5 of 5 899-MM-FY21-006_Bidding Document Plans_2023-04-11.pdf

PDF 3 MB Posted

Attached to
Y1PZ--899-MM-FY24 Drainage in Columbarium 1-5, & Remodel Existing Lookout area at NMCP, Proj# 899-MM-FY24-006
Solicitation number
36C78624B0014
Issued by

About this file

This document package includes bidding plans and specifications for site improvements and drainage work at the National Memorial Cemetery of the Pacific in Honolulu, Hawaii. The project involves constructing new sidewalks, landscaping, and irrigation systems at the cemetery's front entry pylon area. It will also remodel an existing lookout area and perform drainage work in Columbariums 1 through 5. The solicitation number for this opportunity is 36C78624B0014. The agency is the Department of Veterans Affairs National Cemetery Administration. Bids for the work must be submitted by April 30th, 2024 to Anderson Engineering of Minnesota. The plans provide details on construction limits, site features to be protected or repaired, planting and irrigation details, and specifications for turf, mulch and landscaping materials. The irrigation plan identifies the locations of new sprinkler heads, valves and piping to integrate with the existing cemetery irrigation system.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LP103

SIDEWALK AT FRONT ENTRY

PYLON LANDSCAPE PLAN

N

0 10' 20'

-------- Dwg. of

HONOLULU, HAWAII

NATIONAL MEMORIAL CEMETERY OF

THE PACIFIC SITE IMPROVEMENTS

04/11/2023

899-MM-FY22-006

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17054

VICINITY MAP

100% BIDDING

DOCUMENT SUBMITTAL

04/11/23

EXP. 04/30/24

CONSTRUCTION LIMITS

SILT FENCE

BIO-ROLL

EXISTING MAJOR CONTOUR

EXISTING MINOR CONTOUR

PROPOSED MAJOR CONTOUR

PROPOSED MINOR CONTOUR

NEW CURB AND GUTTER

INTERMENT SECTION LIMITS

REPAIR / REPLACE EXISTING ARTIFICAL TURF

SOD

MULCH

ROCK MULCH

LEGEND

NOTES:

1. ALL IRRIGATION SHALL BE MAINTAINED IN WORKING ORDER

FOR DURATION OF CONSTRUCTION. ANY IRRIGATION

DAMAGED OR REMOVED AS PART OF THE PROJECT SHALL

BE REPLACED INKIND.

2. RESTORATION LIMITS ARE APPROXIMATE. CONTRACTOR

SHALL RESTOR ALL DISTURBED AREAS IN KIND.

LP501

LANDSCAPE DETAILS

-------- Dwg. of

HONOLULU, HAWAII

NATIONAL MEMORIAL CEMETERY OF

THE PACIFIC SITE IMPROVEMENTS

04/11/2023

899-MM-FY22-006

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17054

100% BIDDING

DOCUMENT SUBMITTAL

04/11/23

EXP. 04/30/24

NORTHWEST

PREVAILING

WINDS

SOUTHEAST

PREVAILING

WINDS

TREE TIE SECURED TO

STAKE. SECURE TO TREE

WITH ANTI-CHAFFING

MATERIAL. ALLOW FOR

MOVEMENT OF TREE.

(2) TREE STAKES DRIVEN A MIN. 2'

BELOW GRADE (NW & SE)

HARDWOOD MULCH

LAWN

NOTE:

-3" DP. SHREDDED HARDWOOD MULCH SHALL BE USED IN

ALL LANDSCAPE PLANTINGS AREAS AND UNDER TREES

ISOLATED FROM PLANTING AREAS UNLESS IDENTIFIED

OTHERWISE.

-MULTI-STEM TREES SHALL NOT RECEIVE STAKING.

THEY SHALL CONFORM TO ALL OTHER DECIDUOUS

TREE PLANTING REQUIREMENTS.

3x

ROOT

BALL

2"

CENTER TREE IN HOLE, UPRIGHT

SINGLE STRAIGHT LEADER

TREE TIE SECURED TO STAKE. SECURE TO

TREE WITH ANTI-CHAFFING MATERIAL.

ALLOW FOR MOVEMENT OF TREE.

WRAP TREE WITH TREE WRAPPING

MATERIAL AS SPECIFIED TO 1ST BRANCH

LAWN OR PLANTING BED EDGE

(SPADE EDGE IN ALL LAWN AREAS)

6" MIN. DIA. EARTH SAUCER

(2) TREE STAKES DRIVEN A MIN. 2'

BELOW GRADE (NW & SW)

3" DEPTH HARDWOOD MULCH

3" HEIGHT TAMPED WATER BASIN AT

EDGE OF EARTH SAUCER

FINISHED GRADE

REMOVE BURLAP, TWINE, ROPE AND

WIRE FROM TOP HALF OF

ROOTBALL

PLANTING SOIL

MOUND MIN. 6"

UNDISTURBED OR COMPACTED SOIL

AFTER EXPOSING

TREE ROOT FLAIR,

PLANT SO ROOT

FLAIR IS AT 2"

ABOVE ADJACENT

FINISH GRADE

LAWN

P L A

N

T I N

G

B

E D

BOUNDARY BETWEEN LAWN AND

PLANTING AREA AS SHOWN ON PLAN

STEEL LANDSCAPE EDGING 1/4"

THICK BY 8" DP.

LANDSCAPE EDGING STAKE

16" LONG x 10ga INSTALLED

4 PER EVERY 10 LN. FT

3" DP. MULCH

LANDSCAPE FABRIC IF SPECIFIED

SPECIFIED PLANTING SOIL

SUBGRADE

6" DEEP

SHOVEL CUT

NOTE:

- KEEP MULCH APPX. 2" OFF PLANT TRUNK OR STEM

- SEE PLANT SCHEDULE FOR EACH PLANT'S APPROPRIATE O.C.

SPACING

O

C

S

P

A

C

I

N

G

C

S P

A C

I N

G

EDGE OF GROUNDCOVER

AREA/WALK EDGE

DISTANCE FROM EDGE

IS THE SPECIFIED

O.C. SPACING

TRIANGULAR SPACE,

AT SPECIFIED O.C.

DISTANCE - EQUIDISTANT

PLANT CENTER

HARDWOOD MULCH

ROOTBALL

PLANTING SOIL

NATIVE SOIL

LP501

PLANT SPACING / LAYOUT DETAIL

SCALE: NTS

LP501

LANDSCAPE EDGER DETAIL

SCALE: NTS

LP501

DECIDUOUS TREE PLANTING DETAIL

SCALE: NTS

LP501

DECIDUOUS TREE STAKING DETAIL

SCALE: NTS

1"

2"

2"

1"

TIE INTO EXISTING

IRRIGATION MAINLINE

AND RESTRAIN -

CONFIRM ACTUAL

LOCATION IN FIELD

2"

VERIFY STATION COUNTS FOR

INDIVIDUAL STATION CONTROL AND

CONNECT NEW VALVES TO EXISTING

IRRIGATION CONTROLLER(S)

SYMBOL MANUFACTURER/MODEL/DESCRIPTION

Hunter I-20-04 w/ MPR-35 Nozzles

Turf Rotor, 4in. Pop-Up. Adjustable and Full Circle. Plastic Riser.

Drain Check Valve. MPR-35 Nozzles.

SYMBOL MANUFACTURER/MODEL/DESCRIPTION

Griswold 100-DWS-PRV

1" Brass, In-Line, On-Off, Solenoid Control Valve, Normally

Closed, Self-Cleaning, Slow-Closing and Opening Feature.

Pressure Reducing.

Irrigation Lateral Line: PVC Schedule 40

(All 1" Unless Otherwise Noted On Plan)

Irrigation Mainline: PVC Schedule 40

LEGEND

IR101

SIDEWALK AT FRONT ENTRY

PYLON IRRIGATION PLAN

N

0 10' 20'

CCEC Dwg. of

HONOLULU, HAWAII

NATIONAL MEMORIAL CEMETERY OF

THE PACIFIC SITE IMPROVEMENTS

02/20/2023

899-MM-FY22-006

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17054

VICINITY MAP

100% CONSTRUCTION

DOCUMENT SUBMITTAL

100% BIDDING

DOCUMENT SUBMITTAL

27 28

ESNGESON

SCALE:

THRUST BLOCK DETAIL

NONE

SCALE:

ELECTRIC VALVE W/ PRV

AND VALVE BOX

NONE SCALE:

TURF ROTOR

NONE

IR501

IRRIGATION DETAILS

CCEC Dwg. of

HONOLULU, HAWAII

NATIONAL MEMORIAL CEMETERY OF

THE PACIFIC SITE IMPROVEMENTS

02/20/2023

899-MM-FY22-006

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17054

100% CONSTRUCTION

DOCUMENT SUBMITTAL

100% BIDDING

DOCUMENT SUBMITTAL

File details come from the government source that posted it. Updated .