ATTACHMENT 3 - Drawings 2 of 2.pdf
PDF 23 MB Posted
- Solicitation number
- 36E77620B0005
About this file
This notice provides information about an upcoming federal contract opportunity for renovation and relocation services at the Robert J. Dole VA Medical Center in Wichita, Kansas. The Department of Veterans Affairs intends to solicit proposals for a firm-fixed-price design-build contract valued between $2-5 million to renovate the first floor for oncology, hematology, and dialysis services. The work includes general construction, site work, and removal of existing structures. The solicitation will be issued as an Invitation for Bid and evaluated based on lowest price from SDVOSB concerns. The performance period is approximately 270 days from notice to proceed. Questions must be submitted in writing by mid-June 2020.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A5077 A5078
CORNER GUARDS
HANDRAIL / WALLGUARD
CORNER GUARDS
HANDRAIL / WALLGUARD
RB
A5077
(OPEN)
1' - 0"
E0954
M4020 X9910 X9910
F3053
M1620 M1620 A5077A5077
CORNER GUARDS
HANDRAIL / WALLGUARD
CORNER GUARDS
HANDRAIL / WALLGUARD
CORNER GUARDS
GYP BD COLUMN
FURROUT
F3051
3"
F3052
3"
2' - 10 1/2" 2' - 10 1/2" 2' - 0"
7' - 9"
F3200
CORNER
GUARDS
IN
PT-3
E0954
FURR-DN
EQ EQ
" A5107
A5107 A5107
1' - 0 1/2"3' - 0"3' - 4"4' - 0"
A1015
A1015
C0046 C06M0 C06M0 C0045
CORNER
GUARDS
D9280
IN
IN
IN
1/4" TEMPERED
GLASS
LAY-IN CEILING
M4267
A1107M0505 M0765
A5077
A5078
A51454"2" 1
CD021
A5105
A5107
A5075
A5080
A5107
P3101
IN
IN
FURR-DN
EXIST WINDOW
BEYOND
CURTIAN
TRACK
F3200
PT-3 PT-3
FURR-DN
A1107
M0765
M0505
A5145
A5105
CD021
IN
F3200
M0755 M0750M4267
M1405
FURR-DN
A5180
M4116
M4267 M4267
M4116
PT-3
PT-3
A5105
A5107
CD021
M0505M0765A1107
A5145
IN
F3200
FURR-DN
A5105
CD021
IN
A5108
" A5107
A5107 A5107
EQEQ
FURR-DN
(OPEN)
A5078 A5077
A5145
M0505
M0765 A1107
F3200
M0755M0750
A5108
CORNER
GAURD
A1066 A5075
P3100
P9050
ADA GRAB
BARS
A5107
WT-2
WT-1
A5180
CD021A1107 M0755
M0505 A5107 A5105
IN
F3200
M0765
M0750
M4267
FURR-DN
A5078 A5077 A5077
A5078
A5180 A5180
A5077
A5078
A5080 A5075
P3101
A5077
A5078
M1620 A5077 A5077
A5078
IN
CHEMO TREAT. CHEMO TREAT.
INFUSION BAY
FURR-DN
M3110
HANDRAIL /
WALLGUARD
2' - 3 3/8" 3' - 0"
IN
IN
CORNER GAURD
GUARD/HANDRAIL
BUMPER GUARD
REF 12/IN210
A5180
2' - 1" 2' - 6" 2' - 6"
2' - 6" 1' - 5" 2' - 1" 2' - 6" 2' - 6"
A5180 A5180
A5080 A5075
CS150
R4100
F2015
A5077
A5078
IN
1/4" TEMPERED
GLASS
1/4" TEMPERED
GLASS
COLUMN FURG
COLUMN
FURG
(NURSE
STATION)
(INFUSION
BAY) (CHEMO
TREATMENT)
(NURSE
STATION)
FURR-DN
HANDRAIL /
WALLGUARD
CORNER
GUARDS TYP.
K4665
K1552
R6200 C03F0 C03G0C03F0 3
A5080A6046 FURR-DN
M1801
M1802
A5107
A5080
A5075
3' - 0"
IN
FURR DN
PT-3
A5180
M1802
M1801
A1014 A5146
"5
M4200
M1802
A1132
F3200
A5078
EQ EQ EQ EQ
IN
PT-3
FURR-DN
11' - 5 1/4"
11 3/4"
3' - 0" 3' - 4 3/4" 4' - 0"
A1015
A1015
F3200 C06M0
C0046C0045
D9280
IN
IN
IN
EQ EQ EQ
REFERENCE AE213
FOR MILLWORK
SECTIONS
REFERENCE IN102 FOR
COUNTERTOP AND
BACKSPLASH FINISHES
GUARDRAIL
5/8" GYP. BD. ON 3 5/8"
METAL STUDS
RUBBER BASE
REF. FINISH SCHED.
FLOORING
REF. FINISH SCHED.
LAY-IN CEILING TILES
AND GRID SYSTEM
LAY-IN CEILING
GYP. BD. WALL AND
COLUMN BEYOND
RECESSED ALUMINUM TRACK
ATTACHED TO METAL STUD
TRACK TO RECIEVE GLASS
RECESSED ALUMINUM TRACK
ATTACHED TO METAL HEADER
STUD TRACK TO RECIEVE GLASS
A5107 A5107 A5107 C06M0
A1066 A5180
E0945
A5107
A1014
M4200
A5078 M1801
E0945
A1107
A5146 M0755 M0765
M0750
A5145
CG
F3200
PT-3
CG
A5080
A5075
A5180
3' - 0"
IN
FURR-DN
A5105
A5090
A1017
A5200
A5080
P9050
ADA GRAB
BARS
CG
A1066
P3100
WT-1
WT-2
A5145
CG
A5107
A1017
A5200
A5090
ADA GRAB
BARS
CG
A5080
A5075
EXIST. WINDOWS
RETURN TILE TO WINDOWS
ADA GRAB
BARS
INTERIOR ELEVATION NOTES
1. REF: FOR TYPICAL TOILET WALL ELEVATIONS.
2. REF: MEP DRAWINGS FOR SPECIFIC ELEC. INFORMATION.
3. CORNER GUARDS TYPICAL, REFER SPECIFICATIONS.
4. REF: AE / 401 FOR EQUIPMENT SCHEDULE
5. ALL CABINETS L1 UNLESS NOTED OTHERWISE.
6. ALL COUNTERTOPS SS1 UNLESS NOTED OTHERWISE.
7. ALL WALL PT-2 FIELD COLOR UNLESS NOTED OTHERWISE.
8. MILLWORK CONTRACTING SUB TO VERIFY ALL SPACES
BEFORE SUBMITTING SHOP DRAWINGS.
/28 IN203
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
Wichita, KS
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSULTANT
B
IM
/1
-V A
W
IC
H
IT
A /V
A
W ic h it a
C e n tr a l.
rv t
/2
/2
:5
:5
P
M
IN202
INTERIOR ELEVATIONS
Prime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
589A7-19-401
Building 1
Conrad Pierce General Engineer/COR
2020.05.15 BJM JRC
0 2' 4' 8'
1/4" = 1'-0" 1/4" = 1'-0"1
CORRIDOR 141 EAST
1/4" = 1'-0"2
CORRIDOR 141 WEST
1/4" = 1'-0"3 NURSE STATION 178-a
1/4" = 1'-0"4 NURSE STATION 178-b
1/4" = 1'-0"5
CHEMO TRTMT 186 SOUTH
1/4" = 1'-0"6
CHEMO TRTMT 186 WEST
1/4" = 1'-0"7
CHEMO TRTMT 185 EAST
1/4" = 1'-0"8
CHEMO TRTMT 182 NORTH
1/4" = 1'-0"9
CHEMO TRTMT 182 EAST
1/4" = 1'-0"10
CHEMO TRTMT 182 SOUTH
1/4" = 1'-0"11
CHEMO TRTMT 182 WEST
1/4" = 1'-0"12
CHEMO TLT 180 NORTH
1/4" = 1'-0"14
CHEMO TLT 180 SOUTH
1/4" = 1'-0"15
CHEMO TRTMT 177 SOUTH
1/4" = 1'-0"16
CORRIDOR 168 EAST
1/4" = 1'-0"17
CORRIDOR 168 WEST
1/4" = 1'-0"18
EXAM 167 NORTH
1/4" = 1'-0"19
EXAM 167 EAST
1/4" = 1'-0"20
EXAM 167 SOUTH
1/4" = 1'-0"21
EXAM 167 WEST
1/4" = 1'-0"22
NURSE STATION 165 NORTH
1/4" = 1'-0"23
NURSE STATION 165 SOUTH
1/4" = 1'-0"24
PROC RM 160 NORTH
1/4" = 1'-0"25
PROC RM 160 EAST
1/4" = 1'-0"26
PROC RM 160 SOUTH
1/4" = 1'-0"27
PROC RM 160 WEST
1/4" = 1'-0"13
CHEMO TLT 180 EAST
1/4" = 1'-0"28
CHEMO TLT 160A NORTH
1/4" = 1'-0"29
CHEMO TLT 160A EAST
1/4" = 1'-0"30
CHEMO TLT 160A SOUTH
1/4" = 1'-0"31
CHEMO TLT 160A WEST
Revisions: Date:
5/15/20
M1802
M1801
A5180
"A5146
A5145
A1132
M4200
A5078
A5080 A5075
A5107
IN
FURR-DN
F3200
E0948
A5107
A5080
M1802
FURR-DN
PT-3
M1801
M1802
A5180
E0948
A1014
A5146
IN
F3200
EQ EQ
1' - 2" 3' - 6"
1 3/8"
A5078
IN
CORNER GAURD
FURR-DN
A6046
M4200
A1132
A5080
M3072
M3072
A5108
A5107
F0205
M1802
E0948
PT-3
A5107 A5107
A5200A5080
ADA GRAB BARS
A5145
P9050
A5090
A5200
ADA GRAB
BARS
A5075
A1066
P3100
P9050A5090 ADA GRAB
BARS
A5107
"5
A1066
P3100
A5107P6350
A5080 A5075
P3100
A1107
M0505
M0765
PT-3
A5107
CD021
A5105
A5180
1' - 8"
M0505
F3200
FURR-DN
A5180
CD021
A5107
A5105
1' - 8"A1107
M0505
A5145M0765
M0755
FURR-DN
IN
5/8" GYP. BD.
COLUMN FURRING
CORNER GUARDS
WALL BASE
HANDRAIL /
GUARD RAIL
EQ EQ EQ
1/4" TEMPERED
BUTT GLAZING
1/8" OPEN GAP
BETWEEN GLASS
PANELS
LAY-IN CEILING
CORNER GUARD
RECESSED
ALUMINUM
TRACK TO
RECEIVE GLASS
M1620
A5077
HANDRAIL/ GUARDRAILWALL BASE TYPICAL,
AS SCHEDULED
4' - 0"
18 18
UL752 GLASS
COUNTER W/
BRACKETS
4' - 0"
LOCKABLE WINDOWS
PT-3
A5107
M3070
A5145
M7040
M4267
M1405
A5200
A5090
STALL DOOR WALL BEYOND
WT-2
WT-1
3' - 2" 4' - 9 1/8"
UL752 IMPACT
RESISTANT GLASS
7' - 9 3/4"
MASS WAITING
BEYOND
PT-3
INTERIOR ELEVATION NOTES
1. REF: FOR TYPICAL TOILET WALL ELEVATIONS.
2. REF: MEP DRAWINGS FOR SPECIFIC ELEC. INFORMATION.
3. CORNER GUARDS TYPICAL, REFER SPECIFICATIONS.
4. REF: AE / 401 FOR EQUIPMENT SCHEDULE
5. ALL CABINETS L1 UNLESS NOTED OTHERWISE.
6. ALL COUNTERTOPS SS1 UNLESS NOTED OTHERWISE.
7. ALL WALL PT-2 FIELD COLOR UNLESS NOTED OTHERWISE.
8. MILLWORK CONTRACTING SUB TO VERIFY ALL SPACES
BEFORE SUBMITTING SHOP DRAWINGS.
/28 IN203
SLIDING BULLET
RESISTANT WINDOWS
PT-3
PT-4
WT-1
WT-2
WT-1
F3200
1' - 6"
A5145
F2000
A5108
A5105
A5107
CD021
FURR-DN
A5077
A5078
M0755 M0765
M0750
A1107
M1405
M0505
M4267
A5145
M7040
M4267
M1405
M0505 PT-3F3200
A5105
A5107
A5108
A5180
F2000
PT-3
CD021
A1107 M0755
M0765 M0750
M4267
M7040
M0505
M14054
A5108
R6200
C01C0
CT020
A5099
A5107
F2010
EQ EQ EQ
LOCKABLE
UPPERS
IN
IN
3' - 0"
C04G0
M1801
M3150 M3150CT020
IN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
Wichita, KS
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSULTANT
B
IM
/1
-V A
W
IC
H
IT
A /V
A
W ic h it a
C e n tr a l.
rv t
/2
/2
:5
:1
P
M
IN203
INTERIOR ELEVATIONS
Prime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
589A7-19-401
Building 1
Conrad Pierce General Engineer/COR
2020.05.15 BJM JRC
1/4" = 1'-0"1
EXAM / TELEMED 143 NORTH
1/4" = 1'-0"2
EXAM / TELEMED 143 EAST
1/4" = 1'-0"3
EXAM / TELEMED 143 SOUTH
1/4" = 1'-0"4
EXAM / TELEMED 143 WEST
1/4" = 1'-0"5
EXAM RM 142 NORTH
1/4" = 1'-0"6
EXAM RM 142 EAST
1/4" = 1'-0"7
EXAM RM 142 SOUTH
1/4" = 1'-0"8
EXAM RM 142 WEST
1/4" = 1'-0"9
CHEMO TLT. 169 NORTH
1/4" = 1'-0"10
CHEMO TLT. 169 EAST
1/4" = 1'-0"11
CHEMO TLT. 169 SOUTH
1/4" = 1'-0"12
CHEMO TLT. 169 WEST
1/4" = 1'-0"13
SOILED STOR. 170 SOUTH
1/4" = 1'-0"16
INFUSION BAY 164 EAST
1/4" = 1'-0"17
INFUSION BAY 164 SOUTH
1/4" = 1'-0"18
CHEMO TRTMT 175 SOUTH
1/4" = 1'-0"19
CHEMO TRTMT 175 WEST
1/4" = 1'-0"20
CORRIDOR 168A NORTH
1/4" = 1'-0"21
CORRIDOR 168A SOUTH
1/4" = 1'-0"23
INTERVIEW EAST
1/4" = 1'-0"14
SOILED STORAGE NORTH
1/4" = 1'-0"15
INFUSION BAY NORTH
1/4" = 1'-0"25
WOMEN'S TLT 128 SOUTH
0 2' 4' 8'
1/4" = 1'-0"
1/4" = 1'-0"22
INTERVIEW NORTH
1/4" = 1'-0"24
INTERVIEW SOUTH
1/4" = 1'-0"26 Elevation 1 - a
1/4" = 1'-0"27 Elevation 2 - a
1/4" = 1'-0"28
TYPICAL TLT.
1/4" = 1'-0"29
INFUSION BAY 166.1 NORTH
1/4" = 1'-0"30
INFUSION BAY 166.1 EAST
1/4" = 1'-0"31
INFUSION BAY 166.1 SOUTH
1/4" = 1'-0"32
INFUSION BAY 166.1 WEST
1/4" = 1'-0"33
CHEMO TRTMT 179-1 NORTH
1/4" = 1'-0"34
CHEMO TRTMT 179-1 EAST
1/4" = 1'-0"35
CHEMO TRTMT 179-1 WEST
1/4" = 1'-0"39
MEDS 172-1 WEST
1/4" = 1'-0"38
MEDS 172-1 SOUTH
1/4" = 1'-0"37
MEDS 172-1 EAST
1/4" = 1'-0"36
MEDS 172-1 NORTH
2' - 0" 3/4"
/2
SINK & HARDWARE
REFER MEP
/2
M
IN
/2
MIN.
11"
M
IN
8"
1/2" SOLID
SURFACE,
WATERFALL EDGE
ON 3/4" PLYWOOD
REMOVEABLE
LOWER PANELS
O R
R E
F
E L
E V
SS BACKSPLASH RE:
ELEVATIONS
1 1/2" GROMMET
WALL BASE
/2
1/2" SOLID SURFACE,
WATERFALL EDGE ON
3/4" PLYWOOD
2' - 1" OR 1' - 6" AS NOTED
RE: PARTITION
TYPES
CONCEALED BRACKETS
@ 48" O.C. MAX
1/2"
8"
1/2" SOLID SURFACE,
WATERFALL EDGE ON 3/4"
PLYWOOD
1 1/2" GROMMET
WALL BASE
/2
/2
1/2" SOLID SURFACE,
WATERFALL EDGE ON
3/4" PLYWOOD
2' - 1" OR 14" AS NOTED
RE: PARTITION
TYPES
CONCEALED BRACKETS
@ 48" O.C. MAX (TYP.)
IMPACT RESISTANT WINDOWS,
REF: PLANS & ELEVATIONS
/4
/4
/2
/4
3/4" SUBSTRATE W/
LAMINATE TYP ON
EXPOSED SURFACES
BASE RE: SCHEDULE
ADJUSTABLE SHELVES
RE: PARTITION TYPES
1/2" SOLID SURFACE,
WATERFALL EDGE ON 3/4"
PLYWOOD
2' - 0 1/2" 1/2"
U P
T O
PROVIDE
WOODBLOCKING TYP.
/2
/2
3/4" SUBSTRATE W/
LAMINATE ON EXPOSED
SURFACES
BASE RE: SCHEDULE
ADJUSTABLE SHELVES
RE: PARTITION TYPES
1/2" SOLID SURFACE,
WATERFALL EDGE ON 3/4"
PLYWOOD
2' - 0 1/2" 1/2"
SS-1 REF: ELEVATIONS
/4
/4
/4
/2
WHITE
MELAMINE
INTERIOR TYP
3/4" X 3/4"
MAPLE
NOSING
1/2"
2' - 0 1/4"
O
R
R E
E
L E
V
SOLID SURFACE
COUNTERTOP ON
3/4" PLYWOOD
/4
/4
/4
/2 "1
/4
3"
3/4" SUBSTRATE W/
LAMINATE ON
EXPOSED
SURFACES
BASE RE:
SCHEDULE
1/2" SOLID SURFACE,
WATERFALL EDGE ON 3/4"
PLYWOOD
2' - 0 1/2" 1/2"
SS-1 REF: ELEVATIONS
WHITE MELAMINE
INTERIOR, TYP.
1' - 1"
V A
R
IE
S S
E E
E L E
V A
T
IO
N S
3/4" SUBSTRATE W/
LAMINATE ON
EXPOSED SURFACES
8'-0"
7'-0" MAX
METAL STUD AND GYP BD
FURR DOWN AT FRONT
AND SIDES OF UPPER
MILLWORK
1' - 1"
3/4" SUBSTRATE W/
LAMINATE ON
EXPOSED SURFACES
7'-0"
WHITE MELAMINE
INTERIOR
METAL STUD AND GYP BD
FURR DOWN AT FRONT
AND SIDES OF UPPER
MILLWORK
/4
/4 "6
/4
"1
/2
3"
3/4" SUBSTRATE W/
LAMINATE ON EXPOSED
SURFACES
SS COUNTERTOPS &
BACKSPLASH TYP RE:
ELEVATIONS
U P
T O
/4
/2
/4
3/4" SUBSTRATE W/
LAMINATE ON EXPOSED
SURFACES
BASE RE: SCHEDULE
RE: PARTITION TYPES
1/2" SOLID SURFACE,
WATERFALL EDGE ON 3/4"
PLYWOOD
2' - 0 1/2" 1/2"
LEVEL 1
0"
M
GYP BD WALL BEYOND
REFERENCE IN501 FOR
COUNTERTOP AND
BACKSPLASH FINISHES
DRYWALL EDGE TRIM
TO REINFORCE
CORNERS (TYP.)
GUARDRAIL/HANDRAIL
5/8" GYP. BD. ON 3 5/8"
METAL STUDS
RUBBER BASE
REF. FINISH SCHED.
FLOORING
REF. FINISH SCHED.
LAY-IN CEILING GRID
TRIM EDGES
LAY-IN CEILING TILES
AND GRID SYSTEM
LAY-IN CEILING TILES
LIGHTING - REF.
ELECTRICAL
METAL STUD TRACK
AND FRAMING RAN TO
DECK FOR SUPPORT
OF GLASS SYSTEM
GYP. BD. WALL AND
COLUMN BEYOND
GYP. BD. WALL AND
COLUMN BEYOND
RECESSED ALUMINUM
TRACK ATTACHED TO
METAL STUD TRACK TO
RECIEVE GLASS
RECESSED ALUMINUM
TRACK ATTACHED TO
METAL HEADER STUD
TRACK TO RECIEVE
GLASS
1/4" TEMPERED
BUTT-GLAZED
GLASS SYSTEM
1/4" TEMPERED
BUTT-GLAZED
GLASS SYSTEM
BUMPER RAIL
/2
3/4" SUBSTRATE W/
LAMINATE ON EXPOSED
SURFACES
BASE RE: SCHEDULE
ADJUSTABLE SHELVES
RE: PARTITION TYPES
3' - 0"
WHITE MELAMINE
INTERIOR
METAL STUD AND GYP BD
FURR DOWN AT FRONT
AND SIDES OF UPPER
MILLWORK
3/4" SUBSTRATE W/
LAMINATE ON EXPOSED
SURFACES
BASE RE: SCHEDULE
RE: PARTITION TYPES
3' - 0"
ONE PIECE
REMOVEABLE KICK
EQUIPMENT, SEE SHEET IN102
WHITE MELAMINE
INTERIOR
METAL STUD AND GYP BD
FURR DOWN AT FRONT
AND SIDES OF UPPER
MILLWORK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
Wichita, KS
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSULTANT
B
IM
/1
-V A
W
IC
H
IT
A /V
A
W ic h it a
C e n tr a l.
rv t
/2
/2
:5
:1
P
M
IN210
INTERIOR SECTIONS & DETAILS
Prime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
589A7-19-401
Building 1
Conrad Pierce General Engineer/COR
2020.05.15 BJM JRC
1" = 1'-0"1
ADA SINK
1" = 1'-0"3
DESK SECTION
1" = 1'-0"4
DESK & HIGH COUNTER
1" = 1'-0"5
TYP SECTION AT MILLWORK
1" = 1'-0"9
MILLWORK - DOORS
1" = 1'-0"2
MILLWORK - DOOR & DRAWER
1" = 1'-0"8
MILLWORK DRAWERS
1" = 1'-0"10
TYP. UPPER - DOORS
0 6" 1' 2'
1" = 1'-0"
1" = 1'-0"11
UPPER - DOORS
1" = 1'-0"6
MILLWORK - 3 DRAWERS 30"
1" = 1'-0"7
COUNTER W/ DRAWER
3/4" = 1'-0"12
NURSE STATION SECTION
6" 1'-6"1'0
1 1/2" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
1" = 1'-0"13
MILLWORK - DOORS FULL HEIGHT
1" = 1'-0"14
MILLWORK - DOORS FULL HEIGHT @ WARMING
SYMBOL MATERIAL VENDOR PATTERN / SIZE / COLOR REMARKS
FINISH SCHEDULE NOTE: ALL FINISHES TO BE APPROVED BY OWNER.
VERIFY W/ ARCHITECT PRIOR TO ORDERING MATERIAL.
BASE MATERIAL
WALL MATERIAL
MILLWORK MATERIAL
LUXURY VINYL TILE
FLOOR MATERIAL
NOTE:
1. PROVIDE SCHLUTER - JOLLY EDGE TRIM AT ALL EXPOSED EDGES OF TILE - SATIN SS.
2. PROVIDE SEAM TREATMENTS AT WAINSCOT AS NOTED.
3. PROVIDE 48" CORNER GUARDS AT CORNERS TYPICAL, SET ABOVE BASE FINISH, REFER SPECIFIACTIONS.
4. PROVIDE RUBBER BASE TYPICAL THROUGHOUT UNLESS NOTED OTHERWISE. REFER INTERIOR ELEVATIONS.
5. ALL WALLS PT-2 UNLESS NOTED OTHERWISE.
RSF-1
RSF-2
CP-1
RB
PT-1
SS1
L1
PT-2
WT-3
MOHAWK GROUP
CT-1
VCT-1
URBAN NATIVE WOOD - CARMELLO
LUXURY VINYL TILE
CARPET TILE MILLIKEN
CERAMIC TILE PORCELANOSA
ARMSTRONG
URBAN NATIVE WOOD - ZEN
RUBBER BASE SHAW CONTRACT 4" COVE BASE - NIGHT 0066
PLASTIC LAMINATE FORMICA CHESTNUT WOODLINE 5884
PAINT
PAINT
PAINT
PT-3
PT-5
LOBBY WALLS INPRO - PALLADIUM 3D TRIM
SHERWIN WILLIAMS SW 9166 DRIFT OF MIST
SHERWIN WILLIAMS
SHERWIN WILLIAMS
SHERWIN WILLIAMS
SW 7008 ALABASTER
SW 9177 SALTY DOG
SW 2848 ROYCROFT PEWTER
SOLID SURFACE HANSTONE METROPOLITAN
CEILING MATERIAL
AT ACOUSTICAL CEILINGS
PAINT
FIELD COLOR
WT-1 CERAMIC TILE SPECIALTY TILE
WT-2 ACCENT CERAMIC TILE TILEBAR ACCENT WALL TILE
VINYL COMPOSITION TILE
MOHAWK GROUP
WSF-1 SHEET FLOORING
OCEAN CERAMIC TILE - CALIZA
STANDARD EXCELON - SANDY BEACH
SHADEBOX LINES - DARK 12" x 24"
NOBLE METALLIC CERAMIC - SHADOW
AMERICAN WALNUT - 0555
WALL TILE FOR RESTROOMS
HANDRAILS AND CORNER GUARDS
CORNER GUARD
INPRO 800 HANDRAIL - SILVER - 0105HANDRAIL
INPRO 150 SURFACE MOUNT - SILVER - 0105
EP-1 EPOXY FLOOR SIKAFLOOR CUSTOM COLOR
PATH PTH264 STREAM
5 1/2" HEIGHT
ACCENT COLOR
DOOR FRAMES
ACCENT COLOR
PAINTPT-4 SHERWIN WILLIAMS SW 7072 ONLINE ACCENT COLOR
ARMSTRONG STANDARD EXCELON - SANDY BEACH
REFER SPECIFICATIONS
MILLWORK / DOORS
WT-4 WAINSCOT INPRO - PALLADIUM SHEET WHITE SAND - 0103 RE: INTERIORS
PANELS & 4" MOULDINGS TYPICAL
INPRO 2500 CHAIR RAIL - SILVER - 0105CRASH RAIL / TRIM 2" HEIGHT
3" WINGS TYPICAL
TILE - CONCRETETILE - LVT / VCT
CONCRETE
SLAB
DOOR
CENTERLINE OF
DOOR / TRANSITION STRIP
VINYL
FLOORING
DOOR
DOOR STOP
ADA COMPLIANT
RUBBER TRANSITION
STRIP
DOOR STOP / FRAME
AUTO DOOR BTM.
WHERE SPECIFIED
THIN SET TILE
THIN SET
TILE
PROVIDE SMOOTH TRANSITION
MILL FINISH ALUMINUM
TRANSITION STRIP -
CENTERLINE OF
DOOR / TRANSITION
DE
NOTE:
ALL TRANSITIONS TO COMPLY WITH
ADA/ANSI REQUIREMENTS AND BE THE FULL
LENGTH AND/OR WIDTH OF ANY OPENING
LVT / VCT - CARPETCONC - CARPET
TILE - CARPET
CENTERLINE OF DOOR /
TRANSITION STRIP
CENTERLINE OF DOOR
/ TRANSITION STRIP
DOOR STOP / FRAME
ADA COMPLIANT
RUBBER TRANSITION
STRIP
DOOR STOP / FRAME
DOOR
SEALED CONCRETE
FLOORING
DOOR
THIN SET TILE
TOP TO BE FLUSH
WITH ADJACENT
FLOORING CONCRETE SLAB
MILL FINISH ALUMINUM
TRANSITION STRIP -
CENTERLINE OF DOOR /
TRANSITION STRIP
DOOR STOP / FRAME
DOOR
CARPET TILES
AUTO DOOR BTM.
WHERE SPECIFIED
CONCRETE
SLAB
CARPET
TILES
CONCRETE SLAB
CARPET TILES
ADA COMPLIANT
RUBBER TRANSITION
STRIP
VCT
A
BC
MILL FINISH ALUMINUM
TRANSITION STRIP - PROVIDE
SMOOTH TRANSITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
Wichita, KS
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSULTANT
B
IM
/1
-V A
W
IC
H
IT
A /V
A
W ic h it a
C e n tr a l.
rv t
/2
/2
:5
:1
P
M
IN501
ROOM FINISH SCHEDULE /
TRANSITION DETAILSPrime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
589A7-19-401
Building 1
Conrad Pierce General Engineer/COR
2020.05.15 BJM JRC
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME
ROOM
CODE BASE FLOOR
WALL FINISHES CEILING SOUND
PROTECTION COMMENTSNORTH SOUTH EAST WEST MATL HT
125-1 ACCESSIBLE
VESTIBULE
- RB EP-1 GWB-PT-4 GWB-PT-4 GWB-PT-4 PT-4 GWB 8'-2" 1
126-1 VESTIBULE - RB EP-1 GLASS GLASS GLASS GLASS GWB 10'-2" 1
127-1 CORRIDOR - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 AT 8'-0" 1
128-1 WOMEN'S TLTF1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2
12", WT-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2 12",
WT-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12",W-1 WAINSCOT 24"
AT 8'-0" STC 40 3
129-1 MAS WAITING WRC01 RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0"
129A-1 TELECOM - RB SL CONC GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 AT 8'-0" 1
130-1 INTERVIEW - RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1
131-1 IT CLOSET - RB SL CONC GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 AT 8'-0" 1
132-1 INTERVIEW - RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1
133-1 MAS WORK AREA - RB CP-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 GWB-PT-1 AT 8'-0"
134-1 RELEASE OF INFO - RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 AT 8'-0" 1
135-1 MAS CHIEF OFA09 RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1
136-1 DEPT CHIEF OFA09 RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1
138-1 SHARED LOUNGE SL001 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0" 1
139-1 WAITING RB RSF-1,
RSF-2
GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 AT 8'-0" 1
140-1 SEC WORK SEC01 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
141-1 CORRIDOR RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
142-1 EXAM ROOM EXRG3 RB VCT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB LAY-IN PANELS 8'-0" STC 40 1
143-1 EXAM / TELE MED RB VCT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB LAY-IN PANELS 8'-0" STC 40 1
160-1 PROCEDURE ROOM EXRG6 RB WSF-1 GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0" 1
160A-1 CHEMO TOILET TLTU1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2 12",
WT-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12",W-1 WAINSCOT 24"
AT 8'-0" STC 40 3
161-1 HAC - RB SL CONC GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"
162-1 STORAGE - RB VCT-1 GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"
162A-1 ELECTRICAL - RB SL CONC GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"
164-1 INFUSION BAY - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 AT 8'-0" 2
165-1 NURSE STATION NSTA4 RB RSF-1 GWB-PT-3 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
166-1 INFUSION BAY - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
167-1 EXAM ROOM EXRG3 RB VCT-1 GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 GWB LAY-IN PANELS 8'-0" STC 40 1
168-1 CORRIDOR - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
168A-1 CORRIDOR - RB RSF-1,
RSF-2
GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
168B-1 CORRIDOR - - - - - - - -
169-1 CHEMO TOILET TLTU1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2 12",
WT-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12",W-1 WAINSCOT 24"
AT 8'-0"
170-1 SOILED STORAGE USCL1 CT-1 CT-1 GWB-PT-4 WT-1 WAINSCOT 60" & WT-2 12",
GWB-PT-4
GWB-PT-4 GWB-PT-4 AT 8'-0" 1
171-1 NOUR - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-3 AT 8'-0"
172-1 MEDS MEDP1 RB VCT-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
173-1 EYE WASH - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
174-1 CLEAN LINEN
STORAGE
UCCL1 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
175-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 AT 8'-0"
176-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 GWB-SC-PT-2 AT 8'-0" 2
177-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-3 GWB-SC-PT-3 GWB-SC-PT-2 AT 8'-0" 2
178-1 NURSE STATION NSTA4 RB RSF-1 GWB-PT-2 GWB-PT-3 GWB-PT-2 GWB-PT-2 AT 8'-0"
179-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-3 GWB-SC-PT-2 AT 8'-0" 2
180-1 CHEMO TOILET TLTU1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2 12",
WT-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12", W-1 WAINSCOT 24"
WT-1 WAINSCOT 60" & WT-2
12",W-1 WAINSCOT 24"
AT 8'-0" STC 40 3
181-1 STERILE STOR - RB SL CONC GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"
182-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 AT 8'-0" 2
183-1 CORRIDOR - RB RSF-1,
RSF-2
GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
184-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 AT 8'-0" 2
185-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 AT 8'-0" 2
186-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 AT 8'-0" 2
187-1 CRASH CART RCA01 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
188-1 PAT WEIGH-IN EXRG4 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"
CORR-1 CORR. - EXISTING BASE EP-1 WT-3 WAINSCOT +48",
GWB-PT-1
WT-3 WAINSCOT +48", GWB-PT-1 WT-3 WAINSCOT +48",
GWB-PT-1
WT-3 WAINSCOT +48",
GWB-PT-1
EL LOB-1 ELEVATOR LOBBY - EXISTING BASE EP-1 WT-3 WAINSCOT +48",
GWB-PT-1
WT-3 WAINSCOT +48", GWB-PT-1 WT-3 WAINSCOT +48",
GWB-PT-1
WT-3 WAINSCOT +48",
GWB-PT-1
LOBBY-1 LOBBY - EXISTING BASE EP-1 PT-1 PT-1 PT-1 PT-1 1
STAIR-E-1 STAIR - - -
STAIR-SE-1 STAIR - - -
NOTE: REFERENCE SHEET A-001 FOR ABBREVIATIONS
3" = 1'-0"1
TRANSITION DETAILS
COMMENTS:
1. WINDOWS TO RECEIVE BLINDS UNLESS NOTED OTHERWISE, IF APPLICABLE. REFER SPECIFICATIONS.
2. PROVIDE ROLLER SHADES, REFER SPECIFICATIONS.
3. PROVIDE OBSCURE GLASS, REFER SPECIFICATIONS.
4. ALL WALL BASE TO BE RUBBER BASE (RB) UNLESS NOTED OTHERWISE. REFER SECHDULES AND INTERIOR
ELEVATIONS.
FIRE PROTECTION GENERAL NOTES
FIRE PROTECTION ABBREVIATIONS
FIRE PROTECTION SYMBOL LEGEND
DESCRIPTIONLINETYPE
FIRE PROTECTION PIPING LINETYPES
FIRE PROTECTION GENERAL NOTES
NEW - BELOW GRADE
SCHEDULE
SPECIFICATIONS
TEMPERATURE
TYPICAL
WITH
MECHANICAL
MINIMUM
FOOT (FEET)
PC
MC MECHANICAL CONTRACTOR
PLUMBINGPLBG
PLUMBING CONTRACTOR
GPM
GAL
GALLONS PER MINUTE
GALLON
GENERAL CONTRACTOR
QTY QUANTITY
TEMP
TYP
SPEC
GC
MECH
MIN
W/
FT
SCH
STAINLESS STEELSS
NOT TO SCALENTS
1. CONTRACTOR SHALL PROVIDE DESIGN FOR SPRINKLER SYSTEMS FOR NEW REMODELED AREA. REFER TO ARCHITECTURAL DRAWINGS
FOR CEILING TYPES, HEIGHTS AND ROOM CLASSIFICATIONS.
2. MODIFY WET SYSTEM SERVING FIRST FLOOR REMODELED AREA.
3. COORDINATE INSTALLATION OF SPRINKLER PIPING AND ALL COMPONENTS WITH OTHER TRADES, OWNER, AND GENERAL CONTRACTOR.
4. FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13, CURRENT EDITION OF THE VA FIRE PROTECTION DESIGN GUIDE. INSURANCE
CARRIER AND ALL APPLICABLE STATE AND LOCAL CODES.
5. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT AND
STRUCTURAL ENGINEER.
6. PROVIDE MINIMUM 10 PSI SAFETY FACTOR.
7. WORKING DRAWINGS INDICATING SPRINKLER HEAD LOCATIONS AND EXPOSED AND CONCEALED PIPING ROUTING SHALL BE PROVIDED TO
THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION FOR APPROVAL.
8. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR ORGANIZING A COORDINATION MEETING WITH OTHER TRADES AND OWNER PRIOR
TO INSTALLATION.
9. SYSTEM PIPING LOCATION: WET SYSTEM PIPING SHALL BE INSTALLED AT HIGHEST ELEVATION POSSIBLE. PIPING SHALL BE INSTALLED
ABOVE ALL MECHANICAL EQUIPMENT, DUCTWORK, AND ALL PLUMBING SYSTEM PIPING. PROVIDE ADEQUATE CLEARANCE TO MECHANICAL
UNITS. FIRE PROTECTION CONTRACTOR SHALL COORDINATE FIRE PROTECTION PIPING PRIOR TO INSTALLATION.
10. PROPERLY TORQUE MECHANICAL TEES TO MANUFACTURER'S RECOMMENDATIONS.
11. FIRE PROTECTION PLANS ARE FOR REFERENCE ONLY. OCCUPANCIES AND AREAS OF PROTECTION NOTED ON THE PLANS SHALL BE
CONFIRMED WITH NFPA 13 AND AUTHORITIES HAVING JURISDICTION. THIS CONTRACTOR SHALL COMPLY WITH ANY CODE REQUIREMENTS
AS REQUIRED.
12. FIRE SEAL ALL PENETRATIONS THRU RATED STRUCTURES TO MAINTAIN FIRE RATING.
13. PROVIDE GUARDS FOR FULLY EXPOSED UPRIGHT SPRINKLER HEADS WITH BRASS FINISH.
14. SPRINKLER HEADS SEMI-RECESSED IN LAY-IN AND HARD CEILINGS SHALL HAVE WHITE FINISH.
FLOOR
FLOOR DRAIN
ADDITIONAL
ALTERNATE
COLUMN
DOWN
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
ELECTRICAL CONTRACTOR
CW COLD WATER
ADDL
ADD ADDENDUM
ADJ ADJUSTABLE
AFG
AFF
ALT
COL
DN
EC
FD
FLR
BELOW GRADEBG
AG ABOVE GRADE
CAST IRONCI
FIRE PROTECTIONFP
FIRE DEPARTMENT CONNECTIONFDC
SHUTOFF VALVE
CHECK VALVE
END CAP
BELL
FIRE DEPARTMENT CONNECTION(FDC)
DOUBLE CHECK VALVE
NEW - ABOVE GRADE
NEW - BELOW GRADE
SCHEDULE
SPECIFICATIONS
TEMPERATURE
TYPICAL
WITH
MECHANICAL
MINIMUM
FOOT (FEET)
PC
MC MECHANICAL CONTRACTOR
PLUMBINGPLBG
PLUMBING CONTRACTOR
GPM
GAL
GALLONS PER MINUTE
GALLON
GENERAL CONTRACTOR
QTY QUANTITY
TEMP
TYP
SPEC
GC
MECH
MIN
W/
FT
SCH
STAINLESS STEELSS
NOT TO SCALENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
2020.05.15
Building 1
589A7-19-401
Conrad Pierce General Engineer/COR
Prime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
Wichita, KS
B
IM
/1
-V A
W
IC
H
IT
A /M
E P
-C E
N T
R A
L -R
.r v t
/2
/2
:5
:1
P
M
FA001
FIRE PROTECTION LEGEND &
DETAILS
Revisions: Date:
TCC KPP
DN
2 3 4 5 6 7 8 9 10 11 12 13
B
C
F
H
I
J
K
N
O
P
EXISTING 6" SPRINKLER PIPE UP
FROM BASEMENT TO UPPER FLOORS
EXISTING SPRINKLER RISER DRAIN
PIPE TO EXTERIORTO REMAIN
NEW ZONE CONTROL
VALVE FOR 1ST FLOOR
INSTALL SPRINKLER
SYSTEM INSPECTORS
TEST DRAIN LINE DN
ALONG WALL TO
EXTERIOR PIT DRAIN
REMODELED AREA - LIGHT HAZARD
EXISTING BUILDING
REMODELED AREA - LIGHT HAZARD
M
10 11 12 13
CHEMO TRTMT
184-1
CHEMO TRTMT
185-1
CHEMO TRTMT
182-1 STERILE STOR
181-1
CHEMO TOILET
180-1
CHEMO TRTMT
179-1
CHEMO TRTMT
177-1
CHEMO TRTMT
176-1
NURSE STATION
178-1
CORRIDOR
183-1
CHEMO TRTMT
175-1
CHEMO TRTMT
186-1
MEDS
172-1 NOUR
171-1
CLEAN LINEN STORAGE
174-1
EYE WASH
173-1
SOILED STORAGE
170-1
EXAM ROOM
167-1
INFUSION BAY
164-1
ELECTRICAL
162A-1
STORAGE
162-1
CORRIDOR
168-1
NURSE STATION
165-1
EXAM / TELE MED
143-1
EXAM ROOM
142-1
CORRIDOR
141-1
SEC WORK
140-1
INFUSION BAY
166-1
CHEMO TOILET
169-1
WAITING
139-1
SHARED LOUNGE
138-1
DEPT CHIEF
136-1
MAS CHIEF
135-1
INTERVIEW
132-1IT CLOSET
131-1
WOMEN'S
128-1
MAS WORK AREA
133-1
PROCEDURE ROOM
160-1
OUTLINE OF PROJECT AREA
OUTLINE OF PROJECT AREA
EXISTING SPRINKLER PIPING &
HEADS TO REMAIN IN LOBBY
REMODELED AREA - LIGHT HAZARD
OUTLINE OF PROJECT AREA
EXISTING SPRINKLER PIPING
& HEADS TO REMAIN IN
CORRIDOR
EXISTING 4" SPRINKLER PIPE UP
FROM BASEMENT TO UPPER FLOORS
REMODELED AREA - LIGHT HAZARD4
4 4
(TYP)
4 (TYP)
4 4 4
OUTLINE OF PROJECT AREA
LOBBY
LOBBY-1
VESTIBULE
126-1
ACCESSIBLE VESTIBULE
125-1
ELEVATOR LOBBY
EL LOB-1
CORR.
CORR-1
MAS WAITING
129-1
INTERVIEW
130-1
RELEASE OF INFO
134-1
HAC
161-1
CORRIDOR
168B-1
STAIR
STAIR-SE-1
CHEMO TOILET
160A-1
OUTLINE OF PROJECT AREA
OUTLINE OF PROJECT AREA
4 4
EXISTING MECHANICAL CHASE
EXISTING
SPRINKLER PIPING
CORRIDOR
127-1
EXISTING SPRINKLER
PIPING & HEADS TO
REMAIN IN CORRIDOR
INSTALL NEW SPRINKLER ZONE VALVE, FLOW ALARM SWITCH AND TAMPER SWITCH
TO SERVE REMODLED AREAS. ZONE VALVE SHALL BE BUTTERFLY TYPE WITH
TAMPER SWITCHES. GATE OR OS&Y VALVES ARE NOT ALLOWED. COORDINATE
WIRING WITH ELECTRICAL OR FIRE ALARM CONTRACTOR.
INSTALL NEW SPRINKLER SYSTEM INSPECTORS TEST DRAIN VALVE AND DRAIN LINE
THRU EXTERIOR WALL ABOVE GRADE. COORDINATE VALVE LOCATION WITH
OWNER AND GENERAL CONTRACTOR.
CONNECT NEW 2 1/2" SPRINKLER MAIN LINE TO EXISTING IN LINE EXPOSED IN
STAIRWELL. FIELD VERIFY SIZE AND LOCATION.
LIGHT HAZARD AREA - PROVIDE NEW SPRINKLER HEADS OR RELOCATE EXISTING
HEADS IN REMODELED SPACE. MODIFY EXISTING SPRINKLER MAINS AND BRANCH
PIPING FOR NEW LAYOUT.
ORDINARY HAZARD GROUP 1 AREA - PROVIDE NEW SPRINKLER HEADS IN
REMODELED SPACE. MODIFY EXISTING SPRINKLER MAINS AND BRANCH PIPING FOR
NEW LAYOUT.
ORDINARY HAZARD GROUP 2 AREA - PROVIDE NEW SPRINKLER HEADS IN
REMODELED SPACE. MODIFY EXISTING SPRINKLER MAINS AND BRANCH PIPING FOR
NEW LAYOUT.
KEYED NOTES
1. COORDINATE WORK WITH ALL TRADES ON SITE.
2. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK.
3. REFER TO GENERAL NOTES ON SHEET FA001.
4. COORDINATE WITH BUILDING OWNER AND FIRE MARSHAL FOR BUILDING FIRE
SUPPRESSION SYSTEM SHUT-DOWN FOR CONNECTING TO AND/OR MODIFYING EXISTING
SYSTEM.
GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
2020.05.15
Building 1
589A7-19-401
Conrad Pierce General Engineer/COR
Prime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
Wichita, KS
B
IM
/1
-V A
W
IC
H
IT
A /M
E P
-C E
N T
R A
L -R
.r v t
/2
/2
:5
:1
P
M
FA101
FIRE PROTECTION PLAN FIRST
FLOOR
1/8" = 1'-0"
FIRE PROTECTION PLAN - FIRST FLOOR1
0 4' 8' 16'
1/8" = 1'-0"
Revisions: Date:
B
C
E F
H
I
J
K
N
O
P
10 11 12 13
EXISTING 4" SPRINKLER RISER TO REMAIN
2 1/2"
EXISTING EXPOSED SPRINKLER
PIPE & HEADS IN CORRIDOR &
LOBBY TO REMAIN, FIELD VERIFY
REMOVE ZONE VALVE, FLOW SWITCH
& TAMPER SWITCH FOR INSTALLING
NEW VALVES & SWITCHES
EXISTING EXPOSED SPRINKLER
PIPING & HEADS TO REMAIN
EXISTING 6" SPRINKLER
RISER TO REMAIN
REMOVE ZONE VALVE, TAMPER
SWITCH & FLOW SWITCH FOR
INSTALLING NEW VALVES
2 1/2"
REMOVE FIRE HOSE CABINET
& PIPE CONNECTION
REMOVE 2" SPRINKLER PIPE BACK TO MAIN
REMOVE AND/OR
RELOCATE MAIN
SPRINKLER PIPE FOR
NEW SPACE LAYOUT
REMOVE SPRINKLER SYSTEM
INSPECTORS TEST DRAIN
VALVE, PIPING & EXTERIOR
PIPING
REMOVE AND/OR RELOCATE
MAIN SPRINKLER PIPE FOR
NEW SPACE LAYOUT
REMOVE AND/OR RELOCATE
MAIN SPRINKLER PIPE FOR
NEW SPACE LAYOUT
REMOVE AND/OR
RELOCATE MAIN
SPRINKLER PIPE FOR
NEW SPACE LAYOUT
COORDIANTE WITH GC FOR WALL REPAIR
AFTER REMOVAL OF DRAIN PIPING
REMOVE AND/OR RELOCATE
SPRINKLER HEADS & BRANCH PIPING
FOR NEW SPACE LAYOUT
REMOVE AND/OR RELOCATE
SPRINKLER HEADS & BRANCH PIPING
FOR NEW SPACE LAYOUT
REMOVE AND/OR RELOCATE
SPRINKLER HEADS & BRANCH PIPING
FOR NEW SPACE LAYOUT
REMOVE AND/OR RELOCATE
SPRINKLER HEADS & BRANCH PIPING
FOR NEW SPACE LAYOUT
OUTLINE OF PROJECT AREA
OUTLINE OF PROJECT AREA
OUTLINE OF PROJECT AREA
1. COORDINATE WORK WITH ALL TRADES ON SITE.
2. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK.
3. REFER TO GENERAL NOTES ON SHEET FA001.
4. COORDINATE WITH BUILDING OWNER AND FIRE MARSHAL FOR BUILDING FIRE
SUPPRESSION SYSTEM SHUT-DOWN FOR CONNECTING TO AND/OR MODIFYING EXISTING
SYSTEM.
GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Robert J. Dole VA
Medical Center &
Regional Office Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE FOR RELOCATION OF
ONCOLOGY, HEMATOLOGY, AND
DIALYSIS 1ST FLOOR
WICHITA, KS
2020.05.15
Building 1
589A7-19-401
Conrad Pierce General Engineer/COR
Prime Architects
212 N Crawford Ave
Norman, OK 73069
866.226.8071
Gene Lavastida, Owner
Wichita, KS
B
IM
/1
-V A
W
IC
H
IT
A /M
E P
-C E
N T
R A
L -R
.r v t
/2
/2
:5
:2
P
M
FD101
FIRE PROTECTION - DEMOLITION -
FIRST FLOOR
1/8" = 1'-0"
FIRE PROTECTION PLAN - DEMOLITION -FIRST FLOOR1
0 4' 8' 16'
1/8" = 1'-0"
Revisions: Date:
G
DESCRIPTIONLINETYPE
PLUMBING PIPING LINETYPES
DEMOLITION
RECIRC WATER BELOW GRADE
RECIRC WATER
HOT WATER BELOW GRADE
HOT WATER
COLD WATER BELOW GRADE
COLD WATER
VENT BELOW GRADE
VENT ABOVE GRADE
STORM BELOW GRADE
STORM ABOVE GRADE
SANITARY BELOW GRADE
SANITARY ABOVE GRADE
GAS
GENERAL PLUMBING NOTES
PLUMBING ABBREVIATIONS
PLUMBING RENOVATION NOTES
MEDICAL GAS AREA ALARM SCHEDULE
MEDICAL GAS ZONE VALVE BOX SCHEDULE
MED GAS WALL OUTLET SCHEDULE
PLUMBING PIPING LEGEND
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE MANUFACTURER MODEL MOUNT
ROUGH-IN SCHEDULE
FITTINGS AND REMARKSCOLD HOT WASTE VENT
L-1
LAVATORY
(RESTROOMS)
AMERICAN
STANDARD
0355.012 WALL 1/2" 1/2" 1 1/2" 1 1/2"
SINGLE BOWL, COLOR WHITE, 4" CENTER HOLES, FRONT OVERFLOW HOLE. PROVIDE
CHICAGO FAUCETS MODEL 895-317GN2AE36ABCP GOOSENECK FAUCET (1.5 GPM) .
MCGUIRE HD155WC OFFSET GRID STRAINER, 8902C P-TRAP & LFBV2165
QUARTER-TURN SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL SUPPLY LINES.
TRUEBRO LAV GUARD2 #103 E-Z PIPE COVERS. INSTALL THERMOSTATIC MIXING VALVE
TMV-1 BELOW FIXTURE. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.
L-2
LAVATORY
(WOMENS RESTROOM)
AMERICAN
STANDARD
0476.028 COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"
SINGLE BOWL, COLOR WHITE, 4" CENTER HOLES, FRONT OVERFLOW HOLE. PROVIDE
CHICAGO FAUCETS MODEL 895-317GN2AE36ABCP GOOSENECK FAUCET (1.5 GPM).
MCGUIRE HD155WC OFFSET GRID STRAINER, 8902C P-TRAP & LFBV2165
QUARTER-TURN SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL SUPPLY LINES.
TRUEBRO LAV GUARD2 #103 E-Z PIPE COVERS. COORDINATE COUNTERTOP OPENINGS
WITH MILLWORK. INSTALL THERMOSTATIC MIXING VALVE TMV-1 BELOW COUNTERTOP.
L-3
LAVATORY
(SOILED STORAGE)
AMERICAN
STANDARD
0355.012 WALL 1/2" 1/2" 1 1/2" 1 1/2"
SINGLE BOWL, COLOR WHITE, 4" CENTER HOLES, FRONT OVERFLOW HOLE. PROVIDE
CHICAGO FAUCETS MODEL 116.203.AB.1 GOOSENECK FAUCET WITH BATTERY
OPERATED SENSOR (0.5 GPM) . MCGUIRE HD155WC OFFSET GRID STRAINER, 8902C
P-TRAP & LFBV2165 QUARTER-TURN SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL
SUPPLY LINES. TRUEBRO LAV GUARD2 #103 E-Z PIPE COVERS. INSTALL THERMOSTATIC
MIXING VALVE TMV-1 BELOW FIXTURE. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.
WC-1
WATER CLOSET
ADA
AMERICAN
STANDARD
3351.101 WALL 1 1/4" - 4" 2"
COLOR WHITE. PROVIDE SLOAN MODEL G2-8111-1.28 (1.28 GPF) BATTERY OPERATED
SENSOR FLUSH VALVE. PROVIDE BEMIS SEAT MODEL 1655SSCT, OPEN FRONT
ELONGATED SEAT, EXTERNAL CHECK HINGE, COLOR WHITE. PROVIDE ZURN NARROW
WALL CARRIER. ADA INSTALLATION. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.
WC-2 WATER CLOSET
AMERICAN
STANDARD
3351.101 WALL 1 1/4" - 4" 2"
COLOR WHITE. PROVIDE SLOAN MODEL G2-8111-1.28 (1.28 GPF) BATTERY OPERATED
SENSOR FLUSH VALVE. PROVIDE BEMIS SEAT MODEL 1655SSCT, OPEN FRONT
ELONGATED SEAT, EXTERNAL CHECK HINGE, COLOR WHITE. PROVIDE ZURN NARROW
WALL CARRIER. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.
S-1 EXAM ROOM SINK ELKAY PSLVR19172 COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"
SINGLE BOWL, STAINLESS STEEL, 6-1/8." DEPTH, OVERFLOW DRAIN OUTLET, 2 FAUCET
HOLES. PROVIDE ELKAY LK174 DRAIN STRAINER. PROVIDE CHICAGO FAUCETS MODEL
895-317GN2AE36ABCP GOOSENECK FAUCET. PROVIDE PALL MEDICAL QDTC DOCKING
STATION WITH QJ212A FILTER CAPSULE INSTALLED ON FAUCET SPOUT OUTLET.
PROVIDE MCGUIRE 8912 P-TRAP, LFBV2165 SERIES SUPPLY STOPS W/FLEXIBLE
STAINLESS STEEL SUPPLY LINES, INSTALL TMV-1 BELOW FIXTURE.
S-2
SINK
SHARED LOUNGE
ROOM 138-1
ELKAY LRAD1919653PD COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"
SINGLE BOWL, STAINLESS STEEL, 6.5" DEPTH, 3 FAUCET HOLES, S.S. DRAIN BASKET.
PROVIDE CHICAGO FAUCET MODEL 786-GN8AE36ABCP GOOSENECK FAUCET. PROVIDE
MCGUIRE 8912 P-TRAP, LFBV2165 SERIES SUPPLY STOPS W/FLEXIBLE STAINLESS
STEEL SUPPLY LINES, INSTALL TMV-1 BELOW FIXTURE. PROVIDE PALL MEDICAL QDTC
DOCKING STATION WITH QJ212A FILTER CAPSULE INSTALLED ON FAUCET SPOUT .
S-3
SINK
NOURISH AREA 171-1
ELKAY LRAD191965PD3 COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"
SINGLE BOWL, STAINLESS STEEL, 6.5" DEPTH, 3 FAUCET HOLES, S.S. DRAIN BASKET.
PROVIDE CHICAGO FAUCETS MODEL 786-GN8AE36ABCP GOOSENECK FAUCET.
PROVIDE PALL MEDICAL QDTC DOCKING STATION WITH QJ212A FILTER CAPSULE
INSTALLED ON FAUCET SPOUT OUTLET. PROVIDE MCGUIRE 8912 P-TRAP, LFBV2165
SERIES SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL SUPPLY LINES, INSTALL TMV-1
BELOW FIXTURE.
MS-1 MOP SINK FIAT
TSB-3000
24x24x12
FLOOR 1/2" 1/2" 3" 1 1/2"
PROVIDE FIAT 832AA HOSE & BRACKET, 889-CC MOP BRACKET, MSG 2424 SS WALL
GUARDS. CHICAGO FAUCET MODEL 897-CP, PROVIDE CHECK VALVES ON HOT & COLD
WATER BRANCH PIPING SERVING MOP SINK.
EW-1
SINK WITH EMERGENCY
EYEWASH STATION
ELKAY WCLWO19230SD3 WALL 1/2" 1/2" 1 1/2" 1 1/2"
STAINLESS STEEL WALL MOUNT SINK, 3 FAUCET HOLES, GRID STRAINER & OVERFLOW.
PROVIDE SPEAKMAN SEF-1800-CA-TW FAUCET WITH INTEGRAL EMERGENCY EYEWASH
& BELOW DECK THERMOSTATIC MIXING VALVE. COMPLIES WITH ANSI Z358.1. PROVIDE
MCGUIRE 8912C P-TRAP & LFBV2165CC SUPPLY STOPS. WATTS 6 CHECK STOPS.
TRUEBRO LAV GUARD2 E-Z PIPE COVERS. REFER TO ARCHITECT'S PLANS FOR RIM
HEIGHT. SEE EYEWASH/FAUCET DETAIL 8/P501.
CS-1 CLINICAL SINK
AMERICAN
STANDARD
9504.999.020 FLOOR 1 1/2" 3/4" 4" 2"
COLOR WHITE. PROVIDE AMERICAN STANDARD PEDESTAL BASE 71009-201.081, FRONT
& SIDE RIM GUARDS 7832504075. PROVIDE SLOAN ROYAL FLUSH VALVE 117, CHICAGO
FAUCETS 815-VBCP FAUCET WITH WATTS 8A-C VACUUM BREAKER & CHICAGO FAUCETS
FOOT PEDALS WITH SPRAY HOSE MODEL 910-G777-19KCP. SEE DETAIL 6/P501.
FD FLOOR DRAIN ZURN ZN415-6SZ-P-VP FLOOR - - 2" -
6" SQUARE NICKEL BRONZE STRAINER, CAST IRON BODY ANCHOR FLANGE, CLAMP
COLLAR, ADJUSTABLE COLLAR, ADJUSTABLE STRAINER HEIGHT, VANDAL-PROOF
SECURED TOP, 1/2" TRAP PRIMER CONNECTION.
FCO FLOOR CLEANOUT ZURN ZN1400-SZ-K-VP FLOOR - -
SEE
PLANS
ADJUSTABLE HEIGHT, CAST IRON BODY, ANCHOR FLANGE, SCORIATED SQUARE TOP
WITH NICKEL BRONZE FINISH, VANDAL RESISTANT COVER SCREWS.
WCO WALL CLEANOUT ZURN Z1445-VP WALL - -
SEE
PLANS
CAST IRON CLEANOUT TEE, THREADED BRASS PLUG, PROVIDE ZS1469-VP STAINLESS
STEEL ROUND ACCESS COVER WITH VANDAL RESISTANT SECURING SCREW .
HA-1 HAMMER ARRESTOR WATTS LF15M2 PIPE VARIES - - -
LEAD-FREE CONSTRUCTION, PDI WH201 LISTED, PRE-CHARGED, PERMANENT SEALED
AIR CHAMBER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
AP-1 ACCESS PANEL ACUDOR
UF-5000 14x14
CLSS
WALL - - - -
14"x14" STEEL, 16 GAGE DOOR & FRAME, 18 GAGE MOUNTING FRAME. CONCEALED
HINGE, CYLINDER LOCK & KEY, STAINLESS STEEL FINISH. CONCEALED FASTENING
POINTS.
TMV-1
THERMOSTATIC MIXING
VALVE
WATTS LFMMV-M1
BELOW
FIXTURE
1/2" 1/2" - -
LEAD FREE MIXING VALVE WITH ADJUSTABLE TEMPERATURE SET-POINT & LOCKABLE,
INTEGRAL CHECK STOPS & STRAINERS, 1/2" INLETS & OUTLET. SET OUTLET TEMP AT
105 DEGREES F. ASSE 1070 LISTED.
WB-1 WATER BOX SIOUX CHIEF 696RG1010PF WALL 1/2" - - -
FIRE-RATED RECESSED WALL ABS BOX WITH FACE PLATE, 1/2" QUARTER TURN BALL
VALVES WITH INTEGRAL WATER HAMMER ARRESTOR, 3/8" OUTLET.
LB-1
LAUNDRY BOX
(ICE/WATER MACHINE)
SIOUX CHIEF 696RG2313PF WALL 1/2" 1/2" 2" 1 1/2"
FIRE-RATED RECESSED WALL BOX, 1/2" QUARTER TURN BALL VALVES WITH INTEGRAL
WATER HAMMER ARRESTORS, 2" WASTE OUTLET. SERVES ICE/WATER MACHINE.
TBV-1
THERMOSTATIC
BALANCING VALVE
CALEFFI 116141AC PIPE - 1/2" - -
LOW LEAD BRASS BODY, ADJUSTABLE OUTLET TEMPERATURE RANGE WITH ADJUSTING
KNOB, CHECK VALVE, TEMPERATURE GAUGE, PROVIDE BALL VALVES ON BOTH SIDES
OF VALVE, COORDINATE HOT RETURN WATER TEMPERATURE WITH BUILDING OWNER.
RD
ROOF DRAIN WITH
OVERFLOW DRAIN
ZURN Z165 ROOF - - 3" -
8-3/8" DIAMETER ROOF DRAIN & OVERFLOW DRAIN COMBINATION, DURA-COATED CAST
IRON BODY, CAST IRON DOME, COMBINATION MEMBRANE FLASHING CLAMP/GRAVEL
GUARD, DECK MOUNTING PLATE. 2" HIGH WATER DAM ON OVERFLOW DRAIN.
DS DOWNSPOUT ZURN Z199 PIPE - - 3" - NICKEL BRONZE BODY, WALL FLANGE AND NOZZLE OUTLET.
TP-1
TRAP PRIMER
(ELECTRONIC)
PRECISION
PLUMBING
PRODUCTS
MPB-500- 115V PIPE 1/2" - - -
ENCLOSURE WITH CONTROL TIMER, SOLENOID VALVE, AIR GAP, 1/2" INLET, 1/2" OUTLET.
120V HARD WIRE CONNECTION. PIPE OUTLET TO HUB DRAIN. INSTALL PER
MANUFACTURERS RECOMMENDATIONS. UNIT SHALL MEET ASSE 1044 & BE U.L. LISTED.
COORDINATE POWER WITH EC.
CCP-1
COLD CIRCULATION PUMP
(BASEMENT)
BELL & GOSSETT NBF-18S PIPE 1/2" - - -
COLD WATER IN-LINE CIRCULATION PUMP, LEAD-FREE BRONZE BODY, WET ROTOR
TYPE, 1/25 HP,120 V. PROVIDE HONEYWELL TEMP CONTROLLER T775B2040 (120V) WITH
(2) WIRED REMOTE LOW VOLTAGE WATER TEMP SENSORS, WIRE PUMP TO
CONTROLLER, WIRE SOLENOID VALVE TO CONTROLLER. COORDINATE WIRING WITH
EC.
SV-1
SOLENOID VALVE
(COLD WATER DUMP)
HAC ROOM 161-1
ASCO RED HAT 8210G002 PIPE 1/2" - - -
COLD WATER VALVE, LEAD-FREE BRASS, LOW VOLTAGE, (NORMALLY CLOSED).
COORDINATE WIRING TO PUMP CONTROLLER WITH EC. PROVIDE 1/2" BALL VALVE ON
DISCHARGE OF SOLENOID VALVE. ASSEMBLY TO DRAIN DOWN DOMESTIC COLD WATER
MAIN WHEN TEMP REACHES 67 DEG F. COORDINATE VALVE OPERATION WITH OWNER.
1. THESE DRAWINGS SHALL NOT BE SCALED. SEE ARCHITECTURAL/CIVIL DRAWINGS FOR
DIMENSIONAL INFORMATION. THIS ENGINEER WILL NOT BE LIABLE FOR MISCALCULATED
PRODUCT TAKE-OFFS DUE TO SCALING OF DRAWINGS.
2. ALL SANITARY PIPING SHALL HAVE A 1/8" PER FOOT SLOPE UNLESS OTHERWISE NOTED. 2"
SANITARY OR SMALLER SHALL HAVE A 1/4" PER FOOT SLOPE.
3. FIELD VERIFY VENT PIPE MAINS IN CONSTRUCTION ZONE. CONNECT NEW BRANCH VENT PIPING
TO EXISTING VENT RISERS UP TO SECOND FLOOR.
4. VALVES AND FITTINGS SHALL BE OF SAME SIZE AS THE LINE ON WHICH THEY ARE LOCATED, UNLESS OTHERWISE INDICATED ON DRAWINGS.
5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES.
6. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND
CONNECTING ALL SANITARY AND WASTE PIPING AND NOTIFY ENGINEER OF ANY DISCREPANCIES.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING
INTEGRITY OF ALL PIPING AND PENETRATIONS.
8. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH
NO CHANGES IN SIZING.
9. CHANGES IN THE DIRECTION OF SANITARY DRAIN PIPING SHALL NOT BE MADE WITH FITTINGS
WHICH WILL CAUSE EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER
ADVERSE EFFECT UNLESS PHYSICALLY IMPOSSIBLE (I.E.: USE OF SANITARY TEE IN A HORIZONTAL
CONNECTION, USE OF A DOUBLE SANITARY TEE IN A VERTICAL STACK, IN GENERAL, USE OF
SHORT-RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK CONNECTION).
10. CONTRACTOR SHALL GIVE 48 HOURS HOUR EMERGENCY LOCATE NOTICE TO APPLICABLE UTILITY
COMPANY PRIOR TO PERFORMING WORK INVOLVING UTILITIES.
11. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL
SANITATION FOUNDATION.
12. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. PIPING EXPOSED
SHALL BE SLOPED AND PAINTED TO MATCH ARCHITECTURAL FINISHES. PIPING IN MECHANICAL
ROOMS MAY BE EXPOSED.
13. SITE UTILITY CONNECTIONS SHALL BE PROVIDED ON CIVIL DRAWINGS. ALL SERVICES SHOWN ON
THIS SET OF PLANS TERMINATE 5'-0" FROM BUILDING, UNLESS SHOWN OTHERWISE ON DRAWINGS.
PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SITE UTILITIES. (INC. CLEAN OUTS, INCREASES, BACKWATER VALVES, ETC.)
14. COORDINATE WITH ARCHITECT/GENERAL CONTRACTOR FOR INSTALLATION OF HOSE BIBS.
HEIGHT OF INSTALLATION SHALL BE DETERMINED IN FIELD.
15. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE
TO BE CONNECTED BEFORE INSTALLATION OF NEW SEWER LINE.
16. ALL VENTS THROUGH ROOF SHALL BE MIN. 10'-0" FROM ANY AIR INTAKES.
17. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS.
18. CONTRACTOR SHALL ROUGH-IN ALL WASTES AND SUPPLIES TO SPECIAL EQUIPMENT ACCORDING
TO MANUFACTURER'S SHOP DRAWINGS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE
VALVED. INSTALL VACUUM BREAKERS WHERE REQUIRED BY CODE.
19. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR
TO DROP FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY
NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND
LOCATION APPROVED BY STRUCTURAL ENGINEER. PROVIDE LINK-SEALS IN ALL PENETRATIONS
OF EXTERIOR WALLS.
20. ALL PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE IN PROVIDED CEILING SPACE.
21. COORDINATE PIPING INSTALLATION AS TO NOT INTERFERE WITH HVAC EQUIPMENT ACCESS.
22. ANY ERRORS OR AMBIGUITIES IN THE PLANS AND/OR SPECIFICATIONS THAT ARE DISCOVERED BY
THE CONTRACTOR SHALL BE REPORTED TO THE ARCHITECT/ENGINEER BEFORE WORK IS
STARTED. OMISSION OF PARTICULAR REFERENCE TO ANY ITEM NECESSARY FOR COMPLETE
INSTALLATION AND PROPER OPERATION THEREOF SHALL NOT RELIEVE THE CONTRACTOR OF THE
RESPONSIBILITY OF FURNISHING THE SAME AT NO EXTRA COST. THE CONTRACTOR IS
RESPONSIBLE FOR REVIEWING ALL CONSTRUCTION DOCUMENTS FOR INFORMATION PRIOR TO
BID.
23. VERIFY WITH ARCHITECT ON ALL EQUIPMENT AND FIXTURES REQUIRING PLUMBING PRIOR TO BID.
COORDINATE EXACT LOCATIONS AND CONNECTIONS.
24. ALL WORK SHALL BE IN COMPLIANCE WITH STATE AND LOCAL CODES INCLUDING INTERNATIONAL
PLUMBING CODE 2015 AND MEDICAL GAS CODE NFPA 99.
25. CONTRACTOR SHALL PAY ALL FEES, PERMITS, LICENSES, ETC. NECESSARY FOR PROPER
COMPLETION OF WORK.
26. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
27. PROVIDE TRAP PRIMER CONNECTION TO ALL FLOOR DRAINS, FLOOR SINKS AND OPEN SITES.
WHERE TRAP GUARDS ARE PROHIBITED, PROVIDE ELECTRONIC TRAP PRIMER VALVE W/MANIFOLD
FOR EVERY FOUR(4) FIXTURES OR EQUAL.
28. PROVIDE RIGID CONNECTION BETWEEN ALL SENSOR VALVES AND SENSOR LOCATION.
29. MOUNT ALL FIXTURE SENSORS PER MANUFACTURER'S RECOMMENDATIONS.
30. PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE SYSTEMS AT END OF RUNS, CHANGES
IN DIRECTION AND ELSEWHERE AS INDICATED ON THE DRAWINGS. IF A CONFLICT OCCURS
BETWEEN THE CONTRACT DRAWINGS AND THE SPECIFICATIONS, INDICATE THAT THE
SPECIFICATIONS OR MORE STRINGENT CONDITION SHALL GOVERN, UNLESS INSTRUCTED
OTHERWISE.
31. ACCURATE "AS-BUILT" DRAWINGS SHALL BE MAINTAINED DURING THE CONSTRUCTION.
SCHEDULE
SPECIFICATIONS
TEMPERATURE
TYPICAL
WITH
MECHANICAL
MINIMUM
EQUAL
FLOOR
FLOOR DRAIN
FOOT (FEET)
ADDITIONAL
ALTERNATE
COLUMN
DOWN
PC
MC MECHANICAL CONTRACTOR
PLUMBING
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
ELECTRICAL CONTRACTOR
F
PLBG
PLUMBING CONTRACTOR
CLEANOUT
FCO
VTR
HW
CO
CW COLD WATER
GPM
GAL
GALLONS PER MINUTE
GALLON
GENERAL CONTRACTOR
FURNACE
ADDL
ADD ADDENDUM
ADJ ADJUSTABLE
PRES PRESSURE
QTY QUANTITY
SAN SANITARY
TEMP
TYP
SPEC
HOT WATER
GC
MECH
MIN
W/
AFG
AFF
ALT
COL
DN
EC
EQ
FT
FD
FLR
SCH
FLOOR CLEANOUT
WCO WALL CLEANOUT
VENT THRU ROOF
STAINLESS STEELSS
NOT TO SCALENTS
BELOW GRADEBG
AG ABOVE GRADE
NON POTABLE COLD WATERNPCW
WC WATER CLOSET
NATURAL GASNG
RTU ROOFTOP UNIT
GW GREASE WASTE
HWR HOT WATER RETURN
V VENT
EXTERIOR CLEANOUTECO
1. WHERE EXISTING PIPING IS DESIGNATED TO BE REMOVED AND CAPPED, ALL PIPING
SERVING THE DESIGNATED FIXTURE SHALL BE REMOVED FROM WITHIN WALLS TO THE
POINT DESIGNATED ON THE DRAWINGS OR TO A CLEARLY VISIBLE POINT BELOW THE
FLOOR IN THE CRAWL SPACE OR ABOVE THE CEILING. PIPING SHALL BE CAPPED BY
APPROVED CAPPING METHODS UTILIZING PIPE CAPS INTENDED FOR SUCH USE. ALL
CAPS SHALL BE AIRTIGHT AND WATERTIGHT.
2. WHERE EXISTING SURFACES ARE DISRUPTED DUE TO THE REMOVAL OF EXISTING
EQUIPMENT OR PIPING, THIS CONTRACTOR SHALL BE RESPONSIBLE OR THE REPAIR OF
DISRUPTED SURFACES TO MATCH EXISTING ADJACENT SURFACES.
3. SANITARY VENTS NOT TO BE REUSED SHALL BE CAPPED ABOVE THE FIRST FLOOR
CEILING AND LEFT IN PLACE FOR POSSIBLE FUTURE USE.
4. PLUMBING FIXTURES DESIGNATED TO BE REUSED SHALL BE CLEANED AND
MAINTENANCE SERVICED TO OPERATE AS INTENDED.
5. EXISTING CONDITIONS AS SHOWN ON THE DRAWINGS ARE TAKEN FROM ORIGINAL
AND AS-BUILT DRAWINGS OF THE BUILDING AND IN PART ARE UNVERIFIED. FIELD
CONDITIONS SHALL GOVERN. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO
INITIATION OF WORK.
6. ALL EXISTING SANITARY, DOMESTIC WATER, MEDICAL GASES, RAINWATER, AND FIRE
PROTECTION PIPING SHALL BE RELOCATED TO CREATE REQUIRED SPACE FOR
INSTALLATION OF ALL NEW SERVICES FOR NEW CONSTRUCTION, INCLUDING BUT NOT
LIMITED TO H.V.A.C., ELECTRICAL, PLUMBING, AND FIRE PROTECTION TRADES.
CONTRACTOR SHALL INCLUDE ALL NEW PIPING AND FITTINGS REQUIRED AND
RELOCATE ANY AND ALL EXISTING SERVICES.
7. ALL EXISTING PIPING, NOT REMAINING IN SERVICE AFTER NEW CONSTRUCTION,
SHALL BE REMOVED.
8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EXISTING
PLUMBING FIXTURES AND TRIM, PIPING, VALVES, ETC. IN AREAS TO BE DEMOLISHED.
9. ALL EXISTING PLUMBING FIXTURES TO BE REMOVED AND ARE NOT TO BE REUSED
SHALL REMAIN THE PROPERTY OF THE OWNER. DISCARD UNWANTED FIXTURES AT AT
THE DISCRETION OF THE OWNER.
10. PIPING WHICH IS TO REMAIN IN SERVICE SHALL NOT BE DISTURBED. EXISTING PIPING
BROKEN DURING CONSTRUCTION SHALL BE REPLACED WITH NEW PIPING OF THE SAME
SIZE AND MATERIAL.
11. PLUMBING CONTRACTOR SHALL SUBMIT SHOP DRAWINGS APPROVED BY THE
AUTHORITIES HAVING JURISDICTION TO THE ARCHITECT/ENGINEER FOR ANY PIPING
CONFIGURATIONS AND SIZES THAT DIFFER FROM THOSE SHOWN ON PLUMBING
DRAWINGS AS A RESULT OF EXISTING SITE CONDITIONS AND/OR EXISTING PIPING
LOCATIONS.
12. EXISTING BUILDING SEWERS THAT ARE USED WITH NEW BUILDING SANITARY
SEWERS SHALL BE EXAMINED AND TESTED TO CONFORM IN ALL RESPECTS TO ALL
REQUIREMENTS OF PLUMBING AUTHORITY HAVING JURISDICTION AND APPLICABLE
PLUMBING CODES.
13. ALL EXISTING MEDICAL GAS OUTLETS REMOVED SHALL BE TURNED OVER TO THE
OWNER. ALL OUTLETS SHALL BE REMOVED FROM THE WALL AND ALL PIPING SERVING
THE OUTLETS REMOVED TO ABOVE THE CEILING AND CAPPED.
14. ALL EXISTING SANITARY, DOMESTIC WATER, AND RAINWATER PIPING THAT ARE
LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND REMAINING IN SERVICE AFTER
CONSTRUCTION SHALL BE RELOCATED TO NEW WALLS, CHASES, ETC.
15. COORDINATE WITH GENERAL CONTRACTOR TO PATCH ALL EXISTING WALLS,
FLOORS, CEILINGS, ETC., AS REQUIRED BY NEW WORK. SEE SPECIFICATIONS.
16. PROVIDE GUIDELINES FOR CUTTING AND NOTCHING STRUCTURAL MEMBERS FOR
PIPE PENETRATIONS. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER
TRADES PRIOR TO FABRICATION, PURCHASE AND/OR INSTALLATION OF THE WORK. NO
PLUMBING PIPING (DOMESTIC COLD, HOT AND RETURN WATER, SANITARY, STORM,
ETC.) SHALL BE RUN OVER ELECTRICAL, LOW VOLTAGE, TELECOMMUNICATION OR
COMPUTER ROOMS.
17. COORDINATE WITH MECHANICAL CONTRACTOR FOR REQUIRED CONDENSATE DRAIN
LINE DISCONNECTION, MODIFICATIONS AND RECONNECTION AS NECESSARY.
NOTESMODEL NUMBERMANUFACTURERDESCRIPTIONTYPE MED AIRMED VACO2
AA-1 ALLXXXALARM PANEL
NOTESMODEL NUMBERMANUFACTURERDESCRIPTIONTYPE MED AIRMED VACO2
1,2BOX ASSEMBLY
THREE VALVE ZONE
ZB-1 1/2"1 1/4"3/4"
NOTE:
1. PROVIDE BEACON MEDAES REMOTE TRANSDUCERS AS INDICATED IN PLAN. LOCATE IN ZONE VALVE BOX WHERE INDICATED ON PLANS.
2. PRIOR TO INSTALLATION FIELD VERIFY FINAL LOCATION OF ALARM WITH ARCHITECT AND GENERAL CONTRACTOR REP.
3. LOW VOLTAGE WIRING FROM REMOTE TRANSDUCERS TO AREA ALARM BY PC.
NOTE:
1. PRIOR TO INSTALLATION FIELD VERIFY FINAL LOCATION OF VALVE WITH ARCHITECT AND GENERAL CONTRACTOR.
2. PROVIDE REMOTE TRANSDUCERS IN ZONE VALVE BOX AS INDICATED ON PLANS.
BEACON MEDAES
BEACON MEDAES
NOTES
ALL
TYPE MANUFACTURER
OXYGEN
CATALOG NUMBER
#121040-00BEACON MEDAES
ALLMED VAC #151043-00BEACON MEDAES
ALLMED AIR #151042-00BEACON MEDAES
#M3-A10-OAV
#ZVB3-ABD-ENG
MA MEDICAL AIR
MEDICAL VACUUMMV
OXYGENO2
RD ROOF DRAIN
DOWNSPOUTDS
STORM DRAINSD
OVERFLOW ROOF DRAINORD
OVERFLOW STORM DRAINOSD
CIRCUIT SETTER
BALL VALVE OR SHUT-OFF VALVE
SPRING…
This is the start of the file's text. The full file is on GovTribe.