ATTACHMENT 3 - Drawings 2 of 2.pdf

PDF 23 MB Posted

Attached to
Z2DA--Renovate Oncology Hematology, for 1st Floor Bldg. 1 - Wichita
Solicitation number
36E77620B0005
Issued by

About this file

This notice provides information about an upcoming federal contract opportunity for renovation and relocation services at the Robert J. Dole VA Medical Center in Wichita, Kansas. The Department of Veterans Affairs intends to solicit proposals for a firm-fixed-price design-build contract valued between $2-5 million to renovate the first floor for oncology, hematology, and dialysis services. The work includes general construction, site work, and removal of existing structures. The solicitation will be issued as an Invitation for Bid and evaluated based on lowest price from SDVOSB concerns. The performance period is approximately 270 days from notice to proceed. Questions must be submitted in writing by mid-June 2020.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A5077 A5078

CORNER GUARDS

HANDRAIL / WALLGUARD

CORNER GUARDS

HANDRAIL / WALLGUARD

RB

A5077

(OPEN)

1' - 0"

E0954

M4020 X9910 X9910

F3053

M1620 M1620 A5077A5077

CORNER GUARDS

HANDRAIL / WALLGUARD

CORNER GUARDS

HANDRAIL / WALLGUARD

CORNER GUARDS

GYP BD COLUMN

FURROUT

F3051

3"

F3052

3"

2' - 10 1/2" 2' - 10 1/2" 2' - 0"

7' - 9"

F3200

CORNER

GUARDS

IN

PT-3

E0954

FURR-DN

EQ EQ

" A5107

A5107 A5107

1' - 0 1/2"3' - 0"3' - 4"4' - 0"

A1015

A1015

C0046 C06M0 C06M0 C0045

CORNER

GUARDS

D9280

IN

IN

IN

1/4" TEMPERED

GLASS

LAY-IN CEILING

M4267

A1107M0505 M0765

A5077

A5078

A51454"2" 1

CD021

A5105

A5107

A5075

A5080

A5107

P3101

IN

IN

FURR-DN

EXIST WINDOW

BEYOND

CURTIAN

TRACK

F3200

PT-3 PT-3

FURR-DN

A1107

M0765

M0505

A5145

A5105

CD021

IN

F3200

M0755 M0750M4267

M1405

FURR-DN

A5180

M4116

M4267 M4267

M4116

PT-3

PT-3

A5105

A5107

CD021

M0505M0765A1107

A5145

IN

F3200

FURR-DN

A5105

CD021

IN

A5108

" A5107

A5107 A5107

EQEQ

FURR-DN

(OPEN)

A5078 A5077

A5145

M0505

M0765 A1107

F3200

M0755M0750

A5108

CORNER

GAURD

A1066 A5075

P3100

P9050

ADA GRAB

BARS

A5107

WT-2

WT-1

A5180

CD021A1107 M0755

M0505 A5107 A5105

IN

F3200

M0765

M0750

M4267

FURR-DN

A5078 A5077 A5077

A5078

A5180 A5180

A5077

A5078

A5080 A5075

P3101

A5077

A5078

M1620 A5077 A5077

A5078

IN

CHEMO TREAT. CHEMO TREAT.

INFUSION BAY

FURR-DN

M3110

HANDRAIL /

WALLGUARD

2' - 3 3/8" 3' - 0"

IN

IN

CORNER GAURD

GUARD/HANDRAIL

BUMPER GUARD

REF 12/IN210

A5180

2' - 1" 2' - 6" 2' - 6"

2' - 6" 1' - 5" 2' - 1" 2' - 6" 2' - 6"

A5180 A5180

A5080 A5075

CS150

R4100

F2015

A5077

A5078

IN

1/4" TEMPERED

GLASS

1/4" TEMPERED

GLASS

COLUMN FURG

COLUMN

FURG

(NURSE

STATION)

(INFUSION

BAY) (CHEMO

TREATMENT)

(NURSE

STATION)

FURR-DN

HANDRAIL /

WALLGUARD

CORNER

GUARDS TYP.

K4665

K1552

R6200 C03F0 C03G0C03F0 3

A5080A6046 FURR-DN

M1801

M1802

A5107

A5080

A5075

3' - 0"

IN

FURR DN

PT-3

A5180

M1802

M1801

A1014 A5146

"5

M4200

M1802

A1132

F3200

A5078

EQ EQ EQ EQ

IN

PT-3

FURR-DN

11' - 5 1/4"

11 3/4"

3' - 0" 3' - 4 3/4" 4' - 0"

A1015

A1015

F3200 C06M0

C0046C0045

D9280

IN

IN

IN

EQ EQ EQ

REFERENCE AE213

FOR MILLWORK

SECTIONS

REFERENCE IN102 FOR

COUNTERTOP AND

BACKSPLASH FINISHES

GUARDRAIL

5/8" GYP. BD. ON 3 5/8"

METAL STUDS

RUBBER BASE

REF. FINISH SCHED.

FLOORING

REF. FINISH SCHED.

LAY-IN CEILING TILES

AND GRID SYSTEM

LAY-IN CEILING

GYP. BD. WALL AND

COLUMN BEYOND

RECESSED ALUMINUM TRACK

ATTACHED TO METAL STUD

TRACK TO RECIEVE GLASS

RECESSED ALUMINUM TRACK

ATTACHED TO METAL HEADER

STUD TRACK TO RECIEVE GLASS

A5107 A5107 A5107 C06M0

A1066 A5180

E0945

A5107

A1014

M4200

A5078 M1801

E0945

A1107

A5146 M0755 M0765

M0750

A5145

CG

F3200

PT-3

CG

A5080

A5075

A5180

3' - 0"

IN

FURR-DN

A5105

A5090

A1017

A5200

A5080

P9050

ADA GRAB

BARS

CG

A1066

P3100

WT-1

WT-2

A5145

CG

A5107

A1017

A5200

A5090

ADA GRAB

BARS

CG

A5080

A5075

EXIST. WINDOWS

RETURN TILE TO WINDOWS

ADA GRAB

BARS

INTERIOR ELEVATION NOTES

1. REF: FOR TYPICAL TOILET WALL ELEVATIONS.

2. REF: MEP DRAWINGS FOR SPECIFIC ELEC. INFORMATION.

3. CORNER GUARDS TYPICAL, REFER SPECIFICATIONS.

4. REF: AE / 401 FOR EQUIPMENT SCHEDULE

5. ALL CABINETS L1 UNLESS NOTED OTHERWISE.

6. ALL COUNTERTOPS SS1 UNLESS NOTED OTHERWISE.

7. ALL WALL PT-2 FIELD COLOR UNLESS NOTED OTHERWISE.

8. MILLWORK CONTRACTING SUB TO VERIFY ALL SPACES

BEFORE SUBMITTING SHOP DRAWINGS.

/28 IN203

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

Wichita, KS

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSULTANT

B

IM

/1

-V A

W

IC

H

IT

A /V

A

W ic h it a

C e n tr a l.

rv t

/2

/2

:5

:5

P

M

IN202

INTERIOR ELEVATIONS

Prime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

589A7-19-401

Building 1

Conrad Pierce General Engineer/COR

2020.05.15 BJM JRC

0 2' 4' 8'

1/4" = 1'-0" 1/4" = 1'-0"1

CORRIDOR 141 EAST

1/4" = 1'-0"2

CORRIDOR 141 WEST

1/4" = 1'-0"3 NURSE STATION 178-a

1/4" = 1'-0"4 NURSE STATION 178-b

1/4" = 1'-0"5

CHEMO TRTMT 186 SOUTH

1/4" = 1'-0"6

CHEMO TRTMT 186 WEST

1/4" = 1'-0"7

CHEMO TRTMT 185 EAST

1/4" = 1'-0"8

CHEMO TRTMT 182 NORTH

1/4" = 1'-0"9

CHEMO TRTMT 182 EAST

1/4" = 1'-0"10

CHEMO TRTMT 182 SOUTH

1/4" = 1'-0"11

CHEMO TRTMT 182 WEST

1/4" = 1'-0"12

CHEMO TLT 180 NORTH

1/4" = 1'-0"14

CHEMO TLT 180 SOUTH

1/4" = 1'-0"15

CHEMO TRTMT 177 SOUTH

1/4" = 1'-0"16

CORRIDOR 168 EAST

1/4" = 1'-0"17

CORRIDOR 168 WEST

1/4" = 1'-0"18

EXAM 167 NORTH

1/4" = 1'-0"19

EXAM 167 EAST

1/4" = 1'-0"20

EXAM 167 SOUTH

1/4" = 1'-0"21

EXAM 167 WEST

1/4" = 1'-0"22

NURSE STATION 165 NORTH

1/4" = 1'-0"23

NURSE STATION 165 SOUTH

1/4" = 1'-0"24

PROC RM 160 NORTH

1/4" = 1'-0"25

PROC RM 160 EAST

1/4" = 1'-0"26

PROC RM 160 SOUTH

1/4" = 1'-0"27

PROC RM 160 WEST

1/4" = 1'-0"13

CHEMO TLT 180 EAST

1/4" = 1'-0"28

CHEMO TLT 160A NORTH

1/4" = 1'-0"29

CHEMO TLT 160A EAST

1/4" = 1'-0"30

CHEMO TLT 160A SOUTH

1/4" = 1'-0"31

CHEMO TLT 160A WEST

Revisions: Date:

5/15/20

M1802

M1801

A5180

"A5146

A5145

A1132

M4200

A5078

A5080 A5075

A5107

IN

FURR-DN

F3200

E0948

A5107

A5080

M1802

FURR-DN

PT-3

M1801

M1802

A5180

E0948

A1014

A5146

IN

F3200

EQ EQ

1' - 2" 3' - 6"

1 3/8"

A5078

IN

CORNER GAURD

FURR-DN

A6046

M4200

A1132

A5080

M3072

M3072

A5108

A5107

F0205

M1802

E0948

PT-3

A5107 A5107

A5200A5080

ADA GRAB BARS

A5145

P9050

A5090

A5200

ADA GRAB

BARS

A5075

A1066

P3100

P9050A5090 ADA GRAB

BARS

A5107

"5

A1066

P3100

A5107P6350

A5080 A5075

P3100

A1107

M0505

M0765

PT-3

A5107

CD021

A5105

A5180

1' - 8"

M0505

F3200

FURR-DN

A5180

CD021

A5107

A5105

1' - 8"A1107

M0505

A5145M0765

M0755

FURR-DN

IN

5/8" GYP. BD.

COLUMN FURRING

CORNER GUARDS

WALL BASE

HANDRAIL /

GUARD RAIL

EQ EQ EQ

1/4" TEMPERED

BUTT GLAZING

1/8" OPEN GAP

BETWEEN GLASS

PANELS

LAY-IN CEILING

CORNER GUARD

RECESSED

ALUMINUM

TRACK TO

RECEIVE GLASS

M1620

A5077

HANDRAIL/ GUARDRAILWALL BASE TYPICAL,

AS SCHEDULED

4' - 0"

18 18

UL752 GLASS

COUNTER W/

BRACKETS

4' - 0"

LOCKABLE WINDOWS

PT-3

A5107

M3070

A5145

M7040

M4267

M1405

A5200

A5090

STALL DOOR WALL BEYOND

WT-2

WT-1

3' - 2" 4' - 9 1/8"

UL752 IMPACT

RESISTANT GLASS

7' - 9 3/4"

MASS WAITING

BEYOND

PT-3

INTERIOR ELEVATION NOTES

1. REF: FOR TYPICAL TOILET WALL ELEVATIONS.

2. REF: MEP DRAWINGS FOR SPECIFIC ELEC. INFORMATION.

3. CORNER GUARDS TYPICAL, REFER SPECIFICATIONS.

4. REF: AE / 401 FOR EQUIPMENT SCHEDULE

5. ALL CABINETS L1 UNLESS NOTED OTHERWISE.

6. ALL COUNTERTOPS SS1 UNLESS NOTED OTHERWISE.

7. ALL WALL PT-2 FIELD COLOR UNLESS NOTED OTHERWISE.

8. MILLWORK CONTRACTING SUB TO VERIFY ALL SPACES

BEFORE SUBMITTING SHOP DRAWINGS.

/28 IN203

SLIDING BULLET

RESISTANT WINDOWS

PT-3

PT-4

WT-1

WT-2

WT-1

F3200

1' - 6"

A5145

F2000

A5108

A5105

A5107

CD021

FURR-DN

A5077

A5078

M0755 M0765

M0750

A1107

M1405

M0505

M4267

A5145

M7040

M4267

M1405

M0505 PT-3F3200

A5105

A5107

A5108

A5180

F2000

PT-3

CD021

A1107 M0755

M0765 M0750

M4267

M7040

M0505

M14054

A5108

R6200

C01C0

CT020

A5099

A5107

F2010

EQ EQ EQ

LOCKABLE

UPPERS

IN

IN

3' - 0"

C04G0

M1801

M3150 M3150CT020

IN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

Wichita, KS

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSULTANT

B

IM

/1

-V A

W

IC

H

IT

A /V

A

W ic h it a

C e n tr a l.

rv t

/2

/2

:5

:1

P

M

IN203

INTERIOR ELEVATIONS

Prime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

589A7-19-401

Building 1

Conrad Pierce General Engineer/COR

2020.05.15 BJM JRC

1/4" = 1'-0"1

EXAM / TELEMED 143 NORTH

1/4" = 1'-0"2

EXAM / TELEMED 143 EAST

1/4" = 1'-0"3

EXAM / TELEMED 143 SOUTH

1/4" = 1'-0"4

EXAM / TELEMED 143 WEST

1/4" = 1'-0"5

EXAM RM 142 NORTH

1/4" = 1'-0"6

EXAM RM 142 EAST

1/4" = 1'-0"7

EXAM RM 142 SOUTH

1/4" = 1'-0"8

EXAM RM 142 WEST

1/4" = 1'-0"9

CHEMO TLT. 169 NORTH

1/4" = 1'-0"10

CHEMO TLT. 169 EAST

1/4" = 1'-0"11

CHEMO TLT. 169 SOUTH

1/4" = 1'-0"12

CHEMO TLT. 169 WEST

1/4" = 1'-0"13

SOILED STOR. 170 SOUTH

1/4" = 1'-0"16

INFUSION BAY 164 EAST

1/4" = 1'-0"17

INFUSION BAY 164 SOUTH

1/4" = 1'-0"18

CHEMO TRTMT 175 SOUTH

1/4" = 1'-0"19

CHEMO TRTMT 175 WEST

1/4" = 1'-0"20

CORRIDOR 168A NORTH

1/4" = 1'-0"21

CORRIDOR 168A SOUTH

1/4" = 1'-0"23

INTERVIEW EAST

1/4" = 1'-0"14

SOILED STORAGE NORTH

1/4" = 1'-0"15

INFUSION BAY NORTH

1/4" = 1'-0"25

WOMEN'S TLT 128 SOUTH

0 2' 4' 8'

1/4" = 1'-0"

1/4" = 1'-0"22

INTERVIEW NORTH

1/4" = 1'-0"24

INTERVIEW SOUTH

1/4" = 1'-0"26 Elevation 1 - a

1/4" = 1'-0"27 Elevation 2 - a

1/4" = 1'-0"28

TYPICAL TLT.

1/4" = 1'-0"29

INFUSION BAY 166.1 NORTH

1/4" = 1'-0"30

INFUSION BAY 166.1 EAST

1/4" = 1'-0"31

INFUSION BAY 166.1 SOUTH

1/4" = 1'-0"32

INFUSION BAY 166.1 WEST

1/4" = 1'-0"33

CHEMO TRTMT 179-1 NORTH

1/4" = 1'-0"34

CHEMO TRTMT 179-1 EAST

1/4" = 1'-0"35

CHEMO TRTMT 179-1 WEST

1/4" = 1'-0"39

MEDS 172-1 WEST

1/4" = 1'-0"38

MEDS 172-1 SOUTH

1/4" = 1'-0"37

MEDS 172-1 EAST

1/4" = 1'-0"36

MEDS 172-1 NORTH

2' - 0" 3/4"

/2

SINK & HARDWARE

REFER MEP

/2

M

IN

/2

MIN.

11"

M

IN

8"

1/2" SOLID

SURFACE,

WATERFALL EDGE

ON 3/4" PLYWOOD

REMOVEABLE

LOWER PANELS

O R

R E

F

E L

E V

SS BACKSPLASH RE:

ELEVATIONS

1 1/2" GROMMET

WALL BASE

/2

1/2" SOLID SURFACE,

WATERFALL EDGE ON

3/4" PLYWOOD

2' - 1" OR 1' - 6" AS NOTED

RE: PARTITION

TYPES

CONCEALED BRACKETS

@ 48" O.C. MAX

1/2"

8"

1/2" SOLID SURFACE,

WATERFALL EDGE ON 3/4"

PLYWOOD

1 1/2" GROMMET

WALL BASE

/2

/2

1/2" SOLID SURFACE,

WATERFALL EDGE ON

3/4" PLYWOOD

2' - 1" OR 14" AS NOTED

RE: PARTITION

TYPES

CONCEALED BRACKETS

@ 48" O.C. MAX (TYP.)

IMPACT RESISTANT WINDOWS,

REF: PLANS & ELEVATIONS

/4

/4

/2

/4

3/4" SUBSTRATE W/

LAMINATE TYP ON

EXPOSED SURFACES

BASE RE: SCHEDULE

ADJUSTABLE SHELVES

RE: PARTITION TYPES

1/2" SOLID SURFACE,

WATERFALL EDGE ON 3/4"

PLYWOOD

2' - 0 1/2" 1/2"

U P

T O

PROVIDE

WOODBLOCKING TYP.

/2

/2

3/4" SUBSTRATE W/

LAMINATE ON EXPOSED

SURFACES

BASE RE: SCHEDULE

ADJUSTABLE SHELVES

RE: PARTITION TYPES

1/2" SOLID SURFACE,

WATERFALL EDGE ON 3/4"

PLYWOOD

2' - 0 1/2" 1/2"

SS-1 REF: ELEVATIONS

/4

/4

/4

/2

WHITE

MELAMINE

INTERIOR TYP

3/4" X 3/4"

MAPLE

NOSING

1/2"

2' - 0 1/4"

O

R

R E

E

L E

V

SOLID SURFACE

COUNTERTOP ON

3/4" PLYWOOD

/4

/4

/4

/2 "1

/4

3"

3/4" SUBSTRATE W/

LAMINATE ON

EXPOSED

SURFACES

BASE RE:

SCHEDULE

1/2" SOLID SURFACE,

WATERFALL EDGE ON 3/4"

PLYWOOD

2' - 0 1/2" 1/2"

SS-1 REF: ELEVATIONS

WHITE MELAMINE

INTERIOR, TYP.

1' - 1"

V A

R

IE

S S

E E

E L E

V A

T

IO

N S

3/4" SUBSTRATE W/

LAMINATE ON

EXPOSED SURFACES

8'-0"

7'-0" MAX

METAL STUD AND GYP BD

FURR DOWN AT FRONT

AND SIDES OF UPPER

MILLWORK

1' - 1"

3/4" SUBSTRATE W/

LAMINATE ON

EXPOSED SURFACES

7'-0"

WHITE MELAMINE

INTERIOR

METAL STUD AND GYP BD

FURR DOWN AT FRONT

AND SIDES OF UPPER

MILLWORK

/4

/4 "6

/4

"1

/2

3"

3/4" SUBSTRATE W/

LAMINATE ON EXPOSED

SURFACES

SS COUNTERTOPS &

BACKSPLASH TYP RE:

ELEVATIONS

U P

T O

/4

/2

/4

3/4" SUBSTRATE W/

LAMINATE ON EXPOSED

SURFACES

BASE RE: SCHEDULE

RE: PARTITION TYPES

1/2" SOLID SURFACE,

WATERFALL EDGE ON 3/4"

PLYWOOD

2' - 0 1/2" 1/2"

LEVEL 1

0"

M

GYP BD WALL BEYOND

REFERENCE IN501 FOR

COUNTERTOP AND

BACKSPLASH FINISHES

DRYWALL EDGE TRIM

TO REINFORCE

CORNERS (TYP.)

GUARDRAIL/HANDRAIL

5/8" GYP. BD. ON 3 5/8"

METAL STUDS

RUBBER BASE

REF. FINISH SCHED.

FLOORING

REF. FINISH SCHED.

LAY-IN CEILING GRID

TRIM EDGES

LAY-IN CEILING TILES

AND GRID SYSTEM

LAY-IN CEILING TILES

LIGHTING - REF.

ELECTRICAL

METAL STUD TRACK

AND FRAMING RAN TO

DECK FOR SUPPORT

OF GLASS SYSTEM

GYP. BD. WALL AND

COLUMN BEYOND

GYP. BD. WALL AND

COLUMN BEYOND

RECESSED ALUMINUM

TRACK ATTACHED TO

METAL STUD TRACK TO

RECIEVE GLASS

RECESSED ALUMINUM

TRACK ATTACHED TO

METAL HEADER STUD

TRACK TO RECIEVE

GLASS

1/4" TEMPERED

BUTT-GLAZED

GLASS SYSTEM

1/4" TEMPERED

BUTT-GLAZED

GLASS SYSTEM

BUMPER RAIL

/2

3/4" SUBSTRATE W/

LAMINATE ON EXPOSED

SURFACES

BASE RE: SCHEDULE

ADJUSTABLE SHELVES

RE: PARTITION TYPES

3' - 0"

WHITE MELAMINE

INTERIOR

METAL STUD AND GYP BD

FURR DOWN AT FRONT

AND SIDES OF UPPER

MILLWORK

3/4" SUBSTRATE W/

LAMINATE ON EXPOSED

SURFACES

BASE RE: SCHEDULE

RE: PARTITION TYPES

3' - 0"

ONE PIECE

REMOVEABLE KICK

EQUIPMENT, SEE SHEET IN102

WHITE MELAMINE

INTERIOR

METAL STUD AND GYP BD

FURR DOWN AT FRONT

AND SIDES OF UPPER

MILLWORK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

Wichita, KS

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSULTANT

B

IM

/1

-V A

W

IC

H

IT

A /V

A

W ic h it a

C e n tr a l.

rv t

/2

/2

:5

:1

P

M

IN210

INTERIOR SECTIONS & DETAILS

Prime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

589A7-19-401

Building 1

Conrad Pierce General Engineer/COR

2020.05.15 BJM JRC

1" = 1'-0"1

ADA SINK

1" = 1'-0"3

DESK SECTION

1" = 1'-0"4

DESK & HIGH COUNTER

1" = 1'-0"5

TYP SECTION AT MILLWORK

1" = 1'-0"9

MILLWORK - DOORS

1" = 1'-0"2

MILLWORK - DOOR & DRAWER

1" = 1'-0"8

MILLWORK DRAWERS

1" = 1'-0"10

TYP. UPPER - DOORS

0 6" 1' 2'

1" = 1'-0"

1" = 1'-0"11

UPPER - DOORS

1" = 1'-0"6

MILLWORK - 3 DRAWERS 30"

1" = 1'-0"7

COUNTER W/ DRAWER

3/4" = 1'-0"12

NURSE STATION SECTION

6" 1'-6"1'0

1 1/2" = 1'-0"

1' 3'2'0

3/4" = 1'-0"

1" = 1'-0"13

MILLWORK - DOORS FULL HEIGHT

1" = 1'-0"14

MILLWORK - DOORS FULL HEIGHT @ WARMING

SYMBOL MATERIAL VENDOR PATTERN / SIZE / COLOR REMARKS

FINISH SCHEDULE NOTE: ALL FINISHES TO BE APPROVED BY OWNER.

VERIFY W/ ARCHITECT PRIOR TO ORDERING MATERIAL.

BASE MATERIAL

WALL MATERIAL

MILLWORK MATERIAL

LUXURY VINYL TILE

FLOOR MATERIAL

NOTE:

1. PROVIDE SCHLUTER - JOLLY EDGE TRIM AT ALL EXPOSED EDGES OF TILE - SATIN SS.

2. PROVIDE SEAM TREATMENTS AT WAINSCOT AS NOTED.

3. PROVIDE 48" CORNER GUARDS AT CORNERS TYPICAL, SET ABOVE BASE FINISH, REFER SPECIFIACTIONS.

4. PROVIDE RUBBER BASE TYPICAL THROUGHOUT UNLESS NOTED OTHERWISE. REFER INTERIOR ELEVATIONS.

5. ALL WALLS PT-2 UNLESS NOTED OTHERWISE.

RSF-1

RSF-2

CP-1

RB

PT-1

SS1

L1

PT-2

WT-3

MOHAWK GROUP

CT-1

VCT-1

URBAN NATIVE WOOD - CARMELLO

LUXURY VINYL TILE

CARPET TILE MILLIKEN

CERAMIC TILE PORCELANOSA

ARMSTRONG

URBAN NATIVE WOOD - ZEN

RUBBER BASE SHAW CONTRACT 4" COVE BASE - NIGHT 0066

PLASTIC LAMINATE FORMICA CHESTNUT WOODLINE 5884

PAINT

PAINT

PAINT

PT-3

PT-5

LOBBY WALLS INPRO - PALLADIUM 3D TRIM

SHERWIN WILLIAMS SW 9166 DRIFT OF MIST

SHERWIN WILLIAMS

SHERWIN WILLIAMS

SHERWIN WILLIAMS

SW 7008 ALABASTER

SW 9177 SALTY DOG

SW 2848 ROYCROFT PEWTER

SOLID SURFACE HANSTONE METROPOLITAN

CEILING MATERIAL

AT ACOUSTICAL CEILINGS

PAINT

FIELD COLOR

WT-1 CERAMIC TILE SPECIALTY TILE

WT-2 ACCENT CERAMIC TILE TILEBAR ACCENT WALL TILE

VINYL COMPOSITION TILE

MOHAWK GROUP

WSF-1 SHEET FLOORING

OCEAN CERAMIC TILE - CALIZA

STANDARD EXCELON - SANDY BEACH

SHADEBOX LINES - DARK 12" x 24"

NOBLE METALLIC CERAMIC - SHADOW

AMERICAN WALNUT - 0555

WALL TILE FOR RESTROOMS

HANDRAILS AND CORNER GUARDS

CORNER GUARD

INPRO 800 HANDRAIL - SILVER - 0105HANDRAIL

INPRO 150 SURFACE MOUNT - SILVER - 0105

EP-1 EPOXY FLOOR SIKAFLOOR CUSTOM COLOR

PATH PTH264 STREAM

5 1/2" HEIGHT

ACCENT COLOR

DOOR FRAMES

ACCENT COLOR

PAINTPT-4 SHERWIN WILLIAMS SW 7072 ONLINE ACCENT COLOR

ARMSTRONG STANDARD EXCELON - SANDY BEACH

REFER SPECIFICATIONS

MILLWORK / DOORS

WT-4 WAINSCOT INPRO - PALLADIUM SHEET WHITE SAND - 0103 RE: INTERIORS

PANELS & 4" MOULDINGS TYPICAL

INPRO 2500 CHAIR RAIL - SILVER - 0105CRASH RAIL / TRIM 2" HEIGHT

3" WINGS TYPICAL

TILE - CONCRETETILE - LVT / VCT

CONCRETE

SLAB

DOOR

CENTERLINE OF

DOOR / TRANSITION STRIP

VINYL

FLOORING

DOOR

DOOR STOP

ADA COMPLIANT

RUBBER TRANSITION

STRIP

DOOR STOP / FRAME

AUTO DOOR BTM.

WHERE SPECIFIED

THIN SET TILE

THIN SET

TILE

PROVIDE SMOOTH TRANSITION

MILL FINISH ALUMINUM

TRANSITION STRIP -

CENTERLINE OF

DOOR / TRANSITION

DE

NOTE:

ALL TRANSITIONS TO COMPLY WITH

ADA/ANSI REQUIREMENTS AND BE THE FULL

LENGTH AND/OR WIDTH OF ANY OPENING

LVT / VCT - CARPETCONC - CARPET

TILE - CARPET

CENTERLINE OF DOOR /

TRANSITION STRIP

CENTERLINE OF DOOR

/ TRANSITION STRIP

DOOR STOP / FRAME

ADA COMPLIANT

RUBBER TRANSITION

STRIP

DOOR STOP / FRAME

DOOR

SEALED CONCRETE

FLOORING

DOOR

THIN SET TILE

TOP TO BE FLUSH

WITH ADJACENT

FLOORING CONCRETE SLAB

MILL FINISH ALUMINUM

TRANSITION STRIP -

CENTERLINE OF DOOR /

TRANSITION STRIP

DOOR STOP / FRAME

DOOR

CARPET TILES

AUTO DOOR BTM.

WHERE SPECIFIED

CONCRETE

SLAB

CARPET

TILES

CONCRETE SLAB

CARPET TILES

ADA COMPLIANT

RUBBER TRANSITION

STRIP

VCT

A

BC

MILL FINISH ALUMINUM

TRANSITION STRIP - PROVIDE

SMOOTH TRANSITION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

Wichita, KS

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSULTANT

B

IM

/1

-V A

W

IC

H

IT

A /V

A

W ic h it a

C e n tr a l.

rv t

/2

/2

:5

:1

P

M

IN501

ROOM FINISH SCHEDULE /

TRANSITION DETAILSPrime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

589A7-19-401

Building 1

Conrad Pierce General Engineer/COR

2020.05.15 BJM JRC

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME

ROOM

CODE BASE FLOOR

WALL FINISHES CEILING SOUND

PROTECTION COMMENTSNORTH SOUTH EAST WEST MATL HT

125-1 ACCESSIBLE

VESTIBULE

- RB EP-1 GWB-PT-4 GWB-PT-4 GWB-PT-4 PT-4 GWB 8'-2" 1

126-1 VESTIBULE - RB EP-1 GLASS GLASS GLASS GLASS GWB 10'-2" 1

127-1 CORRIDOR - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 AT 8'-0" 1

128-1 WOMEN'S TLTF1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2

12", WT-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2 12",

WT-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12",W-1 WAINSCOT 24"

AT 8'-0" STC 40 3

129-1 MAS WAITING WRC01 RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0"

129A-1 TELECOM - RB SL CONC GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 AT 8'-0" 1

130-1 INTERVIEW - RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1

131-1 IT CLOSET - RB SL CONC GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 AT 8'-0" 1

132-1 INTERVIEW - RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1

133-1 MAS WORK AREA - RB CP-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 GWB-PT-1 AT 8'-0"

134-1 RELEASE OF INFO - RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 AT 8'-0" 1

135-1 MAS CHIEF OFA09 RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1

136-1 DEPT CHIEF OFA09 RB CP-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB-PT-1 AT 8'-0" 1

138-1 SHARED LOUNGE SL001 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0" 1

139-1 WAITING RB RSF-1,

RSF-2

GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 AT 8'-0" 1

140-1 SEC WORK SEC01 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

141-1 CORRIDOR RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

142-1 EXAM ROOM EXRG3 RB VCT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB LAY-IN PANELS 8'-0" STC 40 1

143-1 EXAM / TELE MED RB VCT-1 GWB-PT-1 GWB-PT-1 GWB-PT-1 GWB-PT-3 GWB LAY-IN PANELS 8'-0" STC 40 1

160-1 PROCEDURE ROOM EXRG6 RB WSF-1 GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0" 1

160A-1 CHEMO TOILET TLTU1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2 12",

WT-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12",W-1 WAINSCOT 24"

AT 8'-0" STC 40 3

161-1 HAC - RB SL CONC GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"

162-1 STORAGE - RB VCT-1 GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"

162A-1 ELECTRICAL - RB SL CONC GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"

164-1 INFUSION BAY - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 AT 8'-0" 2

165-1 NURSE STATION NSTA4 RB RSF-1 GWB-PT-3 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

166-1 INFUSION BAY - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

167-1 EXAM ROOM EXRG3 RB VCT-1 GWB-PT-2 GWB-PT-2 GWB-PT-3 GWB-PT-2 GWB LAY-IN PANELS 8'-0" STC 40 1

168-1 CORRIDOR - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

168A-1 CORRIDOR - RB RSF-1,

RSF-2

GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

168B-1 CORRIDOR - - - - - - - -

169-1 CHEMO TOILET TLTU1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2 12",

WT-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12",W-1 WAINSCOT 24"

AT 8'-0"

170-1 SOILED STORAGE USCL1 CT-1 CT-1 GWB-PT-4 WT-1 WAINSCOT 60" & WT-2 12",

GWB-PT-4

GWB-PT-4 GWB-PT-4 AT 8'-0" 1

171-1 NOUR - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-3 AT 8'-0"

172-1 MEDS MEDP1 RB VCT-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

173-1 EYE WASH - RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

174-1 CLEAN LINEN

STORAGE

UCCL1 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

175-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 AT 8'-0"

176-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 GWB-SC-PT-2 AT 8'-0" 2

177-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-3 GWB-SC-PT-3 GWB-SC-PT-2 AT 8'-0" 2

178-1 NURSE STATION NSTA4 RB RSF-1 GWB-PT-2 GWB-PT-3 GWB-PT-2 GWB-PT-2 AT 8'-0"

179-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-3 GWB-SC-PT-2 AT 8'-0" 2

180-1 CHEMO TOILET TLTU1 WT-1 CT-1 WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2 12",

WT-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12", W-1 WAINSCOT 24"

WT-1 WAINSCOT 60" & WT-2

12",W-1 WAINSCOT 24"

AT 8'-0" STC 40 3

181-1 STERILE STOR - RB SL CONC GWB-PT-4 GWB-PT-4 GWB-PT-4 GWB-PT-4 AT 8'-0"

182-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 AT 8'-0" 2

183-1 CORRIDOR - RB RSF-1,

RSF-2

GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

184-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 AT 8'-0" 2

185-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-3 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 AT 8'-0" 2

186-1 CHEMO TRTMT OPCT1 RB RSF-1 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-2 GWB-SC-PT-3 AT 8'-0" 2

187-1 CRASH CART RCA01 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

188-1 PAT WEIGH-IN EXRG4 RB RSF-1 GWB-PT-2 GWB-PT-2 GWB-PT-2 GWB-PT-2 AT 8'-0"

CORR-1 CORR. - EXISTING BASE EP-1 WT-3 WAINSCOT +48",

GWB-PT-1

WT-3 WAINSCOT +48", GWB-PT-1 WT-3 WAINSCOT +48",

GWB-PT-1

WT-3 WAINSCOT +48",

GWB-PT-1

EL LOB-1 ELEVATOR LOBBY - EXISTING BASE EP-1 WT-3 WAINSCOT +48",

GWB-PT-1

WT-3 WAINSCOT +48", GWB-PT-1 WT-3 WAINSCOT +48",

GWB-PT-1

WT-3 WAINSCOT +48",

GWB-PT-1

LOBBY-1 LOBBY - EXISTING BASE EP-1 PT-1 PT-1 PT-1 PT-1 1

STAIR-E-1 STAIR - - -

STAIR-SE-1 STAIR - - -

NOTE: REFERENCE SHEET A-001 FOR ABBREVIATIONS

3" = 1'-0"1

TRANSITION DETAILS

COMMENTS:

1. WINDOWS TO RECEIVE BLINDS UNLESS NOTED OTHERWISE, IF APPLICABLE. REFER SPECIFICATIONS.

2. PROVIDE ROLLER SHADES, REFER SPECIFICATIONS.

3. PROVIDE OBSCURE GLASS, REFER SPECIFICATIONS.

4. ALL WALL BASE TO BE RUBBER BASE (RB) UNLESS NOTED OTHERWISE. REFER SECHDULES AND INTERIOR

ELEVATIONS.

FIRE PROTECTION GENERAL NOTES

FIRE PROTECTION ABBREVIATIONS

FIRE PROTECTION SYMBOL LEGEND

DESCRIPTIONLINETYPE

FIRE PROTECTION PIPING LINETYPES

FIRE PROTECTION GENERAL NOTES

NEW - BELOW GRADE

SCHEDULE

SPECIFICATIONS

TEMPERATURE

TYPICAL

WITH

MECHANICAL

MINIMUM

FOOT (FEET)

PC

MC MECHANICAL CONTRACTOR

PLUMBINGPLBG

PLUMBING CONTRACTOR

GPM

GAL

GALLONS PER MINUTE

GALLON

GENERAL CONTRACTOR

QTY QUANTITY

TEMP

TYP

SPEC

GC

MECH

MIN

W/

FT

SCH

STAINLESS STEELSS

NOT TO SCALENTS

1. CONTRACTOR SHALL PROVIDE DESIGN FOR SPRINKLER SYSTEMS FOR NEW REMODELED AREA. REFER TO ARCHITECTURAL DRAWINGS

FOR CEILING TYPES, HEIGHTS AND ROOM CLASSIFICATIONS.

2. MODIFY WET SYSTEM SERVING FIRST FLOOR REMODELED AREA.

3. COORDINATE INSTALLATION OF SPRINKLER PIPING AND ALL COMPONENTS WITH OTHER TRADES, OWNER, AND GENERAL CONTRACTOR.

4. FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13, CURRENT EDITION OF THE VA FIRE PROTECTION DESIGN GUIDE. INSURANCE

CARRIER AND ALL APPLICABLE STATE AND LOCAL CODES.

5. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT AND

STRUCTURAL ENGINEER.

6. PROVIDE MINIMUM 10 PSI SAFETY FACTOR.

7. WORKING DRAWINGS INDICATING SPRINKLER HEAD LOCATIONS AND EXPOSED AND CONCEALED PIPING ROUTING SHALL BE PROVIDED TO

THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION FOR APPROVAL.

8. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR ORGANIZING A COORDINATION MEETING WITH OTHER TRADES AND OWNER PRIOR

TO INSTALLATION.

9. SYSTEM PIPING LOCATION: WET SYSTEM PIPING SHALL BE INSTALLED AT HIGHEST ELEVATION POSSIBLE. PIPING SHALL BE INSTALLED

ABOVE ALL MECHANICAL EQUIPMENT, DUCTWORK, AND ALL PLUMBING SYSTEM PIPING. PROVIDE ADEQUATE CLEARANCE TO MECHANICAL

UNITS. FIRE PROTECTION CONTRACTOR SHALL COORDINATE FIRE PROTECTION PIPING PRIOR TO INSTALLATION.

10. PROPERLY TORQUE MECHANICAL TEES TO MANUFACTURER'S RECOMMENDATIONS.

11. FIRE PROTECTION PLANS ARE FOR REFERENCE ONLY. OCCUPANCIES AND AREAS OF PROTECTION NOTED ON THE PLANS SHALL BE

CONFIRMED WITH NFPA 13 AND AUTHORITIES HAVING JURISDICTION. THIS CONTRACTOR SHALL COMPLY WITH ANY CODE REQUIREMENTS

AS REQUIRED.

12. FIRE SEAL ALL PENETRATIONS THRU RATED STRUCTURES TO MAINTAIN FIRE RATING.

13. PROVIDE GUARDS FOR FULLY EXPOSED UPRIGHT SPRINKLER HEADS WITH BRASS FINISH.

14. SPRINKLER HEADS SEMI-RECESSED IN LAY-IN AND HARD CEILINGS SHALL HAVE WHITE FINISH.

FLOOR

FLOOR DRAIN

ADDITIONAL

ALTERNATE

COLUMN

DOWN

ABOVE FINISH FLOOR

ABOVE FINISH GRADE

ELECTRICAL CONTRACTOR

CW COLD WATER

ADDL

ADD ADDENDUM

ADJ ADJUSTABLE

AFG

AFF

ALT

COL

DN

EC

FD

FLR

BELOW GRADEBG

AG ABOVE GRADE

CAST IRONCI

FIRE PROTECTIONFP

FIRE DEPARTMENT CONNECTIONFDC

SHUTOFF VALVE

CHECK VALVE

END CAP

BELL

FIRE DEPARTMENT CONNECTION(FDC)

DOUBLE CHECK VALVE

NEW - ABOVE GRADE

NEW - BELOW GRADE

SCHEDULE

SPECIFICATIONS

TEMPERATURE

TYPICAL

WITH

MECHANICAL

MINIMUM

FOOT (FEET)

PC

MC MECHANICAL CONTRACTOR

PLUMBINGPLBG

PLUMBING CONTRACTOR

GPM

GAL

GALLONS PER MINUTE

GALLON

GENERAL CONTRACTOR

QTY QUANTITY

TEMP

TYP

SPEC

GC

MECH

MIN

W/

FT

SCH

STAINLESS STEELSS

NOT TO SCALENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

2020.05.15

Building 1

589A7-19-401

Conrad Pierce General Engineer/COR

Prime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

Wichita, KS

B

IM

/1

-V A

W

IC

H

IT

A /M

E P

-C E

N T

R A

L -R

.r v t

/2

/2

:5

:1

P

M

FA001

FIRE PROTECTION LEGEND &

DETAILS

Revisions: Date:

TCC KPP

DN

2 3 4 5 6 7 8 9 10 11 12 13

B

C

F

H

I

J

K

N

O

P

EXISTING 6" SPRINKLER PIPE UP

FROM BASEMENT TO UPPER FLOORS

EXISTING SPRINKLER RISER DRAIN

PIPE TO EXTERIORTO REMAIN

NEW ZONE CONTROL

VALVE FOR 1ST FLOOR

INSTALL SPRINKLER

SYSTEM INSPECTORS

TEST DRAIN LINE DN

ALONG WALL TO

EXTERIOR PIT DRAIN

REMODELED AREA - LIGHT HAZARD

EXISTING BUILDING

REMODELED AREA - LIGHT HAZARD

M

10 11 12 13

CHEMO TRTMT

184-1

CHEMO TRTMT

185-1

CHEMO TRTMT

182-1 STERILE STOR

181-1

CHEMO TOILET

180-1

CHEMO TRTMT

179-1

CHEMO TRTMT

177-1

CHEMO TRTMT

176-1

NURSE STATION

178-1

CORRIDOR

183-1

CHEMO TRTMT

175-1

CHEMO TRTMT

186-1

MEDS

172-1 NOUR

171-1

CLEAN LINEN STORAGE

174-1

EYE WASH

173-1

SOILED STORAGE

170-1

EXAM ROOM

167-1

INFUSION BAY

164-1

ELECTRICAL

162A-1

STORAGE

162-1

CORRIDOR

168-1

NURSE STATION

165-1

EXAM / TELE MED

143-1

EXAM ROOM

142-1

CORRIDOR

141-1

SEC WORK

140-1

INFUSION BAY

166-1

CHEMO TOILET

169-1

WAITING

139-1

SHARED LOUNGE

138-1

DEPT CHIEF

136-1

MAS CHIEF

135-1

INTERVIEW

132-1IT CLOSET

131-1

WOMEN'S

128-1

MAS WORK AREA

133-1

PROCEDURE ROOM

160-1

OUTLINE OF PROJECT AREA

OUTLINE OF PROJECT AREA

EXISTING SPRINKLER PIPING &

HEADS TO REMAIN IN LOBBY

REMODELED AREA - LIGHT HAZARD

OUTLINE OF PROJECT AREA

EXISTING SPRINKLER PIPING

& HEADS TO REMAIN IN

CORRIDOR

EXISTING 4" SPRINKLER PIPE UP

FROM BASEMENT TO UPPER FLOORS

REMODELED AREA - LIGHT HAZARD4

4 4

(TYP)

4 (TYP)

4 4 4

OUTLINE OF PROJECT AREA

LOBBY

LOBBY-1

VESTIBULE

126-1

ACCESSIBLE VESTIBULE

125-1

ELEVATOR LOBBY

EL LOB-1

CORR.

CORR-1

MAS WAITING

129-1

INTERVIEW

130-1

RELEASE OF INFO

134-1

HAC

161-1

CORRIDOR

168B-1

STAIR

STAIR-SE-1

CHEMO TOILET

160A-1

OUTLINE OF PROJECT AREA

OUTLINE OF PROJECT AREA

4 4

EXISTING MECHANICAL CHASE

EXISTING

SPRINKLER PIPING

CORRIDOR

127-1

EXISTING SPRINKLER

PIPING & HEADS TO

REMAIN IN CORRIDOR

INSTALL NEW SPRINKLER ZONE VALVE, FLOW ALARM SWITCH AND TAMPER SWITCH

TO SERVE REMODLED AREAS. ZONE VALVE SHALL BE BUTTERFLY TYPE WITH

TAMPER SWITCHES. GATE OR OS&Y VALVES ARE NOT ALLOWED. COORDINATE

WIRING WITH ELECTRICAL OR FIRE ALARM CONTRACTOR.

INSTALL NEW SPRINKLER SYSTEM INSPECTORS TEST DRAIN VALVE AND DRAIN LINE

THRU EXTERIOR WALL ABOVE GRADE. COORDINATE VALVE LOCATION WITH

OWNER AND GENERAL CONTRACTOR.

CONNECT NEW 2 1/2" SPRINKLER MAIN LINE TO EXISTING IN LINE EXPOSED IN

STAIRWELL. FIELD VERIFY SIZE AND LOCATION.

LIGHT HAZARD AREA - PROVIDE NEW SPRINKLER HEADS OR RELOCATE EXISTING

HEADS IN REMODELED SPACE. MODIFY EXISTING SPRINKLER MAINS AND BRANCH

PIPING FOR NEW LAYOUT.

ORDINARY HAZARD GROUP 1 AREA - PROVIDE NEW SPRINKLER HEADS IN

REMODELED SPACE. MODIFY EXISTING SPRINKLER MAINS AND BRANCH PIPING FOR

NEW LAYOUT.

ORDINARY HAZARD GROUP 2 AREA - PROVIDE NEW SPRINKLER HEADS IN

REMODELED SPACE. MODIFY EXISTING SPRINKLER MAINS AND BRANCH PIPING FOR

NEW LAYOUT.

KEYED NOTES

1. COORDINATE WORK WITH ALL TRADES ON SITE.

2. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK.

3. REFER TO GENERAL NOTES ON SHEET FA001.

4. COORDINATE WITH BUILDING OWNER AND FIRE MARSHAL FOR BUILDING FIRE

SUPPRESSION SYSTEM SHUT-DOWN FOR CONNECTING TO AND/OR MODIFYING EXISTING

SYSTEM.

GENERAL NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

2020.05.15

Building 1

589A7-19-401

Conrad Pierce General Engineer/COR

Prime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

Wichita, KS

B

IM

/1

-V A

W

IC

H

IT

A /M

E P

-C E

N T

R A

L -R

.r v t

/2

/2

:5

:1

P

M

FA101

FIRE PROTECTION PLAN FIRST

FLOOR

1/8" = 1'-0"

FIRE PROTECTION PLAN - FIRST FLOOR1

0 4' 8' 16'

1/8" = 1'-0"

Revisions: Date:

B

C

E F

H

I

J

K

N

O

P

10 11 12 13

EXISTING 4" SPRINKLER RISER TO REMAIN

2 1/2"

EXISTING EXPOSED SPRINKLER

PIPE & HEADS IN CORRIDOR &

LOBBY TO REMAIN, FIELD VERIFY

REMOVE ZONE VALVE, FLOW SWITCH

& TAMPER SWITCH FOR INSTALLING

NEW VALVES & SWITCHES

EXISTING EXPOSED SPRINKLER

PIPING & HEADS TO REMAIN

EXISTING 6" SPRINKLER

RISER TO REMAIN

REMOVE ZONE VALVE, TAMPER

SWITCH & FLOW SWITCH FOR

INSTALLING NEW VALVES

2 1/2"

REMOVE FIRE HOSE CABINET

& PIPE CONNECTION

REMOVE 2" SPRINKLER PIPE BACK TO MAIN

REMOVE AND/OR

RELOCATE MAIN

SPRINKLER PIPE FOR

NEW SPACE LAYOUT

REMOVE SPRINKLER SYSTEM

INSPECTORS TEST DRAIN

VALVE, PIPING & EXTERIOR

PIPING

REMOVE AND/OR RELOCATE

MAIN SPRINKLER PIPE FOR

NEW SPACE LAYOUT

REMOVE AND/OR RELOCATE

MAIN SPRINKLER PIPE FOR

NEW SPACE LAYOUT

REMOVE AND/OR

RELOCATE MAIN

SPRINKLER PIPE FOR

NEW SPACE LAYOUT

COORDIANTE WITH GC FOR WALL REPAIR

AFTER REMOVAL OF DRAIN PIPING

REMOVE AND/OR RELOCATE

SPRINKLER HEADS & BRANCH PIPING

FOR NEW SPACE LAYOUT

REMOVE AND/OR RELOCATE

SPRINKLER HEADS & BRANCH PIPING

FOR NEW SPACE LAYOUT

REMOVE AND/OR RELOCATE

SPRINKLER HEADS & BRANCH PIPING

FOR NEW SPACE LAYOUT

REMOVE AND/OR RELOCATE

SPRINKLER HEADS & BRANCH PIPING

FOR NEW SPACE LAYOUT

OUTLINE OF PROJECT AREA

OUTLINE OF PROJECT AREA

OUTLINE OF PROJECT AREA

1. COORDINATE WORK WITH ALL TRADES ON SITE.

2. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK.

3. REFER TO GENERAL NOTES ON SHEET FA001.

4. COORDINATE WITH BUILDING OWNER AND FIRE MARSHAL FOR BUILDING FIRE

SUPPRESSION SYSTEM SHUT-DOWN FOR CONNECTING TO AND/OR MODIFYING EXISTING

SYSTEM.

GENERAL NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Robert J. Dole VA

Medical Center &

Regional Office Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

RENOVATE FOR RELOCATION OF

ONCOLOGY, HEMATOLOGY, AND

DIALYSIS 1ST FLOOR

WICHITA, KS

2020.05.15

Building 1

589A7-19-401

Conrad Pierce General Engineer/COR

Prime Architects

212 N Crawford Ave

Norman, OK 73069

866.226.8071

Gene Lavastida, Owner

Wichita, KS

B

IM

/1

-V A

W

IC

H

IT

A /M

E P

-C E

N T

R A

L -R

.r v t

/2

/2

:5

:2

P

M

FD101

FIRE PROTECTION - DEMOLITION -

FIRST FLOOR

1/8" = 1'-0"

FIRE PROTECTION PLAN - DEMOLITION -FIRST FLOOR1

0 4' 8' 16'

1/8" = 1'-0"

Revisions: Date:

G

DESCRIPTIONLINETYPE

PLUMBING PIPING LINETYPES

DEMOLITION

RECIRC WATER BELOW GRADE

RECIRC WATER

HOT WATER BELOW GRADE

HOT WATER

COLD WATER BELOW GRADE

COLD WATER

VENT BELOW GRADE

VENT ABOVE GRADE

STORM BELOW GRADE

STORM ABOVE GRADE

SANITARY BELOW GRADE

SANITARY ABOVE GRADE

GAS

GENERAL PLUMBING NOTES

PLUMBING ABBREVIATIONS

PLUMBING RENOVATION NOTES

MEDICAL GAS AREA ALARM SCHEDULE

MEDICAL GAS ZONE VALVE BOX SCHEDULE

MED GAS WALL OUTLET SCHEDULE

PLUMBING PIPING LEGEND

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE MANUFACTURER MODEL MOUNT

ROUGH-IN SCHEDULE

FITTINGS AND REMARKSCOLD HOT WASTE VENT

L-1

LAVATORY

(RESTROOMS)

AMERICAN

STANDARD

0355.012 WALL 1/2" 1/2" 1 1/2" 1 1/2"

SINGLE BOWL, COLOR WHITE, 4" CENTER HOLES, FRONT OVERFLOW HOLE. PROVIDE

CHICAGO FAUCETS MODEL 895-317GN2AE36ABCP GOOSENECK FAUCET (1.5 GPM) .

MCGUIRE HD155WC OFFSET GRID STRAINER, 8902C P-TRAP & LFBV2165

QUARTER-TURN SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL SUPPLY LINES.

TRUEBRO LAV GUARD2 #103 E-Z PIPE COVERS. INSTALL THERMOSTATIC MIXING VALVE

TMV-1 BELOW FIXTURE. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.

L-2

LAVATORY

(WOMENS RESTROOM)

AMERICAN

STANDARD

0476.028 COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"

SINGLE BOWL, COLOR WHITE, 4" CENTER HOLES, FRONT OVERFLOW HOLE. PROVIDE

CHICAGO FAUCETS MODEL 895-317GN2AE36ABCP GOOSENECK FAUCET (1.5 GPM).

MCGUIRE HD155WC OFFSET GRID STRAINER, 8902C P-TRAP & LFBV2165

QUARTER-TURN SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL SUPPLY LINES.

TRUEBRO LAV GUARD2 #103 E-Z PIPE COVERS. COORDINATE COUNTERTOP OPENINGS

WITH MILLWORK. INSTALL THERMOSTATIC MIXING VALVE TMV-1 BELOW COUNTERTOP.

L-3

LAVATORY

(SOILED STORAGE)

AMERICAN

STANDARD

0355.012 WALL 1/2" 1/2" 1 1/2" 1 1/2"

SINGLE BOWL, COLOR WHITE, 4" CENTER HOLES, FRONT OVERFLOW HOLE. PROVIDE

CHICAGO FAUCETS MODEL 116.203.AB.1 GOOSENECK FAUCET WITH BATTERY

OPERATED SENSOR (0.5 GPM) . MCGUIRE HD155WC OFFSET GRID STRAINER, 8902C

P-TRAP & LFBV2165 QUARTER-TURN SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL

SUPPLY LINES. TRUEBRO LAV GUARD2 #103 E-Z PIPE COVERS. INSTALL THERMOSTATIC

MIXING VALVE TMV-1 BELOW FIXTURE. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.

WC-1

WATER CLOSET

ADA

AMERICAN

STANDARD

3351.101 WALL 1 1/4" - 4" 2"

COLOR WHITE. PROVIDE SLOAN MODEL G2-8111-1.28 (1.28 GPF) BATTERY OPERATED

SENSOR FLUSH VALVE. PROVIDE BEMIS SEAT MODEL 1655SSCT, OPEN FRONT

ELONGATED SEAT, EXTERNAL CHECK HINGE, COLOR WHITE. PROVIDE ZURN NARROW

WALL CARRIER. ADA INSTALLATION. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.

WC-2 WATER CLOSET

AMERICAN

STANDARD

3351.101 WALL 1 1/4" - 4" 2"

COLOR WHITE. PROVIDE SLOAN MODEL G2-8111-1.28 (1.28 GPF) BATTERY OPERATED

SENSOR FLUSH VALVE. PROVIDE BEMIS SEAT MODEL 1655SSCT, OPEN FRONT

ELONGATED SEAT, EXTERNAL CHECK HINGE, COLOR WHITE. PROVIDE ZURN NARROW

WALL CARRIER. REFER TO ARCHITECT'S PLANS FOR RIM HEIGHT.

S-1 EXAM ROOM SINK ELKAY PSLVR19172 COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"

SINGLE BOWL, STAINLESS STEEL, 6-1/8." DEPTH, OVERFLOW DRAIN OUTLET, 2 FAUCET

HOLES. PROVIDE ELKAY LK174 DRAIN STRAINER. PROVIDE CHICAGO FAUCETS MODEL

895-317GN2AE36ABCP GOOSENECK FAUCET. PROVIDE PALL MEDICAL QDTC DOCKING

STATION WITH QJ212A FILTER CAPSULE INSTALLED ON FAUCET SPOUT OUTLET.

PROVIDE MCGUIRE 8912 P-TRAP, LFBV2165 SERIES SUPPLY STOPS W/FLEXIBLE

STAINLESS STEEL SUPPLY LINES, INSTALL TMV-1 BELOW FIXTURE.

S-2

SINK

SHARED LOUNGE

ROOM 138-1

ELKAY LRAD1919653PD COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"

SINGLE BOWL, STAINLESS STEEL, 6.5" DEPTH, 3 FAUCET HOLES, S.S. DRAIN BASKET.

PROVIDE CHICAGO FAUCET MODEL 786-GN8AE36ABCP GOOSENECK FAUCET. PROVIDE

MCGUIRE 8912 P-TRAP, LFBV2165 SERIES SUPPLY STOPS W/FLEXIBLE STAINLESS

STEEL SUPPLY LINES, INSTALL TMV-1 BELOW FIXTURE. PROVIDE PALL MEDICAL QDTC

DOCKING STATION WITH QJ212A FILTER CAPSULE INSTALLED ON FAUCET SPOUT .

S-3

SINK

NOURISH AREA 171-1

ELKAY LRAD191965PD3 COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/2"

SINGLE BOWL, STAINLESS STEEL, 6.5" DEPTH, 3 FAUCET HOLES, S.S. DRAIN BASKET.

PROVIDE CHICAGO FAUCETS MODEL 786-GN8AE36ABCP GOOSENECK FAUCET.

PROVIDE PALL MEDICAL QDTC DOCKING STATION WITH QJ212A FILTER CAPSULE

INSTALLED ON FAUCET SPOUT OUTLET. PROVIDE MCGUIRE 8912 P-TRAP, LFBV2165

SERIES SUPPLY STOPS W/FLEXIBLE STAINLESS STEEL SUPPLY LINES, INSTALL TMV-1

BELOW FIXTURE.

MS-1 MOP SINK FIAT

TSB-3000

24x24x12

FLOOR 1/2" 1/2" 3" 1 1/2"

PROVIDE FIAT 832AA HOSE & BRACKET, 889-CC MOP BRACKET, MSG 2424 SS WALL

GUARDS. CHICAGO FAUCET MODEL 897-CP, PROVIDE CHECK VALVES ON HOT & COLD

WATER BRANCH PIPING SERVING MOP SINK.

EW-1

SINK WITH EMERGENCY

EYEWASH STATION

ELKAY WCLWO19230SD3 WALL 1/2" 1/2" 1 1/2" 1 1/2"

STAINLESS STEEL WALL MOUNT SINK, 3 FAUCET HOLES, GRID STRAINER & OVERFLOW.

PROVIDE SPEAKMAN SEF-1800-CA-TW FAUCET WITH INTEGRAL EMERGENCY EYEWASH

& BELOW DECK THERMOSTATIC MIXING VALVE. COMPLIES WITH ANSI Z358.1. PROVIDE

MCGUIRE 8912C P-TRAP & LFBV2165CC SUPPLY STOPS. WATTS 6 CHECK STOPS.

TRUEBRO LAV GUARD2 E-Z PIPE COVERS. REFER TO ARCHITECT'S PLANS FOR RIM

HEIGHT. SEE EYEWASH/FAUCET DETAIL 8/P501.

CS-1 CLINICAL SINK

AMERICAN

STANDARD

9504.999.020 FLOOR 1 1/2" 3/4" 4" 2"

COLOR WHITE. PROVIDE AMERICAN STANDARD PEDESTAL BASE 71009-201.081, FRONT

& SIDE RIM GUARDS 7832504075. PROVIDE SLOAN ROYAL FLUSH VALVE 117, CHICAGO

FAUCETS 815-VBCP FAUCET WITH WATTS 8A-C VACUUM BREAKER & CHICAGO FAUCETS

FOOT PEDALS WITH SPRAY HOSE MODEL 910-G777-19KCP. SEE DETAIL 6/P501.

FD FLOOR DRAIN ZURN ZN415-6SZ-P-VP FLOOR - - 2" -

6" SQUARE NICKEL BRONZE STRAINER, CAST IRON BODY ANCHOR FLANGE, CLAMP

COLLAR, ADJUSTABLE COLLAR, ADJUSTABLE STRAINER HEIGHT, VANDAL-PROOF

SECURED TOP, 1/2" TRAP PRIMER CONNECTION.

FCO FLOOR CLEANOUT ZURN ZN1400-SZ-K-VP FLOOR - -

SEE

PLANS

ADJUSTABLE HEIGHT, CAST IRON BODY, ANCHOR FLANGE, SCORIATED SQUARE TOP

WITH NICKEL BRONZE FINISH, VANDAL RESISTANT COVER SCREWS.

WCO WALL CLEANOUT ZURN Z1445-VP WALL - -

SEE

PLANS

CAST IRON CLEANOUT TEE, THREADED BRASS PLUG, PROVIDE ZS1469-VP STAINLESS

STEEL ROUND ACCESS COVER WITH VANDAL RESISTANT SECURING SCREW .

HA-1 HAMMER ARRESTOR WATTS LF15M2 PIPE VARIES - - -

LEAD-FREE CONSTRUCTION, PDI WH201 LISTED, PRE-CHARGED, PERMANENT SEALED

AIR CHAMBER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.

AP-1 ACCESS PANEL ACUDOR

UF-5000 14x14

CLSS

WALL - - - -

14"x14" STEEL, 16 GAGE DOOR & FRAME, 18 GAGE MOUNTING FRAME. CONCEALED

HINGE, CYLINDER LOCK & KEY, STAINLESS STEEL FINISH. CONCEALED FASTENING

POINTS.

TMV-1

THERMOSTATIC MIXING

VALVE

WATTS LFMMV-M1

BELOW

FIXTURE

1/2" 1/2" - -

LEAD FREE MIXING VALVE WITH ADJUSTABLE TEMPERATURE SET-POINT & LOCKABLE,

INTEGRAL CHECK STOPS & STRAINERS, 1/2" INLETS & OUTLET. SET OUTLET TEMP AT

105 DEGREES F. ASSE 1070 LISTED.

WB-1 WATER BOX SIOUX CHIEF 696RG1010PF WALL 1/2" - - -

FIRE-RATED RECESSED WALL ABS BOX WITH FACE PLATE, 1/2" QUARTER TURN BALL

VALVES WITH INTEGRAL WATER HAMMER ARRESTOR, 3/8" OUTLET.

LB-1

LAUNDRY BOX

(ICE/WATER MACHINE)

SIOUX CHIEF 696RG2313PF WALL 1/2" 1/2" 2" 1 1/2"

FIRE-RATED RECESSED WALL BOX, 1/2" QUARTER TURN BALL VALVES WITH INTEGRAL

WATER HAMMER ARRESTORS, 2" WASTE OUTLET. SERVES ICE/WATER MACHINE.

TBV-1

THERMOSTATIC

BALANCING VALVE

CALEFFI 116141AC PIPE - 1/2" - -

LOW LEAD BRASS BODY, ADJUSTABLE OUTLET TEMPERATURE RANGE WITH ADJUSTING

KNOB, CHECK VALVE, TEMPERATURE GAUGE, PROVIDE BALL VALVES ON BOTH SIDES

OF VALVE, COORDINATE HOT RETURN WATER TEMPERATURE WITH BUILDING OWNER.

RD

ROOF DRAIN WITH

OVERFLOW DRAIN

ZURN Z165 ROOF - - 3" -

8-3/8" DIAMETER ROOF DRAIN & OVERFLOW DRAIN COMBINATION, DURA-COATED CAST

IRON BODY, CAST IRON DOME, COMBINATION MEMBRANE FLASHING CLAMP/GRAVEL

GUARD, DECK MOUNTING PLATE. 2" HIGH WATER DAM ON OVERFLOW DRAIN.

DS DOWNSPOUT ZURN Z199 PIPE - - 3" - NICKEL BRONZE BODY, WALL FLANGE AND NOZZLE OUTLET.

TP-1

TRAP PRIMER

(ELECTRONIC)

PRECISION

PLUMBING

PRODUCTS

MPB-500- 115V PIPE 1/2" - - -

ENCLOSURE WITH CONTROL TIMER, SOLENOID VALVE, AIR GAP, 1/2" INLET, 1/2" OUTLET.

120V HARD WIRE CONNECTION. PIPE OUTLET TO HUB DRAIN. INSTALL PER

MANUFACTURERS RECOMMENDATIONS. UNIT SHALL MEET ASSE 1044 & BE U.L. LISTED.

COORDINATE POWER WITH EC.

CCP-1

COLD CIRCULATION PUMP

(BASEMENT)

BELL & GOSSETT NBF-18S PIPE 1/2" - - -

COLD WATER IN-LINE CIRCULATION PUMP, LEAD-FREE BRONZE BODY, WET ROTOR

TYPE, 1/25 HP,120 V. PROVIDE HONEYWELL TEMP CONTROLLER T775B2040 (120V) WITH

(2) WIRED REMOTE LOW VOLTAGE WATER TEMP SENSORS, WIRE PUMP TO

CONTROLLER, WIRE SOLENOID VALVE TO CONTROLLER. COORDINATE WIRING WITH

EC.

SV-1

SOLENOID VALVE

(COLD WATER DUMP)

HAC ROOM 161-1

ASCO RED HAT 8210G002 PIPE 1/2" - - -

COLD WATER VALVE, LEAD-FREE BRASS, LOW VOLTAGE, (NORMALLY CLOSED).

COORDINATE WIRING TO PUMP CONTROLLER WITH EC. PROVIDE 1/2" BALL VALVE ON

DISCHARGE OF SOLENOID VALVE. ASSEMBLY TO DRAIN DOWN DOMESTIC COLD WATER

MAIN WHEN TEMP REACHES 67 DEG F. COORDINATE VALVE OPERATION WITH OWNER.

1. THESE DRAWINGS SHALL NOT BE SCALED. SEE ARCHITECTURAL/CIVIL DRAWINGS FOR

DIMENSIONAL INFORMATION. THIS ENGINEER WILL NOT BE LIABLE FOR MISCALCULATED

PRODUCT TAKE-OFFS DUE TO SCALING OF DRAWINGS.

2. ALL SANITARY PIPING SHALL HAVE A 1/8" PER FOOT SLOPE UNLESS OTHERWISE NOTED. 2"

SANITARY OR SMALLER SHALL HAVE A 1/4" PER FOOT SLOPE.

3. FIELD VERIFY VENT PIPE MAINS IN CONSTRUCTION ZONE. CONNECT NEW BRANCH VENT PIPING

TO EXISTING VENT RISERS UP TO SECOND FLOOR.

4. VALVES AND FITTINGS SHALL BE OF SAME SIZE AS THE LINE ON WHICH THEY ARE LOCATED, UNLESS OTHERWISE INDICATED ON DRAWINGS.

5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES.

6. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND

CONNECTING ALL SANITARY AND WASTE PIPING AND NOTIFY ENGINEER OF ANY DISCREPANCIES.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING

INTEGRITY OF ALL PIPING AND PENETRATIONS.

8. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH

NO CHANGES IN SIZING.

9. CHANGES IN THE DIRECTION OF SANITARY DRAIN PIPING SHALL NOT BE MADE WITH FITTINGS

WHICH WILL CAUSE EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER

ADVERSE EFFECT UNLESS PHYSICALLY IMPOSSIBLE (I.E.: USE OF SANITARY TEE IN A HORIZONTAL

CONNECTION, USE OF A DOUBLE SANITARY TEE IN A VERTICAL STACK, IN GENERAL, USE OF

SHORT-RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK CONNECTION).

10. CONTRACTOR SHALL GIVE 48 HOURS HOUR EMERGENCY LOCATE NOTICE TO APPLICABLE UTILITY

COMPANY PRIOR TO PERFORMING WORK INVOLVING UTILITIES.

11. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL

SANITATION FOUNDATION.

12. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. PIPING EXPOSED

SHALL BE SLOPED AND PAINTED TO MATCH ARCHITECTURAL FINISHES. PIPING IN MECHANICAL

ROOMS MAY BE EXPOSED.

13. SITE UTILITY CONNECTIONS SHALL BE PROVIDED ON CIVIL DRAWINGS. ALL SERVICES SHOWN ON

THIS SET OF PLANS TERMINATE 5'-0" FROM BUILDING, UNLESS SHOWN OTHERWISE ON DRAWINGS.

PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SITE UTILITIES. (INC. CLEAN OUTS, INCREASES, BACKWATER VALVES, ETC.)

14. COORDINATE WITH ARCHITECT/GENERAL CONTRACTOR FOR INSTALLATION OF HOSE BIBS.

HEIGHT OF INSTALLATION SHALL BE DETERMINED IN FIELD.

15. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE

TO BE CONNECTED BEFORE INSTALLATION OF NEW SEWER LINE.

16. ALL VENTS THROUGH ROOF SHALL BE MIN. 10'-0" FROM ANY AIR INTAKES.

17. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS.

18. CONTRACTOR SHALL ROUGH-IN ALL WASTES AND SUPPLIES TO SPECIAL EQUIPMENT ACCORDING

TO MANUFACTURER'S SHOP DRAWINGS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE

VALVED. INSTALL VACUUM BREAKERS WHERE REQUIRED BY CODE.

19. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR

TO DROP FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY

NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND

LOCATION APPROVED BY STRUCTURAL ENGINEER. PROVIDE LINK-SEALS IN ALL PENETRATIONS

OF EXTERIOR WALLS.

20. ALL PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE IN PROVIDED CEILING SPACE.

21. COORDINATE PIPING INSTALLATION AS TO NOT INTERFERE WITH HVAC EQUIPMENT ACCESS.

22. ANY ERRORS OR AMBIGUITIES IN THE PLANS AND/OR SPECIFICATIONS THAT ARE DISCOVERED BY

THE CONTRACTOR SHALL BE REPORTED TO THE ARCHITECT/ENGINEER BEFORE WORK IS

STARTED. OMISSION OF PARTICULAR REFERENCE TO ANY ITEM NECESSARY FOR COMPLETE

INSTALLATION AND PROPER OPERATION THEREOF SHALL NOT RELIEVE THE CONTRACTOR OF THE

RESPONSIBILITY OF FURNISHING THE SAME AT NO EXTRA COST. THE CONTRACTOR IS

RESPONSIBLE FOR REVIEWING ALL CONSTRUCTION DOCUMENTS FOR INFORMATION PRIOR TO

BID.

23. VERIFY WITH ARCHITECT ON ALL EQUIPMENT AND FIXTURES REQUIRING PLUMBING PRIOR TO BID.

COORDINATE EXACT LOCATIONS AND CONNECTIONS.

24. ALL WORK SHALL BE IN COMPLIANCE WITH STATE AND LOCAL CODES INCLUDING INTERNATIONAL

PLUMBING CODE 2015 AND MEDICAL GAS CODE NFPA 99.

25. CONTRACTOR SHALL PAY ALL FEES, PERMITS, LICENSES, ETC. NECESSARY FOR PROPER

COMPLETION OF WORK.

26. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

27. PROVIDE TRAP PRIMER CONNECTION TO ALL FLOOR DRAINS, FLOOR SINKS AND OPEN SITES.

WHERE TRAP GUARDS ARE PROHIBITED, PROVIDE ELECTRONIC TRAP PRIMER VALVE W/MANIFOLD

FOR EVERY FOUR(4) FIXTURES OR EQUAL.

28. PROVIDE RIGID CONNECTION BETWEEN ALL SENSOR VALVES AND SENSOR LOCATION.

29. MOUNT ALL FIXTURE SENSORS PER MANUFACTURER'S RECOMMENDATIONS.

30. PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE SYSTEMS AT END OF RUNS, CHANGES

IN DIRECTION AND ELSEWHERE AS INDICATED ON THE DRAWINGS. IF A CONFLICT OCCURS

BETWEEN THE CONTRACT DRAWINGS AND THE SPECIFICATIONS, INDICATE THAT THE

SPECIFICATIONS OR MORE STRINGENT CONDITION SHALL GOVERN, UNLESS INSTRUCTED

OTHERWISE.

31. ACCURATE "AS-BUILT" DRAWINGS SHALL BE MAINTAINED DURING THE CONSTRUCTION.

SCHEDULE

SPECIFICATIONS

TEMPERATURE

TYPICAL

WITH

MECHANICAL

MINIMUM

EQUAL

FLOOR

FLOOR DRAIN

FOOT (FEET)

ADDITIONAL

ALTERNATE

COLUMN

DOWN

PC

MC MECHANICAL CONTRACTOR

PLUMBING

ABOVE FINISH FLOOR

ABOVE FINISH GRADE

ELECTRICAL CONTRACTOR

F

PLBG

PLUMBING CONTRACTOR

CLEANOUT

FCO

VTR

HW

CO

CW COLD WATER

GPM

GAL

GALLONS PER MINUTE

GALLON

GENERAL CONTRACTOR

FURNACE

ADDL

ADD ADDENDUM

ADJ ADJUSTABLE

PRES PRESSURE

QTY QUANTITY

SAN SANITARY

TEMP

TYP

SPEC

HOT WATER

GC

MECH

MIN

W/

AFG

AFF

ALT

COL

DN

EC

EQ

FT

FD

FLR

SCH

FLOOR CLEANOUT

WCO WALL CLEANOUT

VENT THRU ROOF

STAINLESS STEELSS

NOT TO SCALENTS

BELOW GRADEBG

AG ABOVE GRADE

NON POTABLE COLD WATERNPCW

WC WATER CLOSET

NATURAL GASNG

RTU ROOFTOP UNIT

GW GREASE WASTE

HWR HOT WATER RETURN

V VENT

EXTERIOR CLEANOUTECO

1. WHERE EXISTING PIPING IS DESIGNATED TO BE REMOVED AND CAPPED, ALL PIPING

SERVING THE DESIGNATED FIXTURE SHALL BE REMOVED FROM WITHIN WALLS TO THE

POINT DESIGNATED ON THE DRAWINGS OR TO A CLEARLY VISIBLE POINT BELOW THE

FLOOR IN THE CRAWL SPACE OR ABOVE THE CEILING. PIPING SHALL BE CAPPED BY

APPROVED CAPPING METHODS UTILIZING PIPE CAPS INTENDED FOR SUCH USE. ALL

CAPS SHALL BE AIRTIGHT AND WATERTIGHT.

2. WHERE EXISTING SURFACES ARE DISRUPTED DUE TO THE REMOVAL OF EXISTING

EQUIPMENT OR PIPING, THIS CONTRACTOR SHALL BE RESPONSIBLE OR THE REPAIR OF

DISRUPTED SURFACES TO MATCH EXISTING ADJACENT SURFACES.

3. SANITARY VENTS NOT TO BE REUSED SHALL BE CAPPED ABOVE THE FIRST FLOOR

CEILING AND LEFT IN PLACE FOR POSSIBLE FUTURE USE.

4. PLUMBING FIXTURES DESIGNATED TO BE REUSED SHALL BE CLEANED AND

MAINTENANCE SERVICED TO OPERATE AS INTENDED.

5. EXISTING CONDITIONS AS SHOWN ON THE DRAWINGS ARE TAKEN FROM ORIGINAL

AND AS-BUILT DRAWINGS OF THE BUILDING AND IN PART ARE UNVERIFIED. FIELD

CONDITIONS SHALL GOVERN. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO

INITIATION OF WORK.

6. ALL EXISTING SANITARY, DOMESTIC WATER, MEDICAL GASES, RAINWATER, AND FIRE

PROTECTION PIPING SHALL BE RELOCATED TO CREATE REQUIRED SPACE FOR

INSTALLATION OF ALL NEW SERVICES FOR NEW CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO H.V.A.C., ELECTRICAL, PLUMBING, AND FIRE PROTECTION TRADES.

CONTRACTOR SHALL INCLUDE ALL NEW PIPING AND FITTINGS REQUIRED AND

RELOCATE ANY AND ALL EXISTING SERVICES.

7. ALL EXISTING PIPING, NOT REMAINING IN SERVICE AFTER NEW CONSTRUCTION,

SHALL BE REMOVED.

8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EXISTING

PLUMBING FIXTURES AND TRIM, PIPING, VALVES, ETC. IN AREAS TO BE DEMOLISHED.

9. ALL EXISTING PLUMBING FIXTURES TO BE REMOVED AND ARE NOT TO BE REUSED

SHALL REMAIN THE PROPERTY OF THE OWNER. DISCARD UNWANTED FIXTURES AT AT

THE DISCRETION OF THE OWNER.

10. PIPING WHICH IS TO REMAIN IN SERVICE SHALL NOT BE DISTURBED. EXISTING PIPING

BROKEN DURING CONSTRUCTION SHALL BE REPLACED WITH NEW PIPING OF THE SAME

SIZE AND MATERIAL.

11. PLUMBING CONTRACTOR SHALL SUBMIT SHOP DRAWINGS APPROVED BY THE

AUTHORITIES HAVING JURISDICTION TO THE ARCHITECT/ENGINEER FOR ANY PIPING

CONFIGURATIONS AND SIZES THAT DIFFER FROM THOSE SHOWN ON PLUMBING

DRAWINGS AS A RESULT OF EXISTING SITE CONDITIONS AND/OR EXISTING PIPING

LOCATIONS.

12. EXISTING BUILDING SEWERS THAT ARE USED WITH NEW BUILDING SANITARY

SEWERS SHALL BE EXAMINED AND TESTED TO CONFORM IN ALL RESPECTS TO ALL

REQUIREMENTS OF PLUMBING AUTHORITY HAVING JURISDICTION AND APPLICABLE

PLUMBING CODES.

13. ALL EXISTING MEDICAL GAS OUTLETS REMOVED SHALL BE TURNED OVER TO THE

OWNER. ALL OUTLETS SHALL BE REMOVED FROM THE WALL AND ALL PIPING SERVING

THE OUTLETS REMOVED TO ABOVE THE CEILING AND CAPPED.

14. ALL EXISTING SANITARY, DOMESTIC WATER, AND RAINWATER PIPING THAT ARE

LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND REMAINING IN SERVICE AFTER

CONSTRUCTION SHALL BE RELOCATED TO NEW WALLS, CHASES, ETC.

15. COORDINATE WITH GENERAL CONTRACTOR TO PATCH ALL EXISTING WALLS,

FLOORS, CEILINGS, ETC., AS REQUIRED BY NEW WORK. SEE SPECIFICATIONS.

16. PROVIDE GUIDELINES FOR CUTTING AND NOTCHING STRUCTURAL MEMBERS FOR

PIPE PENETRATIONS. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER

TRADES PRIOR TO FABRICATION, PURCHASE AND/OR INSTALLATION OF THE WORK. NO

PLUMBING PIPING (DOMESTIC COLD, HOT AND RETURN WATER, SANITARY, STORM,

ETC.) SHALL BE RUN OVER ELECTRICAL, LOW VOLTAGE, TELECOMMUNICATION OR

COMPUTER ROOMS.

17. COORDINATE WITH MECHANICAL CONTRACTOR FOR REQUIRED CONDENSATE DRAIN

LINE DISCONNECTION, MODIFICATIONS AND RECONNECTION AS NECESSARY.

NOTESMODEL NUMBERMANUFACTURERDESCRIPTIONTYPE MED AIRMED VACO2

AA-1 ALLXXXALARM PANEL

NOTESMODEL NUMBERMANUFACTURERDESCRIPTIONTYPE MED AIRMED VACO2

1,2BOX ASSEMBLY

THREE VALVE ZONE

ZB-1 1/2"1 1/4"3/4"

NOTE:

1. PROVIDE BEACON MEDAES REMOTE TRANSDUCERS AS INDICATED IN PLAN. LOCATE IN ZONE VALVE BOX WHERE INDICATED ON PLANS.

2. PRIOR TO INSTALLATION FIELD VERIFY FINAL LOCATION OF ALARM WITH ARCHITECT AND GENERAL CONTRACTOR REP.

3. LOW VOLTAGE WIRING FROM REMOTE TRANSDUCERS TO AREA ALARM BY PC.

NOTE:

1. PRIOR TO INSTALLATION FIELD VERIFY FINAL LOCATION OF VALVE WITH ARCHITECT AND GENERAL CONTRACTOR.

2. PROVIDE REMOTE TRANSDUCERS IN ZONE VALVE BOX AS INDICATED ON PLANS.

BEACON MEDAES

BEACON MEDAES

NOTES

ALL

TYPE MANUFACTURER

OXYGEN

CATALOG NUMBER

#121040-00BEACON MEDAES

ALLMED VAC #151043-00BEACON MEDAES

ALLMED AIR #151042-00BEACON MEDAES

#M3-A10-OAV

#ZVB3-ABD-ENG

MA MEDICAL AIR

MEDICAL VACUUMMV

OXYGENO2

RD ROOF DRAIN

DOWNSPOUTDS

STORM DRAINSD

OVERFLOW ROOF DRAINORD

OVERFLOW STORM DRAINOSD

CIRCUIT SETTER

BALL VALVE OR SHUT-OFF VALVE

SPRING…

This is the start of the file's text. The full file is on GovTribe.