General Services Administration Preventive Maintenance Guide Effective Date: October, 2012

Public Buildings Service

PUBLIC BUILDINGS

MAINTENANCE STANDARDS

Final October 1, 2012 Rev 3 This Maintenance Standard is divided into the following Sections:

Table of Contents 4Section 1: Introduction and Maintenance Standard List

4General Overview:

4Maintenance Standard Numbers:

4Equipment Attributes:

5Good Maintenance Practices

6Electrical test equipment.

7Suitability of Test Equipment

7Tools:

10Section 2: Maintenance Standard Listing

657Appendix A: NETA Qualifications, Responsibilities and Safety

662Appendix B: NETA Electrical Test Frequencies

666Appendix C: Equipment Attributes Lists

679Appendix D: Maintenance Standard List Key

695Appendix E RFID Tag Procedures

698Appendix F: Point Naming Convention

705Appendix G: Universal Waste Guide (GSA)

706Appendix H: Refrigerant Management Guide (GSA)

707Appendix I: Underground Storage Tank Regulatory Requirements (GSA)

708Appendix J: Predictive Maintenance and Toolsets

Public Buildings Service

Maintenance Practices and General

Information for Federal Buildings Section 1: Introduction and Maintenance Standard List General Overview:

The objective of these maintenance standards is to provide helpful instruction in the performance of preventive and predictive maintenance techniques, in order to maximize the efficiency of operation and the useful life of equipment, systems, and structures, and to provide reliable and suitable conditions for the building tenants. They are generic in nature and not intended to substitute for manufacturer's instructions or to apply uniformly across all types and configurations of equipment and systems installed in Federal buildings. Therefore, maintenance staffs and contractors must exercise a measure of caution in the application of these standards.

Maintenance Standard Numbers:

The GSA Maintenance standard is arranged by sections according to building equipment groups or building components. A four (4) tier system is used to easily identify the type of building group, equipment type and frequency for performing maintenance on these systems. The format is as follows:

1. Tier 1 identifies the building component system or type of building equipment group, i.e. Electrical (ELEC), Heating Ventilation, Air Conditioning (HVAC)

2. Tier 2 identifies the type of equipment, i.e. Transformer (TRN), Chiller (CLR)

3. Tier 3 further defines the equipment by number when there is more than one type, i.e. Centrifugal Chiller (04), Absorption Chiller (05)

4. Tier 4 defines the frequency for the specific maintenance task to be performed, i.e. Monthly (01M), Quarterly (03M) Semi-annually (06M), Annually (01Y)

The Standard number appears in the format of: HVAC-CLR-04-01Y which identifies the standard as: a HVAC System chiller of type 4 (centrifugal) to be performed annually.

Equipment Attributes:

Appendix D contains Equipment Attributes lists that the Operations and Maintenance Contractor is required to collect data from each piece of equipment. This task is part of the maintenance requirements for each building in order for GSA to have an accurate and up to date database of each building’s equipment. Equipment is listed with the values and the type of data that shall be collected. Attribute fields have been created in the CMMS for each equipment type. Once the data has been collected it shall be input into the CMMS by the contractor.

Good Maintenance Practices The following is a list of good practices to observe when performing maintenance.

5. Machinery and equipment shall be cleaned and touch up painted as necessary to restore surface condition and inhibit corrosion.

6. Install replacement parts that are appropriate to the equipment, its operating conditions, and the required performance levels. Substandard components shall not be used in government equipment. All parts, materials, components, and replaceable inserts used in the maintenance and repair of equipment and systems in Federally controlled space shall be new, suitable for the type and severity of service, and meet safety performance codes and standards. Refurbished parts are not to be used unless approved by proper authority. Normal rework of machinery casings, tube sheets, shafts, and other similar types of work, where repair to a major structural item is accepted industry practice, is permitted unless safety and performance are adversely affected.

7. Proper documentation through a system of record keeping is required; if available, a Computerized Maintenance Management System (CMMS) shall be used. The types of records authorized may be preprinted government forms or locally produced forms of an appropriate format. It is paramount to maintain equipment history records to facilitate decision making throughout the life of the equipment. Predictive maintenance frequently entails trending analysis, so a history of the test data on the equipment is required.

8. The intent of language such as "check", "inspect", etc., is to determine the status of the check point item and to take appropriate corrective action to eliminate any deficiencies found on the spot if within contract limits if possible and or to notify GSA as soon as practicable when repair exceeds contract limits or cannot be repaired on the spot. If additional calibration, adjustment, replacement of parts and fluids, and other work are necessary, that work shall be accomplished or scheduled for future action.

9. Maintenance work shall be scheduled so as to minimize the disruption to building occupants and operations. Proper notification and coordination shall be made when maintenance work necessitates shutting down equipment or otherwise terminating services to the building occupants.

10. Equipment under warranty shall be maintained in accordance with warranty instructions and conditions. Warranty provisions will be stringently complied with during the periods that they apply.

11. When fixed fire protection systems are temporarily removed or disconnected from service, they must be reconnected and/or placed back into service at the end of each work day unless otherwise authorized. Fixed fire protection systems include equipment and devices whose function is to prevent, detect, or control fires, or transmit signals related to fire emergencies. The status of major equipment or systems not operating or that become non operational during the workday, or any system or equipment item, including elevators, not operational by the official working hours start time, shall be reported to the proper authority (buildings manager or contracting officer's representative.) Security and fire alarm system malfunctions must be reported immediately to the GSA call center. All fire related equipment operation and maintenance shall follow the appropriate National Fire Protection Association (NFPA) code or standard, such as NFPA 72 the National Fire Alarm Code.

12. When performing maintenance on equipment that requires working with (CFC’s) refrigerants. Those working on the equipment must maintain the applicable certifications for working on such equipment. All applicable local, state, federal guidelines and regulations must be adhered to with respect to documentation, handling and disposal of refrigerants.

13. When performing maintenance in space that may be occupied or accessible during the performance of the work, provide adequate steps for the protection of the public and employees.

14. Trash, debris, and wastes from contract work inside buildings shall be removed daily. Exceptions shall be approved in advance. Premises shall be left neat and clean after each work shift so that the Government business can proceed without interruption the next regular workday. All waste material shall be properly disposed of in accordance with applicable Federal, State and local regulations.

15. All equipment and systems shall be maintained at a level, fair wear and tear excepted, to assure that the building(s) are operated in an efficient and economical manner.

16. All work, including contact with and handling of hazardous materials and wastes, the disturbance or dismantling of structures or equipment containing hazardous materials and/or the disposal of ordinary and hazardous materials and wastes shall comply with applicable Federal requirements including 29 CFR 1910/1926, 40 CFR 260-265, 40 CFR 61, 49 CFR 171-179, and applicable state and municipal safety and environmental requirements. Submit copies of permits, certificates, and manifests that indicate hazardous waste has been disposed of in compliance with the regulations. Where there is a conflict between applicable regulations, the most stringent shall apply.

Electrical test equipment.

All electrical test equipment shall conform to the following requirements, outlined in ANSI/NETA MTS-2011.

Suitability of Test Equipment

17. All test equipment shall meet the requirements in paragraph b) Test Instrument Calibration and be in good mechanical and electrical condition.

18. Field test metering used to check power system meter calibration must be more accurate than the instrument being tested.

19. Accuracy of metering in test equipment shall be appropriate for the test being performed.

20. Wave shape and frequency of test equipment output waveforms shall be appropriate for the test to be performed and the equipment to be tested.

21. Test Equipment calibration The testing organization shall have a calibration program which assures that all applicable test instruments are maintained within rated accuracy for each test instrument calibrated.

The firm providing calibration service shall maintain up-to-date instrument calibration instructions and procedures for each test instrument calibrated.

The accuracy shall be directly traceable to the National Institute of Standards and Technology (NIST).

Instruments shall be calibrated in accordance with the following frequency schedule:

i. Field instruments: analog and digital, 12 month maximum.

ii. Laboratory instruments: 12 month maximum.

iii. Leased specialty equipment: 12 month maximum.

Dated calibration labels shall be visible on all test equipment.

Records which show date and results of instruments calibrated or tested must be kept up to date.

Calibrating standard shall be of better accuracy than that of the instrument tested.

Tools:

The following tool groups are referenced within this standard. The lists serve as guides for supplying maintenance personnel with tools. Basic and trade tools required will vary depending on equipment served and on individual preferences. Special recommended tools, materials, and equipment are listed in the individual standards as required.

STANDARD TOOLS - BASIC

(All Trades)

22. Standard and Phillips head screw drivers-various sizes.

23. Pliers-vise grip (2), slip-joint, needle-nose, diagonal,

24. cutting pliers, side cutters.

25. Ball peen hammer.

26. Hack saw and spare blades.

27. 3/8' drive socket set and ratchet.

28. Small set of Allen wrenches.

29. Assorted center punches, drift punches, and steel chisel.

30. 12' measuring tape.

31. Crescent wrenches 4" to 8".

32. Open and box end wrenches ¼" to ¾".

33. File.

34. Pipe wrenches to 14".

35. Small level and square.

36. Pocket knife.

37. Flashlights.

38. Grease guns and oilers

39. Wire brush.

40. Extension cord and inspection lights.

41. Various cleaning tools - brushes, scrapers, etc.

42. Emery cloth.

TOOL GROUP A

43. Standard tools - basic

44. Refrigeration - gauges

45. Leak detector-electronic or halogen

46. Pocket thermometer

47. Clamp on meter (volt - ohm - amp meter)

48. Flaring tool

49. Tubing cutters

50. Packing kit and packing

51. Crescent wrenches to 14"

TOOL GROUP B

52. Standard tools - basic

53. Insulated pliers and screwdrivers

54. Wire strippers

55. Wire crimpers

56. Voltmeter - Ohmmeter - Milliammeter

57. Clamp on meter(volt - ohm - amp meter)

58. Soldering kit

59. 1/8" 25' fish tape

60. Burnishing tool

TOOL GROUP C

61. Standard tools - basic

62. Pipe wrenches to 24"

63. Tubing cutters

64. Flaring tool

65. Small acetylene outfit

66. Packing tool kit and packing

67. ¾" socket set

68. Crescent wrenches to 14"

Section 2: Maintenance Standard Listing

General Services Administration
MAINTENANCE TIME STANDARDS
Office of Real Property Management and Safety
Standard #
Equipment Item
Effective Date
Frequency

ARCHITECTURAL AND STRUCTURAL

ARCS-BAR-01-06M
Security Bollards and Barricades
Oct-1
Semi-annually
ARCS-DAV-01-01Y
Davits
Oct-1
Annually
ARCS-DOR-01-06M
Door, Power Operated
Oct-1
Semi-annually
ARCS-DOR-02-03M
Door, Hydraulic, Electric or Pneumatic Operated
Oct-1
Quarterly
ARCS-DOR-03-06M
Door, Manual, Overhead
Oct-1
Semi-annually
ARCS-DOR-04-06M
Door, Main Entrance
Oct-1
Semi-annually
ARCS-FPL-01-01M
Fireplace
Oct-1
Monthly
ARCS-FPL-02-01Y
Incinerator
Oct-1
Annually
ARCS-LND-01-06M
Fountain, Memorial or Decorative
Oct-1
Semi-annually
ARCS-LND-02-06M
Gates and Fences, Security and Access
Oct-1
Semi-annually
ARCS-LND-03-01Y
Lawn Sprinklers (per nozzle)
Oct-1
Annually
ARCS-LND-04-03M
Flag Pole, Electric and Manual
Oct-1
Quarterly
ARCS-LND-05-06M
Lawn Mower and Edger
Oct-1
Semi-annually
ARCS-MHL-01-01Y
Manhole, Electrical
Oct-1
Annual
ARCS-MHL-02-03M
Manhole, Sewer
Oct-1
Quarterly
ARCS-MHL-03-06M
Manhole, Water/Steam/Fuel Oil (also includes hot water, chilled water, and condenser water)
Oct-1
Semi-annually
ARCS-RFS-01-06M
Roof Inspection - Built-up type (per square, or 100 sq. ft.)
Oct-1
Semi-annually
ARCS-RFS-02-06M
Roof Inspection - Shingle Type (per 100 sq. ft.)
Oct-1
Semi-annually
ARCS-RFS-03-03M
Extensive and Intensive Vegetative Roof
Oct-1
Quarterly
ARCS-SCT-01-03M
Key Card System
Oct-1
Quarterly
ARCS-SCT-02-01Y
Parking Arm Gates
Oct-1
Annually
ARCS-STR-01-01Y
Lightning Protection (per down conductor)
Oct-1
Annually
ARCS-SWM-01-01M
Storm Water Management: Ponds (Dry and Wet)
Oct-1
Monthly
ARCS-SWM-02-01M
Storm Water Management: Basins
Oct-1
Monthly
ARCS-SWM-03-01M
Storm Water Management: Trenches
Oct-1
Monthly
ARCS-SWM-04-01M
Storm Water Management: Dry Wells
Oct-1
Monthly
ARCS-SWM-05-01M
Storm Water Management: Permeable Pavers
Oct-1
Monthly
ARCS-SWM-06-01M
Storm Water Management: Hydrodynamic Structures (i.e. swales)
Oct-1
Monthly
ARCS-SWM-07-01M
Storm Water Management: Biofiltration
Oct-1
Monthly
ARCS-WIN-01-01Y
Window Washing Scaffold, Power Operated
Oct-1
Annually

CHILD CARE

CHLD-EQP-01-01M
Child Care Equipment
Oct-1
Monthly
CHLD-SEC-01-01M
Child Care Secured Perimeter Systems
Oct-1
Monthly
CHLD-SPC-01-01M
Child Care Areas
Oct-1
Monthly

CLEANING

CLNG-SCB-01-03M
Scrubbing Machine, Battery or Propane Powered
Oct-1
Quarterly
CLNG-SNO-01-01Y
Snow Blower
Oct-1
Annually
CLNG-SWP-01-06M
Sweeper
Oct-1
Semi-annually
CLNG-TCP-01-01Y
Trash Compactor
Oct-1
Annually
CLNG-VAC-01-06M
Vacuum Cleaner, Heavy Duty, Tank Type
Oct-1
Semi-annually
CLNG-VAC-02-01Y
Vacuum System, Centralized
Oct-1
Annually

CONTROLS

CTRL-DDC-01-01W
BAS Server
Oct-1
Weekly
CTRL-DDC-01-01M
BAS Server
Oct-1
Monthly
CTRL-DDC-01-03M
BAS Server
Oct-1
Quarterly
CTRL-DDC-01-01Y
BAS Server
Oct-1
Annually
CTRL-DDC-02-01W
BAS Server Client Workstation
Oct-1
Weekly
CTRL-DDC-02-01M
BAS Server Client Workstation
Oct-1
Monthly
CTRL-DDC-02-03M
BAS Server Client Workstation
Oct-1
Quarterly
CTRL-DDC-02-01Y
BAS Server Client Workstation
Oct-1
Annually
CTRL–DDC-03-03M
Network, Management Level
Oct-1
Quarterly
CTRL–DDC-03-01Y
Network, Management Level
Oct-1
Annually
CTRL–DDC-04-03M
Network, Building Level
Oct-1
Quarterly
CTRL–DDC-04-01Y
Network, Building Level
Oct-1
Annually
CTRL–DDC-05-01Y
Field Panel
Oct-1
Annually
CTRL–DDC-06-01Y
Controller
Oct-1
Annually
CTRL-DDC-07-01Y
Controls, Sensors Electronic
Oct-1
Annually
CTRL-DDC-08-01M
Alarm Maintenance
Oct-1
Monthly
CTRL-DDC-09-06M
BAS Wireless Electronic/Pneumatic End Devices (Thermostats)
Oct-1
Semi-annually
CTRL-DDC-09-01Y
BAS Wireless Electronic/Pneumatic End Devices (Thermostats)
Oct-1
Annually
CTRL-END-01-01Y
End Devices
Oct-1
Annually
CTRL-PNU-01-06M
Control Air System
Oct-1
Semi-annually
CTRL-PNU-02-06M
Receiver Controller
Oct-1
Semi-annually
CTRL-PNU-03-03M
Filter, Control Air
Oct-1
Quarterly

ELECTRICAL

ELEC-ATS-01-01M
Automatic Transfer Switch, per NFPA 110
Oct-1
Monthly
ELEC-ATS-01-01Y
Automatic Transfer Switch
Oct-1
Annually
ELEC-BDT-01-01Y
Metal-Enclosed Busways, Thermographic Survey
Oct-1
Annually
ELEC-BDT-01-03Y
Metal-Enclosed Busways
Oct-1
3-Year
ELEC-CAP-01-01Y
Capacitors, Thermographic Survey
Oct-1
Annually
ELEC-CAP-01-03Y
Capacitors
Oct-1
3-Year
ELEC-CAP-02-01Y
Reactors-Dry-Type, Thermographic Survey
Oct-1
Annually
ELEC-CAP-02-03Y
Reactors – Dry-Type
Oct-1
3-Year
ELEC-CAP-03-01M
Reactors – Liquid-Filled, Oil Leakage
Oct-1
Monthly
ELEC-CAP-03-01Y
Reactors – Liquid-Filled, Oil Sampling
Oct-1
Annually
ELEC-CAP-03-03Y
Reactors – Liquid-Filled
Oct-1
3-Year
ELEC-CBL-01-01Y
Cables, Low-Voltage, Thermographic Survey
Oct-1
Annually
ELEC-CBL-01-03Y
Cables, Low-Voltage
Oct-1
3-Year
ELEC-CBL-02-01Y
Medium- and High-Voltage Cables, Thermographic Survey
Oct-1
Annually
ELEC-CBL-02-03Y
Medium- and High-Voltage Cables
Oct-1
3-Year
ELEC-CKB-01-01Y
Circuit Breakers, Air, Insulated-Case/Molded-Case
Oct-1
Annual
ELEC-CKB-01-03Y
Circuit Breakers, Air, Insulated-Case/Molded-Case
Oct-1
3-Year
ELEC-CKB-02-01Y
Circuit Breakers, Air, Low-Voltage Power
Oct-1
Annually
ELEC-CKB-02-03Y
Circuit Breakers, Air, Low-Voltage Power
Oct-1
3-Year
ELEC-CKB-03-01Y
Circuit Breakers, Air, Medium-Voltage
Oct-1
Annually
ELEC-CKB-03-03Y
Circuit Breakers, Air, Medium-Voltage
Oct-1
3-Year
ELEC-CKB-04-01M
Circuit Breakers, Oil, Medium- and High-Voltage
Oct-1
Monthly
ELEC-CKB-04-01Y
Circuit Breakers, Oil, Medium- and High-Voltage
Oct-1
Annually
ELEC-CKB-04-03Y
Circuit Breakers, Oil, Medium- and High-Voltage
Oct-1
3-Year
ELEC-CKB-05-01Y
Circuit Breakers, Vacuum, Medium-Voltage
Oct-1
Annually
ELEC-CKB-05-03Y
Circuit Breakers, Vacuum, Medium-Voltage
Oct-1
3-Year
ELEC-CLK-01-06M
Clocks, Central System
Oct-1
Semi-annually
ELEC-DCS-01-01M
DC Batteries, Lead Acid
Oct-1
Monthly
ELEC-DCS-01-01Y
DC, Batteries, Lead-Acid
Oct-1
Annually
ELEC-DCS-02-01M
Dry Cell Battery
Oct-1
Monthly
ELEC-DCS-03-03M
Nickel Cadmium Batteries
Oct-1
Quarterly
ELEC-DCS-04-01M
Direct-Current Systems, Chargers
Oct-1
Monthly
ELEC-DCS-04-01Y
Direct-Current Systems, Chargers
Oct-1
Annually
ELEC-EMG-01-01M
Emergency Generator, Electric Tests
Oct-1
Monthly
ELEC-EMG-01-01Y
Emergency Generator, Electric Tests
Oct-1
Annually
ELEC-GRD-01-01Y
Grounding Systems
Oct-1
Annually
ELEC-GRD-01-03Y
Grounding Systems
Oct-1
3-Year
ELEC-ITR-01-01Y
Instrument Transformers
Oct-1
Annually
ELEC-ITR-01-03Y
Instrument Transformers
Oct-1
3-Year
ELEC-LTG-01-03M
Dimmer and Control, Stage and General Lighting
Oct-1
Quarterly
ELEC-LTG-02-02Y
Fluorescent Lighting Fixture, Washing and Relamping
Oct-1
2-Year
ELEC-LTG-02-05Y
Fluorescent Light Fixture, Relamping Only
Oct-1
5-Year
ELEC-LTG-03-01Y
Lighting, Special Feature
Oct-1
Annually
ELEC-LTG-04-06M
Lighting, Outside Incandescent Fluorescent
Oct-1
Annually
ELEC-LTG-04-05Y
Lighting, Outside Incandescent Fluorescent, Mercury Vapor or High Pressure Sodium, Metal Halide
Oct-1
5-Year
ELEC-LTG-05-01M
Spotlights, Fixed and Portable
Oct-1
Monthly
ELEC-LTG-06-03M
Emergency Lights, Closed System
Oct-1
Quarterly
ELEC-LTG-07-03M
Emergency Lighting, Wet Cell
Oct-1
Quarterly
ELEC-MCC-01-01Y
Low-Voltage Motor Starters
Oct-1
Annually
ELEC-MCC-01-03Y
Low-Voltage Motor Starters
Oct-1
3-Year
ELEC-MCC-02-01Y
Medium-Voltage Motor Starters
Oct-1
Annually
ELEC-MCC-02-03Y
Medium-Voltage Motor Starters
Oct-1
3-Year
ELEC-MCC-03-01Y
Low-Voltage Motor Control Centers
Oct-1
Annually
ELEC-MCC-03-03Y
Low-Voltage Motor Control Centers
Oct-1
3-Year
ELEC-MCC-04-01Y
Medium-Voltage Motor Control Centers
Oct-1
Annually
ELEC-MCC-04-03Y
Medium-Voltage Motor Control Centers
Oct-1
3-Year
ELEC-MOT-01-01M
Rotating Machinery, AC Induction Motors and Generators
Oct-1
Monthly
ELEC-MOT-01-01Y
Rotating Machinery, AC Induction Motors and Generators
Oct-1
Annually
ELEC-MOT-01-02Y
Rotating Machinery, AC Induction Motors and Generators
Oct-1
2-Year
ELEC-MTR-01-01Y
Metering Devices
Oct-1
Annually
ELEC-MTR-01-03Y
Metering Devices
Oct-1
3-Year
ELEC-MTR-02-01Y
Advanced Metering
Oct-1
Annually
ELEC-NWP-01-01Y
Network Protectors, 600 V Class
Oct-1
Annually
ELEC-PVS-01-06M
Photovoltaic Systems
Oct-1
Annually
ELEC-REG-01-01M
Step-Voltage Regulators
Oct-1
Monthly
ELEC-REG-01-01Y
Step-Voltage Regulators
Oct-1
Annually
ELEC-REG-01-02Y
Step-Voltage Regulators
Oct-1
2-Year
ELEC-REG-02-01M
Induction Regulators
Oct-1
Monthly
ELEC-REG-02-01Y
Induction Regulators
Oct-1
Annually
ELEC-REG-02-03Y
Induction Regulators
Oct-1
3-Year
ELEC-REG-03-01M
Load-Tap-changers
Oct-1
Monthly
ELEC-REG-03-01Y
Load-Tap-changers
Oct-1
Monthly
ELEC-REG-03-03Y
Load-Tap-changers
Oct-1
3-Year
ELEC-RLY-01-01Y
Protective Relays, Microprocessor-Based
Oct-1
Annually
ELEC-SRG-01-01Y
Surge Arresters, Low-Voltage Surge Protection Devices
Oct-1
Annually
ELEC-SRG-01-03Y
Surge Arresters, Low-Voltage Surge Protection Devices
Oct-1
3-Year
ELEC-SRG-02-01Y
Medium Voltage Surge Arresters
Oct-1
Annually
ELEC-SRG-02-03Y
Medium Voltage Surge Arresters
Oct-1
3-Year
ELEC-SWB-01-01Y
Switchgear and Switchboard Assemblies
Oct-1
Annually
ELEC-SWB-01-03Y
Switchgear and Switchboard Assemblies
Oct-1
3-Year
ELEC-SWT-01-01Y
Low-Voltage Air Switches
Oct-1
Annually
ELEC-SWT-01-03Y
Low-Voltage Air Switches
Oct-1
3-Year
ELEC-SWT-02-01Y
Switches, Air, Medium-Voltage, Metal-Enclosed
Oct-1
Annually
ELEC-SWT-02-03Y
Switches, Air, Medium-Voltage, Metal-Enclosed
Oct-1
3-Year
ELEC-SWT-03-01Y
Medium- and High-Voltage Open Switches
Oct-1
Annually
ELEC-SWT-03-03Y
Medium- and High-Voltage Open Switches
Oct-1
3-Year
ELEC-SWT-04-01M
Medium-Voltage Oil Switches
Oct-1
Monthly
ELEC-SWT-04-01Y
Medium-Voltage Oil Switches
Oct-1
Annually
ELEC-SWT-04-03Y
Medium-Voltage Oil Switches
Oct-1
3-Year
ELEC-SWT-05-01Y
Medium-Voltage Vacuum Switches
Oct-1
Annually
ELEC-SWT-05-03Y
Medium-Voltage Vacuum Switches
Oct-1
3-Year
ELEC-SWT-06-01M
Medium-Voltage SF-6 Switches
Oct-1
Monthly
ELEC-SWT-06-01Y
Medium-Voltage SF6 Switches
Oct-1
Annually
ELEC-SWT-06-03Y
Medium-Voltage SF6 Switches
Oct-1
3-Year
ELEC-SWT-07-01Y
Cutouts
Oct-1
Annually
ELEC-SWT-07-03Y
Cutouts
Oct-1
3-Year
ELEC-TRN-01-01Y
Transformers, Dry-Type, Air-Cooled, Low-Voltage, Small
Oct-1
Annually
ELEC-TRN-01-03Y
Transformers, Dry-Type, Air-Cooled, Low-Voltage, Small
Oct-1
3-Year
ELEC-TRN-02-01Y
Transformers, Dry-Type, Air-Cooled, Large
Oct-1
Annually
ELEC-TRN-02-03Y
Transformers, Dry-Type, Air-Cooled, Large
Oct-1
3-Year
ELEC-TRN-03-01M
Transformers, Liquid-Filled
Oct-1
Monthly
ELEC-TRN-03-01Y
Transformers, Liquid-Filled
Oct-1
Annually
ELEC-TRN-03-03Y
Transformers, Liquid-Filled
Oct-1
3-Year
ELEC-UPS-01-01M
Uninterruptible Power System
Oct-1
Monthly
ELEC-UPS-01-01Y
Uninterruptible Power System
Oct-1
Annually
ELEC-VFD-01-01Y
Adjustable Speed Drive Systems
Oct-1
Annually
ELEC-VFD-01-03Y
Adjustable Speed Drive Systems
Oct-1
3-Year

FIRE LIFE SAFETY

FLSF-ALM-01-01M
Alarm Check Valves and Accessories
Oct-1
Monthly
FLSF-ALM-02-03M
Fire Supervisory Signals, Testing
Oct-1
Quarterly
FLSF-ALM-03-01Y
Automatic Fire Detection, Smoke Detectors
Oct-1
Annually
FLSF-ALM-04-03M
Automatic Fire Detection, Waterflow Alarms
Oct-1
Quarterly
FLSF-ALM-05-01Y
Automatic Fire Detection, Heat Detectors
Oct-1
Annually
FLSF-ALM-06-06M
Automatic Fire Detection, Operational Testing (per zone)
Oct-1
Semi-annually
FLSF-ALM-07-01Y
Fire Alarm Control Panel and Remote Annunciators
Oct-1
Annually
FLSF-ALM-08-01Y
Fire Alarm Control Panel, Special Systems (Halon, etc)
Oct-1
Annually
FLSF-ALM-09-01Y
Central Station, Transmitters
Oct-1
Annually
FLSF-ALM-10-01D
Central Station, Receiver and Re-transmission Equipment
Oct-1
Daily
FLSF-ALM-11-01W
Fire Alarm System, Recorder
Oct-1
Weekly
FLSF-ALM-12-03M
Fire Alarm System. Event Printer
Oct-1
Quarterly
FLSF-ALM-13-01Y
Fire Alarm System, Audio Control Panel
Oct-1
Annually
FLSF-ALM-14-01Y
Fire Alarm System, Remote Controller
Oct-1
Annually
FLSF-ALM-15-01Y
Fire Alarm System, Remote Amplifier
Oct-1
Annually
FLSF-ALM-16-01Y
Manual Fire Alarm Stations - Coded and Uncoded
Oct-1
Annually
FLSF-ALM-17-01Y
Fire Life Safety Fire Alarm
Oct-1
Annually
FLSF-ALM-17-05Y
Fire Life Safety Fire Alarm
Oct-1
5-Year
FLSF-DOR-01-03M
Fire Doors, Stairwells and Exitways, Swinging
Oct-1
Quarterly
FLSF-EPR-01-01Y
Emergency Generator; Gasoline, or Natural Gas Engine
Oct-1
Annually
FLSF-EPR-02-03M
Emergency Generator, Diesel Engines
Oct-1
Quarterly
FLSF-EPR-02-01Y
Emergency Generator, Diesel Engines
Oct-1
Annually
FLSF-EPR-03-01W
Emergency Generator
Oct-1
Weekly
FLSF-EPR-03-01M
Emergency Generator
Oct-1
Monthly
FLSF-EPR-03-03M
Emergency Generator
Oct-1
Quarterly
FLSF-EPR-03-06M
Emergency Generator
Oct-1
Semi-annually
FLSF-EPR-04-03M
Emergency Pumps and Ventilators
Oct-1
Quarterly
FLSF-EPR-04-01Y
Emergency Pumps and Ventilators
Oct-1
Annually
FLSF-EPR-05-06M
Fuel Oil Filter/Strainer
Oct-1
Semi-annually
FLSF-EPR-06-01Y
Fuel Oil Heater
Oct-1
Annually
FLSF-EPR-07-01M
Emergency Generator, Steam Driven
Oct-1
Monthly
FLSF-EPR-07-01Y
Emergency Generator, Steam Driven
Oct-1
Annually
FLSF-EPR-08-01Y
Load Bank Testing
Oct-1
Annually
FLSF-EPR-08-03Y
Load Bank Testing
Oct-1
3-Year
FLSF-FEX-01-01M
Fire Extinguisher, Inspection
Oct-1
Monthly
FLSF-FEX-01-05Y
Fire Extinguisher, Hydrostatic Testing
Oct-1
5-Year
FLSF-FEX-01-12Y
Fire Extinguisher, Hydrostatic Testing
Oct-1
12-Year
FLSF-FEX-02-01Y
Fire Extinguisher, Stored Pressure with Gauge
Oct-1
Annually
FLSF-FEX-02-06Y
Fire Extinguisher, Stored Pressure with Gauge (Non Stainless Steel Shell)
Oct-1
6-Year
FLSF-FEX-03-01Y
Fire Extinguishers - Non rechargeable
Oct-1
Annually
FLSF-FEX-04-01Y
Fire Extinguisher, Gas Cartridge or Cylinder (No Gauge)
Oct-1
Annually
FLSF-FEX-05-01M
Water Spray Extinguishing Systems
Oct-1
Monthly
FLSF-FEX-05-01Y
Water Spray Extinguishing Systems
Oct-1
Annually
FLSF-FEX-06-01M
Fire Extinguisher System, Carbon Dioxide (High Pressure), Halon, Dry Chemical - Inspection
Oct-1
Monthly
FLSF-FEX-06-06M
Fire Extinguisher System, Carbon Dioxide (High Pressure), Halon, Dry Chemical
Oct-1
Semi-annually
FLSF-FSD-01-02Y
Fire and Smoke Dampers
Oct-1
2-Year
FLSF-FSP-01-01Y
Sprinkler Head, Sprinklered Areas (per 1,000 sq. ft.)
Oct-1
Annually
FLSF-FSP-02-01Y
Antifreeze Solution in Sprinkler Systems
Oct-1
Annually
FLSF-HSE-01-01M
Fire Hose - 1.5 in., Racked in Buildings
Oct-1
Monthly
FLSF-HSE-01-01Y
Fire Hose - 1.5 in., Racked in Buildings
Oct-1
Annually
FLSF-HSE-02-03M
Fire Department Hose Connections (Standpipe Outlets)
Oct-1
Quarterly
FLSF-HSE-02-05Y
Fire Department Hose Connections (Standpipe Outlets)
Oct-1
5-Year
FLSF-HSE-03-01M
Fire Department Pumper Connections, Standpipe or Sprinkler
Oct-1
Monthly
FLSF-HYD-01-05Y
Fire Hydrant Flow Test - Dry Barrel and Wet Barrel
Oct-1
5-Year

FLSF-HYD-01-06M

FLSF-PMP-01-01W
Fire Pump, Diesel Engine Driven
Oct-1
Weekly
FLSF-PMP-01-01M
Fire Pump, Diesel Engine Driven
Oct-1
Monthly
FLSF-PMP-01-03M
Fire Pump, Diesel Engine Driven
Oct-1
Quarterly
FLSF-PMP-01-01Y
Fire Pump - Diesel Engine Driven
Oct-1
Annually
FLSF-PMP-02-01W
Fire Pump - Electric Motor Driven
Oct-1
Weekly
FLSF-PMP-02-01M
Fire Pump - Electric Motor Driven
Oct-1
Monthly
FLSF-PMP-02-01Y
Fire Pump - Electric Motor Driven
Oct-1
Annually
FLSF-VLV-01-01W
Dry Pipe, Deluge and Preaction Valves
Oct-1
Weekly
FLSF-VLV-01-01M
Dry Pipe, Deluge and Preaction Valves
Oct-1
Monthly
FLSF-VLV-01-01Y
Dry Pipe, Deluge and Preaction Valves
Oct-1
Annually
FLSF-VLV-01-05Y
Dry Pipe, Deluge and Preaction Valves: Strainers, Filters and Orifices
Oct-1
5-Year
FLSF-VLV-02-01M
Post Indicator Valves
Oct-1
Annually
FLSF-VLV-03-01W
Fire Control Valves
Oct-1
Weekly
FLSF-VLV-03-01M
Fire Control Valves
Oct-1
Monthly
FLSF-VLV-03-01Y
Fire Control Valves
Oct-1
Annually
FLSF-VLV-04-01Y
Valves, Fire System - Pressure Regulating Type
Oct-1
Annually
FLSF-VLV-04-05Y
Valves, Fire System - Pressure Regulating Type
Oct-1
5-Year

HEATING VENTILATION AND AIR CONDITIONING

HVAC-ACR-01-01M
Air Conditioning Unit, Special Purpose
Oct-1
Monthly
HVAC-ACR-02-01Y
Heat Pumps, Water Cooled
Oct-1
Annually
HVAC-ACR-03-01Y
Air Conditioning Unit or Heat Pump, Split System
Oct-1
Annually
HVAC-ACR-04-01Y
Air Conditioning Unit, Ceiling/Wall Mounted
Oct-1
Annually
HVAC-ACR-05-01Y
Air-cooled Condenser
Oct-1
Annually
HVAC-ACR-06-01Y
Evaporative Condenser
Oct-1
Annually
HVAC-AHU-01-02M
Built Up Air Handler, Predictive Maintenance
Oct-1
Bi-Monthly
HVAC-AHU-01-01Y:
Built-Up AHU
Oct-1
Annually
HVAC-AHU-03-01Y
Built-Up AHU >5000 CFM Predictive
Oct-1
Annually
HVAC-AHU-04-01Y
Package AHU (includes DX, Heat Pumps, Gas Heat)
Oct-1
Annually
HVAC-AHU-05-01Y
Package AHU Predictive
Oct-1
Annually
HVAC-AHU-06-01Y
Air Washer or Wet Coil System
Oct-1
Annually
HVAC-AHU-07-01Y
Hot Air Furnace
Oct-1
Annually
HVAC-AHU-08-01Y
AHU UV Treatment System
Oct-1
Annually
HVAC-AIR-01-06M
Air Dryer, Refrigerated or Regenerative Desiccant Type
Oct-1
Annually
HVAC-AIR-02-06M
Air Compressor
Oct-1
Semi-annually
HVAC-AIR-03-06M
Glycol Dry Cooler
Oct-1
Semi-annually
HVAC-AIR-04-06M
After-Cooler/Separator
Oct-1
Semi-annually
HVAC-BLR-01-01Y
Boiler (Natural Gas and Oil Fired)
Oct-1
Annually
HVAC-BLR-02-01Y
Boiler, Electric
Oct-1
Annually
HVAC-BLR-03-01Y
Burner, Gas
Oct-1
Annually
HVAC-BLR-04-01Y
Burner, Oil
Oct-1
Annually
HVAC-BLR-05-01Y
Boiler, Instruments/Controls
Oct-1
Annually
HVAC-BSB-01-02Y
Radiant Baseboards/Convectors (steam, hot water, or electric - per linear foot)
Oct-1
2-Year
HVAC-CLR-01-03M
Central Chilled Water Package Unit, Special Purpose
Oct-1
Quarterly
HVAC-CLR-01-01Y
Central Chilled Water Package Unit
Oct-1
Annually
HVAC-CLR-02-01Y
Refrigeration Machine, Screw and Scroll
Oct-1
Annually
HVAC-CLR-03-01Y
Refrigeration Machine, Centrifugal
Oct-1
Annually
HVAC-CLR-04-01Y
Refrigeration Machine, Absorption Unit
Oct-1
Annually
HVAC-CLR-05-01Y
Control Panel - Central Refrigeration Unit
Oct-1
Annually
HVAC-CLR-06-01M
Refrigerant Monitor
Oct-1
Monthly
HVAC-CLR-07-01Y
High Efficiency Purge Units
Oct-1
Annually
HVAC-CLR-08-02Y
Vibration Analysis, Chillers
Oct-1
2-Year
HVAC-CLR-09-03Y
Non-Destructive Tube Analysis (Eddy Current Analysis)
Oct-1
3-Year
HVAC-CLS-01-01Y
Coils, Preheat, Reheat, Etc. (Remote Locations)
Oct-1
Annually
HVAC-CND-01-01M
Condensing Unit, Refrigeration
Oct-1
Monthly
HVAC-CND-01-01Y
Condensing Unit, Refrigeration
Oct-1
Annually
HVAC-DMP-01-01Y
Motorized Dampers, Pneumatic or Electric
Oct-1
Annually
HVAC-EVP-01- 03M
Indirect Evaporative Cooling
Oct-1
Quarterly
HVAC-EVP-02-03M
Direct Evaporative Cooling
Oct-1
Quarterly
HVAC-EVP-03-03M
Humidification Systems
Oct-1
Quarterly
HVAC-FAN-01-01Y
Fan, Centrifugal
Oct-1
Annually
HVAC-FAN-02-01Y
Fan, Propeller, 24 in. Diameter or Larger
Oct-1
Annually
HVAC-FCU-01-03M
Fan Coil Units
Oct-1
Quarterly
HVAC-FLT-01-03M
Filter, Throw Away
Oct-1
Quarterly
HVAC-FLT-02-03M
Filter, Roll Type, Disposable Media
Oct-1
Quarterly
HVAC-FLT-02-01Y
Filter, Roll Type, Disposable Media, Manual or Motor Driven
Oct-1
Annually
HVAC-FLT-03-03M
Filter, Electrostatic
Oct-1
Quarterly
HVAC-FLT-04-03M
Filters, Viscous Type (Wire Mesh)
Oct-1
Quarterly
HVAC-FLT-05-03M
Filter, Charcoal
Oct-1
Quarterly
HVAC-FLT-06-01M
Filter, Special situations or conditions
Oct-1
Monthly
HVAC-HXR-01-01Y
Plate and Frame Heat Exchanger
Oct-1
Annually
HVAC-PMP-01-01Y
Pump, Centrifugal
Oct-1
Annually
HVAC-PMP-02-01Y
Pump, Vacuum
Oct-1
Annually
HVAC-STM-01-01Y
Condensate or Vacuum Pump
Oct-1
Annually
HVAC-TAB-01-05Y
Test and Balance
Oct-1
5-Year
HVAC-TMU-01-01Y
Terminal Units, Pneumatic or Electric
Oct-1
Annually
HVAC-TMU-02-03M
Terminal Units, DDC Only, Predictive
Oct-1
Quarterly
HVAC-TWR-01-03M
Cooling Tower, Cleaning
Oct-1
Quarterly
HVAC-TWR-01-01Y
Cooling Tower, Maintenance
Oct-1
Annually
HVAC-UHT-01-01Y
Unit Heater (Steam and Hot Water)
Oct-1
Annually
HVAC-UHT-02-01Y
Unit Heater (Gas and Oil Fired)
Oct-1
Annually
HVAC-VLV-01-01Y
Valve, Motor Operated (DDC)
Oct-1
Annually
HVAC-WTM-01-01M
Water Treatment Guide
Oct-1
Monthly
HVAC-WTM-03-06M
Chemical Feeder
Oct-1
Semi-annually
HVAC-WTM-04-03M
Water Treatment, Chemical Free
Oct-1
Quarterly
HVAC-WTM-04-01Y
Water Treatment, Chemical Free
Apr-12
Annually

KITCHEN

KTCH-DSH-01-03M
Dishwashing Machine
Oct-1
Quarterly
KTCH-FRY-01-03M
Fryer
Oct-1
Quarterly
KTCH-GRL-01-03M
Grill
Oct-1
Quarterly
KTCH-ICM-01-03M
Ice Cream & Shake Maker
Oct-1
Quarterly
KTCH-ICE-02-03M
Ice Maker
Oct-1
Semi-annually
KTCH-KTL-01-06M
Kettle
Oct-1
Semi-annually
KTCH-OVN-01-03M
Oven
Oct-1
Quarterly
KTCH-OVN-01-06M
Oven
Oct-1
Semi-annually
KTCH-RFG-01-03M
Walk-In Refrigerators and Freezers
Oct-1
Quarterly
KTCH-RFG-01-06M
Walk-In Refrigerators and Freezers
Oct-1
Semi-annually
KTCH-RFG-02-03M
Reach-In Refrigerators and Freezers
Oct-1
Quarterly
KTCH-RFG-02-06M
Reach-In Refrigerators and Freezers
Oct-1
Semi-annually
KTCH-RNG-01-03M
Range
Oct-1
Quarterly
KTCH-RNG-01-06M
Range
Oct-1
Semi-annually

MATERIAL HANDLING

MHDL-CRN-01-03M
Crane, Electric
Oct-1
Quarterly
MHDL-DMW-01-03M
Dumbwaiter
Oct-1
Quarterly
MHDL-HST-01-01Y
Chain Hoist and Trolley
Oct-1
Annually
MHDL-HST-02-01Y
Hoist, Electric
Oct-1
Annually
MHDL-HST-03-01Y
Hoist, Lighting
Oct-1
Annually
MHDL-LFT-01-06M
Lift, Electric, Stage Screen
Oct-1
Semi-annually
MHDL-LFT-02-01M
Material Handling Equipment Electric Lift Trucks
Oct-1
Monthly
MHDL-LFT-02-01Y
Material Handling Equipment Electric Lift Trucks
Oct-1
Annually
MHDL-LFT-03-03M
Loading Ramp, Adjustable
Oct-1
Quarterly
MHDL-LFT-04-01M
Lift, Automotive
Oct-1
Monthly
MHDL-LFT-04-01Y
Lift, Automotive
Oct-1
Annually
MHDL-PPB-01-01Y
Paper Baler
Oct-1
Annually
MDHL-VHL-01-06M
Material Handling Equipment, Engine Driven Vehicles
Oct-1
Semi-annually
MHDL-VHL-02-01Y
Carts and Scooters, Engine or Battery Powered
Oct-1
Annually

PLUMBING

PLMB-DRN-01-01Y
Roof Drains, Downspout, and Gutter Inspection
Oct-1
Annually
PLMB-DRN-02-01Y
Drains, Areaway, Driveway, Storm
Oct-1
Annually
PLMB-DWS-01-01Y
Hot Water Heater, Gas
Oct-1
Annually
PLMB-DWS-02-01Y
Hot Water Heater, Electric
Oct-1
Annually
PLMB-DWS-03-01Y
Hot Water Heater, Steam Coil
Oct-1
Annually
PLMB-DWS-04-06M
Water Softener
Oct-1
Semi-annually
PLMB-DWS-05-06M
Water Filter
Oct-1
Semi-annually
PLMB-DWV-01-01Y
Sewage Ejector (Pneumatic Tank Type Ejectors)
Oct-1
Annually
PLMB-DWV-02-01Y
Sewage ejector, Sump Type
Oct-1
Annually
PLMB-DWV-03-01Y
Sump Pump
Oct-1
Annually
PLMB-DWV-04-01W
Emergency Wash
Oct-1
Weekly
PLMB-DWV-05-01Y
Emergency Shower
Oct-1
Annually
PLMB-DWV-06-01Y
Septic Tank and Drain Field
Oct-1
Annually
PLMB-HWS-01-01Y
Hot Water Converter, Steam
Oct-1
Annually
PLMB-HWS-02-06M
Solar Heating System
Oct-1
Semi-annually
PLMB-HWS-02-01Y
Solar Heating System
Oct-1
Annually
PLMB-PLB-01-01Y
Expansion Joints in Piping
Oct-1
Annually
PLMB-PLB-02-01Y
Strainer, Y-Type
Oct-1
Annually
PLMB-PLB-03-01Y
Strainer, Bolted Flange (water and steam)
Oct-1
Annually
PLMB-PLB-04-01Y
Dual Strainer
Oct-1
Annually
PLMB-PLB-05-01Y
Backwash Strainer
Oct-1
Annually
PLMB-PLB-06-01Y
Steam Traps, All Types high pressure
Oct-1
Annually
PLMB-PLB-06-05Y
Steam Traps, All Types low pressure
Oct-1
5-Year
PLMB-PLB-07-01Y
Distiller, Water, Laboratory use only
Oct-1
Annually
PLMB-VLV-01-01M
Valve, Safety Relief
Oct-1
Monthly
PLMB-VLV-02-01Y
Valve Regulating
Oct-1
Annually
PLMB-VLV-03-01Y
Valve, Manually Operated
Oct-1
Annually
PLMB-VLV-04-01Y
Valve, Critical Check
Oct-1
Annually
PLMB-VLV-05-01Y
Backflow Preventer
Oct-1
Annually

TANKS

TANK-AGS-01-01Y
Tank, Air/Refrigerant/LP Gas
Oct-1
Annually
TANK-CHM-01-01Y
Tank, Chemical
Oct-1
Annually
TANK-FOL-01-04Y
Tank, Fuel Oil Storage
Oct-1
4-Year
TANK-UST-01-01M
Underground Storage Tank (UST)
Oct-1
Anually
TANK-WTR-01-03Y
Tank, Water (All Types)
Oct-1
3-Year

VERTICAL TRANSPORTATION

VTRN-ELV-01-06M
Elevator, Hydraulic, Inspection 4 floors or less.
Oct-1
Semi-annually
VTRN-ELV-01-01Y:
Elevator, Hydraulic, Inspection 4 floors or less.
Oct-1
Annually

VTRN-ELV-02-06M

VTRN-ELV-02-01Y
Elevator, Electric, Inspection 4 floors or less.
Oct-1
Annually
VTRN-ELV-02-05Y
Elevator, Electric, Inspection 4 floors or less.
Oct-1
5-Year
VTRN-ELV-03-01W
Elevator, Electric or Hydraulic 4 floors or less.
Oct-1
Weekly
VTRN-ELV-03-01M
Elevator, Electric or Hydraulic 4 floors or less.
Oct-1
Monthly
VTRN-ELV-03-03M
Elevator, Electric or Hydraulic
Oct-1
Quarterly
VTRN-ESC-01-01W
Escalator
Oct-1
Weekly
VTRN-ESC-01-01Y
Escalator (and Moving Walkway)
Oct-1
Annually
VTRN-WLF-01-01M
Wheelchair Lift
Oct-1
Monthly

Section 2: Preventative Maintenance Standards

ARCS-BAR-01-06M
Frequency: Semi-annually

Security Bollards/Barricade

Application:

This standard card applies to automatic hydraulic security Bollards/Barricades found at driveway entrances, and other areas where vehicular traffic must be controlled.

Special Instructions:

69. Preventive maintenance services should be performed by a qualified manufacturer's service representative.

70. Review manufacturer's instructions.

71. Review the Standard Operating Procedure for "Controlling Hazardous Energy Sources".

72. De-energize, lock out, and tag electrical circuits.

73. This work should be scheduled at non-peak hours.

74. Notify affected personnel before performing PM (alarmed or security entrances).

75. Post "out of service" signs and/or barricades, as appropriate.

Check points:

76. Check that Bollards/Barricade extend to full height.

77. Check that Bollards/Barricade retract to full depth.

78. Check Bollards/Barricade for exterior damage.

79. Check and clean sump pits and pump.

80. Check that Bollards/Barricade fasteners are tight.

81. Check Bollard/Barricade safeties (proximity, Photo, infra red, pressure etc)

82. Check Bollard/Barricade activation devices for proper operation (auto/manual/emergency)

83. Check Bollard operation under no power.

84. Inspect electrical power panel. Check electrical connections and wiring for loose or overheated conditions.

85. Inspect control panel for loose connections.

86. Check that traffic light functions, change lamps and clean lenses every 12 months.

87. Check hydraulic unit fluid level and pressures/ change fluid per manufactures recommendations.

88. Check hydraulic unit fluid connections, pump, piping and hoses for damage and leaks.

89. Clean motor and assembly.

90. Check the drive motor amperage against nameplate.

91. Clean drive mechanism compartment.

92. Inspect Bollard/Barricade coatings, decals and paint.

93. Check that all placards and warnings signs are posted.

Recommended Tools, Materials, and Equipment:

94. Tool Group A

ARCS-DAV-01-01Y
Frequency: Annually

Davits

This standard applies to davits, structures typically used to lower things over an edge. This standard is not intended to address all fall protection related equipment.

Special Instructions:

95. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered.

96. All fall protection equipment is required by OSHA to be checked prior to each use.

97. This section does not address powered man-lifts, harnesses, self retracting fall limiters, shock absorbers, and other related fall protection equipment that falls into the above requirements.

98. Any and all personnel involved in the use or maintenance of fall protection or who may, in the course of their work, be present on any elevated surface without a guard rail are required to have regular training in fall protection safety. Conformance includes but is not limited to ASME, ASME A 120.1, IWCA I 14.1, OSHA 1910.66, CALOSHA, AISC, AWS and local code requirements.

99. Visually inspect for corrosion. Verify all components are securely mounted.

100. Check bolt torque.

Check Points:

See Special Instructions.

Recommended Tools, Materials, and Equipment:

101. Standard Tools – Basic.

ARCS-DOR-01-06M
Frequency: Semi-annually

Door, Power Operated

This standard applies to warehouse or large overhead rolling doors.

Special Instructions:

102. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered.

103. Review manufacturer’s instructions.

104. Follow lock out/tag out procedures at all times. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work.

Check Points:

105. Inspect general arrangement of door and mechanism, mountings, standards, wind locks, anchor bolts, counterbalances, weather stripping, door sweeps etc. Clean, tighten, and adjust repair as required.

106. Operate with power from stop to stop and at intermediate positions. Observe performance of various components, such as brake, limit switches, door operating speed, motor, gear box, etc. Clean and adjust as needed.

107. Check operation of safety edges, stops, electric eye, treadle, or other operating devices. Clean and make required adjustments or repairs.

108. Check manual operation. Note brake release, motor disengagement, functioning or hand pulls, chains sprockets, clutch, etc.

109. Examine all wiring, motor, starter, push button, etc., blow out or vacuum if needed.

110. Inspect gear box, change or add oil as required.

111. Perform required lubrication. Remove old or excess lubricant.

112. Clean unit and mechanism thoroughly. Touch up paint where required.

113. Clean up and remove all debris.

Recommended Tools, Materials, and Equipment:

114. Standard Tools-Basic

115. Lubricants. Consult the Material Safety Data Sheets (MSDS) for hazardous ingredients and proper personal protective equipment (PPE).

116. Cleaning Materials. Consult the MSDS for hazardous ingredients and proper PPE.

ARCS-DOR-02-03M
Frequency: Quarterly

Door; Hydraulic, Electric or Pneumatic Operated

Application This standard applies to entrance doors operated by sensors or switches (i.e. handicap access doors).

Special Instructions:

117. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered to.

118. Set suitable barriers at the entrance and exit of the door. Prevent obstructions from impeding pedestrian traffic around the work area.

119. Follow lock out/tag out procedures at all times. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work.

Check Points:

120. Check alignment of door and mechanism. Inspect mountings, hinges, mats, and trim, weather stripping, etc. Replace, tighten, and adjust as required.

121. Operate with power, observing operation of actuating and safety mats, door speed, and checking functions.

122. Check manual operation.

123. Inspect power unit, lubricate and tighten lines as required.

124. Check operation of control board relays, clean, replace, adjust contacts as required.

125. Inspect door operating unit, tighten lines, and adjust as required.

126. Clean and lubricate door pivot points.

127. On pneumatic or hydraulically operated door operators, check for correct operating pressures per manufacturer’s instructions.

128. Clean up and remove all debris from work area.

Recommended Tools, Materials, and Equipment:

129. Tool Group B

130. Lubricants. Consult the Material Safety Data Sheets (MSDS) for hazardous ingredients and proper personal protective equipment (PPE).

ARCS-DOR-03-06M
Frequency: Semi-annually

Door, Manual, Overhead

131. This standard applies to manually operated overhead doors. These doors normally range in size from 7 to 24 feet wide by 7 to 20 feet in height.

Special Instructions:

132. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered to.

133. If the door is equipped with intrusion alarms, notify the appropriate person before operating.

134. Schedule maintenance on these doors so that it does not interfere with loading dock operations.

135. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work. Follow lock out/tag out procedures at all times.

Check Points:

136. Inspect general arrangement of door and mechanism, mountings, standards, wind locks, anchor bolts, counterbalance, weather-stripping, etc. Clean, tighten, and adjust as required. Make minor repairs as needed.

137. Inspect cables for frayed or broken strands or excessive rusting.

138. Inspect winding drum for tightness and proper tracking of cables.

139. Manually raise and lower door, noting that door tracks evenly and action of break release, functioning of hand pulls, chains, sprockets, clutch, etc.

140. If equipped, inspect gearbox; change or add oil as needed.

141. Perform required lubrication. Remove old or excess lubricant.

142. Clean unit and mechanism thoroughly. Touch up paint where needed.

Recommended Tools, Materials, and Equipment:

143. Standard tools – basic

144. Rust inhibitor and paint. Consult the Material Safety Data Sheets (MSDS) for hazardous ingredients and proper personal protective equipment (PPE).

145. Grease gun, oil, and grease

146. Ladder constructed according to OSHA/ANSI standards. Check ladder for defects. Do not use defective ladders.

ARCS-DOR-04-06M
Frequency: Semi-annually

Door, Manually Operated Entrance

This standard applies to manually operated entrance doors, hinged and sliding type.

Special Instructions:

147. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered to.

148. Set suitable barriers at the entrance and exit of the door. Prevent obstructions from impeding pedestrian traffic around the work area.

149. Follow lock out/tag out procedures at all times. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work.

Check Points:

150. Hinged Doors

Inspect the frame and supporting structures.

Inspect hardware; hinges, latch keeper, lock, etc. Apply graphite where needed, wipe off excess.

Inspect glass, putty, or retaining pieces. Correct any deficiencies.

Operate door to observe functioning of check. Adjust and service as needed.

Check opening/closing resistance pressure and speed.

Touch up paint as needed.

Clean up and remove all debris from work area.

151. Sliding Doors

Center door within track and remove, start by lifting up to remove from bottom track first.

Clean out track of any debris.

Inspect hardware; rollers, track etc. Correct any deficiencies.

Return door to track, start by inserting door into bottom track first.

Operate door to observe function.

Check opening/closing resistance pressure and speed.

Touch up paint as required.

Clean up and remove all debris from work area.

152. Revolving Doors

Remove obstructions and clean out track.

Fold door. Note action and freedom of motion.

Inspect locking device, adjust as needed.

Clean pivot points and apply graphite.

Inspect felt or rubber seals.

Set the emergency fold pressure on the door to the manufacturer’s specifications.

Touch up paint as required.

Clean up all debris from work area.

Recommended Tools, Materials, and Equipment:

153. Standard Tools - Basic.

154. Graphite. Consult the Material Safety Data Sheets (MSDS) for hazardous ingredients and proper personal protective equipment (PPE).

155. Clean wiping cloths.

156. Suitable barriers.

ARCS-FPL-01-01M
Frequency: Monthly

Fireplace

The purpose of this standard is to perform a cleaning of the fire box and an inspection of the flue, chimney, fire damper, and smoke shelf. This function should be performed once a month, during the time of year that the fireplace is in use.

Special Instructions:

157. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered to.

158. Review manufacturer's instructions.

159. Schedule shutdown with operating personnel.

160. Follow lock out/tag out procedures at all times. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work.

161. Do not use any flammable lubricants or solvents. If lubrication is necessary, use only dry powdered graphite.

Check Points:

1. Remove loose ash and vacuum inside of fire box (fireplace).

2. Inspect fire brick and mortar joints for cracks or breakage. Repair or replace as necessary.

3. Inspect fire damper, checking for proper operation.

4. Make a visual inspection of the flue and chimney, checking for obstructions.

5. Clean surrounding area.

Recommended Tools, Materials, and Equipment:

1. Standard tools - basic

2. Small shovel, dust pan, and broom

3. Vacuum

4. Eye protection, NIOSH/MSHA approved respirator, gloves, and coveralls

ARCS-FPL-02-01Y
Frequency: Annually

Incinerator

The work required by this standard applies to incinerators.

Special Instructions:

1. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered to.

2. Review manufacturer's instructions.

3. Schedule shutdown with operating personnel.

4. Follow lock out/tag out procedures at all times. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work.

5. If the insulation is known or suspected to contain asbestos, check the building's asbestos management plan to see it has been tested for asbestos. If it is suspect but has not been tested, have it tested. Manage asbestos in accordance with the plan.

Check Points:

1. Thoroughly clean furnace, ash pit, grates, etc.

2. Remove fly ash and soot from flue gas passages.

3. Examine furnace. Replace burned or damaged parts.

4. Inspect for loose, broken, or missing refractory or fire brick.

5. Examine all doors, inspect and/or clean out ports. Make them fit properly and stop any air leaks around them.

6. Check uptakes or connections to stack or chimney. Remove dirt, fly ash scale, etc.

7. Examine dampers for condition and freedom of motion.

8. Examine structure and supports. Look for warped or sagging members, cracks, or other indications of weakness.

9. Check charging chute, frame, cover, etc. Replace broken, missing, or defective parts.

10. Check all instruments, gauges, etc. Test for proper operation.

11. Repair any damaged or missing insulation. If the insulation contains asbestos, refer to Appendix G for the Universal Waste Guide.

12. Inspect stack or chimney for holes, cracks or deterioration.

13. Inspect spark arrestor or screen on top of stack. Repair holes as necessary or replace.

14. Clean up work area and remove all debris.

Recommended Tools, Materials, and Equipment:

1. Standard Tools - Basic

2. Respirator

3. Goggles

4. Cleaning equipment and materials. Consult the Material Safety Data Sheets (MSDS) for hazardous ingredients and proper personal protective equipment (PPE).

ARCS-LND-01-06M
Frequency: Semi-annually

Fountain, Memorial or Decorative

The work required by this standard applies to memorial or decorative fountains. These fountains normally operate during the summer season. They are usually drained and secured in the fall and are reactivated again in the spring.

Special Instructions:

1. In addition to the procedure(s) outlined in this standard, the equipment manufacturer’s recommended maintenance procedure(s) and/or instruction(s) shall be strictly adhered to.

2. Review manufacturer's instructions.

3. Schedule shutdown with operating personnel.

4. Follow lock out/tag out procedures at all times. De-energize or discharge all hydraulic, electrical, mechanical, or thermal energy prior to beginning work.

Check Points:

Fall

1. Drain fountain

2. Remove fountain head(s)

3. Clean scale from head(s) after removing and install cover plate.

4. Clean bolts and spacers. Replace defective bolts as needed.

5. Check and clean fill tube, remove spacer pipe and cap fill tube.

6. Clean overflows and strainers.

7. Check for structural damage. Repair as necessary.

8. Where…