3A_-_Architectural_Plans_(A-001)_-_100%_-_4-11-25_.pdf

PDF 1 MB Posted

Attached to
Raw Water Booster Pump Station Improvements
Solicitation number
25-8400
Issued by
Collier County, Florida

About this file

This document is an architectural plan for the Raw Water Booster Pump Station Improvements project by Collier County Public Utilities located at 10600 Chevrolet Way, Estero, FL. The project involves three primary scopes of work: installing a potable water well and reverse osmosis (RO) system, upgrading an existing restroom, and converting a storage room into office space. The plan includes detailed specifications for a 4-inch well with a 1 HP - 20 GPM pump, HDPE water main, backflow preventer, hydro-pneumatic tank, RO water treatment system, and associated electrical and permitting requirements.

The project encompasses comprehensive renovations including demolition of a concrete ramp, installation of new air conditioning and electrical systems, painting of ceilings, walls, and floors in colors to be approved by the county, and furnishing office space. The contractor is responsible for all labor, equipment, materials, and incidentals, with specific requirements for system installation, water testing, disinfection, and a three-year warranty on all parts and labor. All work must comply with Collier County and state permits, with the project marked as a 100% submittal under Engineering Business No. 2429.

View the file

Other files

File Type Posted
100%_Specifications_10-13-25_.pdf PDF
Image_1.JPG JPG image
Image_1.JPG JPG image
Image_2.JPG JPG image
3A_-_Architectural_Plans_(A-001)_-_100%_-_9-25-25.pdf PDF
100%_Specs_9-25-25.pdf PDF
3A_-_Architectural_Plans_(A-001)_-_100%_-_9-25-25.pdf PDF
3A_-_Architectural_Plans_(A-001)_-_100%_-_9-25-25.pdf PDF
100%_Specs_9-25-25.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
25-8400_-_Authorization_to_Advertise.pdf PDF
25-8400_-_Authorization_to_Advertise.pdf PDF
25-8400_-_Authorization_to_Advertise.pdf PDF
25-8400_Specs.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
25-8400_Bid_Schedule.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
25-8400_Bid_Schedule.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
4_-_Plumbing_Plans_-_100%_-_4-9-25_.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
25-8400_Bid_Schedule.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
4_-_Plumbing_Plans_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
5_-_Mechanical_-_100%_-_4-9-25_.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
5_-_Mechanical_-_100%_-_4-9-25_.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELECTRIC ROOM

GENERATOR ROOM

ELECTRIC ROOM

PUMP ROOM

RESTROOM

FUEL TANK

OFFICE

ELECTRIC ROOM

NOTES

CHKD:

DRWN:

PROJ:

DESN:

w w w t e t r a t e c h c o m

M A

R K

D A

T E

D E

S C

R I P

T I O

N B

Y

A

M

O

P

R O

J E

C T

S O

R L

A N

D O

I E

R

C

A D

S

H E

E T

F I L

E S

A

E

X I S

T I N

G

B

U I L

D I N

G D

W G

M

A R

Q U

E Z

G

E R

M A

I N

A

B

C

D

E

F

2 3 4 5 6 7

Bar Measures 1 inch, otherwise drawing not to scale

C o p y r i g h t

T e t r a

T e c h

200-08486-24001

R A

W

W

A T

R

B

O O

S T

R

P

U M

P

S

T A

T I O

N

I M

P R

O V

E M

E N

T S

C O

L L

I E

R

C

O U

N T

Y

P

U B

L I C

U

I L

I T

I E

S

C

H E

V R

O L

W

A Y

S

U I T

E

E S

T E

R O

F

L

P H

100% SUBMITTAL

N

G I N

E E

R I N

G

B

U S

I N

E S

S

N

O

A-001

E X

I S

T I N

G

P

U M

P

B

U I L

D I N

G

N

SCALE:

4' 8' 16'

1/8" = 1'-0''

PLAN

SCALE: 1/8"=1'-0"

PHOTO

SCALE: N.T.S.

PHOTO

SCALE: N.T.S.

PHOTO

SCALE: N.T.S.

PHOTO

SCALE: N.T.S.

PHOTO

R.O. SYSTEM TO BE

INSTALLED IN THIS

CORNER (SEE NOTE 1)

STORAGE ROOM TO BE

CONVERTED TO OFFICE

SPACE (SEE NOTE 3)

RESTROOM TO BE

UPGRADED (SEE NOTE 2)

PHOTO

PHOTO

PHOTO

1. POTABLE WATER WELL AND REVERSE OSMOSIS (RO) SYSTEM - THE

POTABLE WATER SYSTEM WILL BE USED FOR THE UPGRADE TO THE

EXISTING RESTROOM, WHICH INCLUDES AN EXISTING TOILET, EXISTING SINK,

AND A NEW SHOWER. THE CONTRACTOR, THROUGH A QUALIFIED POTABLE

WATER WELL DRILLER LICENSED IN THE STATE OF FLORIDA, SHALL PROVIDE

A TURNKEY POTABLE WATER SYSTEM, INCLUDING BUT NOT LIMITED TO:

A.THE FINAL LOCATION AND INSTALLATION OF A 4-INCH WELL WITH A 1 HP -

20 GPM PUMP.

B.1-INCH HDPE WATER MAIN AND VALVES.

C.BACK FLOW PREVENTER.

D.HYDRO-PNEUMATIC TANK.

E.REVERSE OSMOSIS (RO) WATER TREATMENT SYSTEM.

F. CONNECTION TO THE BUILDING INTERIOR POTABLE WATER SYSTEM.

G.DISINFECTION.

H. WATER TESTING.

I. ELECTRICAL FROM THE BUILDING TO THE WELL.

J. DRILLING SLURRY CLEANUP.

K. START UP AND TESTING OF THE SYSTEM

L. 3 YEAR WARRANTY ON ALL PARTS AND LABOR.

M.ALL COLLIER COUNTY AND STATE PERMITS.

2. RESTROOM UPGRADE - THE CONTRACTOR SHALL PROVIDE ALL LABOR,

EQUIPMENT, MATERIALS, AND INCIDENTALS TO UPGRADE THE RESTROOM,

WHICH INCLUDES AN EXISTING TOILET, EXISTING SINK, AND A NEW SHOWER,

INCLUDING BUT NOT LIMITED TO:

A.INSTALLATION OF A NEW SHOWER AND HOT WATER HEATER.

B.DEMOLITION OF EXISTING PLUMBING PER THE PLUMBING PLANS AND

SPECIFICATIONS.

C.INSTALLATION OF PLUMBING PER THE PLUMBING PLANS AND

SPECIFICATIONS.

D.INSTALLATION OF THE SHOWER/RESTROOM VENTILATION SYSTEMS PER

THE MECHANICAL PLANS AND SPECIFICATIONS.

E. INSTALLATION OF ALL LIGHTING AND ELECTRICAL PER THE ELECTRICAL

PLANS AND SPECIFICATIONS.

F. CLEAN THE CEILING AS REQUIRED TO PROVIDE TWO (2) COATS OF PAINT IN

COLORS TBD AND APPROVED BY THE COUNTY.

G.CLEAN THE WALLS AS REQUIRED TO PROVIDE TWO (2) COATS OF PAINT IN

COLORS TBD AND APPROVED BY THE COUNTY.

H.CLEAN THE FLOOR AS REQUIRED TO PROVIDE TWO (2) COATS OF FLOOR

PAINT IN COLORS TBD AND APPROVED BY THE COUNTY.

3. STORAGE ROOM CONVERTED TO OFFICE SPACE - THE CONTRACTOR SHALL

PROVIDE ALL LABOR, EQUIPMENT, MATERIALS, AND INCIDENTALS TO

CONVERT THE EXISTING STORAGE ROOM TO OFFICE SPACE, INCLUDING BUT

NOT LIMITED TO:

A.DEMOLITION OF THE EXISTING CONCRETE RAMP.

B. INSTALLATION OF AIR CONDITIONING SYSTEM PER THE MECHANICAL

PLANS AND SPECIFICATIONS.

C.INSTALLATION OF ALL LIGHTING AND ELECTRICAL SYSTEMS PER THE

ELECTRICAL PLANS AND SPECIFICATIONS.

D.CLEAN THE CEILING AS REQUIRED TO PROVIDE TWO (2) COATS OF PAINT IN

COLORS TBD AND APPROVED BY THE COUNTY.

E. CLEAN THE WALLS AS REQUIRED TO PROVIDE TWO (2) COATS OF PAINT IN

COLORS TBD AND APPROVED BY THE COUNTY.

F. CLEAN THE FLOOR AS REQUIRED TO PROVIDE TWO (2) COATS OF FLOOR

PAINT IN COLORS TBD AND APPROVED BY THE COUNTY.

G.FURNITURE PER THE SPECIFICATIONS.

H.THE COUNTY WILL REMOVE ALL THE EXISTING EQUIPMENT IN THE STORGE

ROOM.

CONCRETE

RAMP TO BE

DEMOLISHED

CONCRETE RAMP

TO BE DEMOLISHED

Sheets and Views
G-000 COVER SHEET
G-001 LOCATION MAP, GENERAL NOTES, AND DRAWING INDEX
G-002 LEGENDS AND ABBREVIATIONS
C-101 GENERAL SITE PLAN
C-102 EXISTING YARD PIPING PLAN
C-103 EXISTING FLOW METER PIPING AND DEMOLITION PLAN & SECTION
C-104 PROPOSED FLOW METER PIPING PLAN & SECTION
C-501 CIVIL DETAILS
C-502 CIVIL DETAILS
A-001 EXISTING PUMP BUILDING