTALLATION OF

RACEWAY SYSTEMS.

3. PROVIDE SURFACE RACEWAYS OF SIZES AND CHANNELS INDICATED. PROVIDE FITTINGS INDICATED

WHICH MATCH AND MATE WITH RACEWAY. PROVIDE RECEPTACLES ON CENTERS AS INDICATED ON

DRAWINGS OR AS DIRECTED BY ENGINEER.

4. PROVIDE CABLE TRAY SYSTEMS OF SIZES, TYPES AND CAPACITIES INDICATED, AND MEETING ALL

REQUIREMENTS OF NEMA VE-1. TRAYS TO BE PROVIDED INCLUDE BUT ARE NOT NECESSARILY LIMITED

TO THE FOLLOWING:

A. FITTINGS, GROUNDING STRAPS, CABLE FALLS, ETC.

5. INSTALL ELECTRICAL RACEWAYS WHERE INDICATED; IN ACCORDANCE WITH MANUFACTURERS

WRITTEN INSTRUCTIONS, APPLICABLE REQUIREMENTS OF NEC AND NECA “STANDARDS OF

INSTALLATION”, AND COMPLYING WITH RECOGNIZED INDUSTRY PRACTICES.

6. INSTALL ELECTRICAL RACEWAYS LEVEL AND SQUARE TO BUILDING ELEMENTS AND AT PROPER

ELEVATIONS/HEIGHTS.

ELECTRICAL SEISMIC CONTROL

1. PROVIDE SEISMIC CONTROL EQUIPMENT INCLUDING BUT NOT LIMITED TO: VIBRATION ISOLATORS, FLEXIBLE CONNECTIONS, RIGID STEEL FRAMES, ANCHORS, INSERTS AND ATTACHMENTS, SEISMIC

SNUBBER AND BRACING TO MEET THE REQUIREMENTS FOR THE PROJECT SITE AS DESIGNED BY A

PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED.

2. THE ABOVE REFERENCED ENGINEER SHALL DETERMINE SPECIFIC REQUIREMENTS FOR EQUIPMENT

ANCHORAGE AND RESTRAINTS, LOCATIONS AND SIZES BASED ON SHOP DRAWINGS FOR THE

ELECTRICAL EQUIPMENT WHICH HAVE BEEN SUBMITTED.

3. THE DIVISION 26 CONTRACTOR SHALL REQUIRE ALL EQUIPMENT SUPPLIER FURNISHED EQUIPMENT

THAT MEETS THE SEISMIC CODE, WITH BASES/SKIDS/CURBS DESIGNED TO RECEIVE SEISMIC BRACING

AND/OR ANCHORAGE.

4. SPRING ISOLATED EQUIPMENT: ALL VIBRATION ISOLATED EQUIPMENT SHALL BE MOUNTED ON RIGID

STEEL FRAMES OR CONCRETE BASES. EACH SPRING MOUNTED BASE SHALL HAVE A MINIMUM OF FOUR

ALL-DIRECTIONAL SEISMIC SNUBBERS THAT ARE DOUBLE ACTING AND LOCATED AS CLOSE TO THE

VIBRATION ISOLATORS AS POSSIBLE TO FACILITATE ATTACHMENT BOTH TO THE BASE AND THE

STRUCTURE.

5. NON-ISOLATED EQUIPMENT: THE DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR

THOROUGHLY REVIEWING ALL DRAWINGS AND SPECIFICATIONS TO DETERMINE ALL EQUIPMENT TO BE

RESTRAINED. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR CERTIFYING THAT THIS EQUIPMENT IS

MOUNTED AND BRACED.

6. CONDUIT: A RIGID CONDUIT SYSTEM SHALL NOT BE BRACED TO DISSIMILAR PARTS OF THE BUILDING

OR TWO DISSIMILAR BUILDING SYSTEMS THAT MAY RESPOND IN A DIFFERENT MODE DURING AN

EARTHQUAKE. EXAMPLE: WALLS AND A ROOF; SOLID CONCRETE WALL AND A METAL DECK WITH

LIGHTWEIGHT CONCRETE FILL. UNBRACED CONDUIT ATTACHED TO IN-LINE EQUIPMENT SHALL BE

PROVIDED WITH ADEQUATE FLEXIBILITY TO ACCOMMODATE DIFFERENTIAL DISPLACEMENTS. PROVIDE

LARGE ENOUGH PIPE SLEEVES THROUGH WALLS OR FLOORS TO ALLOW FOR ANTICIPATED

DIFFERENTIAL MOVEMENTS.

7. CABLE TRAY: CABLE TRAYS SHALL BE SUSPENDED FROM ROD HANGERS AND HANGERS THAT ARE 12”

IN LENGTH OR LONGER FROM POINT ROD ATTACHES TO TRAY, TO THE POINT ROD CONNECTS

LOCATED AS CLOSE TO THE VIBRATION ISOLATORS AS POSSIBLE TO THE SUPPORTING STRUCTURE

BOTH TO THE BASE AND TO THE VIBRATION ISOLATORS AS POSSIBLE TO FACILITATE ATTACHMENT

AND THE STRUCTURE.

8. NON-ISOLATED EQUIPMENT: THE DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR

THOROUGHLY REVIEWING ALL DRAWINGS AND SPECIFICATIONS TO DETERMINE ALL EQUIPMENT TO BE

RESTRAINED. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR CERTIFYING THAT THIS EQUIPMENT IS

MOUNTED AND BRACED.

ELECTRICAL IDENTIFICATION

1. PROVIDE ELECTRICAL IDENTIFICATION PRODUCTS FOR BURIED ELECTRICAL LINES, ARC-FLASH

HAZARD LABELS (ANSI Z535.4), SOURCE OF SUPPLY LABELS, AVAILABLE FAULT CURRENT LABELS AND

EMERGENCY OPERATING SIGNS TO EQUIPMENT INSTALLED AS PART OF THIS PROJECT.

2. COLOR ADHESIVE MARKING TAPE FOR RACEWAYS, WIRES AND CABLES: SELF-ADHESIVE VINYL TAPE

NOT LESS THAN 3 MILLS THICK BY 1” TO 2” IN WIDTH.

3. UNDERGROUND LINE MARKING TAPE: PERMANENT, BRIGHT COLORED, CONTINUOUS-PRINTED, PLASTIC

TAPE COMPOUNDED FOR DIRECT-BURIAL SERVICE NOT LESS THAN 6” WIDE BY 4 MILLS THICK.

4. ENGRAVED, PLASTIC LAMINATED LABELS, SIGNS AND INSTRUCTION PLATES: ENGRAVING STOCK

PLASTIC LAMINATE, 1/16” MINIMUM THICKNESS FOR SIGNS UP TO 20” SQUARE, OR 8” IN LENGTH; 1/8”

FOR LARGER SIZES. ENGRAVED LEGEND IN 1/4” HIGH WHITE LETTERS ON BLACK FACE.

5. PROVIDE LABELS ON COVER PLATES INDICATING SOURCE OF POWER (I.E. PANEL – CIRCUIT #) TO

COMPLY WITH NEC 408.4.

6. PROVIDE CIRCUIT DIRECTORY THAT CLEARLY IDENTIFIES EACH AND EVERY CIRCUIT, TO COMPLY WITH

NEC 408.

7. CONDUIT IDENTIFICATION

1. IDENTIFY RACEWAYS OF SYSTEMS WITH COLOR CODING. ACCEPTABLE MEANS OF COLOR

IDENTIFICATION ARE AS FOLLOWS:

A. COLORED ADHESIVE MARKING TAPE

B. FIELD PAINTED FITTINGS IE: COUPLINGS AND CONNECTORS

C. COLOR RACEWAYS FOR THE FOLLOWING SYSTEMS:

FIRE ALARM SYSTEM: RED

SOUND/IC: BLUE

TELEPHONE: YELLOW

DATA: GREEN

SECURITY: ORANGE

1. IDENTIFY JUNCTION, PULL AND CONNECTION BOXES

A. PROVIDE COVERPLATES FOR SYSTEMS JUNCTION, PULL AND CONNECTIONS BOXES

PAINTED TO MATCH REQUIREMENTS ABOVE.

B. FOR POWER AND LIGHTING JUNCTION BOXES LABEL WITH IDENTITY OF CONTAINED

CIRCUITS.

WIRING DEVICES

1. PROVIDE SPEC GRADE FACTORY-FABRICATED WIRING DEVICES, IN TYPE, AND ELECTRICAL RATINGS

FOR APPLICATIONS INDICATING AND COMPLYING WITH NEMA STDS PUB NO. WD-1. PROVIDE HEAVY

DUTY SPECIFICATION GRADE, 20-AMPERES RATED, GROUNDING TYPE CONVENIENCE OUTLETS.

PROVIDE 20-AMPRESE RATED TOGGLE SWITCHES. CONSTRUCT WIRING DEVICE OF HEAVY-DUTY HIGH

IMPACT NYLON AND PROVIDE COVER PATES TO MATCH. PROVIDE DEVICES AND COLORS SELECTED BY

ARCHITECT.

2. PROVIDE THE FOLLOWING:

A. CONTROLLED RECEPTACLE - NEMA 5-20R TO COMPLY WITH NEC 406.3(F).

B. GROUND FAULT INTERRUPTER - NEMA 5020R WITH 5 MILIAMPERIS GROUND FAULT TRIP LEVEL.

C. USB RECEPTACLE - NEMA 5-20R WITH (2) USB, 5VDC, 2.0 AND 3.0 TYPE A AND TYPE C PORTS.

D. TAMPER RESISTANT RECEPTACLE - NEMA 5-20R TO COMPLY WITH NEC 406.12.

E. WEATHER-RESISTANT RECEPTACLE - NEMA 5-20R TO COMPLY WITH NEC 406.9.

F. WEATHER PROTECTIVE DEVICE ENCLOSURE - PROVIDE IN-USE COVER TO COMPLY WITH NEC

406.9.

OVERCURRENT PROTECTIVE DEVICES

1. PROVIDE OVERCURRENT PROTECTIVE DEVICES OF THE SAME MANUFACTURER AS THE SWITCHBOARD

AND/OR PANELBOARD MANUFACTURER. PROVIDE FACTORY ASSEMBLED DEVICES OF AMPERAGE,

VOLTAGE, AND RMS INTERRUPTING RATING SHOWN. PROVIDE DEVICES AS FOLLOWS:

A. MOLDED CASE THERMAL TRIP CIRCUIT BREAKERS:

a. PROVIDE FACTORY-ASSEMBLED BOLT-ON MOLDED CASE CIRCUIT BREAKER WITH

PERMANENT THERMAL TRIP AND ADJUSTABLE INSTANTANEOUS MAGNETIC TRIP IN EACH

POLE. SERIES RATING IS NOT ACCEPTABLE. CONSTRUCT BREAKERS FOR MOUNTING AND

OPERATING IN ANY PHYSICAL POSITION AND IN AN AMBIENT TEMPERATURE OF 40 DEGREES

C.

b. CIRCUIT BREAKERS 15 AMPS THROUGH 599 AMPS SHALL BE MOLDED CASE THERMAL

CIRCUIT BREAKERS

B. MOLDED CASE SOLID STATE CIRCUIT BREAKERS

a. PROVIDE FACTORY ASSEMBLED BOLT-ON MOLDED CASE CIRCUIT BREAKERS UL LISTED

FOR APPLICATION AT 100% OF THEIR RATED CONTINUOUS AMPERE RATING.

b. CIRCUIT BREAKERS 600 AMPS THROUGH 1199 AMPS SHALL BE MOLDED CASE SOLID-STATE

CIRCUIT BREAKERS.

c. SOLID-STATE TRIP MECHANISMS SHALL HAVE THE FOLLOWING FUNCTIONS:

ADJUSTABLE LONG TIME AMPERE RATING; ADJUSTABLE LONG TIME DELAY; SHORT TIME

PICK-UP; ADJUSTABLE SHORT TIME DELAY; ADJUSTABLE INSTANTANEOUS PICK-UP.

C. INSULATED CASE CIRCUIT BREAKERS

a. PROVIDE FACTORY ASSEMBLED BOLT-ON INSULATED CASE CIRCUIT BREAKERS WITH SOLID-

STATE TRIP APPLICATION AT 100% OF THEIR CONTINUOUS AMPERE RATING.

b. CIRCUIT BREAKERS 1200 AMPS AND LARGER SHALL BE INSULATED CASE CIRCUIT

BREAKERS.

MOTOR AND CIRCUIT DISCONNECTS

1. PROVIDE HEAVY-DUTY TYPE SAFETY SWITCHES; FUSIBLE OR NON-FUSIBLE AS INDICATED. PROVIDE

SWITCHES RATED AT 600 VOLTS, 60 HZ.; INCORPORATING QUICK-MAKE, QUICK-BREAK TYPE

MECHANISMS. EQUIP WITH OPERATING HANDLE THAT IS CAPABLE OF BEING PADLOCKED IN THE OFF

POSITION. PROVIDE NEMA ENCLOSURE RATINGS BASED ON LOCATION OF INSTALLATION.

MOTOR STARTER

1. PROVIDE FACTORY ASSEMBLED, AC-NON-RESERVING MAGNETIC STARTERS RATED AT 600V WITH

THERMAL OVERLOAD PROTECTION IN ALL PHASES. MOUNT HAND-OFF-AUTO SWITCH, RED PILOT LIGHT, AND RESET BUTTON IN FACE OF ENCLOSURE. PROVIDE NEMA ENCLOSURES RATINGS BASED ON

LOCATION OF INSTALLATION.

DEMOLITION

1. PROVIDE DEMOLITION WORK AS INDICATED BY DRAWINGS. THE INTENT OF THE DRAWINGS IS TO

INDICATE MAJOR ITEMS AFFECTED AND NOT TO SHOW EVERY DEVICE AFFECTED BY DEMOLITION

WORK.

A. THE NEW ELECTRICAL EQUIPMENT AND APPARATUS SHALL BE COORDINATED AND CONNECTED

INTO THE EXISTING SYSTEM AS REQUIRED.

a. THE EXISTING ELECTRICAL DEVICES, CONDUIT AND/OR EQUIPMENT THAT FOR ANY REASON

OBSTRUCTS CONSTRUCTION SHALL BE RELOCATED.

b. ALL EXISTING ELECTRICAL EQUIPMENT AND SYSTEMS IN PORTIONS OF THE BUILDING NOT

BEING REMODELED SHALL BE KEPT OPERATIONAL, IN SERVICE AND IN WORKING CONDITION

THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. RESTORE ANY CIRCUITS AND SYSTEMS

INTERRUPTED.

c. EXISTING RACEWAY MAY BE RE-USED WHERE POSSIBLE IN PLACE. ALL CIRCUITS AND WIRE

THAT ARE NOT RE-USED SHALL BE REMOVED BACK TO PANEL BOARD. WHERE IT SHALL BE

LABELED AS SPARE. RE-USED RACEWAY SHALL MEET ALL REQUIREMENTS FOR NEW

INSTALLATION.

ELECTRICAL SPECIFICATIONS

CONDUCTOR 240/120 V SYSTEM 208/120 V SYSTEM 480/277 V SYSTEM

PHASE A

PHASE B

PHASE C

SHARED/SINGLE

NEUTRAL

NEUTRAL A

(DEDICATED)

NEUTRAL B

(DEDICATED)

NEUTRAL C

(DEDICATED)

ISOLATED GROUND

EQUIPMENT GROUND

BLACK

RED

BLUE

WHITE

WHITE W/ BLACK

STRIPE

WHITE W/ RED

STRIPE

WHITE W/ BLUE

STRIPE

GREEN W/ YELLOW

STRIPE

GREEN

BLACK

RED

BLUE

WHITE

WHITE W/ BLACK

STRIPE

WHITE W/ RED

STRIPE

WHITE W/ BLUE

STRIPE

GREEN W/

YELLOW STRIPE

GREEN

BROWN

ORANGE

YELLOW

GRAY

GRAY W/ BROWN

STRIPE

GRAY W/ ORANGE

STRIPE

GRAY W/ YELLOW

STRIPE

GREEN W/ YELLOW

STRIPE

GREEN

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

Jason Van Ausdal

09/03/2026

VISTOR WALK-IN

OFFICE

WORK AREA /

STORAGE

UTILITY ROOM

RECEIVING AREA/

EQUIPMENT

HOLDING

COOL STORAGE

STORAGE

STORAGE

T

T

T

VISTOR WALK-IN

OFFICE

WORK AREA /

STORAGE

UTILITY ROOM

RECEIVING AREA/

EQUIPMENT

HOLDING

COOL STORAGE

STORAGE

STORAGE

T

T

T

D1

D1

D1

UH-1

UH-1

UH-1

P1

P1

P1

L I C

E N

S E D

P

ROFESS IONA

L

E N

G I N

E E

R

14275529

S

T A

T E OF U

TA

H

SANG TRUONG

No.

Project #: 260447

DFCM APPROVAL STAMP

181 East 5600 South Murray, UT 84107

801.530.3148 T

801.530.3150 F

A

B

C

D

E

1 2 3 4 5 6

07/16/2026

260447

ST

REVISIONS

SHEET CONTENTS

RESOLUT PROJECT #:

CHECKED BY:

DRAWN BY:

CURRENT/ISSUE DATE:

Resolut Group, 2025

Original drawings remain the property of the Engineer and as such the Engineer retains total ownership and control. The design represented by these drawings are sold to the client for a one time use, unless otherwise agreed upon in writing by the

Engineer.

C

U S

H

W A

R E

H O

U S

E U

N

IT

H E

A T

E R

S R

E P

L A

C E

M E

N T

E a s t

C e n te r S tr e e t

P ro v o

U ta h

SE

LEVEL 1 ELECTRICAL

FLOOR PLANS

E101

1/8" = 1'-0"

LEVEL 1 ELECTRICAL DEMOLITION PLAN

ELECTRICAL DEMOLITION NOTES

1. REFERENCE & COORDINATION

A. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR DEMOLITION AND

CONSTRUCTION PHASES. COORDINATE ALL ELECTRICAL WORK WITH GENERAL

CONSTRUCTION REQUIREMENTS, DOOR RELOCATIONS, AND WALL MODIFICATIONS.

B. EXISTING DEVICES/EQUIPMENT SHOWN IN GRAY ARE EXISTING TO REMAIN. PRESERVE

AND PROTECT.

C. CONTRACTOR TO COORDINATE WITH OWNER FOR ITEMS TO BE SALVAGED PRIOR TO

DEMOLITION. CONTRACTOR RESPONSIBLE FOR DISPOSING OF ANY MATERIAL THAT THE

OWNER DOES NOT WANT TO KEEP.

D. DEVICES SHOWN ON DEMOLITION SHEETS ARE GATHERED FROM AS-BUILT DRAWINGS

AND FIELD…