Att. 7 Addendum to Drawings-36C77623B0054.pdf
PDF 7 MB Posted
- Solicitation number
- 36C77623B0054
About this file
This document package includes construction drawings and specifications for improving site waste management at the Iowa City VA Medical Center. The project involves renovating existing basement spaces to consolidate waste handling functions, including hazardous storage, a pump room, laundry, compactors, and medical gas manifolds. Work includes demolishing walls and flooring, installing new resilient and resinous flooring, wall protection panels, mechanical systems, and modifying the building envelope. Drawings show demolition plans, new partitions, finishes, equipment, and details. Mechanical drawings cover HVAC, plumbing, and exhaust systems. Specifications address requirements for general construction, hazardous abatement, and specialized construction and finishes. The solicitation is for a fixed-price construction contract to be awarded by the VA Technology Acquisition Center in Austin, with a period of performance through final completion.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MED GAS MANIFOLDS
BS10B
622 SF
EMS EQUIPMENT
STORAGE
BS05B
SOILED LINEN
BS07
STORAGE
BS10
HAZARDOUS
STORAGE (RMW)
BS03
PUMP ROOM
BS05A
POWER WASH
BS05
COMPACTOR ROOM
BS10A
CORRIDOR
BCS03
CORRIDOR
BCS05
CORRIDOR
BCS03A
IT CLOSET
A. PROVIDE AN INFECTION CONTROL RISK ASSESSMENT BARRIER AROUND THE
PROJECT AREA AS APPROVED BY THE VHA COR. REFER TO SPECIFICATION
SECTION NO. 013526, SAFETY REQUIREMENTS.
B. ENSURE THAT EXISTING CONDITIONS WHICH ARE NOT IN CONTRACT REMAIN
UNDAMAGED THROUGHOUT THE DURATION OF CONSTRUCTION. ANY
DAMAGED EXISTING CONDITIONS MUST BE REPLACED IN-KIND.
C. REFER TO FIRE PROTECTION, MECHANICAL, ELECTRICAL , TELECOM, AND
PLUMBING SPECIFICATIONS AND DRAWINGS FOR OTHER DEMOLITION
INFORMATION & REQUIREMENTS.
D. OCCUPIED AREAS CANNOT HAVE MORE THAN 3 CEILING TILES OUT AT A TIME
(PUT TILE BACK AT NIGHT HOURS). REFER TO THE VAMC STANDARD
OPERATING PROCEDURES (SOP).
E. REMOVE, REFURBISH/CLEAN, PROTECT AND STORE FIXTURES TO BE
REINSTALLED.
F. VERIFY AND COORDINATE ANY ACCESS TO AND SCHEDULE OF ANY
REQUIRED UTILITY SHUT-OFFS TO ACCOMPLISH SCOPE OF WORK WITH VHA
COR FOURTEEN (14) DAYS PRIOR TO THE WORK BEING DONE
G. DO NOT REMOVE OR OTHERWISE MODIFY ANY BUILDING STRUCTURAL
COMPONENTS UNLESS APPROVED BY THE VHA COR.
H. WHERE EXISTING INTERIOR WALLS ARE REMOVED, INFILL DEPRESSIONS IN
FLOOR SLABS WITH CONCRETE TO BE FLUSH WITH ADJACENT FLOOR LEVEL.
I. REMOVE EXISTING FLOOR COVERINGS EXCEPT EXISTING TERRAZZO.
J. AFTER CEILINGS HAVE BEEN DEMOLISHED, CLEAN ALL PLUMBING,
MECHANICAL, AND ELECTRICAL ITEMS OF DUST AND DEBRIS. REPAIR AND
PATCH CONCRETE CEILINGS TO BE EXPOSED FOR FUTURE STAIN OR PAINT
FINISH.
9 10 11 11.1 11.2 11.7
A
B
C1
C
D
E
E.1
STAIR
BST05
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
IT CLOSET
IT CLOSET
9 9
9 9
11 11
22 22
25 26
25 26
ITEMS TO BE DEMOLISHED DEMOLITION SCOPE
DEMOLITION LEGEND
EXISTING TO REMAIN
DEMOLITION FLOOR FINISH
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
AD110
ARCHITECTURAL DEMOLITION
PLAN BASEMENT LEVEL
IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
1. REMOVE VCT AND WALL BASE.
2. TERRAZZO FLOORING TO REMAIN.
3. TERRAZZO TO REMAIN; RESINOUS FLOOR COVERING ON TOP OF IT HAS
TESTED POSITIVE FOR LEAD AND WILL BE ABATED.
4. DEMOLISH FLOORING AND WALL BASE.
5. REMOVE EXISTING MANHOLE COVER AND ASSOCIATED EMBEDDED TRIM
RING IN FLOOR SLAB ; VERIFY VAULT UNDERNEATH IS COMPLETELY
ABANDONED AND FILL VAULT WITH CONCRETE.
6. EXISTING COMPACTOR SHUTOFF SWITCH TO REMAIN.
7. REMOVE DOOR AND FRAME.
8. REMOVE LOUVER, EXHAUST VENT, WINDOW, AND CAST STONE WINDOW
SILL.
9. REMOVE WALL.
10. REMOVE WALL FOR NEW DOOR OPENING.
11. REMOVE WALL FURRING.
12. SALVAGE SIGNAGE. REINSTALL AT SAME LOCATION.
13. EXISTING HOUSEKEEPING PAD TO REMAIN.
14. EXISTING GREASE INTERCEPTOR TO REMAIN.
15. EMERGENCY SHOWER TO BE RELOCATED.
16. REMOVE ACCESS DOOR FOR TRASH COMPACTOR (EQUIPMENT ITEM TIED
TO COMPACTOR).
17. REMOVE GUARD.
18. REMOVE FLOOR TILE TO EXTENT OF NEW CORRIDOR WALL LOCATION.
19. REMOVE FULL HEIGHT OF METAL PANEL WHERE EXISTING DRYER DUCT IS
REMOVED AND NEW DRYER DUCT IS INSTALLED. VERIFY PANEL WIDTH IN
FIELD.
20. REMOVE NON-RATED DAMAGED ACCESS PANEL IN 2 HOUR RATED WALL.
21. REMOVE TRENCH DRAIN, COORDINATE WITH PLUMBING
22. REMOVE FLOOR SLAB FOR NEW TRENCH DRAIN AND ASSOCIATED PIPING,
COORDINATE WITH PLUMBING
23. EXISTING WALL CONSTRUCTION IS RED BRICK MASONRY.
24. EXISTING WALL CONSTRUCTION IS STANDARD CMU MASONRY.
25. EXISTING WALL CONSTRUCTION IS CLAY TILE BRICK MASONRY.
26. EXISTING WALL CONSTRUCTION IS GLAZED CMU MASONRY.
24'12'6'3'1'-6"0'
P la n N or th
T ru e N or th
3/16" = 1'-0"
BASEMENT LEVEL DEMOLITION PLAN
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
A-210 1
9 10 11 11.1 11.2 11.7
A
B
C1
C
D
E
E.1
STAIR
BST05
BS03
HAZARDOUS
STORAGE
PUMP ROOM
BS05A
BS05
POWER
WASH
ASH SILO
BSO5C
BS07
COMPACTOR
ROOM
BS10
MED GAS
MANIFOLDS
CORRIDOR
BCS05
BS07B
LAUNDRY
BUILDING 36
MED GAS
STOR
BS07A
GREASE
INTERCEPTOR
BS08
SOILED
LINEN
A-412 8
A-4139
A-412
A-4129
A-412
2 4
A-4119
A-310
A-310
A-310
BS05.1
BS03
B S
A5'
BS07
CORRIDOR
BCS03
BUILDING 19
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
M6A
M6A
F2A.A
F2A.A
F2A.A
F2A.A
IT CLOSET
6' - 8"
A-411
A-411
A-411
M6A
M6A
A-410
B S
BS08
BS09
ELEC
BS09
M6A
M8A
M8A
M6A
M6A
A-510
A-510
A-510
A-510
A-510
BS07C
EQMT
STORAGE
A-320
A-320
A-320
A-321
6'
8'
M8A
M8A
A-320
2' - 8"
2'
/4
3/
4"
6' - 8" 4' - 8"
1'
/4
7'
FEC
FEC
FEC
M8A.1
M8A.1
60' - 1"
9'
1"
B S
.2
SIM
SIM
12 13
A-540
/4
FEC
A. REFER TO FIRE PROTECTION, MECHANICAL, PLUMBING, AND ELECTRICAL
SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION AND
COORDINATION.
B. REFER TO SHEETS GI002 AND GI003 FOR ADDITIONAL INFORMATION.
C. FIRE-RESISTANCE RATED PARTITIONS TO EXTEND TO UNDERSIDE OF ONE
WAY BEAM AND SLAB CONCRETE STRUCTURE WITH JOINT SEALANTS AT TOP
OF PARTITION. REFER TO SPECIFICATION SECTION 061000 AND
SPECIFICATION SECTION 079200.
D. PAINT ALL EXPOSED CMU WALLS ABOVE FRP WALL PROTECTION PANELS
PNT-2.
E. SEAL ALL INTERIOR AND EXTERIOR WALL PENETRATIONS.
F. INFILL FLOOR WITH CONCRETE FLUSH TO ADJACENT FLOOR LEVEL WHERE
EXISTING WALLS WERE REMOVED.
G. EXISTING WALL FINISH IN POWER WASH ROOM BS05 IS CERAMIC GLAZED
FACING BRICK (CGFB-1); ASTRA-GLAZE-SW+ RECYCLED GLAZED CONCRETE
MASONRY UNITS; TRENWYTH 'SAND'; 7-3/4" X 15-3/4" SIZE. COMPANY CAN
MAKE CUSTOM COLORS IF THIS COLOR IS NO LONGER AVAILABLE AS A
STANDARD COLOR.
H. EXISTING METAL PANELS ON BUILDING 36 ARE SIMILAR TO FABRAL ULTRA
RIB EXPOSED FASTENER ROOFING AND SIDING PANEL; DARK BRONZE (BASIS
OF DESIGN). VERIFY IN FIELD.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
8:
A M
A-110
ARCHITECTURAL PLAN BASEMENT
LEVEL
IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
24'12'6'3'1'-6"0'
P la n N or th
T ru e N or th
3/16" = 1'-0"
BASEMENT LEVEL ARCHITECTURAL PLAN
1. ALIGN FACES OF NEW AND EXISTING MASONRY PARTITIONS.
2. ALIGN FACES OF NEW AND EXISTING GYPSUM BOARD PARTITIONS.
3. PATCH HOLE IN WALL FOR PREVIOUS DRAIN LINE. CERAMIC GLAZED FACED
BRICK CMU SURFACE TO MATCH ADJACENT WALL COLOR AND TEXTURE.
MATCH EXISTING GROUT COLOR.
4. NEW 6"X6" CONCRETE CURB WITH 42" AFF GUARD ATOP.
5. INFILL ABANDONED CONCRETE VAULT AND FLOOR SLAB VOID WITH
CONCRETE WHERE MANHOLE COVER AND TRIM RING WHERE REMOVED
AND FINISH TO MATCH ADJACENT FLOOR SURFACE. VERIFY LOCATION AND
SIZE IN FIELD.
6. LOCATION OF TRASH COMPACTOR/STORAGE UNIT.
7. EXISTING WALL FINISHES TO REMAIN. POWERWASH GLAZED MASONRY AND
GROUT SURFACES; REMOVE RUST STAINS; REPAIR ANY DAMAGE; SEAL
TILE/GLAZED MASONRY AND GROUT.
8. NEW OSHA COMPLIANT COMPACTOR DOORS (EQUIPMENT ITEM INTEGRAL
TO TRASH COMPACTOR).
9. NEW FULL HEIGHT METAL PANEL TO MATCH EXISTING ADJACENT AT
LOCATION OF REMOVED AND NEW (SEE MECH DWGS) DRYER VENT DUCT IN
BUILDING 36. VERIFY SIZES IN FIELD.
10. REINSTALLED EMERGENCY SHOWER/EYEWASH.
11. NEW FIRE RATED ACCESS PANEL (1.5 HOUR)TO REPLACE EXISTING
NON-COMPLIANT/DAMAGED ONE.
12. CONFINED SPACE TO ACCESS FIRE PROTECTION VALVE.
13. EXISTING FIRE PROTECTION VALVE ABOVE CEILING TO BE RELOCATED TO
STAIRWELL. SEE FIRE PROTECTION DRAWINGS.
14. NEW 42" AFF GUARD.
15. INFILL FLOOR SLAB TO MATCH EXISTING
16. NEW TRENCH DRAIN, REFER TO PLUMBING
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
A
B
C1
C
D
E
E.1
STAIR
BST05
BS03
HAZARDOUS
STORAGE
BS05A
PUMP
ROOM
BS05
POWER
WASH
ASH SILO
BSO5C
BS07
COMPACTOR
ROOM
BS10
MED GAS
MANIFOLDS
CORRIDOR
BCS05
BS07B
LAUNDRY
BUILDING 36
MED GAS
STOR
BS07A
GREASE
INTERCEPTOR
BS08
SOILED
LINEN
CORRIDOR
BCS03
BUILDING 19
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
IT CLOSET
CG-02CG-02
CG-02
CG-02
CG-02CG-02
CG-02
CG-02CG-02
CG-02
CG-01
CG-02
CG-02
CG-02
CG-02CG-02
CG-02
CG-02CG-02
CG-02
BS07C
EQMT
STORAGE
CG-02 CG-02
CG-02
CG-02
CG-02 CG-02
CG-01CG-01
HR-1HR-1
EG-1EG-1
A-550
CG-01CG-01
CG-01CG-01
4" 5' - 2"
3'
3'
DASH-DOT
LINETYPE IS FRP
PANEL, TYP. SEE
INTERIOR
ELEVATIONS.CG-02
CG-02
THIS SYMBOL IS FOR HANDRAILS
(HERE TO ALLOW ELECTRICAL
CORD ACCESS TIGHT TO WALL).
TYPICAL: REFER TO ELEVATIONS
FOR LOCATIONS AND MOUNTING
HEIGHTS OF WALL PROTECTION.
CG-01CG-01
A. ALL OUTSIDE CORNERS WITHIN EMS AND MEDICAL GAS AREAS ARE TO HAVE
CG-02, AND ALL OUTSIDE CORNERS AT NEW AND EXISTING PARTITIONS IN
CORRIDOR TO HAVE CG-01.
B. NEW CORRIDOR WALLS OUTSIDE SITE WASTE MANAGEMENT TO MATCH
EXISTING ADJACENT FINISHES INCLUDING PAINT FINISH, WALL BASE, AND
WALL PROTECTION CRASH/BUMPER RAILS.
C. GYPSUM BOARD CEILINGS AND SOFFITS ARE TO BE GLASS MAT FACED
GYPSUM BOARD. REFER TO SPECIFICATION SECTION 092900.
D. ALL METAL PAINTED SURFACES SHALL BE SHOP OR MANUFACTURER
FINISHED WITH PVDF ('KYNAR') COATING.
E. PARTITIONS WITHIN EMS ARE MEDICAL GAS AREAS, WITH THE EXCEPTION OF
THE POWER WASH ROOM, ARE TO BE CLAD WITH 10'-0" TALL OR FULL HEIGHT
(WHERE CEILINGS ARE BELOW 10'-0" AFF) FRP WALL PROTECTION PANELS.
REFER TO INTERIOR ELEVATIONS. CMU SUBSTRATE BEHIND FRP TO BE
SMOOTHED WITH FILLER. FRP PANELS TO HAVE MATCHING PLASTIC DIVIDER
STRIPS AND END CAPS.
F. CRASH AND HAND RAILS AS INDICATED ON PLAN AND INTERIOR ELEVATIONS.
G. FLOORING TYPE TRANSITIONS AT DOORS ARE TO BE TO THE CENTERLINE OF
DOOR.
H. REPLACE ANY DAMAGED FLOORING IN EXISTING CORRIDORS TO MATCH
EXISTING ADJACENT.
I. RESINOUS FLOORING TO BE CONTINUOUS OVER AND ON CONCRETE CURBS
AND HOUSEKEEPING PADS (RES-1 AND RESB-1).
EXISTING RESILIENT
TILE FLOORING
SC-1 SEALED CONCRETE
RES-1 RESINOUS FLOORING
FINISH FLOOR LEGEND
VCT-1 NEW RESILIENT TILE
FLOORING TO MATCH EXISTING
EXISTING RESILIENT SHEET
FLOORING
LVT-1 NEW RESILIENT SHEET
FLOORING TO MATCH EXISTING
INTERIOR FINISH LEGEND
FLOORING
LVT-1 TO MATCH EXISTING ADJACENT: LUXURY VINYL TILE; TANDUS
CENTIVA EVENT SERIES CLASSIC STONE OKARA GRAY ECL 7126
RES-1 RESINOUS FLOORING; DUR-A-FLEX POLY-CRETE MDQ Q28-23,
ARMOR TOP GLOSS
RES-2 RESINOUS FLOORING; DUR-A-FLEX POLY-CRETE MDQ Q28-17,
ARMOR TOP GLOSS (FOR YELLOW BORDER AT EMERG. SHOWER)
SC-1 SEALED CONCRETE
VCT-1 TO MATCH EXISTING ADJACENT: VINYL FLOOR TILE; ARMSTRONG
STANDARD EXCELON IMPERIAL TEXTURE COTTAGE TAN 51830
BASE
RB-1 RESILIENT BASE; TO MATCH EXISTING ADJACENT (ROPPE P193
BLACK BROWN, VIF); 4" TALL
RB-2 RESILIENT BASE; ROPPE P193 BLACK BROWN, VIF); 6" TALL
RESB-1 BUILT-UP RESINOUS FLOORING; 6" TALL ; DUR-A-FLEX POLY-CRETE
MDQ Q28-23, ARMOR TOP GLOSS ; ZINC CAP STRIP
CEILING
AT ARMSTRONG - WHITE / TEGULAR - CIRRUS #584
PNT-1 SHERWIN WILLIAMS - SW7036 ACCESSIBLE BEIGE
PNT-2 SHERWIN WILLIAMS - SW6105 DIVINE WHITE
WALLS
CGFB-1 ASTRA-GLAZE-SW+ RECYCLED GLAZED CMU; TRENWYTH 'SAND'
PNT-1 SHERWIN WILLIAMS - SW7036 ACCESSIBLE BEIGE
PNT-2 SHERWIN WILLIAMS - SW6105 DIVINE WHITE
WALL PROTECTION
CG-01 CORNER GUARD, RESIN, FULL HEIGHT. TO MATCH EXISTING
CG-02 CORNER GUARD, FULL HEIGHT. STAINLESS STEEL, 304, #4 FINISH
EG-1 END GUARD, FULL HEIGHT. STAINLESS STEEL, 304, #4 FINISH
CR-1 CRASH RAIL, RESIN. INPRO - NUTREE BLACK; 8" TALL
HR-1 HAND RAIL, RESIN. INPRO - BLACK, 5 1/2" TALL
FRP-1 FIBERGLASS WALL PROTECTION, CLASS A, .090" THICK, FULL
HEIGHT, MARLITE FRP P-145 SILVER
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-130
ARCHITECTURAL FINISH PLAN
BASEMENT LEVEL
IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
24'12'6'3'1'-6"0'
P la n N or th
T ru e N or th
3/16" = 1'-0"
BASEMENT LEVEL INTERIOR FINISHES PLAN
1. 4" WIDE YELLOW BORDER INTEGRAL PART OF RESINOUS FLOORING
SYSTEM.
2. NEW RESILIENT FLOORING TO MATCH EXISTING ADJACENT.
3. GUARD TO BE STEEL WITH PVDF ('KYNAR') FINISH.
4. NEW ACCESS DOORS FOR COMPACTOR TO BE STEEL WITH PVDF ('KYNAR')
FINISH.
5. EXISTING EXPANSION JOINT. PROTECT.
6. TOUCH UP ANY DAMAGED FINISHES IN STAIR WELL AFTER FIRE
PROTECTION VALVE IS RELOCATED..
7. NEW ACCESS PANEL PAINT COLOR TO MATCH ADJACENT WALL.
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
B
C1
C
D
E
E.1
STAIR
BST05
HAZARDOUS
STORAGE
BS03
PUMP ROOM
BS05A
POWER WASH
BS05
ASH SILO
BSO5C
COMPACTOR ROOM
BS07
MED GAS MANIFOLDS
BS10
CORRIDOR
BCS05
LAUNDRY
BS07B
BUILDING 36
MED GAS STOR
GREASE
INTERCEPTOR
BS07A
SOILED LINEN
BS08
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
IT CLOSET
CORRIDOR
BCS03
BS07C
EQMT
STORAGE
ELEC
BS09
M2028
M2071
M2205
M2400 M2300
M2100
K3421 K3422K3422
M2015
M2026
M2027 M2027M2025 M2117
M2081
F0510
M2015
M2200
M2650
M2652
M2016
F2020
A5135
FEC
FEC
FEC
M2081
FEC
K9300
K2021
K2022K2022
A5082
A5077
A5082
A5077 A5082
A5070 A5077
A5077
A5077
A5077
A5077
A5077
IN0404
IN0404
IN0404
IN0404
IN0404
IN0404
IN0404
IN0404
7 7
IN0404
IN0404
IN0404
IN0131
IN0131
CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
EQUIPMENT LEGEND
GOVERNMENT FURNISHED/
CONTRACTOR INSTALLED
GOVERNMENT FURNISHED/
CONTRACTOR ROUGH-IN
GOVERNMENT FURNISHED/
GOVERNMENT INSTALLED
EQUIPMENT ITEMS
GRAPHIC REPRESENTATION
CF/CI =
GF/CI =
GF/CR =
GF/GI =
A. INFORMATION SHOWN IS DIAGRAMMATIC AS NOT ALL EQUIPMENT
SPECIFICATIONS ARE KNOWN.
B. REFER TO ELECTRICAL, PLUMBING, AND MECHANICAL DRAWINGS AND
SPECIFICATIONS FOR UTILITY CONNECTIONS FOR EQUIPMENT.
C. REFER TO EQUIPMENT SCHEDULE FOR INDIVIDUAL EQUIPMENT ITEMS AND
REQUIREMENTS.
D. EQUIPMENT ITEMS THAT ARE GFGI ARE INSTALLED FOR COORDINATION
INFORMATION ONLY.
E. MEDICAL GAS MANIFOLDS SHALL BE INSTALLED BY INDIVIDUALS QUALIFIED
AND CERTIFIED PER NFPA 99 AND ASSE 6000 SERIES.
F. MEDICAL GAS MANIFOLDS SHALL BE INSPECTED, TESTED, AND CERTIFIED BY
A QUALIFIED PARTY OTHER THAN THE MEDICAL GAS INSTALLER.
QUALIFICATIONS ARE PER NFPA 99 AND ASSE 6000 SERIES.
G. ROOM IDENTIFICATION SIGNS TO BE 5'-0" TO TOP OF SIGN AND 2" FROM
EDGE OF DOOR FRAME PER VA STANDARDS. FIRE DOOR, WARNING, OR
OTHER GRAPHIC SIGNS ON DOORS TO BE SAME HEIGHT BUT CENTERED IN
DOOR WIDTH. SIGNS ABOVE FIRE EXTINGUISHERS TO BE 6'-8" TO BOTTOM OF
SIGN AND CENTERED OVER FIRE EXTINGUISHER CABINET.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-140
ARCHITECTURAL EQUIPMENT PLAN
& SCHEDULE BASEMENT LEVEL
IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
24'12'6'3'1'-6"0'
P la n N or th
T ru e N or th
3/16" = 1'-0"
BASEMENT LEVEL EQUIPMENT PLAN
1. EXISTING COMPACTOR SHUT OFF SWITCH TO REMAIN IN THIS LOCATION.
2. RELOCATED EMERGENCY SHOWER/EYEWASH
3. EXISTING MEDICAL GAS MANIFOLDS REINSTALLED IN RENOVATED ROOM
(BY CONTRACTOR). FOR CARBON DIOXIDE AND NITROGEN.
4. EXISTING GREASE INTERCEPTOR TO REMAIN IN OPERATION DURING
CONSTRUCTION.
5. EMPTY MEDICAL GAS CYLINDERS.
6. NEW MEDICAL GAS MANIFOLD REINSTALLED IN RENOVATED ROOM (CF/CI).
FOR NITROUS OXIDE.
7. WARNING SIGNS FOR MEDICAL GAS CONTAINING ROOMS (IN-01.16.02
SERIES PER VA TIL PG-18-10) AS DIRECTED BY VA COR AND VA INTERIOR
DESIGNER.
8. REINSTALL SALVAGED EXISTING SIGNAGE AT SAME LOCATION.
EQUIPMENT SCHEDULE
JSN DESCRIPTION WIDTH DEPTH HEIGHT
NEW /
EXISTING SOURCE MOUNTING PLUG-IN
GFCI
OUTLET
WATER
CONNECTION DRAIN
A5070 HAND SOAP DISPENSER 0'-6" 0'-3" 0'-10" NEW GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A N/A N/A
A5077 HAND SANITIZER DISPENSER 0'-5" 0'-4" 0'-10" NEW GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A N/A N/A
A5082 PAPER TOWEL DISPENSERR 1'-0" 0'-7" 1'-0" NEW GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A N/A N/A
A5135 MOP HOLDER, RAG HOOKS, STAINLESS STEEL 2'-10" 0'-8" 1'-1" NEW CF/CI WALL-MOUNTED N/A N/A N/A N/A
F0510 SOILED LINEN TRANSPORT CARTS 6'-0" 2'-2" 6'-0" EXISTING GF/GI N/A N/A N/A N/A N/A
F2020 44 GALLON ROUNDS BINS FOR HAZARDOUS (RED BAG)
WASTE
2'-1" 2'-1" 2'-9" EXISTING GF/GI N/A N/A N/A N/A N/A
IN0131 SIGN, PERPENDICULAR TO WALL, FIRE EXTINGUISHER 0'-6" 0'-2" 0'-8" NEW GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A N/A N/A
IN0404 SIGN, ROOM IDENTIFICATION 0"-7" 0"-1/4" 0-8" NEW GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A N/A N/A
K2021 WASHING MACHINE DETERGENT DISPENSER PUMP 2'-0" 1'-0" 1'-0" EXISTING GF/CI
(INSTALL)
WALL-MOUNTED PLUG-IN GFCI (ELEC) WATER DRAIN
K2022 CHEMICAL PUMPS AND STORAGE; FOR DRAIN CLEAN
OUT
0'-5" 0'-3" 0'-6" EXISTING GF/GI WALL-MOUNTED PLUG-IN GFCI (ELEC) N/A DRAIN
K3421 WALL MOUNTED HOSE REEL, PERPENDICULAR TO WALL
UNIT
0'-9" 1'-6" 1'-6" EXISTING GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A WATER DRAIN
K3422 WALL MOUNTED HOSE REEL, PARALLEL TO WALL UNIT 0'-10" 2'-0" 2'-0" EXISTING CG/CI WALL-MOUNTED N/A N/A WATER DRAIN
K9300 WALL MOUNTED POWER WASHER, NEW REPLACEMENT
SIMILAR TO EXISTING
1'-0" 2'-6" 1'-0" NEW GF/CI
(INSTALL)
WALL-MOUNTED PLUG-IN GFCI (ELEC) WATER DRAIN
M2015 FLAMMABLES CABINET, FULL HEIGHT, DOUBLE DOOR,
NOT VENTED
3'6" 1'-6" 5'-5" EXISTING GF/CI
(INSTALL)
N/A N/A N/A N/A N/A
M2016 FLAMMABLES CABINET, PARTIAL HEIGHT, SINGLE DOOR,
NOT VENTED
2'-0" 1'-10" 3'-0" EXISTING GF/GI N/A N/A N/A N/A N/A
M2025 MEDICAL GAS CYLINDER METAL STORAGE RACKS WITH
NYLON STRAPS, 2X3
2'-6" 3'-2" 4'-3" NEW GF/GI N/A N/A N/A N/A N/A
M2026 MEDICAL GAS CYLINDER METAL STORAGE RACKS WITH
NYLON STRAPS, 3X3
3'-8" 3'-2" 4'-3" NEW GF/GI N/A N/A N/A N/A N/A
M2027 MEDICAL GAS CYLINDER METAL STORAGE RACKS WITH
NYLON STRAPS, 4X3
4'-10" 3'-2" 4'-3" NEW GF/GI N/A N/A N/A N/A N/A
M2028 STORAGE HOOKS FOR MEDICAL GAS CYLINDER CAPS 2'-0" 0'-10" 5'8" NEW GF/CI
(INSTALL)
WALL-MOUNTED N/A N/A N/A N/A
M2071 INDUSTRIAL HEAVY DUTY SHELVING UNIT, STEEL, SOLID
SHELVES
6'-0" 1'-6" 5'-10" EXISTING GF/GI N/A N/A N/A N/A N/A
M2081 SHELVING, WALL MOUNTED, SOLID SHELF, HEAVY DUTY,
STAINLESS STEEL
3'-0" 1'-6" 4'-0" NEW CF/CI WALL-MOUNTED N/A N/A N/A N/A
M2100 SHELVING, WIRE RACK, STAINLESS STEEL, ON CASTERS 5'-0" 1'-9" 5'-8" EXISTING GF/GI N/A N/A N/A N/A N/A
M2117 E-CYLINDER CART 2'-0" 2'-8" 2'-10" NEW GF/GI N/A N/A N/A N/A N/A
M2200 TRASH COMPACTOR, VERTICAL, WITH STORAGE
CONTAINER
5'-11" 25'-0" 8'-9" NEW GF/GI N/A HARDWIRED GFCI (ELEC) N/A N/A
M2205 HORIZONTAL CARDBOARD BALER 6'-6" 3'-1" 8'-0" NEW GF/GI N/A PLUG-IN GFCI (ELEC) N/A N/A
M2300 INDUSTRIAL FRONT LOAD WASHING MACHINE 3'-10" 5'-4" 7'-2" EXISTING GF/GI N/A PLUG-IN GFCI (ELEC) WATER DRAIN
M2400 INDUSTRIAL FRONT LOAD DRYER 3'-6" 4'-0" 5'-0" EXISTING GF/GI N/A PLUG-IN GFCI (ELEC) N/A N/A
M2650 FLOOR SCRUBBER, WALK BEHIND, BATTERY OPERATED 1'-8" 3'-10" 2'-10" EXISTING GF/GI N/A PLUG-IN GFCI (ELEC) N/A N/A
M2652 FLOOR SCRUBBER, RIDE ON, BATTERY OPERATED 3'-10" 7'-4" 4'-10" EXISTING GF/GI N/A PLUG-IN GFCI (ELEC) N/A N/A
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
B
/4
1/4" / 1'-0"
/4
1/4" / 1'-0"
/4
A-150
A. REFER TO FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION AND COORDINATION.
B. REFER TO SHEETS GI002 AND GI003 FOR ADDITIONAL INFORMATION.
C. NEW MATERIALS, INCLUDING MASONRY BRICK AND GROUT AND METAL
FINISHES, ARE TO MATCH EXISTING ADJACENT.
D. PHASING OF CONSTRUCTION AND DEMOLITION AT THE EXTERIOR SHALL BE
AS SUCH AS TO MINIMIZE DISRUPTION TO DAILY OPERATIONS.
E. EXISTING EXTERIOR SURFACES WITHIN SCOPE OF PROJECT WORK SHALL BE
POWERWASHED AND REPAIRED.
F. ROOFING MODIFICATIONS SHALL COMPLY WITH THE EXISTING ROOFING
MANUFACTURER'S ROOFING WARRANTY. WORK THAT VOIDS THE EXISTING
ROOF WARRANTY WILL NOT BE ACCEPTABLE. PROPOSED MODIFICATIONS TO
THE ROOF TO ACCOMODATE NEW WORK SHALL BE APPROVED BY THE
EXISTING ROOF SYSTEM MANUFACTURER PRIOR TO BEGINNING ANY ROOF
DEMOLITION OPERATIONS. PROVIDE MATERIALS, LABOR, AND INSTALLATION
PROCEDURES THAT WILL MAINTAIN THE EXISTING ROOF WARRANTY.
G. THE SCOPE OF THE WORK WILL INVOLVE REPAIRING THE EXISTING TPO
ROOF MEMBRANE AND PERIMETER FLASHING THAT IS AFFECTED BY
MECHANICAL EQUIPMENT INSTALLATION. THE TPO AREA OF ROOF IN
VICINITY OF NEW WORK IS TO BE POWER WASHED CLEAN PRIOR TO THE
INSTALLATION OF THE NEW WALKWAY PADS.
A
A-150
A-150
COORDINATE W/ MECH
(~ 6')
COORDINATE W/ MECH
C O
O R
D
IN
A T
E W
/ M E
C H
0'
C O
O R
D
IN
A T
E W
/ M E
C H
E Q
E Q
E Q
E Q
FIRST LEVEL
13' - 2 1/4"
A-150 A-150
A-150
FIRST LEVEL
13' - 2 1/4"
A
A-150
28 23
COORDINATE W/ MECHANICAL
COORDINATE W/ MECHANICAL
6" M
IN
1'
M
IN
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-150
ARCHITECTURAL ROOF PLAN IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 DJ CJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
24'12'6'3'1'-6"0'
P la n N or th
T ru e N or th
3/16" = 1'-0"
ARCHITECTURAL ROOF PLAN BUILDING 2 LEVEL 2
1. EXISTING DOOR TO ROOF.
2. EXISTING METAL STAIRS (NIC).
3. EXISTING WALKWAY PAD.
4. EXISTING MASONRY PARAPET AND COPING (NIC).
5. EXISTING WAREHOUSE/LOADING DOCK ROOF (NIC).
6. EXISTING EPDM ROOF ON TAPERED INSULATION. MINIMIZE DAMAGE
FROM MECH WORK.
6. EXISTING MEMBRANE ROOFING, COVER BOARD, AND TAPERED
INSULATION SYSTEM
7. EXISTING ROOF DRAIN (NIC).
8. EXISTING FAN UNIT (NIC).
9. EXISTING ROOF VENT (NIC).
10. EXHAUST FAN UNIT EF-5
11. NEW AHU.
12. NEW EPDM/TAPERED INSULATION CRICKETS AS NEEDED FOR DRAINAGE.
13. NEW WALKWAY PADS.
14. ONLY REPLACE/PATCH AS MUCH OF ROOFING SYSTEM AS NECESSARY
FOR MECHANICAL INSTALLATION.
15. BUILDING 1 LEVEL 2.
16. BUILDING 2 LEVEL 2.
17. EXISTING BRICK FACING
18. PROVIDE TERMINATION BAR, SEALANT, & COUNTER FLASHING PER
ROOFING MFR REQT.
19. ROOF MEMBRANE
20. COVER BOARD TO MATCH EXISTING
21. NEW ROOF MEMBRANE ROOFING, COVER BOARD, AND TAPERED
INSULATION SYSTEM OVER EXISTING TAPERED INSULATION TO FORM
DRAINAGE AROUND NEW ROOF CURB AND EQUIPMENT
22. EXISTING CONCRETE ROOF DECK
23. NEW MECHANICAL EQUIPMENT (SEE MECHANICAL DRAWINGS)
24. STEEL FRAMING ANGLE @ 12" OC MAX
25. CUT BACK EXISTING TAPERED ROOF INSULATION AS REQUIRED TO
INSTALL CURB BASE AND ATTACH TO CONCRETE SUBSTRATE. FILL
REMAINING VOID WITH CLOSED CELL SPRAY FOAM INSULATION
26. 2x6 PRESSURE TREATED NAILERS STACKED TO MATCH TAPERED
INSULATION WITH 1/2" EXPANSION ANCHOR (OR EPOXY ANCHOR) AT 18"
OC, TYP (TREATED PLYWOOD SHIMS MAY BE USED TO ACCOMMODATE
ROOF SLOPE)
27. WRAP ROOF MEMBRANE OVER TOP OF CURB AND FASTEN TO BACK SIDE
OF ROOF CURB AT 6" OC MAX WITH CONTINUOUS 16 GAUGE GALVANIZED
STEEL STRAP.
28. 4x12 ROOF CURB FRAMING
29. 18 GUAGE GALVANIZED STEEL INSULATED CURB FOR SINGLE-PLY
ROOFING
30. PLYWOOD (SHIMMED TO MATCH ROOF SLOPE)
31. GASKET (CONTINUOUS)
32. 2x10 PRESSURE TREATED NAILERS STACKED TO MATCH TAPERED
INSULATION WITH 1/2" EXPANSION ANCHOR (OR EPOXY ANCHOR) AT 18"
OC, TYP (TREATED PLYWOOD SHIMS MAY BE USED TO ACCOMMODATE
ROOF SLOPE)
33. EXISTING MEMBRANE ROOFING, COVER BOARD, AND TAPERED
INSULATION SYSTEM
24'12'6'3'1'-6"0'
P la n N or th
T ru e N or th
1/4" = 1'-0"
AHU ROOF CURB FRAMING PLAN
6'3'1'-6"9"4"0'
3/4" = 1'-0"
ROOF SECTION
24'12'6'3'1'-6"0'
1/4" = 1'-0"
AHU ROOF CURB SECTION
3'1'-6"8"4"2"0'
1 1/2" = 1'-0"
ROOF CURB DETAIL
3'1'-6"8"4"2"0'
1 1/2" = 1'-0"
ROOFING TERMINATION @ WALL
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
BASEMENT LEVEL
0"
FIRST LEVEL
13' - 2 1/4"
A B C1 C D
A-310
A-310
A-310
SECOND LEVEL
26' - 4 1/2"
12 2
A-320
A-320
A-320
A-321
A-320
50' - 9"
19' - 11" 11' - 0" 9' - 6" 10' - 4"
BUILDING 2 TOP OF
BRICK/PRECAST
29' - 1 9/16"
BUILDING 2 LEVEL 2
13' - 2"
BUILDING 1 BASEMEMT LEVEL
0"
BUILDING 2 UPPER ROOF
DECK
27' - 1 9/16"
A. REFER TO FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION AND COORDINATION.
B. REFER TO SHEETS GI002 AND GI003 FOR ADDITIONAL INFORMATION.
C. NEW MATERIALS, INCLUDING MASONRY BRICK AND GROUT AND METAL
FINISHES, ARE TO MATCH EXISTING ADJACENT.
D. PHASING OF CONSTRUCTION AND DEMOLITION AT THE EXTERIOR SHALL BE
AS SUCH AS TO MINIMIZE DISRUPTION TO DAILY OPERATIONS.
E. EXISTING EXTERIOR SURFACES WITHIN SCOPE OF PROJECT WORK SHALL BE
POWERWASHED AND REPAIRED WHERE STAINED, EFFLORESCING, CHIPPED,
CRACKED, SPALLING, DENTED, ETC. AS DETERMINED BY VHA COR. THIS
SCOPE OF WORK WILL INVOLVE POWER WASHING THE CONCRETE IN THE
GROUND AREA OF THE NEW TRASH COMPACTOR INCLUDING FOUNDATION
WALL, ALL MASONRY FROM THE BUILDING 1 BASEMENT LEVEL UP TO
BUILDING 2 LEVEL 2 BETWEEN COLUMN LINES A AND C1. METAL PANELS
WALLS IN THIS VICINITY TO ALSO BE POWER WASHED AT DISCRETION OF
THE COR. AS MASONRY IS BEING AFFECTED, NEW BRICKS TO BE SPLICED IN
AND TUCKPOINTING TO BE DONE AS REQUIRED, AND ANY DAMAGED
MASONRY AND GROUT RESULTING FROM THIS WORK TO BE REPAIRED OR
REPLACED TO ORIGINAL CONDITIONS AS ACCEPTABLE TO THE COR.
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-210
EXTERIOR ELEVATIONS IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
12'6'3'1'-6"9"0'
3/8" = 1'-0"
WEST ELEVATION
1. EXISTING BUILDING 36. METAL BUILDING.
2. EXISTING BRICK MASONRY VENEER.
3. EXISTING CONCRETE FOUNDATION WALL.
4. EXISTING LADDER ENCLOSURE (N.I.C.)
5. FACE OF EXISTING BUILDING 2 WALL (N.I.C.)
6. NEW MASONRY INFILL TO MATCH EXISTING EXTERIOR MASONRY WALL
EXACTLY.
7. NEW EXHAUST FAN.
8. NEW EXTERIOR GRADE LOCKABLE ACCESS DOOR FOR GREASE
INTERCEPTOR VACUUM HOSE DARK BRONZE PVDF PAINT FIISH.
9. NEW OSHA COMPLIANT ACCESS DOORS FOR TRASH COMPACTOR.
EQUIPMENT ITEM TIED TO COMPACTOR. DARK BRONZE PVDF PAINT FINISH
TO MATCH EXISTING.
10. REPLACE ENTIRE VERTICAL METAL WALL PANEL WHERE EXISTING DRYER
VENT IS REMOVED. METAL PANEL TO MATCH EXISTING ADJACENT. V.I.F.
11. NEW DRYER VENT EXHAUST TO BE RUN THROUGH EXISTING BUILDING 36.
REPLACE ENTIRE VERTICAL METAL WALL PANEL WHERE NEW DRYER VENT
IS INSTALLED. METAL PANEL TO MATCH EXISTING ADJACENT V.I.F.
12. EXISTING TRASH COMPACTOR/STORAGE.
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
BASEMENT LEVEL
0"
FIRST LEVEL
13' - 2 1/4"
A-540
A-540
A. REFER TO FIRE PROTECTION, MECHANICAL, PLUMBING, AND ELECTRICAL
SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION AND
COORDINATION.
B. REFER TO SHEETS GI002 AND GI003 FOR ADDITIONAL INFORMATION.
C. FIRE-RESISTANCE RATED PARTITIONS TO EXTEND TO UNDERSIDE OF ONE
WAY BEAM AND SLAB CONCRETE STRUCTURE WITH JOINT SEALANTS AT TOP
OF PARTITION. REFER TO SPECIFICATION SECTION 061000 AND
SPECIFICATION SECTION 079200.
D. PAINT ALL EXPOSED CMU WALLS ABOVE FRP WALL PROTECTION PANELS
PNT-2.
E. SEAL ALL INTERIOR AND EXTERIOR WALL PENETRATIONS.
F. INFILL FLOOR WITH CONCRETE FLUSH TO ADJACENT FLOOR LEVEL WHERE
EXISTING WALLS WERE REMOVED.
G. EXISTING WALL FINISH IN POWER WASH ROOM BS05 IS CERAMIC GLAZED
FACING BRICK (CGFB-1); ASTRA-GLAZE-SW+ RECYCLED GLAZED CONCRETE
MASONRY UNITS; TRENWYTH 'SAND'; 7-3/4" X 15-3/4" SIZE. COMPANY CAN
MAKE CUSTOM COLORS IF THIS COLOR IS NO LONGER AVAILABLE AS A
STANDARD COLOR.
H. EXISTING METAL PANELS ON BUILDING 36 ARE SIMILAR TO FABRAL ULTRA
RIB EXPOSED FASTENER ROOFING AND SIDING PANEL; DARK BRONZE (BASIS
OF DESIGN). VERIFY IN FIELD.
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-321
WALL SECTIONS IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
3/4" = 1'-0"
DRYER VENT LOCATION THROUGH BUILDING 36
1 EXISTING PREFABRICATED METAL STORAGE BUILDING (BUILDING 36).
2 EXISTING EXTERIOR CMU AND BRICK VENEER WALL.
3 EXISTING CONCRETE STRUCTURE.
4 NEW DRYER VENT DUCT TO OUTSIDE (SEE MECHANICAL DRAWINGS).
5 EXISTING OVERHEAD GARAGE DOOR BEYOND (EXTENDS UP WALL TO
CEILING).
6 RENOVATED EMS LAUNDRY AREA.
7 REPLACE ENTIRE METAL PANEL AT LOCATION OF NEW DUCT
PENETRATION. MATCH EXISTING ADJACENT.
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
A. REFER TO FIRE PROTECTION, MECHANICAL, PLUMBING, AND ELECTRICAL
SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION AND
COORDINATION.
B. REFER TO SHEETS GI002 AND GI003 FOR ADDITIONAL INFORMATION.
C. FIRE-RESISTANCE RATED PARTITIONS TO EXTEND TO UNDERSIDE OF ONE
WAY BEAM AND SLAB CONCRETE STRUCTURE WITH JOINT SEALANTS AT TOP
OF PARTITION. REFER TO SPECIFICATION SECTION 061000 AND
SPECIFICATION SECTION 079200.
D. PAINT ALL EXPOSED CMU WALLS ABOVE FRP WALL PROTECTION PANELS
PNT-2.
E. SEAL ALL INTERIOR AND EXTERIOR WALL PENETRATIONS.
F. INFILL FLOOR WITH CONCRETE FLUSH TO ADJACENT FLOOR LEVEL WHERE
EXISTING WALLS WERE REMOVED.
G. EXISTING WALL FINISH IN POWER WASH ROOM BS05 IS CERAMIC GLAZED
FACING BRICK (CGFB-1); ASTRA-GLAZE-SW+ RECYCLED GLAZED CONCRETE
MASONRY UNITS; TRENWYTH 'SAND'; 7-3/4" X 15-3/4" SIZE. COMPANY CAN
MAKE CUSTOM COLORS IF THIS COLOR IS NO LONGER AVAILABLE AS A
STANDARD COLOR.
H. EXISTING METAL PANELS ON BUILDING 36 ARE SIMILAR TO FABRAL ULTRA
RIB EXPOSED FASTENER ROOFING AND SIDING PANEL; DARK BRONZE (BASIS
OF DESIGN). VERIFY IN FIELD.
A
A-411 54
M8A.1
36" CLEAR HOLD
C
LE
A R
H O
LD
A-511
M2081
FRP-1
CR-1
CR-1
M2650
HR-1HR-1
A-630
SIM
CR-1
CR-1
4'
CR-1
2'
8"
FRP-1
A-4119
B S
M8E.1
M2026
M2027
M2117
M2025 M2027
M2028
FEC
10 1
M2026
M2117
FEC
M2028
BS10
M2028
M2027
FRP-1
1'
M2025 M2027
M2117
FRP-1
M2027 M2026
FRP-1
A-411
13 12
32" CLEARANCE
3'
B E
H
IN
D D
R Y
E R
C
LE
A R
H O
LD
M2400 M2300
FEC
HR-1
HR-1
CR-1
CR-1
CR-1
CR-1
K2021
CR-1
CR-1
FRP-1
M2081
M2400
CLEAR HOLD
3' - 0"
HR-1HR-1
FRP-1
HR-1
HR-1
M2300
M2400
K2021
CR-1
CR-1
OPEN
A-630
FRP-1
FEC
CR-1
CR-1
HR-1HR-1
FRP-1
OPEN
K2021
INTERIOR FINISH LEGEND
FLOORING
LVT-1 TO MATCH EXISTING ADJACENT: LUXURY VINYL TILE; TANDUS
CENTIVA EVENT SERIES CLASSIC STONE OKARA GRAY ECL 7126
RES-1 RESINOUS FLOORING; DUR-A-FLEX POLY-CRETE MDQ Q28-23,
ARMOR TOP GLOSS
RES-2 RESINOUS FLOORING; DUR-A-FLEX POLY-CRETE MDQ Q28-17,
ARMOR TOP GLOSS (FOR YELLOW BORDER AT EMERG. SHOWER)
SC-1 SEALED CONCRETE
VCT-1 TO MATCH EXISTING ADJACENT: VINYL FLOOR TILE; ARMSTRONG
STANDARD EXCELON IMPERIAL TEXTURE COTTAGE TAN 51830
BASE
RB-1 RESILIENT BASE; TO MATCH EXISTING ADJACENT (ROPPE P193
BLACK BROWN, VIF); 4" TALL
RB-2 RESILIENT BASE; ROPPE P193 BLACK BROWN, VIF); 6" TALL
RESB-1 BUILT-UP RESINOUS FLOORING; 6" TALL ; DUR-A-FLEX POLY-CRETE
MDQ Q28-23, ARMOR TOP GLOSS ; ZINC CAP STRIP
CEILING
AT ARMSTRONG - WHITE / TEGULAR - CIRRUS #584
PNT-1 SHERWIN WILLIAMS - SW7036 ACCESSIBLE BEIGE
PNT-2 SHERWIN WILLIAMS - SW6105 DIVINE WHITE
WALLS
CGFB-1 ASTRA-GLAZE-SW+ RECYCLED GLAZED CMU; TRENWYTH 'SAND'
PNT-1 SHERWIN WILLIAMS - SW7036 ACCESSIBLE BEIGE
PNT-2 SHERWIN WILLIAMS - SW6105 DIVINE WHITE
WALL PROTECTION
CG-01 CORNER GUARD, RESIN, FULL HEIGHT. TO MATCH EXISTING
CG-02 CORNER GUARD, FULL HEIGHT. STAINLESS STEEL, 304, #4 FINISH
EG-1 END GUARD, FULL HEIGHT. STAINLESS STEEL, 304, #4 FINISH
CR-1 CRASH RAIL, RESIN. INPRO - NUTREE BLACK; 8" TALL
HR-1 HAND RAIL, RESIN. INPRO - BLACK, 5 1/2" TALL
FRP-1 FIBERGLASS WALL PROTECTION, CLASS A, .090" THICK, FULL
HEIGHT, MARLITE FRP P-145 SILVER
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-411
ENLARGED PLANS & ELEVATIONS IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
04/18/2023 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
1. EXISTING MEDICAL GAS MANIFOLDS;REINSTALLED IN EXISTING PLACE
AFTER RENOVATION.
2. NEW RESILIENT FLOORING TO MATCH EXISTING ADJACENT..
3. GUARD; SHOP PAINTED.
4. EXISTING GREASE INTERCEPTOR TO REMAIN IN OPERATION DURING
CONSTRUCTION. PROTECT AND KEEP ACCESS UNOBSTRUCTED.
5. NEW LOCKABLE EXTERIOR GRADE ACCESS DOOR FOR GREASE
INTERCEPTOR HOSE.
6. NEW OSHA COMPLIANT COMPACTOR DOOR.
7. NEW 6"X6" CONCRETE CURB.
8. EXHAUST VENT 12" FROM FLOOR
9. GYPSUM BOARD SOFFIT.
10. NEW MEDICAL GAS MANIFOLD TO REPLACE EXISTING IN KIND.
11. NEW LOW AIR EXHAUST.
3/8" = 1'-0"
ENLARGED PLAN - GREASE INTERCEPTOR
3/8" = 1'-0"
ELEV - GREASE INTERCEPTOR
3/8" = 1'-0"
ELEV - GREASE INTERCEPTOR
4 3/8" = 1'-0"
ENLARGED PLAN - MED GAS MANIFOLDS
3/8" = 1'-0"
MED GAS MANIFOLDS BS10B SOUTH ELEVATION
63/8" = 1'-0"
MED GAS MANIFOLDS BS10B WEST ELEVATION
73/8" = 1'-0"
MED GAS MANIFOLDS BS10 NORTH ELEVATION
3/8" = 1'-0"
MED GAS MANIFOLDS BS10B EAST ELEVATION
3/8" = 1'-0"
ENLARGED PLAN - LAUNDRY
3/8" = 1'-0"
LAUNDRY BS05B LAUNDRY EAST ELEVATION
13 3/8" = 1'-0"
LAUNDRY BS05B LAUNDRY NORTH ELEVATION
11 3/8" = 1'-0"
LAUNDRY BS05B LAUNDRY SOUTH ELEVATION
103/8" = 1'-0"
LAUNDRY BS05B LAUNDRY WEST ELEVATION
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
A. REFER TO SHEET GI001 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
B. WHERE “ACOUSTIC SEALANT” IS INDICATED ON WALL TYPES: PROVIDE
ACOUSTIC (SOUND) SEALANT ABOVE TOP TRACK, UNDER BOTTOM TRACK,
AND AT PENETRATIONS (BOTH SIDES).
C. WHERE JOINT SEALANTS ARE INDICATED ON WALL TYPES: PROVIDE FIRE-
RATED SEALANT ABOVE TOP TRACK, UNDER BOTTOM TRACK, AT
PENETRATIONS (BOTH SIDES), AND AS REQUIRED BY FIRE RATING UL
NUMBER.
D. EXTEND FIRE-RATED WALL CONSTRUCTION BEHIND RECESSED OR BUILT-IN
EQUIPMENT; SUCH AS FIRE EXTINGUISHER CABINETS (FEC), ELECTRICAL
WATER COOLERS (EWC), ELECTRICAL PANELS, ETC., UNLESS NOTED
OTHERWISE.
E. PROVIDE AND INSTALL STIFFENERS, BRACING, BACK-UP PLATES AND
SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF CASEWORK
AND OF FLOOR MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL OR
LABORATORY EQUIPMENT.
F. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS
PENETRATE PARTITIONS: STUDS SHALL BE BRACED AND FRAMED TO
STRUCTURE, AS REQUIRED, TO PROVIDE ADEQUATE SUPPORT.
PENETRATIONS THROUGH ACOUSTICAL AND FIRE RATED WALLS SHALL BE
SEALED TO PROVIDE FIRE, SMOKE, AND/OR ACOUSTICAL ISOLATION OF
SPACES WITH APPROPRIATE ACOUSTICAL/ FIRESTOP MATERIAL.
G. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL, TELEPHONE, OR OTHER
OUTLETS, EXCEPT WHERE SPECIFICALLY SHOWN.
H. WALL BASE IS NOT SHOWN ON PARTITION TYPES FOR CLARITY. REFER TO
FINISH SCHEDULE.
I. PROVIDE GLASS-MAT, WATER RESISTANT BACKING BOARD AT WET
LOCATIONS.
J. EXCEPT AT FIRE-RATED PARTITIONS, WALL AND COLUMN GYPSUM BOARD
FACING SHALL BE HELD AT 5/8 INCH BELOW STRUCTURE, UNLESS NOTED OR
SHOWN OTHERWISE.
K. PROVIDE HI ABUSE (PURPLE BOARD) INTERIOR GYPSUM BOARD AT THE
INTERIOR SIDE OF EXTERIOR WALLS.
L. WALL ASSEMBLIES THAT REQUIRE AN STC RATING SHALL HAVE A MINIMUM
STC RATING OF NOT LESS THAN 45, UNLESS NOTED OTHERWISE.
NON-RATED WALL ASSEMBLY
Z-FURRING AS SPECIFIED
SOUND ATTENUATING INSULATION AS
SPECIFIED
1 LAYER 5/8" TYPE 'X' GWB
R E
: S C
H E
D
5/8" TYPE 'X' GYPSUM WALL BOARD
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT INSULATION AS SPECIFIED
CONTINUOUS METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
FINISHED
FLOOR
FINISHED CEILING HT
RE: RCP
BOTTOM OF STRUCTURE
PLAN VIEW
Z-FURRING
F#A.X
WALL TYPE F#A.X
TYPE WALL DESCRIPTION
F2A.A
FURRING WALL:
• 2-1/2" 20 GA Z-FURRING
• TO B.O. OF DECK OR ROOF ABOVE
• 5/8" TYPE "X" GWB AT FACE OF WALL TO DECK ABOVE
• ACOUSTIC INSULATION
• NON RATED
GYPSUM BOARD (09 29 00) ON ONE SIDE OF NON-
STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE
OF FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
F2A
CHANNEL SIZE
2-1/2"
STC RATING
N/A
FRR TEST
N/A
HEAD DETAIL
BASE DETAIL
PARTITION WIDTH
3 1/8"
09 22 16
SPACING PER
PLAN VIEW
SECTION VIEW
FINISHED CEILING HT
RE: RCP
BOTTOM OF STRUCTURE
FINISHED CEILING HT
RE: RCP
BOTTOM OF STRUCTURE
FINISHED
FLOOR
FINISHED
FLOOR
FINISHED
FLOOR
CONCRETE MASONRY UNIT WALL, BOTTOM TWO ROWS
GROUTED, REINFORCEMENT PER STRUCTURAL, 3/8"
RAKED JOINTS.
PARTITION TYPE
M6A M8A
NOMINAL WIDTH
6" 8"
STC RATING
FRR TEST
UL XXX
UL XXX
HEAD DETAIL
BASE DETAIL
M#A.X
ACTUAL WIDTH
5 5/8" 7 5/8"
WALL TYPE M#.A.X
TYPE WALL DESCRIPTION
M6A
M8A
M8A.1
MASONRY BLOCK WALL:
• 6" CMU BLOCK
• TO B.O. OF DECK OR ROOF ABOVE
• NON RATED
MASONRY BLOCK WALL:
• 8" CMU BLOCK
• TO B.O. OF DECK OR ROOF ABOVE
• NON RATED
MASONRY BLOCK WALL:
• 8" CMU BLOCK
• TO B.O. OF DECK OR ROOF ABOVE
• 1-HR FIRE RATING
CEILING AS INDICATED ON RCP
L3x2x3/16 LLV, CONT W/ 3/8" EXP ANCHOR @
2'-0" OC (3" MIN EMBED), TYP EA SIDE OF WALL
RE: SCHED
R E
: S C
H E
D
FIRE STOPPING AT RATED WALL
1"
5/8" EXP ANCH @ 1'-4" OC (3" MIN EMBED)
1/
2"
EQ EQ
5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION AS
SPECIFIED
CONT METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
FINISHED
FLOOR
FINISHED CEILING HT
RE: RCP
BOTTOM OF STRUCTURE
RE: SCHED
G A
P 1"
S
LI
P
SLIP CHANNEL
SEALANT
R E
: S C
H E
D
PLAN VIEW
METAL STUDS WITH HORIZONTAL BRACING AS REQD
S#A.X
WALL TYPE S#A.X
TYPE WALL DESCRIPTION
S3A.A.1
STANDARD STUD WALL:
• 3-5/8" 20 GA METAL STUD
• TO B.O. OF DECK OR ROOF ABOVE
• 5/8" TYPE "X" GWB EACH SIDE TO DECK ABOVE
• ACOUSTIC INSULATION
• 1-HR FIRE RATING
GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-
STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE
OF FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
S3A
STUD SIZE
3-5/8"
STC RATING
FRR TEST
UL XXX
HEAD DETAIL
BASE DETAIL
PARTITION WIDTH
4-7/8"
1 HR RATED WALL ASSEMBLY
UL ASSEMBLY # U419
METAL STUD AS SPECIFIED
SOUND ATTENUATION INSULATION AS SPECIFIED
1 LAYER 5/8" GWB EACH SIDE (TYPE 'X' FOR RATING)
2 LAYERS 5/8" GWB EACH SIDE (TYPE 'X' FOR 2HR
RATING)
09 22 16
SPACING PER
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-610
WALL TYPE SCHEDULE IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
09/03/2021 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
INTERIOR FINISH LEGEND
FLOORING
LVT-1 TO MATCH EXISTING ADJACENT: LUXURY VINYL TILE; TANDUS
CENTIVA EVENT SERIES CLASSIC STONE OKARA GRAY ECL 7126
RES-1 RESINOUS FLOORING; DUR-A-FLEX POLY-CRETE MDQ Q28-23,
ARMOR TOP GLOSS
RES-2 RESINOUS FLOORING; DUR-A-FLEX POLY-CRETE MDQ Q28-17,
ARMOR TOP GLOSS (FOR YELLOW BORDER AT EMERG. SHOWER)
SC-1 SEALED CONCRETE
VCT-1 TO MATCH EXISTING ADJACENT: VINYL FLOOR TILE; ARMSTRONG
STANDARD EXCELON IMPERIAL TEXTURE COTTAGE TAN 51830
BASE
RB-1 RESILIENT BASE; TO MATCH EXISTING ADJACENT (ROPPE P193
BLACK BROWN, VIF); 4" TALL
RB-2 RESILIENT BASE; ROPPE P193 BLACK BROWN, VIF); 6" TALL
RESB-1 BUILT-UP RESINOUS FLOORING; 6" TALL ; DUR-A-FLEX POLY-CRETE
MDQ Q28-23, ARMOR TOP GLOSS ; ZINC CAP STRIP
CEILING
AT ARMSTRONG - WHITE / TEGULAR - CIRRUS #584
PNT-1 SHERWIN WILLIAMS - SW7036 ACCESSIBLE BEIGE
PNT-2 SHERWIN WILLIAMS - SW6105 DIVINE WHITE
WALLS
CGFB-1 ASTRA-GLAZE-SW+ RECYCLED GLAZED CMU; TRENWYTH 'SAND'
PNT-1 SHERWIN WILLIAMS - SW7036 ACCESSIBLE BEIGE
PNT-2 SHERWIN WILLIAMS - SW6105 DIVINE WHITE
WALL PROTECTION
CG-01 CORNER GUARD, RESIN, FULL HEIGHT. TO MATCH EXISTING
CG-02 CORNER GUARD, FULL HEIGHT. STAINLESS STEEL, 304, #4 FINISH
EG-1 END GUARD, FULL HEIGHT. STAINLESS STEEL, 304, #4 FINISH
CR-1 CRASH RAIL, RESIN. INPRO - NUTREE BLACK; 8" TALL
HR-1 HAND RAIL, RESIN. INPRO - BLACK, 5 1/2" TALL
FRP-1 FIBERGLASS WALL PROTECTION, CLASS A, .090" THICK, FULL
HEIGHT, MARLITE FRP P-145 SILVER
BASEMENT LEVEL
0"
8"
1/ 2"
2'
/2
2'
8"
1' - 8"
4'
3'
4'
M2081
HR-1
HR-1
FRP-1
CR-1
HR-1
HR-1
CONCRETE FLOOR
RESILIENT
FLOORING
AS SCH.
JOHNSONITE SSR-XX-B,
COLOR TO MATCH ADJ.
WALL BASE
1/ 4"
1 3/4"
RESINOUS FLOORING,
PER SCHEDULE
VCT OR LVT, PER
SCHEDULE
NO TRANSITION STRIP;
BUTT JOINT AND SEALANT
CENTER TRANSITION
WITH DOOR WHERE
APPLICABLE
STAINLESS STEEL CAPPING STRIP
INTEGRAL RESINOUS BASE, PER
SCHEDULE
RESINOUS FLOORING, PER
SCHEDULE
CANT STRIP
A S
S C
H E
D U
LE
D
R 1"
SILICONE SEALANT, CLEAR
WALL CLADDING, PER SCHEDULE
J-MOLDING BY WALL CLADDING
MANUFACTURER, PER SCHEDULE
RESILIENT BASE TO
MATCH EXISTING
RESILIENT FLOORING
OR SEALED
CONCRETE FLOOR
A S
S C
H E
D U
LE
D
HR-1 (HAND RAIL)
METAL STUD FRAMING; 25
GAUGE MIN. BACKING AS
REQUIRED AT METAL STUD
LOCATIONS
BASE AS SCHEDULED
FLOOR COVERING AS
SCHEDULED
METAL STUD FRAMING; 25
GAUGE MIN. BACKING AS
REQUIRED
CR-1 (CRASH RAIL)
5 1/2 "
3' -2
O
R M
A T
C H
E X
IS
T
IN
G
A D
JA
C
E N
T
8" 8"
1-1/4" STD. STEEL PIPE
RAIL, WELDED, TYP
GUARD POST
BEYOND
E X
IS
T
E Q
E Q
M
IN
6"
STEEL PLATE BOLTED
INTO CURB; BOLTS
EPOXIED
FLOOR FINISH,
RE: FINISH PLAN
CHAMFERED CORNER
M A
X
6"
CONCRETE CURB
CORE INTO EXISTING SLAB
FOR POSTS; EPOXY GROUT
1-1/4" STD. STEEL
PIPE RAIL,
WELDED, TYP
GUARD POST
(END POSTS
PLUS ONE IN
CENTER OF
RAIL)
E X
IS
T
E Q
E Q
M
IN
STEEL PLATE BOLTED
INTO FLOOR SLAB;
BOLTS EPOXIED
FLOOR FINISH,
RE: FINISH PLAN
M A
X
CORE INTO EXISTING SLAB
FOR POSTS; EPOXY GROUT
5"
/2
/2
/2
/2
4"
2"
DISTANCE
OF GUARD
POST FROM
WALLS, TYP
3" 2"
1/8" THICK STEEL
PLATE, WELDED
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_A R
C H
_R
_d jo hn so nQ P
A E
4.
rv t
/2 /2
:0
9:
A M
A-630
ROOM FINISH SCHEDULE AND
TYPICAL FINISH DETAILS
IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
09/03/2021 TW DJ
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
FINISH SCHEDULE
ROOM
NUMBER
ROOM NAME
FLOORS WALLS
CEILING
WALL PROTECTIONFLOOR BASE NORTH EAST SOUTH WEST
131 MED GAS STOR SC RB-2 PNT-2 PNT-2 PNT-2 PNT-2 AT SEE PLAN; ELEVATIONS
BCS03 CORRIDOR
EXIST/NEW
VCT-1 TO
MATCH
EXIST
RB-1 PNT-1 PNT-1 PNT-1 PNT-1 AT/GWB/PNT-1
SEE PLAN; ELEVATIONS
BCS05 CORRIDOR
EXIST/ NEW
LVT-1 TO
MATCH
EXIST
RB-1 PNT-1 PNT-1 PNT-1 PNT-1 AT/GWB/PNT-1
SEE PLAN; ELEVATIONS
BS03 HAZARDOUS STORAGE RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 AT SEE PLAN; ELEVATIONS
BS05 POWER WASH RES-1 RESB-1 EXISTING EXISTING EXISTING EXISTING GWB/PNT-2 SEE PLAN; ELEVATIONS
BS05A PUMP ROOM RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 OTS/PNT-2 SEE PLAN; ELEVATIONS
BS07 COMPACTOR ROOM RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 OTS/GWB/PNT-2 SEE PLAN; ELEVATIONS
BS07A GREASE INTERCEPTOR RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 OTS/PNT-2 SEE PLAN; ELEVATIONS
BS07B LAUNDRY RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 GWB/PNT-2 SEE PLAN; ELEVATIONS
BS07C EQMT STORAGE RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 OTS/PNT-2 SEE PLAN; ELEVATIONS
BS08 SOILED LINEN RES-1 RESB-1 PNT-2 PNT-2 PNT-2 PNT-2 AT SEE PLAN; ELEVATIONS
BS09 ELEC SC RB-2 PNT-2 PNT-2 PNT-2 PNT-2 OTS/PNT-2 SEE PLAN; ELEVATIONS
BS10 MED GAS MANIFOLDS SC RB-2 PNT-2 PNT-2 PNT-2 PNT-2 AT SEE PLAN; ELEVATIONS
1 1/2" = 1'-0"
SECTION THROUGH STAINLESS STEEL STANDARD & BRACKET SHELVES (CFCI)
3" = 1'-0"
SEALED CONCRETE TO RESILIENT FLOORING
8 3" = 1'-0"
RESINOUS FLOORING TO RESILIENT FLOORING
7 3" = 1'-0"
RESINOUS BUILT UP BASE DETAIL
6 3" = 1'-0"
RESILIENT BASE DETAIL
3" = 1'-0"
HAND RAIL AND CRASH RAIL - DETAIL AT CORRIDOR AND SELECT LOCATIONS WITHIN EMS AREA 3 1 1/2" = 1'-0"
GUARD AND CONCRETE CURB DETAIL
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
1 1/2" = 1'-0"
GUARD DETAIL
STEAM TRAP SCHEDULE
MARK LOCATION
SYSTEM AND/OR
SERVICE
CAPACITY AT MIN DIFF
PRESS
MIN DIFF PRESS MIN INLET PRESS
TRAP TYPE
TRAP SIZE MANUFACTURER AND MODEL (OR
APROVED EQUAL)
NOTES
LBS/HR PSI PSI IN
50-ST-1 AHU-B7 PREHEAT COIL 750 0.25 2.00 F&T 1 1/4 ARMSTRONG CS SERIES 1, 2
50-ST-2
CORRIDOR
BCS05
END-OF-LINE DRIP 3 0.25 2.00
INVERTED
BUCKET
3/4 ARMSTRONG 981 1, 2
NOTES:
1. A SAFETY FACTOR OF 2.5:1 WAS APPLIED TO ALL STEAM CAPACITIES.
2. FIELD TO PROVIDE BACKFLOW PREVENTER.
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Number:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Revision:
C :\R ev it
\2 0.
_W as te
_M E
P _R
_r th or nb ru gh S
6J X
V .r vt 9/
/2
3:
:5
P M
M-601
MECHANICAL EQUIPMENT
SCHEDULES
IMPROVE SITE WASTE
MANAGEMENT
601 US-6 W, IOWA CITY, IA 52246
636-805
09/03/2021 MB ANT
100% CONSTRUCTION
DOCUMENTS
VEG 20.26
FINAL DRAWINGS FOR CONSTRUCTION
TERMINAL UNIT SCHEDULE
MARK
UNIT
SIZE
EAT
°F
LAT
°F
AIR FLOW REHEAT COIL
MANUFACTURER AND
MODEL
REMARKSHEATING
CFM
MAX APD (IN
WG)
EWT
(°F)
LWT
(°F)
HEATING
COIL MBH
GPM
FLUID
PRESSURE
DROP (IN WG)
CV-1 6 55 80 390 0.5 180 150 10.6 0.7 0.28 PRICE SDV5 -
CV-2 6 55 75 350 0.5 180 150 7.6 0.5 0.11 PRICE SDV5 -
CV-3 6 55 75 240 0.5 180 159 5.3 0.5 0.04 PRICE SDV5 -
CV-4 6 55 75 530 0.5 180 156 11.6 1.0 0.49 PRICE SDV5 -
CV-5 12 55 80 1330 0.5 180 167 36.1 5.5 3.17 PRICE SDV5 -
EXHAUST FAN SCHEDULE
MARK LOCATION
AIRFLOW
(CFM)
TSP (IN
WG)
FAN MOTOR
MANUFACTURER AND MODEL
TYPE DRIVE MAX RPM HP
NOMINAL
BHP
PHASE VOLTAGE
SPEED
CONTROL
EF-5 BUILDING 1 2290 0.1
WALL MOUNTED
UPBLAST
DIRECT 841 1/2 0.22 1 120 ECM
GREENHECK CUE-160-VG. PROVIDE WITH INLET GUARD AT WALL FACE. PROVIDE WALL-MOUNT
FLANGED CURB AND HARDWARE. SIZE CURB DEPTH FOR FIELD-VERIFIED WALL THICKNESS.
EF-4 BUILDING 1 1540 0.5 UPBLAST ROOF DIRECT 860 1/3 0.23 1 120 ECM GREENHECK CUE-160-C. PROVIDE ROOF CURB ADAPTER.
AIR DEVICE SCHEDULE
MARK
TYPE
DESCRIPTION
MOUNTING
PANEL/FRAME
SIZE
NECK SIZE DAMPER FINISH
MODEL (OR
APPROVED EQUAL)
EG-1 SIDEWALL WALL/DUCT 6" X 6" 6" X 6" YES WHITE PRICE 710Z
EG-3 DUCT MOUNTED DUCT 14" X 14" 12" X 12" YES WHITE PRICE 510Z
EG-4 LAY-IN CEILING 24" X 24" 10" NO WHITE PRICE 80SR
EG-5 HARD CEILING CEILING 12" X 12" 10" NO WHITE PRICE 710Z
SD-1 HARD CEILING CEILING 24" X 24" 8" NO WHITE PRICE SCD
SD-1 HARD CEILING CEILING 24" X 24" 6" NO WHITE PRICE SCD
SG-1 DUCT MOUNTED DUCT 10" X 6" 10" X 6" NO WHITE PRICE 530
SG-3 HARD CEILING CEILING 12" X 12" 10" NO WHITE PRICE 710Z
AIR HANDLING UNIT SCHEDULE
MARK
MIN OA
(CFM)
OVERALL
HEIGHT (IN)
OVERALL
LENGTH (IN)
OVERALL
WIDTH (IN)
SUPPLY FAN PREFILTER 1 PREFILTER 2
MANUFACTURER AND MODEL (OR APPROVED EQUAL)
AIRFLOW (CFM) TSP (IN WG) ESP (IN WG) WHEEL (TYPE) DRIVE VFD FAN RPM FAN QTY
MOTOR HP
(EACH)
PHASE
FREQUE
NCY
VOLTAGE
MOTOR FLA
(EACH)
MERV
THICKNESS
(IN)
FINAL APD
(IN WG)
MERV
THICKNESS
(IN)
FINAL APD
(IN WG)
AHU-B7 3860 48 216 45 3860 4.25 0.75 CENTRIFUGAL DIRECT YES 2078 1 5 3 60 460 6.70 8 2 0.51 11 2X2 1.02 YORK XTO-48x45
MARK
CHILLED WATER COIL INTEGRAL FACE AND BYPASS STEAM PREHEAT COIL
MAX FV
(FT/MIN)
MAX TOTAL
APD (IN W.G.)
EAT-DB (°F) EAT-WB (°F) LAT-DB (°F) LAT-WB (°F)
PROPYLENE GLYCOL
CONTENT
EWT (°F) LWT (°F)
MAX TOTAL
WPD (FT)
FLOW RATE
(GPM)
HEATING
AIRFLOW (CFM)
MAX FV
(FT/MIN)
MAX APD
(IN WG)
EAT-DB
(°F)
LAT-DB
(°F)
MBH
PRESSURE
(PSI)
FLOW RATE
(LB/HR)
AHU-B7 444 0.71 91.1 75.9 54.8 54.4 0% 45.00 55 10.1 53.9 3860 704 0.48 -4.1 63.8 283.1 15 299
NOTES:
1. PERFORMANCE SHOWN SHALL BE RATED AT 670 FT ELEVATION.
2. UNIT SHALL SHALL BE DRAW THROUGH CONFIGURATION.
3. STEAM PREHEAT COIL PRESSURE SHOWN IS UPSTREAM OF CONTROL VALVE. SIZE CONTROL VALVE DIFFERENTIAL PRESSURE ACCORDINGLY.
4. UNIT SHALL HAVE A SINGLE POINT THROUGH-BASE ELECTRICAL POWER CONNECTION.
5. UNIT SHALL INCLUDE BACK TO BACK PREFILTERS.
6. PROVIDE VFD NEMA 3R WITH BYPASS IN CONDITIONED ENCLOSURE.
7. PROVIDE UL 268 DUCT SMOKE DETECTOR, FACTORY-INSTALLED IN SUPPLY AIR TUNNEL PER NFPA 72, PRE-WIRED TO VFD SAFETY CIRCUIT FOR AUTO-SHUTDOWN IN ACCORDANCE WITH 2018 IMC. COORDINATE WITH FIRE ALARM CONTRACTOR EO ENSURE COMPATIBILITY FOR MONITORING IN FIRE ALARM SYSTEM.
8. OUTDOOR UNIT COMPLYING WITH SPECIFICATION 23 74 13. PROVIDE WITH FACTORY-INSTALLED, CURBED, VALVE ENCLOSURE BUMP-OUT, 36" DEPTH, FROM COIL SECTION. ENCLOSURE SHALL HOUSE SUPPLY AND RETURN ISOLATION VALVES, CONTROL VALVE, AND AUTO AIR VENTS WITH AMPLE ACCESS SPACE. PROVIDE WITH HINGED ACCESS DOORS ON ALL
THREE SIDES. DIMENSIONED DRAWING OF THE ENCLOSURE INDICATING INCLUDED ACCESSORIES SHALL BE A MANDATORY SUBMITTAL REQUIREMENT.
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 ADDENDUM 1 09/25/2023
MBible Stamp
A. REFER TO M-001 AND M-002 FOR MECHANICAL SYMBOLS, ABBREVIATIONS,
AND GENERAL NOTES.
B. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
C. REFER TO G-SERIES LIFE SAFETY PLANS FOR LEGEND AND DETAILED
LOCATIONS OF RATED CONSTRUCTION REQUIRING ADDITIONAL MEP
PENETRATION SEALING MEASURES IN ACCORDANCE WITH THE
SPECIFICATIONS.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT HAS BEEN PERFORMED IN
ACCORDANCE WITH HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS.
9 10 11 11.1 11.2 11.7
A
B
C1
C
D
E
E.1
HAZARDOUS
STORAGE
BS03
PUMP
ROOM
BS05A
LAUNDRY
BS07B
POWER
WASH
BS05
COMPACTOR
ROOM
BS07
GREASE
INTERCEPTOR
BS07A MED GAS
STOR
MED GAS
MANIFOLDS
BS10
SOILED
LINEN
BS08
EQMT
STORAGE
BS07C
ASH SILO
BSO5C
CORRIDOR
BCS05
CORRIDOR
BCS03
(E) EF-1
EF-5
14"x12"
"ø
STAIR
BST05
EG-4
300 CFM
SD-1
240 CFM
SG-3
350 CFM
EG-5
400 CFM
SD-1
110 CFM
2290 CFM
EG-4
350 CFM
SD-1
120 CFM
EG-1
130 CFM
6" x6
"x
8" VD
VD
12"x10"14"x10"
"x
VD
EG-4
270 CFM
EG-4
270 CFM
SD-2
210 CFM
SD-2
210 CFM
"ø
CV-1
CV-2
CV-3
CV-4
CV-5
SG-1
270 CFM
8" x8
16"ø
"ø
7" ø
"ø
8"x6"
12"ø
(E) UH
VD VD
VD
VD
ELEC
BS09
VD VD
EG-3
500 CFM
12"x12"BR
12"x12"
EG-3
500 CFM
BR
SG-2
222 CFM
SG-2
222 CFM
SG-2
222 CFM
SG-2
222 CFM
SG-2
222 CFM
SG-2
222 CFM
VD
16"ø EA
U
"ø
14"x12"
"x
8" x1
2"
6"ø
8"ø
8" ø 8" ø
10"ø
6" ø
6" ø
BOD 10'-7"
BUILDING 36
BUILDING 19
EG-3
500 CFM
EG-3
500 CFM
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
T ru e N or th
BLDG 01
Drawin…
This is the start of the file's text. The full file is on GovTribe.