This is a UL Solutions Product iQ technical certification document for a nonbearing wall fire-resistance assembly (Design No. V497), certified November 15, 2022, for compliance with ANSI/UL 263 standards in the United States and CAN/ULC-S101 standards in Canada.

The assembly achieves 1-hour or 2-hour fire-resistance ratings and specifies five primary components: (1) floor and ceiling runners fabricated from minimum 25 MSG corrosion-protected steel with 1-1/4 inch minimum legs, fastened 24 inches on-center maximum; (2) steel studs of identical material composition spaced maximum 24 inches on-center and cut 3/8 to 3/4 inch less than assembly height, with an alternate option available from Marino/Ware (Viper25™); (3) laminating compound powder-type for bonding wallboard layers; (4) gypsum board from National Gypsum Co available in multiple configurations—two layers of 5/8-inch panels for 1-hour rating, three layers for alternate 1-hour rating, or four layers for 2-hour rating—with specific screw spacing and installation requirements; and (5) joint tape and compound for finishing. All products marked with UL or cUL certification marks are required. The document emphasizes that Authorities Having Jurisdiction must be consulted for specific installation and use requirements, and that technical service staff from product manufacturers should be contacted for field issue resolution.

View the file

Other files

File Type Posted
S06 - Amendment 0005 Complete Bid Abstract - Chillicothe 05052026.pdf PDF
S06 - Amendment 0005 36C77626B0018.pdf PDF
S06 - Amendment 0004 36C77626B0018.pdf PDF
S06 - Amendment 0004 - 52.222-90 -APR 2026.pdf PDF
S06 - Amendment 0004 - Addendum 1 - CD Drawings - Chillicothe EHRM.pdf PDF
S06 - Amendment 0003 - XUV.U465 _ Product iQ - Product iQ.pdf PDF
S06 - Amendment 0003 - Technical Responses - Chillicothe.pdf PDF
S06 - Amendment 0003 36C77626B0018.pdf PDF
36C77626B0018 0002.pdf PDF
Site_Visit_Sign_In_Sheet.pdf PDF
Amendment 0001 - Attachment 1 - DBA Wage Determination - Ross County_01022026.pdf PDF
Amendment 0001 - 36C77626B0018.pdf PDF
36C77626B0018_Chillicothe.pdf PDF
Attachment 1 - DBA Wage Determination - Licking County_01022026.pdf PDF
Attachment 6 - Chillicothe EHRM IU Tier 2 - Part-1.pdf PDF
Attachment 8 - Exhibits Chillicothe VAMC SOP.pdf PDF
Attachment 9 - PCRA ICRA Combined_ Chillicothe.pdf PDF
Attachment 7 - Chillicothe EHRM IU Tier 2 - Part-2.pdf PDF
Attachment 4 - Chillicothe EHRM Tier 2 100_Specs_Final_Part-1.pdf PDF
Attachment 2 - Site Visit Information - Chillicothe.docx DOCX document
Attachment 5 - Chillicothe EHRM Tier 2 100_Specs_Final_Part-2.pdf PDF
Attachment 3 - Limitations on Subcontracting - Chillicothe.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.

Authorities Having Jurisdiction should be consulted before construction.

Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.

When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction.

Only products which bear UL's Mark are considered Certified.

BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada

See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances

See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances

Design No. V497

November 15, 2022

Nonbearing Wall Rating - 1 or 2 Hr

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Product iQ® https://iq.ulprospector.com/en/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=BXUV.GuideInfo&ccnshorttitle=Fire-resistance+Ratings+-+ANSI/UL+263&objid=1074327030&cfgid=1073741824&version=versionless&parent_id=1073984818&sequence=1 https://iq.ulprospector.com/en/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=BXUV.GuideInfo&ccnshorttitle=Fire-resistance+Ratings+-+ANSI/UL+263&objid=1074327030&cfgid=1073741824&version=versionless&parent_id=1073984818&sequence=1 https://iq.ulprospector.com/en/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=BXUV7.GuideInfo&ccnshorttitle=Fire+Resistance+Ratings+-+CAN/ULC-S101+Certified+for+Canada&objid=1074205658&cfgid=1073741824&version=versionless&parent_id=1073984820&sequence=1 https://iq.ulprospector.com/en/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=BXUV7.GuideInfo&ccnshorttitle=Fire+Resistance+Ratings+-+CAN/ULC-S101+Certified+for+Canada&objid=1074205658&cfgid=1073741824&version=versionless&parent_id=1073984820&sequence=1 https://iq.ulprospector.com/en

1. Floor and Ceiling Runners — (Not Shown) — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min width to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24 in. OC max.

1A. Framing Members*— Floor and Ceiling Runners — (Not Shown) — As an alternate to Item 1. For use with Item 2A, channel shaped, min width to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24 in. OC max.

MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25™ Track

2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min 3-5/8 in. wide, min 1-1/4 in. flanges, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height.

2A. Steel Studs* — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min 3-5/8 in.

wide, min 1-1/4 in. flanges, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height.

MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25™

3. Laminating Compound — For use with Item 4 - Used to bond outer layer wallboard to inner layer wallboard. Powder type mixed with water in accordance with instructions shown on bags. Applied to entire surface of base layer wallboard. Applied with notched trowel producing continuous beads about 1/4 in. wide and 1/4 in. high.

4. Gypsum Board* — 1 Hr Rating - Applied to one side of steel studs (Item 2). Two layers of 5/8 in. gypsum panels with beveled, square or tapered edges. Gypsum panels applied vertically with joints centered over studs. Base layer applied with 1 in. Type S screws spaced 24 in. oc. Face layer applied vertically with joints centered over studs and offset from base layer joints by one stud cavity. Face layer applied with 1-5/8 in.

Type S screws spaced 12 in. oc starting with a 6 in. offset from the bottom of the gypsum panel.

NATIONAL GYPSUM CO — 5/8 in. thick Types eXP-C, FSL, FSW, FSK, FSW-3, FSW-5, FSW-G, FSK-G, FSW-6, FSW-8, FSW-C, FSMR-C, FSK-C, Type SBWB

4A. Gypsum Board* — (As an alternate to Items 3 and 4) -- 1 Hr Rating - Applied to one side of steel studs (Item 2). Three layers of 5/8 in. gypsum panels with beveled, square or tapered edges. Gypsum panels applied vertically or horizontally with vertical joints centered over studs and staggered one stud cavity in adjacent layers. Horizontal edge joints and horizontal butt joints in adjacent layers staggered a minimum of 12 in. Horizontal joints need not be backed by steel framing. First layer applied with 1 in. Type S screws spaced 24 in. oc. Second layer applied with 1-5/8 in. Type S screws spaced 24 in. oc. Face layer applied vertically 2- 1/4 in. Type S screws spaced 12 in. oc starting with a 6 in. offset from the bottom of the gypsum panel.

NATIONAL GYPSUM CO — 5/8 in. thick Type eXP-C, FSL, FSW, FSK, FSW-3, FSW-5, FSW-G, FSK-G, FSW-6, FSW-C, FSMR-C, FSK-C, Type SBWB

4B. Gypsum Board* — 1 Hr Rating - (As an alternate to Item 4A) - Nom. 5/16 in. thick gypsum panels applied vertically. Two layers of 5/16 in. for every single layer of 5/8 in. gypsum board described in Item 4A. Horizontal joints on the same side need not be staggered. Inner layer of each double 5/16 in. layer attached with

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service. Always look for the Mark on the product.

UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2.

The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2026 UL LLC."

fasteners, as described in item 4A, spaced 24 in. OC. Outer layer of each double 5/16 in. layer attached per Item 4A.

NATIONAL GYPSUM CO — Type FSW

4C. Gypsum Board* — 2 Hour Rating — Applied to one side of steel studs (Item 2). Four layers of 5/8 in.

gypsum panels with beveled, square or tapered edges. Gypsum panels applied vertically or horizontally with vertical joints centered over studs and staggered one stud cavity in adjacent layers. Horizontal edge joints and horizontal butt joints in adjacent layers staggered a minimum of 12 in. Horizontal joints need not be backed by steel framing. First layer applied with 1 in. Type S screws spaced 24 in. oc. Second layer applied with 1-5/8 in. Type S screws spaced 24 in. oc. Third layer applied with 2-1/2 in. Type S screws spaced 16 in. oc.

Fourth layer applied with 3" Type S screws spaced 12 in. o.c.

NATIONAL GYPSUM CO — 5/8 in. thick Type eXP-C, FSL, FSW, FSK, FSW-3, FSW-5, FSW-G, FSK-G, FSW-6, FSW-C, FSMR-C, FSK-C, Type SBWB

5. Joint Tape and Compound — (Not Shown) - Joints covered with joint compound and paper tape. Paper tape, nom 2 in. wide, embedded in first layer of compound over all joints of outer panels.

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Last Updated on 2022-11-15

File details come from the government source that posted it. Updated .