Solicitation Amendment 47PB0024R0009 0002 2023 12 12.pdf

PDF 9 MB Posted

Attached to
Demolition of the Hoosac Stores Building at the Charlestown Navy Yard
Solicitation number
47PB0024R0009
Issued by

About this file

This is an amendment to a solicitation for the demolition of the Hoosac Stores Building at the Charlestown Navy Yard.

The amendment provides drawings from Volume III of the specification in 11x17 format, a sign-in sheet from a site visit held on December 7, 2023, extends the due date for questions from December 12, 2023 to December 15, 2023, and extends the proposal due date from December 29, 2023 to January 12, 2024. The purpose is to provide additional documentation and allow more time for questions and proposals. The General Services Administration Public Buildings Service Region 1 is seeking offers for demolition of the specified building as part of redevelopment plans for the area.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

The Purpose of this amendment is to:

1. Provide drawings from Volume III of the Specification in 11x17 format.

2. Provide the sign-in sheet from the site visit held on 12/7/2023.

3. Extend the due date for questions from 12/12/2023 to 12/15/2023.

4. The proposal due date is extended from 12/29/2023 to 1/12/2024.

All other terms and conditions remain unchanged.

358 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 359GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL marble fairbanks marble fairbanks

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

1 2 3 4 5 6 7 8 9

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

FOUNDATION

-11' - 3"

FOUNDATION

-11' - 3"

EAST GRADE

-3' - 8"

EAST GRADE

-3' - 8"

3'

- 8

SK-01

SK-01

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

HF G

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

H FG

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

South Elevation - Exterior

Feasability Study - Hoosac Building SK-01

HMC

1 South Elevation - Exterior

2 Penthouse East Elevation 3 Penthouse West Elevation

S-2.2

S-6.2S-6.1

S-2.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A1 OF A21

360 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 361GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

HB C D E F GA

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

FOUNDATION

-11' - 3"

FOUNDATION

-11' - 3"

SOUTH GRADE

-3' - 0"

SOUTH GRADE

-3' - 0"3'

- 0

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

West Elevation - Exterior

Feasability Study - Hoosac Building SK-02

HMC

1 West Elevation - Exterior

W-2.1

W-4.1

W-6.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A2 OF A21

362 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 363GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

12345678

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

FOUNDATION

-11' - 3"

FOUNDATION

-11' - 3"

WEST GRADE

-2' - 8"

WEST GRADE

-2' - 8"2'

- 8

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

North Elevation - Exterior

Feasability Study - Hoosac Building SK-03

HMC

1 North Elevation - Exterior

N-2.1

N-6.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A3 OF A21

364 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 365GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

H BCDEFG A

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

FOUNDATION

-11' - 3"

FOUNDATION

-11' - 3"

NORTH GRADE

-8"

NORTH GRADE

-8"8"

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

East Elevation - Exterior

Feasability Study - Hoosac Building SK-04

HMC

1 East Elevation - Exterior

E-2.1

E-6.1

E-4.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A4 OF A21

366 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 367GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 1 Framing Plan

Feasability Study - Hoosac Building SK-05

HMC

1 FLOOR 1 Framing

Column 2B

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

Note: No material testing samples collected from this level.

SHEET A5 OF A21

368 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 369GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 2 Framing Plan

Feasability Study - Hoosac Building SK-06

HMC

1 FLOOR 2 Framing

Stringer FL2-A.1 A.2 A.3 A.4

Stringer FL2-B.1 B.2 B.3 B.4

Stringer FL2-C.1 C.2 C.3 C.4

Stringer FL2-D.1 D.2 D.3 D.4

Stringer FL2-E.1 E.2 E.3 E.4

Stringer FL2-F.1 F.2 F.3 F.4

Stringer FL2-G.1 G.2 G.3 G.4

Gi rd er F

L2 -2

Gi rd er F

L2 -3

Gi rd er F

L2 -4

Gi rd er F

L2 -5

Gi rd er F

L2 -6

Gi rd er F

L2 -7

Gi rd er F

L2 -8

Gi rd er F

L2 -9

Column 2B

BMS are smaller than Typ. ~15.5"T x 4"W

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A6 OF A21

Steel Beam Sample S1

370 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 371GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 3 Framing Plan

Feasability Study - Hoosac Building SK-07

HMC

1 FLOOR 3 Framing

Stringer FL3-A.1 A.2 A.3 A.4

Stringer FL3-B.1 B.2 B.3 B.4

Stringer FL3-C.1 C.2 C.3 C.4

Stringer FL3-D.1 D.2 D.3 D.4

Stringer FL3-E.1 E.2 E.3 E.4

Stringer FL3-F.1 F.2 F.3 F.4

Stringer FL3-G.1 G.2 G.3 G.4

Gi rd er F

L3 -2

Gi rd er F

L3 -3

Gi rd er F

L3 -4

Gi rd er F

L3 -5

Gi rd er F

L3 -6

Gi rd er F

L3 -7

Gi rd er F

L3 -8

Gi rd er F

L3 -9

Column 2B

Timber Sample 3C

Timber Sample 3B

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A7 OF A21

Steel Beam Sample S2

372 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 373GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 4 Framing Plan

Feasability Study - Hoosac Building SK-08

HMC

1 FLOOR 4 Framing

Stringer FL4-A.1 A.2 A.3 A.4

Stringer FL4-B.1 B.2 B.3 B.4

Stringer FL4-C.1 C.2 C.3 C.4

Stringer FL4-D.1 D.2 D.3 D.4

Stringer FL4-E.1 E.2 E.3 E.4

Stringer FL4-F.1 F.2 F.3 F.4

Stringer FL4-G.1 G.2 G.3 G.4

Gi rd er F

L4 -2

Gi rd er F

L4 -3

Gi rd er F

L4 -4

Gi rd er F

L4 -5

Gi rd er F

L4 -6

Gi rd er F

L4 -7

Gi rd er F

L4 -8

Gi rd er F

L4 -9

Column 2B

Timber Sample 4D

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A8 OF A21

374 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 375GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 5 Framing Plan

Feasability Study - Hoosac Building SK-09

HMC

1 FLOOR 5 Framing

Stringer FL5-A.1 A.2 A.3 A.4

Stringer FL5-B.1 B.2 B.3 B.4

Stringer FL5-C.1 C.2 C.3 C.4

Stringer FL5-D.1 D.2 D.3 D.4

Stringer FL5-E.1 E.2 E.3 E.4

Stringer FL5-F.1 F.2 F.3 F.4

Stringer FL5-G.1 G.2 G.3 G.4

Gi rd er F

L5 -2

Gi rd er F

L5 -3

Gi rd er F

L5 -4

Gi rd er F

L5 -5

Gi rd er F

L5 -6

Gi rd er F

L5 -7

Gi rd er F

L5 -8

Gi rd er F

L5 -9

Column 2B

Timber Sample 5B

Timber Sample 5C

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A9 OF A21

376 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 377GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 6 Framing Plan

Feasability Study - Hoosac Building SK-10

HMC

1 FLOOR 6 Framing

Stringer FL6-A.1 A.2 A.3 A.4

Stringer FL6-B.1 B.2 B.3 B.4

Stringer FL6-C.1 C.2 C.3 C.4

Stringer FL6-D.1 D.2 D.3 D.4

Stringer FL6-E.1 E.2 E.3 E.4

Stringer FL6-F.1 F.2 F.3 F.4

Stringer FL6-G.1 G.2 G.3 G.4

Gi rd er F

L6 -2

Gi rd er F

L6 -3

Gi rd er F

L6 -4

Gi rd er F

L6 -5

Gi rd er F

L6 -6

Gi rd er F

L6 -7

Gi rd er F

L6 -8

Gi rd er F

L6 -9

Column 2B

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A10 OF A21

Note: No material testing samples collected from

378 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 379GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

SK-01

SK-01

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

T.O. Roof Framing Plan

Feasability Study - Hoosac Building SK-11

HMC

1 T.O. ROOF Framing

_FIELD NOTES LEGEND

Stringer TOR-A.1 A.2 A.3 A.4

Stringer TOR-B.1 B.2 B.3 B.4

Stringer TOR-C.1 C.2 C.3 C.4

Stringer TOR-D.1 D.2 D.3 D.4

Stringer TOR-E.1 E.2 E.3 E.4

Stringer TOR-F.1 F.2 F.3 F.4

Stringer TOR-G.1 G.2 G.3 G.4

Gi rd er T

OR

-2

Gi rd er T

OR

-3

Gi rd er T

OR

-4

Gi rd er T

OR

-5

Gi rd er T

OR

-6

Gi rd er T

OR

-7

Gi rd er T

OR

-8

Gi rd er T

OR

-9

Column 2B

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A11 OF A21

Note: No material testing

380 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 381GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 1 Floor Plan

Feasability Study - Hoosac Building SK-12

HMC

1 FLOOR 1 - EXISTING Floor Plan

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A12 OF A21

Note: No material testing

382 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 383GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 2 Floor Plan

Feasability Study - Hoosac Building SK-13

HMC

1 FLOOR 2 - EXISTING Floor Plan

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A13 OF A21

Note: No material testing

384 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 385GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 3 Floor Plan

Feasability Study - Hoosac Building SK-14

HMC

1 FLOOR 3 - EXISTING Floor Plan

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A14 OF A21

Note: No material testing

386 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 387GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 4 Floor Plan

Feasability Study - Hoosac Building SK-15

HMC

1 FLOOR 4 - EXISTING Floor Plan

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A15 OF A21

Note: No material testing

388 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 389GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 5 Floor Plan

Feasability Study - Hoosac Building SK-16

HMC

1 FLOOR 5 - EXISTING Floor Plan

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A16 OF A21

Note: No material testing

390 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 391GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

H H

B B

C C

D D

E E

F F

G G

A A

X

X

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

MDR 09/23/19191468.00Jacobs

Floor 6 Floor Plan

Feasability Study - Hoosac Building SK-17

HMC

1 FLOOR 6 - EXISTING Floor Plan

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SAMPLING LOCATIONS

SHEET A17 OF A21

Note: No material testing

392 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 393GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

123456789

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

Checker 10/04/19191468.00Author

South Elevation - Interior

Feasability Study - Hoosac Building SK-18

Approver

1 South Elevation - Interior

S-2.1S-2.2

S-6.2 S-6.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A18 OF A21

394 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 395GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

H BCDEFG A

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

PENTHOUSE ROOF

76' - 5"

PENTHOUSE ROOF

76' - 5"

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

Checker 10/04/19191468.00Author

West Elevation - Interior

Feasability Study - Hoosac Building SK-19

Approver

1 West Elevation - Interior

W-4.1

W-6.1

W-2.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A19 OF A21

396 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 397GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

1 2 3 4 5 6 7 8

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

Checker 10/04/19191468.00Author

North Elevation - Interior

Feasability Study - Hoosac Building SK-20

Approver

1 North Elevation - Interior

N-2.1

N-6.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A20 OF A21

398 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 399GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

FLOOR 1

0"

FLOOR 1

0"

FLOOR 2

11' - 0"

FLOOR 2

11' - 0"

HB C D E F GA

FLOOR 3

22' - 0"

FLOOR 3

22' - 0"

FLOOR 4

32' - 11"

FLOOR 4

32' - 11"

FLOOR 5

43' - 10"

FLOOR 5

43' - 10"

FLOOR 6

54' - 9"

FLOOR 6

54' - 9"

T.O. ROOF

66' - 6"

T.O. ROOF

66' - 6"

LEGEND:

= EFFLORESCENCE

= OTHER STAINING

(E.G. PAINT)

= NON-BRICK (E.G.

CONCRETE INFILL)

= PIPE PENETRATION

= MISMATCH BRICK

(PREVIOUS REPAIR)

= MISMATCH MORTAR

RS= RUSTED STEEL

ELEMENT

= LOOSE, MISSING OR ERODED BRICK

= LOOSE, MISSING OR ERODED MORTAR

X SP

OR

OR

X P

CR

= SPALL OR ERODED BRICK OR STONE

= PREVIOUS REPAIR IN BRICK OR STONE

= EMBEDDED METAL FASTENER

= DISPLACED OR BULGING MASONRY

= CRACKED BRICK

= EMBEDDED LIGHTLT

= OBSTRUCTION

Project:

Date:

Scale:

Drawing No.:

Title:

Drawn: Checked: Approved: Project No.:

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Simpson Gumpertz & Heger Inc.

480 Totten Pond Raod Waltham, Massachusetts 02451 l main: 781.907.9000 fax: 781.907.9009 www.sgh.com

NTS

Checker 10/04/19191468.00Author

East Elevation - Interior

Feasability Study - Hoosac Building SK-21

Approver

1 East Elevation - Interior

E-2.1

E-4.1

E-6.1

APPENDIX A - APPROXIMATE

LOCATION OF MASONRY

CORE AND MATERIAL

SHEET A21 OF A21

400 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION]

marble fairbanks

THIS PAGE LEFT INTENTIONALLY BLANK

APPENDIX B

Summary of Masonry Condition Assessment Survey

402 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 403GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

404 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 405GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

406 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 407GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

408 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 409GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

410 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 411GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

412 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 413GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

414 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 415GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

416 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 417GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

418 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION]

marble fairbanks

THIS PAGE LEFT INTENTIONALLY BLANK

APPENDIX C

Summary of Representative Timber Grading

420 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 421GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

A

B

2 3 4 5 6 7 8 9

C

D

E

F

G

H

'-1

1/

4"

'-6

'-6

'-6

'-6

'-6

'-9

/4

16'-8 3/4"± 15'-10"± 15'-9"± 15'-10"± 15'-10"± 16'-0"± 15'-11"± 15'-11"±

GRADED BASED ON

BEAM UNDERSIDE

NO. 1/2

GRADED BASED ON

BEAM UNDERSIDE

GRADED BASED ON

BEAM UNDERSIDE

LIMITED ACCESS

DUE TO EQUIPMENT

SMALLER TIMBER BEAM

SIZE IN THIS AREA TYP

EXISTING CAST IRON

COLUMNS AT LEVEL 2 TYP

1TG-1.8

GRADING LEGEND: BEAMS COLUMNS

SUMMARY

SELECT STRUCTURAL TIMBER GRADE

No. 1 TIMBER GRADE

No. 2 TIMBER GRADE

No. 3 TIMBER GRADE

UNGRADED:

TOTAL ELEMENTS GRADED:

7 (3%)

7 (3%)

4 (1.7%)

1 (0.4%)

213 (91.8%) 39

19 (8.2%) 0

TOTAL ELEMENTS: 232 (100%) 39

SHEET NOTES:

1. OBSERVATIONS SHOWN WERE MADE DURING SGH SITE VISITS ON 09, 15, & 18 OCTOBER 2019.

2. SGH SITE OBSERVATIONS OF EXISTING TIMBERS ARE LIMITED AND SGH DID NOT CONDUCT A

FULL TIMBER GRADING OR VISUAL SURVEY OF THE ENTIRE EXISTING BUILDING.

3. THE VISUAL GRADING OF EXISTING TIMBERS WAS BASED ON LIMITED OBSERVATIONS OF ALL

ACCESSIBLE TIMBER SURFACES AT THE TIME OF SGH'S SITE VISIT. PARTIALLY OBSTRUCTED

TIMBERS, HEAVILY PAINTED TIMBERS, AND INACCESSIBLE SURFACES COULD NOT BE GRADED OR

GRADED FULLY. EXISTING TIMBERS COULD ONLY BE REVIEWED BASED ON EXPOSED TIMBER

FACES. PORTIONS OF TIMBERS ENCLOSED OR COVERED BY FINISHES OR OTHER MATERIAL ARE

NOTED TO THE BEST EXTENT POSSIBLE.

4. ALL TIMBER BEAMS AND COLUMNS GRADED ARE ASSUMED TO BE SOUTHERN PINE SPECIES

BASED ON A WOOD MICROSCOPY EXAMINATION OF (4) LIMITED MATERIAL SAMPLES TAKEN AT

LEVELS 3, 4, 5, & 6 AS NOTED ON PLAN.

5. TIMBER VISUAL GRADING IS BASED ON THE 2014 STANDARD GRADING RULES FOR SOUTHERN

PINE LUMBER BY THE SOUTHERN PINE INSPECTION BUREAU (SPIB).

6. BEAMS SHOWN ON PLAN AT A SPECIFIC FLOOR LEVEL ARE VISIBLE WHEN STANDING ON THE

FLOOR LEVEL BELOW AND LOOKING UP. COLUMNS SHOWN ARE VISIBLE WHEN STANDING ON

THE NOTED FLOOR LEVEL.

7. SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR PROJECT AREAS OUTSIDE OF SGH SCOPE

OF WORK.

8. THE PROJECT STRUCTURAL ENGINEER OF RECORD (SER) IS RESPONSIBLE FOR SURVEYING THE

CONDITION OF EXISTING STRUCTURAL MEMBERS TO REMAIN AS PART OF THEIR FEASBILITY

STUDY.

Project

Date

ScaleDrawn

Checked

Approved

Project No.

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Drawing No.

Drawing Title

Seal

Consultant l Boston

Chicago Houston

Los Angeles New York

San Francisco Washington, DC

Simpson Gumpertz & Heger Inc.

480 Totten Pond Road Waltham, Massachusetts 02451 main: 781.907.9000 fax: 781.907.9009 www.sgh.com

FOR IN

FORMATIO

N O

NLY

As indicated

I:\

BO

S\ Pr oj ec ts \2

9\

.0

0- H

O O

S\ D ra w in gs

\W or ki ng

_S et

R ev it\

LO

C

AL

U

SE

R

S\ m jri ch ar d\

.0

0_ R

_H oo sa c Ti m be r G ra di ng

_C

EN

TR

AL

_m jri ch ar d.

rv t

/1 2/

0:

:4

AM

SGH 11/12/2019191468

MTW/MJR

TG-1.2

MJR

HOOSAC DOCKS

CHARLESTOWN, MA

FLOOR 2 TIMBER GRADING

No. Date Description By

1/8" = 1'-0"

FLOOR 2 PLAN

FOR INFORMATION ONLY

422 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 423GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

A

B

2 3 4 5 6 7 8 9

C

D

E

F

G

H

'-1

1/

4"

'-6

'-6

'-6

'-6

'-6

'-9

/4

16'-8 3/4"± 15'-10"± 15'-9"± 15'-10"± 15'-10"± 16'-0"± 15'-11"± 15'-11"±

LOCATION OF TIMBER

SAMPLE FOR TESTING

COLUMN PARTIALLY OBSTRUCTED

LIMITED SITE ACCESS PREVENTED REVIEW

OF (2) COLUMNS ALONG GRIDLINE 8

15 1/2" X 15 1/2" ± TIMBER COLUMN TYP THIS LEVEL

NO. 2/3

2 SIDES VISIBLE FOR GRADING

TG-1.8

TG-1.8

GRADING LEGEND: BEAMS COLUMNS

SUMMARY

SELECT STRUCTURAL TIMBER GRADE

No. 1 TIMBER GRADE

No. 2 TIMBER GRADE

No. 3 TIMBER GRADE

UNGRADED:

TOTAL ELEMENTS GRADED:

10 (4.3%)

4 (1.7%)

5 (2.2%)

1 (0.4%)

10 (25.6%)

3 (7.7%)

212 (91.4%) 26 (66.7%)

20 (8.6%) 13 (33.3%)

TOTAL ELEMENTS: 232 (100%) 39 (100%)

SHEET NOTES:

1. OBSERVATIONS SHOWN WERE MADE DURING SGH SITE VISITS ON 09, 15, & 18 OCTOBER 2019.

2. SGH SITE OBSERVATIONS OF EXISTING TIMBERS ARE LIMITED AND SGH DID NOT CONDUCT A

FULL TIMBER GRADING OR VISUAL SURVEY OF THE ENTIRE EXISTING BUILDING.

3. THE VISUAL GRADING OF EXISTING TIMBERS WAS BASED ON LIMITED OBSERVATIONS OF ALL

ACCESSIBLE TIMBER SURFACES AT THE TIME OF SGH'S SITE VISIT. PARTIALLY OBSTRUCTED

TIMBERS, HEAVILY PAINTED TIMBERS, AND INACCESSIBLE SURFACES COULD NOT BE GRADED OR

GRADED FULLY. EXISTING TIMBERS COULD ONLY BE REVIEWED BASED ON EXPOSED TIMBER

FACES. PORTIONS OF TIMBERS ENCLOSED OR COVERED BY FINISHES OR OTHER MATERIAL ARE

NOTED TO THE BEST EXTENT POSSIBLE.

4. ALL TIMBER BEAMS AND COLUMNS GRADED ARE ASSUMED TO BE SOUTHERN PINE SPECIES

BASED ON A WOOD MICROSCOPY EXAMINATION OF (4) LIMITED MATERIAL SAMPLES TAKEN AT

LEVELS 3, 4, 5, & 6 AS NOTED ON PLAN.

5. TIMBER VISUAL GRADING IS BASED ON THE 2014 STANDARD GRADING RULES FOR SOUTHERN

PINE LUMBER BY THE SOUTHERN PINE INSPECTION BUREAU (SPIB).

6. BEAMS SHOWN ON PLAN AT A SPECIFIC FLOOR LEVEL ARE VISIBLE WHEN STANDING ON THE

FLOOR LEVEL BELOW AND LOOKING UP. COLUMNS SHOWN ARE VISIBLE WHEN STANDING ON

THE NOTED FLOOR LEVEL.

7. SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR PROJECT AREAS OUTSIDE OF SGH SCOPE

OF WORK.

8. THE PROJECT STRUCTURAL ENGINEER OF RECORD (SER) IS RESPONSIBLE FOR SURVEYING THE

CONDITION OF EXISTING STRUCTURAL MEMBERS TO REMAIN AS PART OF THEIR FEASBILITY

STUDY.

Project

Date

ScaleDrawn

Checked

Approved

Project No.

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Drawing No.

Drawing Title

Seal

Consultant l Boston

Chicago Houston

Los Angeles New York

San Francisco Washington, DC

Simpson Gumpertz & Heger Inc.

480 Totten Pond Road Waltham, Massachusetts 02451 main: 781.907.9000 fax: 781.907.9009 www.sgh.com

FOR IN

FORMATIO

N O

NLY

As indicated

I:\

BO

S\ Pr oj ec ts \2

9\

.0

0- H

O O

S\ D ra w in gs

\W or ki ng

_S et

R ev it\

LO

C

AL

U

SE

R

S\ m jri ch ar d\

.0

0_ R

_H oo sa c Ti m be r G ra di ng

_C

EN

TR

AL

_m jri ch ar d.

rv t

/1 2/

0:

:4

AM

SGH 11/12/2019191468

MTW/MJR

TG-1.3

MJR

HOOSAC DOCKS

CHARLESTOWN, MA

FLOOR 3 TIMBER GRADING

No. Date Description By

1/8" = 1'-0"

FLOOR 3 PLAN

424 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 425GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

A

B

2 3 4 5 6 7 8 9

C

D

E

F

G

H

'-1

1/

4"

'-6

'-6

'-6

'-6

'-6

'-9

/4

16'-8 3/4"± 15'-10"± 15'-9"± 15'-10"± 15'-10"± 16'-0"± 15'-11"± 15'-11"±

12 1/4" X 12 1/4" ± TIMBER COLUMN TYP THIS LEVEL

COLUMN PARTIALLY OBSTRUCTED

COLUMN DAMAGE ON ONE CORNER

LOCATION OF TIMBER BEAM SAMPLE FOR TESTING

ON FLOOR LEVEL BELOW

LIMITED ACCESS DUE TO EQUIPMENT

GRADED BASED ON BEAM UNDERSIDE

GRADED BASED ON BEAM UNDERSIDE

TG-1.8

TG-1.8

TG-1.8

GRADING LEGEND: BEAMS COLUMNS

SUMMARY

SELECT STRUCTURAL TIMBER GRADE

No. 1 TIMBER GRADE

No. 2 TIMBER GRADE

No. 3 TIMBER GRADE

UNGRADED:

TOTAL ELEMENTS GRADED:

8 (3.4%)

4 (1.7%)

1 (0.4%)

3 (1.3%)

9 (2.3%)

2 (5.1%)

3 (7.7%)

216 (93.1%) 25 (64.1%)

16 (6.9%) 14 (35.9%)

TOTAL ELEMENTS: 232 (100%) 39 (100%)

SHEET NOTES:

1. OBSERVATIONS SHOWN WERE MADE DURING SGH SITE VISITS ON 09, 15, & 18 OCTOBER 2019.

2. SGH SITE OBSERVATIONS OF EXISTING TIMBERS ARE LIMITED AND SGH DID NOT CONDUCT A

FULL TIMBER GRADING OR VISUAL SURVEY OF THE ENTIRE EXISTING BUILDING.

3. THE VISUAL GRADING OF EXISTING TIMBERS WAS BASED ON LIMITED OBSERVATIONS OF ALL

ACCESSIBLE TIMBER SURFACES AT THE TIME OF SGH'S SITE VISIT. PARTIALLY OBSTRUCTED

TIMBERS, HEAVILY PAINTED TIMBERS, AND INACCESSIBLE SURFACES COULD NOT BE GRADED OR

GRADED FULLY. EXISTING TIMBERS COULD ONLY BE REVIEWED BASED ON EXPOSED TIMBER

FACES. PORTIONS OF TIMBERS ENCLOSED OR COVERED BY FINISHES OR OTHER MATERIAL ARE

NOTED TO THE BEST EXTENT POSSIBLE.

4. ALL TIMBER BEAMS AND COLUMNS GRADED ARE ASSUMED TO BE SOUTHERN PINE SPECIES

BASED ON A WOOD MICROSCOPY EXAMINATION OF (4) LIMITED MATERIAL SAMPLES TAKEN AT

LEVELS 3, 4, 5, & 6 AS NOTED ON PLAN.

5. TIMBER VISUAL GRADING IS BASED ON THE 2014 STANDARD GRADING RULES FOR SOUTHERN

PINE LUMBER BY THE SOUTHERN PINE INSPECTION BUREAU (SPIB).

6. BEAMS SHOWN ON PLAN AT A SPECIFIC FLOOR LEVEL ARE VISIBLE WHEN STANDING ON THE

FLOOR LEVEL BELOW AND LOOKING UP. COLUMNS SHOWN ARE VISIBLE WHEN STANDING ON

THE NOTED FLOOR LEVEL.

7. SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR PROJECT AREAS OUTSIDE OF SGH SCOPE

OF WORK.

8. THE PROJECT STRUCTURAL ENGINEER OF RECORD (SER) IS RESPONSIBLE FOR SURVEYING THE

CONDITION OF EXISTING STRUCTURAL MEMBERS TO REMAIN AS PART OF THEIR FEASBILITY

STUDY.

Project

Date

ScaleDrawn

Checked

Approved

Project No.

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Drawing No.

Drawing Title

Seal

Consultant l Boston

Chicago Houston

Los Angeles New York

San Francisco Washington, DC

Simpson Gumpertz & Heger Inc.

480 Totten Pond Road Waltham, Massachusetts 02451 main: 781.907.9000 fax: 781.907.9009 www.sgh.com

FOR IN

FORMATIO

N O

NLY

As indicated

I:\

BO

S\ Pr oj ec ts \2

9\

.0

0- H

O O

S\ D ra w in gs

\W or ki ng

_S et

R ev it\

LO

C

AL

U

SE

R

S\ m jri ch ar d\

.0

0_ R

_H oo sa c Ti m be r G ra di ng

_C

EN

TR

AL

_m jri ch ar d.

rv t

/1 2/

0:

:4

AM

SGH 11/12/2019191468

MTW/MJR

TG-1.4

MJR

HOOSAC DOCKS

CHARLESTOWN, MA

FLOOR 4 TIMBER GRADING

No. Date Description By

1/8" = 1'-0"

FLOOR 4 PLAN

426 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 427GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

A

B

2 3 4 5 6 7 8 9

C

D

E

F

G

H

'-1

1/

4"

'-6

'-6

'-6

'-6

'-6

'-9

/4

16'-8 3/4"± 15'-10"± 15'-9"± 15'-10"± 15'-10"± 16'-0"± 15'-11"± 15'-11"±

9 1/4" X 9 1/4" ± TIMBER COLUMN TYP THIS LEVEL

LOCATION OF TIMBER SAMPLE FOR TESTING

DAMAGE AT EXISTING COL.

LOCATION OF TIMBER DECKING SAMPLE FOR TESTING

1 SIDE VISIBLE FOR GRADING

2 SIDES VISIBLE FOR GRADING

1 SIDE VISIBLE FOR GRADING

2 SIDES VISIBLE FOR GRADING

SMALLER TIMBER BEAM

SIZE IN THIS AREA TYP

TG-1.8

TG-1.8

GRADING LEGEND: BEAMS COLUMNS

SUMMARY

SELECT STRUCTURAL TIMBER GRADE

No. 1 TIMBER GRADE

No. 2 TIMBER GRADE

No. 3 TIMBER GRADE

UNGRADED:

TOTAL ELEMENTS GRADED:

8 (3.4%)

4 (1.7%)

4 (1.7%)

1 (0.4%)

8 (20.5%)

4 (10.3%)

215 (92.7%) 26 (66.7%)

17 (7.3%) 13 (33.3%)

TOTAL ELEMENTS: 232 (100%) 39 (100%)

SHEET NOTES:

1. OBSERVATIONS SHOWN WERE MADE DURING SGH SITE VISITS ON 09, 15, & 18 OCTOBER 2019.

2. SGH SITE OBSERVATIONS OF EXISTING TIMBERS ARE LIMITED AND SGH DID NOT CONDUCT A

FULL TIMBER GRADING OR VISUAL SURVEY OF THE ENTIRE EXISTING BUILDING.

3. THE VISUAL GRADING OF EXISTING TIMBERS WAS BASED ON LIMITED OBSERVATIONS OF ALL

ACCESSIBLE TIMBER SURFACES AT THE TIME OF SGH'S SITE VISIT. PARTIALLY OBSTRUCTED

TIMBERS, HEAVILY PAINTED TIMBERS, AND INACCESSIBLE SURFACES COULD NOT BE GRADED OR

GRADED FULLY. EXISTING TIMBERS COULD ONLY BE REVIEWED BASED ON EXPOSED TIMBER

FACES. PORTIONS OF TIMBERS ENCLOSED OR COVERED BY FINISHES OR OTHER MATERIAL ARE

NOTED TO THE BEST EXTENT POSSIBLE.

4. ALL TIMBER BEAMS AND COLUMNS GRADED ARE ASSUMED TO BE SOUTHERN PINE SPECIES

BASED ON A WOOD MICROSCOPY EXAMINATION OF (4) LIMITED MATERIAL SAMPLES TAKEN AT

LEVELS 3, 4, 5, & 6 AS NOTED ON PLAN.

5. TIMBER VISUAL GRADING IS BASED ON THE 2014 STANDARD GRADING RULES FOR SOUTHERN

PINE LUMBER BY THE SOUTHERN PINE INSPECTION BUREAU (SPIB).

6. BEAMS SHOWN ON PLAN AT A SPECIFIC FLOOR LEVEL ARE VISIBLE WHEN STANDING ON THE

FLOOR LEVEL BELOW AND LOOKING UP. COLUMNS SHOWN ARE VISIBLE WHEN STANDING ON

THE NOTED FLOOR LEVEL.

7. SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR PROJECT AREAS OUTSIDE OF SGH SCOPE

OF WORK.

8. THE PROJECT STRUCTURAL ENGINEER OF RECORD (SER) IS RESPONSIBLE FOR SURVEYING THE

CONDITION OF EXISTING STRUCTURAL MEMBERS TO REMAIN AS PART OF THEIR FEASBILITY

STUDY.

Project

Date

ScaleDrawn

Checked

Approved

Project No.

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Drawing No.

Drawing Title

Seal

Consultant l Boston

Chicago Houston

Los Angeles New York

San Francisco Washington, DC

Simpson Gumpertz & Heger Inc.

480 Totten Pond Road Waltham, Massachusetts 02451 main: 781.907.9000 fax: 781.907.9009 www.sgh.com

FOR IN

FORMATIO

N O

NLY

As indicated

I:\

BO

S\ Pr oj ec ts \2

9\

.0

0- H

O O

S\ D ra w in gs

\W or ki ng

_S et

R ev it\

LO

C

AL

U

SE

R

S\ m jri ch ar d\

.0

0_ R

_H oo sa c Ti m be r G ra di ng

_C

EN

TR

AL

_m jri ch ar d.

rv t

/1 2/

0:

:4

AM

SGH 11/12/2019191468

MTW/MJR

TG-1.5

MJR

HOOSAC DOCKS

CHARLESTOWN, MA

FLOOR 5 TIMBER GRADING

No. Date Description By

1/8" = 1'-0"

FLOOR 5 PLAN

428 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 429GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

A

B

2 3 4 5 6 7 8 9

C

D

E

F

G

H

'-1

1/

4"

'-6

'-6

'-6

'-6

'-6

'-9

/4

16'-8 3/4"± 15'-10"± 15'-9"± 15'-10"± 15'-10"± 16'-0"± 15'-11"± 15'-11"±

LARGE CHECK

10X12 TIMBER GIRDERS ±

AT GIRDER LINES TYP THIS LEVEL

EXISTING TIMBER ROOF JOISTS

THIS LEVEL NOT GRADED

OBSERVED WATER STAININGOBSERVED WATER STAINING

TG-1.8

GRADING LEGEND: BEAMS COLUMNS

SUMMARY

SELECT STRUCTURAL TIMBER GRADE

No. 1 TIMBER GRADE

No. 2 TIMBER GRADE

No. 3 TIMBER GRADE

UNGRADED:

TOTAL ELEMENTS GRADED:

5 (11.1%)

1 (2.2%)

1 (2.2%)

232 38 (84.4%)

0 7 (15.6%)

TOTAL ELEMENTS:

GIRDERS JOISTS

232 45 (100%)

SHEET NOTES:

1. OBSERVATIONS SHOWN WERE MADE DURING SGH SITE VISITS ON 09, 15, & 18 OCTOBER 2019.

2. SGH SITE OBSERVATIONS OF EXISTING TIMBERS ARE LIMITED AND SGH DID NOT CONDUCT A

FULL TIMBER GRADING OR VISUAL SURVEY OF THE ENTIRE EXISTING BUILDING.

3. THE VISUAL GRADING OF EXISTING TIMBERS WAS BASED ON LIMITED OBSERVATIONS OF ALL

ACCESSIBLE TIMBER SURFACES AT THE TIME OF SGH'S SITE VISIT. PARTIALLY OBSTRUCTED

TIMBERS, HEAVILY PAINTED TIMBERS, AND INACCESSIBLE SURFACES COULD NOT BE GRADED OR

GRADED FULLY. EXISTING TIMBERS COULD ONLY BE REVIEWED BASED ON EXPOSED TIMBER

FACES. PORTIONS OF TIMBERS ENCLOSED OR COVERED BY FINISHES OR OTHER MATERIAL ARE

NOTED TO THE BEST EXTENT POSSIBLE.

4. ALL TIMBER BEAMS AND COLUMNS GRADED ARE ASSUMED TO BE SOUTHERN PINE SPECIES

BASED ON A WOOD MICROSCOPY EXAMINATION OF (4) LIMITED MATERIAL SAMPLES TAKEN AT

LEVELS 3, 4, 5, & 6 AS NOTED ON PLAN.

5. TIMBER VISUAL GRADING IS BASED ON THE 2014 STANDARD GRADING RULES FOR SOUTHERN

PINE LUMBER BY THE SOUTHERN PINE INSPECTION BUREAU (SPIB).

6. BEAMS SHOWN ON PLAN AT A SPECIFIC FLOOR LEVEL ARE VISIBLE WHEN STANDING ON THE

FLOOR LEVEL BELOW AND LOOKING UP. COLUMNS SHOWN ARE VISIBLE WHEN STANDING ON

THE NOTED FLOOR LEVEL.

7. SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR PROJECT AREAS OUTSIDE OF SGH SCOPE

OF WORK.

8. THE PROJECT STRUCTURAL ENGINEER OF RECORD (SER) IS RESPONSIBLE FOR SURVEYING THE

CONDITION OF EXISTING STRUCTURAL MEMBERS TO REMAIN AS PART OF THEIR FEASBILITY

STUDY.

Project

Date

ScaleDrawn

Checked

Approved

Project No.

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Drawing No.

Drawing Title

Seal

Consultant l Boston

Chicago Houston

Los Angeles New York

San Francisco Washington, DC

Simpson Gumpertz & Heger Inc.

480 Totten Pond Road Waltham, Massachusetts 02451 main: 781.907.9000 fax: 781.907.9009 www.sgh.com

FOR IN

FORMATIO

N O

NLY

As indicated

I:\

BO

S\ Pr oj ec ts \2

9\

.0

0- H

O O

S\ D ra w in gs

\W or ki ng

_S et

R ev it\

LO

C

AL

U

SE

R

S\ m jri ch ar d\

.0

0_ R

_H oo sa c Ti m be r G ra di ng

_C

EN

TR

AL

_m jri ch ar d.

rv t

/1 2/

0:

:4

AM

SGH 11/12/2019191468

MTW/MJR

TG-1.7

MJR

HOOSAC DOCKS

CHARLESTOWN, MA

ROOF TIMBER GRADING

No. Date Description By

1/8" = 1'-0"

ROOF PLAN

430 CONTRACT #: GS-00-P-16-BQ-D-7012 [MODIFICATION] 431GATEWAY CENTER AT HOOSAC - DEMOLITION PROJECT MANUAL

Project

Date

ScaleDrawn

Checked

Approved

Project No.

SIMPSON GUMPERTZ & HEGER

Engineering of Structures and Building Enclosures

Drawing No.

Drawing Title

Seal

Consultant l Boston

Chicago Houston

Los Angeles New York

San Francisco Washington, DC

Simpson Gumpertz & Heger Inc.

480 Totten Pond Road Waltham, Massachusetts 02451 main: 781.907.9000 fax: 781.907.9009 www.sgh.com

FOR IN

FORMATIO

N O

NLY

As indicated

I:\

BO

S\ Pr oj ec ts \2

9\

.0

0- H

O O

S\ D ra w in gs

\W or ki ng

_S et

R ev it\

LO

C

AL

U

SE

R

S\ m jri ch ar d\

.0

0_ R

_H oo sa c Ti m be r G ra di ng

_C

EN

TR

AL

_m jri ch ar d.

rv t

/1 2/

0:

:5

AM

SGH 11/12/2019191468

MTW/MJR

TG-1.8

MJR

HOOSAC DOCKS

CHARLESTOWN, MA

EXISTING CONDITIONS

PHOTOS

No. Date Description By

FOR

INFORMATION

ONLY

LEVEL 3 - BEAM SAMPLE LEVEL 4

(E) COND. LEVEL 3 COL. SAMPLE

LEVEL 3 COL. SAMPLE

LEVEL 4 - DECKING SAMPLE AT LEVEL 5

(E) COND. COL. DAMAGE TYP

LEVEL 5 - BEAM SAMPLE LEVEL 6

LEVEL 5 AT BEAM SAMPLE ABOVE

LEVEL 5 COL. SAMPLE

(E) COND. LEVEL 5

(E) COND. MINOR DAMAGE COL. CAP

(E) COND. WATER STAINING AT ROOF

(E) COND. NO. 3 GRADE TYP

2023 11 22 Hoosac Building Demolition Project Manual_EXTRACTED PAGES.pdf
00 TABLE OF CONTENTS
01 SPECIFICATIONS
01 00 00General Requirements
01 11 00 Summary of Work
01 26 01Contract Modification Procedures
01 27 00Definition of Contract Line Items
01 30 00Administrative Requirements
01 31 00Project Management and Coordination
01 32 16Construction Schedule
01 32 33Photo Documentation
01 33 23Submittal Procedures
01 35 13.22 Archaeological Protection
01 35 23Safety Requirements
01 35 91Historic Preservation Treatment Procedures
01 40 00Quality Requirements
01 42 00Reference Standards
01 50 00Temporary Facilities and Controls
01 54 40Protection of Work and Property
015719.12 Noise And Acoustics Management
01 57 23Under-an-Acre Pollution Prevention (UPP)
01 73 29Cutting and Patching
01 73 40Execution
01 74 19Construction Waste Management and Disposal
01 77 00Closeout Procedures
02 01 00General Site Conditions
02 05 50Selective Salvage and Storage
02 08 10Abatement of Asbestos Containing Materials
02 08 30Lead-Containing Material Management
02 22 10Selective Demolitions
02 41 00Demolition
31 10 00Site Preparation and Clearing
32 31 00 Site Improvements – Decorative Fence
Closeout and Operation & Maintenance (O&M) Requirements
Submittal List
Under-An-Acre Pollution Prevention Plan Template
02 EXISTING WOOD BEAM QUANTITY TAKEOFFS
03 APPENDIX
Existing Building Hazmat Report
Existing Building Materials Testing
Pre-Demolition Hazardous Materials Survey
Existing Boiler House Hazmat Report
Proposed Salvaged Material Storage Locations
NPS Desired Timber Salvage Quantities
topmostSubform[0]:
Page1[0]:
Code[0]: 1PQC
Copies[0]:
CheckBox9[0]: 1
Code[2]: 1PQB
NameandTitleOfficer[0]: Vanessa Colquitt, Contracting Officer
Is[0]: Off
CheckBox10[0]: Off
NameandAddress[0]:
DateSigned[1]:
Pages[0]: 42
AmendmentNo[0]: 0002
Dated10B[0]:
ModificationNo[0]:
AdministeredBy[0]: Acquisition Management Division (1PQ) Contract Operations Branch (1PQB), GSA/PBS

10 CAUSEWAY ST., RM 1100

BOSTON, MA 02222-1077 USA

FacilityCode[0]:
CheckBox13B[0]: Off
CheckBox13D[0]: Off
ReqNumber[0]: EQ1PC-24-0006
Dated9B[0]: 11/30/2023
C13[0]:
Description[0]: See attached.
NotExtended[0]: Off
Code[1]:
AmendmentNo[1]: 47PB0024R0009
ContractIDCode[0]:
DateSigned[0]:
CheckBox11[0]: 1
Page[0]: 1
AccountingData[0]:
CopiesReturned[0]:
CheckBox13A[0]: Off
IsNot[0]: Off
EffectiveDate[0]: 12/12/2023
A13[0]:
ProjectNo[0]:
CheckBox13C[0]: Off
Extended[0]: 1
D13[0]:
IssuedBy[0]: Acquisition Management Division (1PQ) Contract Operations Branch (1PQC), GSA/PBS

10 Causeway Street, Rm 1100 Boston, MA 02222-1077 USA NameandTitleSigner[0]:

File details come from the government source that posted it. Updated .