This document contains a federal contract opportunity solicitation for construction services. The Department of Veterans Affairs seeks to award a firm-fixed-price contract to construct a new 10,930 square foot warehouse facility to replace outdated buildings at the Prescott VA Medical Center in Arizona. The warehouse will provide conditioned storage space and accommodate efficient loading and material storage critical to supply chain operations. The site work will include over 30,000 square feet of paving and 5,000 square feet of hardscaping. The solicitation will be a Request for Proposal evaluated using Lowest Price Technical Acceptable procedures, set aside for a Service-Disabled Veteran-Owned Small Business, with a size standard of $39.5 million. The anticipated contract value is between $5-10 million. The period of performance is 360 calendar days from notice to proceed. The solicitation is expected to be issued on July 27, 2020 with all questions due to the specified email by the issuing office.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1" GYPSUM SHAFT-LINER
6" I-STUD @ 24 O.C., 20 GUAGE
5/8" TYPE 'X' GYPSUM
WALLBOARD ON UNDERSIDE OF
FIRE-RATED CEILING ASSEMBLY
UL EVALUATION REPORT (ER) R3501-02
J-TRACK
1" GYPSUM SHAFT-LINER
6" I-STUD @ 24 O.C., 20 GUAGE
5/8" TYPE 'X' GYPSUM
WALLBOARD ON UNDERSIDE OF
FIRE-RATED CEILING ASSEMBLY
UL EVALUATION REPORT (ER) R3501-02
J-TRACK
• THE I-STUDS ARE SUPPORTED BY J-TRACKS THAT ARE ATTACHED TO VERTICAL WALL FRAMING MEMBERS USING MECHANICAL FASTENERS SPACED A MAXIMUM OF 24 INCHES (610 MM) ON CENTER. THE FASTENERS MUST HAVE A MINIMUM ALLOWABLE LOAD OF 200 POUNDS (889.6 N) IN SHEAR OR PULLOUT. THE I-STUDS ARE ATTACHED TO THE J-TRACKS AT EACH END USING TWO
1/2 INCH (12.7 MM) TYPE S PAN HEAD SCREWS.
R E
F E
R T
O P
A R
T
IT
IO
N
T Y
P E
S F
O R
W A
LL
H
E
IG
H T
FIRE SEALANT
5/8" TYPE 'X' GYPSUM WALLBOARD ON EACH
SIDE OF METAL STUD, REFER TO PLAN AND
PARTITION TYPES FOR MORE INFORMATION.
5/8" TYPE 'X' GYPSUM WALLBOARD ON EACH
SIDE OF METAL STUD, REFER TO PLAN AND
PARTITION TYPES FOR MORE INFORMATION.
FIRE SEALANT
FIRE SEALANT
FIRE-RATED CEILING ASSEMBLY DETAIL
| Drafting Views (LEGEND) |
| FIRE-RATED CEILING ASSEMBLY DETAIL |