4-Attachment D Plans.pdf
PDF 8 MB Posted
- Attached to
- UDOT Brigham City MS4 Project Upgrade
- Solicitation number
- UDOT260198CN
- Issued by
- Utah
About this file
This is a construction planning document prepared by Horrocks Engineers for the Utah Department of Transportation (UDOT) Brigham City Maintenance Site Improvements project located in Box Elder County. The project encompasses demolition and reconstruction of site facilities including an evaporative pond, wash rack, sander storage rack, and associated infrastructure. Construction work includes new asphalt paving, an elevated wash rack structure with concrete foundations, a material storage bin with concrete slab and divider walls, an 11-bay sander storage rack with steel frame construction, and a brine-mixing vault with concrete walls and mat foundation. Earthwork involves pond excavation, site re-grading, base material placement, and subgrade preparation. Utility improvements include new stormwater inlets, catch basins, and storm drain piping; water supply lines with yard hydrants and above-grade wash rack piping; and sanitary sewer piping with manholes and treatment structures. The comprehensive construction drawings include site and horizontal plans, utility plans, grading and drainage plans, erosion control plans, and detailed structural specifications for all proposed improvements. A mandatory virtual pre-bid meeting is scheduled for March 31, 2026 at 2:00 PM. Project completion is required by June 15, 2026.
The awarded contractor must submit performance and payment bonds upon contract award. UDOT reserves the right to evaluate bidder responsibility based on previous MS4 project performance, specifically requiring that prior projects be completed without excessive delays or warranty issues and that no current MS4 projects be in liquidated damages status. The contract will be awarded to the lowest responsive and responsible bidder as a single contract award. Construction specifications reference UDOT Standards and Specifications (2017), Brigham City Corporation Public Works Standards (3rd Edition, July 2005), and APWA Standard Plans (2017 Edition), with field survey of existing utilities and conditions conducted in August 2019. The project site is located at 60 Power Plant Road, Brigham City, Utah 84302, with portions within the FEMA 100-year floodplain zone and encompassing a PFOA wetland as defined by the U.S. Fish and Wildlife Service along Box Elder Creek.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-Attachmnet B Standard Specifications.pdf | ||
| 5-Attchment C Bid sheet.xlsx | XLSX spreadsheet | |
| 2-7. Submittal Form- Vendor Set Up Form 2024-06-27 .pdf | ||
| 1-2. Attachment A- Standard Terms and Conditions- with check fields- 09-16-2024 2.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S. Standard Units (Inch-Pound Units)
ALL UNITS IN FEET UNLESS
OTHERWISE NOTED
UTAH DEPARTMENT OF TRANSPORTATION
SHEET
NO.
REGION ONE PRECONSTRUCTION ENGINEER
DESIGN ENGINEER
VERIFIED FOR SUBMISSION FOR ADVERTISEMENT
APPROVED FOR ADVERTISEMENT
APPROVED FOR USE
(TITLE), (LOCAL GOVERNMENT)
VICINITY MAP
ARIZONA
WYOMING
IDAHO
C O
LO
R
AD
ON
EV
AD
A
I-1
I-1
I-70
I-7
6-50
40I-80
I-80
I-8
BOX ELDER CACHE RICH
WEBER
MORGAN
DAVIS
TOOELE
SALT LAKE
UTAH
WASATCH
SUMMIT DAGGETT
DUCHESNE
UINTAH
CARBON
JUAB
MILLARD
BEAVER
IRON
WASHINGTON KANE
GARFIELD
PIUTE WAYNE
EMERY
GRAND
SAN JUAN
SANPETE
SEVIER
SITE DEVELOPMENT IMPROVEMENT PLANS
FOR
UTAH DEPARTMENT OF TRANSPORTATION
STATE FUNDED PROJECT
BRIGHAM CITY MAINTENANCE SITE IMPROVEMENTS
BOX ELDER COUNTY
60 POWER PLANT RD, BRIGHAM CITY, UT 84302
PROJECT NUMBER PIN: TBD
BRIGHAM CITY SITE
SITE
200 SOUTH
EA
ST
US HWY 89
U S
H W
Y
BRIGHAM
CITY
SHEET INDEX
PAGE # SHEET # DESCRIPTION
1 G-1 COVER
2 G-2 NOTES & CONTACTS
3 G-3 NOTES
4 G-4 LEGEND
5 EX-1 EXISTING CONDITIONS
6 DM-1 DEMOLITION PLAN
7 CS-1 SITE & HORIZONTAL PLAN
8 CS-2 SITE & HORIZONTAL PLAN
9 CU-1 UTILITY PLAN
10 CG-1 GRADING & DRAINAGE PLAN
11 CG-2 WASH RACK ENLARGED PLAN
12 EC-1 EROSION CONTROL PLAN
13 DT-1 DETAILS
14 DT-2 DETAILS
15 DT-3 DETAILS
16 DT-4 DETAILS
17 DT-5 DETAILS
18 DT-6 DETAILS
19 DT-7 DETAILS
SHEET INDEX
PAGE # SHEET # DESCRIPTION
20 DT-8 EROSION CONTROL DETAILS
21 DT-9 EROSION CONTROL DETAILS
22 DT-10 EROSION CONTROL DETAILS
23 S0.1 GENERAL NOTES
24 S0.2 GENERAL DETAILS
25 S1.0 FOUNDATION PLAN
26 S1.1 FOUNDATION MATERIAL BINS
27 S1.2 WASH RACK PLAN
28 S1.3 SANDER RACK PLAN
29 S1.4 BRINE VAULT PLAN
30 S2.0 FOUNDATION DETAILS
31 S2.1 FOUNDATION DETAILS II
32 S2.2 MATERIAL BIN DETAILS
33 S2.3 WASH RACK DETAILS
34 S2.4 WASH RACK DETAILS II
35 S2.5 WASH RACK DETAILS III
36 S2.6 WASH RACK DETAILS IV
37 S2.7 SANDER RACK DETAILS
38 S2.8 BRINE VAULT DETAILS
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Au gu st
, 2
7/21/21
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
1. ALL CONSTRUCTION SHALL COMPLY WITH THE STANDARD DRAWINGS AND SPECIFICATIONS OF THE GOVERNING JURISDICTIONAL ENTITY(IES) FOR THIS PROJECT, UNLESS OTHERWISE NOTED.
SEE PROJECT SPECIFICATIONS AND STANDARDS SECTION ON THIS SHEET FOR MORE
INFORMATION.
2. THE CONTRACTOR SHALL KEEP ON SITE AT ALL TIMES A COPY OF THE APPROVED AND STAMPED
CONSTRUCTION PLANS ON WHICH IS RECORDED THE ACTUAL LOCATIONS OF THE CONSTRUCTED
UTILITIES AND ANY OTHER UTILITIES ENCOUNTERED. THE CONTRACTOR SHALL PROVIDE THESE
LOCATIONS TO THE DESIGN ENGINEER.
3. THE CONTRACTOR(S) SHALL REMOVE ALL OBSTRUCTIONS, BOTH ABOVE AND BELOW GROUND, AS
REQUIRED FOR THE CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. THIS SHALL INCLUDE
CLEARING AND GRUBBING WHICH CONSISTS OF CLEARING THE GROUND SURFACE OF ALL TREES, STUMPS, BRUSH, UNDERGROWTH, HEDGES, HEAVY GROWTH OF GRASS OR WEEDS, FENCES, STRUCTURES, DEBRIS, RUBBISH, AND SUCH MATERIAL WHICH IN THE OPINION OF THE ENGINEER, IS UNSUITABLE FOR THE FOUNDATION OF PAVEMENTS. ALL MATERIAL NOT SUITABLE FOR FUTURE
USE ON SITE SHALL BE DISPOSED OF OFF SITE.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK AND BETWEEN TRADES.
SUB-CONTRACTORS ARE ALSO RESPONSIBLE FOR COORDINATION WITH OTHER TRADES AND
DISCIPLINES INCLUDED IN THE CONTRACT DOCUMENTS. IF ANY DISCREPANCIES ARE FOUND, THE
GENERAL CONTRACTOR IS TO NOTIFY ENGINEER IMMEDIATELY BEFORE COMMENCEMENT OF
WORK. NO EXTRA COSTS TO THE PROJECT WILL BE INCURRED DUE TO FAILURE OF GENERAL
CONTRACTOR AND/OR SUB-CONTRACTORS TO REVIEW CONTRACT DOCUMENTS AND COORDINATE
WITH OTHER TRADES.
5. ALL TRAFFIC CONTROL SHALL CONFORM TO THE MOST RECENT VERSIONS OF THE MANUAL OF
UNIFORM TRAFFIC CONTROL DEVICES AND LOCAL CITY STANDARDS.
6. THE CONTRACTOR MUST OBTAIN A PERMIT FROM THE BUILDING DEPARTMENT FOR ANY WALLS
GREATER THAN 4' IN HEIGHT CONSTRUCTED WITHIN THE PROJECT. ALL ROCK WALLS
CONSTRUCTED WITHIN THE PROJECT MUST BE CERTIFIED AND INSPECTED BY A LICENSED
STRUCTURAL ENGINEER PRIOR TO THE CITY'S FINAL ACCEPTANCE.
7. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT OVERHEAD POWERLINES EXIST ON THE
PROJECT SITE. ALL CARE AND CAUTION IS TO BE EXERCISED TO ENSURE THE SAFETY OF
PERSONS AND PROPERTY AROUND THE POWERLINES.
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING
UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE CONTACTED IMMEDIATELY, PRIOR TO
ANY FURTHER WORK BEING DONE RELATED TO THE ISSUE.
CAUTION: NOTICE TO CONTRACTOR
USE OF THE INFORMATION CONTAINED IN THIS INSTRUMENT FOR OTHER THAN THE SPECIFIC PURPOSE FOR WHICH IT WAS INTENDED AND FOR OTHER THAN THE CLIENT FOR WHOM IT WAS PREPARED IS FORBIDDEN UNLESS EXPRESSLY PERMITTED IN WRITING IN ADVANCE TO HORROCKS ENGINEERS, AND HORROCKS ENGINEERS SHALL HAVE NO LIABILITY TO ANY USE OF THIS INFORMATION WITHOUT THEIR
WRITTEN CONSENT.
LEGAL NOTICE TO CONTRACTOR
PROJECT SPECIFICATIONS AND STANDARDS
1. UTAH DEPARTMENT OF TRANSPORTATION (UDOT) STANDARDS & SPECIFICATIONS 2017
2. BRIGHAM CITY CORPORATION PUBLIC WORKS STANDARDS 3RD ED., JULY 2005
3. APWA STANDARD PLANS 2017 ED.
4. FIELD SURVEY OF EXISTING UTILITIES & CONDITIONS CONDUCTED AUGUST 2019, BY
HORROCKS ENGINEERS.
1. HORROCKS ENGINEERS HAS PREPARED GRADING PLANS TO CONTAIN THE RUNOFF AS REQUIRED BY THE JURISDICTIONAL ENTITY. SEE PROJECT SPECIFICATIONS AND STANDARDS SECTION ON THIS
SHEET FOR MORE INFORMATION.
2. IT IS UDOT'S RESPONSIBILITY TO COMPLETE AND MAINTAIN THE FINAL GRADING ON THEIR
PROPERTY IN ACCORDANCE WITH THE DRAINAGE CONCEPT IDENTIFIED IN THE GRADING AND
DRAINAGE PLAN. THE PROPERTY OWNER IS RESPONSIBLE, IN PERPETUITY, FOR INSPECTING AND
MAINTAINING PROPER DRAINAGE DURING CONSTRUCTION AND WHEN RE-GRADING OR MAKING
MODIFICATIONS TO DRAINAGE FACILITIES THAT AFFECTS THEIR PROPERTY.
3. THE GRADING AND DRAINAGE PLANS DO NOT IDENTIFY THE CONSTRUCTION METHODS, EQUIPMENT, PROCEDURES, AND OR SEQUENCING TO BE EMPLOYED BY THE CONTRACTOR. ALL GRADING
OPERATIONS INCLUDING BUT NOT LIMITED TO SITE PREPARATION, SCARIFICATION, EXCAVATION, OVER-EXCAVATION, PLACEMENT OF FILLS, AND COMPACTION OF FILLS, SHALL BE PERFORMED BY
THE CONTRACTOR IN CONFORMANCE WITH THE PROJECT SPECIFICATIONS AND STANDARDS
SECTION ON THIS SHEET.
4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY HORROCKS ENGINEERS IMMEDIATELY IF THERE ARE ANY CONFLICTS BETWEEN THE REQUIREMENTS OF THE GRADING AND DRAINAGE PLANS
AND ANY FIELD OBSERVATIONS.
5. THE CONTRACTOR SHALL MAINTAIN ALL EXISTING DRAINAGE FACILITIES WITHIN THE
CONSTRUCTION AREA UNTIL THE DRAINAGE IMPROVEMENTS ARE IN PLACE AND FUNCTIONAL.
6. THE CONTRACTOR SHALL PROVIDE SUITABLE METHODS & EQUIPMENT TO CONTROL DUST AND AIR
POLLUTION CAUSED BY CONSTRUCTION OPERATIONS. THE CONTRACTOR SHALL ALSO PROVIDE
SUITABLE MUD AND DIRT CONTAINMENT TO MAINTAIN THE WORK SITE, ACCESS ROADWAYS, AND
ADJACENT PROPERTIES IN A CLEAN CONDITION.
7. ALL EXCAVATION AND GRADING SHALL BE IN ACCORDANCE WITH THE CURRENT REQUIREMENTS OF
THE JURISDICTIONAL ENTITIES.
8. PRIOR TO CONSTRUCTION, AN EROSION AND SEDIMENT CONTROL PLAN WILL BE SUBMITTED TO THE
UDOT STORMWATER COORDINATOR FOR APPROVAL.
GRADING & DRAINAGE NOTES
GENERAL NOTES
CATV SERVICE & TELEPHONE POWER
BEAR RIVER WATER C.D.
102 WEST FOREST STREET
BRIGHAM CITY, UT 84302
435-723-7034
JILL JEPPSEN
JILLJ@BRWCD.COM
WATER
UTILITY CONTACTS
WATER
1. RAISE ALL UTILITIES, SUCH AS MANHOLES, METER SETTERS, FIRE HYDRANTS, WATER VALVE LIDS, ETC. TO ROADWAY OR PROJECT FINISHED GRADE AS MAY BE APPLICABLE.
2. 12 GAUGE COPPER LOCATE WIRE SHALL BE TAPED TO ALL WATER LINES FOR LOCATION PURPOSES.
THE WIRE SHALL BE BROUGHT UP AT EACH VALVE BOX AND HYDRANT.
3. ALL REMOVED EXISTING WATER UTILITIES SHALL EITHER BE SALVAGED OR PROPERLY DISPOSED
OF ACCORDING TO GOVERNING REGULATIONS.
SEWER
1. ALL NEW SEWER SYSTEMS WILL BE MANDREL AND AIR TESTED.
2. SEWER LENGTHS AND SLOPES ARE MEASURED FROM CENTER-CENTER OF MANHOLES.
3. ALL REMOVED EXISTING SEWER UTILITIES SHALL EITHER BE SALVAGED OR PROPERLY DISPOSED
OF ACCORDING TO GOVERNING REGULATIONS.
POWER
1. CONTRACTOR TO FOLLOW ALL BLUE STAKES PROTOCOLS.
2. ANY ELECTRICAL DESIGN WORK REQUIRED SHALL BE PERFORMED BY A LICENSED ELECTRICAL
ENGINEER UNLESS OTHERWISE CONVEYED AS NOT REQUIRED BY THE LOCAL ENERGY SERVICES.
3. ACCESS TO EXISTING ELECTRICAL EQUIPMENT MUST BE MAINTAINED THROUGHOUT THE PROJECT.
4. CONTACT LOCAL ENERGY SERVICES FOR ANY REQUIRED CHANGES OR CONFLICTS WITH EXISTING
ELECTRICAL INFRASTRUCTURE.
5. CHANGES MADE TO EXISTING INFRASTRUCTURE WILL BE DONE TO THE LOCAL ENERGY SERVICES
STANDARDS AND COMPLETED BY A PRE-QUALIFIED CONTRACTOR OR ENERGY SERVICES.
UTILITY NOTES UTILITY NOTES
Know what's below.
Call before you dig.
R
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
G-2
N O
TE
S
C
O N
TA
C
TS
FRONTIER COMMUNICATIONS
435-257-8110
MIKE GILES
ROCKY MOUNTAIN POWER
503-813-6993
LINDY PALMBERG
DOMINION ENERGY
801-324-3970
JOHN STAPLES
JOHN.STAPLES@DOMINIONENERGY.COM
GAS FIBER
CENTURY LINK
801-974-8181
TERESA HINTON
BRIGHAM CITY, STORM, SEWER
BUILDING DEPARTMENT
20 NORTH MAIN
BRIGHAM CITY, UT 84302
435-734-6628
TRACY HALLADAY
THALLADAY@BCUTAH.ORG
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, 7/21/21
7/
/2
JS
B
JO
SH
U A
S.
B
LA
C
K
R
EA
D Y
TO
B
ID
S
ET
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
EROSION CONTROL NOTES
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
G-3
N O
TE
S
ALL MEASURES STATED ON THIS SHEET, THE EROSION AND SEDIMENT CONTROL PLAN (SHEET EC-1) AND IN THE STORM WATER POLLUTION PREVENTION PLAN SHALL BE MAINTAINED IN FULLY FUNCTIONAL CONDITION UNTIL NO LONGER REQUIRED FOR A COMPLETED PHASE OF WORK OR FINAL STABILIZATION OF THE SITE. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE CHECKED BY A QUALIFIED PERSON IN ACCORDANCE WITH THE CONTRACT DOCUMENTS OR THE APPLICABLE PERMIT, WHICHEVER IS MORE STRINGENT, AND REPAIRED IN ACCORDANCE WITH THE FOLLOWING:
INLET PROTECTION DEVICES AND BARRIERS SHALL BE REPAIRED OR REPLACED IF THEY SHOW
SIGNS OF UNDERMINING, OR DETERIORATION.
ALL SEEDED AREAS SHALL BE CHECKED REGULARLY TO SEE THAT A GOOD STAND IS MAINTAINED.
AREAS SHOULD BE FERTILIZED, WATERED, AND RESEEDED AS NEEDED.
SILT FENCES SHALL BE REPAIRED TO THEIR ORIGINAL CONDITIONS IF DAMAGED. SEDIMENT SHALL
BE REMOVED FROM THE SILT FENCES WHEN IT REACHES ONE-HALF THE HEIGHT OF THE SILT
FENCE.
THE CONSTRUCTION ENTRANCES SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT
TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHTS-OF-WAY. THIS MAY REQUIRE PERIODIC TOP
DRESSING OF THE CONSTRUCTION ENTRANCES AS CONDITIONS DEMAND.
THE TEMPORARY PARKING AND STORAGE AREA SHALL BE KEPT IN GOOD CONDITION (SUITABLE
FOR PARKING AND STORAGE). THIS MAY REQUIRE PERIODIC TOP DRESSING OF THE TEMPORARY
PARKING AS CONDITIONS DEMAND.
CONTRACTOR SHALL ENSURE THAT OFF-SITE AREAS USED FOR BORROW OR SPOIL OF MATERIALS
USED FOR THIS PROJECT ARE PERMITTED IN ACCORDANCE WITH UPDES REQUIREMENTS AND
APPROPRIATE EROSION CONTROL MEASURE AND BMP'S BE PLACED TO ENSURE THAT EROSION
SEDIMENT IS CONTAINED.
1. THE STORM WATER MANAGEMENT PLAN IS COMPRISED OF EROSION CONTROL PLAN (EC-1), THE STANDARD DETAILS, THE PLAN NARRATIVE, PLUS THE PERMIT AND ALL SUBSEQUENT REPORTS AND
RELATED DOCUMENTS.
2. ALL CONTRACTORS AND SUBCONTRACTORS INVOLVED WITH STORM WATER MANAGEMENT SHALL
OBTAIN A COPY OF THE STORM WATER MANAGEMENT PLAN AND THE UTAH POLLUTANT DISCHARGE ELIMINATION SYSTEM GENERAL PERMIT (UPDES) AND BECOME FAMILIAR WITH THEIR CONTENTS.
3. CONTRACTOR SHALL IMPLEMENT BEST MANAGEMENT PRACTICES AS REQUIRED BY THE SWPPP.
ADDITIONAL BEST MANAGEMENT PRACTICES SHALL BE IMPLEMENTED AS DICTATED BY CONDITIONS
AT NO ADDITIONAL COST OF OWNER THROUGHOUT ALL PHASES OF CONSTRUCTION.
4. BEST MANAGEMENT PRACTICES (BMP'S) AND CONTROLS SHALL CONFORM TO FEDERAL, STATE, OR
LOCAL REQUIREMENTS OR MANUAL OF PRACTICE, AS APPLICABLE. CONTRACTOR SHALL
IMPLEMENT ADDITIONAL CONTROLS AS DIRECTED BY PERMITTING AGENCY OR OWNER.
5. SITE MAP MUST CLEARLY DELINEATE ALL STATE WATERS. PERMITS FOR ANY CONSTRUCTION ACTIVITY IMPACTING STATE WATERS OR REGULATED WETLANDS MUST BE MAINTAINED ON SITE AT
ALL TIMES.
6. CONTRACTOR SHALL MINIMIZE CLEARING TO THE MAXIMUM EXTENT PRACTICAL OR AS REQUIRED
BY THE GENERAL PERMIT.
7. GENERAL CONTRACTOR SHALL DENOTE ON PLAN THE TEMPORARY PARKING AND STORAGE AREA WHICH SHALL ALSO BE USED AS THE EQUIPMENT MAINTENANCE AND CLEANING AREA, EMPLOYEE PARKING AREA, AND AREA FOR LOCATING PORTABLE FACILITIES, OFFICE TRAILERS, AND TOILET
FACILITIES.
8. ALL WASH WATER (CONCRETE TRUCKS, VEHICLE CLEANING, EQUIPMENT CLEANING, ETC.) SHALL BE
DETAINED AND PROPERLY TREATED OR DISPOSED.
9. SUFFICIENT OIL AND GREASE ABSORBING MATERIALS AND FLOATATION BOOMS SHALL BE
MAINTAINED ON-SITE OR SHALL BE READILY AVAILABLE TO CONTAIN AND CLEAN UP FUEL OR
CHEMICAL SPILLS AND LEAKS.
10. DUST ON THE SITE SHALL BE CONTROLLED. THE USE OF MOTOR OILS AND OTHER
PETROLEUM-BASED OR TOXIC LIQUIDS FOR DUST SUPPRESSION OPERATIONS IS PROHIBITED.
11. RUBBISH, TRASH, GARBAGE, LITTER, OR OTHER SUCH MATERIALS SHALL BE DEPOSITED INTO SEALED CONTAINERS. MATERIALS SHALL BE PREVENTED FROM LEAVING THE PREMISES THROUGH THE ACTION OF WIND OR STORM WATER DISCHARGE INTO DRAINAGE DITCHES OR WATERS OF THE
STATE.
12. ALL STORM WATER MANAGEMENT MEASURES PRESENTED ON THIS PLAN, AND IN THE STORM
WATER MANAGEMENT PLAN, SHALL BE INITIATED AS SOON AS PRACTICABLE.
13. DISTURBED PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITY HAS STOPPED FOR AT LEAST 21 DAYS SHALL BE TEMPORARILY SEEDED. THESE AREAS SHALL BE SEEDED NO LATER THAN 14
DAYS FROM THE LAST CONSTRUCTION ACTIVITY OCCURRING IN THESE AREAS.
14. DISTURBED PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITY HAS PERMANENTLY STOPPED
SHALL BE PERMANENTLY SEEDED. THESE AREAS SHALL BE SEEDED NO LATER THAN 14 DAYS
AFTER THE LAST CONSTRUCTION ACTIVITY OCCURRING IN THESE AREAS. REFER TO THE GRADING
PLAN AND/OR LANDSCAPE PLAN.
15. IF THE ACTION OF VEHICLES TRAVELING OVER THE GRAVEL CONSTRUCTION ENTRANCES IS NOT
SUFFICIENT TO REMOVE THE MAJORITY OF DIRT OR MUD, THEN THE TIRES MUST BE WASHED
BEFORE THE VEHICLES ENTER A PUBLIC ROAD. IF WASHING IS USED, PROVISIONS MUST BE MADE TO INTERCEPT THE WASH WATER AND TRAP THE SEDIMENT BEFORE IT IS CARRIED OFF THE SITE.
16. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLES ONTO ROADWAYS OR
INTO STORM DRAINS MUST BE REMOVED IMMEDIATELY.
17. ON-SITE AND OFF-SITE SOIL STOCKPILE AND BORROW AREAS SHALL BE PROTECTED FROM
EROSION AND SEDIMENTATION THROUGH IMPLEMENTATION OF BEST MANAGEMENT PRACTICES.
STOCKPILE AND BORROW AREA LOCATIONS SHALL BE NOTED ON THE SITE MAP AND PERMITTED IN
ACCORDANCE WITH GENERAL PERMIT REQUIREMENTS. CONTRACTOR SHALL USE VEHICLE
TRACKING CONTROL AT ALL LOCATIONS WHERE VEHICLES WILL ENTER OR EXIT THE SITE.
CONTROL FACILITIES WILL BE MAINTAINED WHILE CONSTRUCTION IS IN PROGRESS, MOVED WHEN
NECESSARY, AND REMOVED WHEN THE SITE IS PAVED.
18. SLOPES SHALL BE LEFT IN A ROUGHENED CONDITION DURING THE GRADING PHASE TO REDUCE
RUNOFF VELOCITIES AND EROSION.
19. DUE TO THE GRADE CHANGES DURING THE DEVELOPMENT OF THE PROJECT, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR ADJUSTING THE EROSION CONTROL MEASURES (SILT FENCES,
DIVERSION SWALES, ETC.) TO PREVENT EROSION.
20. ALL CONSTRUCTION SHALL BE STABILIZED AT THE END OF EACH WORKING DAY. THIS INCLUDES
BACKFILLING OF TRENCHES FOR UTILITY CONSTRUCTION AND PLACEMENT OF GRAVEL OR
BITUMINOUS PAVING FOR ROAD CONSTRUCTION.
21. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DUE TO UNFORESEEN PROBLEMS
OR IF THE PLAN DOES NOT FUNCTION AS INTENDED.
22. INLET PROTECTION DEVICES SHALL BE INSTALLED IMMEDIATELY UPON INDIVIDUAL INLETS
BECOMING FUNCTIONAL.
23. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE DISPOSED OF WITHIN 30
DAYS AFTER FINAL STABILIZATION. FINAL STABILIZATION HAS OCCURRED WHEN ALL
SOIL-DISTURBING ACTIVITIES ARE COMPLETED AND A UNIFORM PERENNIAL VEGETATIVE COVER
WITH A DENSITY OF 70% HAS BEEN EMPLOYED.
24. BOX ELDER CREEK CROSSES THE SOUTHERN PORTION OF THE SITE, ENCOMPASSING A PFOA
WETLAND, AS DEFINED BY THE U.S. FISH & WILDLIFE SERVICE.
25. THE SOUTHERN PORTION OF THE SITE LIES WITHIN 100-YEAR FLOOD PLAIN ZONE A AS
DETERMINED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY. THIS AREA IS APPROXIMATED
ON SHEET EX-1; SEE THE NATIONAL FLOOD INSURANCE PROGRAM MAP NUMBER 49003C1838D
AVAILABLE AT MSC.FEMA.GOV FOR OFFICIAL DRAWINGS.
26. THERE WILL BE NO ASPHALT OR CONCRETE BATCH PLANTS ON SITE.
27. THERE ARE NO KNOWN HISTORIC PROPERTIES AT THIS LOCATION.
28. THE POTENTIAL FOR SOIL EROSION FOR THIS SITE IS SLIGHT TO MODERATE.
29. DAILY INSPECTIONS BY THE PROJECT SUPERINTENDENT, BI-WEEKLY INSPECTIONS BY THE
CONTRACTOR'S COMPLIANCE OFFICER, AND MONTHLY INSPECTIONS BY THE OWNER'S
CONSTRUCTION MANAGER MUST BE MADE TO DETERMINE THE EFFECTIVENESS OF THE SWPPP.
MAINTENANCE NOTES
STORM WATER POLLUTION PREVENTION PLAN
NOTE: GENERAL CONTRACTOR TO COMPLETE TABLE WITH THEIR SPECIFIC PROJECT SCHEDULE
SOIL EROSION/SEDIMENTATION CONTROL OPERATION TIME SCHEDULE
LANDSCAPING/SEED/FINAL STABILIZATION
PERMANENT CONTROL STRUCTURES
FOUNDATION / BUILDING CONSTRUCTION
TEMPORARY CONSTRUCTION ROADS
TEMPORARY CONTROL MEASURES
ROUGH GRADE / SEDIMENT CONTROL
FINISH GRADING
SITE CONSTRUCTION
STORM FACILITIES
STRIP & STOCKPILE TOPSOIL
CONSTRUCTION SEQUENCE SEP JUL AUGMAYAPR JUN DECOCT NOV JAN FEB MAR
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, SEP JUL AUGMAYAPR JUN
7/21/21
7/
/2
JS
B
JO
SH
U A
S.
B
LA
C
K
R
EA
D Y
TO
B
ID
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
G-4
LE
G
EN
D
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
3/4'' W
1'' W
2'' W
3'' W
4'' W
6'' W
8'' W
WATER
PROPOSEDEXISTING
W W
A ALGEBRAIC GRADE CHANGE
ABC AGGREGATE BASE COURSE
AC ASPHALTIC CEMENT
BC BUILDING CORNER
BEL BURIED ELECTRIC LINE
BF BOTTOM OF FOOTING
BLDG BUILDING
BM BENCHMARK
BP BEGIN POINT
BV BUTTERFLY VALVE
C&G CURB & GUTTER
CB CATCH BASIN
CL CENTERLINE
CLR CLEAR
CO CLEANOUT
CONC CONCRETE
Cu COPPER
C.Y. CUBIC YARD
DIA DIAMETER
DIP DUCTILE IRON PIPE
DWG DRAWING
E EAST OR EASTING
EA EACH
EL ELEVATION
EOC EDGE OF CONCRETE
EOP EDGE OF PAVEMENT
EP END POINT
ESMT EASEMENT
EX EXISTING
FF FINISHED FLOOR ELEVATION
FG FINISHED GRADE ELEVATION
FL FLOW LINE
FPS FEET PER SECOND
FT FOOT OR FEET
G GAS LINE
GB GRADE BREAK
HP HIGH POINT
HRZ HORIZONTAL
HWM HIGH WATER MARK
ID INSIDE DIAMETER
IN INCH(ES)
L LENGTH
LF LINEAR FEET
L/S LANDSCAPE
LP LOW POINT
MAX MAXIMUM
MFR MANUFACTURER
MGD MILLION GALLONS PER DAY
MH MANHOLE
MIN MINIMUM
N NORTH OR NORTHING
N/A NOT APPLICABLE
NE NORTHEAST
NTS NOT TO SCALE
NW NORTHWEST
OC ON CENTER
OD OUTSIDE DIAMETER
OHP OVERHEAD POWER
OWS OIL / WATER SEPARATOR
PC POINT OF CURVE
PI POINT OF INTERSECTION
PL PROPERTY LINE
PT POINT OF TANGENCY
PUE PUBLIC UTILITY EASEMENT
PVC POLYVINYL CHLORIDE
Q RATE OF FLOW
R RADIUS
R/W RIGHT OF WAY
REV REVISION
S SOUTH OR SLOPE
S/W SIDEWALK
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SE SOUTHEAST
SPEC SPECIFICATIONS
SSMH SANITARY SEWER MANHOLE
SS SANITARY SEWER
STD STANDARD
SW SOUTHWEST
TA TOP OF ASPHALT
TBC TOP BACK OF CURB
TC TOP OF CONCRETE
TG TOP OF GRATE
TOS TOP OF SLOPE
TS TOE OF SLOPE
TW TOP OF WALL
TYP TYPICAL
UTC UNTREATED BASE COURSE
VLV VALVE
VRT VERTICAL
W WEST
WTR WATER
UNKNOWN
EXISTING PROPOSED
ELECTRICAL MANHOLE
ABBREVIATIONS
STANDARD SYMBOLS
HATCH PATTERNS
SURFACE FEATURES
BUILDING / PAD
RIPRAP
CONSTRUCTION KEYNOTE TAGS
1-1/2'' W
GRAVEL
D00 OR DEMO PLAN
OR GRADING PLAN
OR SITE PLAN
OR WATER
OR SEWER
OR STORM DRAIN65
G1 G9
D99 50
FO
TV
TB
E
JB
PP
S
SD
W
E
T
FO
W
G
TV
T
CO
fo tv t jb pp s w e t fo w g tv tb co e sd
FIBER OPTIC MANHOLE
TELEPHONE MANHOLE
CABLE TV MANHOLE
ELECTRICAL POWER POLE
ELECTRICAL BOX
FIBER OPTIC BOX
JUNCTION BOX
TELEPHONE BOX
TELEPHONE PEDESTAL
CABLE TV BOX
LIGHT POLE
LIGHT POLE OPT 3
GAS METER
CLEANOUT
SEWER MANHOLE
WATER MANHOLE
WATER METER
FIRE HYDRANT
GATE VALVE
CROSS
TEE
90° BEND
45° BEND
22.5° BEND
11.25° BEND
STORM DRAIN MANHOLE
DROP INLET
CURB INLET
OIL/WATER
SAND/GREASE
FLARED END SMALL
SIGN
BOLLARD
10'' W
12'' W
3/4 INCH
1 INCH
1-1/2 INCH
2 INCH
3 INCH
4 INCH
6 INCH
8 INCH
10 INCH
12 INCH
4'' SD
6'' SD
10'' SD
12'' SD
15'' SD
16'' SD
18'' SD
STORM
PROPOSEDEXISTING
SD SDUNKNOWN
48'' SD
8'' SD
24'' SD
30'' SD
36'' SD
42'' SD
4 INCH
6 INCH
8 INCH
10 INCH
12 INCH
15 INCH
16 INCH
18 INCH
24 INCH
30 INCH
36 INCH
42 INCH
48 INCH
4'' SS
6'' SS
10'' SS
12'' SS
SEWER
PROPOSEDEXISTING
SS SSUNKNOWN
8'' SS
4 INCH
6 INCH
8 INCH
10 INCH
12 INCH
BEL
POWER
PROPOSEDEXISTING
OHPOVERHEAD
UNDERGROUND
BCTV
BFO
TEL
BTEL BTEL
COMMUNICATIONS
PROPOSEDEXISTING
CTVOVERHEAD CABLE TV
FO FO
UNDERGROUND CABLE TV
OVERHEAD FIBER OPTIC
UNDERGROUNG FIBER OPTIC
OVERHEAD TELEPHONE
UNDERGROUND TELEPHONE
2'' G
GAS
PROPOSEDEXISTING
G GUNKNOWN
2 INCH
HPGHIGH PRESSURE
LOD LOD
GB GB
X X X
CUT LINE
FILL LINE
LIMITS OF DISTURBANCE
DITCH
GRADE BREAK
FENCE - BARBED
FENCE - CHAIN LINK
FENCE - DECORATIVE
FENCE - WOOD
WALL - BLOCK
WALL - PANEL
WALL - ROCK
R/W RIGHT OF WAY
WALL - CONCRETE
CENTERLINE (ROAD/ENTITY)
CURB & GUTTER
PARCEL LINE
PROPERTY BOUNDARY
JUT
TOP TOP
MISCELLANEOUS
PROPOSEDEXISTING
DEMO
TOE
UNKNOWN PIPE
JOINT UTILITY TRENCH
TOE OF SLOPE
TOP OF SLOPE
DIRECTIONAL FLOWLINE
GUARDRAIL
RAILROAD TRACKS
EDGE OF PAVEMENT
top top toe
EXISTING/PROPOSED
CONTOUR - MAJOR
CONTOUR - MINOR
10' PUBLIC UTILITY & DRAINAGE
EASEMENT (P.U.E.)
CONCRETE SIDEWALK /
FLATWORK
HEAVY DUTY
PAVEMENT SECTION
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, 7/21/21
7/
/2
JS
B
JO
SH
U A
S.
B
LA
C
K
R
EA
D Y
TO
B
ID
S
ET
61 OR ELECTRITY64
RE-GRADED ONSITE
BORROW OR BASE
MATERIAL
GARAGE
SALT
STORAGE
BU
IL
D
IN
G
EVAPORATIVE POND
4564 45
4570 45
4564 4566
EAST POWERPLANT ROAD
PARCEL: 03-043-0016
PARCEL: 03-043-0016
PARCEL: 03-043-0015
PARCEL: 03-043-0001
PARCEL: 03-233-0006
PARCEL: 03-043-0031
s pp pp pp e e
200 SOUTH STREET - SR-90
s fo
BOX ELDER CREEK
s s co
ASPHALT
WOOD FENCE
CHAIN LINK FENCE
CHAIN LINK FENCE
CHAIN LINK FENCE
GATE
GATE
GATE
SALT SPREADER RACK
FFE=4564.44
RETAINING WALL
RETAINING WALL
WOOD FENCE
WOOD FENCE
FLAG POLE
LIGHT
CONCRETE
LIGHT
GAS PUMP
BOLLARD (TYP)
ELECTRIC JUNCTION
BOX 2'x2.5'
BOLLARD
HOSE BIB
POWER POLE
POWER POLE
POWER POLE
BOLLARD (TYP)
DOOR
DOOR
DOOR
AIR CONDITIONER
SEWER MANHOLE
RIM=4567.61
4" PVC FL(NW)=4565.56
ELECTRIC METER
WASH RACK
BUILDING
TUFF SHED
TANK
TANK
SPRINKLER VALVE
SEWER PUMP
RIM=4567.70
4" PVC FL(NE)=UNKNOWN
STORM DAYLIGHT
12" HDUP FL(NW)=4564.51
STORM DAYLIGHT
12" HDUP FL(SE)=4563.40
BUILDING
10'x3' TANK
10'x3' TANK
BOLLARD (TYP)
SEWER MANHOLE
RIM=4585.53
12" RCP FL(NW)=4578.83
12" RCP FL(SE)=4578.93
2" POWER CONDUIT
FIBER OPTIC CABLE 2x2.5
CHAIN LINK FENCE
CONCENTRATOR
WATER VALVE
HOSE BIB
OVERLAND FLOW
CHANNEL
SHOP WATER
DISCHARGE TO POND
4" PVC FL(SE)=4563.73
SEWER MANHOLE
SEWER CLEANOUT
12" RCP SEWER MAIN
12" RCP SEWER MAIN
N61° 28' 56"W 449.36'
N O
R T
H
.0
0'
EAST 570.00'
S
' 3 0"
W
.0
0'
N0° 00' 00"E 2.39' toe toe toe to e to e to e to p to p to p to p to p to p to p to p to p toptop
FEMA 100-YEAR FLOODPLAIN
BOUNDARY
FEMA 100-YEAR FLOODPLAIN
BOUNDARY
FEMA 100-YEAR FLOODPLAIN
BOUNDARY
FEMA 100-YEAR FLOODPLAIN
BOUNDARY
SEWER FORCE MAIN
SIZE UNKNOWN
(APPROX. LOCATION)
JERSEY BARRIERS
WATER PIPE
(APPROX. LOCATION)
FOUND BOX ELDER COUNTY MONUMENT
FOR THE NORTHWEST CORNER
OF THE NORTHWEST QUARTER
OF THE SOUTHEAST QUARTER
SECTION 19, T9N, R1W, SLB&M
N90° 00' 00"E 2703.01'
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
EX-1
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
H
O R R O C K
S
E
N G I N E E R
S
LOCATED IN THE SOUTHEAST QUARTER OF SECTION 19,
TOWNSHIP 9 NORTH, RANGE 1 WEST,
SALT LAKE BASE AND MERIDIAN
0 80'40'
SCALE: 1" = 80'
N
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS
IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT
LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE
CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE
RELATED TO THE ISSUE.
NOTES
1. THE PURPOSE OF THE SURVEY CONDUCTED IS TO SHOW THE
EXISTING CONDITIONS FOR FUTURE IMPROVEMENTS.
2. EXISTING RIGHT OF WAYS SHOWN ARE ESTIMATIONS AND ARE
FOR REFERENCE ONLY.
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, HATCH LEGEND
APPROX. AREA OF FEMA ZONE A
(100-YEAR FLOODPLAIN)
7/21/21
7/
/2
JS
B
JO
SH
U A
S.
B
LA
C
K
R
EA
D Y
TO
B
ID
4564 45
4570 45
4564 4566 s pp pp pp e e s fo s s co toe toe toe to e to e to e to e to e to p to p to p to p to p to p to p to p to p to p to p to ptoptop
CU
T
CU
T
CU
T
CU
T
CU
T
CUT
CU
T
CU
T
CU
T
CU
T
CU
T
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
DM-1
D
EM
O
LI
TI
O
N P
LA
N
H
O R R O C K
S
E
N G I N E E R
S
0 60'30'
SCALE: 1" = 60'
N
DEMOLITION KEYNOTES:
REMOVE AND DISCARD EXISTING STAIRS, WASH STATION,
AND FOOTINGS
REMOVE ASPHALT PAVING
UDOT TO DRAIN POND WATER PRIOR TO CONSTRUCTION.
CONTRACTOR TO DISPOSE OF REMAINING POND SILT,
SLUDGE, OR OTHER DEBRIS
REMOVE AND DISCARD EXISTING VALVE AND HOSE BIB
REMOVE AND DISCARD EXISTING 4IN SEWER PIPE.
REMOVE AND DISCARD EXISTING WATER LINE.
CONTRACTOR TO FIELD VERIFY EXISTING PIPE LOCATION
AND EXTENTS OF DEMOLITION
REMOVE AND DISCARD SANDER RACK STRUCTURE AND
FOUNDATIONS
EXISTING BRINE CONCENTRATOR TO BE REMOVED BY
UDOT PRIOR TO CONSTRUCTION
D01
D02
D03
D04
D05
D06
D07
D08
PROTECTION KEYNOTES:
PROTECT IN PLACE EXISTING POWER POLE TO REMAIN
PROTECT IN PLACE EXISTING UTILITY METER/STRUCTURE
TO REMAIN
PROTECT IN PLACE EXISTING SITE FEATURE/STRUCTURE
TO REMAIN
PROTECT IN PLACE EXISTING UTILITY PIPE TO REMAIN
PROTECT EXISTING CONCRETE SURFACE
PROTECT IN PLACE EXISTING FENCE TO REMAIN
PROTECT IN PLACE EXISTING JERSEY BARRIERS /
RETAINING WALLS TO REMAIN
P01
P02
P03
P04
P05
P06
P07
RELOCATION KEYNOTES:
EXISTING BRINE TANKS AND BRINE PUMP SHED TO BE
RELOCATED BY UDOT PRIOR TO CONSTRUCTION
R01
P01
D01
R01
P02
P05
P05
P05
TYP
P04 P03
P03
D07
P01
D03
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS
IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT
LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE
CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE
RELATED TO THE ISSUE.
NOTES
1. CONTRACTOR SHALL COORDINATE SCHEDULE AND EXTENTS OF DEMOLITION WITH THE UDOT SITE
SUPERINTENDENT AND ADJACENT PROPERTY OWNERS. CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY
TO PREVENT DISRUPTION OF ADJACENT BUSINESSES.
2. CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD AND BRIGHAM CITY OFFICIALS 48 HOURS PRIOR TO THE
START OF ANY DEMOLITION.
3. CONTRACTOR SHALL INSPECT THE EXISTING STRUCTURES PRIOR TO THE START OF ANY DEMOLITION FOR ANY
CONDITIONS WHICH MAY AFFECT THE DEMOLITION PROCEDURES.
4. ANY CONDITIONS WHICH MAY BE UNCOVERED OR DISCOVERED DURING THE PROCESS OF DEMOLITION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND ENGINEER OF RECORD IMMEDIATELY. ADDITIONAL EXPENSES INCURRED BY UNFORESEEN CONDITIONS SHALL BE APPROVED BY THE OWNER PRIOR TO THE ADDITIONAL WORK.
5. CONTRACTOR SHALL HAVE WATER ON SITE FOR DUST ABATEMENT AT ALL TIMES DURING THE DEMOLITION
ACTIVITIES.
6. ALL UTILITY SERVICE LINES PROVIDING SERVICE TO ADJACENT PROPERTY OWNERS MUST BE MAINTAINED.
7. ALL TRASH PITS, LOOSE DEBRIS, JUNK, RUBBLE, & GARBAGE TO BE REMOVED AND PROPERLY DISPOSED FROM
ENTIRE SITE. CONTRACTOR TO PLACE PROPERLY COMPACTED FILL IN ALL REMOVED TRASH PITS. CONTRACTOR
TO FILL COMPLETELY ALL HOLES, EXISTING OR CREATED FROM DEMOLITION.
8. FILL UNDER EXISTING/PROPOSED ASPHALT SHALL MATCH DETAIL 1 ON SHEET DT-6 AND BE GRADED TO DESIGN ELEVATION AND SLOPE. FILL IN ALL OTHER AREAS TO BE OF SIMILAR TYPE AND QUALITY OF EXISTING MATERIAL.
D04
P04
P03
SALT STORAGE
GARAGE
FUEL
SANDER RACK
STO
R
AG
E
BOX ELDER CREEK
P02
D02
D05
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, D08
P03
HATCH LEGEND
ASPHALT DEMOLITION AREA.
SEE SHEET CS-1 FOR
HORIZONTAL CONTROL
P03
P03
P03
P02
P06
P02
P06
P06
P06
P06
P06
D02
EAST
POWERPLANT
ROAD
P04
P02
P04
7/21/21
7/
/2
JS
B
D06
P03
JO
SH
U A
S.
B
LA
C
K
R
EA
D Y
TO
B
ID
S
ET
P07
P02
P05
P05
P03
P01
P07
P07
10'' SD
10'' SD
10'' SD
pp pp e jb s co to e
CP #1
CP #4
6'' S
S
6'' S
S
6'' S
S
6'' S
S
6'' S
S
W
W
W
W
W
W
W
15'' SD
15'' SD
'' S
D
'' S
D 6'' S
D
6'' S D
6'' SD
SD
S
FI
LL
FI
LL
FI
LL
FILL FILL FILL FILL FILL FILL FILL
FILL
TO
P
TO
P
TOP
TOP
TOP
TOP
TOP
TOP
TO
P
TO
P
TO
P
TOP
TOP
TOP
TOP
TO
P
G B
G B
G B
G B
G B
TOE
TOE
TOE
TOE
TO
E
TOE
TOE
TOE
TO
E
TO
E
TO
P
TOP
TOP
H W
M
HWM
HWM
HWM
HW
M
HWM
HWM
H W
M
6'' SS
CO
FILL
FILL
FILL
FILL
GB
GB
GB
C U
T C
U T
C U
T C
U T
C U
T
SEE ENLARGED PLAN
SHEET CG-2
SEE INSET PLAN
THIS SHEET
WW
W
'' S
D
'' S D
'' S
D
'' S D
BE
L
BEL
22.32'
.6
7.25'
SEE NOTE 3
1.
5'
9.
SE
E N
O
TE
H
O R R O C K
S
E
N G I N E E R
S
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
0 40'20'
SCALE: 1" = 40'
N
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS
IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT
LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE
CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE
RELATED TO THE ISSUE.
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
CS-1
SI
TE
H
O R
IZ
O
N
TA
L
PL
AN
SALT STORAGE
GARAGE
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, CONSTRUCTION KEYNOTES:
BRINE TANKS AND BRINE PUMP SHED TO BE REINSTALLED
BY UDOT ON NEW CONCRETE SLAB
FURNISH AND INSTALL MATERIAL STORAGE BIN (SEE
STRUCTURAL)
FURNISH AND INSTALL ASPHALT PAVEMENT SECTION (SEE
DETAIL 1 SHEET DT-6)
FURNISH AND INSTALL 7-FT OF CONCRETE RIBBON CURB
(SEE DETAIL 4 SHEET DT-6)
FURNISH AND INSTALL CONCRETE TANK SLAB WITH 6-INCH
CONTAINMENT CURB (SEE DETAIL 2 SHEET DT-6)
FURNISH AND INSTALL CONCRETE PUMP HOUSE SLAB
(SEE DETAIL 3 SHEET DT-6)
FURNISH AND INSTALL REINFORCED CONCRETE BRINE
VAULT AND MAT FOUNDATION (SEE STRUCTURAL)
FURNISH AND INSTALL EXPANSION JOINT AND 12-INCH
FILLER BOARD BETWEEN STRUCTURAL PAD AND
ADJACENT CURB
FURNISH AND INSTALL 70-FT OF 30-INCH CURB AND
GUTTER (SEE DETAIL 5 SHEET DT-6)
INSTALL PVC PIPE SLEEVE AND KNIFE GATE VALVE (SEE
KEYNOTE 75 SHEET CG-1).
FURNISH AND INSTALL APPROX. 66 FEET OF 4-FT
CONCRETE WATERWAY (SEE DETAIL 6 SHEET DT-6)
FURNISH AND INSTALL APPROX 105 FEET OF 4-FT-WIDE
RIPRAP CHANNEL (SEE KEYNOTE 72 ON SHEET CG-1)
INSTALL NEW UNPAVED SHOULDER, INFILL, YARD
STORAGE, OR STORM WATER DETENTION SURFACE WITH
ACCEPTABLE ON-SITE BORROW MATERIAL. SEE NOTE 2
REGARDING "CUT" AND "FILL" AREAS
FURNISH AND INSTALL NEW 11-BAY SANDER RACK AND
FOUNDATIONS (SEE STRUCTURAL)
2-BAY SANDER RACK ADDITION (SEE BID ADD ALTERNATE
#1)
FUTURE MAG STORAGE TANK (NOT IN CONTRACT)
BOX ELDER CREEK
NOTES:
1. HORIZONTAL CONTROL POINT TABLES ARE GIVEN ON SHEET CS-2.
2. IN "FILL" AREAS, PLACE REUSED ON-SITE BORROW MATERIAL IN LIFTS
NO GREATER THAN 8 INCHES AND COMPACT TO 95% MODIFIED
PROCTOR. IN "CUT" AREAS, SCARIFY THE TOP 6 INCHES AND
RECOMPACT TO 95% MODIFIED PROCTOR.
3. FIELD-VERIFY PUMP SHED DIMENSIONS TO ENSURE SHED WILL BE
FULLY SUPPORTED ON CONCRETE SLAB. CONTACT ENGINEER
IMMEDIATELY IF FULL SUPPORT CANNOT BE ACHIEVED WITH
DIMENSIONS SHOWN.
7/
/2
JS
B R
EA
D
Y
TO
B
ID
S
ET
0 7.5' 15'
SCALE: 1" = 15'
BRINE MAKING ENLARGED PLAN
JO
SH
U A
S.
B
LA
C
K
7/21/21
POINT TABLE
POINT #
NORTHING
3707032.36
3706996.98
3707210.58
3707051.22
3707089.69
3706984.00
3707014.21
3707022.31
3707145.38
3707118.46
3707168.73
3707324.81
3707324.78
3707104.96
3707303.61
3707032.37
3707132.11
3707260.60
3707149.01
3707324.45
3707324.45
3707297.08
3707303.61
3707006.19
3706983.10
3707107.52
3707148.65
3707033.57
3707148.28
3707294.34
EASTING
1504777.64
1504935.53
1504947.86
1504603.95
1504672.81
1504697.54
1504698.17
1504698.33
1504786.71
1504541.15
1504565.95
1504561.94
1504582.04
1504563.54
1504845.09
1504642.62
1504800.81
1504781.49
1504592.83
1504822.59
1504845.09
1504845.57
1504822.59
1504686.62
1504614.50
1504649.37
1504777.36
1504641.01
1504794.61
1504850.09
DESCRIPTION
CP#1 MAG
CP#2 MAG
CP#3 MAG
CP#4 MAG
TBC/EOC
EOP
EOP
EOP
SSMH
FG
EOP/FL
FG
EOP
FL/TOP
EOP/BVW
TOE
EOP
SDI
EOP/BC/GB
EOP/BVW
BVW
FL
EOP/BVW
FL
TOP
EOP/BC/FL
OWS
FL
EOP
EOP
POINT TABLE
POINT #
NORTHING
3707303.70
3707151.38
3707300.73
3707080.03
3707142.11
3707136.61
3707324.60
3707302.91
3707303.22
3707318.22
3707317.91
3707319.96
3707304.96
3707183.97
3707107.00
3707036.01
3707016.68
3706978.78
3707038.51
3707048.51
3707067.70
3707089.48
3707057.50
3707024.47
3707005.86
3707024.00
3707043.59
3707048.35
3707060.58
3706964.17
EASTING
1504712.26
1504589.60
1504716.86
1504664.00
1504804.30
1504786.33
1504712.47
1504792.26
1504760.26
1504760.41
1504792.41
1504584.42
1504584.27
1504639.92
1504692.54
1504637.80
1504685.69
1504655.23
1504556.40
1504556.14
1504552.64
1504566.11
1504650.10
1504643.89
1504669.26
1504563.96
1504559.42
1504526.24
1504507.66
1504659.98
DESCRIPTION
GB
FL
FL
HYD
EOP
EOP
EOP/GB
BC
BC
BC
BC
BC
BC
SDI
SDMH
FL/TOE
TOP
TOE
TOP
TOP
TOP
FL/TOE
FL
TOE
FL/TOE
SDI
FL
FL
FL
TOP
POINT TABLE
POINT #
NORTHING
3707042.94
3707105.54
3707021.54
3707014.57
3707007.86
3707116.93
3707054.55
3707220.35
3707057.79
EASTING
1504534.46
1504554.65
1504567.88
1504557.03
1504681.37
1504564.33
1504661.53
1504551.17
1504649.70
DESCRIPTION
FL
TOP
TOE
TOP
FL/TOP
FL
CO
FG
TBC
toe toe toe toe to e to e to e to e jb
CP #2
CP #3
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
CS-2
SI
TE
H
O R
IZ
O
N
TA
L
PL
AN
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS
IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT
LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE
CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE
RELATED TO THE ISSUE.
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, 7/
/2
JS
B
JO
SH
U A
S.
B
LA
C
K
7/21/21
H
O R R O C K
S
E
N G I N E E R
S
0 40'20'
SCALE: 1" = 40'
N
GARAGE
FUEL PUMPS
R
EA
D Y
TO
B
ID
S
ET
NOTE:
CONTROL POINTS HAVE BEEN SET WITH MAG-TYPE SURVEY NAILS
DRIVEN INTO THE EXISTING PAVEMENT. THERE MAY ALSO BE PAINT
AROUND THE NAILS TO ASSIST IN LOCATING. THE CONTRACTOR IS
ADVISED NOT TO COMMENCE WITH SITE DEMOLITION ACTIVITIES
UNTIL ALL CONTROL POINTS HAVE BEEN LOCATED AND TIED INTO
THE CONSTRUCTION SURVEYOR'S STAKING CONTROL.
10'' SD
toe toe toe to e to e to e to e to e to p to p to p to p to p to p to p to p to p to p to p to ptoptop pp pp pp e jb s s to e
6'' S
S
6'' S
S
6'' S
S
W
W
W
W
15'' SD
'' S
D
6'' S D
6'' SD
SD
S
FI
LL
FI
LL
FILL FILL FILL FILL FILL
TO
P
TOP
TOP
TOP
TOP
TO
P
TO
P
TOP
TOP
TOP
G B
G B
G B
TOE
TOE
TO
E
TOE
TOE
TO
E
TOP
TOP
HWM
HWM
HW
MHWM
H W
M 6'' SS
CO
FILL
FILL
FILL
GB
GB
C U
T C
U T
C U
T
8 LF 6" PVC @ 6.34%
3 LF 6" PVC @ 1.01%
195 LF 6" PVC @ ±1.00%
EXISTING MANHOLE
RIM: 85.53
FL IN: 78.93 12" (SE)
FL OUT: 78.83 12" (NW)
17 LF 6" PVC @ 10.26%
93 LF 2" CTS
±102 LF 2" CTS
63 LF 6" PVC @ ±1.00%
25 LF 2" CTS
23 LF 2" CTS
10 LF 2" CTS
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
SEWER KEYNOTES:
TRUCK WASH WATER DIVERSION BOX (SEE SHEET CG-2)
FL OUT: 64.38
SUMP: 62.38
EXISTING OIL/WATER SEPARATOR
RIM: 67.61
FL OUT: �
FURNISH AND INSTALL 1200/1500 GAL OIL/WATER
SEPARATOR (SEE DETAIL 1 SHEET DT-5)
RIM: 66.86
FL IN: 63.51 6" (W)
FL OUT: 63.41 6" (E)
FURNISH AND INSTALL 48" MANHOLE (SEE DETAIL 1 SHEET
DT-4)
RIM: 66.86
FL IN: 63.31 6" (W)
FL IN: 63.37 6" (E)
FL OUT: 63.21 6" (SW)
FURNISH AND INSTALL SEWER CLEANOUT (SEE DETAIL 2
SHEET DT-5)
RIM: 64.21
FL OUT: 62.44
EXISTING SEWER PUMP
RIM: 67.70
FL IN: ±61.23 6" (NE) (SEE NOTE 5)
FL IN: UNK ELEV, UNK SIZE (NE)
FL OUT: UNK ELEV, UNK SIZE (S)
CONNECT PIPE TO EXISTING STRUCTURE AT SAME
ELEVATION AS EXISTING PIPE INVERT. CONTRACTOR TO
FIELD VERIFY
ASSUMED EXISTING PRESSURIZED SEWER LATERAL -
LOCATION, SIZE, AND ELEVATION UNKNOWN.
CONTRACTOR TO FIELD VERIFY
ASSUMED EXISTING GRAVITY SEWER LATERAL - LOCATION,
SIZE, AND ELEVATION UNKNOWN. CONTRACTOR TO FIELD
VERIFY
WYE CONNECTION
FL IN: ±61.80
WATER KEYNOTES:
CONNECT TO EXISTING WATER LINE. FIELD-VERIFY
EXISTING VALVE AND LINE CONNECTIONS TO DETERMINE
OPTIMAL TIE-IN FITTINGS AND LOCATION. PROVIDE
DISSIMILAR MATERIAL COUPLERS WHERE APPLICABLE
FURNISH AND INSTALL CURB STOP VALVE (SEE DETAILS 1
AND 3 SHEET DT-7)
FURNISH AND INSTALL ABOVE-GRADE WASH RACK PIPING
AND RISERS (SEE DETAILS 1 AND 2 SHEET DT-7)
FURNISH AND INSTALL FREEZELESS YARD HYDRANT (SEE
DETAIL 3 SHEET DT-7)
LOOP WATER LINE AROUND PROPOSED STORM DRAIN
LINE. MAINTAIN 18" CLEAR VERTICAL SEPARATION AND 4'
OF COVER
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS
IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT
LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE
CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE
RELATED TO THE ISSUE.
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
CU-1
U
TI
LI
TY
P
LA
N
H
O R R O C K
S
E
N G I N E E R
S
0 60'30'
SCALE: 1" = 60'N
SALT STORAGE
GARAGE
FUEL
STO
R
AG
E
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, BOX ELDER CREEK
EAST POWERPLANT
ROAD
7/21/21
7/
/2
JS
B40
ELECTRIC KEYNOTES:
FURNISH AND INSTALL CONDUIT AND FEEDER LINE
BETWEEN EXISTING ELECTRICAL PANEL AND RELOCATED
PUMP SHED. CONTRACTOR TO COORDINATE AND VERIFY
PUMP SHED ELECTRICAL SERVICE REQUIREMENTS WITH
UDOT SITE SUPERINTENDENT TO PROVIDE ALL
NECESSARY CONNECTIONS, COMPONENTS, JUNCTION
BOXES, ETC. TO ENERGIZE EXISTING POWER
RECEPTACLES. ALL FEEDER LINE SHALL BE ENCASED IN
CONDUIT AND ALL WORK SHALL MEET THE
REQUIREMENTS OF NFPA 70, NEC.
JO
SH
U A
S.
B
LA
C
K
NOTES:
1. TRUNCATED ELEVATIONS ARE OVER A BASE
ELEVATION OF 4500 FEET.
2. ALL WATER PIPE TO BE 2-INCH C-901 CTS TUBING.
3. ALL SEWER PIPE SHALL BE 6-INCH SDR-35.
4. SEE DETAILS 1 AND 2 SHEET DT-1 FOR PIPE
BEDDING AND TRENCHING REQUIREMENTS.
5. CONTRACTOR TO FIELD ADJUST ALL TIE INS TO
EXISTING FACILITIES AS NECESSARY TO AVOID
CONFLICTS AND ENSURE THE SYSTEMS
FUNCTION AS DESIGNED.
R
EA
D Y
TO
B
ID
S
10'' SD
10'' SD
pp pp e s co to e
6'' S
S
6'' S
S
6'' S
S
6'' S
S
6'' S
S
W
W
W
W
W
W
W
15'' SD
15'' SD
'' S
D
'' S
D 6'' S
D
6'' S D
6'' SD
SD
S
FI
LL
FI
LL
FI
LL
FILL FILL FILL FILL FILL FILL FILL
FILL
TO
P
TO
P
TOP
TOP
TOP
TOP
TOP
TOP
TO
P
TO
P
TO
P
TOP
TOP
TOP
TOP
TO
P
G B
G B
G B
G B
G B
TOE
TOE
TOE
TOE
TO
E
TOE
TOE
TOE
TO
E
TO
E
TO
P
TOP
TOP
H W
M
HWM
HWM
HWM
HW
M
HWM
HWM
H W
M
6'' SS
CO
FILL
FILL
FILL
FILL
GB
GB
GB
C U
T C
U T
C U
T C
U T
C U
T
TA: 64.24
FL: 63.92
TA: 64.51
TA: 66.10
TA: 66.89
FG: 66.65
TA: 67.02
FG: 64.96FG: 65.69
FG: 65.55
FG: 65.79
FG: 65.78
2.
8%
2.6%
2.5% 1.9%
3.3%
4:
2.4%
2.5%
2.7%
2.1%
0.9%
1.9%
2.5
11.8%
5:1
2.4%
FG: 67.09
TA: 64.56
FG: 65.73
FG: 64.26
FG: 61.30
FG: 63.66
FL: 63.38
FG: 63.58
3.
4%
1.3%
2.4%
FL: 62.66
0.0%
1.
8%
TA: 65.46
FG: 64.36
TC: 64.46
TC: 64.46
FG: 64.26
SEE ENGLARGED PLAN
SHEET CG-2
3.1%
FL: 61.03
FL: 58.41
TA: 67.53
PIPE DAYLIGHT
FL: 60.16 15" (NE)
93 LF 15" HDPE @
0.31%
90 LF 15" HDPE @ 0.21%
82 LF 6" P
VC @ 2.61%
TA: 65.15
5.
0%
FG: 65.23
TA: 65.77
TA: 66.87
TA: 65.64
TA: 67.32
FL: 64.51
FG: 60.16
2.2
5:1
FG: 63.66
FG: 63.60
FG: 61.36
FG: 63.66
3:1
0.0%
4.9%
FG: 63.60
45 LF 6" PVC @ 0.56%
FL: 60.16
161 LF 10" HDPE @ 0.50%
FG: 65.35
2.0%
2.6%
2.6%
TA/TC: 65.46TA: 66.72
TA: 66.17
TA: 65.82
1.
4%
TA: 65.74
TA: 64.45
3:1
3:
11.8%
FG: 63.90
FG: 60.16
FG: 64.21
FL: 60.16
TA: 66.93
TA: 67.44
FG: 66.86
2.
0%
1.5%
2.4%
1.
9%
1.
8%
4:1
4:
TA: 65.43
3.8%
FG: 65.76
FG: 65.15
TA: 65.95 FG: 65.67
0.5
FL: 60.16
FL: 64.23
FL: 63.860.
5%
FL: 63.20
3:1
3:
3:
3:1
FG: 63.27
FG: 63.60
FG: 63.66
FG: 63.60
FG: 61.66
FG: 63.66
7.5%
13.6%
45614562
FG: 64.92
FG: 63.60
FL: 63.67
4.6
.6
TA: 66.05
FG: 64.31
FG: 64.63
FG: 65.74
FG: 65.62
FG: 65.68
4:1
4:1
2.7%
1.6%
1.
4%
1.3%
1.
1%
SEE INSET PLAN
THIS SHEET
.5%
TA: 65.55
1.6%
WW
W
'' S
D
'' S D
'' S
D
'' S D
BE
L
BEL
2.2% 1.0%
0.
9%
2.
0%
0.
9%
1.1%
1.1% 1.0%
1.1%
1.0%
1.0%
2.
0%
1.0% 4565
0.5%
2.
7%
1.3
2.3%
FG: 64.35
TA/FL: 64.42 TC/TBC:64.77
FL: 63.91
TBC:64.68
TBC:64.75
TC: 64.64
TBC:64.45
TBC:64.41
TC/TBC:64.51
TC: 64.18
FG: 64.75
TC: 63.95
TC: 64.25 TC: 64.14
FG: 64.09
FL: 63.94
TC/TBC:64.60
TC: 64.78
TA/TC: 64.42
FL: 64.27
FG: 64.66
TA/TC: 64.09
TA/TC: 64.47
TC/TBC:64.66
TC: 64.55
FL: 63.92
TC/TBC:64.89
TBC:64.92
TBC:64.64
0.2%
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
GRADING KEYNOTES:
GRADING LOW POINT
GRADING HIGH POINT
GRADE BREAK
DRAINAGE PATH/SWALE
MATCH EXISTING ELEVATION
TRANSITION FROM FLAT GUTTER TO STANDARD SECTION
(SEE DETAIL 5 SHEET DT-6)
G1
G2
G3
G4
G5
G6
STORM DRAIN KEYNOTES:
FURNISH AND INSTALL 2' X 2' STORM ELEVATED INLET AND
CATCH BASIN WITH GALVANIZED STEEL ORIFICE PLATE
(SEE DETAILS 1 & 2 SHEET DT-2)
GRATE: 61.90
FL OUT: 60.70 6" (NW) - 2&5
8" DIA. ORIFICE, MATCH PIPE FL
SUMP: 59.40
FURNISH AND INSTALL 4' X 4' STORM DROP INLET AND
CATCH BASIN (SEE DETAIL 1 SHEET DT-2)
GRATE: 64.36
FL OUT: 61.58 10" (SW)
FURNISH AND INSTALL 4' X 4' STORM DROP INLET AND
CATCH BASIN (SEE DETAIL 1 SHEET DT-2)
GRATE: 63.58
FL IN: 60.77 10" (NE)
FL OUT: 60.67 15" (SE)
FURNISH AND INSTALL 48" JUNCTION MANHOLE (SEE
DETAIL 1 SHEET DT-3)
RIM: 64.92
FL IN: 61.57 6" (NE)
FL IN: 60.39 15" (NW)
FL OUT: 60.34 15" (SW)
FURNISH AND INSTALL 6" SCH-40 PVC PIPE (SEE DETAILS 1
AND 2 SHEET DT-1)
FURNISH AND INSTALL 10" CORRUGATED HDPE PIPE (SEE
DETAILS 1 AND 2 SHEET DT-1)
NOT USED
FURNISH AND INSTALL 15" CORRUGATED HDPE PIPE (SEE
DETAILS 1 AND 2 SHEET DT-1)
FURNISH AND INSTALL 4' WIDE V-SHAPED LOOSE RIPRAP
CHANNEL WITH APPROX. 1:6 CROSS SLOPE AND D50 6"
STONES. FOLLOW UDOT STANDARDS SECTION 02373
FURNISH AND INSTALL 4' WIDE V-SHAPED LOOSE RIPRAP
CHANNEL WITH APPROX. 1:6 CROSS SLOPE AND D50 6"
STONES TO CENTERLINE OF EXISTING DRAINAGE DITCH AS
SHOWN. INSTALL SUCH THAT FINISHED EDGES ARE
APPROX. FLUSH WITH EXISTING GROUND. FOLLOW UDOT
STANDARDS SECTION 02373
FURNISH AND INSTALL 15" BELL-SHAPED PIPE DISCHARGE
WITH ZINC COATED ANIMAL GUARD GATE
FURNISH AND INSTALL 6-INCH HDPE MITERED DRAIN
GRATE AT STORM DRAIN DISCHARGE
FL OUT: 60.45
FURNISH AND INSTALL 3" PVC GATE VALVE WITH KNIFE
GATE SUCH AS "VALTERRA 3" SLIP X SLIP" OR APPROVED
EQUAL. FLOW LINE TO MATCH TOP OF SLAB
FURNISH AND INSTALL 3" SCH-40 PVC PIPE. DAYLIGHT
THROUGH CURB AT GUTTER FLOWLINE
STORM WATER DIVERSION BOX
FL OUT: 64.38
SUMP: 62.38
646464
656565
666666
676767
686868
696969
707070
717171
727272
747474
757575
767676
777777
787878
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF
EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL
UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT
FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS
SHOWN ON THE PLANS. IF A CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE RELATED TO THE ISSUE.
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
CG-1
G R
AD
IN
G
D R
AI
N
AG
E
PL
AN
DETENTION POND SIZING
HIGH-WATER/SPILL ELEVATION 4562.66
DRAIN ELEVATION 4561.40
MINIMUM ELEVATION 4560.16
POND VOLUME @ SPILL ELEVATION (CF) 16,445
POND VOLUME @ DRAIN ELEVATION (CF) 7,188
100-YEAR STORM VOLUME (CF) 17,526
90TH PERCENTILE STORM VOLUME (CF) 7,155
ORIFICE DISCHARGE (CFS) 0.31
H
O R R O C K
S
E
N G I N E E R
S
0 40'20'
SCALE: 1" = 40'N
SALT
STORAGE
GARAGE
G3
NOTE
1. TRUNCATED SPOT ELEVATIONS SHOWN
REFERENCE A BASE ELEVATION OF 4500 FEET.
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Au gu st
, 2
BOX ELDER CREEK
G5
G1
7/21/21
7/
/2
JS
B
G2
72 71
G5
0 7.5' 15'
SCALE: 1" = 15'
INSET MAP
JO
SH
U A
S.
B
LA
C
K
G4
G5
G3
G3
G5
G4
G5
G5
G5
R
EA
D Y
TO
B
ID
S
ET
G1 66
G6
A.4
A B C D
A B C D
B.1 B.2 B.8 B.9
1.2
1.6
1.7
1.2
1.6
1.7
A.4 B.1 B.2 B.8 B.9
WWWWWWWW
W
6'' S
D
GB
GB
3.
0%
6" SEWER LINE
FL OUT: 64.38 (E)
0.7%
3.
0%
2.0%
2.1%
1.
1%
0.7%
2.
1%
2.3%
2.8%
0.7%
3.
0%
3.
0%
1.
5%
0.
0%
1.
5%3.
0%
1.6%
2.
5%
1.
5%
2.0%
2.
0%
2.0%
3.
0%
3.6%
0.7%
2.
0%
2.0%
0.0%
0.0% 0.0%
6" SD PIPE
FL OUT: 64.38 (S)
2.7%
2.5%
2.
0%
3.
0%
5.
5.
2.
TA: 65.88
TA: 65.91
TA: 65.87
TA: 65.90
TA/TC: 65.82
TA/TC: 65.82
TA/TC: 65.92
TA/TC: 65.92
TA/TC: 65.93
TA/TC: 65.93
TA/TC: 65.93
TA/TC: 65.93
TC: 65.40 TC: 65.15
TA/TC: 65.93
TA: 65.93
TA: 66.29
TA: 66.38
TA: 66.38
TW: 67.93
TC: 66.46
TW: 67.93 TW: 67.93
TW: 67.93
TC: 65.76TC: 65.76
TC: 65.76
TC: 65.47 TW: 66.88
A.4 16.67'24.58'
1.54'
2.4'
17.5'
2.4'
4'
0.75'
8'
.2 5'
2.
A B C D
A B C D
4.75'
8.
1.5'
B.1 B.2 B.8 B.9
1.2
1.6
1.7
1.2
1.6
1.7
A.4 B.1 B.2 B.8 B.9
N:3707150.10 E:1504758.04
N:3707194.42 E:1504724.68
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
CAUTION: NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS
IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,
WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT
LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. IF A
CONFLICT IS IDENTIFIED, THE ENGINEER OF RECORD SHOULD BE
CONTACTED IMMEDIATELY, PRIOR TO ANY FURTHER WORK BEING DONE
RELATED TO THE ISSUE.
BR
IG
H
AM
C
IT
Y M
AI
N
T.
S
IT
E
IM
PR
O V.
BR
IG
H
AM
C
IT
Y, B
O X
EL
D
ER
C
O U
N
TY
U T-
-1
TB
D
R
EG
IO
N
7/
/2
JBD
W
CG-2
W
AS
H R
AC
K
EN
LA
R G
ED
P
LA
N
H
O R R O C K
S
E
N G I N E E R
S
0 5' 10'
SCALE: 1" = 10'
N G3
2-
NOTES
1. SPOT ELEVATIONS SHOWN REFERENCE A BASE ELEVATION OF 4500
FEET.
Q
\U T-
-1
U
D O
T M ai nt en an ce s ite R eh ab
\P ro je ct
D at a\
C
AD
\2 .0
Sh ee t F ile s\
C on st ru ct io n D ra w in gs
\U T-
-1
BR
IG
H
AM
C
IT
Y
Ju ly
3, TW
EL=67.93
TW
EL=67.93
TW
EL=67.93
2.5%
FG
EL=VARIES
BF
EL=64.32
0.7% 1.6%
FG
EL=VARIES
TW
EL=67.93
FG
EL=66.38 TC
EL=65.76
BF
EL=61.38
BF
EL=61.38
BF
EL=62.65
FG
EL=VARIES
SCALE:
WASH RACK N-S SECTION
NTS
SCALE:
WASH RACK E-W SECTION
NTS
CONSTRUCTION KEYNOTES:
WASH RACK FOUNDATIONS, SEE STRUCTURAL
CONCRETE STOOP, SEE STRUCTURAL
TRUCK WASH BANDED MAT SLAB, SEE
STRUCTURAL
CONCRETE WALL / FOOTING, SEE STRUCTURAL
ALUMINUM HAND PULL GATE (SEE DETAIL 2 SHEET
DT-4)
WASH RACK ELEVATED STRUCTURE (SEE
STRUCTURAL). SEE DETAILS 1 & 2 SHEET DT-7 FOR
ELEVATED WASH RACK COLD WATER PIPING,
VALVES, FITTINGS, ETC.
SCALE:
WASH RACK ENLARGED PLAN
NTSSCALE:
GRID DIMENSIONS
NTS
21 TYP
G1
21TYP
7/21/21
7/
/2
JS
B
6" STORM LINE
G4
GRADING KEYNOTES:
GRADING LOW POINT
GRADING HIGH POINT
GRADE BREAK
DRAINAGE PATH/SWALE
MATCH EXISTING ELEVATION
G1
G2
G3
G4
G5
SUMP
EL=62.38
SLAB EDGE
EL=65.15
BF
EL=62.65
BF
EL=62.43
3.0%
TA/TC
EL=65.82
TA/TC
EL=65.93
2.0%
JO
SH
U A
S.
B
LA
C
K
R
EA
D Y
TO
B
ID
S
ET
23 23
G3
TW
EL=66.88
10'' SD
toe toe toe to e to e to e to e to e to p to p to p to p to p to p to p to p to p to p to p to ptoptop pp pp pp e jb s s co to e
15'' SD
'' S
D
6'' S D
6'' SD
SD
S
FI
LL
FI
LL
FILL FILL FILL FILL FILL
TO
P
TOP
TOP
TOP
TOP
TO
P
TO
P
TOP
TOP
TOP
G B
G B
G B
TOE
TOE
TO
E
TOE
TOE
TO
E
TOP
TOP
HWM
HWM
HW
MHWM
H W
M
CO
FILL
FILL
FILL
GB
GB
C U
T C
U T
C U
T
SF
SF
SF
SF
SF
SF
SF
FEMA 100-YEAR FLOODPLAIN
BOUNDARY
FEMA 100-YEAR FLOODPLAIN
BOUNDARY
SEE POND NOTE 1
THIS SILT FENCE ONLY REQ'D IF
STAGING AREA IS ADJACENT TO CREEK
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
AP
PR
O
VE
D
SHEET NO.
U
TA
H D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
AT
E
R
EV
IS
IO
N S
R
EM
AR
KS
D
AT
E N
O
Q C
C H
EC
KE
D B
Y
PR
O
JE
C
T
PR
O
JE
C
T N
U M
BE
R
PI
N
PR
O
FE
SS
IO
N
AL
E
N G
IN
EE
R
SWPPP NOTES:
1. PLEASE REFERENCE SHEET G-3 FOR ADDITIONAL EROSION CONTROL NOTES.
2. EROSION CONTROL GRAPHICS ARE SCHEMATIC AND DO NOT REFLECT EXACT
PLACEMENT. ACTUAL PLACEMENT WILL BE DETERMINED IN FIELD.
3. SELECTION AND PLACEMENT OF EROSION CONTROL BMP'S CAN CHANGE BASED
ON FIELD CONDITIONS AND…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .