Item 81 response_Fire-rated Ceiling Assembly Detail.pdf

PDF 57 KB Posted

Attached to
Y1GZ--Construct Replacement Warehouse Prescott VAMC (Minor Construction) Federal contract opportunity
Solicitation number
36E77620R0043
Issued by
Department of Veterans Affairs Headquarters

About this file

This document contains a federal contract opportunity solicitation for construction services. The Department of Veterans Affairs seeks to award a firm-fixed-price contract to construct a new 10,930 square foot warehouse facility to replace outdated buildings at the Prescott VA Medical Center in Arizona. The warehouse will provide conditioned storage space and accommodate efficient loading and material storage critical to supply chain operations. The site work will include over 30,000 square feet of paving and 5,000 square feet of hardscaping. The solicitation will be a Request for Proposal evaluated using Lowest Price Technical Acceptable procedures, set aside for a Service-Disabled Veteran-Owned Small Business, with a size standard of $39.5 million. The anticipated contract value is between $5-10 million. The period of performance is 360 calendar days from notice to proceed. The solicitation is expected to be issued on July 27, 2020 with all questions due to the specified email by the issuing office.

View the file

Other files for this federal contract opportunity

Other files attached to Y1GZ--Construct Replacement Warehouse Prescott VAMC (Minor Construction), newest first.
File Type Posted
36E77620R0043 0006.docx DOCX document
Technical Questions Tracking Sheet - 09-14-2020.pdf PDF
36E77620R0043 0005.docx DOCX document
1395.26_Revised Roof Slope Sketch.pdf PDF
Telecom Specs1.pdf PDF
Technical Questions Tracking Sheet - 09-09-2020.pdf PDF
Construction Wage Rates - Yavapai - 08-21-2020.pdf PDF
Monitoring and Discovery Protocol.pdf PDF
Item 70 response_Drawing-Montage Commercial Classic.pdf PDF
07 43 00 Wall and Roof Panels.pdf PDF
36E77620R0043 0004.docx DOCX document
Item 69 response_Drawing-Montage Commercial Classic Gate.pdf PDF
1395.26 Construct Replacement Warehouse_ASI 002 Narrative.pdf PDF
01 00 00 - General Requirements.pdf PDF
10 26 00 Wall Protection.pdf PDF
Reference C - Question 112 - 067 165-M-301 MECHANICAL SECTIONS AND ENLARGED.pdf PDF
Reference E - Question 113 - DIV 13 SPECIAL CONSTRUCTION.pdf PDF
Reference D - Question 113 - 026 165-SA-001 STRUCTURAL GENERAL NOTES.pdf PDF
S05 - Technical Questions Tracking Sheet TO BE PUBLISHED 9-4.pdf PDF
36E77620R0043 0003.docx DOCX document
Technical Questions Tracking Sheet 36E77620R0043.pdf PDF
36E77620R0043 0002.docx DOCX document
36E77620R0043 - SITE VISIT SIGN IN SHEET - 08-11-2020.pdf PDF
36E77620R0043 0001.docx DOCX document
Attachment 15 - Construction Wage Rates - Yavapai - 06-05-2020.pdf PDF
Copy of Attachment 14 - Division Price Breakdown.xlsx XLSX spreadsheet
Attachment 7 - F Drawings.pdf PDF
Attachment 12 - T Drawings.pdf PDF
Attachment 10 - P Drawings.pdf PDF
Attachment 13 - Warehouse Building Soils Report.pdf PDF
Attachment 16 - Contractor Safety _ Env Record Form.docx DOCX document
Attachment 11 - S Drawings.pdf PDF
Attachment 8 - G Drawings.pdf PDF
Attachment 1 - Volume 01 Specifications REV.pdf PDF
Attachment 9 - M Drawings.pdf PDF
Attachment 4 - A Drawings.pdf PDF
Attachment 3 - Volume 03 Specifications REV.pdf PDF
Attachment 2 - Volume 02 Specifications.pdf PDF
36E77620R0043.docx DOCX document
Attachment 5 - C Drawings Part I.pdf PDF
Attachment 17 - Prescott Site Map.pdf PDF
Attachment 5 - C Drawings Part II.pdf PDF
Attachment 6 - E Drawings.pdf PDF
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1" GYPSUM SHAFT-LINER

6" I-STUD @ 24 O.C., 20 GUAGE

5/8" TYPE 'X' GYPSUM

WALLBOARD ON UNDERSIDE OF

FIRE-RATED CEILING ASSEMBLY

UL EVALUATION REPORT (ER) R3501-02

J-TRACK

1" GYPSUM SHAFT-LINER

6" I-STUD @ 24 O.C., 20 GUAGE

5/8" TYPE 'X' GYPSUM

WALLBOARD ON UNDERSIDE OF

FIRE-RATED CEILING ASSEMBLY

UL EVALUATION REPORT (ER) R3501-02

J-TRACK

• THE I-STUDS ARE SUPPORTED BY J-TRACKS THAT ARE ATTACHED TO VERTICAL WALL FRAMING MEMBERS USING MECHANICAL FASTENERS SPACED A MAXIMUM OF 24 INCHES (610 MM) ON CENTER. THE FASTENERS MUST HAVE A MINIMUM ALLOWABLE LOAD OF 200 POUNDS (889.6 N) IN SHEAR OR PULLOUT. THE I-STUDS ARE ATTACHED TO THE J-TRACKS AT EACH END USING TWO

1/2 INCH (12.7 MM) TYPE S PAN HEAD SCREWS.

R E

F E

R T

O P

A R

T

IT

IO

N

T Y

P E

S F

O R

W A

LL

H

E

IG

H T

FIRE SEALANT

5/8" TYPE 'X' GYPSUM WALLBOARD ON EACH

SIDE OF METAL STUD, REFER TO PLAN AND

PARTITION TYPES FOR MORE INFORMATION.

5/8" TYPE 'X' GYPSUM WALLBOARD ON EACH

SIDE OF METAL STUD, REFER TO PLAN AND

PARTITION TYPES FOR MORE INFORMATION.

FIRE SEALANT

FIRE SEALANT

FIRE-RATED CEILING ASSEMBLY DETAIL

Drafting Views (LEGEND)
FIRE-RATED CEILING ASSEMBLY DETAIL