Binghamton 1st Floor_AE600.pdf
PDF 3 MB Posted
- Solicitation number
- 47PC5326R0002
- Issued by
- Not on record
About this file
This is an architectural drawing document for a GSA renovation project located at 15 Henry Street, Binghamton, NY 13901, consisting of door schedules, security hardware diagrams, and related specifications for first floor build-out construction. The document is prepared by N.K. Bhandari Architecture & Engineering, P.C. and C&S Engineers as the prime and sub A/E firms respectively, with GSA as the federal agency overseeing the project.
The door schedule specifies requirements for 19 doors ranging from 3'0" to 3'6" in width and 6'0" to 7'0" in height, all 1¾" thick. All doors are Type F (Flush) with hollow metal (HM) frames in painted finish (PNT3), featuring various hardware sets and access control configurations. Security specifications include electronic locks, electrified hinges, proximity card readers, keypads, and electronic strikesets with fail-secure operation and free egress capabilities. Sound control ratings include STC 45 and STC 50 ratings for designated doors with perimeter seals and automatic door bottoms. Fire-rated openings are specified where required, with ratings certified by UL, Intertek/Warnock Hersey, or Factory Mutual. Installation and testing requirements are mandated, with coordination between the General Contractor (GC) for door, frame, and wall preparation and the Security Contractor (SC) for device wiring. All hardware and access control devices must comply with Architectural Barriers Act Accessibility Standards (ABAAS) heights unless otherwise noted. The document includes detailed specifications on frame construction, storage protocols, and operational descriptions for various access control scenarios.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYPE H1
HOLLOW METAL
WELDED FRAME
0' - 2" 0' - 2"
DOOR WIDTH
TYPE F
FLUSH
NOTE: DOOR TYPES ARE GENERALLY BASED ON STEEL DOOR INSTITUE STANDARD STYLES
TYPE F-A
FLUSH ACOUSTICAL
TYPE F-RF
FLUSH RF SHEILDED
THREAT SIDE SECURE SIDE
JUNCTION BOX -
MOUNTED TO FRAMING
OR STRUCTURE (GC)
ELEC. HINGE (GC)
ELEC. LOCKSET (GC)
LATCH GUARD (GC) (IF
SCHEDULED)
ACCESS CONTROL
KEYPAD/ CARD READER
(SC)
BOX FOR KEYPAD/CARD
READER (GC)
ELEC. LOCKSET (GC)
CONDUIT TO J-BOX (GC)
DOOR CLOSER (GC)
CONDUIT W/ PULL
STRING TO J-BOX JUST
ABOVE CEILING (GC)
M
IR
R O
R I M
A G
E
NOTE:ALL HARDWARE AND ACCESS CONTROL DEVICES SHOULD BE MOUNTED AT STANDARD ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) HEIGHT UNLESS OTHERWISE NOTED. ALL DOOR, FRAME, AND WALL PREP BY GC. WIRING OF DEVICES BACK TO SECURITY PANEL BY SC.
GC - GENERAL CONTRACTOR
SC - SECURITY CONTRACTOR HIRED BY GC
FINISH FLOOR
B.O. DECK
CEILING
EMT CONDUIT W/ PULL STRING TO
POWER SUPPLY/ ACCESS CONTROL
PANEL (10th FLOOR, SEE ELECTRICAL
NOTES) (GC). CABLING TO TENANT
POWER SUPPLY/ ACCESS CONTROL
PANEL (SC)
(305)
1' - 0" (1
SCHEDULED WALL
CONSTRUCTION
HOLLOW METAL
FRAME
SCHEDULED
DOOR
JAMB BEYOND
20 GA. DOUBLE
METAL STUDS
SCHEDULED WALL
CONSTRUCTION
20 GA. DOUBLE
METAL STUDS,
FULL HEIGHT
HOLLOW METAL
FRAME
SCHEDULED
DOOR
S E
E P
L A
N S
V A
R
IE
S
SECURE WALL
CONSTRUCTION (REFER TO
PARTITION TYPES)
14 GA. COLD ROLLED STEEL
TELESCOPING FRAME FRAME
COLD ROLLED STEEL
DOOR
JAMB BEYOND
16 GA. DOUBLE
METAL STUDS
5" MIN.- 6-1/4" MAX
SOUND DEADENING
MATERIAL IN JAMB
THREAT SIDE SECURE SIDE
JUNCTION BOX -
MOUNTED TO FRAMING
OR STRUCTURE (GC)
ELEC. HINGE (GC)
ELEC. LOCKSET (GC)
LATCH GUARD (GC) (IF
SCHEDULED)
ACCESS CONTROL
KEYPAD/ CARD READER
(SC)
BOX FOR KEYPAD/CARD
READER (GC)
ELEC. LOCKSET (GC)
CONDUIT TO J-BOX (GC)
DOOR CLOSER (GC)
CONDUIT W/ PULL
STRING TO J-BOX JUST
ABOVE CEILING (GC)
M
IR
R O
R I M
A G
E
NOTE:ALL HARDWARE AND ACCESS CONTROL DEVICES SHOULD BE MOUNTED AT STANDARD ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) HEIGHT UNLESS OTHERWISE NOTED. ALL DOOR, FRAME, AND WALL PREP BY GC. WIRING OF DEVICES BACK TO SECURITY PANEL BY SC.
GC - GENERAL CONTRACTOR
SC - SECURITY CONTRACTOR HIRED BY GC
FINISH FLOOR
B.O. DECK
CEILING
EMT CONDUIT W/ PULL STRING TO
POWER SUPPLY/ ACCESS CONTROL
PANEL (10th FLOOR, SEE ELECTRICAL
NOTES) (GC). CABLING TO TENANT
POWER SUPPLY/ ACCESS CONTROL
PANEL (SC)
(305)
1' - 0" (1
(1) HC-30 ELECTRIFIED
CAM-LIFT HINGE (AS REQ.)
(2) HC-30 CAM-LIFT
HINGES
E Q
E
Q
C E
N T
E R
O F
L K
M
PERIMETER SOUND SEAL
16 GA. DOUBLE METAL
STUDS, FULL HEIGHT
M
IN
-1
/4
M A
X
SECURE WALL
CONSTRUCTION (REFER TO
PARTITION TYPES) 14 GA. COLD ROLLED STEEL
TELESCOPING FRAME FRAME
COLD ROLLED STEEL
DOOR
SOUND DEADENING
MATERIAL IN JAMB
DN
DN
UP
UP
UP
UP
ELEV.
SHAFT1HR
ABANDONED
STAIR 1HR
ELEV.
SHAFT1HR
FREIGHT
ELEV.1HR
EXIT
STAIR1HR
EXIT
STAIR1HR
SHAFT
1HR
LOBBY
1HR
ENTRY
LOBBY1HR
STAIR
1HR
COURTROOM
1HR
3 3a
33 3
3 3
3a
3 3 3
3 3
3 3
3a
3a
3 3 3
3 3
3 3
3 3 3
3 3 3
3a
3a
3a3a
3a 3a
3a
3a
C.5
RENOVATION
SHEET SIZE: 34 X 44
DRAWING NO.
CHECKED BY
DRAWN BY
FLOOR NO.
FILE NAME
DRAWING TITLE
SUB. DATE
SUBMISSION
GSA PM
PROJECT NO.
PROJECT
DESCRIPTION
PROJECT
TITLE
FACILITY CODE
OTHER
BUILDING NOs.
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
CONSTR. FIRM
SUB A/E
PRIME A/E
A/E CON. NO.
D R
A W
IN
G
P R
O J E
C T
B U
IL
D
IN
G
C O
N T
R A
C T
O R
S G
R A
P H
IC
S C
A L
E R
E V
IS
IO
N N
O T
E S
C E
R T
IF
IC
A T
IO
N
S
MARK DATE DESCRIPTION
SHEET OF
NK BHANDARI ARCHITECTURE
C&S ENGINEERS
GS-07-P-16-UC-D-7008
K E
Y P
L A
N
CONTROLLED UNCLASSIFIED INFORMATION (CUI) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
DATE:
A
SUB A/E
CONSTR. CON. -
NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)
PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS
OTHER THAN A LICENSED ARCHITECT OR THE DESIGN
ENGINEER. INFORMATION ON THESE DRAWINGS FOR
GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY
DEEM NECESSARY.
COPYRIGHT 2024
N. K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.
1020 7th North Street, Suite 130 Liverpool, NY 13088
Phone Fax www.nkbpc.com
315.428.1177 315.428.9822
499 Col. Eileen Collins Blvd Syracuse, NY 13212
Phone www.cscos.com
315.455.2000
U.S. General Services Administration
15 HENRY STREET
BINGHAMTON, NY 13901
B
C
D
3 4 51
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
PROPERTY OF THE UNITED STATES GOVERNMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS
DOCUMENT TO UNAUTHORIZED RECIPIENTS IS
PROHIBITED
CUI
/2
/2
:3 :2
A
M
SCHEDULES AND DIAGRAMS
1ST FLOOR BUILD-OUT
DBH
KRS 07/16/2025
16320.XX.124
07/16/2025
17 48
FOR CONSTRUCTION
AE600
JASON LITZ
DOOR SCHEDULE
DOOR
NUMBER ROOM NAME
ROOM
NUMBER
DOOR FRAME
THRESHOLD
FIRE
RATING
STC
RATING REMARKS
HARDWARE
SET
DOOR
NUMBERWIDTH HEIGHT THICKNESS TYPE
DOOR
MATERIAL FINISH FRAME TYPE
FRAME
MATERIAL FRAME FINISH
FRAME
DETAIL
134B SERVICE CORRIDOR 134B 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 9 134B
137 ENTRY VESTIBULE 137 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - 50 1, 3, 9 3 137
139 OPEN OFFICE 144 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 1 4 139
140 ELEC. AND COMMS 140 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 T1 - 1, 5 6 140
141 LAN ROOM 141 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 T1 45 MIN. 1, 5 6 141
142 OFFICE 142 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 45 1, 2, 10 4 142
143 IT WHITE SPACE 143 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - 1, 5, 6, 7 1 143
144 OPEN OFFICE 144 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - 50 1, 4, 5, 6, 8 2 144
145 OFFICE 145 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 45 1, 10 10 145
146 OFFICE 146 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - 45 1,2 7 146
147 ADMIN. AREA 147 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - 1 5 147
148 FILING ROOM 148 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - 1 10 148
149 OFFICE 149 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 45 1, 2 7 149
150 CONF. ROOM 150 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 50 3 8 150
151 OFFICE 151 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 45 1, 2 7 151
152 EXISTING CORRIDOR 228 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 9 152
155 3' - 0" 6' - 0" 0' - 1 3/4" 155
161 BREAK ROOM 138 3' - 0" 7' - 0" 0' - 1 3/4" F WD TR-6 CAT POLY H1 HM PNT3 4 & 5/ AE600 - - 5 161
1/4" = 1'-0"AE600
1 DOOR FRAME TYPES
1/4" = 1'-0"AE600
2 DOOR TYPES
DOOR SCHEDULE REMARKS
NUMBER DOOR SCHEDULE REMARKS
1 ELECTRONIC SECURITY - REFER TO HARDWARE SETS AND SECURITY DRAWINGS
2 SOUND CONTROL DOOR & FRAME WITH STC RATING = STC 45
3 SOUND CONTROL DOOR & FRAME WITH STC RATING = STC 50
4 CERTIFIED SOUND CONTROL RATED DOOR AND FRAME WITH STC RATING = 50. SOUND
RATED DOOR MEETING SOUND GROUPS 3 AND 4 STANDARDS, THIS SOUND RATED DOOR
AND LOCK PACKAGE COMES WITH LOCKING DEVICE, ENTRY SIDE OF THIS DOOR INSTALLED
WITH LOCKMASTERS (OR APPROVED EQUAL) LOCK. EXIT SIDE OF THE DOOR INSTALLED
WITH A MATCHING DOOR LEVER. THE COMPLETE DOOR PACKAGE INCLUDES: COMPLETE
DOOR UNIT WITH FRAME, HINGES, DOOR CLOSER, LEVER, LOCKING DEVICE, BUILT IN
THRESHOLD, DOOR BOTTOM AND SECURE DOOR SEAL SYSTEM. INSTALLATION AND
TESTING WILL BE REQUIRED BY VENDOR.
5 INGRESS BY PRESENTING CREDENTIAL AT PROXIMITY READER OR BY KEY OVERRIDE.
AUXILIARY LATCH DEADLOCKS LATCHBOLT WHEN DOOR SHUT. EGRESS ALWAYS FREE.
6 LOCKING HARDWARE ON ALL DOOR ASSEMBLIES IN MEANS OF EGRESS LEADING TO EXITS
SHALL BE ARRANGED TO OPEN READILY FROM THE EGRESS SIDE. PROPOSED LOCKING
ARRANGEMENTS SHALL NOT REQUIRE THE USE OF A KEY, A TOOL, A CARD, OR SPECIAL
KNOWLEDGE, OR EFFORT FOR OPERATION FROM THE EGRESS SIDE. A RELEASING DEVICE
ON A DOOR LEAF SHALL HAVE AN OBVIOUS METHOD OF OPERATION FROM THE EGRESS
SIDE, AND SHALL OPEN THE DOOR WITH JUST ONE OBVIOUS, SIMPLE, SINGLE RELEASING
OPERATION BY ONE HAND UNDER ALL LIGHTING CONDITIONS [EXCEPT FOR SPECIAL
LOCKING DELAYED EGRESS AND SENSOR-RELEASE OF ELECTRICAL LOCKING SYSTEMS
ARRANGEMENTS (IF ANY) PROVIDED IN ACCORDANCE WITH 7.2.1.6 OF NFPA 101.
7 OPERATIONAL DESCRIPTION #1: DOOR NORMALLY CLOSED AND LOCKED.
DOOR UNLOCKED FROM EXTERIOR SIDE BY VALID PIV CREDENTIAL.
EGRESS PROVIDED WHEN DOOR IS RELEASED FROM INTERIOR BY LEVER.
ELECTRIC STRIKE WILL REMAIN LOCKED (FAIL SECURE) UPON LOSS OF POWER.
MECHNICAL KEY OVERRIDE FROM EXTERIOR.
FREE EGRESS FROM INSIDE AT ALL TIMES.
8 OPERATIONAL DESCRIPTION #2: DOOR NORMALLY CLOSED AND LOCKED.
DOOR UNLOCKED FROM EXTERIOR SIDE BY VALID PIV CREDENTIAL AND HIGH SECURITY
TUMBLER LOCK.
EGRESS PROVIDED WHEN DOOR IS RELEASED FROM INTERIOR BY LEVER.
ELECTRIC STRIKE WILL REMAIN LOCKED (FAIL SECURE) UPON LOSS OF POWER.
INTERIOR KEYPAD ARMS/DISARMS SECURITY SYSTEM LOCATED INSIDE PRIMARY DOOR.
MECHANICAL KEY OVERRIDE FROM EXTERIOR.
FREE EGRESS FROM INSIDE AT ALL TIMES.
9 OPERATIONAL DESCRIPTION #3: DOOR NORMALLY CLOSED AND LOCKED.
DOOR CANNOT BE ACCESSED FROM THE EXTERIOR. NO TRIM OR CYLINDER ON EXTERIOR.
EGRESS PROVIDED WHEN DOOR IS RELEASED FROM INTERIOR BY PUSH BAR.
DEPRESSING PUSH PAD WILL ACTIVATE LOCAL ALARM. OPENING DOOR WILL SEND SIGNAL
TO SECURITY CONTROL.
DOOR REMAINS LOCKED (FAIL SECURE) UPON LOSS OF POWER.
FREE EGRESS FROM INSIDE AT ALL TIMES.
10 PROVIDE NO PERIMETER SEAL, AUTOMATIC DOOR BOTTOM, OR CORNER BLOCKS ON DOOR
EVEN THOUGH IT IS AN STC RATED DOOR.
1/2" = 1'-0"AE600
4 DOOR SECURITY HARDWARE DIAGRAM
1 1/2" = 1'-0"AE600
5 DOOR HEAD DETAIL (GWB)
1 1/2" = 1'-0"AE600
6 DOOR JAMB DETAIL (GWB)
DOOR SCHEDULE NOTES
1 DOOR GEOMETRY: ALL DOORS TO BE 1 ¾” THICK X 84” HIGH UON. PROVIDE DOORS OF
MATERIAL, CONSTRUCTION, AND FINISH PER THE DRAWINGS AND SPECIFICATIONS.
2 UNDERCUT / CLEARANCES: ALL DOOR UNDERCUTS TO BE ¾” UON. ACTUAL CLEARANCE AT
THRESHOLD OF FIRE RATED DOORS IS TO BE PROVIDED PER THE TESTED AND LISTED
ASSEMBLY, ALLOWING FOR PROPER OPERATION AND PROPER ENGAGEMENT OF ALL
REQUIRED HARDWARE ON THE RATED OPENING.
3 DOOR AND FRAME DUTY: PROVIDE DOOR AND FRAMES OF THE APPROPRIATE DUTY AND
CONSTRUCTION AS SHOWN ON THE DRAWINGS AND AS SPECIFIED.
4 DOOR WIDTH CONVENTION: DOOR LEAF WIDTH IS INDICATED IN INCHES IN THE DOOR
SCHEDULE. TWO NUMBERS SEPARATED BY A FORWARD SLASH (/) INDICATES DOUBLE
DOORS.
5 FRAMES: ALL FRAMES TO BE OF MATERIAL, CONSTRUCTION, AND FINISH PER THE
DRAWINGS AND SPECIFICATIONS. PROVIDE FRAME ANCHOR TYPE TO SUIT WALL
CONSTRUCTION AND ANCHOR QUANTITY PER HMMA 840-14. ALL FRAMES TO OVERLAP
WALL FINISH UON.
6 FRAME CONSTRUCTION: HM FRAMES ARE TO BE MITERED AND FULLY WELDED UON.
KNOCK DOWN FRAMES WILL THE INDICATED ON THE DRAWINGS AND IN THE
SPECIFRICATIONS IF THEY ARE TO BE USED.
7 DOOR AND FRAME FIRE RATING: WHERE FIRE RATED DOORS ARE INDICATED, DOOR FRAME
RATING SHALL EQUAL THE DOOR RATING. BORROWED LIGHT FRAMES FOR WINDOWS
INSTALLED IN FIRE RATED PARTITIONS TO BE RATED SAME AS DOOR FRAMES AND BE
COMPATIBLE WITH WALL TYPE.
8 FIRE DOOR ASSEMBLIES: FIRE DOOR ASSEMBLIES SHALL COMPLY WITH NFPA 80 STANDARD
FOR FIRE DOORS AND OTHER OPENING PROTECTIVES. FIRE RATED OPENINGS SHALL BE
TESTED AND OR LISTED BY ONE OF THE FOLLOWING THREE AGENCIES: 1) UNDERWRITERS
LABORATORIES, 2) INTERTEK / WARNOCK HERSEY MARK, OR 3) FACTORY MUTUAL. FIRE
RATING LABELS ARE TO BE AS FOLLOWS:
A LABEL = 3 HOURS (180 MIN)
B LABEL = 1 ½ HOURS (90 MIN)
C LABEL = ¾ HOUR (45 MIN)
9 GLAZING: ALL VISION PANELS IN FIRE RATED DOORS AND FRAMES TO BE OF GLAZING TYPE
AND THICKNESS AS SHOWN ON THE DRAWINGS AND IN THE SPECIFICATIONS. ALL VISION
PANELS IN NON-RATED DOORS AND FRAMES TO BE SAFETY GLASS UON. ALL EXTERIOR
DOOR LIGHTS, TRANSOMS, AND SIDELIGHTS TO BE 1” INSULATING TEMPERED GLASS UON.
10 HARDWARE REINFORCEMENT: DOORS AND FRAMES SHALL BE REINFORCED FOR
INSTALLATION OF ALL HARDWARE. DRILLING AND TAPPING FOR ATTACHING OF SURAFCE
MOUNTED HARDWARE TO BE PROVIDED FOR COMPLETE FUNCTIONAL DOOR OPENING.
11 DOOR POSITION: FINISHED DOOR OPENINGS SHALL BE NOMINAL 6” FROM FINISHED CORNER
OF ROOM AT HINGE SIDE, EXCEPT WHERE DIMENSIONED OTHERWISE. ON THE “PULL” SIDE
OF A DOOR OPENING, THE STRIKE SIDE SHALL BE NOMINAL 18” FROM A PERPENDICULAR
WALL. ON THE “PUSH” SIDE OF A DOOR OPENING EQUIPPED WITH BOTH A CLOSER AND
LATCH, THE STRIKE SIDE SHALL BE NOMINAL 12” FROM A PERPENDICULAR WALL.
0 2' 4' 8'
0 1' 2'
0 1' 2' 0 2' 4' 8'
0 1' 2' 4'
1 1/2" = 1'-0"AE600
7 DOOR HEAD DETAIL (GWB)
0 1' 2'
0 1' 2'
DOOR SCHEDULE NOTES
12 MASONRY OPENING LINTELS: ALL MASONRY OPENINGS TO RECEIVE LINTELS. REFER TO
LINTEL SCHEDULE FOR MORE INFORMATION.
13 GROUTING OF FRAMES IN MASONRY: WHEN FRAMES ARE IN MASONRY CONSTRUCTION TO
BE FILLED WITH GROUT AND ANTI-FREEZE AGENTS ARE PRESENT, THE INSIDES OF THE
FRAMES SHALL BE TREATED BY THE GENERAL CONTRACTOR WITH A SUITABLE BITUMINOUS
UNDERCOATING MATERIAL AS SPECIFIED.
14 FRAME BOX-OUTS: PROVIDE BOX-OUTS (MORTAR BOXES, STRIKE BOXES, ACCESS
CONTROL HARDWARE, ETC.) IN DOOR FRAMES WHERE FRAMES ARE GROUTED OR IN
MASONRY WALL.
15 JAMB AND HEAD STUDS: AT METAL STUD WALLS (GYPSUM BOARD WALLS), PROVIDE 20 GA
METAL STUDS AT JAMBS AND HEADS OF DOOR OPENINGS UON.
16 EXTERIOR DOORS AND FRAMES (WHERE SHOWN): ALL EXTERIOR HOLLOW METAL DOORS
AND FRAMES SHALL BE PROVIDED UTILIZING METALLIC-COATED STEEL (GALVANIZED)
STEEL SHEETS AS SPECIFIED.
17 PRE-TREAMENT AND PRIME PAINT: ALL HOLLOW METAL DOORS AND FRAMES SHALL
RECEIVE AN IRON PHOSPHATE PRE-TREATMENT AND ONE COAT OF BAKED ON PRIME
PAINT.
18 EXISTING OPENING COMPONENTS: WHERE AN EXISTING OPENING COMPONENT (DOOR,
FRAME, HARDWARE) IS TO BE RE-USED, EACH COMPONENT SHALL BE INDICATED AS “EX” IN
THE SCHEDULE, DENOTING “EXISTING”. ALL EXISTING COMPONENTS ARE TO BE INSPECTED
IN THE FIELD, VERIFY 1) DIMENSIONAL CHARACTERESTICS, 2) MOUNTING HEIGHTS /
GEOMETRIES, 3) MANUFACTURER / MODEL INFORMNATION, and 4) FIRE RATED LABEL OR
LISTING INFORMATION AVAILABLE FOR EACH COMPONENT.
19 ACCESS CONTROL RACEWAYS: PROVIDE ALL RACEWAYS REQUIRED FOR THE COMPLETE
INSTALLATION AND PROPER OPERATION OF ALL SCHEDULED ACCESS CONTROL
HARDWARE. REFER TO DOOR AND HARDWARE SCHEDULES, ACCESS CONTROL DRAWINGS,
AND RELATED SPECIFICATIONS FOR MORE INFORMATION.
20 OPERATIONAL DESCRIPTION: DOOR ACCESS CONTROL OPERATIONAL DESCRIPTION TO BE
AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS. CONFIRM OPERATIONAL
DESCRIPTION / SEQUENCE THROUGH SUBMITTAL AND REVIEW PROCESS WITH ARCHITECT /
OWNER.
21 STORAGE OF DOORS AND FRAMES: STORE DOORS AND FRAMES AT THE PROJECT UNDER
COVER AS SPECIFIED. PLACE UNITS ON AT LEAST 4” WOOD SILLS OR ON FLOOR IN A
MANNER THAT WILL PREVENT RUST AND DAMAGE. AVOID USE OF NON-VENTED PLASTIC OR
CANVAS SHELTERS, WHICH CREATE A HUMIDITY CHAMBER. IF THE WRAPPER ON ANY
COMPONENT BECOMES WET, REMOVE IMMEDIATELY, PROVIDE ¼” SPACE BETWEEN DOORS
AND FRAMES TO PROMOTE CIRCULATION. ADDITIONAL STORAGE INFORMATION PER ANSI
A250.8 (SDI100) IS RECOMMENDED.
22 ONCE INSTALLED, CONTRACTOR SHALL ENSURE THAT THE GAP BETWEEN DOORS AND
FRAMES IS CONSISTENTLY WITHIN MANUFACUTER STANDARDS (TYPICALLY 1/8") FOR
PROPER FUNCTIONALITY WITH SCHEDULED SECURITY / LOCKING MECHANISM AND
ACOUSTICAL GASKETS.
F-RF
F-A
F-A
F-A
F-A
F-RF
F-A
45 MIN.
DOOR HARDWARE SCHEDULE
1/2" = 1'-0"AE600
9 ICD 705 DOOR SECURITY HARDWARE DIAGRAM
0 1' 2' 4'
F WD TR-6 CAT POLY H1 HM PNT3
- 11
1 1/2" = 1'-0"AE600
8 DOOR JAMB DETAIL 2 (GWB)
CATWALK ---
5 & 6/ AE600
5 & 6/ AE600
5 & 6/ AE600
7 & 8/ AE600
7 & 8/ AE600
7 & 8/ AE600
7 & 8/ AE600
7 & 8/ AE600
7 & 8/ AE600
7 & 8/ AE600
7 & 8/ AE600
5 & 6/ AE600
5 & 6/ AE600
5 & 6/ AE600
5 & 6/ AE600
5 & 6/ AE600
5 & 6/ AE600
5 & 6/ AE600
1 04/24/26 Door Hardware Schedule
File details come from the government source that posted it. Updated .