About this file
This is Addendum No. 1 issued by MI DTMB/DOC for the Baraga Correctional Facility Housing Unit 8 Roof Replacement project (File No. 472/22420.JBB). The bid date remains December 4, 2024. The addendum adds Metal Panel Systems – MP-175 from Cincinnati, OH as an approved manufacturer and updates specifications for the standing-seam metal roof panels, including one-piece fixed clips with 16 gauge nominal thickness zinc-coated steel sheet, 18-inch panel coverage, and 1.5-inch nominal panel height. Drawing revisions include corrections to the A-101 Housing Unit 8 Roof Plan note reference, updates to Details 2 and 4 on A-301 to match 1-1/2" specification requirements, and addition of sheet E-101A showing interior ceiling electrical scope.
The document includes interior and exterior photographs of Housing Unit 8 showing the existing conditions, with views of ceiling systems, roof structures, and building exterior. A meeting attendance record shows representatives from OHM Advisors, Copper Range Roofing, Coastal Construction Group, Wybben Construction, MDOC, and DTMB DCD attended a pre-bid meeting at the project site on November 7, 2024 at 11:00 am. The addendum emphasizes daily cleaning requirements with a magnet as specified in Appendix II – Special Working Conditions, though this is noted as a clarification rather than a change to the documents.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NO. 1
DATE: November 21, 2024
PROJECT: Baraga Correctional Facility Housing Unit 8 Roof Replacement
DTMB FILE NO.: 472/22420.JBB
OWNER: MI DTMB/DOC
BID DATE: Wednesday, December 4, 2024 ** THIS ADDENDUM DOES NOT CHANGE
THE BID DATE
The following shall be incorporated into the Contract Documents dated 30 SEPT 2024.
GENERAL
The pre-bid meeting attendance sheet is attached.
Clarification: NOT A CHANGE TO THE DOCUMENTS. Review Appendix II – Special Working Conditions, Item 11.b. requiring daily cleaning with a magnet.
Photos of building attached for general reference.
PROJECT MANUAL
074113.16 – STANDING-SEAM METAL ROOF PANELS
Add the following as an approved manufacturer/system.
2.2.B.1.d – Metal Panel Systems – MP-175. Cincinnati, OH. Steven Butsch 513-376-0900.
Replace section 2.2.B.3 – B.6 with the following:
3. Clips: One-piece fixed to accommodate thermal movement
a. Material:
1. 16 gauge nominal thickness, zinc-coated (galvanized) or aluminum-zinc alloy-coated steel sheet.
4. Panel Coverage: 18 inches.
5. Panel Height: 1.5 inches nominal
DRAWINGS
A-101 HOUSING UNIT 8 ROOF PLAN – Revised sheet attached correcting note reference to A.13.
A-301 DETAILS
Details 2 and 4 reference 2” standing seam. Revise these references to be nominally 1-1/2” to match specification requirements.
E-101A PARTIAL ELECTRICAL FLOOR PLAN – Added sheet indicating interior ceiling scope for electrical items.
End of Addendum No. 1