415_480V_PUMP_STATION_RACK_FRONT.pdf

PDF 245 KB Posted

Attached to
Pump Station Renewal & Replacement D25 - Phase I
Solicitation number
CC-6690-25/TAD
Issued by
Seminole County, Florida

About this file

This is a technical schematic diagram prepared for the Seminole County Utilities Department, Utilities Engineering Division, depicting the front elevation and plan view of a 480-volt pump station rack assembly for the Pump Station Renewal & Replacement D25 - Phase I project. The diagram illustrates a duplex configuration with three demarcation enclosures (60"H x 36"W x 16"D each), a power monitor enclosure (8"H x 8"W x 6"D) in NEMA 4X stainless steel powder-coated white, rigid aluminum conduit above grade transitioning to Schedule 80 PVC below grade, and associated electrical components including fused and non-fused disconnect switches with conduits to the wet well. The schematic specifies construction requirements such as 40% minimum conduit fill for pump motor conduit (minimum 2" diameter), watertight aluminum hubs, stainless steel 316 posts and channels, grounding and bonding per NEC standards, and corrosion protection for all metallic components. The design requires modification and approval by a Florida licensed professional engineer and is accompanied by related details 411, 412, 416, 418, 421, and 422.

This technical drawing supports the broader Seminole County project (CC-6690-25) with an Engineer's estimate of $3,262,335.00, featuring a mandatory pre-proposal meeting on September 3, 2025, at Sawyer Lake Park and a bid response deadline of September 24, 2025, at 2:00 pm. The project duration is 180 days total, consisting of 160 days to Substantial Completion and 20 days to Final Completion. Qualified bidders must be State of Florida certified general, underground utility, and electrical contractors with demonstrated experience in pump station and lift station renewal, replacement, or rehabilitation. Required insurance coverage includes Workers' Compensation, Commercial General Liability, Business Automobile Liability, Excess/Umbrella Liability, Pollution Liability, and Professional Liability with most limits at $1,000,000 per occurrence. The contract includes liquidated damages of $250 per day for delays and 5% retainage on construction progress payments, with electronic bid submission through the Seminole County website. M/WBEs are encouraged to participate, and prospective bidders are cautioned against contacting county staff other than the designated contact person.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPD

FUSED DISC.METER

PCP

(60"Hx36"Wx16"D)

RESERVED

FOR ATS

DEMARCATION ENCLOSURE

(TYP 3 FOR DUPLEX)

M

IN

. 3 6"

O R

AS

R

EQ

. B

Y C

O D

E O

R W

IN

D

L O

AD

PLAN VIEW

NON-FUSED

DISC.

FRONT ELEVATION

CONDUITS TO

WET WELL

NOTES:

1. THIS DIAGRAM IS NOT PROJECT SPECIFIC. A DIAGRAM SHALL BE MODIFIED AND APPROVED BY A FLORIDA LICENSED

PROFESSIONAL ENGINEER

2. DETAILS 415, 416, 418, 421, & 422 ARE A SET AND ACCOMPANY EACH OTHER.

3. PUMP MOTOR CONDUIT SHALL BE SIZED TO ACCOMMODATE 40% CONDUIT FILL, MINIMUM SIZE SHALL BE 2".

4. GROUNDING AND BONDING SYSTEM SHALL BE INSTALLED AS PER THE NEC, REF. DETAILS 411 & 412.

5. RIGID ALUMINUM CONDUIT SHALL BE USED ABOVE GRADE, TRANSITION TO PVC SCH 80 BELOW GRADE OR SLAB.

6. PROVIDE CORROSION PROTECTION AT ALL METALLIC CONDUIT AND POSTS SET IN CONC. OR DIRECT BURIED.

WATERTIGHT ALUM.

HUB (TYP)

RIGID ALUM. CONDUIT,

TYP ABOVE GRADE

TRANSITION TO

SCH 80 PVC BELOW

GRADE OR SLAB

PROVIDE CLEAR

ACCESS TO GEN.

RECEPTICAL

" M

AX

M

IN

PCP

(60"Hx36"Wx16"D)

DEMARCATION

ENCLOSURE

(TYP 3 FOR

DUPLEX)

P1 P2LI/PI

3" STAINLESS STEEL

316 POST (TYP)

1-1/2" STAINLESS STEEL

316 CHANNEL WITH

STAINLESS STEEL "U"

BOLTS, LOCK WASHERS

AND NUTS (TYP)

STAINLESS STEEL CAP

OR PLUG (TYP)

" M

IN

" M

AX

M

IN

TYPE EYSR

SEAL-OFFS (TYP)

PANEL & RACK

GROUNDING

PM

POWER MONITOR ENCLOSURE

POWER MONITOR

ENCLOSURE

(8"Hx8"Wx6"D)

NEMA 4X STAINLESS STEEL

POWDER COATED WHITE

NEMA 4X STAINLESS STEEL

POWDER COATED WHITE

DATE:

FIGURE:

SEMINOLE COUNTY UTILITIES DEPARTMENT - UTILITIES ENGINEERING DIVISION

480V PUMP STATION RACK FRONT

XX/XX/XX

alaforce Architect

Sheets and Views
415 480V PUMP STATION RACK FRONT

File details come from the government source that posted it. Updated .