2-ATTACHMENT B - SITE LAYOUT AND SHELTER DETAIL.pdf
PDF 795 KB Posted
- Solicitation number
- GJ26-156
- Issued by
- Juab County, Utah
About this file
This is a site layout and shelter detail document for the Utah Communications Authority's Parker Mountain Radio Tower and Shelter Installation project located on State Trust Lands in Parker Range, Piute County, Utah (GPS coordinates: 38.324602, -111.892773). The document provides technical specifications and architectural drawings for a telecommunications shelter installation, including detailed dimensions for equipment rack placement, HVAC systems (both internal and external), ducting, PV junction boxes, antenna grounding systems, LP fuel lines, solar conduits, and bus bar configurations. Questions regarding the solicitation are due by May 29, 2026, no later than 10:00 AM Mountain Time, with submissions due by June 4, 2026, no later than Noon Mountain Time, both to be submitted via U3P.
The layout drawings specify precise measurements for shelter dimensions (60 feet length with various width specifications), equipment spacing, and external utility placements. The document includes grounding system conduit routing, LP sensor conduit locations, and Andrew PN 252138 antenna specifications with a 20-inch bus bar. HVAC clearances of 5 feet 9 inches to 5 feet 13.75 inches are designated, with finished floor heights of 4 feet 2 inches and 1 foot 8 inches noted. The document serves as a technical reference for bidders to understand the physical infrastructure requirements and spatial constraints for the radio tower and shelter installation project.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Parker Mountain 5-18-26
Ducting
DUCTING
Rack
8'-5"
20'-3"
12'-0" 12'-0"
60'-0"
7'-4" 2
Rack
P25
R1
In t.
H
V A
C
C e n te re d
2'-0"
11'-9"
5'-8"
5'-8"
5'-8"
3'-2" 3'-2" 3'-2"
5'-8"
5'-8"
5'-8"
3'-2" 3'-2" 3'-2"
20'-3"
'-2
1'-10"
E x te rn a l H V
A C
E x te rn a l H V
A C
17'-0"
'-1
/4
7'-4"
PV
Junction
PV
Junction
PV
Junction
Andrew
PN 252138
Andrew
PN 252138
20" Bus Bar
23'-1"11'-1 1/2" 11'-1 1/2"
Conduit To Grounding System
North
8'-5"
South
LP Fuel Line
EastWest
'-1
HV
AC
Parker Mountain
5'-4"
Solar Conduits
'-1
/2 A
F F
'2
A
F F
1'-8"
LP Sensor Conduit
External HVACExternal HVAC
1'-6" 1'-6"
| Parker Draft 2, 3-13-26.vsdx |
| Site Layout |
| Shelter |
| Antenna & Tower |
| Grounding |
| Page-5 |
| Blank Page |
File details come from the government source that posted it. Updated .