472_23434_CTS_Central Michigan - PA Upgrade - Addendum 01 - Complete.pdf

PDF 2 MB Posted

Attached to
472/23434. CTS; STF Paging Systems
Solicitation number
RFQ 171 240000000630 3
Issued by
Macomb County, Sterling Village, Michigan

About this file

This is Construction Bid Addendum No. 01 issued by the Department of Technology, Management and Budget (DTMB), State Facilities Administration Design and Construction Division for the State of Michigan. The project involves a Paging System upgrade at Central Michigan Correctional Facility (Central C.F.) in St. Louis, Michigan, with work including installation of a new audio paging system throughout the site to distribute announcements, tones, and emergency messages. The scope encompasses installing new audio distribution equipment, amplifiers, cabling, speakers, and microphones; removing all existing speakers and cabling; removing existing paging equipment and underground cabling on the East side of the facility; patching ceilings and holes where speakers are removed; and configuring the existing Ethernet network to support the audio paging system. The bid opening date is Wednesday, September 11, 2024, at 2:00 PM ET, with a mandatory pre-bid walkthrough required for all bidders. The contract time is 210 days from Notice to Proceed. The addendum clarifies key project requirements through seven questions and answers and three clarifications regarding conduit installation responsibilities, existing cable configurations, suspension methods, shift requirements for food service work, interface requirements with existing sirens, equipment access via Gator vehicles, and audio amplifier quantities and zones.

The bid includes three provisional allowances totaling $113,000: a contingency allowance of $35,000, a hydrovac allowance of $8,000, and an HVAC allowance of $70,000, with all allowances to include bonds and insurance. A performance bond and payment bond are required for all bids exceeding $50,000, and each bid must be accompanied by a five percent bid guarantee. The bid summary includes nine base bid line items covering speaker and cable equipment and labor, paging equipment and labor, removal of existing equipment, Ethernet switch configuration, code approvals, as-builts, and warranty, with specific manufacturer parts designated throughout the project specifications. Builders risk insurance is required unless otherwise indicated in the bid documents. The project is funded through the Department of Corrections with the file number 472/23434.CTS and funding code 472STFMaintProj. Bidders must acknowledge receipt of this addendum in the bid summary and bid form; failure to do so may result in bid rejection.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTMB-0414 (Rev 12/17)

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

State Facilities Administration Design and Construction Division

CONSTRUCTION BID ADDENDUM NO. 01

This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.

TO:

ALL BIDDERS

DATE ISSUED

9/4/2024

PROJECT NAME

Central Michigan – PA Upgrade

FILE NUMBER

472/23434.CTS

PROFESSIONAL

Commtech Design Inc.

PROJECT DIRECTOR

Chris Schanbeck

BID OPENING DATE:

9/11/2024

ADDENDUM ITEMS: (attach additional sheets and drawings if required) Attachments;

1. Meeting Attendance record, Pre-Bid sign-in sheets.

2. New bid Summary & Section 01020 with HVAC Allowance & Description

3. Drawing TC 301

4. See pictures attached to this Addendum that were taken at the site and are included for your enjoyment.

Specifications

1. Bid Summary & Section 01020.

Drawings reissued

1. TC301

a) Change quantity of Audio amplifiers associated with symbol WC from one to two amplifiers to be provided.

Questions:

1. Is the winning bidder responsible for conduit installation to support phones and face plates?

Answer. Yes. This is an all-inclusive bid that includes systems, cabling, raceway equipment and all systems install and configuration.

2. What cables are currently run through the 2” Conduit from the East Education Building to the CPC, Woodshop, and CMT Buildings?

Answer. Cat-6 underground rated Camera Cables

3. The bid pack specifies that J hooks should be suspended with threaded rod – are beam clamps to structural steel acceptable in place of suspending hooks with threaded rod?

Answer. Yes, Beam Clamps to structure al steel area acceptable

4. Please clarify if 2nd or 3rd shift is required for work in food service building?

Answer. Yes. Food service is second/third shift

5. During the walkthrough existing sirens were found on the East & West side. Will the new paging system be required to interface with these sirens??

Answer. No interface from the new paging system to the existing sirens is required.

http://www.michigan.gov/SIGMAVSS

6. Since job trailers and storage connex can only be placed on the East side parking lot, will a truck or gator be allowed into the facility to assist with getting materials and labor in and out each day?

Answer. Yes, A Contractor provided Gator will be allowed to enter the facility.

7. On sheets TC303 and TC304 there do not appear to be enough 70V amplifiers shown to support the number of zones in each building. Are we to combine zones together?

Answer. See update to Part number WC. This amplifier does not hve 4 Zones in 70 volt but only two.

Provide a Quantity of two (2) amplifiers at each Symbol WC. See Updated sheet TC301

Clarifications:

1. Access is a concern with all the other projects going on at the facility - The facility should allow them to have space for one trailer or Conex box near the West Maintenance Building. There will be limited parking with most vehicles to be parked in front of West Admin.

2. The contractor is to provide their own work vehicle and if necessary, trailer that is stripped down and securable to enter the secure perimeter fence for work inside the facility.

3. Normal working hours are anticipated except for work in the Food Services Building where night shift hours shall be included in order to minimize disruption.

ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.

PROFESSIONAL: Bret Emerson, Commtech Design DATE: 9/42024

APPROVED BY:

PROJECT DIRECTOR: Chris Schanbeck DATE: 9/4/2024

Relevant pictures from the Pre-Bid Meeting Walkthru.

Admin Building

West Food Service

West Education

East Education

East Food Service

DTMB-0401D (R 03/21)

BID SUMMARY

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

STATE FACILITIES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

3111 W. St. Joseph Street Lansing, Michigan 48917

Bids must be submitted electronically through the SIGMA VSS website at https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService

FILE NUMBER

472/23434.CTS

FUNDING CODE

472STFMaintProj

DEPARTMENT/AGENCY

Corrections

CONTRACT TIME(S)

210 Days from Notice to Proceed

PROJECT NAME

Paging System

LOCATION

Central C.F. (STF)

BID OPENING DATE

Wednesday September 11th, 2024 at 2:00 pm ET

FOR AN EXAMINATION OF THE SITE CONTACT:

Must attend Mandatory pre-bid walk through

SEE SECTION 00100 INSTRUCTIONS TO BIDDERS AND SECTION 00700 GENERAL CONDITIONS PROVIDED WITH THE BIDDING DOCUMENTS.

BID: WE PROPOSE TO FURNISH, PERFORM AND COMPLETE THE ENTIRE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS IN

CONSIDERATION OF THE BID PRICE (S) STATED BELOW.

FIRM NAME AND COMPLETE ADDRESS TELEPHONE NUMBER and E-MAIL ADDRESS

□ Qualified Disabled Veteran

SIGMA VENDOR NUMBER

(protected information required for processing payments)

BIDDER'S SIGNATURE AND TITLE DATE

WITNESS' SIGNATURE DATE

By signing this bid above, bidder certifies their enclosed Qualified Disabled Veteran and Michigan-Based Business Certifications.

BASE BID FROM BID SCHEDULE (Include specified Allowances):

____________________________________________________________________________Dollars $____________________ (use words) (in figures)

Alternate1: (Add) ______________________________________________________ Dollars $ ____________________ (use words) (in figures)

Alternate 2: (Add/Subtract) ______________________________________________________Dollars $ ____________________ (use words) (in figures)

Alternate 3: (Add/Subtract) ______________________________________________________Dollars $ ____________________ (use words) (in figures)

A PERFORMANCE BOND AND A PAYMENT BOND ARE REQUIRED FOR ALL BIDS OVER $50,000.00. EACH BID MUST BE ACCOMPANIED BY A FIVE (5) PERCENT BID GUARANTEE. BUILDERS RISK INSURANCE IS REQUIRED TO BE PROVIDED BY THE CONTRACTOR UNLESS

OTHERWISE INDICATED IN THE BID DOCUMENTS.

BIDDERS ARE ALSO CAUTIONED TO FAMILIARIZE THEMSELVES WITH ALL OF THE OTHER CONDITIONS OF THE CONTRACT.

Project Scope of Work:

• Base Bid – Work associated with the Paging system shall be included in the Base Bid pricing.

o Paging System Upgrade scope includes but is not limited to:

▪ Install a new audio paging systems throughout the site to support distribution of announcements, tones and emergency messages.

▪ The paging system shall be distributed on the secure ethernet network from the Administration Building to all other buildings. There shall be local microphones at the housing units and other buildings as noted on the drawings.

https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService

▪ Install new audio distribution equipment, audio amplifiers, cabling, speakers and microphones as required to provide a completed audio system for the site. See floorplans for locations of existing speakers and new speakers. Remove all existing speakers and cabling and remove from the site.

▪ Patch ceilings and holes where existing speakers are being removed.

▪ Work shall include configuration of the existing Ethernet network to support the audio paging system.

▪ Work shall include removal of existing paging equipment at each building where it is not required. Remove existing cabling in buildings where it is not being re-used. Remove existing underground paging system cabling on the East side of the facility. Remove from underground conduits .

The Bidder must figure its Base Bid on the specified, or Addendum-approved, materials and equipment only. No “or equal” or substitution proposals will be permitted after Bid opening, except as provided in the General Conditions.

Addenda: Bidder acknowledges receipt of Addenda: No. ___ dated: ________, No. ___ dated: ________ No. ___ dated: ________

FIRM NAME TELEPHONE NUMBER and E-MAIL ADDRESS

BID SCHEDULE

Base Bid Schedule - The Bidder will complete the Work and accept as full payment, for the Work items listed, the following Unit Prices and/or Item Bid Prices, as applicable:

Base Bid Item No.

Bid Quantity

Description

Unit Price

Item Bid Price

1 1 Speaker /cable Equipment

2 1 Speaker /cable Labor

3 1 Paging Equipment

4 1 Paging Labor

5 1 Remove existing Paging equipment and cables

6 1 Ethernet Switch configuration and connection labor

7 1 2% Code Approvals

8 1 2% As-Builts

9 1 2% Warranty

HVAC ALLOWANCE $70,000.00 $70,000.00

HYDROVAC ALLOWANCE $8,000.00 $8,000.00

ALLOWANCE AMOUNT $35,000.00 $35,000.00

TOTAL (This amount should equal the Base Bid amount on the Bid Summary Form) $

Base Bid (Sum of Item Bid Prices for all Base Bid Items):

__________________________________________________________________ Dollars $__________________________ (use words) (in figures)

SECTION 01020 ALLOWANCES

1. Allowances

1.1 Cash Allowances:

(a) None

1.2 Provisional/Contingency Allowances:

(a) Bidders must include in their Base Proposal Sum two separate allowances.

a. A contingency allowance of $35,000.00 The base bid shall include bonds and insurance on the value of the allowance.

b. A Hydrovac allowance of $8,000.00 The base bid shall include bonds and insurance on the value of the allowance.

i. See SPECIAL WORKING CONDITIONS. Appendix II.

c. A HVAC Allowance of $70,000.00 - The base bid shall include bonds and insurance on the value of the allowance

i. The owner will be requesting an HVAC system upgrade at the Administration room to serve the comm room etc. This work will be designed and later included as part of the HVAC Allowance

(b) Monies will be used in the contingency allowance only if directed in writing by the Project Director and Professional.

(c) Payments under a Provisionary Allowance will include not only the purchase/furnished cost of the materials and equipment involved, but also all related labor costs, subcontract costs, construction equipment costs, general conditions costs and Fee, provided they are calculated in accordance with the requirements of the contract documents.

(c ) Unused allowances will be deducted from the contract amount through contract change order.

END OF SECTION 01020

SPEAKER SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

AUDIO VIDEO SYMBOL LEGEND

SYMBOL DESCRIPTION

ABBREVIATIONS

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

AUDIO/VIDEO CABLE SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

TC301

DATA CABLE AND RACEWAY FOR

WALL MOUNT MICROPHONE

TC301

DATA CABLE AND RACEWAY FOR

DESK MOUNT MICROPHONE

TC301

DATA CABLE AND RACEWAY FOR

CENRAL CONTROL TOUCHPANEL

AUDIO EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

TC301

CENTRAL

PAGING LEGENDS, DETAILS

AND SCHEDULES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

C om m te ch

D es ig n

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

AutoCAD SHX Text PAGING SYSTEM SPEAKER FOR DROP CEILING INSTALLATION. EQUIP WITH WHITE GRILL AND MULTI TAPS. PROVIDE T-BAR AND BACKBOX

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

SD72WV

AutoCAD SHX Text PAGING SYSTEM SPEAKER. SURFACE MOUNTED, INCLUDES BACKBOX. SHALL BE SURFACE MOUNTED FROM THE BUILDING STRUCTURE.

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

SBMS

AutoCAD SHX Text

PAGING SYSTEM SPEAKER. INDOOR/OUTDOOR HORN.

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

GA-30T

AutoCAD SHX Text PAGING SYSTEM SPEAKER. SURFACE MOUNTED, INCLUDES BACKBOX. SHALL BE SURFACE MOUNTED FROM THE BUILDING STRUCTURE. FOR VANDAL PROOF AREAS

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

VP14MB WI/VP14ENC

AutoCAD SHX Text

PAGING SYSTEM SPEAKER. OUTDOOR RATED. 8" EQUIP WITH MOUNT AND SAFETY STRAP

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

SM82T-B

AutoCAD SHX Text

LARGE AUDIO SPEAKER. OUTDOOR RATED. 12" EQUIP WITH MOUNT AND SAFETY STRAP

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

FS12T-94

AutoCAD SHX Text EXISTING PAGING SPEAKER AND BACKBOX. REMOVE SPEAKER. REPLACE SPEAKER WITH A NEW SPEAKER. LEAVE BACKBOX AND COVER. FIT SPEAKER INTO EXISTING BOX AND COVER.

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

SD72

AutoCAD SHX Text EXISTING PAGING SPEAKER TO BE REMOVED. REMOVE SPEAKER AND CABLE ASSOCIATED WITH SPEAKER. DISPOSE OF OFFSITE. SEAL HOLE ON WALL OR CEILING OR WALL. FILL WITH DRYWALL MUD ON DRYWALL WALLS. APPLY CLEAR SEALANT ON BLOCK OR CONCRETE WALLS.

AutoCAD SHX Text

EXISTING TO BE REMOVED

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text THIS SYMBOL WITH A NUMBER INSIDE REFERS TO KEYNOTES. REFER TO NOTES ON THE SHEET OR WITHIN THE DETAIL FOR ADDITIONAL INFORMATION

AutoCAD SHX Text EQUIPMENT SCHEDULE. THIS SYMBOL WITH LETTERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text CABLE SCHEDULE. THIS SYMBOL WITH NUMBERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text AUDIO/VIDEO COMMUNICATIONS OUTLET. REFER TO THE ASSOCIATED AV SYSTEM DETAIL FOR REQUIREMENTS. ZZ REFERS TO HEIGHT OF OUTLET. 18" UNLESS OTHER WISE NOTED.

AutoCAD SHX Text AV SYSTEM DETAIL. REFER TO THIS SHEET AND DETAIL NUMBER FOR THE REQUIREMENTS OF THE AUDIO/VIDEO SYSTEM IN THIS ROOM

AutoCAD SHX Text SPEAKERS. SEE SPEAKER SCHEDULE ON TC301."X" REFERS TO SPEAKER TYPE. "ZZ" REFERS TO SPEAKER ZONE.

AutoCAD SHX Text EXISTING SPEAKERS TO BE REMOVED. REMOVE CABLE FROM THE BUILDING THAT USED TO FEED TO SPEKER

AutoCAD SHX Text SURFACE RACEWAY SYMBOL. CONTRACTOR TO INSTALL RACEWAY AND BACKBOX. SEE DETAILS FOR TYPE OF SURFACE RACEWAY AND SIZE OF BACKBOX.

AutoCAD SHX Text EXISTING PAGING SYSTEM MICROPHONE. REMOVE MICROPHONE AND CABLING BACK TO COMM ROOM ORIGINATION POINT. INSTALL BLANK PLATE OVER OPENING. STAINLESS STEEL.

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text X

AutoCAD SHX Text

SEE TC3XX/X

AutoCAD SHX Text zz

AutoCAD SHX Text X

AutoCAD SHX Text

XXXX

AutoCAD SHX Text 2G

AutoCAD SHX Text

TWO-GANG BOX - PROVIDED BY EC

AutoCAD SHX Text

NIC

AutoCAD SHX Text

NOT IN CONTRACT

AutoCAD SHX Text

AC

AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.

AutoCAD SHX Text

PBO

AutoCAD SHX Text

PROVIDED BY OTHERS

AutoCAD SHX Text

AFF

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

PCO-1

AutoCAD SHX Text

PATCH CORD ORGANIZER - 1 UNIT HIGH

AutoCAD SHX Text

AFG

AutoCAD SHX Text

ABOVE FINISHED GROUND

AutoCAD SHX Text

PCO-2

AutoCAD SHX Text

PATCH CORD ORGANIZER - 2 UNITS HIGH

AutoCAD SHX Text

AWG

AutoCAD SHX Text

AMERICAN WIRE GAUGE

AutoCAD SHX Text

PET

AutoCAD SHX Text

PROTECTED ENTRANCE TERMINAL

AutoCAD SHX Text

EMT

AutoCAD SHX Text

EMT TYPE CONDUIT

AutoCAD SHX Text

QTY

AutoCAD SHX Text

QUANTITY

AutoCAD SHX Text

EC

AutoCAD SHX Text

ELECTRICAL CONTRACTOR

AutoCAD SHX Text

PA

AutoCAD SHX Text

PAGING AUDIO SYSTEM

AutoCAD SHX Text

MIC/LINE LEVEL CABLE, 24 AWG. DIGITAL-PLENUM

AutoCAD SHX Text

BELDEN

AutoCAD SHX Text 1801B

AutoCAD SHX Text

18 AWG TWISTED PAIR DISTRIBUTED SPEAKER CABLE -PLENUM

AutoCAD SHX Text

WEST PENN

AutoCAD SHX Text 25224B

AutoCAD SHX Text

14 AWG TWISTED PAIR DISTRIBUTED SPEAKER CABLE -PLENUM

AutoCAD SHX Text

WEST PENN

AutoCAD SHX Text 25226B

AutoCAD SHX Text

12 AWG TWISTED PAIR DISTRIBUTED SPEAKER CABLE -PLENUM

AutoCAD SHX Text

WEST PENN

AutoCAD SHX Text 25227B

AutoCAD SHX Text

UNDERGROUND AUDIO CABLE -14 AWG

AutoCAD SHX Text

WEST PENN

AutoCAD SHX Text

AQ226

AutoCAD SHX Text

CAT-6 UTP CABLES FOR AUDIO/VIDEO CONNECTIVITY SHALL BE BROWN IN COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58756

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 GFI PLATE-STAINLESS HUBBELL SS26 GFI PLATE-STAINLESS HUBBELL SS26 HUBBELL SS26 SS26 1 TWO HOLE GFI PLATE HUBBELL ISF2GY TWO HOLE GFI PLATE HUBBELL ISF2GY HUBBELL ISF2GY ISF2GY 2 CAT-6 CABLES MOHAWK M58756 CAT-6 CABLES MOHAWK M58756 MOHAWK M58756 M58756 2 CAT-6 JACK HUBBELL HXJ6BNCAT-6 JACK HUBBELL HXJ6BNHUBBELL HXJ6BNHXJ6BN

AutoCAD SHX Text

PAGING MIC

AutoCAD SHX Text

46" A.F.F. OR AS FIELD VERIFIED

AutoCAD SHX Text

46" A.F.F. OR AS FIELD VERIFIED

AutoCAD SHX Text

RACEWAYS TO BE INSTALLED ON EXISTING WALL

AutoCAD SHX Text NOTES: 1. WHEN INSTALLING IN A NEW WALL, INSTALL BACKBOX AT WHEN INSTALLING IN A NEW WALL, INSTALL BACKBOX AT CORRECT HEIGHT AND COORDINATE WITH OTHERS. 2. WHEN INSTALLING ON AN EXISTING WALL, INSTALL RACEWAY WHEN INSTALLING ON AN EXISTING WALL, INSTALL RACEWAY FROM THE BOXES TO THE ACCESSIBLE CEILING. INSTALL THRU WALL OR VERTICAL ON WALL.

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1W SURFACE BOX HUBBELL HSB1W HUBBELL HSB1W HSB1W 1 CAT-6 CABLES MOHAWK M58756 CAT-6 CABLES MOHAWK M58756 MOHAWK M58756 M58756 1 CAT-6 JACK HUBBELL HXJ6BNCAT-6 JACK HUBBELL HXJ6BNHUBBELL HXJ6BNHXJ6BN

AutoCAD SHX Text

INTERCOM

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

TP

AutoCAD SHX Text

MW

AutoCAD SHX Text NOTES: 1. HEIGHT IS AT 18" UNLESS OTHERWISE HEIGHT IS AT 18" UNLESS OTHERWISE NOTED ON THE PLANS.

AutoCAD SHX Text 1" CONDUIT WITH A NYLON BUSHING. STUB TO: ABOVE DROP CEILING OR TO BOTTOM OF STRUCTURAL STEEL IN OPEN CEILING AREA TO AN ACCESSIBLE CEILING AREA

AutoCAD SHX Text

1-GANG BACKBOX HUBBELL-BELL #5387-0

AutoCAD SHX Text RACEWAY CODE QTY DESCRIPTION PART # DESCRIPTION PART # PART # 1 SINGLE-GANG BACKBOX, BELL TYPESINGLE-GANG BACKBOX, BELL TYPE

AutoCAD SHX Text NOTES: 1. HEIGHT IS AT 46" UNLESS OTHERWISE HEIGHT IS AT 46" UNLESS OTHERWISE NOTED ON THE PLANS.

AutoCAD SHX Text 3/4" CONDUIT WITH A NYLON BUSHING. STUB TO: ABOVE DROP CEILING OR TO BOTTOM OF STRUCTURAL STEEL IN OPEN CEILING AREA TO AN ACCESSIBLE CEILING AREA

AutoCAD SHX Text

3-GANG BACKBOX HUBBELL-BELL #5390-0

AutoCAD SHX Text RACEWAY CODE QTY DESCRIPTION PART # DESCRIPTION PART # PART # 1 MICROPHONE SEE VALCOMMICROPHONE SEE VALCOM

AutoCAD SHX Text

18" A.F.F. OR AS NOTED ON FLOOR PLANS

AutoCAD SHX Text

COMMUNICATION CABLES

AutoCAD SHX Text

1" CONDUIT EMT TYPE

AutoCAD SHX Text

SURFACE BACKBOX

AutoCAD SHX Text

FACEPLATE

AutoCAD SHX Text

NYLON BUSHING

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

EX

AutoCAD SHX Text

WE

AutoCAD SHX Text

INTERCOM MIC

AutoCAD SHX Text

34" CONDUIT

AutoCAD SHX Text

1" CONDUIT EMT TYPE

AutoCAD SHX Text

DATA

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

DATA

AutoCAD SHX Text

LABEL

AutoCAD SHX Text INSTALLATION NOTES: 1. USE ONLY SECURITY SCREWS WITH THESE PLATES. USE ONLY SECURITY SCREWS WITH THESE PLATES. 2. WHERE NOTED THE CABLES SHALL BE INSTALLED THRU WHERE NOTED THE CABLES SHALL BE INSTALLED THRU SURFACE RACEWAY. 3. LABEL THE FACEPLATE WITH A LASER PRINTED LABELLABEL THE FACEPLATE WITH A LASER PRINTED LABEL

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 GFI PLATE-STAINLESS HUBBELL SS26 GFI PLATE-STAINLESS HUBBELL SS26 HUBBELL SS26 SS26 1 ONE HOLE GFI PLATE HUBBELL ISF1GY ONE HOLE GFI PLATE HUBBELL ISF1GY HUBBELL ISF1GY ISF1GY 1 CAT-6 CABLES MOHAWK M58756 CAT-6 CABLES MOHAWK M58756 MOHAWK M58756 M58756 1 CAT-6 JACK HUBBELL HXJ6BNCAT-6 JACK HUBBELL HXJ6BNHUBBELL HXJ6BNHXJ6BN

AutoCAD SHX Text

MD

AutoCAD SHX Text NOTES: 1. HEIGHT IS AT 18" UNLESS OTHERWISE HEIGHT IS AT 18" UNLESS OTHERWISE NOTED ON THE PLANS.

AutoCAD SHX Text 1" CONDUIT WITH A NYLON BUSHING. STUB TO: ABOVE DROP CEILING OR TO BOTTOM OF STRUCTURAL STEEL IN OPEN CEILING AREA TO AN ACCESSIBLE CEILING AREA

AutoCAD SHX Text

1-GANG BACKBOX HUBBELL-BELL #5387-0

AutoCAD SHX Text RACEWAY CODE QTY DESCRIPTION PART # DESCRIPTION PART # PART # 1 SINGLE-GANG BACKBOX, BELL TYPESINGLE-GANG BACKBOX, BELL TYPE

AutoCAD SHX Text

18" A.F.F. OR AS NOTED ON FLOOR PLANS

AutoCAD SHX Text

COMMUNICATION CABLES

AutoCAD SHX Text

1" CONDUIT EMT TYPE

AutoCAD SHX Text

SURFACE BACKBOX

AutoCAD SHX Text

FACEPLATE

AutoCAD SHX Text

NYLON BUSHING

AutoCAD SHX Text

DATA

AutoCAD SHX Text

LABEL

AutoCAD SHX Text INSTALLATION NOTES: 1. USE ONLY SECURITY SCREWS WITH THESE PLATES. USE ONLY SECURITY SCREWS WITH THESE PLATES. 2. WHERE NOTED THE CABLES SHALL BE INSTALLED THRU WHERE NOTED THE CABLES SHALL BE INSTALLED THRU SURFACE RACEWAY. 3. LABEL THE FACEPLATE WITH A LASER PRINTED LABELLABEL THE FACEPLATE WITH A LASER PRINTED LABEL

AutoCAD SHX Text

ZONE 1

AutoCAD SHX Text

ZONE 4

AutoCAD SHX Text

ZONE 3

AutoCAD SHX Text

CENTRAL CONTROL

AutoCAD SHX Text

BROWN CAT-6 PATCH CABLE

AutoCAD SHX Text

BROWN CAT-6 PATCH CABLE

AutoCAD SHX Text

WF

AutoCAD SHX Text

WG

AutoCAD SHX Text

MIC

AutoCAD SHX Text S

AutoCAD SHX Text

EX

AutoCAD SHX Text

CORE PAGING SYSTEM PROCESSOR/SERVER

AutoCAD SHX Text

VALCOM

AutoCAD SHX Text

VE6030-1

AutoCAD SHX Text

IP TO LINE LEVEL OUTPUT DEVICE. TRANSITIONS FROM NETWORK TO LINE LEVEL

AutoCAD SHX Text

VALCOM

AutoCAD SHX Text

VE8004BR

AutoCAD SHX Text AUDIO AMPLIFIER. TWO OR FOUR CHANNEL. MINIMUM 100 WATTS PER CHANNEL. FOR INTERIOR AND SMALL EXTERIOR HORNS. 4 CHANNEL BRIDGED IS 350 WATTS AT 70 VOLTS. PROVIDE QUANTITY TWO.

AutoCAD SHX Text

QSC

AutoCAD SHX Text

SPA4-100. PROVIDE QUANTITY TWO.

AutoCAD SHX Text

AUDIO AMPLIFIER. TWO CHANNEL. 4 OHM BRIDGED OUTPUT FOR LARGE EXTERIOR HORNS

AutoCAD SHX Text

QSC

AutoCAD SHX Text

SPA2-200

AutoCAD SHX Text

WALL MOUNTED, 4-BUTTON MICROPHONE INTERFACE IP ATTACHED, POE POWERED

AutoCAD SHX Text

VALCOM

AutoCAD SHX Text

VE9894-4-DOC-S

AutoCAD SHX Text

DESKTOP, 4-BUTTON MICROPHONE INTERFACE IP ATTACHED, POE POWERED

AutoCAD SHX Text

VALCOM

AutoCAD SHX Text

VE9893-4-SD

AutoCAD SHX Text

DESKTOP CONSOLE TOUCHPANEL -DESK MOUNT WITH MICROPHONE AND TOUCHPANEL

AutoCAD SHX Text

VALCOM

AutoCAD SHX Text

VE8092

AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS TO MATCH THE CABLE COLOR AND CABLE TYPE BEING TERMINATED. PROVIDE ONE MODULAR JACK FOR EACH CABLE BEING TERMINATED. SEE SPEC AND DRAWINGS FOR COLORS. EQUIP WITH REAR CABLE ORGANIZER

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

PANEL:HPJ24 ORGANIZER:ECMBR3

AutoCAD SHX Text

RACK MOUNT POWER STRIP

AutoCAD SHX Text

TRIPP LITE

AutoCAD SHX Text

RS-1215-RA

AutoCAD SHX Text FLOOR MOUNT CABINET, 24"x32"x84" BLACK CABINET WITH 19" MOUNTING RAILS & 44 RACK UNITS. MESH DOORS, SEE SPECIFICATIONS FOR ADDITIONAL DETAILS.

AutoCAD SHX Text

GREAT LAKES CASE & CABINET COMPANY

AutoCAD SHX Text

GL840E-2432-B-1032MS

AutoCAD SHX Text RACK MOUNT MONITOR ARM. ATTACH TO SIDE OF CABINET OR RACK. MOUNT 21" LCD MONITOR AND CONNECT TO LOCAL PC

AutoCAD SHX Text

SIIG

AutoCAD SHX Text

CE-MT2K12-S1 OR EQUAL

AutoCAD SHX Text

RACK MOUNT KEYBOARD SHELF WITH SLIDE OUT

AutoCAD SHX Text

IANENCLOSURES

AutoCAD SHX Text

RSF1111BK21F4K2

AutoCAD SHX Text 21" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A TABLE TOP MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

LG

AutoCAD SHX Text

22MD4KA-B

AutoCAD SHX Text

RACK MOUNT SHELF. ATTACH TO FRONT RACK RAILS. 14.5" DEEP

AutoCAD SHX Text

MIDDLE ATLANTIC

AutoCAD SHX Text

UFA-14.5

AutoCAD SHX Text

WA

AutoCAD SHX Text

WB

AutoCAD SHX Text

WC

AutoCAD SHX Text

WD

AutoCAD SHX Text

WE

AutoCAD SHX Text

WF

AutoCAD SHX Text

WG

AutoCAD SHX Text

WH

AutoCAD SHX Text

WJ

AutoCAD SHX Text

WK

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

WL

AutoCAD SHX Text

WM

AutoCAD SHX Text

WN

AutoCAD SHX Text

WO

AutoCAD SHX Text

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

472/23434.CTS

AutoCAD SHX Text file no.

AutoCAD SHX Text checked by

AutoCAD SHX Text drawn by

AutoCAD SHX Text consultant

AutoCAD SHX Text issue date

AutoCAD SHX Text index no.

AutoCAD SHX Text contract order no.

AutoCAD SHX Text 59110

AutoCAD SHX Text consultant job no.

AutoCAD SHX Text 1065_115

AutoCAD SHX Text sheet title

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text U

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text P

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text Y24022

AutoCAD SHX Text

PA & PAGING AND COMMUNICATION SYSTEMS UPGRADE

AutoCAD SHX Text

CENTRAL MI CORRECTIONAL FACILITY

AutoCAD SHX Text

ST. LOUIS, MICHIGAN

AutoCAD SHX Text 2/12/24

AutoCAD SHX Text

DESIGN KICK-OFF

AutoCAD SHX Text 3/28/24

AutoCAD SHX Text

50%%% REVIEW

AutoCAD SHX Text 4/25/24

AutoCAD SHX Text

90%%% REVIEW

AutoCAD SHX Text 8/23/24

AutoCAD SHX Text

BID SET

AutoCAD SHX Text 9/04/24

AutoCAD SHX Text

ADD #1

File details come from the government source that posted it. Updated .