S06_Amendment-0002 Attachment-1_Drawings_ 858CM3020.pdf
PDF 16 MB Posted
- Solicitation number
- 36C78621B0018
About this file
This document provides details regarding a federal contract solicitation for repair and maintenance work at the Little Rock National Cemetery in Little Rock, Arkansas. The solicitation number is 36C78621B0018 and will be issued on or about August 4, 2021 for project 858CM3020. The work includes repair and maintenance of administrative and maintenance buildings at the cemetery. The acquisition will be conducted as an Invitation for Bid and has an estimated value between $500,000 and $1,000,000. The NAICS code is 236220 for commercial and institutional building construction with a size standard of $36.5 million. This procurement is set aside 100% for Service-Disabled Veteran Owned Small Businesses. Bids are due on the date specified in the IFB. Interested parties must register on Beta.SAM.gov and Vendor Information Pages and have CVE verification to be considered. The contracting officer for this opportunity is Jerry L. Hodson Jr. and inquiries can be directed to the provided email address.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:3
PM
GI-000
COVER SHEET RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
Department of Veterans Affairs
2523 Springer Blvd. LITTLE ROCK, AR. 72206
PROJECT # 858CM3020
LOCATION MAP SITE MAP
SHEET INDEX:
BID DOCUMENTS
GENERAL
GI-000 COVER SHEET
GI-001 SITE PLAN
ARCHITECTURAL
AD-100 MAINTENANCE BLDG. FLOOR PLAN - DEMO
AD-201 MAINTENANCE BLDG. EXTERIOR ELEVATIONS - DEMO
AD-202 MAINTENANCE BLDG. EXTERIOR ELEVATIONS - DEMO
AS-100 MAINTENANCE BLDG. FLOOR PLAN
AS-102 MAINTENANCE BLDG. ROOF PLAN
AS-104 MAINTENANCE BLDG. REFLECTED CEILING PLAN
AS-200 MAINTENANCE BLDG. EXTERIOR ELEVATIONS
AS-201 MAINTENANCE BLDG. EXTERIOR ELEVATIONS
AS-600 DOOR / WINDOW / ROOM FINISH SCHEDULES AND DETAILS
ADD / ALTER OPTION
AD-101 ADMIN. BLDG. FLOOR PLAN - DEMO
AS-101 ADMIN. BLDG. FLOOR PLAN
AS-103 ADMIN. BLDG. ROOF PLAN
PLUMBING
P-001 PLUMBING GENERAL NOTES, SCHEDULES, & DETAILS
PD-101 MAINTENANCE BLDG. PLUMBING DEMO PLAN
P-101 MAINTENANCE BLDG. PLUMBING PLAN
MECHANICAL
M-001 MECHANICAL GENERAL NOTES, SCHEDULES, & DETAILS
MD-101 MAINTENANCE BLDG. MECHANICAL DEMO PLAN
M-101 MAINTENANCE BLDG. MECHANICAL PLAN
M-102 MAINTENANCE BLDG. MECHANICAL ROOF PLAN
ELECTRICAL
E-001 ELECTRICAL SYMBOLS
ELD-101 MAINTENANCE BLDG. LIGHTING DEMO PLAN
EPD-101 MAINTENANCE BLDG. POWER DEMO PLAN
EL-101 MAINTENANCE BLDG. LIGHTING PLAN
EP-101 MAINTENANCE BLDG. POWER PLAN
EY-101 MAINTENANCE BLDG. FIRE ALARM PLAN
EY-102 MAINTENANCE BLDG. LIGHTNING PROTECTION PLAN
E-501 ELECTRICAL DETAILS
E-601 ELECTRICAL SCHEDULES AND DIAGRAMS - MAINTENANCE BUILDING
ADD / ALTER OPTION
ED-201 ADMIN. BLDG. DEMO PLAN
EL-201 ADMIN. BLDG. LIGHTING PLAN
EP-201 ADMIN. BLDG. POWER PLAN
EY-201 ADMIN. BLDG. LIGHTNING PROTECTION PLAN
E-602 ELECTRICAL SCHEDULES AND DIAGRAMS - ADMIN. BUILDING
Revisions: Date:
S
ADMIN
BUILDING
MAINTENANCE
BUILDING
PROPOSED CONTRACTOR'S
STAGING AREA
REMOVE EXISTING CLAY TILE
SEWER PIPE FROM EXISTING
MANHOLE TO 5'-0" OUTSIDE OF
MAINTENANCE BUILDING AS
SHOWN. REPLACE EXISTING
SEWER PIPE WITH 6" PVC
PIPE. VERIFY EXACT LOCATION
IN FIELD.
V.
I.F
5'
0"
V.I.F.
53' - 1 1/2"
V.
I.F
8'
4"
LOCATION OF EXISTING
MANHOLE, VERIFY IN FIELD.
EXISTING VEHICLE WASH RACK
ASSEMBLY TO BE REMOVED
AND REPLACED.
ADD ALTERNATE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:3
PM
GI-001
SITE PLAN RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/8" = 1'-0"1 EXISTING SITE PLAN
WH
AD-2022
AD-201
AD-201 2
AD-202
BREAK RM
OFFICE
CHEMICAL
STORAGE
BAY 2 WORK BAY 1 WORK
BAY 3 WORK
EMPLOYEE
RESTROOM
STORAGE ROOM
3 7
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND DISCARDED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AD-100
MAINTENANCE BLDG. FLOOR
PLAN - DEMO
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. FLOOR PLAN - DEMO
1 EXISTING DOOR AND FRAME - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
2 EXISTING PARTITION TO REMAIN - EXISTING FINISHES AT FACE
OF PARTITION COMMON TO THE IDENTIFIED WORK AREA ARE TO
BE PATCHED, REPAIRED AND PREPARED FOR NEW APPLIED
FINISHES AS SCHEDULED.
3 EXISTING FLOORING - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY TO LIMITS SHOWN.
4 EXISTING CASEWORK ASSEMBLY TO BE REMOVED.
5 EXISTING PLUMBING FIXTURE - REMOVE AND DISPOSE OF
ENTIRE ASSEMBLY. REF. MEP DRAWINGS.
6 EXISTING WINDOW - REMOVE AND DISPOSE ENTIRE ASSEMBLY.
7 EXISTING LIGHT FIXTURES TO BE REMOVED. PREPARE EXISTING
CEILINGS FOR NEW FIXTURES. REF. ELECTRICAL DRAWINGS.
GRAPHIC LEGEND
KEY NOTES
BID DOCUMENTS
Revisions: Date:
8 EXISTING MEZZANINE STORAGE AREA TO REMAIN. PREPARE
EXISTING AREA TO RECEIVE NEW DROP RETRACTABLE
ACCESS STAIRS.
9 EXISTING VEHICLE WASH RACK ASSEMBLY TO BE REMOVED
AND REPLACED.
2 2 2 2
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND DISCARDED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AD-201
MAINTENANCE BLDG. EXTERIOR
ELEVATIONS - DEMO
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - NORTH - DEMO
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - EAST - DEMO
1 EXISTING WINDOW - REMOVE AND DISPOSE ENTIRE ASSEMBLY.
2 EXISTING DOOR AND FRAME - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
3 REMOVE EXISTING ROLL-UP DOOR, EXISTING TRACKS TO BE
REMAIN.
4 EXISTING LIGHT FIXTURE TO BE REMOVED, REF. ELECTRICAL
DRAWINGS.
GRAPHIC LEGEND
KEY NOTES
BID DOCUMENTS
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND DISCARDED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AD-202
MAINTENANCE BLDG. EXTERIOR
ELEVATIONS - DEMO
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - SOUTH - DEMO
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - WEST - DEMO
1 REMOVE EXISTING ROLL-UP DOOR, EXISTING TRACKS TO BE
REMAIN.
GRAPHIC LEGEND
KEY NOTES
WH
BREAKROOM
CHEMICAL
STORAGEOFFICE
BAY 1 WORK
BAY 2 WORK
BAY 3 WORK
EMPLOYEE
RESTROOM
STORAGE ROOM
A
8 9
AS-100
AS-200 2
AS-200
AS-201
AS-2012
1 21
5 5
7 81
5' - 1" 3' - 0"
2'
1'
8" 2'
6"
2'
2' - 6"2' - 6"3' - 0"
5'
6" 1'
6"
2' - 6" 2' - 6"
AS-100
2'
6"
1/4" PLYWOOD BACKING
3/4" PLYWOOD CABINET DOOR
WITH PLASTIC
LAMINATE FINISH (PL-1) AT
ALL SURFACES
DOUBLE SLOTTED
METAL STANDARDS -
FLUSH MOUNTED
(TYPICAL)
PROVIDE FIRE
RETARDENT TREATED
2X6 WOOD BLOCKING
AS REQUIRED
PROVIDE FIRE
RETARDENT TREATED
2X6 WOOD BLOCKING
AS REQUIRED
3/4" ADJUSTABLE
PLYWOOD SHELVING
WITH PLASTIC LAMINATE (PL-1)
FINISH AT ALL SURFACES
FIRE RETARDENT TREATED
2X8 CONTINUOUS FRAMING
AT CABINETS CUT
BETWEEN STUDS
2' - 0"
0' - 8"
0'
1/
2" 0'
2"
0' - 6"
0'
9"
2'
R
EF
ER
T
O
IN
TE
R
IO
R
E
LE
VA
TI
O N
S
PLASTIC LAMINATE (PL-2)
COUNTERTOP, BACKSPLASH,
AND EDGES AS SCHEDULED
ON (2) LAYERS OF PLYWOOD
PLYWOOD BRACE LOCATED
BETWEEN LAVATORIES
PLASTIC LAMINATE (PL-1) APRON
COVER, SCREW ATTACHED
TO END SUPPORTS WITH
OVAL HEAD SCREWS AND
ESCUTCHEONS
BASE AS SCHEDULED
1' - 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AS-100
MAINTENANCE BLDG. FLOOR
PLAN
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC RJP
858CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. FLOOR PLAN - NEW
1 NEW PLUMBING FIXTURE, REF. MEP DRAWINGS.
2 NEW CASEWORK.
3 NEW FLOORING, PAINT AND FINISHES, REF. SCHEDULE OF
FINISHES SPECIFICATION.
4 PATCH AND REPAIR EXISTING WALLS TO RECEIVE NEW PAINT
FINISH.
5 NEW DOOR AND FRAME ASSEMBLY.
6 NEW ROLL-UP DOOR ASSEMBLY.
7 PROVIDE LOCKABLE HARDWARE FOR WINDOW ASSEMBLY.
8 NEW WINDOW ASSEMBLY.
9 EXISTING OPENING TO BE INFILLED WITH WALL ASSEMBLY TO
MATCH EXISTING CONSTRUCTION.
KEY NOTES
SCALE: 1/2" = 1'-0"2 BREAKROOM INTERIOR ELEVATION
BID DOCUMENTS
SCALE: 1" = 1'-0"3 MILLWORK DETAIL
10 NEW VEHICLE WASH RACK ASSEMBLY.
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AS-102
MAINTENANCE BLDG. ROOF
PLAN
RENOVATE MAINTENANCE
FACILITY
07/20/2021 Checker Author
858CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. ROOF PLAN
KEY NOTES
1 NEW LIGHTNING PROTECTION SYSTEM, REF. ELECTRICAL
DRAWINGS.
BREAKROOM
CHEMICAL
STORAGE
OFFICE
BAY 1 WORK
BAY 2 WORK
BAY 3 WORK
EMPLOYEE
RESTROOMSTORAGE ROOM
AS-200 2
AS-200
AS-201
AS-2012
1 1
OS
OS
2' X 4' LUMINAIRE OCCUPANCY SENSOROS
SINGLE SIDED EXIT SIGNAGE CEILING MOUNTED
6" X 4' LUMINAIRE EMERGENCY LIGHT
FIXTURE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AS-104
MAINTENANCE BLDG.
REFLECTED CEILING PLAN
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BUILDING REFLECTED CEILING PLAN
1 NEW LIGHT FIXTURE, REF. ELECTRICAL DRAWINGS.
2 PATCH AND REPAIR EXISTING CEILING TO RECEIVE NEW PAINT
FINISH.
3 NEW CEILING ACCESS PANEL.
4 NEW DROP RETRACTABLE MEZZANINE ACCESS STAIRS
ASSEMBLY.
KEY NOTES
GRAPHIC LEGEND
A
8 9
2 1
2 2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:3
PM
AS-200
MAINTENANCE BLDG. EXTERIOR
ELEVATIONS
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - EAST
1 NEW LIGHT FIXTURE, REF. ELECTRICAL DRAWINGS.
2 NEW DOOR AND FRAME ASSEMBLY.
3 NEW ROLL-UP DOOR ASSEMBLY.
4 NEW WINDOW ASSEMBLY.
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - NORTH
KEY NOTES
6 7
1 1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:3
PM
AS-201
MAINTENANCE BLDG. EXTERIOR
ELEVATIONS
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
1 NEW ROLL-UP DOOR ASSEMBLY.
2 NEW LIGHT FIXTURE, REF. ELECTRICAL DRAWINGS.
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - SOUTH
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - WEST
KEY NOTES
MIN. 3000 PSI CONCRETE REQ'D
GA0232 - 4 1/4"GA0232 - 4 1/4"
COILEXTERIOR
CP0001
FRONT
SLAT
BACK SLAT
POLYURETHANE
INSULATION
ASTRAGAL
BOTTOM BAR / SLAT DETAIL
WEATHERING
4" x 3 1/2" x 1/4"4" x 3 1/2" x 1/4"
4 1/4"
1/2" 1/2"
2 1/2"
6 1/4"
7 1/4"
4 1/4"
2 1/2"
6 1/4"
7 1/4"
7/8"3"
4"
16'-1"
16'-0"
36" 36"36" 36"
MK: 001
HEX HEAD CAP SCREW, GR. 8
- HEX HEAD NUT, GR. 8
- HARDENED FLAT WASHERS
HEX HEAD CAP SCREW, GR. 8
- HEX HEAD NUT, GR. 8
- HARDENED FLAT WASHERS
x 3-1/2"
MIN. EMBEDMENT DEPTH - 2-5/8"
SIMPSON WEDGE-ALL, - Ø3/8"
MIN. EMBEDMENT DEPTH - 2-5/8"
x 3-1/2"
MIN. 3000 PSI CONCRETE REQ'D
- Ø3/8" SIMPSON WEDGE-ALL,
1089 LBS STATIC LOAD
DESIGNED TO SUPPORT
STRUCTURE MUST BE
- Ø3/8-16 x 1-1/2" - Ø3/8-16 x 1-1/2"
AT ON CENTERAT ON CENTERAT ON CENTER AT ON CENTER
OPENING WIDTH
DISTANCE BETWEEN GUIDES
3/16" STEEL BRACKET PLATE ABOVE
PLAN OF OPENING
3" x 2" x 3/16" (TYP.)
3 1/2" x 3" x 1/4" (TYP.)
ASSEMBLY FASTENERS:WALL FASTENERS:WALL FASTENERS: ASSEMBLY FASTENERS:
2 3/4" 1 3/8"
1 1/2"
1 1/8"
2 3/4" 1 3/8"
1 1/8"
1 1/2"
AUXILIARY
HAND CHAIN
12-1/8"±
1-1/2" TOP HOOD BEAD
2"
O
PE
N
IN
G H
EI
G
H T
'L-TYPE' LINTEL
BRUSH SEAL
5"
?19-1/2"
O
VE
R
AL
L D
O O
R H
EI
G
H T
D O
O R
O
PE
N
IN
G H
EI
G
H T
WIDTH
H
EI
G H
T
TYPE "A"
FLUSH
TYPE "B"
FLUSH
NARROW LITE
WIDTH
H
EI
G H
T
4" 9"
2'
1" 3'
6"
TYPE "E"
ROLL-UP DOOR
WIDTH
H
EI
G H
T
TYPE "C"
FLUSH
WINDOW
WIDTH
H
EI
G H
T
8" 1' - 8" 8"
2'
6" 3'
6"
TYPE "D"
FLUSH
LOUVER
WIDTH
H
EI
G H
T
2'
0" 8"
0' - 8" 1' - 8" 0' - 8"
TYPE "A"
HOLLOW METAL FRAME
SINGLE DOOR
2" DOOR WIDTH 2"
2" D
O O
R H
EI
G
H T
TYPE "B"
STEEL ROLL-UP
DOOR FRAME
2" DOOR WIDTH 2"
2" D
O O
R H
EI
G
H T
TYPE WIDTH
WINDOW SCHEDULE
HEIGHT GLAZING FRAME COMMENTS
A 3' - 6" 4' - 6" ALUMINUM SINGLE HUNG
U-VALUE SHGC
CLEAR, LAMINATED, DOUBLE INSULATED, LOW-E 0.30 0.40 FIELD VERIFY EXISTING WINDOW SIZE, PROVIDE LOCKING HARDWARE.
3 3/4" 2"2"
2" 3/
8"
2" 3/
8"
7 5/8"
EXISTING WALL
ASSEMBLY
SEALANT
(BOTH SIDES)
HOLLOW METAL
DOOR FRAME
DOOR AS
SCHEDULED 3 3/4" 2"2"
2" 2"
7 5/8"
EXISTING WALL ASSEMBLY
SEALANT
(BOTH SIDES)
HOLLOW METAL
DOOR FRAME
DOOR AS
SCHEDULED
EXISTING WALL ASSEMBLY
EXISTING LINTEL
1/4" SHIM SPACE
WINDOW AS SCHEDULED
AIR SPACE
EXISTING FLASHING
EXISTING
FACE BRICK
SEALANT
METAL FLASHING
WITH DRIP
CONTINUOUS
BEAD OF SEALANT
(BOTH SIDES
OF WALL)
EXISTING WALL ASSEMBLY
1/4" SHIM SPACE
WINDOW AS SCHEDULED
AIR SPACE
EXISTING FLASHING,
OVERLAP NEW
FLASHING WITH
EXISTING FLASHING
EXISTING
FACE BRICK
CONTINUOUS
BEAD OF SEALANT
(BOTH SIDES
OF WALL)
EXISTING WALL ASSEMBLY
1/4" SHIM SPACE WINDOW AS SCHEDULED
AIR SPACE
EXISTING FLASHING,
OVERLAP NEW
FLASHING WITH
EXISTING FLASHING
EXISTING
FACE BRICK
CONTINUOUS
BEAD OF SEALANT
(BOTH SIDES
OF WALL)
2'
1"
3' - 6"
4'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:3
PM
AS-600
DOOR / WINDOW SCHEDULES
AND DETAILS
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME HARDWARE
GROUP NOTESWIDTH HEIGHT MATERIAL FINISH TYPE MATERIAL FINISH TYPE
1 3' - 0" 6' - 8" HOLLOW METAL PT-1 A HOLLOW METAL PT-1 A HW-19 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.40 2 3' - 0" 6' - 8" HOLLOW METAL PT-1 B HOLLOW METAL PT-1 A HW-14 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.40 3 3' - 0" 6' - 8" HOLLOW METAL PT-1 C HOLLOW METAL PT-1 A HW-11 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.40 4 3' - 0" 6' - 8" HOLLOW METAL PT-1 A HOLLOW METAL PT-1 A HW-15 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.40 5 3' - 0" 6' - 8" HOLLOW METAL PT-1 A HOLLOW METAL PT-1 A HW-19 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.40 6 10' - 0" 7' - 8" ALUMINUM N/A E EXISTING EXISTING EXISTING HW-6 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.125 7 10' - 0" 7' - 8" ALUMINUM N/A E EXISTING EXISTING EXISTING HW-6 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.125 8 10' - 0" 10' - 2" ALUMINUM N/A E EXISTING EXISTING EXISTING HW-6 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.125 9 10' - 0" 10' - 2" ALUMINUM N/A E EXISTING EXISTING EXISTING HW-6 FIELD VERIFY EXISTING SIZE, DOOR TO HAVE U VALUE OF 0.125
10 2' - 6" 6' - 8" SOLID CORE WOOD PL-1 D HOLLOW METAL PT-1 A HW-7
Grand total: 10
SCALE: 1/2" = 1'-0"
DOOR TYPES
SCALE: 1/2" = 1'-0"
DOOR FRAME TYPES
SCALE: 3" = 1'-0"3 HM DOOR FRAME HEAD
SCALE: 3" = 1'-0"4 HM DOOR FRAME JAMB
ROOM FINISH SCHEDULE
BUILDING ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING WINDOW TREATMENT REMARKS
MAINTENANCE BAY 1 WORK EXISTING EXISTING PT-1 PT-1 PT-1 PT-1 EXISTING
MAINTENANCE BREAKROOM VCT-1 RB-1 PT-1 PT-1 PT-1 PT-1 GYP BD. / PT-1
MAINTENANCE EMPLOYEE RESTROOM CT-2 CT-1 PT-1 / CT-1 PT-1 / CT-1 PT-1 / CT-1 PT-1 / CT-1 GYP BD. / PT-1
MAINTENANCE OFFICE VCT-1 RB-1 PT-1 PT-1 PT-1 PT-1 GYP BD. / PT-1
ADMIN MAP ROOM VCT-1 RB-1 PT-1 PT-1 PT-1 PT-1 GYP BD. / PT-1
ADMIN MEETING SPACE VCT-1 RB-1 PT-1 PT-1 PT-1 PT-1 GYP BD. / PT-1
ADMIN STAFF TOILET CT-2 CT-1 PT-1 / CT-1 PT-1 / CT-1 PT-1 / CT-1 PT-1 / CT-1 EXISTING
MATERIAL FINISH SCHEDULE
FINISH CODE MATERIAL TYPE BASIS OF DESIGN MANUFACTURE NO. PATTERN COLOR SIZE GROUT COMMENTS
CT-1 CERAMIC TILE INTERCERAMIC --- SUBWAY WALL TILE COLLECTION BONE WHITE 3" X 6" LIGHT GRAY PROVIDE TILE AND GROUT FULL COLOR SAMPLES FOR REVIEW.
CT-2 CERAMIC TILE INTERCERAMIC --- CATALINA PEBBLE 13" X 13" LIGHT GRAY PROVIDE TILE AND GROUT FULL COLOR SAMPLES FOR REVIEW.
PT-1 PAINT COORDINATE W/ NCA --- --- WHITE TO
MATCH
EXISTING
--- COORDINATE WITH NCA FOR EXISTING PAINT MANUFACTURER'S INFORMATION.
RB-1 RUBBER WALL BASE ARMSTRONG --- --- FLAGSTONE 4" ---
PL-1 PLASTIC LAMINATE WILSONART --- BRAZILWOOD --- --- --- COORDINATE WITH NCA TO MATCH ANY EXISTING PLASTIC LAMINATE, SUBMIT FULL RANGE
COLOR PALLETE
PL-2 PLASTIC LAMINATE WILSONART --- PEARL SOAPSTONE --- --- --- COORDINATE WITH NCA TO MATCH ANY EXISTING PLASTIC LAMINATE, SUBMIT FULL RANGE
COLOR PALLETE
VCT-1 VINYL COMPOSITION
TILE
ARMSTRONG 51803 PEARL WHITE --- 12"X12" ---
SCALE: 1 1/2" = 1'-0"5 WINDOW HEAD DETAIL
SCALE: 1 1/2" = 1'-0"6 WINDOW JAMB DETAIL
SCALE: 1 1/2" = 1'-0"7 WINDOW SILL DETAIL
SCALE: 3" = 1'-0"8 ROLL UP DOOR DETAILS
SCALE: 3/4" = 1'-0"9 ROLL UP DOOR SECTION
SCALE: 1/2" = 1'-0"
WINDOW TYPES10
1 2
DIRECTOR
GENERAL
OFFICE/LOBBY
BREEZEWAY
MEN'S
RESTROOM WOMEN'S
RESTROOM
STAFF TOILET
MECH.
OPERATIONAL
CENTER
MAP ROOM
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND DISCARDED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AD-101
ADMIN. BLDG. FLOOR PLAN -
DEMO
RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"1 ADMIN. BLDG. FLOOR PLAN - DEMO
1 EXISTING DOOR AND FRAME - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
2 EXISTING FLOORING - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY TO LIMITS SHOWN.
3 EXISTING PARTITION TO REMAIN - EXISTING FINISHES AT FACE
OF PARTITION COMMON TO THE IDENTIFIED WORK AREA ARE TO
BE PATCHED, REPAIRED AND PREPARED FOR NEW APPLIED
FINISHES AS SCHEDULED.
4 EXISTING INTERIOR PARTITION - REMOVE AND DISPOSE OF
ENTIRE ASSEMBLY AS REQUIRED TO ACCOMODATE NEW WORK,
INCLUDING ALL FINISHES.
GRAPHIC LEGEND
KEY NOTES
ADD ALTERNATE
BID DOCUMENTS
Revisions: Date:
5 DEMO PORTION OF EXISTING CEILING IN MAP ROOM AREA.
PREPARE EXISTING SUBSTRATE TO RECEIVE NEW CEILING
FINISH AS SCHEDULED.
STAFF TOILET
MECH.
MAP ROOM
DIRECTOR
BREEZEWAY
WOMEN'S
RESTROOM
MEN'S
RESTROOM
MEETING SPACE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AS-101
ADMIN. BLDG. FLOOR PLAN RENOVATE MAINTENANCE
FACILITY
07/20/2021 RHC MAG
858CM3020
SCALE: 1/4" = 1'-0"1 ADMIN. BLDG. FLOOR PLAN - NEW
1 NEW FLOORING, PAINT AND FINISHES, REF. SCHEDULE OF
FINISHES SPECIFICATION.
KEY NOTES
ADD ALTERNATE
BID DOCUMENTS
Revisions: Date:
ROOM FINISH
SCHEDULE ON SHEET AS-600.
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
LITTLE ROCK, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
LI
TT
LE
R O
C K
N
AT
IO
N
AL
C
EM
ET
ER
Y/
LI
TT
LE
R
O C
K N
AT
IO
N
AL
C
EM
ET
ER
Y.
rv t 7/
/2
3:
:2
PM
AS-103
ADMIN. BLDG. ROOF PLAN RENOVATE MAINTENANCE
FACILITY
07/20/2021 Checker Author
858CM3020
SCALE: 1/4" = 1'-0"1 ADMIN. BLDG. ROOF PLAN
KEY NOTES
1 NEW LIGHTNING PROTECTION SYSTEM, REF. ELECTRICAL
DRAWINGS.
ADD ALTERNATE
Michael EP Typewritten Text
ADD ALTERNATE
| Little Rock NC Maint.Bldg_858CM3020_Bid Documents_ArchDrawings_07202021.pdf |
| Sheets |
| AD-100 - MAINTENANCE BLDG. FLOOR PLAN - DEMO |
| AD-101 - ADMIN. BLDG. FLOOR PLAN - DEMO |
| AD-201 - MAINTENANCE BLDG. EXTERIOR ELEVATIONS - DEMO |
| AD-202 - MAINTENANCE BLDG. EXTERIOR ELEVATIONS - DEMO |
| AS-100 - MAINTENANCE BLDG. FLOOR PLAN |
| AS-101 - ADMIN. BLDG. FLOOR PLAN |
| AS-102 - MAINTENANCE BLDG. ROOF PLAN |
| AS-103 - ADMIN. BLDG. ROOF PLAN |
| AS-104 - MAINTENANCE BLDG. REFLECTED CEILING PLAN |
| AS-200 - MAINTENANCE BLDG. EXTERIOR ELEVATIONS |
| AS-201 - MAINTENANCE BLDG. EXTERIOR ELEVATIONS |
| AS-600 - DOOR / WINDOW SCHEDULES AND DETAILS |
| GI-000 - COVER SHEET |
| GI-001 - SITE PLAN |
File details come from the government source that posted it. Updated .