4-BUILDING AND CURTAIN DETAILS.pdf

PDF 841 KB Posted

Attached to
26B-029 BIOSOLIDS BUILDING PVC CURTAIN INSTALLATION
Solicitation number
26-029
Issued by
Marion County, Florida

About this file

This is a building and curtain details plan document prepared by Ardurra Group, Inc., the civil engineer for Marion County Board of County Commissioners Utilities Division, depicting the installation specifications for PVC coated vinyl curtains around the biosolids dewatering building at the Southwest Regional Water Reclamation Facility in Marion County, Florida. The project involves the installation of industrial roller curtains on all four sides of an existing building structure measuring approximately 19 feet by 19 feet, with curtain coverage extending 37 feet 11.75 inches in height on the north and south elevations and varying dimensions on the east and west elevations. The curtains shall be constructed of 18-ounce fire-retardant PVC coated vinyl with Velcro seams, mounted to existing ceiling and structural elements using steel roller track systems and concrete anchors spaced at five-foot intervals or closer per manufacturer specifications. The south and east curtain faces shall be solid with no clear windows, while the north and west faces may include window installations. The contractor is required to perform field measurements prior to ordering curtains and to coordinate curtain color selection with the owner from the manufacturer's available options.

The plans specify that concrete anchors shall be low-profile Tapcon anchoring screws or equivalent, with manufacturer-provided anchoring systems permitted as substitutes. All bolts and hardware must comply with manufacturer requirements, and ceiling roller track mounts shall be installed according to manufacturer spacing specifications. The document does not include pricing information, contract values, performance timelines, or procurement schedule details, as it functions solely as technical design guidance for the curtain installation project. The project site contact is Joshua Kramer, Utilities Deputy Director at Marion County Utilities Division, located in Belleview, Florida, and the civil engineer contact is Chuck A. Pigeon, P.E., at Ardurra Group, Inc. in Ocala, Florida.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TOP VIEW OF BUILDING

'-0

'-0

'-0

'-0

19'-5" 18'-5"

19'-5" 18'-5"

EXISTING ELECTRICAL CONDUIT

EXISTING RECLAIM

WATER MAIN

SANITARY SEWER DRAIN

EXISTING RECLAIM WATER

MAIN

(3) EXISTING 4" FLEXIBLE HOSE

CONNECTIONS

EXISTING FDOT TYPE

"C" INLET

EXISTING CONTROL PANEL

PROPOSED

CURTAIN (TYPICAL

FOUR SIDES)

EXISTING ELECTRICAL

CONDUITS TO REMAIN

VELCRO SEAM VELCRO SEAM

VELCRO SEAM

VELCRO SEAM

EXISTING GUTTER

DOWNSPOUT AND

SPLASHPAD TO REMAIN

TYPICAL EACH COLUMN

CO

N

CR

ET

E

DR

IV

EW

AY

CO

N

CR

ET

E

DR

IV

EW

AY

5'-0" CONCRETE ANCHOR EVERY 5' O.C.

MIN. OR MORE FREQUENT PER

MANUFACTURER REQUIREMENTS

NORTH/SOUTH VIEW

8' -9

1 4" 5'

-0

TOP OF CONCRETE SLAB

RAIN GUTTER

DOWNSPOUT TYP.

37'-113 4"

3.

0"

3' -1

1" 1.

0"

'-8

1 4"

STEEL ROLLER TRACK

BOTTOM OF

ROOF SIDING

CEILING TRACK MOUNT SPACED

PER MANUFACTURER

REQUIREMENT

VELCRO SEAM

LOWER 9' OF CURTAIN

C-BEND

BUILDING

SUPPORT

METAL

SUPPORT

BEAM

TOP OF

ROOF

FRONT

CURTAIN

TYPICAL CORNER DETAIL

CEILING

TRACK MOUNT

EX.

CONCRETE

BASE

VELCRO

STRAP

SIDE

CURTAIN

STEEL

ROLLER

TRACK

EAST/WEST VIEW

TOP OF CONCRETE SLAB

EXISTING BOLLARD (TYP)

5'-0"

8' -9

5'

-0

3' -1

1" 3.

0" 1.

0"

'-8

VARIES SEE PLAN VIEW VARIES SEE PLAN VIEW

STEEL ROLLER TRACK

BOTTOM OF ROOF SIDING

CIELING TRACK MOUNT SPACED

PER MANUFACTURER

REQUIREMENTS

VELCRO SEAM

LOWER 9' OF CURTAIN

CONCRETE ANCHOR EVERY 5' O.C.

MIN. OR MORE FREQUENT PER

MANUFACTURER REQUIREMENTS

SR

CR 484Ju ly

0, T

:\2

M ar io n

C ou nt y\

_O ak R un W

W

TP

B uf fe r\

D W

G \C

-C U

R T-

D

TL

S .d w g

O ct ob er

, 2

T :\2

M ar io n C ou nt y\

_O ak

R un

W W

TP

B uf fe r\ D

W G

\C -C

U R

T- D

TL

S

.d w g

A

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

EXHIBIT 1

100% PLANS

09/19/2025

B

IO

S O

LI

D

S D

E W

A

TE

R

IN

G B

U

IL

D

IN

G C

U R

TA

IN

D E

TA

IL

S

S O

U

TH

W E

S T

R E

G

IO

N A

L W

R F

B

IO

S O

LI

D

S B

U

IL

D

IN

G C

U R

TA

IN

S

N O

D

A

TE

R E

V

IS

IO

N

B Y

JOB NO:

925 S.E. 17th Street

Suite A

Ocala, Florida 34471

Phone: (352) 861-7799 www.Ardurra.com

2025-1116-00

Utilities 11800 S. U.S. Highway 441

Belleview, FL 34420

Phone: 352-307-6000 Fax: 352-307-6001

After hours: 352-307-6000

NOTES:

1. ALL CONCRETE ANCHORS SHALL BE LOW PROFILE TO THE CONCRETE SURFACE. MANUFACTURER PROVIDED ANCHORING SYSTEM

MAY BE SUBSTITUTED FOR CONCRETE ANCHOR DETAIL PROVIDED BELOW.

2. BOLTS TO BE USED SHALL BE IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS.

3. CURTAIN MATERIAL SHALL BE 18 OZ. PVC COATED VINYL (FIRE RETARDANT).

4. COLOR OF CURTAIN TO BE SELECTED BY THE OWNER. CONTRACTOR TO PROVIDE MANUFACTURER'S COLOR SELECTIONS.

5. SOUTH AND EAST CURTAIN FACES SHALL BE SOLID CURTAIN WITH NO CLEAR WINDOW.

6. DIMENSIONS PROVIDED ARE FOR THE CURTAIN COVERAGE AREA. ADDITIONAL CURTAIN FABRIC OR REDUCTIONS FOR MOUNTING

HARDWARE MAY BE REQUIRED.

7. CONTRACTOR TO FIELD MEASURE DIMENSIONS PRIOR TO ORDERING CURTAINS.

CEILING MOUNT DETAIL

EXISTING METAL OVER HANG

EXISTING SIDE OF ROOFING

INSTALL CEILING ROLLER

TRACK MOUNT (TYP.)

PROJECT

SITE

OWNER:

CONTACTS

CIVIL ENGINEER:

ARDURRA GROUP, INC.

925 SE 17TH ST., SUITE 'A'

OCALA, FL 34471

CONTACT: CHUCK A. PIGEON, P.E.

PHONE: (352) 861-7799

MARION COUNTY BOARD OF COUNTY COMMISSIONERS

11800 SE US HWY 441

BELLEVIEW, FLORIDA 34420

CONTACT: JOSHUA KRAMER

UTILITIES DEPUTY DIRECTOR

PHONE: (352) 307-6000

SOUTHWEST REGIONAL WRF

BIOSOLIDS BUILDING CURTAINS

MARION COUNTY

UTILITIES DIVISION

LOCATION: MARION COUNTY, FLORIDA

SECTION 35 TOWNSHIP 16 SOUTH, RANGE 20 EAST

CONCRETE ANCHOR DETAIL

CURTAIN FABRIC WITH GROMMETS

SPACED PER MANUFACTURER STANDARDS

INDUSTRIAL ROLLER

CURTAIN HOOKS

CURTAIN FABRIC WITH GROMMETS

SPACED PER MANUFACTURER STANDARDS

2-5/16" D-RING 316 SS

1/4"X3" STEEL HEX HEAD CONCRETE ANCHORING

SCREWS TWO PER ANCHOR, TAPCON OR EQUIVALENT

ALIGN CONCRETE ANCHORS WITH CURTAIN DRAPE AT

GROMMET LOCATIONS, SPACED 5' O.C. MINIMUM

SNAP HOOK CARABINER

3" T

YP

IC

AL

File details come from the government source that posted it. Updated .