36L79723Q0009 0001_1.docx
DOCX document 30 KB Posted
- Attached to
- 3695--Washer Extractors & Semi Automatic Cart Washer/Dryer Fayetteville, AR Federal contract opportunity
- Solicitation number
- 36L79723Q0009
- Issued by
- Department of Veterans Affairs
About this file
This is an amendment to a solicitation issued by the Department of Veterans Affairs seeking washer extractors, a semi-automatic cart washer/dryer, and related services for the Fayetteville Veterans Affairs Medical Center in Fayetteville, Arkansas. The amendment changes the set-aside classification from a sole source Service-Disabled Veteran-Owned Small Business set-aside to an open SDVOSB set-aside. It also provides answers to questions submitted by interested parties regarding requirements for diamond plate, an uninterrupted power supply, and incorporates an addendum and list of deliverables as attachments. The response deadline is January 19, 2024 at 3:30pm Central Time. Interested parties should review the attachments for full requirement details.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ATTACHMENT B - LIST OF DELIVERABLES.docx | DOCX document | |
| ATTACHMENT A - ADDENDUM FAR 52.212-4.docx | DOCX document | |
| 36L79723Q0009_2.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36L79723Q0009 Amendment 0001
| SUBJECT* |
| Washer Extractors & Semi Automatic Cart Washer/Dryer Fayetteville, AR |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 60141 |
| SOLICITATION NUMBER* |
| 36L79723Q0009 |
| RESPONSE DATE/TIME/ZONE |
| 01-19-2024 3:30 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 3695 |
| NAICS CODE* |
| 333310 |
| CONTRACTING OFFICE ADDRESS |
| National Acquisition Center |
1 Block North of 22nd St Building 37 Hines, IL 60141
POINT OF CONTACT*
Monique Lara, Contract Specialist Monique.Lara@va.gov 708-786-4987
PLACE OF PERFORMANCE
| ADDRESS |
| Fayetteville Veterans Affairs Medical Center |
1100 North College Avenue
Building 9
Fayetteville, AR
| POSTAL CODE |
| 72703-1944 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
DESCRIPTION
| *= Required Field |
| Amendment to a Previous Combined Solicitation |
Page 1 of
Amendment to a Previous Combined Solicitation
Combined Synopsis Solicitation is hereby amended as follows:
1) Change classification:
FROM: Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Sole Source (FAR 19.14) TO: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
2) Provide answers to questions submitted by interested parties,
3) Incorporate Attachment A - Addendum to FAR 52.212-4, and
4) Incorporate Attachment B - List of Deliverables.
Question 1.
Can a copy of the “List of Deliverables” section that applies to the Solicitation 36L79723Q0009 be provided for review and incorporation into the formal solicitation response?
Answer 1.
Refer to Attachment B, List of Deliverables.
Question 2.
There is no trench currently installed at VAMC Fayetteville and the drain piping for the washer/extractors is through floor piping. Please validate that since there is no trench present onsite it is acceptable to exclude the above referenced diamond plate from the project requirements.
Answer 2.
Technical Specification subsection #25 on page 4 has been removed in its entirety.
Question 3.
Typically, an Uninterrupted Power Supply is not required for washer extractors and gas heated tumblers. The inclusion of this requirement could significantly increase cost and scope of the project and provide limited operational benefit. Please validate if in this instance an Uninterrupted Power Supply is only a requirement for the Washer Control System?
Answer 3.
The Uninterrupted Power Supply (UPS) requirement is applicable to the Wash System Controls. Refer to the updated Statement of Work section 5.4.5.
FROM: 5.4.5. Uninterrupted Power Supply (UPS) shall be installed for all equipment supplied. (Minimum 2-hour back-up).
TO: 5.4.5. Uninterrupted Power Supply (UPS) shall be installed for Wash System Controls. (Minimum 2-hour back-up).
See attached document: ATTACHMENT A - ADDENDUM FAR 52.212-4.
See attached document: ATTACHMENT B - LIST OF DELIVERABLES.
Page 1 of Page 1 of
File details come from the government source that posted it. Updated .