47PC0222R0019 Solicitation _ Exhibit 4 Revised Pricing Proposal Sheet - Caribbean Construction IDIQ 5-11-2023.xlsx

XLSX spreadsheet 38 KB Posted

Attached to
GSA R2 - Caribbean Construction IDIQ
Solicitation number
47PC0222R0019
Issued by

View the file

Other files

File Type Posted
Solicitation Amendment 47PC0222R0019_0003-SF30.pdf PDF
Solicitation 47PC0222R0019 Amendment_0003.pdf PDF
Solicitation 47PC0222R0019 - Exhibit 16 Presentation Pre-Proposal Conference.pdf PDF
Solicitation 47PC0222R0019 - Exhibit 15 Amendment 0003 - GSA RFIs Response.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 3 - SF-1442 5-24-23.pdf PDF
47PC0222R0019 Solicitation _ Revised 5-14-2023.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 3 - SF-1442 5-16-2023.pdf PDF
Solicitation Amendment 47PC0222R0019_0002.pdf PDF
Pre-Proposal Conferences_ Flyer.pdf PDF
Solicitation Amendment 47PC0222R0019_0001.pdf PDF
47PC0222R0019 Generated PDF with TOC.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 5 - Experience on Similar Projects Offeror Form - Final.xlsx XLSX spreadsheet
47PC0222R0019 Solicitation _ Exhibit 10 - SOW_ GSA Standard Division One Specifications.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 4 Pricing Proposal Sheet - Caribbean Construction IDIQ 3-1-2023.xlsx XLSX spreadsheet
47PC0222R0019 Solicitation _ Exhibit 13 Wage Determination PR20230001 01-06-2023.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 3 - SF-1442.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 8 - Statement of Work - Caribbean Construction IDIQ (final).pdf PDF
47PC0222R0019 Solicitation _ Final.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 9 - SOW_ Place of Performance and Building Locations - Caribbean.pdf PDF
47PC0222R0019 Solicitation _ Solicitation Submission Checklist.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 2 - GC Reps and Certs Final.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 12 - SOW_ Task Order Price Template Final.xlsx XLSX spreadsheet
47PC0222R0019 Solicitation _ Exhibit 7 - Past Performance Questionnaire.docx DOCX document
47PC0222R0019 Solicitation _ Exhibit 1 - Agreement Final.pdf PDF
47PC0222R0019 Solicitation _ Exhibit 6 - Key Personnel Qualifications Resume Form - Update.xlsx XLSX spreadsheet
47PC0222R0019 Solicitation _ Exhibit 11 - SOW_ Task Order Award Procedures Final.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pricing Sheet

Caribbean Construction IDIQ - Revised Price Proposal Sheet RFP # 47PC0222R0019 EXHIBIT 4 - 5/11/2023
General Contractor Rate for Material and LaborGeneral Contractor Rate for Material and LaborGeneral Contractor Rate for Material and LaborGeneral Contractor Rate for Material and LaborGeneral Contractor Rate for Material and Labor
1IDDescriptionUnitBase Year1st Option Year2nd Option Year3rd Option Year4th Option Year
2Rate|PMProject Manager hourly rateHR
3Rate|CQMQuality Control Manager hourly rateHR
4Rate|Safety MgrSafety Manager hourly rateHR
5Rate|SuperSuperintendent hourly rateHR
624 hour RateEmergency Remediation - Project DirectorHR
724 hour RateEmergency Remediation - Certified Remediation TechnicianHR
824 hour RateEmergency Remediation - Project ManagerHR
924 hour RateEmergency Remediation - Project/Restoration SupervisorHR
1024 hour RateEmergency Remediation - Project AuditorHR
1124 hour RateEmergency Remediation - Restoration TechnicianHR
1224 hour RateEmergency Remediation - Health and Safety OfficerHR
13Rate|Clab1 Common Laborer hourly rateHR
14Rate|Carp1 Carpenter hourly rateHR
15Rate|Elec1 Electrician hourly rateHR
16Rate|Plum1 Plumber hourly rateHR
1702411 919 2000Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition costC.Y.
1802821 339 0100Asbestos remediation, plans and methods, building survey, commercialEa.
1902821 342 0100Preparation of asbestos containment area, pre-cleaning, HEPA vacuum and wet wipe, flat surfacesS.F.
2002821 342 0200Preparation of asbestos containment area, protect carpeted area, 2 layers 6 mil poly on 3/4" plywoodS.F.
2102821 342 0300Preparation of asbestos containment area, separation barrier, 2" x 4" @ 16", 1/2" plywood each side, 8' highS.F.
2202821 342 0550Preparation of asbestos containment area, cover surfaces with polyethylene sheeting, floors, each layer, 6 mil, incl. glue & tapeS.F.
2302821 346 0200Decontamination of asbestos containment area, spray exposed substrate with surfactant (bridging), flat surfacesS.F.
2402821 346 4100Decontamination of asbestos containment area, remove portable decontamination facilityEa.
2503013 062 0100Patching concrete, floors, small area, regular grout, 1/4" thickS.F.
2603354 310 0110Polished concrete floors, processing of interior floors, removal of glue, adhesive or tar, includes dry grinding with planetary floor grinder, dry vac pick-up, hand sweepingM.S.F.
2703821 310 0500Concrete core drilling, core, reinforced concrete slab, 4" diameter, up to 6" thick slab, includes bit cost, layout and set up timeEa.
2803821 310 0550Concrete core drilling, core, reinforced concrete slab, 4" diameter, up to 6" thick slab, includes bit cost, layout and set up time, for each additional inch of slab thickness in same hole, addEa.
2904050 510 0420Selective demolition, masonry, concrete block walls, reinforced alternate courses, 10" thickS.F.
3005411 330 4340Partition, galvanized LB studs, 16 ga x 3-5/8" W studs 16" OC x 8' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridgingL.F.
3106050 520 1220Selective demolition, millwork and trim, casework, selective area, removeS.F.
3206221 315 5215Moldings, base, ogee profile, 9/16" x 4-1/2", red oakL.F.
3306221 345 0900Moldings, trim, chair rail, stock pine, 3-1/2" x 5/8" thickL.F.
3407211 620 0020Blanket insulation, for walls or ceilings, kraft faced fiberglass, 3-1/2" thick, R11, 15" wideS.F.
3507211 620 0160Blanket insulation, for walls or ceilings, kraft faced fiberglass, 6" thick, R19, 15" wideS.F.
3607211 620 1320Blanket insulation, for walls or ceilings, mineral wool batts, 3-1/2" thick, R15S.F.
3708050 510 0200Door demolition, exterior door, single, 3' x 7' high, 1-3/4" thick, removeEa.
3808050 510 0220Door demolition, exterior door, double, 6' x 7' high, 1-3/4" thick, removeEa.
3908050 510 0500Door demolition, interior door, single, 3' x 7' high, 1-3/8" thick, removeEa.
4008050 510 2000Door demolition, door frames, metal, removeEa.
4108050 510 2205Door demolition, door hardware, removeEa.
4208050 510 3300Door demolition, special doors, sliding glass, removeEa.
4308050 520 0600Window demolition, glass, up to 10 S.F. per windowS.F.
4408121 313 7900Frames, hollow metal, transom lite frames, fixed, addS.F.
4508121 320 0460Frames, steel, wrap around, 16 ga., 6-1/4" x 7'-0" x 3'-0" wideEa.
4608121 320 0580Frames, steel, wrap around, 16 ga., 6-1/4" x 7'-0" x 6'-0" wideEa.
4708131 313 0100Doors, hollow metal, commercial, steel, flush, full panel, hollow core, 1-3/8" thick, 20 ga., 3'-0" x 7'-0"Ea.
4808131 313 1760Doors, commercial, steel, insulated, full panel, 18 ga., 3'-0" x 7'-0" x 1-3/4" thickEa.
4908131 313 2000For vision lite, addEa.
5008131 325 3160Doors, fire, "B" label, exterior, steel, commercial, flush, 1-3/4" x 7'-0" x 3'-0" wideEa.
5108131 610 5050Doors, aluminum, commercial entrance, flush panel doors, single, 3'-0" x 7'-0", incl. hinges, push/pull, deadlock, cylinder, threshold, excl. glazingEa.
5208141 620 0790Doors, wood, fire, particle core, 7 face plies, "B" label, 90 minutes, birch face, 1-3/4" x 3'-0" x 7'-0"Ea.
5308311 310 6100Doors, specialty, access, standard, metal, 8" x 8"Ea.
5408311 310 6150Doors, specialty, access, standard, metal, 12" x 12"Ea.
5508311 310 6200Doors, specialty, access, standard, metal, 18" x 18"Ea.
5608311 310 6250Doors, specialty, access, standard, metal, 24" x 24"Ea.
5708311 310 6300Doors, specialty, access, standard, metal, 24" x 36"Ea.
5808311 310 6350Doors, specialty, access, standard, metal, 36" x 36"Ea.
5908321 310 5010Doors, aluminum sliding glass door system, 4' wide opening single side, 4'x7'Ea.
6008712 010 0020Door hardware, bolts, flush, standard, concealedEa.
6108712 030 0020Door hardware, door closer, rack and pinion, adjustable backcheck, 3 way mount, all sizes, regular armEa.
6208712 030 0040Door hardware, door closer, rack and pinion, adjustable backcheck, 3 way mount, hold open armEa.
6308712 030 1525Door hardware, door closer, rack and pinion, backcheck, overhead concealed, all sizes, concealed armEa.
6408712 036 0550Door hardware, panic device, for rim locks, single door, standard duty, touch bar narrow stile, US28Ea.
6508712 036 1060Door hardware, panic device, rim locks, single door, touch bar, wide style, standard duty, surface vertical vod, US28Ea.
6608712 040 4030Door hardware, lockset, keyless, pushbutton type, industrial, heavy duty, with deadbolt, key overrideEa.
6708712 042 0100Door hardware, mortise lockset, commercial, wrought knobs and full escutcheon trim, keyed, office/entrance/apartment, grade 2Ea.
6808712 050 0020Door hardware, doorstops, holder and bumper, floor or wallEa.
6908712 065 0100Thresholds, aluminum, 8" wide x 1/2" thickEa.
7008712 065 2410Threshold, aluminum, ADA, 7" wide x 72" longEa.
7108712 090 8000Door hardware, hinge, installPr.
7208712 110 0400Astragals, one piece overlapping, cadmium plated steel, flat, 3/16" x 2"L.F.
7308812 010 0020Glass, full vision window system, 3/4" glass mullions, 10' highS.F.
7408816 510 1000Wire glass, polished wire, diamond, clear, 1/4" thickS.F.
7509017 010 0140Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, up to 2" squareEa.
7609017 010 0150Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 2" to 4" squareEa.
7709017 010 0160Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 4" to 8" squareEa.
7809017 010 0170Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 8" to 12" squareEa.
7909017 010 0180Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 12" to 32" squareEa.
8009017 010 0210Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 16" by 48"Ea.
8109017 010 0220Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 32" by 48"Ea.
8209017 010 0230Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 48" squareEa.
8309017 010 0240Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 60" squareEa.
8409017 010 0500Gypsum wallboard, repairs, skim coat surface with joint compoundS.F.
8509050 510 1200Ceiling demolition, suspended ceiling, mineral fiber, 2 x 2 or 2 x 4, removeS.F.
8609050 510 1250Ceiling demolition, suspended ceiling, mineral fiber, on suspension system, removeS.F.
8709050 520 0400Flooring demolition, carpet, bonded, includes surface scrapingS.F.
8809050 520 0480Flooring demolition, custom carpet, heavy, tackless, remove and reset, includes surface scrapingS.F.
8909050 520 0550Carpet tile, releasable adhesive, removalS.F.
9009050 520 0800Flooring demolition, resilient, sheet goodsS.F.
9109050 520 0850Flooring demolition, vinyl or rubber cove base, straight sectionL.F.
9209050 520 0900Flooring demolition, vinyl composition tile, 12" x 12"S.F.
9309050 520 2000Flooring demolition, tile, ceramic, thin setS.F.
9409050 520 8200Flooring demolition, raised access floorS.F.
9509050 530 0020Walls and partitions demolition, concrete, reinforcedC.F.
9609050 530 0200Walls and partitions demolition, concrete block, 4" thickS.F.
9709050 530 0280Walls and partitions demolition, concrete block, 8" thick, remove damaged blocksS.F.
9809050 530 1000Walls and partitions demolition, gypsum wallboard, per s.f., nailed or screwedS.F.
9909050 530 2300Walls and partitions demolition, metal or wood studs, finish two sides, plasterboard (gypsum wallboard)S.F.
10009050 530 3760Walls and partitions demolition, tile, ceramic, on walls, thin setS.F.
10109050 530 3975Selective demolition, demolish wire mesh panelsS.F.
10209050 530 5000Walls and partitions demolition, wallcovering, vinylS.F.
10309050 530 5010Walls and partitions demolition, wallcovering, vinyl, with release agentS.F.
10409221 313 1200Furring, walls, on steel, galvanized, 7/8" channels, 16" OCS.F.
10509221 613 1640Metal stud partition, non-load bearing, galvanized, 8' high, 3-5/8" wide, 25 gauge, 16" OC, includes top & bottom trackS.F.
10609223 643 0100Security mesh, expanded metal, flat, screwed to framing, on walls, 3/4", 1.76 lb/SFS.F.
10709232 010 0300Gypsum plaster, 2 coats, on walls, lath excludedS.Y.
10809291 030 0300Gypsum wallboard, on walls, standard, 1/2" thick, finish excludedS.F.
10909291 030 0390Gypsum wallboard, on walls, standard, w/compound skim coat (level 5 finish), 1/2" thickS.F.
11009291 030 2150Gypsum wallboard, on walls, fire resistant, taped & finished (level 4 finish), 5/8" thickS.F.
11109512 310 1110Suspended acoustic ceiling tiles, mineral fiber tile, lay-in, fine texture, 2' x 2' or 2' x 4', 5/8" thickS.F.
11209512 310 1125Suspended acoustic ceiling tiles, mineral fiber tile, lay-in, fine texture, 2' x 2' or 2' x 4', 3/4" thickS.F.
11309512 310 1135Suspended acoustic ceiling tiles, mineral fiber tile, lay-in, fissured, 2' x 2' or 2' x 4', 3/4" thickS.F.
11409512 310 1190Suspended acoustic ceiling tiles, for fire rating, addS.F.
11509512 330 0800Complete suspended ceilings, mineral fiber, lay-in board, 2' x 2' x 3/4", on 15/16" T bar suspension, include standard suspension system, excl. 1-1/2" carrier channelsS.F.
11609512 330 0810Complete suspended ceilings, mineral fiber, lay-in board, 2' x 4' x 5/8", on 15/16" T bar suspension, include standard suspension system, excl. 1-1/2" carrier channelsS.F.
11709641 910 0300Wood composition flooring, for sanding and finishing, addS.F.
11809651 313 0700Wall base, vinyl, straight or cove, standard colors, 4" high, 1/8" thickL.F.
11909651 313 0710Wall base, vinyl, straight or cove, standard colors, 6" high, 1/8" thickL.F.
12009651 313 1100Wall base, rubber, straight or cove, standard colors, 4" high, 1/8" thickL.F.
12109651 919 7000Flooring, vinyl composition tile, 12" x 12" x 1/16"S.F.
12209680 511 0107Carpet transition strip, clamp down brass divider 12'/each (@vinyl to carpet)Ea.
12309681 010 9000Carpet, 20 oz./sq. yd., for tackless, stretched installation, add padding to above, sponge rubber padS.Y.
12409681 010 9300Carpet pad, 32-56 oz./sq. yd., for tackless, stretched installation, add padding to above, feltS.Y.
12509681 010 9800Carpet pad, for 'double stick' installation, addS.Y.
12609681 310 1100Carpet tile, tufted nylon, 24 oz., 18" x 18" or 24" x 24"S.Y.
12709681 310 1180Carpet tile, tufted nylon, 35 oz., 18" x 18" or 24" x 24"S.Y.
12809681 610 0700Carpet, commercial grades, direct cement, nylon, level loop, 26 oz., light to medium trafficS.Y.
12909681 610 0720Carpet, commercial grades, direct cement, nylon, level loop, 28 oz., light to medium trafficS.Y.
13009681 610 1100Carpet, commercial grades, direct cement, nylon, level loop, 40 oz., medium to heavy trafficS.Y.
13109681 610 3100Carpet, commercial grades, direct cement, nylon, plush, 42 oz., medium to heavy trafficS.Y.
13209681 610 3300Carpet, commercial grades, direct cement, nylon, plush, 54 oz., heavy trafficS.Y.
13309681 610 3340Carpet, commercial grades, direct cement, nylon, plush, 60 oz., heavy trafficS.Y.
13409681 610 5600Carpet, for bound carpet baseboard, addL.F.
13509691 310 0250Access floors, concrete fill panels, 2'x2', no finishS.F.
13609721 613 3400Wall coverings, vinyl, fabric-backed, heavyweight, type 3 (28 oz./S.Y.), incl. sizingS.F.
13709721 910 0050Textile wall coverings, blend, incl. sizingS.F.
13809019 092 0510Paint preparation, surface protection, placement & removal, basic drop clothsS.F.
13909019 094 0080Surface preparation, interior, doors, wire brush, metal, flushS.F.
14009911 342 0330Paints & coatings, misc. exterior, stair stringers, exterior, rough sawn wood, roll & brush, exterior latex, each coat, 4" x 12"L.F.
14109911 370 0135Paints & coatings, exterior door frames & trim only, brushwork, 2 coats, exterior latex, both sidesEa.
14209911 370 0190Paints & coatings, exterior doors, flush, both sides, roll & brush, primer + 2 coats, exterior latex, incl. frame & trimEa.
14309912 333 1200Paints & coatings, interior, alkyd (oil base), flush door w/frame, 2 coats, brushwork, 3' x 7'Ea.
14409912 333 1400Paints & coatings, interior, alkyd (oil base), doors, flush, w/frame, both sides, stain, brushwork, wipe off, 3' x 7', excl. frameEa.
14509912 333 1800Paints & coatings, interior, doors, flush, w/frame, both sides, varnish, brushwork, sand after 1st coat, 3' x 7', excl. frameEa.
14609912 335 0130Paints & coatings, interior latex, doors, flush, both sides, roll & brush, primer + 1 coat, incl. frame & trimEa.
14709912 335 0510Paints & coatings, interior latex, windows, per interior side, 1-6 lite, brushwork, primer + 2 coats, enamel, based on 15 SFEa.
14809912 352 6600Paints & coatings, miscellaneous interior, radiators, per side, primer, brushworkS.F.
14909912 352 7600Paints & coatings, miscellaneous interior, trim, wood, paint 2 coats, oil base, brushwork, over 6" wideL.F.
15009912 362 0400Electrostatic painting, flat surfaces (lockers, casework, elevator doors, etc.), two coats, in shopS.F.
15109912 372 0800Paints & coatings, walls & ceilings, interior, concrete, drywall or plaster, latex paint, 2 coats, smooth finish, brushworkS.F.
15209912 372 0880Paints & coatings, walls & ceilings, interior, concrete, drywall or plaster, latex paint, 2 coats, smooth finish, sprayS.F.
15309912 374 0840Paints & coatings, walls & ceilings, interior, concrete, drywall or plaster, zero voc latex, 2 coats, smooth finish, rollerS.F.
15409912 374 8200Paints & coatings, walls & ceilings, interior, zero voc latex, for work 8'-15' high, addS.F.
15509932 310 0020Paints & coatings, varnish 1 coat + sealer, on wood trim, brush, incl. no sanding, no VOCS.F.
15610144 310 0111Photoluminescent exit sign, directional, plastic, 10"x14"Ea.
15710221 943 1200Partitions, movable office, demountable gypsum system, vinyl-clad, 2" - 2-1/2" steel studs, 9' h x 3"- 3-3/4" thick, excludes doors; do not deduct door openings from total LFL.F.
15810572 319 1000Wood shelving, bookcase, clear grade pine, 12" deep, shelves 12" OCS.F.
15912050 510 7400Selective demolition, office furniture systemsS.F.
16021131 350 5620Sprinkler system components, sprinkler heads, concealed, complete with coverplate, 135-212 degrees F, 1/2" NPT, 1/2" orifice, excludes supply pipingEa.
16122050 510 0720Fixture, water closet, selective demolitionEa.
16222050 510 1420Fixture, water closet, wall mounted, selective demolitionEa.
16322050 510 1600Fixture, water fountain, free standing, remove, includes 10' pipingEa.
16422050 510 2000Pipe, metal pipe, to 1-1/2" diam., selective demolitionL.F.
16522050 510 2050Pipe, metal pipe, 2" to 3-1/2" diam., selective demolitionL.F.
16622050 510 2100Pipe, metal pipe, 4" to 6" diam., selective demolitionL.F.
16722050 510 9300Vent flashing or vent caps, selective demolitionEa.
16822052 360 3240Valves, plastic, PVC, ball check, socket or threaded, 1/2"Ea.
16922052 360 3250Valves, plastic, PVC, ball check, socket or threaded, 3/4"Ea.
17022052 360 3260Valves, plastic, PVC, ball check, socket or threaded, 1"Ea.
17122052 360 3270Valves, plastic, PVC, ball check, socket or threaded, 1-1/4"Ea.
17222052 360 3280Valves, plastic, PVC, ball check, socket or threaded, 1-1/2"Ea.
17322052 360 3290Valves, plastic, PVC, ball check, socket or threaded, 2"Ea.
17422071 910 6860Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 3/4" iron pipe sizeL.F.
17522071 910 6870Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 1" iron pipe sizeL.F.
17622071 910 6880Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 1-1/4" iron pipe sizeL.F.
17722071 910 6890Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 1-1/2" iron pipe sizeL.F.
17822071 910 6900Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 2" iron pipe sizeL.F.
17922071 910 8445Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 3/4" iron pipe sizeL.F.
18022071 910 8446Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1" iron pipe sizeL.F.
18122071 910 8447Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1-1/4" iron pipe sizeL.F.
18222071 910 8448Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1-1/2" iron pipe sizeL.F.
18322071 910 8449Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 2" iron pipe sizeL.F.
18422111 323 1140Pipe, copper, tubing, solder, 1/2" diameter, type K, includes coupling & clevis hanger assembly 10' OCL.F.
18522111 323 1180Pipe, copper, tubing, solder, 3/4" diameter, type K, includes coupling & clevis hanger assembly 10' OCL.F.
18622111 323 1200Pipe, copper, tubing, solder, 1" diameter, type K, includes coupling & clevis hanger assembly 10' OCL.F.
18722111 323 1220Pipe, copper, tubing, solder, 1-1/4" diameter, type K, includes coupling & clevis hanger assembly 10' OCL.F.
18822111 348 1080Pipe, fittings & valves, steel, black, grooved joint, 2" diameter, schedule 40, incl coupling & clevis type hanger 10' OCL.F.
18922111 914 3440Flexible metal hose, metal stainless steel braid, over corrugated stainless steel flanged ends, 150 psi, 1-1/2" diameter x 12"Ea.
19022131 620 4100Pipe, cast iron soil, no hub, 1-1/2" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OCL.F.
19122131 620 4120Pipe, cast iron soil, no hub, 2" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OCL.F.
19222131 620 4140Pipe, cast iron soil, no hub, 3" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OCL.F.
19322131 620 4160Pipe, cast iron soil, no hub, 4" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OCL.F.
19422131 630 8340Coupling (by MG), cast iron soil, no hub, cast iron clamp and neoprene gasket, 4"Ea.
19522131 660 1150Traps, cast iron, service weight, running P trap, 4", excluding ventEa.
19622131 660 3000Traps, cast iron, service weight, P trap, B&S, 2" pipe sizeEa.
19722411 344 0150Toilet seat, molded composition, white, industrial, open front, regular bowl, excludes coverEa.
19822411 344 0520Toilet seat, molded composition, white, self-raising hinge, open front, regular bowl, excludes coverEa.
19922411 613 6060Lavatory, wall hung, porcelain enamel on cast iron, white, single bowl, 19" x 17", includes trimEa.
20022411 613 6960Lavatory, wall hung, rough-in, supply, waste and ventEa.
20122413 910 8200Faucets/fittings, water supply stops, polished chrome plate, angle, 3/8"Ea.
20222421 313 3200Water closet, bowl only, wall hung, includes auto sensor flush valve and seatEa.
20322421 313 3350Water closet, bowl only, floor mounted, tankless, with wall outlet, includes flush valve and seatEa.
20422421 313 3370Water closet, bowl only, floor mounted, tankless, rough-in, supply, waste and ventEa.
20522423 910 0900Faucets/fittings, flush valve, tankless water closet, concealed rear spud, wall hungEa.
20622423 910 0972Faucets/fittings, flush valve, automatic flush sensor and operator for urinals or waterclosets, standardEa.
20722423 910 2800Faucets/fittings, lavatory faucet, self-closing center set, commercialEa.
20822423 910 2810Faucets/fittings, lavatory faucet, automatic sensor and operator, with faucet head, commercialEa.
20922423 910 3000Faucets/fittings, service sink faucet, cast spout, pail hook, hose endEa.
21022423 930 4800Carriers/supports, sink, floor mounted, exposed arm system, back to back standard fixturesEa.
21122423 930 7040Carriers/supports, water closet, siphon jet, horizontal, adjustable, caulk, single, 4" pipe sizeEa.
21222471 310 2820Drinking fountain, wall mounted, non-recessed, stainless steel, dual level, ADA compliant, single bubbler, for connection to cold water supplyEa.
21323071 310 3160Duct thermal insulation, blanket type, fiberglass, flexible, FSK vapor barrier wrap, .75 lb. density, 1" thickS.F.
21423071 310 3180Duct thermal insulation, blanket type, fiberglass, flexible, FSK vapor barrier wrap, .75 lb. density, 2" thickS.F.
21523092 310 5010Control components/DDC system, communications bus (data transmission cable), #18 twisted shielded pair in 1/2" EMT conduitC.L.F.
21623095 310 5230Control component, thermostats, electric, low voltage, 3 wireEa.
21723095 310 5320Control component, transmitter, pneumatic, temperature averaging elementEa.
21823311 313 0500Metal ductwork, fabricated rectangular, galvanized steel, under 200 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulationLb.
21923311 313 0520Metal ductwork, fabricated rectangular, galvanized steel, 200 to 500 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulationLb.
22023311 313 0540Metal ductwork, fabricated rectangular, galvanized steel, 500 to 1000 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulationLb.
22123311 313 0560Metal ductwork, fabricated rectangular, galvanized steel, 1000 to 2000 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulationLb.
22223311 319 2000Duct accessories, fabrics for flexible connections, with metal edgeL.F.
22323331 313 7522Duct accessories, variable volume modulating motorized damper, 12" x 16", includes electric motorEa.
22423331 316 3200Duct accessories, fire damper, curtain type, vertical, 24" x 12", UL label, 1-1/2 hour ratedEa.
22523334 610 1940Ductwork, flexible coated fiberglass fabric on corrosion resistant metal helix, insulated, P.E. jacket, 1" thick, 6" diameter, pressure to 12"(WG) UL-181L.F.
22623334 610 2000Ductwork, flexible coated fiberglass fabric on corrosion resistant metal helix, insulated, P.E. jacket, 1" thick, 9" diameter, pressure to 12"(WG) UL-181L.F.
22723334 610 2040Ductwork, flexible coated fiberglass fabric on corrosion resistant metal helix, insulated, P.E. jacket, 1" thick, 12" diameter, pressure to 12"(WG) UL-181L.F.
22823335 310 3344Insulation, ductwork, board type, fiberglass liner, FSK, 1-1/2 lb. density, 1" thickS.F.
22923335 310 3346Insulation, ductwork, board type, fiberglass liner, FSK, 1-1/2 lb. density, 2" thickS.F.
23023361 610 5510Duct accessories, mixing box, variable air volume, cool only, pneumatic pressure independent, 500 to 1,000 CFM, includes electric or pneumatic motorEa.
23123361 610 5530Duct accessories, mixing box, variable air volume, cool only, pneumatic pressure independent, 1,100 to 2,000 CFM, includes electric or pneumatic motorEa.
23223361 610 5550Duct accessories, mixing box, variable air volume, cool only, pneumatic pressure independent, 2,000 to 4,000 CFM, includes electric or pneumatic motorEa.
23323371 310 0500Diffuser, aluminum, ceiling, perforated, 24" x 24" lay-in panel size, 6" x 6", includes opposed blade damperEa.
23423371 310 0620Diffuser, aluminum, ceiling, perforated, 24" x 24" lay-in panel size, 24" x 24", includes opposed blade damperEa.
23523371 310 1560Diffuser, steel, ceiling, round, 12" diameter, includes butterfly damperEa.
23623371 330 0380Grille, aluminum, air supply, adjustable, single deflection, 24" x 24"Ea.
23723371 330 4040Grille, aluminum, eggcrate, framed, 24" x 24" openingEa.
23823371 360 4080Register, air supply, floor, enameled steel, 6" x 14", includes toe operated damperEa.
23926015 081 0962Fluorescent troffer new replacement lens, 2' x 2', remove and installEa.
24026015 081 0964Fluorescent troffer new replacement lens, 2' x 4', remove and installEa.
24126050 510 0200Conduit, electric metallic tubing (EMT), 1/2" to 1" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangersL.F.
24226050 510 0220Conduit, electric metallic tubing (EMT), 1-1/4" to 1-1/2" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangersL.F.
24326050 510 0240Conduit, electric metallic tubing (EMT), 2" to 3" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangersL.F.
24426050 510 0260Conduit, electric metallic tubing (EMT), 3-1/2" to 4" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangersL.F.
24526050 510 0310Armored cable, (BX), #12, 3 wire, average 50' runs, electrical demolition, removeL.F.
24626050 510 0370Non metallic sheathed cable, (Romex), #14, 3 wire, electrical demolition, removeL.F.
24726050 510 0390Non metallic sheathed cable, (Romex), #10, 3 wire, electrical demolition, removeL.F.
24826050 510 0465Wiremold raceway, telephone/power pole, electrical demolition, removeEa.
24926050 510 1780Receptacle & switch plates, electrical demolition, removeEa.
25026050 510 1790Receptacle & switches, 15 to 30 amp, electrical demolition, removeEa.
25126050 510 1860Wire, THW-THWN-THHN, #8, electrical demolition, removed from in place conduit, to 15' highC.L.F.
25226050 510 2140Fluorescent fixtures, interior, 4 lamp, 2' x 4', electrical demolition, remove, recessed drop-in, to 15' high, including supports & whipsEa.
25326050 520 3210Undercarpet, power or telephone, flat cable, electrical demolition, removeL.F.
25426050 520 6000Floor box and carpet flange, electrical demolition, removeEa.
25526050 520 6310Wireway, to 10' high, 2-1/2" x 2-1/2", electrical demolition, remove, incl fittings and supportsL.F.
25626050 520 7008Receptacle, explosion proof, 120 V, to 30 A, electrical demolition, removeEa.
25726050 550 3010Metal light pole, 10' high, electrical demolition, remove, excludes concrete basesEa.
25826050 550 4200Fluorescent fixture, explosionproof, electrical demolition, removeEa.
25926050 550 5000Ballast, fluorescent fixture, electrical demolition, removeEa.
26026050 550 5310Exit light, electrical demolition, removeEa.
26126050 550 5320Emergency battery pack lighting unit, electrical demolition, removeEa.
26226051 920 9050Metal clad cable, copper, aluminum clad, 600 volt, 3 wire, #12C.L.F.
26326051 990 0030Wire, copper, solid, 600 volt, #12, type THWN-THHN, normal installation conditions in wireway, conduit, cable trayC.L.F.
26426051 990 0100Wire, copper, stranded, 600 volt, #12, type THWN-THHN, normal installation conditions in wireway, conduit, cable trayC.L.F.
26526051 990 0120Wire, copper, stranded, 600 volt, #10, type THWN-THHN, normal installation conditions in wireway, conduit, cable trayC.L.F.
26626051 990 1300Wire, copper, stranded, 600 volt, #8, type THWN-THHN, normal installation conditions in wireway, conduit, cable trayC.L.F.
26726053 313 1770Rigid galvanized steel conduit, 3/4" diameter, to 10' H, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LFL.F.
26826053 313 2500Intermediate metal conduit, 1/2" diameter, to 10' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LFL.F.
26926053 313 5020Electric metallic tubing (EMT), 3/4" diameter, to 10' high, incl 2 terminations, 2 field bend elbows, 11 beam clamps, and 11 couplings per 100 LFL.F.
27026053 316 0020Outlet boxes, pressed steel, 4" octagonEa.
27126053 316 0060Outlet boxes, pressed steel, covers, blank, 4" octagonEa.
27226053 316 0150Outlet boxes, pressed steel, 4" squareEa.
27326053 316 0250Outlet boxes, pressed steel, covers, blank, 4" squareEa.
27426053 316 0300Outlet boxes, pressed steel, plaster rings, 4" square, concealedEa.
27526092 310 0110Lighting devices, occupancy sensors, ultrasonic, ceiling mountedEa.
27626092 310 0120Lighting devices, occupancy sensors, dual technology, ceiling mountedEa.
27726241 620 0100Circuit breakers, bolt-on, 10k A.I.C., 1 pole 120 volt 10-50 ampEa.
27826241 620 0400Circuit breakers, bolt-on, 10k A.I.C., 2 pole 240 volt 10-50 ampEa.
27926241 620 0300Circuit breakers, bolt-on, 10 k A I.C., 1 pole, 120 volt, 70 ampEa.
28026241 620 0600Circuit breakers, bolt-on, 10 k A I.C., 2 pole, 240 volt, 80-100 ampEa.
28126241 620 0900Circuit breakers, bolt-on, 10 k A I.C., 3 pole, 240 volt, 80-100 ampEa.
28226272 340 0100Surface raceway, metal, straight section, no. 500L.F.
28326272 340 0670Surface raceway, metal, straight section, base & cover, blank, no. 2400L.F.
28426272 340 4120Surface raceway, tele-power pole, aluminum, w/ 2 receptacle, 12'Ea.
28526272 620 0500Toggle switch, quiet type, single pole, 20 ampEa.
28626272 620 08003 way switch, 20 ampEa.
28726272 620 10004 way switch, 20 ampEa.
28826272 620 2470Duplex receptacle, grounded, 120 volt, 20 ampEa.
28926272 620 2480Duplex receptacle, ground fault interrupting, 15 ampEa.
29026272 620 3600Receptacle, 20 amp, 250 volt, NEMA 6Ea.
29126272 620 5160Plug, 30 amp, 125 volt, NEMA 5Ea.
29226281 610 0600Circuit breaker, 3 pole, 600 volt, 225 amp, enclosed (NEMA 1)Ea.
29326281 620 3000Safety switches, heavy duty, 3 pole, fusible, 240 volt, 60 amp, NEMA 1Ea.
29426511 355 3020Interior LED fixtures, linear suspended mounted, 74 watt, two light bar 4' long, incl lamps mounting hardware and connectionsEa.
29526511 350 0300Fluorescent fixture, interior, acrylic lens, grid recess ceiling mounted, 2-U40 W, 2' W x 2' L, incl lamps, mounting hardware and connectionsEa.
29626511 350 0500Fluorescent fixture, interior, acrylic lens, grid recess ceiling mounted, 3-40 W, 2' W x 4' L, incl lamps, mounting hardware and connectionsEa.
29726511 350 0800Fluorescent fixture, interior, acrylic lens, grid recess ceiling mounted, 6-40 W, 4'W x 4'L, incl lamps, mounting hardware and connectionsEa.
29826511 350 1700Fluorescent fixture, interior, surface mounted, acrylic lens, 6-40 W, 4' W x 4' L, incl lamps, mounting hardware and connectionsEa.
29926511 350 3510Fluorescent fixture, interior, troffer parabolic lay-in, 1-32 W T8, 1' W x 4' L, incl lamps, mounting hardware and connectionsEa.
30026511 350 3525Fluorescent fixture, interior, troffer parabolic lay-in, 2-U32 W T8, 2' W x 2' L, incl lamps, mounting hardware and connectionsEa.
30126511 350 3530Fluorescent fixture, interior, troffer parabolic lay-in, 3-32 W T8, 2' W x 4' L, incl lamps, mounting hardware and connectionsEa.
30226121 355 0000Interior Dimmable LED fixtures, linear suspended mounted, 74 watt, two light bar 4' long, incl lamps mounting hardware and connectionsEa.
30326511 350 7640Dimmable ballast, replacement, interior lighting fixtures, one-lamp, to 15' highEa.
30426511 350 7650Dimmable ballast, replacement, interior lighting fixtures, two-lamp, to 15' highEa.
30526511 350 7660Dimmable ballast, replacement, interior lighting fixtures, three-lamp, to 15' highEa.
30626521 310 0500Emergency lighting units, lead battery operated, twin sealed beam light, 25 W, 6 V eachEa.
30726521 316 0080Exit lighting, incandescent, single face, ceiling or wall mountEa.
30826612 310 0125Fluorescent lamp, rapid start, cool white, energy saver, 25 watt, 3' longC
30927050 520 0220Voice/data outlet, electrical demolition, removeEa.
31027151 313 2300Telephone cable, telephone twisted, PVC insulation, #22-4 conductorC.L.F.
31127151 313 7000Unshielded twisted pair (UTP) cable, solid, PVC jacket, #24, 4 pair, category 5C.L.F.
31227151 313 7242Unshielded twisted pair (UTP) cable, solid, plenum, #24, 4 pair, category 6C.L.F.
31327151 313 7401Voice/data expansion module, modular jack,cat 6 keystone,RJ45, office white, cat 6 keystone,RJ45, office whiteEa.
31427154 313 1020Voice/data wall plate, plastic, 1 gang, 2-port, excl voice/data devicesEa.
31527154 313 1140Voice/data wall plate, stainless steel, 1 gang, 2-port, excl voice/data devicesEa.
31628050 510 1060Video camera, electrical demolition, removeEa.
31728050 510 1130Video monitor, 19", electrical demolition, removeEa.
31828050 510 1210Fire alarm horn and strobe light, electrical demolition, removeEa.
31928050 510 1220Flame detector, electrical demolition, removeEa.
32028050 510 1240Smoke detector, electrical demolition, removeEa.
32128050 510 1250Fire alarm pull station, electrical demolition, removeEa.
32228050 510 1260Fire alarm control panel, 4 to 8 zone, electrical demolition, removeEa.
32328050 510 1280Fire alarm annunciation panel, 4 to 8 zone, electrical demolition, removeEa.
32428151 111 0700Access control equipment, entrance card reader, barium ferriteEa.
32528461 127 5240Detection system, smoke detector, addressable type, excl. wires & conduitEa.
32628461 150 5010Detection system, fire alarm, detector, heat (addressable type), excl. wires & conduitEa.
32728462 504 4160Detection system, fire alarm control panel, addressable without voice, up to 200 points, excluding wires & conduitsEa.
32828462 050 4400Detection system, UPS battery charger, signal bell, excluding wires & conduitsEa.
32928462 050 4610Detection system, fire alarm signal bell 10" red 20-24 V PEa.
33028462 050 5460Detection system, signal bell for fire alarm, trouble buzzer or manual station, excluding wires & conduitsEa.
33128462 050 5600Detection system, strobe & horn, excluding wires & conduitsEa.
33228462 050 5610Detection system, strobe & horn, ADA type, excluding wires & conduitsEa.
33328462 050 5800Detection system, fire alarm horn, excluding wires & conduitsEa.
33428462 050 7800Detection system, remote annunciator, 8 zone lamp, excluding wires & conduitsEa.
33534711 317 2700Security vehicle barriers, pipe bollards, steel, concrete filled/painted, 8' L x 4' D hole, 8" diam.Ea.
SUBTOTAL BY YEAR$0.00$0.00$0.00$0.00$0.00
Puerto Rico
GC Overhead (In House)PCT$0.00$0.00$0.00$0.00$0.00
GC Profit (In House)PCT$0.00$0.00$0.00$0.00$0.00
SUBTOTAL WITH OH&P =$0.00$0.00$0.00$0.00$0.00
US Virgin Islands
USVI Escalation FactorFACTOR
SUBTOTAL BY YEAR - USVI$0.00$0.00$0.00$0.00$0.00
GC Overhead (In House)0.00%PCT$0.00$0.00$0.00$0.00$0.00
GC Profit (In House)0.00%PCT$0.00$0.00$0.00$0.00$0.00
SUBTOTAL WITH OH&P =$0.00$0.00$0.00$0.00$0.00
PUERTO RICOUS VIRGIN ISLANDSTOTALS
SUBTOTAL FOR ALL YEARS$0.00$0.00$0.00
TOTAL OH=$0.00$0.00$0.00
TOTAL PROFIT =$0.00$0.00$0.00
TOTAL PROPOSAL=$0.00

File details come from the government source that posted it. Updated .