516-21-107-CombinedDrawings-Find-LCHCC-EHRM-Upgrades-TMM2139 P1.pdf
PDF 15 MB Posted
- Attached to
- Y1DZ--516-21-107 EHRM Infrastructure Upgrades Construction Lee County VA Clinic (Cape Coral, FL)
- Solicitation number
- 36C77625B0007
About this file
These documents are final construction drawings for the EHRM Infrastructure Upgrades project at the Lee County VA Healthcare Center (HCC) in Cape Coral, Florida, with project number 516-21-107. The comprehensive set of mechanical, electrical, and architectural plans detail infrastructure improvements across four building floors, including telecommunications rooms, electrical rooms, and various medical service areas.
The drawings specify upgrades to HVAC systems, electrical infrastructure, and telecommunications networks, with a focus on supporting the VA's transition to a new Electronic Health Record (EHR) platform. Key elements include installing new fan coil units, reconfiguring telecommunications rooms, upgrading electrical systems with new panels and equipment, and preparing spaces for enhanced technological capabilities. The fully sprinklered facility will feature modernized infrastructure across departments including primary care, surgical specialties, radiology, mental health, and administrative spaces, with detailed plans for each floor's specific technical and medical requirements.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEE COUNTY VA HCC
FINAL DOCUMENTS SUBMITTAL
2489 DIPLOMAT PARKWAY E, CAPE CORAL, FLORIDA 33909
PROJECT No: 516-21-107
SIGNATURE BLOCK
EHRM INFRASTRUCTURE UPGRADES
COVER SHEET
G001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
FINAL DOCUMENTS
SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE UPGRADES
LEE COUNTY VA HCC
CAPE CORAL, FLORIDA
516-21-107
Building No. 1 Project Director
05-31-2024 TS EORevisions: Date:
AutoCAD SHX Text
LOCATION MAP
AutoCAD SHX Text
AREA MAP
AutoCAD SHX Text S
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text O
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text
THOMAS C. STEELE JR.
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text tsteele Text Box
REV. 08-27-24
tsteele Text Box tsteele Line tsteele Text Box tsteele Text Box
REVISIONS TO SHEETS ON 08-27-24
tsteele Text Box tsteele Text Box tsteele Text Box tsteele Text Box
DELETED
tsteele Text Box tsteele Text Box tsteele Text Box tsteele Text Box tsteele Text Box tsteele Text Box
ARCHITECTURAL ABBREVIATIONS
ARCHITECTURAL LEGEND
ARCHITECTURAL GENERAL NOTESGENERAL PROJECT NOTES GENERAL SAFETY NOTES
MATERIAL LEGEND
1.
2.
3.
4.
5.
6.
9.
10.
a.
b.
LEGENDS, ABBREVIATIONS AND
NOTES
G002
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
FINAL DOCUMENTS
SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE UPGRADES
LEE COUNTY VA HCC
CAPE CORAL, FLORIDA
516-21-107
Building No. 1 Project Director
05-31-2024 TS EORevisions: Date:
AutoCAD SHX Text
AIR CONDITIONING
AutoCAD SHX Text
ACOUSTICAL CEILING TILE
AutoCAD SHX Text
ABOVE FINISH FLOOR
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
BOTTOM OF
AutoCAD SHX Text
CEMENTITIOUS BACKER BOARD
AutoCAD SHX Text
CEMENTITIOUS CRYSTALLINE WATERPROOFING
AutoCAD SHX Text
COLD-FORMED METAL FRAMING
AutoCAD SHX Text
CORNER GUARD
AutoCAD SHX Text
CENTERLINE
AutoCAD SHX Text
CERAMIC MOSAIC TILE
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
CASED OPENING
AutoCAD SHX Text
COMMUNICATION
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
CONTRACTING OFFICER'S REPRESENTATIVE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE BASE
AutoCAD SHX Text
CARPET TILE
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
EQUAL
AutoCAD SHX Text
EXPOSED STRUCTURE
AutoCAD SHX Text
ET CETERA
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXPOSED
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FIRE EXTINGUISHER CABINET
AutoCAD SHX Text
FIRE HOSE CABINET
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
FACE OF
AutoCAD SHX Text
FIELD VERIFY (PRIOR TO ORDERING OR CUTTING)
AutoCAD SHX Text
FABRIC WALLCOVERING
AutoCAD SHX Text
GAGE
AutoCAD SHX Text
GYPSUM WALL BOARD
AutoCAD SHX Text
HANDICAPPED
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HIGH-PRESSURE DECORATIVE LAMINATE
AutoCAD SHX Text
HEATING VENTILATION AND AIR-CONDITIONING
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MASONRY OPENING
AutoCAD SHX Text
METAL
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
OPPOSITE HAND
AutoCAD SHX Text
PORCELAIN BASE
AutoCAD SHX Text
PLASTIC LAMINATE
AutoCAD SHX Text
PRESSURE TREATED
AutoCAD SHX Text
PAIR
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
QUARRY TILE
AutoCAD SHX Text
RESILIENT BASE
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
RESINOUS FLOORING
AutoCAD SHX Text
RESINOUS EPOXY WALL - CEILING
AutoCAD SHX Text
ROUGH OPENING
AutoCAD SHX Text
RUBBER FLOORING
AutoCAD SHX Text
SEALED HIGH BUILD GLAZED COATING
AutoCAD SHX Text
SOLID CORE WOOD
AutoCAD SHX Text
SIMILAR
AutoCAD SHX Text
SPECIAL FACED
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
SUBSTRATE
AutoCAD SHX Text
SHEET VINYL
AutoCAD SHX Text
SOLID VINYL TILE
AutoCAD SHX Text
TO BE DETERMINED
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
TOP OF
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text
VINYL COMPOSITION TILE
AutoCAD SHX Text
VINYL WALL COVERING
AutoCAD SHX Text
WALL COVERING
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
WELDED SEAM SHEET FLOORING
AutoCAD SHX Text
AC
AutoCAD SHX Text
ACT
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
BATT
AutoCAD SHX Text
BO
AutoCAD SHX Text
CBB
AutoCAD SHX Text
CCW
AutoCAD SHX Text
CFMF
AutoCAD SHX Text
CG
AutoCAD SHX Text C
AutoCAD SHX Text
CMT
AutoCAD SHX Text
CMU
AutoCAD SHX Text
CO
AutoCAD SHX Text
COMM
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONT
AutoCAD SHX Text
COR
AutoCAD SHX Text
CT
AutoCAD SHX Text
CTB
AutoCAD SHX Text
CT
AutoCAD SHX Text
DIA
AutoCAD SHX Text
EWC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
EQ
AutoCAD SHX Text
ES
AutoCAD SHX Text
ETC
AutoCAD SHX Text
EXIST
AutoCAD SHX Text
EXP
AutoCAD SHX Text
FD
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FF
AutoCAD SHX Text
FIN
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FO
AutoCAD SHX Text
FV
AutoCAD SHX Text
FWC
AutoCAD SHX Text
GA
AutoCAD SHX Text
GWB
AutoCAD SHX Text
HC
AutoCAD SHX Text
HM
AutoCAD SHX Text
HPDL
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
MATL
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MO
AutoCAD SHX Text
MTL
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NTS
AutoCAD SHX Text
OC
AutoCAD SHX Text
OH
AutoCAD SHX Text
PB
AutoCAD SHX Text
PLAM
AutoCAD SHX Text
PT
AutoCAD SHX Text
PR
AutoCAD SHX Text P
AutoCAD SHX Text
QT
AutoCAD SHX Text
RB
AutoCAD SHX Text
REF
AutoCAD SHX Text
REQ'D
AutoCAD SHX Text
RES
AutoCAD SHX Text
RES-W
AutoCAD SHX Text
RO
AutoCAD SHX Text
RF
AutoCAD SHX Text
SC
AutoCAD SHX Text
SCW
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SP
AutoCAD SHX Text
SS
AutoCAD SHX Text
STL
AutoCAD SHX Text
SUBS
AutoCAD SHX Text
SV
AutoCAD SHX Text
SVT
AutoCAD SHX Text
TBD
AutoCAD SHX Text
TELE
AutoCAD SHX Text
TO
AutoCAD SHX Text
TYP
AutoCAD SHX Text
UNO
AutoCAD SHX Text
VCT
AutoCAD SHX Text
VWC
AutoCAD SHX Text
WC
AutoCAD SHX Text
WD
AutoCAD SHX Text
WSF
AutoCAD SHX Text L
AutoCAD SHX Text
SEALED CONCRETE
AutoCAD SHX Text
SCONC
AutoCAD SHX Text
PORCELAIN TILE
AutoCAD SHX Text
POR
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
CJ
AutoCAD SHX Text
GALVANIZED METAL STUD(S)
AutoCAD SHX Text
GMS
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text
RCP
AutoCAD SHX Text
LUXURY VINYL TILE
AutoCAD SHX Text
LVT
AutoCAD SHX Text
COMPOUNDING ASEPTIC CONTAINMENT ISOLATOR
AutoCAD SHX Text
CACI
AutoCAD SHX Text
SOLID SURFACE MATERIAL
AutoCAD SHX Text
SSM
AutoCAD SHX Text
WALL PROTECTION
AutoCAD SHX Text
WP
AutoCAD SHX Text A
AutoCAD SHX Text + 0'-6"
AutoCAD SHX Text
ROOM NAME AND NUMBER
AutoCAD SHX Text
KEY NOTE
AutoCAD SHX Text
PARTITION TYPE
AutoCAD SHX Text
DETAIL CALLOUT
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
SHEET WHERE DETAIL IS DRAWN
AutoCAD SHX Text
SECTION CALLOUT
AutoCAD SHX Text
VERTICAL ELEVATION
AutoCAD SHX Text
COLUMN CENTERLINE DESIGNATION
AutoCAD SHX Text
DEMOLITION NOTE
AutoCAD SHX Text
SECTION NUMBER
AutoCAD SHX Text
SHEET WHERE SECTION IS DRAWN
AutoCAD SHX Text
EXTERIOR ELEVATION CALLOUT
AutoCAD SHX Text
ELEVATION NUMBER
AutoCAD SHX Text
SHEET WHERE ELEVATION IS DRAWN
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
NAME
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text A301
AutoCAD SHX Text
AutoCAD SHX Text A201
AutoCAD SHX Text
AutoCAD SHX Text
GA4
AutoCAD SHX Text
INTERIOR ELEVATION CALLOUT
AutoCAD SHX Text
ELEVATION NUMBER
AutoCAD SHX Text
SHEET WHERE ELEVATION IS DRAWN
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO: DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO: FACE OF EXISTING WALL SURFACE FACE OF NEW MASONRY FACE OF NEW WALL STUDS TOP OF SLAB TOP OF MASONRY ALIGN NEW WALLS WITH EXISTING WHERE NOT OTHERWISE INDICATED. B. COORDINATE WITH ALL DISCIPLINE DRAWINGS FOR COORDINATE WITH ALL DISCIPLINE DRAWINGS FOR ADDITIONAL REQUIREMENTS. COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE NEW HOLES IN EXISTING WALLS AND SLABS ARE CREATED FOR CONDUIT, DUCT, OR PIPE PENETRATIONS, COORDINATE SIZE AND LOCATION. PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLES, ETC. WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE, MATERIAL, THICKNESS, ALIGNMENT, GRADES, AND QUALITY. PATCH OR SEAL EXISTING HOLES IN WALLS AND GLASS TO MATCH ADJACENT EXISTING MATERIALS. C. COORDINATE AND PROVIDE SOLID FIRE RETARDANT TREATED COORDINATE AND PROVIDE SOLID FIRE RETARDANT TREATED WOOD BLOCKING FOR WALL-MOUNTED ITEMS BETWEEN STUDS. COORDINATE LOCATIONS WITH COR FOR GOVERNMENT FURNISHED EQUIPMENT. D. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING, INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED. E. SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SMOKE RATED PARTITIONS AND FIRE-RATED PARTITIONS WITH THE APPROPRIATE FIRESTOP TO MAINTAIN THE RATING OF THE WALL OR SLAB. SUBMIT CUT SHEETS AND SPECIFICATIONS TO THE COR FOR APPROVAL PRIOR TO INSTALLATION. PROVIDE UL LISTED ASSEMBLIES. F. PATCH ALL DAMAGED EXISTING WALL AND CEILING PATCH ALL DAMAGED EXISTING WALL AND CEILING SURFACES THAT REQUIRE PAINTING TO MATCH ADJACENT SURFACES. G. REMOVED MATERIALS WHICH ARE INDICATED TO BE TURNED REMOVED MATERIALS WHICH ARE INDICATED TO BE TURNED OVER TO THE COR SHALL BE DELIVERED BY THE CONTRACTOR TO A PLACE INDICATED BY THE COR IF APPLICABLE. H. REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR FINISHES. WHERE EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION, FLOORING, ETC.) EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO INSTALLATION OF NEW MATERIALS. I. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST. WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.
AutoCAD SHX Text A. CONTRACTOR SHALL PROVIDE A PHASING AND CONTRACTOR SHALL PROVIDE A PHASING AND CONTAMINATION CONTAINMENT PLAN BEFORE BEGINNING WORK PER VAMC INFECTION CONTROL RISK ASSESSMENT (ICRA) TEAM REQUIREMENTS B. ESTABLISH AND MAINTAIN A DUST CONTROL PROGRAM AS ESTABLISH AND MAINTAIN A DUST CONTROL PROGRAM AS PART OF THE CONTRACTOR'S INFECTION PREVENTATIVE MEASURES IN ACCORDANCE WITH THE GUIDELINES PROVIDED BY THE ICRA TEAM PRIOR TO START OF WORK, PREPARE PLAN DETAILING PROJECT-SPECIFIC DUST PROTECTION MEASURES, INCLUDING PERIODIC STATUS REPORTS, AND SUBMIT TO COR AND FACILITY ICRA TEAM FOR REVIEW OF COMPLIANCE WITH CONTRACT DOCUMENTS. C. ALL PERSONNEL INVOLVED IN THE CONSTRUCTION OR ALL PERSONNEL INVOLVED IN THE CONSTRUCTION OR RENOVATION ACTIVITY SHALL BE EDUCATED AND TRAINED IN INFECTION PREVENTION MEASURES ESTABLISHED BY THE MEDICAL CENTER. D. DUST PRODUCING TASKS SHALL NOT BE PERFORMED DUST PRODUCING TASKS SHALL NOT BE PERFORMED WITHIN OCCUPIED AREAS WITHOUT THE APPROVAL OF THE COR. E. ALL WORK INSIDE BUILDING SHALL BE PERFORMED ON ALL WORK INSIDE BUILDING SHALL BE PERFORMED ON DAYS AND DURING HOURS APPROVED BY THE COR. IN THE INCIDENT OF AN EMERGENCY MEDICAL CASE, THE CONTRACTOR MAY BE REQUIRED TO CEASE WORK AND CLEAN UP IMMEDIATELY. CONTRACTOR SHALL NOTIFY COR IMMEDIATELY IF ASKED TO CEASE OR ALTER THEIR PLANNED WORK. F. BASED ON PROJECT SCOPE, OFF-HOUR TEMPORARY BASED ON PROJECT SCOPE, OFF-HOUR TEMPORARY CONSTRUCTION BARRIER ERECTION AND DEMO/NEW WORK CONSTRUCTION MAY BE REQUIRED. WORK SHALL BE INCLUSIVE OF THE CONTRACTOR AND SUB-CONTRACTORS SCOPE / BASE CONTRACT WORK AT NO ADDITIONAL COST TO THE VA. G. REFER TO SPEC 013526 FOR INFECTION CONTROL REFER TO SPEC 013526 FOR INFECTION CONTROL REQUIREMENTS. H. ALL TR & DATA ROOM EQUIPMENT WILL BE REMOVED OR ALL TR & DATA ROOM EQUIPMENT WILL BE REMOVED OR COVERED BY VA. CONTRACTOR IS RESPONSIBLE FOR REPAIR COST OF ANY DAMAGED EXISTING xxxxxx ROOM EQUIPMENT. I. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR EQUIPMENT UNTIL SUBMITTALS FOR SUCH HAVE BEEN APPROVED. J. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR EACH MEMBER OF HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED TO RECEIVE BADGES. COORDINATE WITH COR. K. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE, DUST, AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL ALARM. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH COR. ALL FIRE ALARM DEVICES SHALL BE ACTIVE WHENEVER CONTRACTOR'S FORCES ARE NOT PRESENT IN WORK AREA. L. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING OFFICER. M. SEE SPECIFICATION SECTIONS 01 00 00 AND 01 35 26 SEE SPECIFICATION SECTIONS 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES. N. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & ALL CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. EXISTING CONDITIONS ARE BASED ON GOVERNMENT FURNISHED EXISTING DRAWINGS AND LIMITED FIELD INVESTIGATION. NOTIFY COR OF ANY DISCREPANCIES PRIOR TO PROCEEDING. O. ALL FINISH COLORS TO BE SELECTED BY COR WHERE NOT ALL FINISH COLORS TO BE SELECTED BY COR WHERE NOT OTHERWISE INDICATED. P. SEAL ALL CEILING, FLOOR AND WALL PENETRATIONS SEAL ALL CEILING, FLOOR AND WALL PENETRATIONS AROUND CONDUIT AND PIPES - TYPICAL.
AutoCAD SHX Text
EARTH
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
MORTAR, STUCCO CEMENT PLASTER
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
INSULATION RIGID
AutoCAD SHX Text
INSULATION BATT
AutoCAD SHX Text
BRICK
AutoCAD SHX Text
WOOD (ROUGH)
AutoCAD SHX Text
WOOD FINISH
AutoCAD SHX Text COMPLETE ALL CRITICAL BARRIERS BEFORE CONSTRUCTION BEGINS. INSTALL CONSTRUCTION BARRIERS AND CEILING PROTECTION CAREFULLY, OUTSIDE OF NORMAL WORK HOURS. USE OF TEMPORARY WALL TYPE SYSTEM RECOMMENDED. SEPARATE ALL OCCUPIED AREAS FROM DEMOLITION, RENOVATION, OR CONSTRUCTION ACTIVITIES BY ONE-HOUR FIRE RATED TEMPORARY SMOKE-TIGHT CONSTRUCTION PARTITIONS OF GYPSUM BOARD OR OTHER APPROVED NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. SEPARATION SHALL EXTEND FROM FLOOR TO UNDERSIDE OF DECK ABOVE. POLY BARRIERS MAY BE USED FOR WORK LASTING LESS THAN 48 HOURS. TEMPORARY CONSTRUCTION CONTAINMENT SYSTEMS THAT ARE GASKETED AT TOP AND BOTTOM TO CREATE AN AIRTIGHT SEAL WHICH MEETS OR EXCEEDS ICRA CLASS IV REQUIREMENTS AND EXCEEDS ASTM E-84 CLASS A STANDARDS FOR FLAME AND SMOKE SPREAD SHALL BE USED AS CONSTRUCTION PARTITIONS. SUCH CONSTRUCTION SHALL BE PROVIDED AT ALL LOCATIONS OF ACTIVE CONSTRUCTION, INCLUDING ENTRIES. ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM. CLOSELY COORDINATE WITH VA HVAC SHOPS TO MAINTAIN PROPER FUNCTION OF HVAC SYSTEM. HVAC SYSTEM SHALL BE RESTORED TO NORMAL OPERATION AT THE COMPLETION OF WEEKEND WORK. MAINTAIN NEGATIVE AIR PRESSURE, 0.01 INCHES OF WATER GAUGE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS AND CONTINUOUSLY MONITORED WITH DIGITAL DISPLAY, RECORDING AND ALARM INSTRUMENT, WHICH MUST BE CALIBRATED ON INSTALLATION, MAINTAINED WITH PERIODIC CALIBRATION AND MONITORED BY THE CONTRACTOR. 7. EXHAUST HOSES REQUIRED: HEAVY DUTY, FLEXIBLE STEEL REINFORCED; EXHAUST HOSES REQUIRED: HEAVY DUTY, FLEXIBLE STEEL REINFORCED; VENTILATION BLOWER HOSE. 8. ADHESIVE WALK-OFF MATS SHALL BE USED AT ALL INTERIOR ADHESIVE WALK-OFF MATS SHALL BE USED AT ALL INTERIOR TRANSITIONS FROM THE CONSTRUCTION AREA TO OCCUPIED AREA. PROVIDE MINIMUM SIZE MATS OF 24 INCHES BY 36 INCHES. THESE MATS SHALL BE CHANGED AS OFTEN AS REQUIRED TO MAINTAIN CLEAN WORK AREAS DIRECTLY OUTSIDE CONSTRUCTION AREA AT ALL TIMES. VACUUM AND WET MOP ALL TRANSITION AREAS FROM CONSTRUCTION TO THE OCCUPIED MEDICAL CENTER AT THE END OF EACH WORKDAY. VACUUM SHALL UTILIZE HEPA FILTRATION. MAINTAIN SURROUNDING AREA FREQUENTLY. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS. 11. MODIFY/REMOVE EXISTING CEILING CONSTRUCTION AS REQUIRED TO MODIFY/REMOVE EXISTING CEILING CONSTRUCTION AS REQUIRED TO ACCOMMODATE TEMPORARY PARTITIONS. STORE ALL ACOUSTICAL CEILING PANELS, GRID, LIGHT FIXTURES AND CEILING ACCESSORIES AS DIRECTED BY THE VA. WHERE EXISTING CEILINGS ARE TO REMAIN, THEY ARE TO BE RESTORED TO ORIGINAL CONDITION AFTER REMOVAL OF TEMPORARY PARTITIONS. 12. MODIFY EXISTING MEP/FP (INCLUDING BUT NOT LIMITED TO, DIFFUSERS MODIFY EXISTING MEP/FP (INCLUDING BUT NOT LIMITED TO, DIFFUSERS AND REGISTERS, LIGHT FIXTURES, SPRINKLER HEADS) AS REQUIRED TO MAINTAIN APPROPRIATE COVERAGE/LIGHTING/SERVICE TO ALL OCCUPIED SPACES DURING CONSTRUCTION ACTIVITIES. RESTORE ALL INFRASTRUCTURE TO ORIGINAL CONDITION AFTER REMOVAL OF TEMPORARY PARTITIONS. 13. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL PUBLIC SPACES CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL PUBLIC SPACES AT AREAS OF CONSTRUCTION. CONTRACTOR SHALL PATCH, REPAIR, PAINT, RESTORE, REPLACE CONSTRUCTION DAMAGED MATERIALS IN PUBLIC SPACES TO MATCH EXISTING CONDITIONS AS PART OF THE PROJECT'S SCOPE/BASE CONTRACT WORK AT NO ADDITIONAL COST TO THE PROJECT/GOVERNMENT. 14. UPON COMPLETION: UPON COMPLETION: a. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS INSPECTED BY THE COR AND THOROUGHLY CLEANED BY THE VA ENVIRONMENTAL SERVICES DEPARTMENT. b. REMOVE CONSTRUCTION BARRIERS AND CEILING PROTECTION REMOVE CONSTRUCTION BARRIERS AND CEILING PROTECTION CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION, OUTSIDE OF NORMAL WORK HOURS. c. REMOVE ALL CONSTRUCTION DEBRIS FROM ABOVE CEILING / VERTICAL REMOVE ALL CONSTRUCTION DEBRIS FROM ABOVE CEILING / VERTICAL SHAFTS AND AND UTILITY CHASES THAT HAVE BEEN PART OF CONSTRUCTION. d. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS. e. WET MOP AREA WITH CLEANER/DISINFECTANT. WET MOP AREA WITH CLEANER/DISINFECTANT. f. UPON COMPLETION, RESTORE HVAC SYSTEM WHERE WORK WAS UPON COMPLETION, RESTORE HVAC SYSTEM WHERE WORK WAS PERFORMED. 15. SPRINKLER AND FIRE ALARM ARE TO REMAIN ACTIVE THROUGHOUT PROJECT. TEMPORARY PROTECTION MUST BE PROVIDED IF FIRE ALARM SYSTEM IS DOWN FOR MORE THAN 8 HRS. OR SPRINKLER SYSTEM IS DOWN FOR MORE THAN 10 HRS. 16. IF THERE WILL BE A LAYDOWN AREA: PROVIDE SECURED PERIMETER PROTECTION CONSISTING OF A 7' MIN. HEIGHT CHAIN LINK FENCING WITH LOCKABLE GATE AROUND ALL STORED MATERIALS, SCAFFOLDING, EQUIPMENT, ETC. THESE AREAS ARE TO REMAIN SECURED AT ALL TIMES, INCLUDING WHILE AREA IS OCCUPIED. SITE AND LAYDOWN AREA MUST REMAIN SECURED BY LOCK AND KEY AT ALL TIMES. 17. SHOE COVERS, HEAD COVERING AND SCRUBS/CLEAN SUITS SHALL BE WORN BY ALL CONTRACTOR PERSONNEL IF REQUESTED BY THE COR. CONTRACTOR SHALL PROVIDE ALL PERSONAL PROTECTION EQUIPMENT.
AutoCAD SHX Text S
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text O
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text
THOMAS C. STEELE JR.
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
SIGNAL
1B-191
SIGNAL
1A-139
CRAC
DRY AGENT TANK
CRAC
SERVERS SERVERSSERVERS
ROUTERSDATA
SWITCHES
"B" FO PATH
LIU/PP
"A" FO PATH
LIU/PP
S
TELECOMMUNICATIONS ROOM
PLANS
AE-101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
FINAL DOCUMENTS
SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE UPGRADES
LEE COUNTY VA HCC
CAPE CORAL, FLORIDA
516-21-107
Building No. 1 Project Director
05-31-2024 TS EORevisions: Date:
AutoCAD SHX Text
TR
AutoCAD SHX Text 1B-190
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_1B-190
AutoCAD SHX Text H
AutoCAD SHX Text
RUN AND TERMINATE NEW A/B FO CABLE TO EXISTING DATA SWITCH
AutoCAD SHX Text
TR
AutoCAD SHX Text 1A-208
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM TR_1A-208
AutoCAD SHX Text 14.6
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text 1B-118
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM_TR_1B-118
AutoCAD SHX Text U
AutoCAD SHX Text
RUN AND TERMINATE NEW A/B FO CABLE TO EXISTING DATA SWITCH
AutoCAD SHX Text
TR
AutoCAD SHX Text 1A-138
AutoCAD SHX Text L.5
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_1A-138
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text 2A-136
AutoCAD SHX Text
CORR.
AutoCAD SHX Text C2-43
AutoCAD SHX Text
SIGNAL
AutoCAD SHX Text 2A-137
AutoCAD SHX Text L.5
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_2A-136
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text 2B-146
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_2B-146
AutoCAD SHX Text U
AutoCAD SHX Text
TR
AutoCAD SHX Text 2B-199
AutoCAD SHX Text
SIGNAL
AutoCAD SHX Text 2B-201
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_2B-199
AutoCAD SHX Text J
AutoCAD SHX Text H
AutoCAD SHX Text
RUN AND TERMINATE NEW A/B FO CABLE TO EXISTING DATA SWITCH
AutoCAD SHX Text
TR
AutoCAD SHX Text 3A-150
AutoCAD SHX Text
SIGNAL
AutoCAD SHX Text 3A-151
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_3A-150
AutoCAD SHX Text
AutoCAD SHX Text L.5
AutoCAD SHX Text
IRMS DATA
AutoCAD SHX Text
/TELE. EQ.
AutoCAD SHX Text 4A-142
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text 4A-103
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
DATA CENTER RM_DCR_4A-142
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text J.5
AutoCAD SHX Text L
AutoCAD SHX Text
2 EA 4" EMPTY CONDUIT - SERVICE ENTRANCE FROM VAULT AT CORBETT ROAD VIA 3A-150
AutoCAD SHX Text 2 EA 4" CONDUIT - AT&T & CENTURY LINK SERVICE ENTRANCE FIBER OPTIC CABLE & CU VOICE FROM VAULT AT DIPLOMAT PKWY VIA 4A-154
AutoCAD SHX Text 2 EA 4" CONDUIT SLEEVES - NEW 24S OM4, 12S 0S2 FIBER OPTIC "A" & "B" PATH CABLE TO ALL TRS
AutoCAD SHX Text
TR
AutoCAD SHX Text 4A-154
AutoCAD SHX Text
SIGNAL
AutoCAD SHX Text 4A-152
AutoCAD SHX Text
AE-101
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
TELECOM RM_TR_4A-154
AutoCAD SHX Text
AutoCAD SHX Text L.5
AutoCAD SHX Text
RUN AND TERMINATE NEW A/B FO CABLE TO EXISTING DATA SWITCH
AutoCAD SHX Text
EXISTING CONSTRUCTION TO REMAIN
AutoCAD SHX Text
PLAN LEGEND
AutoCAD SHX Text
NEW CONSTRUCTION
AutoCAD SHX Text
EXIST SMOKE PARTITION
AutoCAD SHX Text
EXIST 1-HOUR FIRE PARTITION
AutoCAD SHX Text
EXIST 2-HOUR FIRE PARTITION
AutoCAD SHX Text
EXIST 1-HOUR RATED SMOKE WALL
AutoCAD SHX Text FLOOR PLAN GENERAL NOTES A. TOUCH UP FINISHES AS NEEDED AFTER TOUCH UP FINISHES AS NEEDED AFTER COMPLETION OF WORK. B. DIMENSIONS AT EXISTING CONSTRUCTION ARE TO DIMENSIONS AT EXISTING CONSTRUCTION ARE TO FACE OF EXISTING FINISH OR COLUMN UNO. C. DIMENSIONS AT NEW CONSTRUCTION ARE TO FACE DIMENSIONS AT NEW CONSTRUCTION ARE TO FACE OF STUD OR MASONRY. D. NEW PARTITIONS WHICH FALL ON COLUMN LINES NEW PARTITIONS WHICH FALL ON COLUMN LINES ARE CENTERED ON COLUMN LINES UNO. E. SEE TELECOMMUNICATION SHEET TA401 FOR SEE TELECOMMUNICATION SHEET TA401 FOR EQUIPMENT INFORMATION. F. PAINT ALL WALLS IN THE TELECOM ROOMS AND PAINT ALL WALLS IN THE TELECOM ROOMS AND DATA CENTER ROOM. G. CLEAN ALL WOOD DOORS. PAINT ALL DOOR CLEAN ALL WOOD DOORS. PAINT ALL DOOR FRAMES AND METAL DOORS.
AutoCAD SHX Text
ARCHITECTURAL FLOOR PLAN KEY NOTES (ALL NOTES NOT USED ON ALL SHEETS)
AutoCAD SHX Text
EXISTING EQUIPMENT TO REMAIN
AutoCAD SHX Text
FOR EQUIPMENT QUANTITIES AND GENERAL PLACEMENT, SEE SHEET TA-401
AutoCAD SHX Text S
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text O
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text
THOMAS C. STEELE JR.
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
TH
S
DIS
T
H
CO2
CO
HS
NO2
PS
BT TM
PIPING SYMBOLS AND ABBREVIATIONSHVAC SYMBOLS AND ABBREVIATIONS
22"x8"
22"/8"
22"Ø
EXISTING DUCT TAG
OVAL DUCT SIZE TAG (WIDTH / HEIGHT)
SQUARE DUCT SIZE TAG (WIDTH x HEIGHT)
ROUND DUCT SIZE TAG (DIAMETER)
DUCT BEING DEMOLISHED
(E)22"Ø
RECTANGULAR SUPPLY/OUTSIDE AIR
DUCT RISE
RECTANGULAR RETURN/TRANSFER AIR
DUCT RISE
ROUND SUPPLY/OUTSIDE AIR DUCT RISE
ROUND RETURN/TRANSFER AIR DUCT RISE
RECTANGULAR EXHAUST/RELIEF AIR
DUCT RISE
DROP
DROP
DROP
DROP
DROP
DROP ROUND EXHAUST/RELIEF AIR DUCT RISE
CONTINUATION SYMBOL
NUMBER OF SHEET WHERE DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
REVISION NUMBER - SHOWN ON PLANS
GENERAL MECHANICAL SYMBOLS
ROOM NAME AND NUMBER
CONNECT NEW TO EXISTING
EXISTING PIPE TAG
AREA NOT IN CONTRACT
PIPING BEING DEMOLISHED
PIPE SIZE TAG (DIAMETER)
Room
LIMIT OF DEMOLITION
NEW WORK NOTES
DEMOLISHED WORK NOTES
ACCESS DOOR ON TOP OF DUCT
ACCESS DOOR ON SIDE OF DUCT
ACCESS DOOR ON BOTTOM OF DUCT
SHEET NOMENCLATURE
M P # # #
SERIES
MECHANICAL
(S) STEAM
(H) HVAC
(P) PIPING
(D) DEMO
SERIES
0 - SYMBOLS AND NOTES
1 - PLAN VIEWS
3 - ELEVATIONS AND SECTIONS
4 - LARGE SCALE - PLANS AND SECTIONS
5 - SCHEMATICS AND DETAILS
6 - SCHEDULES
8 - CONTROLS
FD
SD
AVD
MVD
BDD
FSD
48"x2 1/2" D
(E)LINEAR BAR
GRILLE
(E)RTU-XX
(E)TU-XX
EQUIPMENT
TAG
EQUIPMENT TAG
VAV TERMINAL
MANUAL BALANCING
DAMPER
BACKDRAFT DAMPER
COMBINATION
FIRE/SMOKE
DAMPER
FIRE DAMPER
SMOKE DAMPER
AUTOMATIC VOLUME
DAMPER
SYMBOL
TYPE (SEE SCHEDULE)
CFM
ACTIVE SLOT LENGTH
(PLENUM LENGTH)
GRILLES, REGISTERS & DIFFUSERS TAG
DAMPER TAGS AND ABBREVIATIONS
IRH INFRARED HEATER
IU INDUCTION UNIT
JB JUNCTION BOX
JL JUSTIFIED LEFT
JR JUSTIFIED RIGHT
KG KILOGRAM
KG/HR KILOGRAM PER HOUR
kPa KILOPASCAL
KW KILOWATT
KWH KILOWATT HOUR
LOOP LOCK ONLY OPEN POSITION
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M METER, SI UNIT
M/S METERS PER SECOND
(OR METERS/SECOND)
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1,000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING
VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOCP MINIMUM OVERCURRENT PROTECTION
MOV MOTOR OPERATED VALVE
MTD MEAN TEMPERATURE DIFFERENCE
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NO NORMALLY OPEN
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NPSHA NET POSITIVE SUCTION HEAD
AVAILABLE
NPSHR NET POSITIVE SUCTION HEAD
REQUIRED
NTS NOT TO SCALE
OA OUTSIDE AIR
OAD OUTDOOR AIR DAMPER
OD OUTSIDE DIAMETER
P PUMP
Pa PASCAL
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PF PRE-FILTER
PG PRESSURE GAGE
PHC PREHEAT COIL
PPM PARTS PER MILLION
PRS PRESSURE REGULATING (VALVE)
STATION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH –
ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PTAC PACKAGED TERMINAL AIR
CONDITIONER
QNTY QUANTITY
RA RETURN AIR
RAF RETURN AIR FAN
RAT RETURN AIR TEMPERATURE
RD REFRIGERANT DISCHARGE
REA RELIEF AIR
RF RETURN FAN
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RS/RL REFRIGERANT SUCTION AND
REFRIGERANT LIQUID
RTU ROOF TOP UNIT
RV RELIEF VALVE
SA SUPPLY AIR
SAT SUPPLY AIR TEMPERATURE
SCFM STANDARD CUBIC FEET PER MINUTE
SCR SILICON CONTROLLED RECTIFIER
SEA SMOKE EXHAUST AIR
SEN SENSIBLE HEAT
SF SUPPLY FAN
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SS STAINLESS STEEL
SSR SOLID SEPARATOR
ST STEAM TRAP
TAB TESTING, ADJUSTING, BALANCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
UC UNDER CUT
UH UNIT HEATER
V VENT
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VP VACUUM PUMP
VR VACUUM (STEAM CONDENSATE)
RETURN
W WATTS
Wb WET-BULB (TEMPERATURE)
WFMS WATER FLOW MEASURING STATION
WG WATER GAGE
WPD WATER PRESSURE DROP
YR YEAR
EJ EXPANSION JOINT
ENT ENTERING
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
FA FREE AREA
FCU FAN COIL UNIT
FD FLOOR DRAIN
FF FINAL FILTER
FM FLOW METER
FOP FUEL OIL PUMP
FOT FLAT ON TOP
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPU FAN POWERED TERMINAL UNIT
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
FT FEET
FT WC FEET OF WATER COLUMN
FT-LB FOOT-POUND
FV FACE VELOCITY
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
H HUMIDIFIER
HB HOSE BIBB
HC HEATING COIL
HD HOOD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HRC HEAT RECOVERY COIL
HRP HYDRONIC RADIANT (CEILING) PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HVU HEATING AND VENTILATING UNIT
HWC HOT WATER COIL
HWP HEATING HOT WATER PUMP
HTX HEAT EXCHANGER
HZ HERTZ
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
IPLV INTEGRATED PART LOAD VALUE
A/E ARCHITECT / ENGINEER
AAV AUTOMATIC AIR VENT
ACD AUTOMATIC CONTROL DAMPER
AD ACCESS DOOR
AF AFTER FILTER
AFF ABOVE FINISHED FLOOR
AFMS AIR FLOW MEASURING STATION
AHU AIR-HANDLING UNIT
AMP AMPERE
APD AIR PRESSURE DROP
AS AIR SEPARATOR
B BOILER
BAS BUILDING AUTOMATION SYSTEM
BBR BASE BOARD RADIATOR
BE BOTTOM ELEVATION
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CV CONSTANT AIR VOLUME
CC COOLING COIL
CD COOLING COIL CONDENSATE DRAIN
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CH CHILLER
CHP CHILLED WATER PUMP
CHS/R CHILLER WATER
CL CENTER LINE
CM CUBIC METER
CM/S CUBIC METER PER SECOND
CO CLEAN OUT
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
COR CONTRACTING OFFICER
REPRESENTATIVE
CP CONDENSATE PUMP
CST CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CWP CONDENSER WATER PUMP
DDC DIRECT DIGITAL CONTROLS
DIA DIAMETER
DI DEIONIZED WATER
DP DEW POINT TEMPERATURE
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
ES EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
PROJECT ABBREVIATIONS
DATA DEVICE TAGS AND ABBREVIATIONS
MECHANICAL EQUIPMENT TAGS
CONDENSER WATER SUPPLY (FROM TOWER)
CONDENSER WATER RETURN (TO TOWER)
HOT WATER HEATING SUPPLY
HOT WATER HEATING RETURN
LOW PRESSURE STEAM (15 PSIG AND BELOW)
LOW PRESSURE STEAM CONDENSATE RETURN
MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)
MEDIUM PRESSURE STEAM CONDENSATE RETURN
PUMPED CONDENSATE DISCHARGE
HIGH PRESSURE STEAM (60 PSIG AND ABOVE)
MEDIUM PRESSURE STEAM CONDENSATE RETURN
GLYCOL-WATER HEATING SUPPLY
GLYCOL-WATER HEATING RETURN
STEAM VENT PIPE
REFRIGERANT SUCTION AND REFRIGERANT LIQUID
CHILLED WATER SUPPLY
CHILLED WATER RETURN
MAKE-UP WATER
DRAIN PIPING
CONDENSATE DRAIN
FEEDWATER PUMP DISCHARGE
FEEDWATER PUMP SUCTION
CONDENSATE TRANSFER PUMP DISCHARGE
CONDENSATE TRANSFER PUMP SUCTION
CONTINUOUS BLOWDOWN
BOILER WATER SAMPLE
BOILER BLOWOFF
FEEDWATER SAMPLE (FROM DEAERATOR)
OVERFLOW
COMPRESSED AIR
NATURAL GAS MAIN FUEL
NATURAL GAS IGNITER FUEL
FUEL OIL SUPPLY
FUEL OIL RETURN
SOFTENED WATER
SUPPLY
DIFFUSER
NECK SIZE
CFM
RETURN
GRILLE
EXHAUST
GRILLE
AD
DOMESTIC COLD WATER
DOMESTIC HOT WATER
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER
DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS
SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
NITROGEN DIOXIDE SENSOR
HUMIDITY SENSOR
HUMIDISTAT
TEMPERATURE & HUMIDITY
SENSOR
DISPLAY
THERMOSTAT
SENSOR
PRESSURE SENSOR
DESCRIPTION DESCRIPTION
RTU-XX
TU-XX
6"Ø A
8"Ø
B
6"x6" C
NECK SIZE
CFM
NECK SIZE
CFM
LPS
LPR
MPS
MPR
HPS
HPR
PCD
SV
HWS
GHS
HWR
GHR
RS/RL
CWS
CWR
CHS
CHR
MW
D
CD
FWPD
FWPS
CTPD
CTPS
BO
CBD
BWS
FWS
OFL
A
G
G(I)
FOS
FOR
SW
DCW
DHW
(E) 2"
(E) 2"
BASE STATION TRANSMITTER TEMPERATURE AND HUMIDITY
RACK MONITORING
GENERAL PIPING SYMBOLS
DIRECTION OF PIPE PITCH (DOWN)
DIRECTION OF FLOW
ANCHOR
REDUCER OR INCREASER
ECCENTRIC REDUCER
TOP CONNECTION, 45° OR 90°
BOTTOM CONNECTION, 45° OR 90°
SIDE CONNECTION
CAPPED OUTLET
RISE OR DROP IN PIPE
PIPE UP
PIPE DOWN
INVERTED BUCKET TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
THERMOSTATIC TRAP SET INCLUDING PIPING
ACCESSORIES SEE DETAIL
THERMOMETER
PRESSURE GAGE
VENTURI FLOW METER
REFRIGERANT SIGHT GLASS
TEST PLUG (PRESSURE/TEMPERATURE)
UNION
AUTOMATIC AIR VENT
MANUAL AIR VENTMV
QUICK-COUPLE HOSE CONNECTOR
SYMBOLS SYMBOLS NAME
LC
M
VALVE SYMBOLS AND ABBREVIATIONS
SCHEMATIC VIEW ELEVATION VIEW NAME AND ABBREVIATIONS
GATE VALVE - GV
GLOBE VALVE - GLBV
CHECK VALVE - CV
ANGLE GLOBE VALVE - AGLBV
BUTTERFLY VALVE - BFV
BALL VALVE - BV
THREE WAY VALVE - TWV
PRESSURE REGULATING VALVE - PRV
PRESSURE SAFETY VALVE - PSV
PLUG VALVE - PV
WYE STRAINER
WYE STRAINER (WITH BALL VALVE
AND HOSE CONNECTION)
WYE STRAINER WITH VALVED DRAIN
AND QUICK-COUPLE HOSE CONNECTOR
FLEXIBLE CONNECTION
MODULATING CONTROL VALVE
MODULATING CONTROL BUTTERFLY
VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL
VALVE
THREE-WAY TWO POSITION CONTROL
VALVE
AUTOMATIC BALANCING CONTROL
VALVE
CIRCUIT SETTER VALVE
WATER BALANCE DEVICE
GATE VALVE WITH GLOBE-VALVED
BYPASS
CONTROL VALVE (CV) - FLOAT-
OPERATED
WATER LEVEL CONTROLLER
FLOW METER
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
Building No. 1
Cape Coral, Florida
M001
516-21-107
JMK JSW/RCP05-31-2024
MECHANICAL LEGEND, ABBREVIATIONS,
AND NOTES
EHRM Infrastructure Upgrades - Lee County VA
HCC
FINAL DOCUMENTS
SUBMITTAL
HVAC SHEET INDEX
SHEET
NUMBER DRAWING TITLE
M001 MECHANICAL LEGEND, ABBREVIATIONS, AND NOTES
M002 MECHANICAL NOTES
M101 FIRST FLOOR OVERALL PLAN
M102 SECOND FLOOR OVERALL PLAN
M103 THIRD FLOOR OVERALL PLAN
M104 FOURTH FLOOR OVERALL PLAN
MH401 FIRST FLOOR - TR-1A-138 AND TR-1A-208 - ENLARGED HVAC PLANS
MH402 FIRST FLOOR - TR-1B-118 AND TR-1B-190 - ENLARGED HVAC PLANS
MH403 SECOND FLOOR - TR-2A-136, TR - 2B-146 AND TR-2B-199 - ENLARGED HVAC PLANS
MH404 THIRD FLOOR - TR-3A-150 - ENLARGED HVAC PLANS
MH405 FOURTH FLOOR - TR-4A-154 - ENLARGED HVAC PLANS
MP401 FIRST FLOOR - TR-1A-138 AND TR-1A-208 - ENLARGED PIPING PLANS
MP402 FIRST FLOOR - TR-1B-118 AND TR-1B-190 - ENLARGED PIPING PLANS
MP403 SECOND FLOOR - TR-2A-136 - ENLARGED PIPING PLANS
MP404 SECOND FLOOR - TR-2B-146 AND TR-2B-199 - ENLARGED PIPING PLANS
MP405 THIRD FLOOR - TR-3A-150 - ENLARGED PIPING PLANS
MP406 FOURTH FLOOR - TR-4A-154 - ENLARGED PIPING PLANS
M501 MECHANICAL DETAILS, HVAC SCHEDULES AND CONTROL SCHEDULES AND NOTES
P
R O
FESS I ONA L ENG
I N E
E R
JE
REM
Y M. KNOWLESL I C E NS E
F L O R I D A
No. 90210
STATE OF
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
MECHANICAL NOTES EHRM Infrastructure Upgrades - Lee County VA HCC
Cape Coral, Florida
M002
516-21-107
JMK JSW05-31-2024
FINAL DOCUMENTS
SUBMITTAL
A. THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS, BOTH
EXISTING AND THOSE ILLUSTRATED BY THESE DOCUMENTS, AS WELL AS
THOSE WHICH CAN BE REASONABLY ANTICIPATED INCLUDING, BUT NOT
LIMITED TO ARCHITECTURAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND
OTHER SYSTEMS INVOLVED ON THIS PROJECT.
B. FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM AND
SHALL CONFORM TO ALL CURRENT REQUIREMENTS FOUND IN THE UNITED
STATES DEPARTMENT OF VETERANS AFFAIRS TECHNICAL INFORMATION
LIBRARY, INCLUDING BUT NOT LIMITED TO THE PHYSICAL SECURITY MANUAL,
HVAC DESIGN MANUAL, AND STEAM, HEATING HOT WATER, AND OUTSIDE
DISTRIBUTION SYSTEM DESIGN MANUAL. ALL WORK SHALL ALSO CONFORM
TO ALL FEDERAL, STATE, AND LOCAL CODES, INCLUDING BUT NOT LIMITED TO
THE INTERNATIONAL BUILDING CODE AND INTERNATIONAL MECHANICAL
CODE.
C. INSTALL ALL EQUIPMENT AND DEVICES IN ACCORDANCE WITH THEIR
RESPECTIVE MANUFACTURER’S INSTALLATION INSTRUCTIONS AT A LEVEL OF
QUALITY AND WORKMANSHIP CONSISTENT WITH THESE DOCUMENTS. ANY
DEVIATIONS BETWEEN THE INSTALLATION INSTRUCTIONS AND THESE
DOCUMENTS WILL BE BROUGHT TO THE ATTENTION TO THE COR BEFORE ANY
COURSE OF ACTION BY THE CONTRACTOR IS INITIATED, INCLUDING
PURCHASE OF EQUIPMENT.
D. CONTRACTOR SHALL COORDINATE ALL WORK DESCRIBED AND ILLUSTRATED
IN THESE DRAWINGS. LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS
INDICATED ON THESE DRAWINGS ARE APPROXIMATE AND SUBJECT TO
ADJUSTMENTS IN THE FIELD. OFFSET DUCTS, PIPING, AND SHIFT EQUIPMENT
AS REQUIRED TO AVOID INTERFERENCE AND CONFLICTS IN THE FIELD.
COORDINATE DUCT AND PIPE ROUTING AND EQUIPMENT LOCATIONS WITH
PLUMBING AND ELECTRICAL INSTALLATIONS AND WITH BUILDING
STRUCTURAL MEMBERS.
E. THESE MECHANICAL DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE NOT TO
BE SCALED. BEFORE BEGINNING WORK, THE CONTRACTOR SHALL VISIT THE
SITE AND COMPLETE MEASURED SURVEY AND CREATE LAYOUT DRAWINGS AS
REQUIRED BY THE SPECIFICATIONS. WORK SHALL NOT BEGIN UNTIL ALL
LAYOUT DRAWINGS ARE APPROVED BY THE COR.
F. DUCT SIZES INDICATED ARE MINIMUM CLEAR INSIDE DIMENSIONS. WHERE
DUCT LINER OCCURS, INCREASE SHEET METAL DUCT SIZES TO
ACCOMMODATE LINER.
G. DUCT AND PIPE SUPPORTS ARE NOT SHOWN ON DRAWINGS.
H. SUPPORT ALL DUCTS, PIPING, AND EQUIPMENT FROM PRIMARY BUILDING
STRUCTURAL MEMBERS. PROVIDE ADDITIONAL STRUCTURAL MEMBERS
WHERE NECESSARY TO ACCOMPLISH THIS REQUIREMENT.
I. NEW AND EXISTING SUPPORT, RODS, AND ASSOCIATED APPURTENANCES
SHALL NOT RESTRICT EQUIPMENT SERVICE AND MAINTENANCE ACCESS.
EXISTING SUPPORTS SHALL BE MODIFIED TO PROVIDE FOR EQUIPMENT
SERVICE AND MAINTENANCE ACCESS.
J. DUCT SUPPORTS SHALL BE IN STRICT ACCORDANCE WITH SMACNA HVAC
DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE -SECOND EDITION
EXCEPT THAT HANGER WIRE SHALL NOT BE USED TO SUPPORT DUCTS OR
EQUIPMENT, AND HANGERS THAT REQUIRE PENETRATION OF DUCT WITH
BOLTS, RIVETS, SCREWS, WIRES OR ANY OTHER FASTENER SHALL NOT BE
USED. DO NOT DAMAGE THE EXISTING SLAB OR JOIST REINFORCING DURING
HANGER INSTALLATION. THE CONTRACTOR SHALL FIELD VERIFY EXISTING
REINFORCING THOUGH NON-DESTRUCTIVE MEANS AS REQUIRED TO INSTALL
NEW HANGERS.
K. CONTRACTOR SHALL REWORK EXISTING HANGERS AND OTHER SUPPORT FOR
DUCT AND PIPING TO COORDINATE WITH NEW EQUIPMENT AND WALL
LOCATIONS. ADD SUPPORT (TRAPEZE, CLEVIS, ETC) AT EQUIPMENT AND ON
EACH SIDE OF NEW WALLS SO FULL WEIGHT OF DUCT AND PIPING IS
SUPPORTED FROM STRUCTURE AND EQUIPMENT AND NEW WALLS BEAR NO
WEIGHT.
L. CONTRACTOR SHALL PROVIDE A LIST OF ALL MECHANICAL EQUIPMENT,
DEVICES, AND ALL APPURTENANCES REQUIRING POWER TO THE COR FOR
REVIEW AND APPROVAL AS PART OF COORDINATION FOR THIS PROJECT. LIST
ALL ELECTRICAL REQUIREMENT CHARACTERISTICS, INCLUDING BUT NOT
LIMITED TO VOLTAGE, AMPERAGE, PHASE, DISCONNECTING MEANS, OVER
CURRENT PROTECTION AND ALL CHARACTERISTICS FOR A FULLY
FUNCTIONAL AND COORDINATED SYSTEM. REFER TO ELECTRICAL DRAWINGS
FOR VOLTAGE REQUIREMENTS OF ALL EQUIPMENT.
M. DO NOT USE SCHEDULED EQUIPMENT IDENTIFICATION NUMBERS SHOWN ON
DRAWINGS FOR FINAL EQUIPMENT SIGNS AND FOR CONTROL SYSTEM
SCHEMATICS. CONTACT COR AND OBTAIN FROM REFRIGERATION AND HVAC
MAINTENANCE SUPERVISOR THE CORRECT NOMENCLATURE AND EQUIPMENT
NUMBERS FOR INCLUSION IN SIGNAGE, CONTROL SCHEMATICS, AND AS-BUILT
DRAWINGS.
N. CONTROL DEVICES ASSOCIATED WITH THE WORK OF THIS PROJECT SHALL BE
RELOCATED AS NECESSARY SO THAT THE FINAL PRODUCT RESULTS IN A
FULLY FUNCTIONAL AND FULLY ACCESSIBLE SYSTEM. CONTRACTOR SHALL
RELOCATE ALL EXISTING CONTROLS, SENSORS, PROBES, OR OTHER DEVICES
AND PROVIDE NEW WIRING, CONDUIT, AND/OR TUBING TO EXTEND SUCH
DEVICES AS NECESSARY TO PRODUCE A FULLY FUNCTIONAL SYSTEM EQUAL
OR BETTER THAN EXISTING. PROTECT AND STORE ALL SUCH RELOCATED
DEVICES.
O. CONTRACTOR SHALL PROVIDE PRIMING AND PAINTING OF ALL FERROUS
METALS AND PIPING ASSOCIATED WITH THIS PROJECT, INCLUDING ANY AND
ALL AREAS DAMAGED BY CONTRACTOR. FINISH COLORS SHALL MATCH
EXISTING WHERE ESTABLISHED. REFER TO SPECIFICATION 099100 PAINTING
FOR ADDITIONAL INFORMATION.
GENERAL MECHANICAL NOTES DEMOLITION MECHANICAL NOTES
A. EQUIPMENT INDICATED TO BE REMOVED SHALL BE REMOVED FROM THE
PROJECT SITE IN ITS ENTIRETY INCLUDING ALL HANGERS, ELECTRICAL
CONDUIT, WIRING, JUNCTION BOXES, PIPING, CONTROLS, ACCESSORIES AND
ALL APPURTENANCES THAT ARE RENDERED USELESS OR ABANDONED BY
THE REMOVAL OF THE INDICATED EQUIPMENT.
B. WHERE THESE DOCUMENTS REQUIRE REMOVAL OF DUCTWORK, PIPING,
EQUIPMENT OR ASSOCIATED APPURTENANCES, CONTRACTOR SHALL
PROTECT ALL EXISTING-TO-REMAIN COMPONENTS FROM DAMAGE.
CONTRACTOR SHALL COVER ALL OPENINGS IN DUCT, PIPING, EQUIPMENT,
AND ANY OTHER DEVICE FROM CONSTRUCTION DUST AND DEBRIS.
C. WHERE EQUIPMENT, DUCTWORK, OR PIPING IS TO BE REMOVED THAT IS IN-
SERVICE, CONTRACTOR SHALL GIVE NOTICE TO THE COR OF ANY
INTERRUPTIONS ANTICIPATED. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO COORDINATE ALL SHUTDOWNS OR INTERRUPTIONS TO THE
SATISFACTION OF THE COR AND HOSPITAL STAFF.
A. CONTRACTOR SHALL PHASE ALL WORK AS REQUIRED TO MAINTAIN
CONTINUOUS OPERATION OF THE HOSPITAL.
B. HOSPITAL OPERATIONS SHALL NOT BE INTERRUPTED DUE TO THE WORK OF
THIS PROJECT EXCEPT FOR SCHEDULED SHUTDOWNS OF NO LONGER THAN
ONE HOUR. CONTRACTOR SHALL GIVE REASONABLE NOTICE TO COR
BEFORE ANY SUCH SHUTDOWN OR INTERRUPTION.
C. WHERE LONGER SHUTDOWNS ARE REQUIRED TO COMPLETE THE WORK
DESCRIBED IN THIS DOCUMENT, THE CONTRACTOR SHALL SCHEDULE THE
EVENT A MINIMUM OF 3 WEEKS PRIOR TO COMMENCING WORK. ALL SUCH
SHUTDOWNS AND INTERRUPTIONS SHALL BE MINIMIZED AND SHALL UTILIZE
WEEKENDS, FEDERAL HOLIDAYS, NIGHTS, AND OTHER TIMES WHEN HOSPITAL
OPERATIONS ARE MINIMIZED AND OTHER SUCH TIMES AGREEABLE TO THE
COR.
D. WHERE NECESSARY TO INTERRUPT CONTINUOUS OPERATION OF THE
HOSPITAL, THE CONTRACTOR SHALL DIVIDE WORK INTO PHASED
CONSTRUCTION THAT IS NOT NECESSARILY SHOWN ON THESE DOCUMENTS.
AS PART OF SCHEDULING AN INTERRUPTION OR SHUTDOWN, THE
CONTRACTOR SHALL PROVIDE THE COR WITH A DETAILED SHUTDOWN PLAN
INDICATING THE SYSTEMS AFFECTED, INCLUDING BUT NOT LIMITED TO
ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION,
AND OTHER SYSTEMS INVOLVED. THE PLAN SHALL INCLUDE THE WORK TO
BE PERFORMED, THE LENGTH OF INTERRUPTION, AND A DETAILED PHASING
AND MANNING DESCRIPTION. THE PLAN SHALL INCLUDE AND ADDRESS
CONTINGENCY FOR MITIGATING ANY DELAYS THAT MAY OCCUR IN THE
PLANNED WORK. PROVIDE THIS PLAN TO THE COR 5 WEEKS BEFORE THE
EVENT FOR APPROVAL.
E. CONTRACTOR SHALL WORK ABOVE THE CEILING TO ADD COMPONENTS,
SUCH AS PIPING, INSULATION, CONDUCTORS, CONDUITS, AND SUPPORTS.
THE CONTRACOR SHALL COORDINATE INSTALLATION WITH THE COR. THE
CONTRACTOR SHALL REMOVE, STORE, AND REINSTALL ALL CEILING AND
OTHER COMPONENTS ASSOCIATED WITH INSTALLATION. WHERE ITEMS TO BE
REINSTALLED ARE DAMAGED (ACCORDING TO THE COR) THE CONTRACTOR
SHALL REPLACE THE ITEM WITH NEW.
PHASING MECHANICAL NOTES
A. THE TEST AND BALANCE CONTRACTOR SHALL BE A SUBCONTRACTOR TO THE
PRIME CONTRACTOR AND NOT A SUBCONTRACTOR TO THE MECHANICAL OR
ANY OTHER SUBCONTRACTOR.
B. PRIOR STARTING WORK, THE CONTRACTOR SHALL PROVIDE A TEST REPORT
OF EXISTING SYSTEMS THAT IN THIS SCOPE OF WORK.
TEST AND BALANCE MECHANICAL NOTES
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER
DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS
SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.
A. DATA LINK COMMUNICATION IS ETHERNET (ISO 8802-3) AND BACNET/IP.
B. GROUND CABLE SHIELDS, DRAIN CONDUCTORS, AND EQUIPMENT TO
ELIMINATE SHOCK HAZARD AND TO MINIMIZE GROUND LOOPS, COMMON-
MODE RETURNS, NOISE PICKUP, CROSS TALK, AND OTHER IMPAIRMENTS.
C. CABLE CONDUCTORS SHALL PROVIDE PROTECTION AGAINST INDUCTION IN
CIRCUITS. CROSSTALK ATTENUATION WITHIN THE SYSTEM SHALL BE IN
EXCESS OF -80 DB THROUGHOUT ALL FREQUENCY RANGES USED.
D. CABLE RUNS: KEEP CABLE RUNS AS SHORT AS POSSIBLE. ALLOW EXTRA
LENGTH FOR CONNECTING TO THE TERMINAL BOARD. DO NOT BEND FLEXIBLE
COAXIAL CABLES IN A RADIUS LESS THAN TEN TIMES THE CABLE OUTSIDE
DIAMETER.
E. LABEL SYSTEM’S CABLES ON EACH END. TEST AND CERTIFY CABLES IN
WRITING TO THE VA BEFORE CONDUCTING PROOF-OF-PERFORMANCE
TESTING. MINIMUM CABLE TEST REQUIREMENTS ARE FOR IMPEDANCE
COMPLIANCE, INDUCTANCE, CAPACITANCE, SIGNAL LEVEL COMPLIANCE,
OPENS, SHORTS, CROSS TALK, NOISE, AND DISTORTION, AND SPLIT PAIRS ON
ALL CABLES IN THE FREQUENCY RANGES USED. MAKE AVAILABLE ALL CABLE
INSTALLATION AND TEST RECORDS AT THE DEMONSTRATION TO THE VA.
F. POWER WIRING SHALL NOT BE RUN IN CONDUIT WITH COMMUNICATIONS
TRUNK WIRING OR SIGNAL OR CONTROL WIRING OPERATING AT 100 VOLTS
OR LESS.
G. PROVIDE NEMA 4 ENCLOSURE FOR EXTERIOR LOCATIONS.
H. PROVIDE BACNET-COMPLIANT ROUTER, BRIDGE, SWITCH, HUB, MODEM,
GATEWAY, INTERFACE, AND SIMILAR COMMUNICATION EQUIPMENT TO
INTEGRATE INTO THE EXISTING SYSTEM.
I. FIT ALL EQUIPMENT CONTAINED IN CABINETS OR PANELS WITH SERVICE
LOOPS, EACH LOOP BEING AT LEAST 300 MM (12 INCHES) LONG. EQUIPMENT
FOR FIBER OPTICS SYSTEM SHALL BE RACK MOUNTED, AS APPLICABLE, IN
VENTILATED, SELF-SUPPORTING, CODE GAUGE STEEL ENCLOSURE. CABLES
SHALL BE SUPPORTED FOR MINIMUM SAG.
J. OPTICAL DIGITAL COMMUNICATION FIBER, IF USED, SHALL BE MULTIMODE OR
SINGLE MODE FIBER, 50/125 MICRON FOR MULTIMODE OR 10/125 MICRON FOR
SINGLE MODE MICRON WITH SC OR ST CONNECTORS AS SPECIFIED IN
TIA-568-C.1. TERMINATIONS, PATCH PANELS, AND OTHER HARDWARE SHALL
BE COMPATIBLE WITH THE SPECIFIED FIBER. FIBER-OPTIC CABLE SHALL BE
SUITABLE FOR USE WITH THE 100BASE-FX OR THE 100BASE-SX STANDARD (AS
APPLICABLE) AS DEFINED IN IEEE STD 802.3.
GENERAL CONTROL ELEMENT REQUIREMENT
A. THE MONITORING SYSTEM SHALL BE MANUFACTURED BY
MEDICALRESOURCES MODEL CHECKPOINT G2 SYSTEM, IT SHALL BE
WIRELESS, OPERATE IN THE 900 MHZ ISM FREQUENCY RANGE, AND COMPLY
WITH FCC REGULATIONS. IT SHALL UTILIZE A SELF-HEALING MESH NETWORK
FOR RELIABLE 2-WAY COMMUNICATION AMONG SENSORS, REPEATERS,
RECEIVERS, AND ETHERBASES. THE SYSTEM SHALL BE BATTERY-POWERED,
WATER-RESISTANT SENSORS AND SHALL CONTINUOUSLY TRANSMIT DATA AT
PROGRAMMED INTERVALS. IT SHALL HAVE A DEDICATED VISUAL BASICS
SOFTWARE RUNNING ON A PC WITH MODEST HARDWARE REQUIREMENTS.
BASE STATION TRANSMITTER SPECIFICATION
P R
O
FESS I ONA L ENG
I N E
E R
JE
REM
Y M. KNOWLESL I C E NS E
F L O R I D A
NEURO. SCI
1A-170
NEURO. SCI
1A-172
CAST
1A-174
MED.
SUP./MEDIC.
1A-168
EXAM
1A-150
NEURO
1A-171
NEURO
1A-169
EXAM
1A-152
EXAM
1A-154
HAC
1A-166
STAFF TLT
1A-167
PROC.
1A-149
EXAM
1A-151
EXAM
1A-153
MED. SUP. /
MEDIC.
1A-144
EXAM
1A-146
STORAGE
1A-148
C&P EXAM
1A-129
C & P EXAM
1A-147
C & P EXAM
1A-145
C&P EXAM
1A-131
C&P EXAM
1A-133
HAC
1A-142
STAFF TLT
1A-143
EXAM
1A-132
EXAM
1A-130
TLT
1A-106
MED. EQ.
1A-108
SOCIAL
1A-102
CLEAN
1A-103
SOIL
1A-105
OBS.
1A-107
OBS.
1A-109
OBS.
1A-111
OBS.
1A-112
BASIC
SERVICE
1A-104
PHARMD
1A-134
TRIAGE
1A-136
TLT
1A-100
TLT
1A-101
C&P CLERK
1A-135
NURSES
STATION
1A-140
CHECK-IN/OUT
1A-137
ELEC.
1A-158
CLEAN
1A-156
SOIL
1A-157
PHARMD
1A-159
PHARMD
1A-160
CASE
1A-164
STORAGE
1A-165
TLT
1A-161
TLT
1A-162
HAS
SUPER.
1A-179
CHECK-IN/OUT
1A-180
SERVICE
OFFICE
1A-192
SERVICE
OFFICE
1A-194
SERVICE
OFFICE
1A-196
SERVICE
OFFICE
1A-19…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .