Drawings.pdf
PDF 16 MB Posted
- Attached to
- Stokes Hardening Project Federal contract opportunity
- Solicitation number
- 47PF0025R0015
About this file
The file is a comprehensive set of architectural and security drawings for the Stokes Hardening Project at the Carl B. Stokes U.S. Courthouse in Cleveland, Ohio. The drawings detail the interior renovation and security enhancement of ground-level windows and entry points, specifically focusing on installing new security glazing storefronts, replacing exterior doors, and upgrading rotunda entry doors to provide forced-entry resistance. The technical specifications include detailed requirements for door and window installations, using Riot Glass Armorplast Gen II security framing with AP375BR glazing panels, adhering to ASTM F3038-21 standards for 15-minute forced-entry protection.
The drawings specify critical security and technical requirements, including door hardware integration with fire alarm systems, fail-secure door operations, and compliance with accessibility standards like the Architectural Barriers Act Accessibility Standard (ABAAS). Specific technical details include steel frame specifications (6" x 1/2" A500 Grade B), custom field-applied finishes, and precise installation methodologies for anchoring and mounting. The project involves protecting existing limestone facades, coordinating with US Marshals, and maintaining continuous building operations during construction, with a performance period of 173 calendar days and an estimated construction cost between $1,000,000 and $2,000,000.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 0003_Amendment.pdf | ||
| 0001-Amendment.pdf | ||
| Request for Information Responses.pdf | ||
| 0002_Extension.pdf | ||
| Attendance Sheet_ 031125.pdf | ||
| Pre Bid Conference_031125.pdf | ||
| SF24-23a.pdf | ||
| RFP 47PF0025R0015.pdf | ||
| WD OH20250074_010325.pdf | ||
| Form_SF1442.pdf | ||
| Specifications.pdf | ||
| Form_SF24.pdf | ||
| Form_GSA527.pdf | ||
| Past Performance Sheet.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G001
SFS
LH
GENERAL
COVER
G002
LH
1ST
GENERAL
KEY PLAN
1. THE BUILDOUT DESCRIBED IN THESE DOCUMENTS IS INTENDED TO UTILIZE THE BUILDING'S STANDARD TENANT IMPROVEMENT SYSTEMS, MATERIALS, AND
FINISHES, UNLESS OTHER SPECIFIC REQUIREMENTS ARE INDICATED.
2. THESE DRAWINGS MAY NOT ACCURATELY REPRESENT THE EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL SURVEY THE EXISTING FIELD CONDITIONS IN DETAIL TO BECOME FAMILIAR WITH ANY ITEM THAT MAY AFFECT THE CONSTRUCTION. SUCH CONDITIONS INCLUDE, BUT ARE NOT LIMITED TO THE EXACT LOCATION AND CONDITION OF ALL PARTITIONS, DOORS, FRAMES, HARDWARE, GLASS, MILLWORK, CEILINGS, FINISHES, ELECTRICAL AND COMMUNICATION DEVICES, PLUMBING FIXTURES, FIRE SPRINKLERS, FIRE ALARM DEVICES, ETC. ALSO INSPECT CONDITIONS ABOVE THE CEILING, INCLUDING DUCTWORK AND DIFFUSERS, MECHANICAL DEVICES, SPRINKLER PIPING, AND ANY OTHER OBJECT THAT COULD BE AN OBSTRUCTION TO THE INDICATED
DESIGN. NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCY IDENTIFIED.
3. THESE DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE PROJECT REQUIREMENTS. DO NOT SCALE THE DRAWINGS FOR DIMENSIONS. VERIFY ALL
SHOWN DIMENSIONS. FIELD MEASURE FOR DIMENSIONS NOT SHOWN.
4. EACH SUBCONTRACTOR SHALL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED TO COMPLETE CONTRACTED WORK, INCLUDING RIGGING OF MATERIALS AND EQUIPMENT, ALL HANGERS, SUPPORTS, ANCHORS, SUSPENSION MEANS, CONDUIT, WIRE, FITTINGS AND/OR SLEEVES.
5. IN THE EVENT OF CONFLICT BETWEEN INFORMATION SHOWN ON DRAWINGS AND INFORMATION SHOWN ON THE SPECIFICATIONS, THE MORE STRINGENT SHALL TAKE PRECEDENCE. SHOULD THE CONTRACTOR AT ANY TIME DISCOVER AN ERROR IN A DRAWING OR SPECIFICATION OR A DISCREPANCY OR VARIATION BETWEEN DIMENSIONS ON DRAWINGS AND MEASUREMENTS AT THE SITE OR LACK OF DIMENSIONS OR OTHER INFORMATION, THE GENERAL CONTRACTOR SHALL NOT PROCEED WITH THE WORK AFFECTED UNTIL THE ARCHITECT HAS BEEN NOTIFIED AND PROCEED ONLY AFTER CLARIFICATION HAS
BEEN MADE
6. IT IS INTENDED THAT THE DESIGN AS INDICATED ON THESE DRAWINGS AND AS DEVELOPED BY THE ARCHITECT AND ENGINEER OF RECORD SHALL COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS. THE CURRENT EDITION OF EACH APPLICABLE CODE AT THE TIME OF DESIGN
CONTRACT AWARD SHALL APPLY.
· FOLLOW THE NATIONALLY RECOGNIZED MODEL BUILDING CODES: INTERNATIONAL BUILDING CODE (IBC 2021);
· THE ELECTRICAL REQUIREMENTS OF THE NFPA NATIONAL ELECTRICAL CODE;
· THE EGRESS REQUIREMENTS OF THE NFPA LIFE SAFETY CODE (NFPA 101);
· THE REQUIREMENTS OF THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS), MOST CURRENT EDITION. WHERE EVER THE
TERMINOLOGY (ABA) OCCURS IN THIS SET REFERENCE IS MADE TO THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD.
· THE FACILITY STANDARDS FOR THE PUBLIC BUILDING SERVICE (PBS-P100, 2022);
7. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. THE CONTRACTOR SHALL CONTACT THE GSA CONTRACTING OFFICER IF DISCREPANCIES ARE DISCOVERED, PRIOR TO PROCEEDING WITH DEMOLITION AND CONSTRUCTION WORK.
8. THE GOVERNMENT REQUIRES THAT ALL DESIGN MODIFICATIONS MEET A MINIMUM 15-MINUTE FORCED-ENTRY RESISTANCE IN ACCORDANCE WITH ASTM
STANDARD
9. ALL DOORS TO HAVE PANIC BAR HARDWARE THAT IS INTEGRATED INTO FIRE ALARM SYSTEM. DOOR HARDWARE WILL RELEASE UPON ACTIVATION. GUARD REMOTE ACTIVATION BUTTON WILL ACTIVATE AND ENGAGE DOOR HARDWARE LOCKS. DOORS TO OPERATE AS FAIL SECURE, DOORS TO MEET NFPA 101
EGRESS REQUIREMENTS AND BE FREE EGRESS AT ALL TIMES.
GENERAL NOTES
0 60'30'15' 1" = 30'-0"
5'
PROJECT LIMIT - LINE OF PROTECTION KEY PLAN1
G002
COL.
NEW COLUMN
LINE
EXISTING
COLUMN LINE
ADDITIONAL INFORMATION
TITLE
SCALE:
B
WHICH SECTION
DRAWING SHEET NUMBER ON
OR DETAIL APPEARS
OR NUMBER
DESIGNATION LETTER
SECTION OR DETAIL
BIDDING SCOPE
NEW DOOR
EXISTING DOOR
EX.
XXXX
XXXX
ROOM NAME
BL-X
W-
STANDARD
DOOR NUMBER
SYMBOLSTANDARD ROOM
NAME TEXT AND
SYMBOL
BORROWED LIGHT
WINDOW TYPE
EQUIPMENT
TAG OR CODED
NOTE
FURNITURE
OR KEY NOTE
TAG
WALL
TYPE
FIXTURE
TAG
ROOM FINISHES TAG
ROOM NUMBER
GLAZING TYPEGL-
X DEMOLITION TAG
CPT-1
ROOM FINISHES TAG
X
X
XX-XX
XX-XX
X
XX-XX
X
XX-XX
ELEVATION
DESIGNATION
NUMBER
DRAWING NUMBER ON
WHICH ELEVATION
APPEARS; OR IS
MARKEDSTANDARD
EXTERIOR
ELEVATION TAG
STANDARD REVISION
TRIANGLE AND
BUBBLE
STANDARD
ENLARGED DETAIL
TAG
STANDARD
INTERIOR
ELEVATION TAG
DRAWING NUMBER
ON WHICH SECTION
OR DETAIL APPEARS
SECTION OR DETAIL
DESIGNATION
LETTER OR
NUMBER
AS-1 SIGNAGE
SYMBOL
NOT FOR
CONSTRUCTION
0 20 40 80
SCALE:
X
TYPICAL
DOOR-DETAIL
SCALE:
MATCH LINE "-"
SEE DRAWING----FOR CONTINUATION
LC
FINISH-FLOOR
ELEV=+0'-0"
CPT-1 ROOM FINISH
TAG
WORK POINT, CONTROL
POINT OR DATUM POINT
NORTH ARROW
N
ARCHITECTURAL SYMBOLS
NORTH
EAST
BASE
SOUTH
WEST
FLOOR
P3
PHOTO TAG
LI
N
E O
F
PR
O
TE
C
TI
O N
ADDITIONAL TWO (2)
WINDOW BAYS
REQUESTED TO BE
PROTECTED BY US
MARSHALLS
N
STAGING AND PROTECTION NOTES:
1) CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING CONSTRUCTION FROM DUST AND DAMAGE. REPAIR, REPLACE OR PATCH ANY EXISTING CONSTRUCTION DAMAGED DURING THE CONSTRUCTION PROCESS AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT. ANY DAMAGED AREAS SHALL BE RETURNED TO EQUAL OR BETTER CONDITION THAN THAT OF THE EXISTING CONSTRUCTION PRIOR TO DAMAGE.
2) CONTRACTOR STAGING AND PARKING IS LIMITED AND THE STAGING OF PARKING WILL NEED TO BE COORDINATED WITH THE GSA FOR EXACT LOCATION
AND AVAILABILITY PRIOR TO CONSTRUCTION.
3) WORK SHALL BE PHASED TO ACCOMMODATE CONTINUOUS, NORMAL OPERATION OF THE FACILITY. HEAVY NOISE, VIBRATION AND DUST PRODUCING
WORK IS TO BE COMPLETE OUTSIDE NORMAL OCCUPANT WORKING HOURS.
4) CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION NOT PART OF THIS CONTRACT INCLUDING WALLS, FLOORS, PLAZA, ETC. INTERIOR AND
EXTERIOR BARRIERS SHALL PROTECT EXISTING HISTORIC MATERIALS.
5) PROVIDE TEMPORARY CONSTRUCTION BARRIERS/ FENCING AS NECESSARY TO PREVENT ACCESS TO CONSTRUCTION AREAS AND PROTECT BUILDING
OCCUPANTS AND PEDESTRIANS DURING CONSTRUCTION ACTIVITIES.
6) CONTRACTOR TO PROVIDE TEMPORARY SIGNAGE, BARRIERS AND TRAFFIC CONTROLS TO DIRECT PEDESTRIAN AND BUILDING TRAFFIC AS NEEDED THROUGHT THE DURATION OF CONSTRUCTION. TEMPORARY SIGNAGE AND DIRECTIONAL INDICATORS SAHLL BE REVIEWED AND APPROVED BY GSA PROPERTY MANAGEMENT PRIOR TO PLACEMENT. COORDINATE WITH GSA PROJECT MANAGER AS REQURIRED FOR NECESSARY PERMISSIONS.
7) CONTRACTOR SHALL SAFEGUARD LIMESTONE SURROUNDING WORK AREAS DURING DEMOLITION AND INSTALLATION OF THE NEW ENTRANCE FRAMING.
PHASING SEQUENCE NOTES:
1) ACCESS TO REMAINING BUILDING'S ENTRANCES SHALL REMAIN OPEN AT ALL TIMES DURING NORMAL BUSINESS HOURS FOR THE DURATION OF THE CONSTRUCTION. NORMAL OCCUPANT BUSINESS HOURS ARE FROM 7:00 AM TO 5:00PM, MONDAY THROUGH FRIDAY.
2) DEMOLITION OF EXISTING DOORS, FRAMES AND ACCESS HARDWARE SHALL BE COORDINATED WITH BUILDING MANAGER AND US
MARSHALLS, AND BUILDING SCHEDULE.
3) AFTER COMPLETION OF ONE OF THE ENTRANCES CONTRACTOR SHALL VERIFY FUNCTIONALITY OF NEW DOORS AND ACCESS CONTROL
HARDWARE BEFORE PROCEEDING TO NEXT ENTRANCE.
4) CONTRACTOR SHALL NOT LEAVE CONSTRUCTION AREA UNSECURED. NO EXTERIOR VESTIBULES SHALL BE LEFT UNSECURED
OVERNIGHT FOR SECURITY REASONS.
5) WORK ABOVE CEILING OR IN WALL CAVITIES FOR CABLING CAN OCCUR DURING NORMAL BUSINESS HOURS. NOISE PRODUCING WORK
WILL BE LIMITED TO OFF HOURS AND WEEKENDS.
AD100
LH
LOWER
ARCHITECTURE
DEMOLITION PLAN
0 32'4' 8' 16' 1/16" = 1'-0"
DEMOLITION LOWER LEVEL PLAN1
AD100
0 8'1' 2' 4' 1/4" = 1'-0"
ENLARGED DEMOLITION PLAN2
AD100
P1
LOWER LEVEL
EXISTING CONDITIONS
SCALE:NTS
P2
LOWER LEVEL
EXISTING CONDITIONS
SCALE:NTS
P3
LOWER LEVEL
EXISTING CONDITIONS
SCALE:NTS
AD101
LH
ARCHITECTURE
DEMOLITION PLAN
0 32'4' 8' 16' 1/16" = 1'-0"
DEMOLITION FIRST FLOOR PLAN1
AD101
P1
FIRST LEVEL - STAIR 002
EXISTING CONDITIONS PHOTO
SCALE:NTS
P2
FIRST LEVEL - STAIR 002
EXISTING CONDITIONS PHOTO
SCALE:NTS
P3
FIRST LEVEL - TYPICAL WINDOW
EXISTING CONDITIONS PHOTO
SCALE:NTS
P4
FIRST LEVEL - WINDOW STOOL
EXISTING CONDITIONS PHOTO
SCALE:NTS
P5
FIRST LEVEL - EMPLOYEE DOOR
EXISTING CONDITIONS PHOTO
SCALE:NTS
P6
FIRST LEVEL - EMPLOYEE DOOR
EXISTING CONDITIONS PHOTO
SCALE:NTS
P8
ROTUNDA - EAST DOOR 0010
EXISTING CONDITIONS PHOTO
SCALE:NTS
P7
ROTUNDA - EAST DOOR 007A
EXISTING CONDITIONS PHOTO
SCALE:NTS
0 4'1' 2' 3/8" = 1'-0"
DEMOLITION ELEVATION4
AD101
0 4'1' 2' 3/8" = 1'-0"
DEMOLITION PLAN2
AD101
0 4'1' 2' 3/8" = 1'-0"
DEMOLITION PLAN3
AD101
A100
LH
LOWER
ARCHITECTURE
FLOOR PLAN
0 32'4' 8' 16' 1/16" = 1'-0"
LOWER LEVEL (SL1) FLOOR PLAN1
A100
TUN01
0 6" 4'1' 2' 1/2" = 1'-0"
PARTIAL FLOOR PLAN2
A100
A101
LH
ARCHITECTURE
FLOOR PLAN0 32'4' 8' 16'
1/16" = 1'-0"
FIRST FLOOR PLAN1
A101
COLUMN GRID
DETAIL MARK
KEY NOTES
DOOR NUMBER
WALL TYPE
ELEVATION/SECTION NUMBER
SHEET NUMBER
DOOR SCHEDULE KEY NUMBER
ELEVATION MARK
NEW DOOR
NEW PARTITION
EXISTING OR NIC PARTITION
XXX
1. PROVIDE NEW INTERIOR SECURITY GLAZING STOREFRONT
RETROFIT SYSTEM
0 16'2' 4' 8' 1/8" = 1'-0"
ENLARGED ROTUNDA FLOOR PLAN2
A101
A201
A201
A201
X
007A
007B
ST-02
11111
1 1 1 1
1 007A
007B
A501
A101
2 HOUR RATED FIRE PARTITION
A201
LH
ARCHITECTURE
EXTERIOR ELEVATIONS0 16'2' 4' 8'
1/8" = 1'-0"
EXTERIOR ELEVATION - WEST1
A2010 16'2' 4' 8'
1/8" = 1'-0"
PARTIAL EXTERIOR ELEVATION - NORTH (TYP.)2
A201
0 16'2' 4' 8' 1/8" = 1'-0"
EXTERIOR ELEVATION - EAST3
A201
1.
5'-103 4"
WINDOW TYPE
W-2
3'-111 4"
WINDOW TYPE
W-1
W-2 W-2 W-1 W-1 W-1
5'-103 4"
WINDOW TYPE
W-2
W-2
3'-111 4"
WINDOW TYPE
W-1
W-1 W-1 W-1 W-1 W-1 W-2
3'-11"
WINDOW TYPE
W-3
W-3 W-3 W-3
5'-11"
WINDOW TYPE
W-4
W-4 W-4 W-4
'-6
1 4"
EX
IS
TI
N
G C
U R
TA
IN
W
AL
L
'-9
1 4"
EX
IS
TI
N
G C
U R
TA
IN
W
AL
L
EXISTING CURTAINWALL
FRAMING IS FLUSH WITH
EXTERIOR STONE
FACADE; NEW WORK TO
BE INSTALLED INTERIOR
US MARSHALL'S
REQUESTED INCLUSION
IN SCOPE
NOTE:
SEE PLAN FOR FULL
ELEVATION SCOPE
'-9
4"
N
EW
IN
TR
SY
ST
EM
NEW INTERIOR
FRAMING SYSTEM TO
ALIGN WITH TOP OF
EXTERIOR MULLION
'-9
1 4"
EX
IS
TI
N
G C
U R
TA
IN
W
AL
L
'-9
1 4"
N
EW
IN
TR
SY
ST
EM
NEW INTERIOR SECURITY
GLAZING SYSTEM TO
HAVE INTERMEDIATE
MULLION, SEE SECTIONS
NEW INTERIOR SECURITY
GLAZING SYSTEM TO
HAVE INTERMEDIATE
MULLION, SEE SECTIONS
A A501
A A501
B A501
1. WINDOW TYPES ARE LISTED FOR QUANTITY AND
APPROXIMATE SIZES. CONTRACTOR TO VERIFY ALL
EXISTING CONDITIONS AND DIMENSIONS.
WINDOWS & DOORS IN SCOPE
A A501
WINDOW SCHEDULE
NO.
SIZE
WIDTH HEIGHT
W-1 11'-9 1/4"3'-11 1/2"
5'-10 3/4"W-2 W-3 W-4
11'-9 1/4" 3'-11" 5'-11"
MULTI-STORY
MULTI-STORY
A501
LH
ARCHITECTURE
SECTIONS AND DETAILS0 6" 4'1' 2'
1/2" = 1'-0"
ENLARGED PARTIAL PLAN1
A501
A501
0 6"3"1" 3" = 1'-0"
ENLARGED PLAN DETAIL5
A501
A A501
0 6" 4'1' 2' 1/2" = 1'-0"
TYPICAL WALL SECTIONA
A501
A501
A501
0 6"3"1" 3" = 1'-0"
SECTION DETAIL-MIDSPAN4
A501
'-9
1 4"
EX
IS
TI
N
G C
U R
TA
IN
W
AL
L
SY
ST
EM
5' -1
01 2"
TY
PI
C
AL
P
AN
E
W
IN
D O
W 3'
-1 0"
TY
PI
C
AL
P
AN
E
W
IN
D O
W
0 6"3"1" 3" = 1'-0"
SECTION DETAIL - WINDOW SILL3
A501
'-9
1 2"
N
EW
IN
TE
R
IO
R F
R
AM
IN
G
S
YS
TE
M
8' -0
M
AX
. H
EI
G
H T
O F
SC
O
PE
CONTRACTOR TO
DEMOUNT AND
RE-ATTACH EXISTING
BLINDS SO AS TO BYPASS
NEW STOREFRONT
BELOW; PATCH AND
REPAINT GWB SOFFIT.
714"
EXISTING
CURTAINWALL
6"
2"x2"x1/4" STEEL TUBE, FULL
WIDTH OF WINDOW OPENING
WELDED TO END PLATES
ALIGNMENT TYPICALLY
CENTERED ON EXISTING
CURTAINWALL/STOREFRONT
MULLION
RIOT GLASS
ARMORPLAST GEN II
SECURITY FRAMING W/
AP375BR GLAZING PANEL
1"
NEW FRAMING SET BACK
FROM REAR FACE OF
EXISTING CURTAINWALL
RIOT GLASS
ARMORPLAST GEN II
SECURITY FRAMING W/
AP375BR GLAZING PANEL
ATTACHMENT ANCHORING AS
REQUIRED BY MANUFACTURER
TO MEET ASTM STANDARDS
AND ENSURE ADEQUATE
ENGAGMENT TO STRUCTURE
BELOW SILL.
UNSECURED SIDE
EXTERIOR PLAZA
SECURED SIDE
CONTRACTOR TO REMOVE
EXISTING GWB TO VERIFY THAT
ANCHORS WILL FULLY ENGAGE
EXISTING JAMB STRUCTURE
PRIOR TO INSTALLING ALL WORK.
1"
714"
EXISTING
CURTAINWALL
6"
RIOT GLASS
ARMORPLAST GEN II
FRAMING W/ AP375BR
GLAZING PANEL
0 6" 4'1' 2' 1/2" = 1'-0"
SOUTHWEST CURTAIN WALL SECTIONB
A501
2' -1
PROVIDE ANCHORS SUFFICIENT
LENGTH ENOUGH TO ENGAGE
EXISTING STRUCTURE ON ALL
SIDES PER MANUFACTURER
SPACING REQUIREMENTS TO
MEET ASTM STANDARD
1"
LOCATE NEW ALUMINUM
SECURITY GLAZING
STOREFRONT SYSTEM
1" BACK FROM EXISTING
CURTAINWALL
1' -1
11 4" 2'
-0
1' -1
11 4"
RIOT GLASS ARMORPLAST
GEN II MIDSPAN FRAMING
CHANNEL; AP2-MULL. ALIGN
WITH CL OF EXISTING
CURTAIN WALL MULLION.
RIOT GLASS ARMORPLAST
GEN II MIDSPAN FRAMING
CHANNEL; AP2-MULL. ALIGN
WITH CL OF EXISTING
CURTAIN WALL MULLION.
5' -5
4"
RIOT GLASS ARMORPLAST
GEN II MIDSPAN FRAMING
CHANNEL; AP2-MULL.
EXISTING WOOD WINDOW
STOOL BELOW
CONTRACTOR TO PROVIDE ANCHORS
OF SUFFICIENT LENGTH TO EMBED
INTO EXISTING STRUCTURE IN ORDER
TO MEET REQUIREMENTS OF
SECURITY GLAZING SYSTEM
MANUFACTURER AND ASTM
STANDARD.
RIOT GLASS ARMORPLAST
GEN II MIDSPAN FRAMING
CHANNEL; AP2-MULL. ALIGN
WITH CL OF EXISTING
CURTAIN WALL MULLION.
3' -1 1"
3' -1 1"
'-0
EXISTING CURTAINWALL
RIOT GLASS ARMORPLAST
GEN II MIDSPAN FRAMING
CHANNEL; AP2-MULL. ALIGN
WITH CL OF EXISTING
CURTAIN WALL MULLION.
0 8'1' 2' 4' 1/4" = 1'-0"
ENLARGED PARTIAL PLAN2
A501
A501
SIM.
W-2
W-1
W-3
W-4
W-4
W-3
W-3
B A501
3'-11"
3'-11"
3'-11"
5'-11"
5'-11"
RIOT GLASS
ARMORPLAST GEN II
FRAMING W/ AP375BR
GLAZING PANEL
W-4
5'-11
F1/ FL
SINGLE DOOR
LOBBY
A
F3/ FL
DOUBLE DOOR
A A
F4/FL
DOUBLE DOOR
A A
F5/NL
DOUBLE DOOR
A A
66" R/O (+/-)
1/2"
2 1/4"
1/4"
64 1/2" F/D
65" S/O
60" D/O
1/2"
2 1/4"
1/4"
5 6
3 3
THREAT
SECURE
" R
/O
" D
/O
/4 " F
/D
/2 " S
/O 1/
2"
1/
4"
1/ 4"
THREAT
SECURE
41 1/4" R/O
1/2"
2 1/4"
1/4"
36" D/O
39 3/4" F/D
40 1/4" S/O 1/2"
1 1/2"
1/4"
" R
/O
/4 " F
/D
/2 " S
/O
" D
/O
1/ 2" 3
1/ 4"
1/ 4"
THREAT
SECURE
F2/ F
SINGLE DOOR
STAIR ST-02
A601
SFS
LH
ARCHITECTURE
DOOR SCHEDULE
DOOR SCHEDULE LEGEND
1. PROVIDE HINGES WITH NON-REMOVABLE HINGE PINS AT ALL OUTSWINGING DOORS
ACCESSING GOVERNMENT OCCUPIED SPACE FROM PUBLIC SPACE.
2. VERIFY ALL KEY REQUIREMENTS WITH OWNER.
3. ALL DOOR FINISHES TO MATCH EXISTING CONDITIONS.
4. ALL DOORS AND FRAMES MUST MEET ASTM F3038-21 STANDARD FOR 15 MINUTE FORCE
ENTRY PROTECTION.
5. DOOR HARDWARE LISTS ARE SHOWN FOR ONE DOOR CONFIGURATION BASED ON TYPE,
GC TO COORDINATE DOOR QUANTITY AND TYPE FOR EACH LOCATION.
6. IF DOOR IS LOCATED IN A FIRE-RESISTANT ASSEMBLY, THE HARDWARE MUST BE UL-LISTED
FOR THE FIRE-RESISTANCE RATING. (LISTED IN ACCORDANCE WITH UL10C AND UL305)
8' -2
1 2"
3'-10"
7' -2
1 2"
6'-6"
EXISTING FRAME
AND TRANSOM
GLAZING TO REMAIN
DOOR OPERATION GENERAL NOTES:
DOORS THAT ALLOW PASSAGE/ ENTRY ARE TO OPERATE AS FAIL SECURE.
DOORS REMAIN UNLOCKED DURING NORMAL BUSINESS HOURS, TYPICALLY 7AM TO 5PM.
WHEN EMERGENCY DISTRESS BUTTON IS DEPRESSED, INTER-CONNECTED DOORS
HARDWARE WILL ACTIVATE AND LOCK DOWN.
AT ALL TIMES, DOORS WITH PANIC BAR/ LEVERSET CAN RETRACT HARDWARE AND ALLOW
FREE EGRESS.
EX
IS
TI
N
G C
U R
TA
IN
W
AL
L
TO
R
EM
AI
N
'-2
6'-101 2"
'-2
4"
1' -0
2'
-9
4" 3"
6'-101 2"
3"3"
DOOR TYPE GENERAL NOTES
DOOR SCHEDULE
NO.
DOOR FRAME
REMARKSTYPE
SIZE MATERIAL
FINISH TYPE MATERIAL
DETAILS
WIDTH HT THK HEAD JAMB
STEEL
FRAME
ST-02 F STL-PNT F2
H-1
NL F5
2-1/4"7'-0"3'-6" 007B 007A
TUN01
8'-0" 10'-2" 10'-0" 7'-0"
H-1 J-1/J-2
H-1 H-1 H-2
2, 3, 5, 6
DB
STL-PNT
2-3/4" 2-3/4" 2-3/4" 2-1/4"
STL
STL
STL
STL
STL
FL
FL
FL
3'-4" 2@ 3'-2 1/4"
2@ 3'-0"
F1 F4 F3
REMARKS LEGEND:
1. DOORS TO HAVE AUTOMATIC OPERATORS, SEE HARDWARE SCHEDULE
2. EXISTING HEADER AND TRANSOM WINDOWS TO REMAIN. COORDINATE PROTECTION
AND REINFORCEMENT IN FIELD.
3. PATCH AND REPAIR ANY ADJACENT STONE SURFACE (BOTH FLOOR AND WALLS) PRIOR
TO INSTALLATION OF NEW WORK.
4. DOOR FINISH TO MATCH EXISTING ADJACENT DOOR FRAME
5. DOOR AND FRAME TO BE PAINTED STEEL. COORDINATE COLOR WITH SITE FACILITIES.
6. DOOR AND HARDWARE TO BE COMPLIANT WITH FIRE RATED ASSEMBLY.
1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 5, 6
S2 S1 S4 S3 S5
ALUMINUM
HOLLOW METAL
PAIR
PAINTED
NOT IN CONTRACT
TEMPERED AND STC LAMINATED GLAZING
ALUM
HM
PR
PTD
NIC
T
EXISTING TO REMAINEX
DARK BRONZEDB
STEELSTL
STEEL - PAINTEDSTL-PNT
SECURITY GLAZINGSC
DB
FORCED ENTRY RESISTANT DOOR
DOUBLE DOOR LOCKING REQUIREMENTS
SCALE:NTS
XX
FORCED ENTRY RESISTANT DOOR
SINGLE DOOR LOCKING REQUIREMENTS
SCALE:NTS
DOOR LEAF ESTIMATED WEIGHT: 648 LBS
POWER REQUIREMENT: 120V SINGLE PHASE
BASIS OF DESIGN: NOTE:
NORSHIELD SDR MAX
ASTM F3038-21 COMPLIANT
HOT DIP GALVANIZED
PRIME PAINTED
1 EA REQUIRED
TUBE SUBFRAME FOR DOOR TO BE
1/2" X 6" STEEL PLATES HOT
DIPPED GALVANIZED PRIME
PAINTED SHIPPED KD
1 SET REQUIRED PER DOOR
FRAME TYPES
SCALE: 1/4"=1'-0"
STL-PNT
DOOR FIRE
RESISTANCE
RATING
90 MIN.
90 MIN.
DOOR LEAF ESTIMATED WEIGHT: 648 LBS
POWER REQUIREMENT: 120V SINGLE PHASE
BASIS OF DESIGN: NOTE:
NORSHIELD SDR MAX
ASTM F3038-21 COMPLIANT
HOT DIP GALVANIZED
PRIME PAINTED 1 EA
REQUIRED
TUBE SUBFRAME FOR DOOR TO BE
1/2" X 6" STEEL PLATES HOT
DIPPED GALVANIZED, PRIME
PAINTED SHIPPED
2@ 3'-2 1/4"
EXISTING FRAME
AND TRANSOM
GLAZING TO REMAIN
3'-9"
TUBE SUBFRAME
FOR DOOR TO BE
1/2" X 6" STEEL
PLATES HOT DIPPED
GALVANIZED, PRIME
PAINTED SHIPPED
7' -2
1 2"
3'-103 4"
6'-91 2" 6'-91
2" 6'-5"
STEEL SURROUND FRAMES
SCALE: 1/4"=1'-0"
S1 DOOR 007B
MATERIALS BY VENDOR:
STL-C-1 6" X 1/2" A500 GRADE B
STL-C-2 6" X 1/2" A500 GRADE B
STL-C-3 6" X 1/2" A500 GRADE B
ST
L-
C -1
ST
L-
C -3
STL-C-2
3'-10"
8' -3
S2 DOOR ST-02
MATERIALS BY VENDOR:
STL-C-4 6" X 1/2" A500 GRADE B
STL-C-5 6" X 1/2" A500 GRADE B
STL-C-6 6" X 1/2" A500 GRADE B
ST
L-
C -4
ST
L-
C -6
STL-C-5
3'-10"
7' -3
" ST
L-
C -7
STL-C-8
ST
L-
C -9
6'-101 2"
'-2
S3 DOOR 010
MATERIALS BY VENDOR:
STL-C-7 6" X 1/2" A500 GRADE B
STL-C-8 6" X 1/2" A500 GRADE B
STL-C-9 6" X 1/2" A500 GRADE B
S4 DOOR 007A
MATERIALS BY VENDOR:
STL-C-10 6" X 1/2" A500 GRADE B
STL-C-11 6" X 1/2" A500 GRADE B
STL-C-12 6" X 1/2" A500 GRADE B
S5 DOOR TUN01
MATERIALS BY VENDOR:
STL-C-13 6" X 1/2" A500 GRADE B
STL-C-14 6" X 1/2" A500 GRADE B
STL-C-15 6" X 1/2" A500 GRADE B
ST
L-
C -1
STL-C-11
ST
L-
C -1
6'-101 2"
'-2
4"
ST
L-
C -1
ST
L-
C -1
STL-C-14
6'-6"
7' -3
4"
S-2
J-2
H-2
SIM
H-1
SIM
H-1
H-1 H-1
J-3 J-3 J-1 J-1 J-1 J-1 J-1
S-2
J-1/J-2 J-1/J-3 J-1/J-3 J-1/J-3
J-2
PROVIED U.L. COMPLIANT DOOR AND
HARDWARE IN RATED WALLS, VERIFY
EQUIPMENT WITH MANUFACTURER
PROVIED U.L. COMPLIANT DOOR AND
HARDWARE IN RATED WALLS, VERIFY
EQUIPMENT WITH MANUFACTURER
FIELD WELD ALL
CORNERS, TYP.
A602
LH
N/A
ARCHITECTURE
DOOR DETAILS
J-2
LATCH SIDE
JAMB-DETAIL
SCALE: 3" = 1'-0"
SECURE
SIDE
THREAT
SIDE1 1/2"
1/4" 1/2"
3/16"
DOOR OPENING
FRAME DIMENSION
STEEL OPENING
ROUGH OPENING
ATTACHMENT NOTE:
ANCHORS NOTED ARE FOR USE IN SOLID FILLED CMU
OR REINFORCED CONCRETE. PLEASE PROVIDE NOTICE
IF WALL IS OTHER MATERIALITY FOR COORDINATION OF
THE PROPER ANCHORING SYSTEM.
6" X 1/2" A500 GRADE B STEEL FRAME
1/16" PLASTIC HORSESHOE SHIM. FULLY SHIM EACH ANCHOR.
FIELD DRILL & TAP PLATE FOR M12 X 25 SCKT HD CAP SCREW,
CLASS 12.9, W/ HIGH STRENGTH WASHER @ 12" O.C.
FIELD INSTALL CAP PLUGS AFTER INSTALLATION OF ANCHORS
4"
4"
BACKER ROD & SEALANT
J-1
HINGE SIDE W/ PLATE
JAMB-DETAIL
SCALE: 3" = 1'-0"
THREAT
SIDE
2 1/4"
1/4"
1/2"
1/16"
DOOR OPENING
FRAME DIMENSION
STEEL OPENING
ROUGH OPENING
BACKER ROD & SEALANT
6" X 1/2" A500 GRADE B STEEL FRAME
1/16" PLASTIC HORSESHOE SHIM. FULLY SHIM EACH ANCHOR.
FIELD DRILL & TAP PLATE FOR M12 X 25 SCKT HD CAP SCREW,
CLASS 12.9, W/ HIGH STRENGTH WASHER @ 12" O.C.
FIELD INSTALL CAP PLUGS AFTER INSTALLATION OF ANCHORS
HILTI HY200 ADHESIVE ANCHORING SYSTEM.
FIELD DRILL 9/16"Ø HOLE 6" DEEP FOR M12 X 200
THREADED ROD @ 12" O.C.
CUSTOM FIELD APPLIED OVERLAY FINISH
S-2
THRESHOLD
SILL-DETAIL
SCALE: 3" = 1'-0"
J-3
DOUBLE DOOR
JAMB-DETAIL
SCALE: 3" = 1'-0"
H-1
DOOR W/ OPERATOR
HEAD-DETAIL
SCALE: 3" = 1'-0"
H-2
DOOR ALT
HEAD-DETAIL
SCALE: 3" = 1'-0"
AUTOMATIC DOOR
OPERATOR,SEE SCHEDULE
EXISTING CURTAIN WALL
TO REMAIN
1/4" STEEL MOUNTING
PLATE, PAINT TO MATCH
EXSTG STOREFRONT
NEW DOOR FRAME, PAINTED TO
MATCH EXISTING STOREFRONT
6" X 1/2" A500 GRADE B
STEEL FRAME
SECURE
SIDE
THREAT
SIDE
4"
HILTI HY200 ADHESIVE ANCHORING SYSTEM.
FIELD DRILL 9/16"Ø HOLE 6" DEEP FOR M12 X 200
THREADED ROD @ 12" O.C.
THREAT
SIDE
SECURE
SIDE
SEE
SCH.
ADA COMPLIANT THRESHOLD;
FINISH TO MATCH DOOR
FIELD DRILL 7/16" HOLE, MIN. 2" DEEP;
PROVIDE #10x2" FLAT HD SS MACHINE
SCREW W/ HILTI HUD-1 ANCHOR
1/ 4"
1/ 2"
D O
O R
O
PE
N
IN
G
FR
AM
E
D
IM
EN
SI
O N
TU
BE
/R O
U G
H O
PE
N
IN
G
SECURE
SIDE
THREAT
SIDE
2"
1/ 4"1/
2"
FR
AM
E
O
PE
N
IN
G
ST
EE
L
O
PE
N
IN
G R
O U
G H
O
PE
N
IN
G
1 4"
D O
O R
O
PE
N
IN
G
AUTOMATIC DOOR
OPERATOR,SEE SCHEDULE
EXISTING HEADER TO REMAIN
NEW DOOR FRAME, PAINTED
6" X 1/2" A500 GRADE B
STEEL FRAME
1/4" STEEL MOUNTING PLATE,
PAINT TO MATCH EXSTG
STOREFRONT
SEE
SCH.
SECURE
SIDE
THREAT
SIDE
SE
E
SC
H
16"3
4"
SE
E
SC
H
SEE SCHEDULE
FOR TYPE
SECURITY GENERAL NOTES
A. ALL WORK IN THIS PROJECT SHALL CONFORM TO THE
REQUIREMENTS OF THE CURRENTLY ENFORCED BUILDING CODE,
LOCAL AND NATIONAL ELECTRICAL CODES, INCLUDING ALL
AMENDMENTS AND REVISIONS.
B. EXAMINE THE SITE, EXISTING EQUIPMENT AND LOCAL CONDITIONS
AFFECTING THE WORK. REPORT ANY FORESEEABLE PROBLEMS,
INTERFERENCES AND CONFLICTS DUE TO SITE CONDITIONS. REPORT
TO ENGINEER TO OBTAIN INSTRUCTIONS. NO ALLOWANCES WILL BE
MADE SUBSEQUENTLY FOR CONSIDERATION BECAUSE OF
OVERLOOKED CONDITIONS.
C. UNLESS OTHERWISE INDICATED, MOUNTING ELEVATIONS ARE
CENTERLINE ELEVATIONS.
D. OPENINGS AROUND PENETRATIONS OF TELECOM AND SECURITY
CABLES, RACEWAYS, AND CABLE ROUTING ASSEMBLIES THROUGH
FIRE RESISTANT RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS
SHALL BE FIRE STOPPED USING APPROVED METHODS TO MAINTAIN
THE FIRE RESISTANCE RATING IN ACCORDANCE WITH NFPA 70,
ARTICLES 725 & 800.
E. PLENUM RATED CABLES SHALL BE INSTALLED IN PLENUM RATED
SPACES. TELECOM AND SECURITY CABLES, WIRES, RACEWAYS, AND
CABLE ROUTING ASSEMBLIES INSTALLED IN PLENUM SPACES SHALL
BE LISTED IN ACCORDANCE WITH NFPA 70, ARTICLES 725 & 800.
F. PROVIDE ALL MATERIAL, EQUIPMENT AND LABOR TO COMPLETE THE
SECURITY WORK AS SHOWN ON DRAWINGS.
G. READ THE SECURITY DRAWINGS AND SPECIFICATIONS, IN
CONJUNCTION WITH ARCHITECTURAL, STRUCTURAL, CIVIL,
MECHANICAL, ELECTRICAL AND LANDSCAPING DRAWINGS AND
SPECIFICATIONS. REPORT ANY DISCREPANCIES AND OR
DISAGREEMENTS TO THE ENGINEER FOR CLARIFICATIONS AND
INSTRUCTIONS.
H. MAINTAIN ALL OPERATIONAL BUILDING SERVICES. THE SHUT DOWN
OF SERVICES SHALL ONLY TAKE PLACE AS AUTHORIZED BY THE GSA.
I. COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL
ELEVATIONS AND DETAILS. ARCHITECTURAL ELEVATIONS AND
DETAILS TAKE PRECEDENCE OVER LOCATIONS SHOWN ON SECURITY
DRAWINGS.
J. CONTRACTOR SHALL REFER TO THE SECURITY DRAWING PLANS,
DETAILS, DIAGRAMS, AND SCHEDULES FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
K. NO WIRING DEVICES OR OUTLET BOXES SHALL BE INSTALLED
BACK-TO-BACK. CONTRACTOR SHALL COORDINATE ALL DEVICE AND
OUTLET MOUNTING PRIOR TO INSTALLATION OF AFFECTED DEVICES
AND OUTLETS.
L. DRAWINGS REPRESENT SECURITY DESIGN INTENT. CONTRACTOR
SHALL FURNISH, INSTALL, AND SIZE ALL DEVICES, EQUIPMENT, AND
OTHER APPURTENANCES NECESSARY TO EXECUTE THE CONTRACT
DOCUMENTS TO COMPLETION.
SECURITY SYSTEM SYMBOLS SECURITY SYSTEM REQUIREMENTS
SECURITY SYSTEM CARD READER.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
CR
DC SECURITY SYSTEM DOOR CONTACT/SENSOR.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
LD SECURITY SYSTEM LOCKDOWN BUTTON.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
ML SECURITY SYSTEM MAGNETIC LOCK.
GP GALLAGHER SECURITY SYSTEM ACCESS CONTROL PANEL.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
AD AUTOMATIC DOOR OPERATOR.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
RX SECURITY SYSTEM REQUEST-TO-EXIT.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
RB SECURITY SYSTEM RELEASE BUTTON.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
ES SECURITY SYSTEM ELECTRIC STRIKE.
PROVIDE AND INSTALL ACCESS CONTROL CABLES, DEVICES, AND ANY
ASSOCIATED MOUNTING HARDWARE. REFER TO SECURITY DRAWINGS,
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
T000
BGF
MS
NA
SECURITY
SYMBOL LEGEND
CR
UNSECURE SIDE
SECURE SIDE
RX
TUN01
TD100
BGF
MS
LOWER
SECURITY
DEMOLITION PLAN
0 32'4' 8' 16'
1/16" = 1'-0"
DEMOLITION LOWER LEVEL (SL1) PLAN1
AD100
P1
LOWER LEVEL
EXISTING CONDITIONS
CR
C
R
RB
ML
007A
007B
ST-02
AD
A
D
A
D
A
D
TD101
BGF
MS
SECURITY
DEMOLITION PLAN
0 32'4' 8' 16'
1/16" = 1'-0"
DEMOLITION FIRST FLOOR PLAN1
TD101
P1
FIRST LEVEL - STAIR 002
EXISTING CONDITIONS PHOTO
SCALE:NTS
P2
FIRST LEVEL - EMPLOYEE DOOR
EXISTING CONDITIONS PHOTO
SCALE:NTS
P4
ROTUNDA - EAST DOOR 0010
EXISTING CONDITIONS PHOTO
SCALE:NTS
P3
ROTUNDA - EAST DOOR 007A
EXISTING CONDITIONS PHOTO
TUN01
DC DC
ES
CR
T011
BGF
MS
L1
SECURITY
FLOOR PLAN
0 32'4' 8' 16'
1/16" = 1'-0"
LOWER LEVEL (SL1) FLOOR PLAN1
T011
G
P
G
P
G
P
EXISTING ACCESS
CONTROL PANEL
EXISTING ACCESS
CONTROL PANEL
T012
BGF
MS
L2
SECURITY
FLOOR PLAN
0 32'4' 8' 16'
1/16" = 1'-0"
LOWER LEVEL (SL2) FLOOR PLAN1
T012
X
007A
007B
ST-02DC
LD
DC1 ES
2 DC DC
ES
ES
ESDC
DC
CR
CR
RB AD
AD
AD
AD
T101
BGF
MS
SECURITY
FLOOR PLAN
0 32'4' 8' 16' 1/16" = 1'-0"
FIRST FLOOR PLAN1
T101
X
L
D
P1
T112
BGF
MS
SECURITY
FLOOR PLAN
0 32'4' 8' 16'
1/16" = 1'-0"
TWELFTH FLOOR PLAN1
T112
X
P1
LEVEL 12
EXISTING CONDITIONS
CAT 6 CABLE
CAT 6 CABLE
CAT 6 CABLE
POWER SUPPLY CABLE
RED JACKETED, 2
CONDUCTOR, #22
AWG CABLE
JUNCTION BOX
CR RX DC ES
TELECOM ROOM
120VAC
FIRE ALARM
CONTROL PANEL
LOCAL DOOR
CONTROLLER(S)
SECURITY DESK 012
FLOOR 1
ACCESS
CONTROL
PANEL
CAT 6
PATCH PANEL
CARD
READER(S)
EXISTING
ORANGE JACKETED,
6 CONDUCTOR, #22
AWG CABLE
ACS
HEADEND/SERVER
JUNCTION BOX
LOCAL DOOR
CONTROLLER(S)
CAT 6A CABLE
AD
ADA
PUSH
BUTTON(S)
ADA
OPERATOR
POWER
SUPPLY
SECURITY
PoE
SWITCH
CAT 6 CABLE
EXISTING
BLUE JACKETED,
4 CONDUCTOR,
#22 AWG CABLE
REQUEST-TO-EXIT
MOTION SENSOR OR
RELEASE BUTTON
DOOR
CONTACT(S)
ELECTRIC
STRIKE
WHITE JACKETED,
2 CONDUCTOR,
#22 AWG CABLE
GRAY JACKETED,
4 CONDUCTOR,
#18 AWG CABLE
DC
DOOR
CONTACT(S)
WHITE JACKETED,
2 CONDUCTOR,
#22 AWG CABLE
LD
LOCK
DOWN
BUTTON
BLUE JACKETED,
4 CONDUCTOR,
#22 AWG CABLE
US MARSHAL
CONTROL ROOM 146
FLOOR 12
LD
LOCK
DOWN
BUTTON
BLUE JACKETED,
4 CONDUCTOR,
#22 AWG CABLE
EXISTING ORANGE
JACKETED,
4 CONDUCTOR,
#18 AWG CABLE
NOTE:
ACTIVATION OF FIRE ALARM SHALL
NOT TRIGGER ACTIVATION OF
LOCKDOWN.
PLAN
SYMBOLLDLOCKDOWN BUTTON
DIVISION 26:
(1) 4" SQUARE x 2 1/8" DEEP BACK BOX WITH SINGLE GANG MUD RING.
(1) 1" CONDUIT, STUBBED OUT 90 DEGREES, TO THE NEAREST ACCESSIBLE CABLE
TRAY OR CEILING END OF CONDUIT STUB SHALL BE FIT WITH A PLASTIC BUSHING.
DIVISION 28:
(1) BLUE JACKETED, 4-CONDUCTOR, #22 AWG CABLE.
(1) COVERED LOCKDOWN BUTTON WITH KEYED RESET.
DIVISION 28 NOTES:
1. REFER TO SHEET T500 FOR ACCESS CONTROL SYSTEM DIAGRAM FOR WIRING
CONNECTIONS.
PUSH
HERE
LIFT HERE
KEYED RESET
LOCKDOWN
BUTTON
LOCKDOWN
BUTTON COVER
PLATE
T500
BGF
MS
NA
SECURITY
SECURITY DETAILS
ACCESS CONTROL SYSTEM DIAGRAM1
T500
LOCKDOWN BUTTON DETAIL2
T500
| OH0301ZZ-G001 |
| SHEET G001 |
| OH0301ZZ-G002 |
| SHEET G002 |
| OH0301ZZ-AD100 |
| SHEET AD100 |
| OH0301ZZ-AD101 |
| SHEET AD101 |
| OH0301ZZ-A100 |
| SHEET A100 |
| OH0301ZZ-A101 |
| SHEET A101 |
| OH0301ZZ-A201 |
| SHEET A201 |
| OH0301ZZ-A501 |
| SHEET A501 |
| OH0301ZZ-A601 |
| A601-24x36 |
| OH0301ZZ-A602 |
| OH0301ZZ-T000 |
| OH0301ZZ-TD100 |
| OH0301ZZ-TD101 |
| OH0301ZZ-T011 |
| OH0301ZZ-T012 |
| OH0301ZZ-T101 |
| OH0301ZZ-T112 |
| OH0301ZZ-T500 |
File details come from the government source that posted it. Updated .