4-Attachment J Provided Parts Accessible.docx
DOCX document 12 KB Posted
- Solicitation number
- GJ26-156
- Issued by
- Juab County, Utah
About this file
This is a Provided Parts Accessible document for the Utah Communications Authority (UCA) related to the GJ26-156 Parker Mountain Radio Tower and Shelter Installation project located at Parker Range in Piute County, Utah (coordinates 38.324602, -111.892773). The project involves the installation of a radio tower and shelter at a state trust lands site. Questions regarding the solicitation are due by May 29, 2026, no later than 10:00 AM Mountain Time, submitted via U3P. Bids are due by June 4, 2026, no later than Noon Mountain Time, also via U3P. The document specifies that file uploads are limited to 1GB per single file to ensure compliance with submission requirements.
The UCA is the issuing office for all bidding documents, and this solicitation is posted as a courtesy advertisement only, with the actual contract award decisions managed directly by the UCA rather than through the Division of Purchasing. Vendors are responsible for reviewing the complete solicitation to ensure full compliance with all stated requirements. The solicitation will be canceled upon the closing date, though submitted bids will continue to be evaluated according to the criteria outlined in the solicitation documents. Interested bidders should contact the designated individual or office identified in the full solicitation for additional information regarding pricing terms, funding sources, and other contract-specific details.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment J — List of UCA Provided Parts Parker Mountain Communications Tower Site The following parts and materials are provided by the Utah Communications Authority (UCA) and are to be picked up by the awarded contractor from the UCA warehouse prior to mobilization to the Parker Mountain site. Items marked with an asterisk (*) in the original source are noted in the corresponding list item below.
Shelter and Mechanical Equipment
1. One (1) 23 feet 1 inch by 11 feet 1.5 inches by 9 feet 2 inches modular and palletized two-room Enviro brand communications shelter. (Marked with asterisk in source.)
1. One (1) Gree mini-split HVAC unit. (Marked with asterisk in source.)
1. One (1) standard 19-inch equipment rack. (Marked with asterisk in source.)
1. Generator intake and exhaust ducting.
1. One (1) 35 kW Generac generator and stands.
Microwave and Radio Frequency Equipment
1. One (1) pre-assembled 4-foot High Performance Microwave antenna with radios attached. (Marked with asterisk in source.)
1. LMR cable, connectors, ground kits, polyphasers, and mounting cushions and hardware for the microwave installation.
1. Two (2) DB Spectra Omni antennas, model DS7C09P36U2D. (Marked with asterisk in source.)
1. One (1) Combilent tower-top amplifier. (Marked with asterisk in source.)
Fuel System Components
1. One (1) 1,000-gallon propane tank. (Marked with asterisk in source.)
1. Two (2) prefabricated 4-foot by 4-foot propane tank pads. (Marked with asterisk in source.)
Primary Fuel Regulator Specifications One (1) primary fuel regulator with the following specifications (item marked with asterisk in source):
1. MEC Type: MEGR-1622H-JGJ.
1. Body: FPOL by three-quarter-inch NPT.
1. Orifice: seven thirty-seconds of an inch (7/32 inch).
1. SPG Range: 8.0 to 12.0 PSI.
Solar Power System
1. Thirty-six (36) solar panels.
1. Aluminum mounting bracket kits for three sectors, ballast style.
1. Pipe and support brackets for three sectors.
1. Three (3) photovoltaic (PV) junction boxes.
Permits and Grounding
1. United States Forest Service (USFS) issued Right-of-Way (ROW).
1. Two (2) 20-inch ground bus bars. (Marked with asterisk in source.)
Tower Components The following tower components are provided (full set marked with asterisk in source unless otherwise noted):
1. Complete tower steel and hardware.
1. Construction step bolts (see notes in original specifications).
1. Inside climbing ladder, 16 inches wide.
1. Waveguide support ladder sized to support all transmission lines.
1. One (1) 3-foot sidearm with two (2) tiebacks and one (1) 5-foot mounting pipe at the 96-foot elevation.
1. One (1) 3-foot sidearm with two (2) tiebacks and one (1) 5-foot mounting pipe at the 76-foot elevation.
1. One (1) 4-and-one-half-inch outside-diameter (O.D.) leg dish mount at the 40-foot elevation.
1. One (1) 4-foot ice shield.
1. Tuf-Tug 150-foot safety climb system without harness.
1. Waveguide bridge, two-leg, 2 feet by 10 feet, 15 feet direct burial, with three (3) 3-level trapeze kits.
1. 2 and seven-eighths inch by 15-foot lightning rod extension.
1. Three (3) tinned bus bars, one-quarter inch by 2 inches by 12 inches, each with 26 holes.
1. Three (3) weld-on grounding tabs.
1. 10-foot by three-quarter-inch lightning rod, copper-clad, with stiffener.
1. Professional Engineer (P.E.) certified tower profile and foundation drawings.
1. Final erection drawings.
Document Notes Asterisk notation: In the original Attachment J source document, items marked with a leading asterisk (*) denote parts that are individually identified in the UCA warehouse pick-list. The asterisk has been preserved in descriptive form in this accessible version. The descriptive labeling does not alter the scope of provided materials.
Accessibility statement: This document has been formatted for compatibility with screen readers and other assistive technologies. The structure follows Web Content Accessibility Guidelines (WCAG) 2.1 Level AA. Headings use proper outline levels, lists use semantic list formatting, and all measurements are expressed in plain language to support assistive-technology pronunciation.
Attachment J — Parker Mountain Provided Parts — Page of
File details come from the government source that posted it. Updated .