This document is a comprehensive set of bid documents for the Fort Bliss National Cemetery Expansion project, a Department of Veterans Affairs capital improvement initiative located at 5200 Fred Wilson Avenue, El Paso, Texas (Project 886CM3026). The base bid package includes detailed architectural, structural, mechanical, plumbing, electrical, and technology drawings and specifications for three primary structures: an Admin Building, Maintenance Building, and PIC/Restroom Building.
The structural work encompasses concrete foundations and slabs designed for 1500 psf soil bearing pressure, concrete masonry unit (CMU) walls with bond beams, precast concrete lintels, structural steel connections, and building framing per AISC standards. All work must comply with PG-18-10 Structural Design Manual (VA approved), International Building Code 2024, ASCE/SEI 7-22, and VA Handbook H-18-8 seismic requirements (Seismic Design Category C, Risk Category II). Concrete compressive strengths range from 3000 psi to 5000 psi depending on application, with reinforcing steel lap splice schedules provided for Grade 60 bars. Mechanical systems include mini-split heat pump systems (Mitsubishi basis of design), rooftop units, swamp coolers with new water supply lines, louvers, and associated piping and ductwork with seismic bracing per ASCE 7-22 Chapter 13. Plumbing work involves new domestic hot water heating, fixture installation, drainage systems, and connections to existing water/sewer infrastructure. Electrical work includes new panelboards (Panel A 200A and Panel B 400A), branch circuit extensions, lighting fixtures, receptacles with GFI protection, and technology infrastructure with copper and fiber optic cabling, card readers, motion detectors, glass break sensors, and video surveillance cameras. Technology rough-in includes telecommunications outlets, cable tray/ladder rack systems, equipment racks, and intrusion detection systems. All MEP equipment anchorage and seismic bracing is designated as delegated design requiring sealed calculations from licensed professional engineers. The project documents include detailed demolition plans, foundation and floor construction details, shop drawing requirements, and schedules for fixtures and equipment with basis-of-design manufacturers specified throughout.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL COMPLY WITH THE PG-18-10 STRUCTURAL DESIGN
MANUAL DATED 7/1/2023 AS APPROVED BY THE DEPARTMENT OF
VETERANS AFFAIRS. THE FOLLOWING CODES APPLY:
-INTERNATIONAL BUILDING CODE 2024
-ASCE/SEI 7-22
-VA HANDBOOK H-18-8 SEISMIC DESIGN REQUIREMENTS
2. REFERENCE STANDARDS: UNLESS OTHERWISE NOTED (U.O.N.), ALL
STANDARDS SHALL BE CURRENT EDITION, WITH LATEST ADDENDA, IF
APPLICABLE.
3. THE CONTRACTOR SHALL VERIFY ALL CONTRACT DOCUMENTS, SITE
ELEVATIONS, DIMENSIONS AND CONDITIONS PRIOR TO STARTING WORK
AND SHALL NOTIFY THE ARCHITECT/ ENGINEER OF ANY DISCREPANCIES
OR INCONSISTENCIES.
4. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL
NOTES.
5. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS
REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE INDICATED,
THEY DO NOT INDICATE THE MEANS OR METHOD OF CONSTRUCTION.
TEMPORARY BRACING AND SHORING AGAINST WIND AND ERECTION
CONDITIONS DURING CONSTRUCTION OF THE BUILDING, SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS SOLELY
RESPONSIBLE FOR THE PROTECTION OF THE STRUCTURE DURING ALL
PHASES OF DEMOLITION, CONSTRUCTION, AND INSTALLATION.
6. NO AREA OF THE STRUCTURE SHALL BE LOADED WITH CONSTRUCTION
MATERIALS OR EQUIPMENT THAT EXCEEDS FINAL DESIGN CRITERIA.
7. VERIFY LOCATION OF BOX OUTS AND OPENINGS WITH MECHANICAL
CONTRACTORS. OPENING SIZES AND LOCATIONS SHOWN FOR PIPES,
DUCTS ETC. ARE FOR GENERAL INFORMATION ONLY AND SHALL BE
VERIFIED WITH THE MECHANICAL CONTRACTOR BEFORE COMMENCING
THE WORK.
8. IF MECHANICAL AND ELECTRICAL EQUIPMENT SIZES, WEIGHTS, OR
LOCATIONS DO NOT COINCIDE WITH EQUIPMENT SHOWN ON PLANS,
COORDINATE ADJUSTMENTS WITH THE STRUCTURAL ENGINEER.
9. HOLES, PIPES, SLEEVES, ETC. NOT SHOWN ON THE DRAWINGS MUST BE
APPROVED BY THE STRUCTURAL ENGINEER BEFORE PLACEMENT
THROUGH STRUCTURAL MEMBERS.
10. CONTRACTOR SHALL PROVIDE A CAST-IN SLEEVE FOR ALL HORIZONTAL
ELEMENTS THAT EXTEND THROUGH FOOTING. IE: DRAIN TILE, ELECTRICAL
CONDUIT, MECHANICAL PIPING, ETC. ALL SLEEVES SHALL BE
COORDINATED WITH ARCHITECT/ENGINEER.
11. SHOP DRAWINGS PREPARED BY SUPPLIERS, SUBCONTRACTORS, ETC.,
SHALL BE DIMENSIONED, REVIEWED, COORDINATED, AND SIGNED/
STAMPED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTING TO THE
STRUCTURAL ENGINEER.
12. FABRICATOR SHALL CLEARLY NOTE CHANGES MADE IN THE SHOP
DRAWINGS WHICH DO NOT COMPLY WITH THE CONTRACT DOCUMENTS.
REVIEWED APPROVAL SHOP DRAWINGS SHOWING ENGINEERS COMMENTS
ACCOMPANIED WITH RECORD SET SHOP SHOP DRAWINGS, SHALL BE
AVAILABLE FOR REFERENCE AT THE CONSTRUCTION SITE.
13. CONCRETE ANCHORS SHALL BE SIMPSON 'TITEN HD" SCREW ANCHORS OR
EQUIVALENT (U.O.N.). INSTALL ANCHORS USING THE MANUFACTURER'S
RECOMMENDATIONS.
FOUNDATION NOTES:
1. FOOTING ELEVATIONS ARE TO TOP OF FOOTING (T.O. FTG.), UNLESS
OTHERWISE NOTED.
2. FOOTINGS ARE DESIGNED FOR AN ASSUMED MINIMUM NET ALLOWABLE SOIL
BEARING PRESSURE OF 1500 psf. FOR CONTINUOUS AND PAD FOOTINGS.
THIS VALUE SHALL BE VERIFIED BY A GEOTECHNICAL ENGINEER, SUBMIT
REPORT OF OBSERVATION TO ARCHITECT/ENGINEER PRIOR TO POURING
FOOTINGS.
3. FOOTINGS SHALL BEAR ON NATURAL UNDISTURBED SOIL OR ENGINEERED
FILL. SOILS SHALL BE OBSERVED AND APPROVED BY A GEOTECHNICAL
ENGINEER PRIOR TO PLACEMENT OF FOOTING CONCRETE. IF NATURAL
UNDISTURBED SOILS ARE NOT ENCOUNTERED AND/OR INADEQUATE SOILS
ARE NOTED AT FOOTING BEARING LEVEL, ARCHITECT/ENGINEER SHALL BE
NOTIFIED PRIOR TO PROCEEDING WITH FURTHER WORK AT THOSE FOOTING
LOCATIONS.
4. PROTECT FOOTINGS FROM THE ACTION OF WATER OR FREEZING.
5. FOOTINGS ARE CENTERED UNDER WALLS ABOVE - UNLESS OTHERWISE
NOTED.
6. PRIOR TO PLACEMENT OF FOOTING CONCRETE, CLEAN FOOTING
EXCAVATIONS OF SNOW, WATER AND DEBRIS.
7. FOOTINGS MAY NOT BE EARTH FORMED.
EXCAVATION & BACKFILL NOTES:
1. EXCAVATION AND BACKFILL SHALL BE EXECUTED IN ACCORDANCE WITH THE
PROJECT SPECIFICATIONS.
2. BACKFILL, & COMPACTION SHALL BE INSPECTED AND CERTIFIED BY A LICENSED
GEOTECHNICAL ENGINEER. REPORTS ARE TO BE SUBMITTED TO THE
ARCHITECT/ ENGINEER.
3. FOOTING EXCAVATIONS SHALL BE EXCAVATED TO PROPER LINE AND LEVEL TO
ENSURE MINIMUM CONCRETE COVER OF FOOTING REINFORCEMENT FOR
FOOTING DEPTH.
4. BACKFILL SHALL BE COMPACTED BY MECHANICAL MEANS. FLOODING OR
WATER INUNDATION SHALL NOT BE PERMITTED.
5. BACKFILL SHALL BE PLACED IN ALTERNATING LIFTS ON EACH SIDE OF THE
FOUNDATION WALLS TO MAINTAIN STABILITY OF THE FOUNDATION WALLS.
6. BACKFILL SHALL NOT BE PLACED AGAINST BASEMENT FOUNDATION WALLS
UNLESS WALLS ARE ADEQUATELY BRACED TOP AND BOTTOM. FINAL WALL
BRACING IS BASEMENT SLAB OR ENGINEERED BACKFILL AND 1ST FLOOR
STRUCTURE. IF THESE ELEMENTS ARE NOT IN PLACE AT TIME OF BACKFILL,
CONTRACTOR SHALL PROVIDE AN ENGINEERED, TEMPORARY BRACING
SYSTEM. THE TEMPORARY BRACING SYSTEM PROPOSED SHALL BE SUBMITTED
TO THE ARCHITECT/ ENGINEER FOR REVIEW PRIOR TO BACKFILLING.
MASONRY NOTES:
1. CONCRETE BLOCK MASONRY UNITS SHALL CONFORM TO GRADE 'N', MOISTURE
CONTROLLED TYPE I REQUIREMENTS OF ASTM C90, WITH AN ASSUMED
COMPRESSIVE STRENGTH F'm - 2000 psi. MORTAR SHALL CONFORM TO ASTM
C270 AND SHALL BE TYPE 'M' OR TYPE 'S', WITH TYPE 'M' BELOW GRADE.
2. BOND BEAMS SHALL HAVE TWO CONTINUOUS #5 REINFORCING BARS. WHERE
SHOWN ON PLAN OR IN A DETAIL, PROVIDE A BOND BEAM AT THE TOP OF WALLS
AND SPACED NOT MORE THAN 10' - 0" ON CENTER VERTICALLY.
3. WIRE REINFORCING FOR CMU WALLS SHALL BE CORROSION RESISTANT 9 GA.
HORIZONTAL JOINT REINFORCING CONFORMING TO ASTM A951. WHERE BOND
BEAMS ARE REQUIRED TO BE SPACED MORE THAN 10' - 0" ON CENTER WIRE
REINFORCING SHALL BE INSTALLED AS PER MANUFACTURER'S
RECOMMENDATIONS WITH MAXIMUM SPACING OF 16" O.C. (U.O.N.).
4. CONCRETE GROUT FOR UNIT MASONRY CORES AND BOND BEAMS SHALL HAVE
A 28 DAY COMPRESSIVE STRENGTH OF 3000 psi.
5. MASONRY WALLS ARE TO BE SUPPORTED LATERALLY UNTIL THE ENTIRE ROOF
AND/OR FLOOR IS IN PLACE AS DETAILED.
6. MASONRY REINFORCING SHALL BE LAPPED AS FOLLOWS: #3 BAR = 18", #6 BAR
= 36", #4 BAR = 24", #7 BAR = 42", #5 BAR = 30", #8 BAR = 48".
7. VERTICAL REINFORCING BARS SHALL BE HELD IN POSITION AT TOP AND
BOTTOM AND AT 192 (REINF.) DIAMETER INTERVALS MAXIMUM. LENGTH OF
REINFORCING BARS TO BE COORDINATED WITH GENERAL CONTRACTOR AND
MASONRY CONTRACTOR.
8. WHERE CELLS ARE TO BE FILLED W/ CONCRETE GROUT, PROVIDE ADDITIONAL
FULL MORTAR BED AT CROSS WEBS ENCLOSING GROUTED CELL.
9. CONSOLIDATE ALL CONCRETE GROUT BY PUDDLING OR VIBRATING.
10. BLOCK COURSING SHOWN ON STRUCTURAL PLANS MAY NOT BE
REPRESENTATIVE OF ACTUAL COURSING. SEE ARCHITECTURAL PLANS AND
SECTIONS FOR ACTUAL LAYOUT OF BLOCK COURSING.
11. MASONRY PIERS SHALL BE LAID UP SIMULTANEOUSLY WITH WALLS AND SHALL
BE INTERLOCKED WITH WALL BLOCKS.
12. FIRST COURSE OF ALL HOLLOW MASONRY SHALL BE PLACED ON A FULL BED OF
MORTAR.
13. CAST DOWELS, WITH STANDARD HOOKS, IN FOOTINGS FOR PIERS AND WALLS
ABOVE. DOWELS SHALL BE THE SAME SIZE AND SPACING OF VERTICAL
REINFORCING. (U.O.N.)
14. INJECTION ADHESIVE SHALL BE SIMPSON "SET-XP" ADHESIVE OR APPROVED
EQUIVALENT (U.O.N.) USING THREADED RODS FOR INSTALL BASE MATERIAL
TEMPERATURES BETWEEN 50-110 DEGREES FARHENHEIT. SEE SPECIFICATION
FOR USAGE AND INSTALL ANCHORS IN STRUCTURAL CONFORMANCE WITH THE
MANUFACTURERS RECOMMENDATIONS.
CONCRETE NOTES:
1. CONCRETE CONSTRUCTION SHALL CONFORM TO AMERICAN CONCRETE
INSTITUTE (ACI) CODES AND SPECIFICATIONS, LATEST EDITION. ACI 301
"SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI 315 "DETAILS &
DETAILING OF CONCRETE REINFORCEMENT" ACI 318 "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE".
2. CONCRETE MIX DESIGN SHALL BE BY AN INDEPENDENT TESTING
LABORATORY.
3. CAST-IN-PLACE CONCRETE SHALL BE SUBJECT TO TESTING BY AN
INDEPENDENT TESTING LABORATORY. SEE PROJECT SPECIFICATIONS FOR
REQUIREMENTS.
4. NON WELDED REINFORCING STEEL SHALL BE GRADE 60 DEFORMED,
BILLET-STEEL, ASTM A615, U.O.N. ALL WELDED WIRE FABRIC (WWF) SHALL BE
PLAIN, ASTM A185.
5. WELDED REINFORCING STEEL SHALL BE GRADE 60, LOW CARBON, ASTM A706.
6. PROVIDE EXTRA REINFORCEMENT AROUND ALL OPENINGS GREATER THAN 12"
SQUARE OR 12" IN DIAMETER, INCLUDING DOOR OPENINGS, IN CONCRETE
WALLS & SLABS. PROVIDE 2 - #5 BARS @ 3" O.C., ON EACH SIDE OF THE
OPENING EXTENDING 24" BEYOND THE CORNER OF THE OPENING & 2 - #5
BARS AT 3" O.C. BY 3'-0" LONG DIAGONAL BARS AT EACH CORNER. PLACE
DIAGONAL BARS CENTERED ON CORNER @ 2" CLEAR OF CORNER. ADDITIONAL
REINFORCEMENT SHALL BE PROVIDED AT EACH LAYER OF REINFORCING.
7. REINFORCING STEEL SHALL BE BENT, SPLICED, AND PLACED IN ACCORDANCE
WITH THE ACI 301 (LATEST EDITION).
8. PROVIDE ADEQUATE SUPPORT BARS AND ACCESSORIES TO HOLD
REINFORCING BARS FIRMLY IN PLACE TO SPECIFIED COVERAGES.
9. CONTROL JOINTS SHALL BE PLACED IN A SQUARE PATTERN WITH A MAXIMUM
SPACING OF 10' - 0" O.C. FOR 4" THICK SLAB, 12' - 0" O.C. FOR 5" THICK SLAB, 15'
- 0" O.C. FOR 6" THICK SLAB. WHERE A SQUARE PATTERN IS NOT POSSIBLE,
THE MAXIMUM LONG SIDE TO SHORT SIDE OF THE JOINT PATTERN SHALL NOT
EXCEED A RATIO OF 1.5:1. CONSTRUCTION JOINTS SHALL BE LOCATED BY THE
CONTRACTOR AS REQUIRED FOR CONSTRUCTION WITH A MAXIMUM OF 3,000
SQUARE FEET.
10. CAST DOWELS, WITH STD 90 DEGREE HOOK, IN FOOTINGS FOR CONCRETE
PIERS AND WALLS ABOVE. DOWELS SHALL BE THE SAME SIZE AND NUMBER AS
THE VERTICAL REINFORCING. (U.O.N.)
11. CONCRETE MIX DESIGNS REQUIREMENTS: - AGGREGATES SHALL CONFORM
TO ASTM C33. - CONCRETE EXPOSED TO FREEZE THAW SHALL HAVE 4.5%-7.5%
AIR. - WATER/CEMENT RATIO 0.55 MAX. FOR FOOTINGS AND WALLS, 0.5 MAX.
FOR SLABS - NO FLY ASH IN EXPOSED SLABS, 0.25 MAX. FLY ASH/CEMENT
RATIO IN ALL OTHER APPLICATIONS - WATER PROOFING ADMIXTURE ADD FOR
EXTERIOR EXPOSED CONCRETE.
12 INJECTION ADHESIVE ANCHORS SHALL BE SIMPSON "SET-3G" OR APPROVED
EQUIVALENT (U.O.N.) USING STANDARD 36 KSI THREADED RODS (U.O.N.). SEE
SPECIFICATIONS FOR USAGE. INSTALL ANCHORS IN STRUCTURAL
CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
CAST-IN-PLACE CONCRETE COMPRESSIVE STRENGTHS
PIERS 5000 psi.
EXTERIOR SLABS ON GRADE (AIR ENTRAINED) 5000 psi.
REINFORCING CLEAR CONCRETE COVER
CONCRETE ON SOIL 3"
SLABS ON GRADE MIDHEIGHT
FORMED WALLS & STRUCTURAL SLABS EXPOSED TO EARTH OR
WEATHER: #6 THRU #18
2"
FORMED WALLS & STRUCTURAL SLABS EXPOSED TO EARTH OR
WEATHER: #5 OR SMALLER
1 1/2"
FORMED WALLS & STRUCTURAL SLABS NOT EXPOSED TO EARTH OR
WEATHER: #11 AND SMALLER
3/4"
BEAMS AND COLUMNS (COVER TO STIRRUPS OR TIES) 1 1/2"
CONC. REINFORCING BAR LAP SPLICE
SCHEDULE
BAR SIZE
f'c = 3000 psi.
f'c = 4000 psi.
f'c = 5000 psi.
CLASS
"B"
CLASS
"B"
CLASS
"B"
#3 22" 20" 18"
#4 30" 26" 22"
#5 36" 32" 28"
#6 44" 38" 34"
#7 64" 54" 50"
#8 72" 62" 56"
#9 82" 70" 64"
#10 92" 80" 70"
#11 102" 88" 78"
BAR LAP SCHEDULE NOTES:
A. REINFORCING BAR LAP SPLICE SCHEDULE APPLIES TO UNCOATED, GRADE 60
REINFORCING BAR NORMAL WEIGHT CONCRETE.
B. PROVIDE CLASS "B" LAP UNLESS OTHERWISE NOTED.
C. FOR EPOXY COATED BAR, MULTIPLY THE NOTED LENGTHS BY 1.5.
D. FOR LIGHT WEIGHT CONCRETE, MULTIPLY THE NOTED LENGTHS BY 1.3.
E. MAXIMUM SPACING OF BARS BEING LAPPED IS ONE FIFTH THE LAP SPLICE
LENGTH, NOT TO EXCEED 6".
F. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE
PLACED BELOW HORIZONTAL REINFORCEMENT.FOR TOP BARS, MULTIPLY THE
NOTED LENGTHS BY 1.3.
STRUCTURAL STEEL NOTES:
1. WELDED CONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE LATEST
RECOMMENDATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION
(AISC) AND THE AMERICAN WELDING SOCIETY (AWS).
2. COLUMN BASE AND CAP PLATES TO BE WELDED AROUND ALL SIDES.
3. WELDS NOT SPECIFIED SHALL BE A FILLET WELD, CONTINUOUS AND/OR ALL
AROUND WITH MINIMUM THROAT DIMENSION AS REQUIRED FOR MATERIAL
THICKNESS PER AWS.
4. STRUCTURAL FABRICATORS SHALL SHOW ALL FIELD WELDING REQUIREMENTS
ON SHOP DRAWINGS SUBMITTED TO THE ENGINEER.
5. BEFORE ENCASING STEEL COLUMNS IN CONCRETE OR MASONRY, COAT
COLUMN BASES AND TOPS OF ANCHOR BOLTS WITH ASPHALTIC ROOF
CEMENT.
6. BEAMS AND COLUMNS SHALL BE ERECTED TRUE AND PLUMB WITHIN AISC
TOLERANCE. PROVIDE TEMPORARY BRACING AS REQUIRED.
7. BEARING PLATES FOR STEEL SHALL BE DRY PACKED WITH A NON-SHRINK,
NON-METALLIC GROUT AS SPECIFIED.
8. PROVIDE DOUBLE ANGLE CONNECTIONS AS DESCRIBED IN PART 10 OF THE
AISC MANUAL OF STEEL CONSTRUCTION (15TH ED-ASD). CONNECTIONS SHALL
BE SELECTED TO SUPPORT BEAM END REACTIONS INDICATED ON THE
CONTRACT DRAWINGS. IF BEAM END REACTIONS ARE NOT INDICATED,
CONNECTIONS MUST BE SELECTED ACCORDING TO THE STANDARD DETAILS
OF THE CONTRACT DRAWINGS. IF BEAM IS NOT ABLE TO SATISFY THE
CONDITIONS OF THE STANDARD DETAILS CONTACT ENGINEER OF RECORD
FOR SPECIFIC DETAILING.
9. FRAMED STEEL BEAM CONNECTIONS SHALL BE "BEARING TYPE", (U.O.N.).
10. DO NOT PAINT STEEL TO BE FIELD WELDED.
AISC MATERIAL SPECIFICATION (13TH EDITION)
"W", "S" AND "M" SHAPES ASTM A992 Fy = 50 ksi.
GRADE "B" STANDARD PIPES ASTM A53 Fy = 35 ksi.
GRADE "C" HSS PIPES ASTM A500 Fy = 46 ksi.
GRADE "C" HSS TUBES ASTM A500 Fy = 50 ksi.
PLATES, BARS, CHANNELS, RODS, ANGLES AND
MISC. SHAPES
ASTM A36 Fy = 36 ksi.
GRADE 36 ANCHOR BOLTS ASTM F1554-99 Fy = 36 ksi.
CONNECTION BOLTS ASTM A325 Fv = 120 ksi.
CONNECTION BOLTS ASTM A490 Fv = 150 ksi.
CONNECTION NUTS ASTM A563
WASHERS ASTM F436
ELECTRODES E70XX
ABBREVIATIONS & SYMBOLS:
+/- PLUS OR MINUS
@ AT
A.B. ANCHOR BOLT
A.P.A. AMERICAN PLYWOOD
ASSOCIATION
A.S.T.M. AMERICAN SOCIETY OF TESTING
MATERIALS
ARCH. ARCHITECTURAL
B.B. BOND BEAM
B.O. BOTTOM OF
BLK. BLOCK
BM. BEAM
BOT. BOTTOM
BRG. BEARING
C CHANNEL
C.M.U. CONCRETE MASONRY UNIT
CCJ CONSTRUCTION CONTROL JOINT
CJ CONTROL JOINT
CL. CENTER LINE
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
D.L. DEAD LOAD
D.T. DOUBLE TEE / DRAIN TILE
DBL. DOUBLE
DIA. DIAMETER
DIM. DIMENSION
DWL. DOWEL
E.F. EACH FACE
E.J. EXPANSION JOINT
E.W. EACH WAY
EA. EACH
EL. ELEVATION
ELEV. ELEVATOR
EQ. EQUAL
EX. EXISTING
EXC. EXCAVATION
EXP. EXPANSION
F.D. FLOOR DRAIN
FDN. FOUNDATION
FT. FEET
FTG. FOOTING
G.C. GENERAL CONTRACTOR
G.T. GIRDER TRUSS
GA. GAUGE
GALV. GALVANIZE
HC. HOLLOWCORE
HORIZ. HORIZONTAL
HSS HOLLOW STRUCTURAL SECTION
I.F. INSIDE FACE
INT. INTERIOR
JST. JOIST
KLF. KIPS PER LINEAR FOOT
KSI. KIPS PER SQUARE INCH
L ANGLE
LB LEDGER BEAM
LL LIVE LOAD / DOUBLE ANGLE
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LWC LIGHT WEIGHT CONCRETE
M.C. MECHANICAL CONTRACTOR
MAS. MASONRY
MAX. MAXIMUM
MECH. MECHANICAL
MFG. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MTL. METAL
N. NORTH
N.T.S. NOT TO SCALE
NS. NON-SHRINK
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OUTSIDE FACE
O.H. OVERHEAD
OPNG. OPENING
ORIG. ORIGINAL
P.A.F. POWDER ACTUATED FASTENER
P.C. PRECAST CONCRETE
PART. PARTITION
PL. PLATE
PLF POUNDS PER LINEAR FOOT
PNL. PANEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PW PLYWOOD
R. OR
RAD.
RADIUS
R.D. ROOF DRAIN
REINF. REINFORCING
REQD. REQUIRED
S.A. STUD ANCHOR
S.B. SOIL BORING
S.D. SEE DETAIL
S.D.L. SUPERIMPOSED DEAD LOAD
S.E.R. STRUCTURAL ENGINEER OF
RECORD
S.L. SNOW LOAD
S.L.L. SUPERIMPOSED LIVE LOAD
S.S. STAINLESS STEEL
SCHED. SCHEDULE
SHT. SHEET
SIM. SIMILAR
SPA. SPACING / SPACES
SPECS. SPECIFICATIONS
SQ. SQUARE
STD. STANDARD
STL. STEEL
T & B TOP & BOTTOM
T & G TONGUE & GROOVE
T.O. TOP OF
T.O.B. TOP OF BEAM
T.O.J. TOP OF JOIST
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
T.S.E. TOP OF STEEL ELEVATION
TEMP. TEMPORARY
THK. THICK / THICKENED
TRANS. TRANSVERSE
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V. / VER. VERIFY
VERT. VERTICAL
W.L. WIND LOAD
W/ WITH
W/O WITH OUT
WD. WOOD
WTS. WEIGHTS
WWF WELDED WIRE FABRIC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
886CM3026FT BLISS NATIONAL
CEMETERY EXPANSION
18528
5200 FRED WILSON AVENUE, EL PASO, TEXAS
JUNE 15, 2026
C U s e rs \J
B u e rm a n n
\D o c u m e n ts
\1
-P
IC
R E
S T
R O
O M
-S -R
V T jb u e rm a n n S
R X
R
.r v t
/1
/2
:0
:1
P
M
S-001
NOTE SHEET
JUNE 15, 2026 EW DW
INTERSTORY DRIFT LIMIT 0.020*H
SEISMIC DESIGN CATEGORY C
SITE CLASS D
DESIGN SPECTRAL RESPONSE Sd1 = 0.2 DESIGN SPECTRAL RESPONSE Sds = 0.35
MAPPED SPECTRAL RESPONSE S1 = 0.11
MAPPED SPECTRAL RESPONSE Ss = 0.39 SEISMIC IMPORTANT FACTOR le = 1
RISK CATEGORY II
LATERAL LOADS
(SEISMIC - MSFRS)
COMPONENTS CLADDING BASE... 24.0 psf.
INTERNAL PRESSURE COEFF +/- 0.18
WIND EXPOSURE "C"
RISK CATEGORY II
NOMICAL WIND SPEED 81.3 MPH.
ULTIMATE WIND SPEE (3 SECOND GUST) 105 MPH.
IMPORTANCE FACTOR 1.0 lw
LATERAL LOADS (WIND -
MSFRS)
TYPICAL ROOF DL = 20 psf.
DEAD LOADS:
LIVE LOAD 20 psf.
CONSTRUCTION LOADING 25 psf.
GROUND SNOW LOAD Pg = 15 psf.
THERMAL FACTOR Ct = 1.2 EXPOSURE FACTOR Ce = 1.0 IMPORTANCE FACTOR ls = 1.0 ROOF SNOW Pf=13 psf.
ROOF LIVE LOADS:
16. DESIGN LOADS:
DEFERRED SUBMITTAL SCHEDULE:
SUPPORT/ANCHORAGE FOR MECHANICAL
ELECTRICAL, PLUMBING EQUIPMENT AND THEIR COMPONENTS
FIRE SPRINKLER SEISMIC BRACING
DEFERRED SUBMITTAL SCHEDULE NOTES:
1. PREFABRICATED COMPONENTS OR SYSTEMS SPECIFIED ON THE STRUCTURAL
DRAWINGS TO BE DESIGNED BY OTHERS SHALL BE SUBMITTED BY THE
CONTRACTOR TO THE ARCHITECT OR ENGINEER OF RECORD FOR REVIEW AS A
DEFERRED SUBMITTAL. DEFERRED SUBMITTALS SHALL INCLUDE DRAWINGS
AND CALCULATIONS THAT HAVE BEEN STAMPED AND SIGNED BY AN ENGINEER
APPROPRIATELY LICENSED IN THE STATE OF CONSTRUCTION.
2. THE PURPOSE OF THE ENGINEER OF RECORD’S REVIEW SHALL BE
DETERMINING THAT THE DRAWINGS AND CALCULATIONS HAVE BEEN PROPERLY
SEALED, THAT THE LOAD CRITERIA IS IN GENERAL CONFORMANCE WITH THE
CONTRACT DOCUMENTS AND THE REFERENCED BUILDING CODE, AND THAT THE
CONNECTIONS TO THE PRIMARY STRUCTURE ARE APPROPRIATE FOR THE
STRUCTURE’S DESIGNED CAPABILITIES.
3. THE STRUCTURAL ENGINEER WILL RELY ON THE SPECIALTY ENGINEER’S SEAL
AS CERTIFICATION THAT THE ITEMS DESIGNED BY THE SPECIALTY ENGINEER
COMPLY WITH THE CRITERIA SET FORTH IN THE CONTRACT DOCUMENTS AND
APPLICABLE CODES AND STANDARDS. THE STRUCTURAL ENGINEER SHALL NOT
BE RESPONSIBLE FOR THE ADEQUACY OF DESIGNS PROVIDED BY OTHERS.
4. MECHANICAL, ELECTRICAL, AND PLUMBING (MEP) EQUIPMENT ANCHORAGE AND
BRACING IS A DELEGATED DESIGN. CONTRACTOR SHALL PROVIDE SHOP
DRAWINGS AND CALCULATIONS PREPARED BY A LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF CONSTRUCTION. DESIGN SHALL CONFORM TO
ASCE 7-22 CHAPTER 13. PROVIDE ISOLATORS, FASTENERS, AND BRACING THAT
ARE ICC-ES APPROVED AND CAPABLE OF TRANSFERRING ALL CODE-REQUIRED
LATERAL LOADS. SUSPENDED EQUIPMENT SHALL BE LATERALLY BRACED TO
THE MAIN STRUCTURE.
5 PIPING AND DUCTWORK SEISMIC BRACING IS A DELEGATED DESIGN.
CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND CALCULATIONS
PREPARED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF
CONSTRUCTION. DESIGN SHALL CONFORM TO ASCE 7-22 CHAPTER 13. BRACING
DETAILS MAY FOLLOW SMACNA 'GUIDELINES FOR SEISMIC RESTRAINTS OF
MECHANICAL SYSTEMS' PROVIDED THEY MEET MINIMUM LATERAL FORCE
REQUIREMENTS OF ASCE 7-22.
6 FIRE SPRINKLERS SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH ASCE
7-22 CHAPTER 13 AND NFPA 13. SEISMIC BRACING CALCULATIONS AND SHOP
DRAWINGS SHALL BE PROVIDED AS A DELEGATED DESIGN, PREPARED AND
STAMPED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE
OF CONSTRUCTION.
Revisions: Date: 106 of 155
BASE BID
L1
L2
OPEN
VER.
8' - 0 1/8"
VER.
5' - 0 1/4"
VER.
7' - 2 3/8"
V E
R
6'
3/
4"
V E
R
/8
(E) 2x6
(E) PCL
(E) PCL
(E
P C
L
V E
R
2'
3/
4"
(E) 2x6
(E) 2x6
T.O. (E) C.M.U
EL.=110'-8" (VER.)
(E) 6x6 POST
ABOVE
(E) LOUVER IN WALL
(E) 3"x6"
(E ) 3
"x 6"
(E ) 3
"x 6"
(E) 3"x6"
(E ) 2 x1 2(E) 2x12
(E) 3"x6" (E ) 3
"x6
North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
886CM3026FT BLISS NATIONAL
CEMETERY EXPANSION
18528
5200 FRED WILSON AVENUE, EL PASO, TEXAS
JUNE 15, 2026
C U s e rs \J
B u e rm a n n
\D o c u m e n ts
\1
-P
IC
R E
S T
R O
O M
-S -R
V T jb u e rm a n n S
R X
R
.r v t
/1
/2
:0
:1
P
M
3004-S-201
PIC/RESTROOM BLDG - LOWER AND UPPER
ROOF FRAMING PLAN
JUNE 15, 2026 EW DW
KEYNOTES:
1 INFILL EXISTING OPENING WITH 8" C.M.U.
GROUTED AND REINFORCED WITH #5 VERT.
PROVIDE NEW STEEL LINTEL. - S.D. 1/3004-S-401
2 INFILL EXISTING OPENING WITH 8" C.M.U.
GROUTED AND REINFORCED WITH #5 VERT. @
1'-4" O.C. - S.D. 2/3004-S-401
1. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
2. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
3. L# = LINTEL MARK - SEE LINTEL SCHEDULE ON THIS SHEET.
4. (E) PCL = EXISTING PRECAST CONCRETE LINTEL
SHEET NOTES:
1/4" = 1'-0"
LOWER ROOF FRAMING PLAN
1/4" = 1'-0"
UPPER ROOF FRAMING PLAN
North
LINTEL SCHEDULE
MARK LINTEL REINFORCEMENT COMMENTS
L1 PL. 7.5" x 1 1/2" - S.D. 1/3004 - S-401
L2 (E) PCL - S.D. 2/3004 - S-401
Revisions: Date: 107 of 155
(E) BOND BEAM W/ (1) #4 BAR CONT.
(E) LOUVER (VER.)
(E) 2-#4 JAMB BARS (GROUTED SOLID)
(E) 4-#4 FULL HEIGHT BARS, 2 PER CELL (GROUTED SOLID)
(E) 8" CMU W/ #4 BAR @ 2'-0" O.C.
(E) CMU WALL BEYOND
(E) BOND BEAM W/ (1) #4 BAR CONT.
(E) LOUVER (VER.)
(E) 4-#4 FULL HEIGHT BARS, 2
PER CELL (GROUTED SOLID)
(E) 8" CMU W/ #4 BAR @ 2'-0" O.C.
(E) CMU WALL BEYOND
GROUT BLOCK ABOVE
NEW STEEL LINTEL SOLID
NEW STEEL LINTEL - SEE PLAN
FINISHED FLOOR
EL. = 100'-0" VER.
T.O. FOOTING
EL. = 98'-0" (VER.)
(E) PCL (7-5/8"Wx7-5/8"H, REINF. W/ 2-#3 TOP & 2-#5 BOT
(E) PCL (7-5/8"Wx7-5/8"H, REINF. W/ 2-#3 TOP & 2-#5 BOT
FINISHED FLOOR
EL. = 100'-0"
T.O. FOOTING
EL. = 98'-0" (VER.)
(E) CONC. FTG.
(E) CMU WALL BEYOND(E) CMU WALL BEYOND
T.O. WALL
EL. = 110'-8" (VER.)
T.O. WALL
EL. = 110'-8" (VER.)
EXISTING CONDITION NEW CONDITION
6 3/4" 7 5/8"
3' - 2 1/4" 2' - 8"
2'
0" 4'
8"
1/2" PL. BOLTED WITH 3/8" DIA. SIMPSON
"TITEN HD" SCREW ANCHORS OR
APPROVED EQUIVALENT (U.O.N.) @ 1'-0"
O.C - ROWS STAGGERED - EMBED 4" MIN.
6 3/4"
3' - 4"
7'
1/
2"
2' - 6 1/4"
A
A
SECTION A
WALL
(E) 8" CMU
GROUT BLOCK ABOVE
STEEL LINTEL SOLID.
3/8" DIA. SIMPSON "TITEN HD"
SCREW ANCHORS OR
APPROVED EQUIVALENT
(U.O.N.) @ 1'-0" O.C - ROWS
STAGGERED - EMBED 4" MIN.
STEEL LINTEL 7.5"x1.5"
FY MIN = 50 KSI
NOTE:
1. FIELD VERIFY ALL EXISTING CONDITIONS
NOTE:
1. VERIFY ALL DIMENSIONS @ NEW CONDITION WITH
ARCHITECTURAL DRAWINGS.
3/16
(E) BOND BEAM W/ (1) #4 BAR CONT.
(E) 8" CMU W/ #4 BAR @ 2'-0" O.C.
(E) CMU WALL BEYOND
(E) PCL (7-5/8"Wx7-5/8"H, REINF. W/ 2-#3 TOP & 2-#5 BOT
FINISHED FLOOR
EL. = 100'-0"
T.O. FOOTING
EL. = 98'-0" (VER.)
(E) CONC. FTG.
(E) CMU WALL BEYOND
T.O. WALL
EL. = 110'-8" (VER.)
EXISTING CONDITION
NEW CONDITION
3' - 4"
8" 1' - 11"
(E) BOND BEAM W/ (1) #4 BAR CONT.
(E) 8" CMU W/ #4 BAR @ 2'-0" O.C.
(E) CMU WALL BEYOND
(E) PCL (7-5/8"Wx7-5/8"H, REINF. W/ 2-#3 TOP & 2-#5 BOT
FINISHED FLOOR
EL. = 100'-0"
T.O. FOOTING
EL. = 98'-0" (VER.)
(E) CONC. FTG.
(E) CMU WALL BEYOND
T.O. WALL
EL. = 110'-8" (VER.)
2' - 8"
8" 1' - 11"
2'
0" 4'
0"
BOND BEAM WITH 2-#5 CONT.
DRILL+EPOXY #5 BAR INTO (E) CMU
WALL EMBED = 4"
INFILL EXISTING OPENING WITH 8"
C.M.U. GROUTED AND REINFORCED
WITH #5 VERT. @ 1'-4" O.C.
DRILL+EPOXY #5 BAR INTO (E) FTG W/
SIMPSON "SET-3G" EPOXY OR
APPROVED EQUIVALENT (U.O.N.) -
EMBED = 8" MIN. - SEE NOTE 2
DRILL+EPOXY #5 BAR
INTO (E) PCL W/
SIMPSON "SET-3G"
EPOXY OR APPROVED
EQUIVALENT (U.O.N.) -
EMBED = 4" MIN.
8'
8"
INFILL EXISTING OPENING WITH 8"
C.M.U. GROUTED AND REINFORCED
WITH #5 VERT. @ 1'-4" O.C.
NOTE:
1. VERIFY ALL DIMENSIONS @ NEW CONDITION WITH ARCHITECTURAL
DRAWINGS.
2. FIELD VERIFY IF THE EXISTING C.M.U. WALL IS GROUTED SOLID AT
FINISHED FLOOR ELEVATION. IF THE EXISTING C.M.U WALL IS GROUTED
SOLID AT THIS ELEVATION, THEN DRILL+EPOXY #5 BAR INTO TOP OF (E)
C.M.U. WALL W/ SIMPSON "SET-3G" EPOXY OR APPROVED EQUIVALENT
(U.O.N.) - EMBED =8" MIN.
NOTE:
1. FIELD VERIFY ALL EXISTING CONDITIONS.
EXISTING CMU CORES SHALL BE
GROUTED SOLID AFTER INSTALLING
REBAR IF CORES ARE NOT
ALREADY GROUTED SOLID
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
886CM3026FT BLISS NATIONAL
CEMETERY EXPANSION
18528
5200 FRED WILSON AVENUE, EL PASO, TEXAS
JUNE 15, 2026
C U s e rs \J
B u e rm a n n
\D o c u m e n ts
\1
-P
IC
R E
S T
R O
O M
-S -R
V T jb u e rm a n n S
R X
R
.r v t
/1
/2
:0
:1
P
M
3004-S-401
PIC/RESTROOM BLDG - FRAMING DETAILS
JUNE 15, 2026 EW DW
1/2" = 1'-0"3004-S-401
1 CMU INFILL & LINTEL @ (E) WALL DETAIL
1/2" = 1'-0"3004-S-401
2 CMU INFILL (E) WALL DETAIL
Revisions: Date: 108 of 155
(E) 26K5
(E) 26K5
(E) 26K5
(E) 26K5
(E) 26K5
(E) 26K5
(E) 26K5
(E) 26K5
(E) 26K5
(E) 20K6
(E
2x
(E
2x
(E
2x
L1
(E) 10K1 (E) 10K1
(E
W x1
(E) 10K1(E) 16K3
(E
6x
(E
2x
(E
2x
(E
2x
(E ) C
OL.
(E ) C
OL.
W 6x
(E) 2x8
W 6x
(E ) C
OL
(E ) C
OL.
(E ) C
OL.
(E ) C
OL.
(E) 4 - 2x12
(E
2x
(E)HSS8x8x1/4
(E )H
S S
8x 8x
1/
(E
2x
(E
2x
(E
2x
(E
2x
(E) 16x36
(E) 20K6
(E) 16x31
(E) 16K3
3003-S-201
3003-S-201
3003-S-201
C.M.U. WALL (VERIFY)
EXISTING 12"
STEEL LINTEL @ C.M.U.
SEE PLAN
NOTE: ALL LINTELS AND VENEER LINTELS TO HAVE 8" BEARING MINIMUM @ EACH END.
L4x3 1/2x1/4 (LLV)
VENEER LINTEL
EXISTING SPLIT
FACE BLOCK
NOTE:
PROVIDE SIMILAR CORNER BARS AT MASONRY WALL INTERSECTIONS.
4 CORNER BAR @
EACH BOND BEAM
REINFORCING BAR
SEE PLAN
C.M.U. WALL
NOTES:
1. LAY UP WALL 4'-0" HIGH & PLACE REINFORCING BARS.
2. FILL CELLS WITH CONCRETE @ REBAR LOCATIONS ONLY (UNLESS OTHERWISE
NOTED ON PLAN FOR ADDITIONAL GROUTING) - PUDDLE OR VIBRATE TO
CONSOLIDATE.
3. REPEAT PROCEDURES ABOVE FOR ENTIRE HEIGHT OF WALL.
4. SEE GENERAL STRUCTURAL NOTES FOR TENSION SPLICE REQUIREMENTS.
SINGLE LAYER DOUBLE LAYER
CENTER REINF.
BAR IN CELL
CONSTRUCTION
JOINT LEVEL IN
GROUTED CELL
C.M.U. WALL
SEE PLAN
2"
1" CLR. 1" CLR.
C.M.U. WALL
SEE PLAN
C.M.U. WALL
SEE PLAN
3/16
EXISTING HSS8x8 STEEL BEAM
INFILL W/8" C.M.U.GROUTED AND REINFORCED
W/# 4 VERTICAL BARS @ 2'-0" O.C. TO MATCH
@ EA. EXISTING BAR & #4 HORIZONTAL BARS
@ 2'-0" O.C. REMOVE FACESHELL TO INSTALL
REINFORCMENT AND GROUT
EXISTING 8"
C.M.U. WALL
EXISTING 8"
C.M.U. WALL
DRILL & EPOXY EA. #4 WITH
SIMPSON "SET-3G" EPOXY OR APPROVED
EQUIVALENT (U.O.N.)
EMBED = 8"
E M
B E
D
North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
886CM3026FT BLISS NATIONAL
CEMETERY EXPANSION
18528
5200 FRED WILSON AVENUE, EL PASO, TEXAS
JUNE 15, 2026
C U s e rs \J
B u e rm a n n
\D o c u m e n ts
\1
-M
A
IN
T -S
-R V
T jb u e rm a n n S
R X
R
.r v t
/1
/2
:3
:4
A
M
3003-S-201
MAINTENANCE BLDG - ROOF FRAMING PLAN
JUNE 15, 2026 EW DW
KEYNOTES:
1 INFILL WITH 8" CMU GROUTED AND REINFORCED WITH #4
VERTICAL BARS @ 2'-0" O.C. TO MATCH @ EA. EXISTING BAR & #4
HORIZONTAL BARS @ 2'-0" O.C. - REMOVE FACESHELL TO INSTALL
REINFORCEMENT AND GROUT - S.D. 4/S3003-S-201
2 DRILL + EPOXY EACH #4 HORIZONTAL BAR INTO EXISITING 8" CMU
WALL WITH SIMPSON "SET 3G" EPOXY OR APPROVED EQUIVALENT
(U.O.N.) - EMBED = 8"
1. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
2. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
3. L# = LINTEL MARK - SEE LINTEL SCHEDULE ON THIS SHEET.
SHEET NOTES:
1/4" = 1'-0"
ROOF FRAMING PLAN
LINTEL SCHEDULE
MARK LINTEL REINFORCEMENT COMMENTS
L1 2 - L 5 x 5 x 5/16 - S.D. 1/3003-S-201
1" = 1'-0"3003-S-201
1 LINTEL @ EXISTING C.M.U. WALL DETAIL
1" = 1'-0"3003-S-201
3 C.M.U. CORNER REINFORCING DETAIL
1" = 1'-0"3003-S-201
2 C.M.U. WALL REINFORCING DETAIL
1" = 1'-0"3003-S-201
4 C.M.U INFILL DETAIL
Revisions: Date: 109 of 155
6" CONC. SLAB, REINF. W/ #4 @ 1'-6" EACH WAY, ON 6"
SAND FILL
T.O. SLAB EL. = 100'-0" U.O.N.
6"6" 12' - 0"
13' - 0"
6" 6"
6"
6"
6"
6"
(E ) C
OL
CONC.
PIE
R
(E ) C
OL
CONC.
PIE
R
(E) COL &
CONC.
PIER
(E ) C
OL
CONC.
PIE
R
CONTROL JOINT-TYP.
6" 6"
SLAB ON GRADE
SEE PLAN "A"
3/16" SAW CUT OR TOOL JOINT
IN EXPOSED SLAB. FILL WITH
POURABLE SEALANT
4"
3/4" DIA. X 1'- 1" SMOOTH DOWEL
@ 1'-0" O.C. GREASE ONE END.
NOTE:
DIM. "A" = 1" FOR 4" SLABS, 1 1/4" FOR 5" SLABS, & 1 1/2" FOR 6" SLABS
NOTE:
SAW CUT SHALL BE EXECUTED AS SOON AS CONCRETE HAS HARDENED
SUFFICIENTLY TO PREVENT AGGREGATE DISLODGING BY SAW & PRIOR
TO SHRINKAGE STRESS CRACKING.
SLAB ON GRADE
SEE PLAN
1/4 SLAB DEPTH
3/16" SAW CUT OR TOOL
JOINT IN EXPOSED SLAB
CONSTRUCTION
OR CONTROL
JOINT TYP.
SLAB ON GRADE
SEE PLAN
EXISTING C.I.P COLUMN
BOND BREAK
EXISTING C.I.P. COLUMN
GRID
GRID
6"
North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
886CM3026FT BLISS NATIONAL
CEMETERY EXPANSION
18528
5200 FRED WILSON AVENUE, EL PASO, TEXAS
JUNE 15, 2026
C U s e rs \J
B u e rm a n n \D o c u m e n ts \1
-H G
-S -R
V T jb u e rm a n n S
R X
R
.r v t
/1
/2
:4
:0
A
M
3302-S-101
HONOR GUARD SHELTER - FOOTING &
FOUNDATION PLAN
JUNE 15, 2026 EW DW
3/8" = 1'-0"
FOOTING & FOUNDATION PLAN
1/2" = 1'-0"3302-S-101
1 FLOOR CONSTRUCTION JOINT DETAIL
1/2" = 1'-0"3302-S-101
2 FLOOR CONTROL JOINT DETAIL
1/2" = 1'-0"3302-S-101
3 COLUMN ISOLATION JOINT DETAIL
Revisions: Date:
SHEET NOTES:
1. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
2. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
3. THE COLOR OF THE NEW CONCRETE SLAB AT HONOR GUARD SHELTER
SHALL MATCH EXISTING. REFER TO ARCHITECTURAL DRAWINGS AND
03 30 53 SPECIFICATION.
T.O. PIER
EL. = FINISHED
GRADE (VERIFY)
9" CONC. SLAB, REINF. W/ #4 T&B @ 0'-5" O.C. EACH
WAY, ON 6" SAND FILL
CONTROL JOINT - TYP.
CENTER HIGH POINT - SEE SHEET NOTE #3
4001-S-101
4001-S-101
4001-S-101
1 1 1 1 1 1 P1 P1 P1 P1 P1 P1
NOTE:
SAW CUT SHALL BE EXECUTED AS SOON AS CONCRETE HAS HARDENED
SUFFICIENTLY TO PREVENT AGGREGATE DISLODGING BY SAW & PRIOR
TO SHRINKAGE STRESS CRACKING.
SLAB ON GRADE
SEE PLAN
1/4 SLAB DEPTH
3/16" SAW CUT OR TOOL
JOINT IN EXPOSED SLAB
MARK P1
6 - #5 VERTS. W/
#3 TIES @ 1'-0" O.C.
U.O.N.
3" CLR.
SEE PLAN FOR
SIZE & REINF.
9" L
AP
1' - 6"
1 3/4" DIA. STEEL
POST - SEE ARCH
1' - 6" EMBED
CONCRETE SURROUND -
SLOPE AWAY FROM
POST AT 1/4"/FOOT
3' -0
M
IN
NOTE:
ALL SIX MILITARY SEAL POST ELEVATIONS SHALL MATCH.
DRILL & EPOXY #4 DWLS TO
MATCH SLAB ON GRADE REINF.
EMBED = 1'-8"
EXISTING FDN. WALL
VERIFY
EXISTING GRANITE
SLAB ON GRADE
SEE PLAN
2" CLR.
2" CLR.
EXISTING FOOTING
VERIFY
EMBED
BOND BREAK
6" 6"
SLAB ON GRADE
SEE PLAN "A"
3/16" SAW CUT OR TOOL JOINT
IN EXPOSED SLAB. FILL WITH
POURABLE SEALANT
4"
3/4" DIA. X 1'- 1" SMOOTH DOWEL
@ 1'-0" O.C. GREASE ONE END.
NOTE:
DIM. "A" = 1" FOR 4" SLABS, 1 1/4" FOR 5" SLABS, & 1 1/2" FOR 6" SLABS
North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
L0W VOLTAGE/SECURITY:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
PETE MCGHEE
IRRIGATION:
AQUA ENGINEERING
300 BOARDWALK DRIVE
UNIT 4B
FORT COLLINS,CO 80525
970.372.6104
JD LEONARD
GEOTECHNICAL:
TERRACON
6460 HILLER STREET
SUITE A
EL PASO, TX 79925
915.778.5233
IVAN AVELAR
FIRE ALARM:
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309.781.3770
MATT SNYDER
886CM3026FT BLISS NATIONAL
CEMETERY EXPANSION
18528
5200 FRED WILSON AVENUE, EL PASO, TEXAS
JUNE 15, 2026
C U s e rs \J
B u e rm a n n
\D o c u m e n ts
\1
-R O
S T
R U
M -S
-R V
T jb u e rm a n n S
R X
R
.r v t
/1
/2
:5
:1
A
M
4001-S-101
ROSTRUM - FOOTING & FOUNDATION PLAN
JUNE 15, 2026 EW DW
KEYNOTES:
1 COORDINATE FINAL LOCATION OF MILITARY
SEALS WITH 4101-AE111.
1. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
2. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
3. NEW 9" CONCRETE SLAB SHALL SLOPE UNIFORMLY FROM CENTER HIGH
POINT TO PERIMETER AT A RANGE OF 1/8"-1/4" PER FOOT TO PROVIDE
POSITIVE DRAINAGE.
4. THE COLOR OF THE NEW CONCRETE SLAB AT ROSTRUM SHALL MATCH
EXISTING. REFER TO ARCHITECTURAL DRAWINGS AND 03 30 53
SPECIFICATION.
5. EXISTING FOUNDATION WALL SHALL BE BRACED AT THE EXTERIOR FACE
OF THE FOUNDATION WALL PRIOR TO DEMOLITION OF THE EXISTING
SLAB-ON-GRADE TO MAINTAIN WALL STABILITY DURING CONSTRUCTION.
SHEET NOTES:
1/4" = 1'-0"
FOOTING & FOUNDATION PLAN
1/2" = 1'-0"4001-S-101
2 FLOOR CONTROL JOINT DETAIL
1/2" = 1'-0"4001-S-101
4 MILITARY SEAL STEEL POST @ EXT. PIER DETAIL
1/2" = 1'-0"4001-S-101
3 SLAB CONN. DETAIL
Revisions: Date:
Schedule Notes - Pier
MARK PIER SIZE COMMENTS
P1 1'-6" DIA. S.D. 4/4001-S-101
1/2" = 1'-0"4001-S-101
1 FLOOR CONSTRUCTION JOINT DETAIL
B
M
D
Ƨ
Ƨ
M
S
S
M
CO2
CO
H2
HZG
NO2
O2
HS
H
T
TC
TH
TS
T/P
M
S
T/P
EM
TP
W
IR
S
CHWS
CD
CDR
CWR
CWS
HWR
HWS
G
STM
(E)
CHWR Chilled-Water Return
Chilled-Water Supply
Condensate Drain
Steam Condensate Return
Condenser-Water Return
Condenser-Water Supply
Hot-Water Return
Hot-Water Supply
Natural Gas
Steam Supply
RL
RS
Refrigerant Liquid
Refrigerant Gas
2"
RD Refrigerant Discharge
Mechanical Piping Symbols
Keynote Symbol
Continuation Symbol
Sheet Number Where Detail is Placed
Detail Number on Sheet
Plan Revision Number
General Plan Symbols
Room Name / Number
Point Where New Connects To Existing
Existing Pipe To Remain
Area Being Demolished
Area Not In Contract
Pipe To Be Demolished
Above Ground Piping
Nominal Pipe Size
Below Ground Piping
Pipe Slope (When Applicable)
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN
THIS SET.THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
LP Liquid Propane
1/8" / 12" SLOPE
24"x12"
24"/12"
18"Ø
General Exhaust Air
Outdoor Air
Building Relief Air
Return Air
Supply Air
Transfer Air
Grille, Register, Diffusers
Airflow
Catalog Throw Performance Neck Size / Module Size
Existing Duct To Remain
Oval Duct Size (Width / Height)
Sq. Duct Size (Width x Height)
HVAC Symbols
Rect. Supply Duct Rise / Drop
Mechanical Equipment
Round Duct Size (Diameter)
Duct To Be Demolished
Kitchen Exhaust Duct
Env. Tobacco Smoke
Equipment By Others (Refer To Other Disciplines)
Existing to Remain Equipment
Flue Gas Vent
Combustion Air
Ventilation Air
(E)AHU-2
Ø ROUND
ABV ABOVE
AC AIR CONDITIONING
AD AREA DRAIN
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
AFUE ANNUAL FUEL UTILIZATION EFFICIENCY
ALT ALTERNATE
AP ACCESS PANEL
ARCH ARCHITECT/ARCHITECTURAL
BFF BELOW FINISHED FLOOR
BLW BELOW
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER HOUR
CAP CAPACITY
CB CATCH BASIN
CFM CUBIC FEET PER MINUTE
CLG CEILING
CO CLEAN OUT
CW COLD WATER
D DEGREE
DB DRY BULB
DIA DIAMETER
DN DOWN
DW DISTILLED WATER
EA EACH
EAT ENTERING AIR TEMPERATURE
ELEC ELECTRICAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
E/A EXHAUST AIR
EXIST EXISTING
F DEGREES FAHRENHEIT
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FL FLOOR
FO FUEL OIL
FOV FUEL OIL VENT
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FPM FEET PER MINUTE
FS FLOOR SINK
FT FOOT/FEET
FTR FIN TUBE RADIATION
GAL GALLON
GF GAS-FIRED
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
GW GREASE WASTE
HB HOSE BIB
HP HORSE POWER
HTG HEATING
HTR HEATER
HW HOT WATER
HYD HYDRANT
ID INDIRECT
IN INCH
INV INVERT
LB POUND
LB/HR POUNDS PER HOUR
LAT LEAVING AIR TEMPERATURE
LP LOW PRESSURE
LPG LIQUEFIED PETROLEUM GAS
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M/A MIXED AIR
MAX MAXIMUM
MBH ONE THOUSAND BTU PER HOUR
MCF ONE THOUSAND CUBIC FEET
MD MOTORIZED DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTR MOTOR
MU/A MAKE-UP/AIR
NC NOISE CRITERIA
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NUMBER
NO NORMALLY OPEN
NTS NOT TO SCALE
O OXYGEN
O/A OUTSIDE AIR
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP
PIV POST INDICATOR VALVE
PLBG PLUMBING
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PWR POWER
R DUCT RISER
R/A RETURN AIR
RCP RADIANT CEILING PANEL
RD ROOF DRAIN
REC RECESSED
RED REDUCER
RH RELATIVE HUMIDITY
RL/A RELIEF AIR
RM ROOM
RPM REVOLUTIONS PER MINUTE
RW RAIN WATER
SF SQUARE FOOT
S/A SUPPLY AIR
SAN SANITARY
SF SQUARE FOOT
SD SMOKE DAMPER
SM SURFACE MOUNT
SP STANDPIPE
SP STATIC PRESSURE
STM STEAM
T THERMOSTAT
TD TEMPERATURE DROP
TDR TRENCH DRAIN
TEMP TEMPERATURE
TYP TYPICAL
UG UNDERGROUND
VAC VACUUM
V VENT
VAV VARIABLE AIR VOLUME
VENT VENTILATION
VTR VENT THROUGH ROOF
W WASTE
WB WET BULB
WCO WALL CLEAN OUT
WH WALL HYDRANT
Abbreviations
Type (See Schedule)
Max NC Rating
Design Airflow Rate
RTU-1
10.0 ton
RTU-1
180000 Btu/h
180 CFH
3.7 GPM
VAV 1-2
Design Water Flow
Operating Weight
Heating Capacity
Nominal Cooling Capacity
Mechanical Devices
GWR
GWS
Geothermal-Water Return
Geothermal-Water Supply
Existing Relocated Equipment(R)AHU-3
AC AIR CONDITIONING UNIT
ACCU AIR COOLING CONDENSING UNIT
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
B BOILER
CH CHILLER
CT COOLING TOWER
CUH CABINET UNIT HEATER
CHWP CHILLED WATER PUMP
DBP DOMESTIC WATER BOOSTER PUMP
DC DUCT MOUNTED COIL
DCP DOMESTIC WATER CIRCULATING PUMP
EF EXHAUST FAN
EDC ELECTRIC DUCT COIL
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
FCU FAN COIL UNIT
FP FIRE PUMP
GI GREASE INTERCEPTOR
GRV GRAVITY ROOF VENTILATOR
HWP HEATING WATER PUMP
HRU HEAT RECOVERY UNIT
PRV POWER ROOF VENTILATOR
RE RETURN/EXHAUST FAN
RTU ROOFTOP UNIT
SP SUMP PUMP
UH UNIT HEATER
WH WATER HEATER
Equipment Abbreviations
Damper Types
Laboratory Hood
Unit Identity
Valve Types
2" CHECK
2" BAL
3" CIRC
2" GATE
2" PRV
2" STRAIN
2" M-CNTRL
2" BV
1" GAS-CNTRL
Alternate Check Valve
1" REG
1" GAS COCK
1" PLUG
2" BFV
2" GLOBE
2" LOCK
4" 3-WAY CNTRL
2" QUICK
FLUE
C/A
S/A
V/A
O/A
R/A
L/A
T/A
E/A
KED
LH
ETS
Round Supply Duct Rise / Drop
Rect. Return Duct Rise / Drop
Round Return Duct Rise / Drop
Rect. Exhaust Duct Rise / Drop
Round Exhaust Duct Rise / Drop
(E)
EF-XX
500 CFM
AC-1
AFF:7'-0" Bottom of Equipment Height
Carbon Dioxide Detector
Carbon Monoxide Detector
Hydrogen Gas Detector
Hazardous Gas Detector
Nitrogen Dioxide Detector
Oxygen Gas Detector
Smoke Damper
Fire Damper
Comb. Fire/ Smoke Damper
Manual Damper
Motorized Damper
Backdraft Damper
Pipe Rise / Drop
Linear Diffuser
6"Ø
CD11 100
TYP. X 4
10"Ø/24x24 H6/9/1729
CD3 500
8"Ø/2s/4'-0"L
LD8 200
18"x10"
SG1 500
AFF:9'-0"
Neck Size Airflow
Airflow
Mounting Elevation (Centerline)
Nominal Duct Size
Airflow Neck Size/ Slot(s)/ Active Length
16"x16"
RG1 800
AFF:9'-0"
12"x12"/24x24
RG2 500
Airflow
Mounting Elevation (Centerline)
Nominal Duct Size
Airflow Neck Size / Module Size
Max NC Rating
Type Count for Space
Unit Identity
Gas Supply Input Rate
ET-1
379 lb
Humidity Sensor
Humidistat
Thermostat
Temp/ CO2 Sensor
Temp/ Humidity Sensor
Temperature Sensor
AHU-1
Ball Valve
Balancing Valve
Butterfly Valve
Check Valve
Circuit Setter
Gate Valve
Globe Valve
Locked Shield Valve
Pressure Reducing Valve
Quick Opening Valve
Fluid Strainer
Elec. Control Valve
3-Way Elec. Valve
Emergency Gas Shutoff
Plug Valve
Gas Shutoff Cock
Gas Regulator
2" CHECK
Throw Pattern
Room
Sidewall Supply Grille
Round Ceiling Diffuser
Square Ceiling Diffuser
Sidewall Return Grille
Ceiling Return
1. THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR FULLY
OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT.
2. CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE BUT ARE GIVEN AS AN AID TO THE
CONTRACTOR AND TO INDICATE THE QUALITY REQUIRED. CONTRACTOR IS RESPONSIBLE FOR A
COMPLETE DESCRIPTION OF MATERIAL ON THESE DRAWINGS AND IN THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES PRECEDENCE OVER THE CATALOG NUMBER.
THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN.
3. CONTRACTOR SHALL VERIFY THAT FIXTURES SUPPLIED ARE APPROVED PER ALL APPLICABLE STATE, LOCAL AND GOVERNING AUTHORITIES.
4. ALL FIXTURES SHALL CONFORM TO FEDERAL ACT S.3874.
5. INVERT ELEVATIONS ARE FROM EXISTING DRAWINGS AND MAY NOT BE ACCURATE. VERIFY ALL
ELEVATIONS BEFORE BEGINNING WORK.
6. VERIFY UNDERGROUND PIPE SIZES, INVERT ELEVATIONS, AND LOCATIONS PRIOR TO BEGINNING ANY
WORK.
7. REFER TO THE PLUMBING ROUGH-IN SCHEDULE FOR THE SIZES OF BRANCH PIPES TO PLUMBING
FIXTURES.
8. FOR CLARITY, NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES. ANGLE STOPS SHALL NOT BE CONSIDERED SHUTOFF
VALVES.
9. EXISTING CONDITIONS ON DEMOLITION PLANS ARE PROVIDED TO INDICATE THE GENERAL SCOPE OF ITEMS TO BE REMOVED. REFER TO SPECIFICATION SECTION 22 05 05 FOR ADDITIONAL DEMOLITION
INFORMATION.
10. P.C. SHALL CUT AND PATCH EXISTING AS REQUIRED FOR NEW OR DEMOLITION WORK UNLESS NOTED
OTHERWISE. REFER TO SPECIFICATION SECTION 22 05 05 FOR ADDITIONAL INFORMATION.
PLUMBING GENERAL NOTES
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE DIAGRAMMATIC AND
MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS. DRAWINGS SHOW THE GENERAL
ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC., AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY
AS ACTUAL BUILDING CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. CONTRACTORS SHALL REFER TO ARCHITECTURAL SPECIFICATIONS AND DRAWINGS FOR DIMENSIONS AS WELL AS SPECIFICATIONS AND DRAWINGS OF OTHER DISCIPLINES AND FOR GENERAL INFORMATION
NECESSARY TO COMPLETE THE WORK.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER
BEFORE PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE REASONABLE
ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER ACCESS.
5. ALL MATERIALS, EQUIPMENT AND METHOD OF INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS, THE REGULATIONS, CODES, ORDINANCES AND LAWS OF LOCAL, STATE AND OTHER AUTHORITIES HAVING LAWFUL JURISDICTION.
6. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO COORDINATE
SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR EXPENSE TO OTHERS.
7. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL CHANGES
REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF DESIGN.
8. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER THAN
SPRINKLERS.
9. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR
PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND FINISH.
10. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE PANEL TYPE AND COLOR
WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS PANELS PRIOR TO BIDDING.
11. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING, AND DUCTS PENETRATE. PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH
WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
12. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO
ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
13. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL RELEVANT SPEC SECTIONS. SEAL
SLEEVE PERIMETER TO BE WATERTIGHT.
14. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND REQUIRED
SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS, PIPING, DUCTWORK, ETC.
15. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
16. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR STARTERS, SWITCHES, AND DISCONNECTS. THE MECHANICAL AND PLUMBING CONTRACTORS SHALL MAINTAIN ALL WORKING CLEARANCES PER CODE FOR THE ELECTRICAL EQUIPMENT. NO PIPING (OR DUCTWORK)
SHALL BE ROUTED OVER, UNDER OR ADJACENT TO ELECTRICAL EQUIPMENT. COORDINATE WITH
ELECTRICAL CONTRACTOR PRIOR TO ROUGH-IN. ANY CONFLICTS WILL RESULT IN THE PIPING (AND
DUCTWORK) BEING RELOCATED AT THE CONTRACTOR'S EXPENSE.
17. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL EXTEND
MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.
18. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER NON- STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE CRACKED CONCRETE
APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
MECHANICAL GENERAL NOTES
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO,PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
A. A COPY OF "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS" BY SMACNA, ANSI/SMACNA 001-2008 SHALL BE PROVIDED BY THE CONTRACTOR AND KEPT ON THE JOB SITE AT ALL
TIMES.
B. ALL MECHANIC, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED OR BRACED TO
MEET THE FORCE AND DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2019 CBC, SECTION
161A.1.18 THROUGH 161A.1.26 AND ASCE 7-10 CHAPTERS 13, 29, AND 30.
C. PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-10 SECTION 13.3 AS DEFINED IN ASCE 7-10 SECTION 13.6.8, 13.6.7, AND 2019 CBC SECTION 1616A.1.23, 1616A.1.24, 1616A.1.25 AND 1616A.1.26.
SEISMIC MECHANICAL GENERAL NOTES
CA
CD
CW
F-CW
NPW
S-CW
HW
HW 140°
HW-R
HW-R 140°
GV
GW
G
OV
OW
PD
V
SS
SHWR
SHWS
SD
OSD
Plumbing SymbolsGeneral Plan Symbols
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN
THIS SET.THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
LP
Identity Type
RO
ID
2000 SF
6" SD-1
Ø ROUND
ABV ABOVE
AC AIR CONDITIONING
AD AREA DRAIN
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
AFUE ANNUAL FUEL UTILIZATION EFFICIENCY
ALT ALTERNATE
AP ACCESS PANEL
ARCH ARCHITECT/ARCHITECTURAL
BFF BELOW FINISHED FLOOR
BLW BELOW
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER HOUR
CAP CAPACITY
CB CATCH BASIN
CFM CUBIC FEET PER MINUTE
CLG CEILING
CO CLEAN OUT
CW COLD WATER
D DEGREE
DB DRY BULB
DIA DIAMETER
DN DOWN
DW DISTILLED WATER
EA EACH
EAT ENTERING AIR TEMPERATURE
ELEC ELECTRICAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
E/A EXHAUST AIR
EXIST EXISTING
F DEGREES FAHRENHEIT
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FL FLOOR
FO FUEL OIL
FOV FUEL OIL VENT
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FPM FEET PER MINUTE
FS FLOOR SINK
FT FOOT/FEET
FTR FIN TUBE RADIATION
GAL GALLON
GF GAS-FIRED
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
GW GREASE WASTE
HB HOSE BIB
HP HORSE POWER
HTG HEATING
HTR HEATER
HW HOT WATER
HYD HYDRANT
ID INDIRECT
IN INCH
INV INVERT
LB POUND
LB/HR POUNDS PER HOUR
LAT LEAVING AIR TEMPERATURE
LP LOW PRESSURE
LPG LIQUEFIED PETROLEUM GAS
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M/A MIXED AIR
MAX MAXIMUM
MBH ONE THOUSAND BTU PER HOUR
MCF ONE THOUSAND CUBIC FEET
MD MOTORIZED DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTR MOTOR
MU/A MAKE-UP/AIR
NC NOISE CRITERIA
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NUMBER
NO NORMALLY OPEN
NTS NOT TO SCALE
O OXYGEN
O/A OUTSIDE AIR
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP
PIV POST INDICATOR VALVE
PLBG PLUMBING
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PWR POWER
R DUCT RISER
R/A RETURN AIR
RCP RADIANT CEILING PANEL
RD ROOF DRAIN
REC RECESSED
RED REDUCER
RH RELATIVE HUMIDITY
RL/A RELIEF AIR
RM ROOM
RPM REVOLUTIONS PER MINUTE
RW RAIN WATER
SF SQUARE FOOT
S/A SUPPLY AIR
SAN SANITARY
SF SQUARE FOOT
SD SMOKE DAMPER
SM SURFACE MOUNT
SP STANDPIPE
SP STATIC PRESSURE
STM STEAM
T THERMOSTAT
TD TEMPERATURE DROP
TDR TRENCH DRAIN
TEMP TEMPERATURE
TYP TYPICAL
UG UNDERGROUND
VAC VACUUM
V VENT
VAV VARIABLE AIR VOLUME
VENT VENTILATION
VTR VENT THROUGH ROOF
W WASTE
WB WET BULB
WCO WALL CLEAN OUT
WH WALL HYDRANT
Abbreviations
AC AIR CONDITIONING UNIT
ACCU AIR COOLING CONDENSING UNIT
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
B BOILER
CH CHILLER
CT COOLING TOWER
CUH CABINET UNIT HEATER
CHWP CHILLED WATER PUMP
DBP DOMESTIC WATER BOOSTER PUMP
DC DUCT MOUNTED COIL
DCP DOMESTIC WATER CIRCULATING PUMP
EF EXHAUST FAN
EDC ELECTRIC DUCT COIL
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
FCU FAN COIL UNIT
FP FIRE PUMP
GI GREASE INTERCEPTOR
GRV GRAVITY ROOF VENTILATOR
HWP HEATING WATER PUMP
HRU HEAT RECOVERY UNIT
PRV POWER ROOF VENTILATOR
RE RETURN/EXHAUST FAN
RTU ROOFTOP UNIT
SP SUMP PUMP
UH UNIT HEATER
WH WATER HEATER
Equipment Abbreviations
2 DFU
0" FD-1
Floor Drain
3" AD-1
3" FS-4
6" DD-1
3" HD-1
Plumbing Fixture Notes
Floor Drain w/ Trap Primer "P" Indicates Primer Connection
Drainage Fixture Units
8" SD-12
Rainfall Surface Area
Pipe Accessory Notes
Floor Drain w/ Deep Seal Trap
Floor Drain w/ Integral Cleanout
2" FD-3P
4" FCO
Area Drain (No Trap)
2" CHECK
2" BALANCE
2" CIRC
1" T/V
2" GATE
2" PRV
2" STRAIN
2" QUICK
2" M-CNTRL
2" S/O
TMV-XT/P
TMVEM
PRIMER
2" METER
1 1/2" METER
1" GAS-CNTRL
2" BACKWATER
Alternate Check Valve
1" REG
1" GAS COCK
1" PLUG
Double Check Valve
Reduced Pressure Zone
Natural Gas
Condensate Drain
Liquid Propane
Combination DWV
Compressed Air
Domestic Cold-Water
Non-Potable Water
Soft Cold-Water
Filtered Cold-Water
Reverse Osmosis Water
Domestic Hot-Water
Domestic Hot-Water 140°
Hot-Water Recirculation
Hot-Water Recirculation 140°
Grease Vent
Grease Waste
Indirect Drain
Oil Vent
Oil Waste
Pump Discharge
Sanitary Vent
Sanitary Drain
Solar Water Return
Solar Water Supply
Storm Drain
Storm Overflow
WV Sanitary Wet Vent
(E)
2"
Existing Pipe To Remain
Pipe To Be Demolished
Above Ground Piping
Nomi…