36E77619R0010 0004 Attachment 2 - Harwood Bldg Lead Paint Survey 05192017 1.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77619R0010-0004000.docx | DOCX document | |
| 36E77619R0010-0004001.pdf | ||
| 36E77619R0010-0003000.docx | DOCX document | |
| 36E77619R0010-0003001.pdf | ||
| 36E77619R0010-0002001.pdf | ||
| 36E77619R0010-0002000.docx | DOCX document | |
| 36E77619R0010-0001000.docx | DOCX document | |
| 36E77619R0010-005.pdf | ||
| 36E77619R0010-006.pdf | ||
| 36E77619R0010-001.docx | DOCX document | |
| 36E77619R0010-002.doc | DOC document | |
| 36E77619R0010-009.docx | DOCX document | |
| 36E77619R0010-007.pdf | ||
| 36E77619R0010-004.pdf | ||
| 36E77619R0010-008.pdf | ||
| 36E77619R0010-003.pdf | ||
| 36E77619R0010_2.docx | DOCX document |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAIN OFFICE:
One Pleasure Island Road Suite 2C Wakefield, Massachusetts 01880
(781) 213-9198
(781) 213-6992 Fax
BRANCH OFFICES:
46 Watergate Lane Barnstable, Massachusetts 02668
(508) 746-5218
(508) 732-0281 Fax
10 Diamond Drive Derry, New Hampshire 03038
(603) 434-5245
(603) 434-5172 Fax www.axiomenv.com
July 6, 2017
Mr. David Webster PDT Architects Project 01225.008 49 Dartmouth Street Portland, Maine 04101
RE: Lead Paint Building Materials Inspection Report, Harwood Building, Veterans Affairs Medical Center, Providence, Rhode Island
VAMC Project: Renovate Harwood Center for Research VAMC Project Number: 650-333
Dear Mr. Webster:
Axiom Partners, Inc. (AXIOM) performed a building materials survey in the Harwood Building (herein “the building”) to identify lead-containing paints (LCPs) prior to building renovations.
The scope of work included the collection of lead paint readings from various painted components on the interior and exterior of the building. An experienced Inspector, Mr. Peter Del Sette, Jr.
performed the survey on May 19, 2017.
LEAD PAINT INVESTIGATION
The lead paint survey was performed to identify lead-containing paints (LCPs) in the building components for compliance with governing regulations for lead in construction. The purpose of the lead survey was to identify representative interior and exterior building components coated with LCPs prior to the renovation project.
AXIOM utilized a Portable X-Ray Fluorescence Analyzer (XRF) to perform the lead paint survey.
The XRF is a hand-held instrument that contains a radioisotopic source and operates on the principle of X-ray fluorescence.
AXIOM used a NITON Model XLp300 which analyzes surfaces quickly, accurately and non-destructively. Surface levels of lead are measured in milligrams per square centimeter (mg/cm2).
This unit can measure the concentration of LCP on surfaces as little as 0.01 mg of lead/cm2.
Testing performed on various painted components revealed that only a few of the coatings contain lead in detectable quantities. A complete listing of the testing results can be found attached to the report, however, the paints listed in Table 1 were found to have significant lead content.
Mr. David Webster Lead Paint Testing Report July 6, 2017 Harwood Building Page 2 VAMC, Providence, RI
TABLE 1
LISTING OF PAINTED MATERIALS WITH SIGNIFICANT LEAD PRESENT
LOCATION COLOR & COMPONENT(S) COLOR
XRF READING
(mg/cm2)*
North Garage Door, West Side Door Casing Brown 18.0
Hall at Room 202/203 Structural Column White 14.2
Room 103 Casing White 13.6
North Garage Door, East Side Door Casing Brown 12.9
Hall at Room 202/203 Structural Beam White 11.5
Hall at Room 200 Structural Column White 10.0
First Floor, Break Room, East Side Structural Beam White 8.8
First Floor, Break Room, Center Structural Beam White 8.1
Basement, NW Stairs Newel Post Lt. Blue 7.3
Hall at 208 Structural Beam White 5.7
Room 100 Structural Beam White 5.5
Basement, NW Stairs Stair Baluster Lt. Blue 3.9
First Floors, SE Stairs Stair Riser Lt. Blue 2.9
Basement, SE Stairs Stair Stringer Lt. Blue 2.6
First Floor Main Hall At 101 Structural Column White 2.4
Hall at 206 Structural Column White 2.4
First Floors, SE Stairs Stair Stringer Lt. Bleu 2.1
Hall at Room 205 Structural Column White 2.1
First Floors, SE Stairs Newell Post Lt. Blue 2.0
North Garage Door, East Side Footing Brown 1.9
Hall at 208 Structural Column White 1.8
Basement, SE Stairs Stair Baluster Lt. Blue 1.7
Hall at 206 Structural Beam White 1.7
Basement, SE Stairs Newel Post Lt. Blue 1.6
Hall at Room 200 Structural Beam White 1.5
Exterior West Side Double Doors D Brown 1.4
* mg/cm2 = Milligrams of Lead per Square Centimeter of area
Based on the lead testing results, AXIOM does not expect that lead abatement will be required unless surfaces with lead paint are to be sanded, blasted with abrasive or cut with a saw.
If hand scraping or abrasive removal is performed, collection of paint chips/abrasive materials and proper disposal may be required (see below). Worker safety requirements should also be evaluated.
WORKER SAFETY - Note that the selected renovation contractor may have specific worker monitoring requirements to satisfy the hazard communication requirements set forth by OSHA
Mr. David Webster Lead Paint Testing Report July 6, 2017 Harwood Building Page 3 VAMC, Providence, RI regulations. Specifically, contractors and subcontractors should be required to comply with OSHA regulations including 29 CFR 1926.62,Lead Exposure in Construction: Interim Final Ruleand 29 CFR 1926.59, Hazard Communication for the Construction Industry. AXIOM recommends providing lead testing data with the selected renovation contractor.
DISPOSAL OF LCPS - The current interpretation of the EPA’s Resource Conservation and Recovery Act (RCRA) requires that waste generated during projects where LCPs are present and will be disposed are tested for the toxicity characteristic of lead in the waste stream. Toxicity Characteristic Leachate Procedure (TCLP) testing is performed to determine whether the waste (construction/demolition debris) must be classified as hazardous because of its lead content or if it can be disposed in a conventional construction and demolition (C&D) landfill. The regulatory limit for lead toxicity is 5.0 milligrams per liter (mg/L) using the EPA reference Method SW846- 7420 for Atomic Absorption Spectroscopy (AAS). Since there are significant lead painted materials that are present, AXIOM recommends TCLP waste stream testing for lead prior to disposal of C&D debris containing lead paint.
LIMITATIONS AND EXCLUSIONS
1. This investigation did not include assessments for the presence of asbestos (prior report was issued regarding asbestos materials in this building), pesticides, herbicides, urea-formaldehyde or Radon, nor any air quality monitoring, or any chemical analyses of soil, surface water, or groundwater at the Site. Furthermore, this study did not include any subsurface exploration, testing or assessment for wetlands.
2. No attempt was made to check the compliance of present or past owners of the Site with Federal, State, or local laws.
3. Testing for lead paint was performed by one or more experienced Industrial Hygienists. It is intended only to satisfy the requirements of OSHA regulations including 29 CFR 1926.62, Lead Exposure in Construction: Interim Final Rule and 29 CFR 1926.59, Hazard Communication for the Construction Industry. This investigation was not performed by an EPA HUD1 or state accredited/licensed lead inspector, which is often required for residential structures where children under the age of six reside.
Please call us if you have any questions or require our assistance.
Sincerely, Peter Del Sette, Jr. Randal D. Ames Inspector Principal/Project Manager
Attachment 1 XRF Data Tables
\VA Providence - Harwood Bldg Lead Survey.docx
1 US Department of Housing and Urban Development
ATTACHMENT 1
XRF DATA TABLES
SAMPLE CODE:
BB-Baseboard; B-Bollards/Bumpers; C/T-Casing/Trim; CL-Ceiling; CR-Chair Rail; D-Door; DC-Door Casing; DJ-Door Jamb; DW-Duct Work; E-Equipment;
FL-Floor; HR- Handrail; HVAC-Fans/Air Handlers; M – Miscellaneous; P-Piping; R-Railing; RD-Radiator; RC-Radiator Cover; SB-Stair Balusters; SH- Shingles/Siding; SR-Stair Riser; SS-Stair Stringer; SR-Stair Railing; ST, Stair Tread; STC-Structural Column; STB-Structural Beam; STM-Structure Misc; W- Wall; UW-Upper Wall; LW-Lower Wall; WSH-Window Sash; WC-Window Casing; WSL-Window Sill
SUBSTRATE TYPE:
W-Wood; G-Gypsum Board; P-Plaster; C-Concrete; CB- Concrete Block; PA-Paneling: T-Tile; M-Metal; B-Brick; U-Unknown
PAINT CONDITION:
1 to 5; 1 = Undamaged (< 5% damage) ; 2 = Slight Damage (6-15% Damage) ; 3 = Moderate Damage (16-25% Damage) ;
4 = Extensive Damage (26-50% Damage) ; 5 = Severe Damage (>50% Damage)
XRF Lead Paint Testing Results Veterans Affairs Medical Center, Harwood Building, Providence, Rhode Island
Location Sample Code
Substrate Condition
XRF
Reading (mg/cm2)
Color
North Garage Door, West Side DC M 2 18.0 Brown
Hall at Room 202/203 STC W 1 14.2 White
Room 103 C C 2 13.6 White
North Garage Door, East Side DC M 2 12.9 Brown
Hall at Room 202/203 STB W 1 11.5 White
Hall at Room 200 STC M 2 10.0 White
First Floor, Break Room, East Side STB M 1 8.8 White
First Floor, Break Room, Center STB M 1 8.1 White
Basement, NW Stairs Newel Post M 2 7.3 Lt. Blue
Hall at 208 STB M 2 5.7 White
Room 100 STB M 1 5.5 White
Basement, NW Stairs SB M 2 3.9 Lt. Blue
First Floors, SE Stairs SR M 2 2.9 Lt. Blue
Basement, SE Stairs SS M 2 2.6 Lt. Blue
First Floor Main Hall At 101 STC M 1 2.4 White
Hall at 206 STC M 2 2.4 White
First Floors, SE Stairs SS M 2 2.1 Lt. Bleu
Hall at Room 205 STC M 2 2.1 White
First Floors, SE Stairs Newell Post M 2 2.0 Lt. Blue
North Garage Door, East Side Footing M 2 1.9 Brown
Hall at 208 STC M 2 1.8 White
Basement, SE Stairs SB M 2 1.7 Lt. Blue
Hall at 206 STB M 2 1.7 White
Basement, SE Stairs Newel Post M 2 1.6 Lt. Blue
Hall at Room 200 STB M 3 1.5 White
Exterior West Side Double Doors D W 2 1.4 Brown
Basement, Former Pistol Range WC W 3 0.6 White
Room 103 STB M 1 0.6 White
Hall at Room 200 C C 2 0.6 White
BB-Baseboard; B-Bollards/Bumpers; C/T-Casing/Trim; CL-Ceiling; CR-Chair Rail; D-Door; DC-Door Casing; DJ-Door Jamb; DW-Duct Work; E-Equipment;
FL-Floor; HR- Handrail; HVAC-Fans/Air Handlers; M – Miscellaneous; P-Piping; R-Railing; RD-Radiator; RC-Radiator Cover; SB-Stair Balusters; SH- Shingles/Siding; SR-Stair Riser; SS-Stair Stringer; SR-Stair Railing; ST, Stair Tread; STC-Structural Column; STB-Structural Beam; STM-Structure Misc; W- Wall; UW-Upper Wall; LW-Lower Wall; WSH-Window Sash; WC-Window Casing; WSL-Window Sill
SUBSTRATE TYPE:
W-Wood; G-Gypsum Board; P-Plaster; C-Concrete; CB- Concrete Block; PA-Paneling: T-Tile; M-Metal; B-Brick; U-Unknown
PAINT CONDITION:
1 to 5; 1 = Undamaged (< 5% damage) ; 2 = Slight Damage (6-15% Damage) ; 3 = Moderate Damage (16-25% Damage) ;
4 = Extensive Damage (26-50% Damage) ; 5 = Severe Damage (>50% Damage)
XRF Lead Paint Testing Results Veterans Affairs Medical Center, Harwood Building, Providence, Rhode Island
Location Sample Code
Substrate Condition
XRF
Reading (mg/cm2)
Color
Front Ext. Flagpole Misc. M 5 0.6 Yellow
Room 105 D M 2 0.5 Blue
Former Weapons Vault W M 2 0.5 Grey
Former Weapons Vault STC M 2 0.30 White
Ext. of Former Weapons Vault HR M 1 0.30 Lt. Blue
Room 109 W CMU 2 0.30 White
Room 111 D M 2 0.30 Blue
Room 208 D W 1 0.30 Lt. Blue
Hall at Room 204 C C 3 0.28 White
Hall at Room 202/203 C C 2 0.25 White
Hall at Room 200 Footing Concrete 2 0.19 Grey
Room 100 C C 2 0.18 White
Room 105 DF M 1 0.17 White
First Floors, SE Stairwell LW CMU 1 0.16 White
Hall at Room 202/203 W C 2 0.16 White
Basement, NW Corner C C 2 0.15 White
Common Wall Rooms 104/105 W GB 2 0.15 White
Basement, NW Stairs SS M 2 0.14 Lt. Blue
Room 208 C C 3 0.13 White
South (Rear) HR M 4 .0.13 Black
Room 101 Duct M 2 0.12 White
Ext. of Former Weapons Vault W CMU 5 0.11 White
Hall at Room 200 DF M 2 0.11 White
First Floor Main Hall at Room 111 W CMU 2 0.10 White
Basement, Hall from Bathroom D W 1 0.09 Lt. Blue
Room 105 W CMU 2 0.09 White
Room 111 W CMU 5 0.09 White
Basement, SE Hall /Storage Room F C 3 0.08 Red
Room 107/108 Common Wall W w 1 0.08 White
Room 203 W C 2 0.07 White
BB-Baseboard; B-Bollards/Bumpers; C/T-Casing/Trim; CL-Ceiling; CR-Chair Rail; D-Door; DC-Door Casing; DJ-Door Jamb; DW-Duct Work; E-Equipment;
FL-Floor; HR- Handrail; HVAC-Fans/Air Handlers; M – Miscellaneous; P-Piping; R-Railing; RD-Radiator; RC-Radiator Cover; SB-Stair Balusters; SH- Shingles/Siding; SR-Stair Riser; SS-Stair Stringer; SR-Stair Railing; ST, Stair Tread; STC-Structural Column; STB-Structural Beam; STM-Structure Misc; W- Wall; UW-Upper Wall; LW-Lower Wall; WSH-Window Sash; WC-Window Casing; WSL-Window Sill
SUBSTRATE TYPE:
W-Wood; G-Gypsum Board; P-Plaster; C-Concrete; CB- Concrete Block; PA-Paneling: T-Tile; M-Metal; B-Brick; U-Unknown
PAINT CONDITION:
1 to 5; 1 = Undamaged (< 5% damage) ; 2 = Slight Damage (6-15% Damage) ; 3 = Moderate Damage (16-25% Damage) ;
4 = Extensive Damage (26-50% Damage) ; 5 = Severe Damage (>50% Damage)
XRF Lead Paint Testing Results Veterans Affairs Medical Center, Harwood Building, Providence, Rhode Island
Location Sample Code
Substrate Condition
XRF
Reading (mg/cm2)
Color
Basement, NW Interior Hall Wall W C 1 0.06 White
Room 100 W CMU 2 0.06 White
Room 101 W CMU 2 0.06 White
Basement, Storage Cage BDE-S1 D W 1 0.05 Lt. Blue
Basement, NW Office W C 1 0.05 White
Basement, Former Pistol Range Wall C 1 0.05 White
Former Weapons Vault D M 2 0.05 Brown
Hall at Room 205 C C 3 0.05 White
Hall at Room 202/203 Footing C 1 0.04 Grey
South (Rear) Utility Shed Soffit W 3 0.04 Green
First Floor, NW Corner RAD M 2 0.03 Grey
Basement, NW Corner W C 2 0.02 White
Basement, NW Corner W C 2 0.02 White
Basement, Weight Room W C 2 0.02 White
Basement, Former Pistol Range Wall C 1 0.02 White
Basement, Former Pistol Range Wall C 1 0.02 White
Room 111 DF M 1 0.02 White
Basement, NW Corner WC M 1 0.01 Brown
Basement, Weight Room C C 2 0.01 White
Basement, Toilet Room WC M 1 0.01 Brown
Basement, Exterior Wall W C 2 0.01 White
Basement, Former Pistol Range Wall C 1 0.01 White
First Floor, NW Corner D M 2 0.01 Blue
First Floor, NW Corner DF M 1 0.01 White
Room 103 W CMU 2 0.01 White
Room 107/108 Common Wall W GB 1 0.01 White
Hall at Room 200 Toe Board W 1 0.01 Grey
Room 204A W CMU 2 0.01 Beige
Exterior General Receiving D M 2 0.01 Brown
Exterior General Receiving DF M 2 0.01 Brown
BB-Baseboard; B-Bollards/Bumpers; C/T-Casing/Trim; CL-Ceiling; CR-Chair Rail; D-Door; DC-Door Casing; DJ-Door Jamb; DW-Duct Work; E-Equipment;
FL-Floor; HR- Handrail; HVAC-Fans/Air Handlers; M – Miscellaneous; P-Piping; R-Railing; RD-Radiator; RC-Radiator Cover; SB-Stair Balusters; SH- Shingles/Siding; SR-Stair Riser; SS-Stair Stringer; SR-Stair Railing; ST, Stair Tread; STC-Structural Column; STB-Structural Beam; STM-Structure Misc; W- Wall; UW-Upper Wall; LW-Lower Wall; WSH-Window Sash; WC-Window Casing; WSL-Window Sill
SUBSTRATE TYPE:
W-Wood; G-Gypsum Board; P-Plaster; C-Concrete; CB- Concrete Block; PA-Paneling: T-Tile; M-Metal; B-Brick; U-Unknown
PAINT CONDITION:
1 to 5; 1 = Undamaged (< 5% damage) ; 2 = Slight Damage (6-15% Damage) ; 3 = Moderate Damage (16-25% Damage) ;
4 = Extensive Damage (26-50% Damage) ; 5 = Severe Damage (>50% Damage)
XRF Lead Paint Testing Results Veterans Affairs Medical Center, Harwood Building, Providence, Rhode Island
Location Sample Code
Substrate Condition
XRF
Reading (mg/cm2)
Color
East Side D M 5 0.01 Red
Basement, Weight Room Interior W C 2 0.001 White
Basement, Door to Toilet Room D W 1 0.00 Lt. Blue
Basement, Door to Toilet Room DC M 1 0.00 White
Basement, Toilet Room C C 1 0.00 White
Basement, Toilet Room Roof Drain P M 1 0.00 White
Basement, Shower Room C C 2 0.00 White
Basement, Hall from Bathroom DC M 1 0.00 White
Basement, Storage Cage BDE-S1 W C 1 0.00 White
Basement, Storage Cage BDE-S1 W C 1 0.00 White
Basement, Storage Cage BDE-S1 DC M 1 0.00 White
Basement, SE Stairs HR M 2 0.00 Lt. Blue
Basement, SE Stairs SR Vinyl 2 0.00 Grey
Basement, SE Hall /Storage Room W C 1 0.00 White
Basement, SE Hall /Storage Room C C 2 0.00 White
Basement, Boiler Room W CMU 1 0.00 White
Basement, Boiler Room W C 1 0.00 White
Basement, Boiler Room D M 2 0.00 Lt. Blue
Basement, Boiler Room DF M 3 0.00 White
Basement, Boiler Room WC M 2 0.00 Brown
Basement, Boiler Room C C 1 0.00 White
Basement, NW Stairs HR M 2 0.00 Lt. Blue
Basement, NW Stairs SR M 2 0.00 Lt. Blue
Basement, NW Stairs LW CMU 1 0.00 White
Basement, Former Pistol Range Ext. Wall C 1 0.00 White
Basement, Former Pistol Range Platform W 2 0.00 Grey
Basement, Former Pistol Range F C 2 0.00 Grey
Basement, Former Pistol Range C C 1 0.00 White
First Floor, NW Corner W C 1 0.00 White
First Floor, Break Room W CMU 1 0.00 White
BB-Baseboard; B-Bollards/Bumpers; C/T-Casing/Trim; CL-Ceiling; CR-Chair Rail; D-Door; DC-Door Casing; DJ-Door Jamb; DW-Duct Work; E-Equipment;
FL-Floor; HR- Handrail; HVAC-Fans/Air Handlers; M – Miscellaneous; P-Piping; R-Railing; RD-Radiator; RC-Radiator Cover; SB-Stair Balusters; SH- Shingles/Siding; SR-Stair Riser; SS-Stair Stringer; SR-Stair Railing; ST, Stair Tread; STC-Structural Column; STB-Structural Beam; STM-Structure Misc; W- Wall; UW-Upper Wall; LW-Lower Wall; WSH-Window Sash; WC-Window Casing; WSL-Window Sill
SUBSTRATE TYPE:
W-Wood; G-Gypsum Board; P-Plaster; C-Concrete; CB- Concrete Block; PA-Paneling: T-Tile; M-Metal; B-Brick; U-Unknown
PAINT CONDITION:
1 to 5; 1 = Undamaged (< 5% damage) ; 2 = Slight Damage (6-15% Damage) ; 3 = Moderate Damage (16-25% Damage) ;
4 = Extensive Damage (26-50% Damage) ; 5 = Severe Damage (>50% Damage)
XRF Lead Paint Testing Results Veterans Affairs Medical Center, Harwood Building, Providence, Rhode Island
Location Sample Code
Substrate Condition
XRF
Reading (mg/cm2)
Color
First Floor, Break Room WC M 1 0.00 Brown
First Floor, Break Room W CMU 1 0.00 White
First Floor, Break Room D M 2 0.00 Brown
Front Entryway CMU W 2 0.00 White
Hall at Room 200 HR M 1 0.00 Grey
Hall at Room 202/203 HR M 1 0.00 Grey
Room 203 RAD M 2 0.00 Grey
Room 204B W GB 1 0.00 Beige
Room 208 W CMU 2 0.00 White
Exterior West Side Window Grate M 1 0.00 Brown
South (Rear) D M 5 0.00 Red
South (Rear) Utility Shed W W 3 0.00 Red
South (Rear) Utility Shed Roof Sheets M 1 0.00 Green