675-901-Expand ED BID Dwgs 2 of 2 - P.M.E.T.FA._2022-05-09.pdf

PDF 11 MB Posted

Attached to
Expand Emergency Department Minor Construction Lake Nona
Solicitation number
36C77622B0023_1
Issued by

About this file

This document provides details on a federal contract opportunity to expand the emergency department at Lake Nona VA Medical Center. The solicitation number is 36C77622B0023_1 for the project titled "Expand Emergency Department Minor Construction Lake Nona." The opportunity type is a solicitation issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The solicitation seeks construction services to expand the emergency department at the Lake Nona VA Medical Center in Orlando, Florida. Interested contractors should respond with pricing and qualifications by the specified response date. The award date listed is for September 2022, with work to be completed within one year.

View the file

Other files

File Type Posted
Expand ED at Lake Nona - RFI Responses 2022.05.20.pdf PDF
36C77622B0023 0005 - 5-20-22.pdf PDF
00 01 10 Table of Contents_R 5.20.2022.pdf PDF
08 45 23 Translucent Fiberglass Sandwich Panels_R 05.20.2022.pdf PDF
36C77622B0023 0004.pdf PDF
675-901-Expand ED BID Dwgs 1 of 2 - C.A.S.FP._2022-05-09.pdf PDF
36C77622B0023 Amendment 0003 - 5-11-22.pdf PDF
Irrigation drawing 2.pdf PDF
Irrigation drawing 1.pdf PDF
Expand ED at Lake Nona - RFI Responses 2022.05.11.pdf PDF
54MB File 675-901-Expand ED at Lake Nona - BID Drawings 2022.04.21.pdf PDF
ED Site Visit Sign - in sheet.pdf PDF
36C77622B0023 0002.pdf PDF
36C77622B0023 0001.pdf PDF
675-901 - Addendum No. 01.pdf PDF
675-901 - CIVIL DRAWING Exp ED CS-021 to CS-151.pdf PDF
675-901 - STRUCTURAL DRAWING Exp ED S-001 to S-901.pdf PDF
675-901 - Drawing AD101.pdf PDF
675-901 - Drawing AD102.pdf PDF
IFB - 36C77622B0023.pdf PDF
675-901 - FIRE PROTECTION DRAWING Expand Emergency Dept.pdf PDF
675-901 - PLUMBING DRAWINGS Expand Emergency Dept.pdf PDF
675-901 - FIRE ALARM DRAWINGS Expand Emergency Dept.pdf PDF
675-901 - CODE SHEET Expand Emergency Dept.pdf PDF
675-901 - ARCHITECTURAL DRAWINGS Expand Emergency Dept.pdf PDF
675-901 - TELECOM DRAWINGS Expand Emergency Dept.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
675-901 - COVER SHEET Expand Emergency Dept.pdf PDF
675-901 - ELECTRICAL DRAWINGS Expand Emergency Dept.pdf PDF
675-901 - UPDATED BID SPECS Expand Emergency Dept - 2022.03.15.pdf PDF
COVID-19 Safety Protocols 12-14-21.pdf PDF
675-901 - MECHANICAL DRAWINGS Expand Emergency Dept.pdf PDF
675-901 - FIRE PROTECTION 1 DRAWING Expand Emergency Dept.pdf PDF
Const Wage Orange Co - 2-25-22.pdf PDF
Contractor Safety - Environmental Form.docx DOCX document
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

32.

33.

PLUMBING GENERAL NOTES

ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH 2021 VA PLUMBING DESIGN MANUAL, 2020 7TH

EDITION FLORIDA BUILDING CODE - PLUMBING, AND VA FACILITY STANDARDS.

LOCATE VALVES IN ACCESSIBLE AREAS AND PROVIDE ACCESS PANELS WHERE NECESSARY. (12"X12"

MIN.)

COORDINATE ACTUAL LOCATIONS OF MECHANICAL FLOOR DRAINS WITH FINAL EQUIPMENT

LOCATIONS ON SHOP DRAWINGS.

VENT PIPING SHOWN IS ONLY FOR DIAGRAMMATIC PURPOSES. COORDINATE VTRS WITH HVAC AIR

INTAKES AND MAINTAIN A MINIMUM 25 FT CLEARANCE FROM AIR INTAKES.

PROVIDE BACKWATER VALVES FOR CONDENSATE PIPING CONNECTIONS TO STORM SEWER.

PROVIDE PIPE MARKER FOR ALL PIPING ABOVE THE CEILING SPACES IN ACCORDANCE WITH

SPECIFICATIONS AND FACILITY STANDARDS.

LABEL VALVES ABOVE CEILINGS AND IN CONCEALED SPACES AT CEILING TILE WITH METAL CEILING TACKS INDICATING VALVE # AND TYPE OF WATER. (i.e.; BLUE= COLD WATER, LETTERING CW

VLV1-001).

PROVIDE AND INSTALL WATER HAMMER ARRESTORS ON ALL HW AND CW SUPPLY PIPING WITH QUICK

CLOSING VALVES IN ACCORDANCE WITH PDI-WH201 STANDARDS. AIR CHAMBERS ARE NOT

ACCEPTABLE SUBSTITUTIONS.

PROVIDE THERMAL INSULATION FOR HOT WATER AND HOT WATER RETURN PIPING IN ACCORDANCE WITH THE ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION AND PER SPECIFICATIONS.

PROVIDE CLEANOUTS AT THE BASE OF EACH SANITARY STACK, ALONG HORIZONTAL RUNS SPACED AT 100'-0" INTERVALS AND AT HORIZONTAL CHANGE OF DIRECTION > THAN 45° IN ACCORDANCE WITH

FLORIDA BUILDING CODE - PLUMBING. SIZE CLEANOUTS TO MATCH THE PIPING SERVED.

FIRE CAULK AND SLEEVE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. REFER TO LIFE

SAFETY PLANS FOR RATED ASSEMBLY LOCATIONS. REFER TO ARCHITECTURAL SHEETS FOR

DETAILS AND UL ASSEMBLY NUMBERS.

REFER TO ARCHITECTURAL SHEETS FOR FIXTURE MOUNTING HEIGHTS.

COORDINATE PIPING ELEVATIONS IN SHOP DRAWINGS WITH HVAC, FIRE PROTECTION,

TELECOMMUNICATION, ELECTRICAL AND STRUCTURAL TRADES TO ENSURE PROPER SERVICE

CLEARANCES AND PENETRATIONS, PRIOR TO INSTALLATION.

SLOPE SANITARY PIPING 2-1/2" OR LESS AT 1/4" PER FOOT. SLOPE SANITARY PIPING 3" AND LARGER

AT 1/8" PER FOOT TO ENSURE MINIMUM VELOCITY OF 2 FT/S.

VALVES AND FITTINGS SHALL BE THE SAME SIZE AS THE PIPING WHERE LOCATED UNLESS

NOTED OTHERWISE.

PROVIDE ALL NECESSARY SUPPORTING DEVICES FOR FIXTURES PER MANUFACTURER INSTALLTAION

INSTRUCTIONS.

FLOOR DRAINS NOT RECEIVING CONTINUOUS DISCHARGE SHALL BE PROVIDED WITH TRAP PRIMER

CONNECTIONS. PROVIDE DEEP SEAL P-TRAPS ON ALL FLOOR DRAINS.

ROUGH-IN WASTE AND WATER SUPPLIES FOR FIXTURES AND PERFORM FINAL CONNECTIONS AS

REQUIRED PER OWNER RECOMMENDATIONS AND MANUFACTURER INSTALLATION INSTRUCTIONS.

ROUGH-IN WATER CLOSET FLUSH VALVES SO THAT THE FLUSH VALVE HANDLE IS TO THE WIDE SIDE

OF THE ROOM.

COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY GUIDELINES FOR

BUILDINGS AND FACILITIES.

DISINFECT DOMESTIC WATER PIPING BY EITHER OF TWO WAYS: FILL SYSTEM WITH 50PPM CHLORINE SOLUTION AND STAND FOR 24 HOURS OR 200PPM CHLORINE SOLUTION AND STAND FOR 3 HOURS.

ALL AUTOMATIC CONTROL PROTECTIVE OR SIGNAL DEVICES REQUIRED FOR THE OPERATION

SPECIFIED, SHALL BE PROVIDED WITH ANY CONTROL WIRING AND INSTALLED PER MANUFACTURER

INSTALLATION REQUIREMENTS.

SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT NO-HUB CAST IRON PIPE.

ALL HOT, COLD AND HOT WATER RETURN PIPE SHALL BE TYPE 'L' COPPER PIPE.

PROVIDE INDIRECT WASTE WITH AN AIR GAP MINIMUM 2 PIPE DIAMETERS OF THE DRAIN SERVED

FROM INDIVIDUAL FIXTURES, DEVICES, APPLIANCES AND APPARATUS.

DISSIMILAR PIPE CONNECTIONS SHALL BE PROVIDED WITH DIELECTRIC UNIONS.

LOWEST PORTION OF HOT WATER AND HOT WATER RECIRCULATION DISTRIBUTION BRANCH PIPING SHALL BE SLOPED BACK TO A MEANS OF DRAINING SYSTEM AND ALLOW FOR FACILITY THERMAL

FLUSHING REQUIREMENTS.

HOT WATER AND HOT WATER RECIRCULATION PIPING SHALL BE ROUTED UP TO SENSOR FAUCETS AND MIXING VALVES IN ACCORDANCE WITH SECTION 404.5 OF THE 2020 FLORIDA BUILDING CODE, ENERGY CONSERVATION.

COORDINATE PENETRATIONS THRU EXITING SLAB AND DISHING OF SLAB FOR NEW FLOOR DRAINS

WITH STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION.

PROVIDE LOCKABLE BALL VALVES ON BOTH COLD AND HOT WATER SUPPLY TO THERMOSTATIC

MIXING VALVES SERVING EMERGENCY FIXTURES (I.E. EYE WASH, EYE WASH DRENCH SHOWER).

PROVIDE LOCKABLE BALL VALVES ON ALL MEDICAL GAS PIPING. LABEL VALVES WITH THE ROOMS

SERVED

SHOP DRAWINGS SHALL BE FULLY COORDINATED PRIOR TO SUBMITTAL.

HOT WATER RECIRCULATION BRANCHES SHALL BE PROVIDED WIH BALANCING VALVES. REFER TO

THE FLOOR PLANS FOR FLOW RATES.

A

B

SIM

A

DESCRIPTIONSYMBOL

110° HOT WATER PIPINGHW

HOT WATER RETURN PIPINGHWR

STO STORM OVERFLOW (SECONDARY)

ST STORM (PRIMARY)

SANITARY PIPINGS

V VENT PIPING

GATE VALVE

PRESSURE GAUGE

THERMOMETER

CHECK VALVE

BALL VALVE

CIRCULATING PUMP

PIPE END CAP

PIPE TURNING DOWN

PIPE TURNING UP

PIPE TURNING DOWN (TEE)

NATURAL GAS PIPING

LIGHT LINEWORK INDICATES EXISTING PIPING

OR EQUIPMENT

CLEANOUTS

CW COLD WATER PIPING

PLUMBING LEGEND

SECTION SYMBOL:

A = IDENTIFYING LETTER

B = SHEET WHERE SECTION IS SHOWN

SIM =

(ONLY NOTED IF IT APPLIES)

GENERAL LEGEND

PLUMBING RISER DESIGNATION:

A = RISER IDENTIFYING SYSTEM TYPE

1 =

SYMBOL

DESCRIPTION

REVISION CLOUD AND

REVISION NUMBER

KEYED REFERENCE

NOTE OR SHEET NOTE

22-1

A TITLE SYMBOL ON SHEET WHERE SHOWN

A = IDENTIFYING NUMBER/LETTER

CD CONDENSATE PIPING

CIRCUIT SETTER VALVE

OR

PDI-"?" WATER HAMMER ARRESTER & SIZE

THERMOSTATIC MIXING VALVE

HB-? OR WHY-? HOSE BIBB / WALL HYDRANT

FLOW ARROW

P-TRAP

ROLL DOWN

PIPING TEE

POINT OF CONNECTION

NOT ALL SYMBOLS USED

NOT ALL SYMBOLS USED

G

RISER IDENTIFYING SYSTEM NUMBER

PRESSURE REGULATING VALVE

BUTTERFLY VALVE

SIMILAR

MEDICAL AIR PIPINGMA

OXYGEN PIPINGO2

MEDICAL VACUUM PIPINGMV

NITROGEN PIPINGN

NITROUS OXIDE PIPINGN2O

POINT OF DEMOLITION

PIPING ABBREVIATIONS

A/E ARCHITECT / ENGINEER

AD AREA DRAIN/ACCESS DOOR

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISH GRADE

AG AIR GAP

AP ACCESS PANEL

AS AUTOMATIC SPRINKLER

ASD ADJUSTABLE SPEED DRIVES

ASD AUTOMATIC SPRINKLER DRAIN

ASHRAE AMERICAN SOCIETY OF HEATING,

REFRIGERATION, AIR CONDITIONING

ENGINEERS

ASME AMERICAN SOCIETY OF MECHANICAL

ENGINEERS

ASPE AMERICAN SOCIETY OF PLUMBING

ENGINEERS

ASR AUTOMATIC SPRINKLER RISER

AV ACID VENT

AW ACID WASTE

BFP REDUCED PRESSURE BACKFLOW

PREVENTER

BHP BREAK HORSEPOWER

BSP BLACK STEEL PIPE

BT BATHTUB

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

C CELSIUS

CA COMPRESSED AIR

CGA COMPRESSED GAS ASSOCIATION

CFM CUBIC FEET PER MINUTE

CI CAST IRON

CO CLEANOUT

CO2 CARBON DIOXIDE

CS CLINICAL SINK

CV CONTROL VALVE

DCW DOMESTIC COLD WATER

DFU DRAINAGE FIXTURE UNITS

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER RETURN

DHWS DOMESTIC HOT WATER SUPPLY

DI DEIONIZED WATER

DN DOWN

DOE DEPARTMENT OF ENERGY

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

DWH DOMESTIC WATER HEATER

DWR DRINKING WATER RETURN

DWS DRINKING WATER SUPPLY

DWV DRAIN WASTE VENT

EL ELEVATION

EMCS ENERGY MONOSERRAT

AND CENTRAL SYSTEM

EPA ENVIROMENTAL PROTECTION

AGENCY

EPACT ENERGY POLICY ACT

ESC ESCUTCHEON

ESH EMERGENCY SHOWER

ET EXPANSION TANK

EWH ELECTRIC WATER HEATER

EWS EYE WASH STATION

EWS/SH EYE WASH/DRENCH SHOWER

E EXISTING

F FAHRENHEIT

FCO FLOOR CLEANOUT

FCW FILTERED COLD WATER

FD FLOOR DRAIN

FDC FIRE DEPARTMENT

(HOSE) CONNECTION

FM FLOW METER

FOP FUEL OIL PUMP

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FOV FUEL OIL VENT

FS FLOOR SINK

FS FLOW SWITCH

FT/S FEET PER SECOND

FU FIXTURE UNITS

GAL GALLON

GCO GRADE CLEANOUTS

GPD GALLONS PER DAY

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GPR GAS PRESSURE REGULATOR

GRS GAS REGULATOR STATION

GT GREASE TRAP

GVTR GAS VENT THROUGH ROOF

GWH GAS FIRED WATER HEATER

H&CW HOT AND COLD WATER

HB HOSE BIBB

HD HUB DRAIN

HEX HEAT EXCHANGER

HP HORSEPOWER

HS HAND SINK

HST HOT WATER STORAGE TANK

(DOMESTIC)

HWB HOT WATER BOILER

HWCP HOT WATER CIRCULATING PUMP

HWP HOT WATER PUMP

HYD HYDRANT

ID INSIDE DIAMETER

IE INVERT ELEVATION

ICW INDUSTRIAL COLD WATER

IHW INDUSTRIAL HOT WATER

INV INVERT

IPC INTERNATIONAL PLUMBING CODE

IRW IRRIGATION WATER

IW INDIRECT WASTE

IWH INSTANTANEOUS WATER HEATER

IWR INDUSTRIAL WATER RETURN

IWS INDUSTRIAL WATER SUPPLY

KW KILOWATT

KWH KILOWATT-HOUR

L/S LITER PER SECOND

LA LABORATORY AIR

LAV LAVATORY

LBS/HR POUNDS PER HOUR

LCW LABORATORY COLD WATER

LHW LABORATORY HOT WATER

LNG LIQUID NATURAL GAS

LOX LIQUID OXYGEN

LV LABORATORY VACUUM

LW LOW WATER

M METER

MA MEDICAL AIR

MAV MANUAL AIR VENT

MBH 1000 BTUH

MED MEDICAL

MER MECHANICAL EQUIPMENT

ROOM

MH MANHOLE

MOU MEMORANDUM OF

UNDERSTADING

MSB MOP SERVICE BASIN

MV MEDICAL VACUUM

N2 NITROGEN

N20 NITROUS OXIDE

NC NORMALLY CLOSED

NG NATURAL GAS

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NOM. NOMINAL

NPW NON POTABLE WATER

NTS NOT TO SCALE

O2 OXYGEN

OC ON CENTER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OR OPERATING ROOM

OVFL OVERFLOW

PA PASCAL

PD PRESSURE DROP OR DIFFERENCE

PDI PLUMBING AND DRAINAGE

INSTITUTE

PG PRESSURE GAGE

PP PLUMBING PUMP

PPM PARTS PER MILLION

PRS PRESSURE REDUCING STATION

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH

ATMOSPHERE

PSIG POUNDS PER SQUARE INCH

GAGE

PTRV PRESSURE TEMPERATURE RELIEF

VALVE

PW POTABLE WATER

RD ROOF DRAIN

RDL ROOF DRAIN LEADER

RL ROOF LEADER

RP RECIRCULATION PUMP

RO REVERSE OSMOSIS WATER

RWL RAIN WATER LEADER

SAN SANITARY SEWER

SMACNA SHEET METAL AND AIR

CONDITIONING CONTRACTORS

NATIONAL ASSOCIATION

SCFM STANDARD CUBIC FOOT/MINUTE

SCW SOFTENED COLD WATER

SDMH STORM DRAIN MANHOLE

SMH SANITARY MANHOLE

SP SUMP PUMP

SPR SPRINKLER LINE

SQFT/SF SQUARE FEET

SS STAINLESS STEEL

ST STORAGE TANK

SW STORM WATER

TCV TEMPERATURE CONTROL

VALVE

TD TEMPERATURE DIFFERENCE

TD TRENCH DRAIN

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

TMV THERMOSTATIC MIXING VALVE

TP TRAP PRIMER

TSTAT THERMOSTAT

TWR TEMPERED WATER RETURN

TWS TEMPERED WATER SUPPLY

TYP TYPICAL

U/G UNDER GROUND

V VENT

VAC VACUUM

VB VACUUM BREAKER

VCO VACUUM CLEANER OUTLET

VP VACUUM PUMP

VS VENT STACK

VSD VARIABLE SPEED DRIVE

VTR VENT THROUGH ROOF

W WASTE

WC WATER CLOSET

WCO WALL CLEANOUT

WG WATER GAGE

WH WALL HYDRANT

WH WATER HEATER

WHA WATER HAMMER ARRESTER

WL WATER LINE

WM WATER METER

WPD WATER PRESSURE DROP

WS WASTE STACK

WSFU WATER SUPPLY FIXTURE UNITS

YCO YARD CLEANOUT

YH YARD HYDRANT

ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION

MEDICAL AIR PIPING (EXISTING)MA (E)

OXYGEN PIPING (EXISTING)O2 (E)

MEDICAL VACUUM PIPING (EXISTING)MV (E)

WASTE ANESTHETIC GAS DISPOSALWAGD

SANITARY PIPING BELOW SLABS

ST STORM (PRIMARY) UNDERSLAB

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-001

PLUMBING LEGENDS, SYMBOLS,

& GENERAL NOTES

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

SHEET LIST

Sheet Number Sheet Name

P-001 PLUMBING LEGENDS, SYMBOLS, & GENERAL NOTES

PS111 PLUMBING GRAVITY OVERALL PLAN

PS121 PLUMBING GRAVITY PLAN - LEVEL 1 ROOF

PP111 PLUMBING PRESSURE OVERALL PLAN

PP121 PLUMBING PRESSURE PLAN - LEVEL 1 INTERSTITIAL

PG111 PLUMBING MED GAS OVERALL PLAN

PG121 PLUMBING MED GAS PLAN - LEVEL 1 INTERSTITIAL

P-401 PLUMBING ENLARGED PLANS

P-501 PLUMBING DETAILS

P-601 PLUMBING GRAVITY ISOMETRICS

P-602 PLUMBING PRESSURE ISOMETRICS

P-603 PLUMBING MED GAS ISOMETRICS

P-801 PLUMBING SCHEDULES

Revisions Date

4.2

3.2 2.2

A.2

1.2

A.6

34.5

34.2

4.8

3.8 2.8 1.4

34.4

35.45.0

3" V UP TO

4" VTR

4" WCO

4" S

8" S (E)

15" ST (E)

3" S

4" FD-C

P-516

P-420

P-201

P-103

P-420

P-103

P-103

Check-In

109 Check-In

Triage

Nurse First/ Reception

Front End Triage

Triage

Vestibule

Waiting

Electric

Women's Toilet

Men's Toilet

Triage

4" ST

6" STO

6" ST

6" ST

6" STO

6" STO DN TO

DOWNSPOUT. REFER

TO DETAIL 6/P-501 6" ST DN

REFER TO CIVIL PLANS FOR

CONTINUATION. COORDINATE

INVERT AND OFFSET PIPE AFTER

BACKWATER VALVE AS NEEDED.

4" ST & STO

UP TO RD

105 GPM

6" ST & STO

UP TO RD

159 GPM

15" ST (E)

4" S (E)

4" S (E)

P-420

P-420

FCO

4" 2-WAY ECO

4" FD-C

P-516

P-516

P-516

2" WCO

2" V UP TO

3" VTR

2" S2" S

4" S

4" S

4" S

4" S

2" S

2" S

4" S

4" S

2" S

2" S

2" S

4" S

4" S

4" S 2" V

2" V

3" V

3" V

2" V

2" V

INV. ELEV.

-3.50'

REFER TO CIVIL PLANS

FOR CONTINUATION

1 1/2" V

1 1/2" V

1 1/2" V

264 GPM

264 GPM

2" V

2" ST

2" ST

2" ST

PROVIDE BACKWATER VALVE

PROVIDE BACKWATER VALVE

REFER TO CIVIL PLANS FOR

CONTINUATION. COORDINATE

INVERT AND OFFSET PIPE AFTER

BACKWATER VALVE AS NEEDED.

2" ST STUBBED UP THROUGH CONCRETE

PAD FOR CONNECTION TO GUTTER

DOWNSPOUT. COORDINATE EXACT

LOCATION WITH ARCHITECTURAL PLANS

2" S

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

2:

P M

PS111

PLUMBING GRAVITY OVERALL

PLAN

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

DRAWING NOTES:

1. REFER TO P-400 FOR ENLARGED PLANS.

2. SLOPE ALL VENT PIPING BACK TO SANITARY MAIN.

0 2' 4' 8' 12'

1/4" = 1'-0"

N

1/4" = 1'-0"PS111

1 PLUMBING - OVERALL GRAVITY PLAN EXPANSION

CODED NOTES:

2" SAN DN, 1 1/2" V UP. 1 1/2" SAN TO SINK/LAV

4" SAN DN, 2" V UP. 4" SAN TO WC

3" SAN DN, 2" V UP. 3" SAN TO UR

4" SAN DN, 2" V UP

A.2

1.2

34.5

34.2

3.8 2.8 1.4

34.4

35.4

4" RD

2241.5 SQFT

105 GPM

4" VTR

3" VTR

6" RD

3397.0 SQFT

159 GPM

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

2:

P M

PS121

PLUMBING GRAVITY PLAN -

LEVEL 1 ROOF

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

0 2' 4' 8' 12'

1/4" = 1'-0"

N

1/4" = 1'-0"PS121

1 PLUMBING - EXPANSION ROOF GRAVITY PLAN EXPANSION

6.2 5.2 4.2

C.2

A.2

D.2

B.2

1.2

C

B

C.6

A.6

34.5 34.2

5.8 4.8

3.8 2.8 1.4

3435 34.4

A.01

35.4

D.3

5.0

J.14

P-516

3/4" HWR

3/4" HWR UP

2" CW UP

1 1/4" HW UP

3/4" HW

3/4" HWR

2" CW

1/2" CW

3/4" HW

P-401

P-401

1 1/2" CW

3/4" HWR

3/4" HW

P-516

P-516

3/4" CW

3/4" HWR

3/4" HW

2 5

2" CW 1 1/4" HW

3/4" HWR

1/2" HWR

3/4" HWR

1/2" HWR

P-516

Shower

1A702b

Sterile Supply Room

1A701 Seclusion Room

1A703

Exam/ Treatment

1A705 Exam/ Treatment

1A707 Exam/ Treatment

1A711

Exam/ Treatment

1A715

Exam/ Treatment

1A109d

Exam/ Treatment

1A109b

Exam/ Treatment

1A109a

Patient Tlt

1A704

Patient Tlt

1A105

Exam/ Treatment

1A109c

Patient Tlt

1A714

Patient Tlt

1A115

Elec

1A702d

Staff Tlt

1A608

Life Support Unit

1A112

Meds

1A409

Bathroom

1A607a

Ent Exam/ Treatment

1A118

Physician

1F505

Staff Lockers

1A607

Gyn Exam/ Treatment

1A122

Comm

1A702c

Exam/ Treatment

1A101

Gyn Exam/ Treatment

1A120

Vestibule

1A702

Operations

1B303a

Holding

1B303b

Vestibule

1B303

Elec

1F802

Central Workstation

1F716b

Satallite Workstation

1F716c

Fire Command

1B505

Armory Workrm

1B303c

Decon

1A702a Exam/ Treatment

1A709

Exam/ Treatment

1A933

Men's Toilet

Corridor

1AC01

Corridor

1AC07

Corridor

C02

Triage

Front End Triage

Check-In

110 Electric

Check-In

Nurse First/ Reception

Waiting

Triage

Triage

Women's Toilet

Vestibule

Triage Sub-Waiting

105A

Roof Access exterior

EXT

Isolation

1A717

Isolation

1A721

Ante Rm

1A719

Office

1A801

Triage

1A718

Triage

1B204

Triage

1B202

Physician

1F507

Results Waiting

1A124

Procedure Check In

1B205

Procedure Check In

1B203

Phone

1A501

Waiting

1A121

Mas Workrm

1B201

Comm

1B201b

Ed Tlt Male

1A502

Ed Tlt Female

1A504

Nurse First

1A121a Elec

1B201a

Triage

1A119 Office

1A803 exterior

EXT

1/2" CW

3/4" HWR

3/4" HWR

3/4" HW

1/2" CW

PROVIDE DROP FITTING

ISOLATION VALVE (TYP)

2 5

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

PP111

PLUMBING PRESSURE OVERALL

PLAN

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

DRAWING NOTES:

1. REFER TO P-400 SERIES FOR ENLARGED PLANS.

CODED NOTES:

HWR BALANCING VALVE SET AT 2.75 GPM.

3/4" HW TO BECOME 3/4" HWR AFTER 1/2" TAP TO LAVATORY, THEN ROUTED UP. 1/2" HW TO TMV-1.

LOCK BALL VALVE IN THE CLOSED POSITION. PIPING CAPPED FOR FUTURE RENOVATION.

1/2" CW FROM TRAP PRIMER. REFER TO P-401 FOR CONTINUATION.

1/2" CW ROUTED DOWN TO SINK. 1/2" CW TO TMV-1 AND TO SINK.

HWR BALANCING VALVE SET AT 3.0 GPM.

0 4' 8' 16' 24'

1/8" = 1'-0"

N

1/8" = 1'-0"PP111

1 PLUMBING - OVERALL PRESSURE PLAN EXPANSION

U

3.2 2.2

C.2

A.2

D.2

B.2

1.2

C

B

C.6

A.6

34.5 34.2

5.8 4.8

3.8 2.8 1.4

3435 34.4

A.01

35.4

D.3

5.0

J.14

6" CW (E)

2" HWR (E)

4" HW (E)

3" HW (E)

1" HWR (E)

4" CW (E)

4" CW (E)

1 1/4" HWR (E)

3" HW (E)

3" CW (E)

2" HW (E)

2" HW (E)

2 1/2" CW (E)

2" HW (E)

2 1/2" CW (E)

1" HW (E)

2" CW (E)

2" CW (E)

1" HW (E)

3/4" HWR DN

2" CW

1 1/4" HW

1 1/4" HW &

2" CW DN

ISOLATION VALVE (TYP)

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

PP121

PLUMBING PRESSURE PLAN -

LEVEL 1 INTERSTITIAL

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

DRAWING NOTES:

1. FLOOR PLAN IS SHOWN FOR REFERENCE ONLY.

0 4' 8' 16' 24'

1/8" = 1'-0"

N

1/8" = 1'-0"PP121

1 PLUMBING - LEVEL 1 INTERSTITIAL PRESSURE PLAN EXPANSION

CODED NOTES:

CONNECT NEW 3/4" HWR TO (E)1 1/4" HWR IN THE INTERSTITIAL SPACE. COORDINATE SHUTDOWN

WITH OWNER PRIOR TO CONSTRUCTION.

CONNECT NEW 2" CW & 1 1/4" HW TO (E)2 1/2" CW AND 2" HW IN THE INTERSTITIAL SPACE.

COORDINATE SHUTDOWN WITH OWNER PRIOR TO CONSTRUCTION.

1.2

A.6

34.5 34.23.8 2.8 1.4

35 34.4

35.4

ZVB-1

1/2" MA

Check-In

Check-In

Triage

Nurse First/ Reception

Front End Triage

Triage

Vestibule

Waiting

Electric

Women's Toilet

Men's Toilet

Triage

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

3/4" O2

1/2" O2

1/2" O2

1" MV

3/4" MV

3/4" MV

3/4" MA

1/2" MA

1/2" MA

1/2" O2

3/4" MV

MGO-1

MGO-2

MGO-3

1/2" O2

1/2" MA

3/4" MV

3/4" MV

1/2" MA

1/2" O2

(TYP ALL

ROOMS)

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

PG111

PLUMBING MED GAS OVERALL

PLAN

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

CODED NOTES:

1/2" O2, 1/2" MA, 3/4" MV DN TO OUTLETS

3/4" O2, 3/4" MA, 1 1/2" MV UP. 3/4" O2, 3/4" MA, 1" MV TO ZVB

PRESSURE SWITCH. WIRE BACK TO LOCAL ALARM

LOCAL MED GAS ZONE ALARM PANEL. WIRE BACK TO MASTER ALARM PANEL

0 2' 4' 8' 12'

1/4" = 1'-0"

N

1/4" = 1'-0"PG111

1 PLUMBING - OVERALL MED GAS PLAN EXPANSION

U

3.2 2.2

C.2

A.2

D.2

B.2

1.2

C

B

C.6

A.6

34.5 34.2

5.8 4.8

3.8 2.8 1.4

3435 34.4

A.01

35.4

D.3

5.0

J.14

4" MV(E)

1 1/4" MA(E)

2" O2(E)

1 1/2" MV

3/4" MA

3/4" O2

1 1/2" MV

3/4" MA

3/4" O2

Shower

1A702b Sterile Supply Room

1A701 Seclusion Room

1A703

Exam/ Treatment

1A705 Exam/ Treatment

1A707 Exam/ Treatment

1A711

Exam/ Treatment

1A715

Exam/ Treatment

1A109d

Exam/ Treatment

1A109b

Exam/ Treatment

1A109a

Patient Tlt

1A704

Patient Tlt

1A105

Exam/ Treatment

1A109c

Patient Tlt

1A714

Patient Tlt

1A115

Elec

1A702d

Staff Tlt

1A608

Life Support Unit

1A112

Meds

1A409

Bathroom

1A607a

Ent Exam/ Treatment

1A118

Physician

1F505

Staff Lockers

1A607

Gyn Exam/ Treatment

1A122

Comm

1A702c

Exam/ Treatment

1A101

Gyn Exam/ Treatment

1A120

Vestibule

1A702

Operations

1B303a

Holding

1B303b

Vestibule

1B303

Elevator

1BE01

Elevator

1BE02

Elec

1F802

Central Workstation

1F716b

Satallite Workstation

1F716c

Fire Command

1B505

Armory Workrm

1B303c

Decon

1A702a Exam/ Treatment

1A709

Exam/ Treatment

1A933

Men's Toilet

Corridor

1AC01

Corridor

1AC07

Corridor

C02

Triage

Front End Triage

Check-In

110 Electric

Check-In

Nurse First/ Reception

Waiting

Triage

Triage

Women's Toilet

Vestibule

Triage Sub-Waiting

105A

Roof Access exterior

EXT

Isolation

1A717

Isolation

1A721

Ante Rm

1A719

Office

1A801

Triage

1A718

Triage

1B204

Triage

1B202

Physician

1F507

Results Waiting

1A124

Procedure Check In

1B205

Procedure Check In

1B203

Phone

1A501

Waiting

1A121

Mas Workrm

1B201

Comm

1B201b

Ed Tlt Male

1A502

Ed Tlt Female

1A504

Nurse First

1A121a Elec

1B201a

Triage

1A119 Office

1A803 exterior

EXT

3/4" O2

1 1/2" MV

3/4" MA

ISOLATION

VALVES (TYP)

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

PG121

PLUMBING MED GAS PLAN -

LEVEL 1 INTERSTITIAL

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

DRAWING NOTES:

1. FLOOR PLAN IS SHOWN FOR REFERENCE ONLY.

2. COORDINATE MED GAS SHUT-DOWN WITH OWNER PRIOR TO ANY CONSTRUCTION.

CODED NOTES:

3/4" O2, 3/4" MA, 1 1/2" MV DN

LOCKABLE VALVES IN THE OPEN POSITION

(E)1/2" O2, 1/2" MA, 1 1/2" MV DN

CAP PIPING FOR FUTURE CONNECTION AND LOCKABLE BALL VALVES IN THE CLOSED POSITION

0 4' 8' 16' 24'

1/8" = 1'-0"

N

1/8" = 1'-0"PG121

1 PLUMBING - LEVEL 1 INTERSTITIAL MED GAS PLAN EXPANSION

Women's Toilet

P-420

P-420

P-103

P-103

1 1/4" CW

1 1/4" CW

1 1/2" CW

3/4" HWR

3/4" HW

1/2" CW

1/2" CW

FD-C

1/2" CW

A.2

3.8

Men's Toilet

Roof Access

P-103

P-201

P-420

1 1/2" CW

3/4" HWR

3/4" HW

P-420

TP-1 7

FD-C

1/2" CW U/G

1 1/4" CW

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-401

PLUMBING ENLARGED PLANS EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

1/2" = 1'-0"1 PLUMBING ENLARGED PRESSURE PLAN EXPANSION -RM 106

1/2" = 1'-0"2 PLUMBING ENLARGED PRESSURE PLAN EXPANSION - RM 100 & 107

0 1' 2' 4' 6'

1/2" = 1'-0"

CODED NOTES:

REFER TO PP111 FOR CONTINUATION.

3/4" HW DOWN TO RUN IN WALL HORIZONTALLY. TAP OFF WITH 1/2" HW TO EACH LAVATORY. 1/2" HW

TO TMV-1.

3/4" HW TO BECOME 3/4" HWR AFTER 1/2" TAP TO LAVATORY, THEN ROUTED UP. 1/2" HW TO TMV-1.

3/4" CW ROUTED DOWN TO URINAL.

1-1/4" CW ROUTED DOWN TO WATER CLOSET.

1/2" CW ROUTED DOWN TO LAVATORY. 1/2" CW TO TMV-1 AND TO LAVATORY.

3/4" CW ROUTED DOWN TO TRAP PRIMER.

1/2" CW FROM TRAP PRIMER, DOWN BELOW GRADE, AND ROUTED TO FLOOR DRAIN.

N

4" x 3" x 4"

WELD TO 5"

EXTRA HEAVY RISER

CLAMP-BOLT TO 4"L

LEG AGAINST WALL

PIPE

"Ø BOLTS

1'-0"

PIPE HANGER (SEE

SPECIFICATIONS 22 05 11)

GALVANIZED SHEETMETAL

PIPE SADDLE W/FLARED ENDS

INSULATED PIPE

PIPE HANGER (SEE

SPECIFICATIONS 22 05 11)

TEST TEE

THREADED

CLEANOUT PLUG

ACCESS COVER AND FRAME

FINISHED WALL SURFACE

2" MINIMUM AIR

GAP (SEE NOTE)

FLOOR DRAIN (FD-B) WITH

INTERNAL BACKWATER VALVE

DRAIN LINE

TO "P" TRAP

FINISHED FLOOR

REMOVABLE GRATE

SUPPORT PIPING

EVERY 4'-0"

INDIRECT WASTE

LINE

NOTE:

THE AIR GAP BETWEEN THE INDIRECT WASTE PIPEAND THE FLOOD LEVEL RIM OF THE WASTE RECEPTOR SHALL BE A

MINIMUM OF TWICE THE EFFECTIVEOPENING OF THE INDIRECT WASTE PIPE.

TWO WAY CLEAR CUT

FITTING

12" DIAMTER x 4" THICK

CONCRETE COLLAR

IN AREAS W/NO SLAB

SCORIATED CLEANOUT COVER

(ZURN - Z-1406)

CLEANOUT PLUG

PAVEMENTGRADE

SECTION

CAST IRON CLEANOUT COLLAR

W/HEAVY DUTY COVER

PAVEMENT

18" SQ x 4" DEEP

CONC. PAD

CLEAN-OUT COVER

IN VEHICULAR

TRAFFIC AREAS

SHALL BE DUCTILE IRON

TWO-WAY

C.O. FTG.

RECESSED ALARM PANEL (AP) WITH

CONTINUOUS DIGITAL DISPLAY OF ALL

MEDICAL GASES AND VACUUM

PROVIDE ZONE

IDENTIFICATION SIGN

120V/1Ø POWER SUPPLY BY ELECTRICAL

CONTRACTOR,COORDINATE EXACT

LOCATION BEFORE CONSTRUCTION

SIGNAL WIRING IN

CONDUIT FROM

PRESSURE SWITCHES

CONDUIT WITH

SIGNAL WIRING FROM

PRESSURE SWITCHES

TO ALARM PANEL

PROVIDE PERMANENT IDENTIFICATION

FOR LOCATION OF SWITCHES LOCATED IN

CEILING SPACE

PROVIDE SUPPORT FOR

PRESSURE/VACUUM SWITCHES SEPARATE

FROM PIPE SUPPORTS

MEDICAL GAS ZONE PIPING DOWN IN

WALL,SEE PLANS FOR EXACT SIZE AND

LOCATION

RECESSED MEDICAL GAS ZONE VALVE BOX (MGV) WITH

SHUT-OFF VALVES, PRESSURE/VACUUM GAUGES AND

REMOVABLE WINDOW WITH PULL RING

CONNECT TO CAPPED PIPE

EXTENSION (TYPICAL)

CONDUIT WITH SIGNAL WIRING FROM

PRESSURE/VACUUM SWITCH TO AREA ALARM PANEL

(AP) BY ELECTRICAL CONTRACTOR, COORDINATE

EXACT LOCATION BEFORE CONSTRUCTION.

PRESSURE/VACUUM

SWITCH (TYPICAL)

PROVIDE UNIVERSAL QUICK-

CONNECT FITTING FOR IN-LINE

PRESSURE/ VACUUM SWITCH

(TYPICAL)

ZURN #Z-199 DOWNSPOUT NOZZLE

STORM DRAIN PIPING, SEE FLOOR

PLANS FOR SIZE AND LOCATIONS

STORAGE ROOM WALL

GARAGE FINISHED FLOOR

18"-36"MAX

SPLASH BLOCK

4' -0

FLOOR DRAIN

P-TRAP

4 TO 30

FLOOR DRAINS

BALL VALVE

3/4" COLD WATER

FINISH FLOOR

1/2" TYPE "K" SOFT SEAMLESS COPPER

WITH NO JOINTS BELOW FLOOR SLAB.

SLOPE AT 1/8" PER FOOT MINIMUM TO

FLOOR DRAIN CONNECTION.

120/1/60 ELECTRICAL

CONNECTION

ELECTRONIC TRAP PRIMING MANIFOLD SUITABLE FOR 4 TO 30

FLOOR DRAINS. COMPLETE WITH CIRCUIT BREAKER, TIMER,

BALL VALVE, SOLENOID VALVE & VACUUM BREAKER

COMPLETLY MOUNTED IN STEEL CABINET ENCLOSURE.

(PRECISION PLUMBING PRODUCTS PT-4 THRU PT-30)

SOLENOID VALVE

24-HOUR TIME CLOCK

WITH TEST AND

OVERRIDE BUTTONS.

VACUUM BREAKER

GALVANIZED STEEL

CABINET

FINISHED FLOOR

FOR FIXTURE HEIGHT

SEE ARCHITECTURAL

DRAWINGS

1" [25mm] STOP

[56mm] 2 1/4"

[69mm] 2 3/4"

[119mm] 4 3/4"

FR

O

M F

LO

O

R

0m m

[8 m m

/8

[4 m m

[2 m m

1/ 2"

[6 3m m

1/

2"

[4 m m

NOTE:

FURNISH 24 VOLT TRANSFORMER

C/L OF FIXTURE

FINISHED WALL

MANUAL OVER-RIDE

BUTTON

SENSOR

ELECTRICAL BOXES

OR CATCH BASIN

TO STORM DRAIN

CAST IRON BACKWATER VALVE

W/PVC FLAPPER AND O-RING

SEAL EQUAL TO ZURN-Z-1090

GRADE

10" DIAMETER CAST IRON COVER

MARKED 'BACKWATER VALVE',

EQUAL TO BROOKS 3-RT SERIES

PRECAST CONCRETE BODY

PROVIDE EXTENSIONS AS

REQUIRED

UNDERGROUND

CONDESATE DRAIN

PIPING, SEE PLAN FOR SIZE

FAUCET

LAVATORY

SUPPLY ANGLE

STOP (TYP)

NOTES:

1. ALL PIPING BETWEEN WATER HEATER AND

FAUCET SHALL BE A MINIMUM OF 1/2".

2. IF MOUNTED UNDER ADA LAVATORY,

PROVIDE INSULATION ON H/C LINES.

TEMPERED WATER

SET 105°F MAX

1/2" CW SUPPLY

1/2" HW SUPPLY

3/4" HW SUPPLY IN WALL

1/2" CW SUPPLY

IN WALL

AFTER CONNECTION TO

SINK, 3/4" HW TURNS TO

3/4" HWR

3/4" HWR SUPPLY IN WALL

TMV-1, REFER

TO SCHEDULE

FAUCET

LAVATORY

SUPPLY ANGLE

STOP (TYP)

NOTES:

1. ALL PIPING BETWEEN WATER HEATER AND

FAUCET SHALL BE A MINIMUM OF 1/2".

2. IF MOUNTED UNDER ADA LAVATORY,

PROVIDE INSULATION ON H/C LINES.

TMV-1, REFER

TO SCHEDULE

TEMPERED WATER

SET 105°F MAX

1/2" CW SUPPLY

1/2" HW SUPPLY

3/4" HW SUPPLY IN WALL

3/4" CW SUPPLY

IN WALL

AFTER LAST

CONNECTION TO LAV, 3/4"

HW TURNS TO 3/4" HWR

3/4" HWR SUPPLY IN WALL

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-501

PLUMBING DETAILS EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

N.T.S.

PIPE ANCHOR TO VERTICAL DETAIL1

N.T.S.

INSULATED PIPE HANGER3

N.T.S.

WALL CLEANOUT2

N.T.S.

CONDENSATE DRAIN - INSULATED4

N.T.S.

EXTERIOR CLEAN OUT (TWO WAY) DETAIL5

N.T.S.

MEDICAL GAS ZONE VALVE / ALARM PANEL DETAIL7

N.T.S.

OVERFLOW NOZZLE DETAIL6N.T.S.

ELECTRONIC TRAP PRIMER9

N.T.S.

WATER CLOSET - SENSOR OPERATED DETAIL8

N.T.S.

BACKWATER VALVE10

N.T.S.

TMV UNDER SINK11

12" = 1'-0"12 TMV UNDER MULTIPLE LAVS

8" S (E)

4" S

4" S

4" S

3" S

WCO

WCO

2-WAY ECO

FCO

P-103 P-103

P-103

P-201

P-420 P-420

P-420 P-420

6" RD

159 GPM

4" RD

105 GPM

VTR

VTR

FD-C

FD-C

4" S

4" S

2" S

2" V2" V1 1/2" V

1 1/2" V1 1/2" V

2" V

2" V

2" S 2" S

2" S 2" S

4" S

4" S

4" S

2" S

2" S 2" S

2" S

STO DOWNSPOUT NOZZLE

TO SPLASH BLOCK

6" STO

6" STO

6" STO

4" ST

6" ST

6" ST

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

2" S

2" V 2" V

2" V

1 1/2" V 1 1/2" V

2" V

3" V

1 1/2" V

264 GPM

264 GPM

2" V

P-516 P-516

P-516

P-516

8" S (E)

BACKWATER VALVE

BACKWATER VALVE

2" ST 2" ST

2" ST

2" ST STUBBED UP THROUGH CONCRETE

PAD FOR CONNECTION TO GUTTER

DOWNSPOUT. COORDINATE EXACT

LOCATION WITH ARCHITECTURAL PLANS

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-601

PLUMBING GRAVITY

ISOMETRICS

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD AJZKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

N.T.S.

PLUMBING GRAVITY RISER DIAGRAM1

DRAWING NOTES:

1. FOR REFERENCE ONLY. REFER TO FLOOR PLANS FOR MORE INFORMATION.

2. SLOPE ALL VENT PIPING BACK TO SANITARY MAIN.

6" CW (E)

2" HWR (E)

4" HW (E)

3" HW (E)

1" HWR (E)

4" CW (E)

4" CW (E)

1 1/4" HWR (E)

3" HW (E)

3/4" HWR

3/4" HWR

3/4" HWR

3/4" HWR

3" CW (E)

2" HW (E)

2" HW (E)

2 1/2" CW (E)

2 1/2" CW (E)

2" HW (E)

2" CW

1 1/4" HW

3/4" CW

3/4" HW

3/4" HWR

1 1/2" CW

1 1/2" CW

3/4" HW

3/4" HW

TP-1

2" CW

3/4" HW

P-103

P-103

P-103

P-201

BALANCING VALVE

BALANCING VALVE

BALANCING VALVE

BALANCING VALVE

CAP PIPING FOR FUTURE

CONNECTION AND LOCK

BALL VALVES IN THE

CLOSED POSITION

CAP PIPING FOR FUTURE

CONNECTION AND LOCK

BALL VALVES IN THE

CLOSED POSITION

CAP PIPING FOR FUTURE

CONNECTION AND LOCK

BALL VALVES IN THE

CLOSED POSITION

CAP PIPING FOR FUTURE

CONNECTION AND LOCK

BALL VALVES IN THE

CLOSED POSITION

(2) P-420

P-420

P-420

P-516

P-516

P-516

P-516

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-602

PLUMBING PRESSURE

ISOMETRICS

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD AJZKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

DRAWING NOTES:

1. FOR REFERENCE ONLY. REFER TO FLOOR PLANS FOR MORE INFORMATION

N.T.S.

PLUMBING PRESSURE RISER DIAGRAM1

CODED NOTES:

PROVIDE TMV-1 UNDER SINK/LAV. 1/2" CW & HW TO TMV. 1/2" TEMPERED WATER & 1/2" CW TO

FIXTURE.

PRESSURE SWITCHES

CAP PIPING FOR FUTURE

CONNECTION AND LOCK

BALL VALVES IN THE

CLOSED POSITION

LOCK BALL VALVES IN

THE OPEN POSITION

ZVB-1

LOCAL ALARM

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

MGO-1

MGO-2

MGO-3

1/2" O2

1/2" MA

3/4" MV

1/2" O2

1/2" MA

3/4" MV

1/2" O2

1/2" MA

3/4" MV

3/4" O2

3/4" MA

1" MV

3/4" MV

1/2" MA

1/2" O2

(TYP ALL ROOMS)

1 1/2" MV

3/4" MA

3/4" O2

3/4" O2

3/4" MA

1 1/2" MV

3/4" O2

3/4" MA

1 1/2" MV

1 1/2" MV(E)

3/4" MA(E)

3/4" O2(E)

1 1/2" MV(E)

1/2" MA(E)

1/2" O2(E)

1 1/2" MV(E)

3/4" MA(E)

3/4" O2(E)

4" MV(E)

1 1/4" MA(E)

2" O2(E)

1 1/2" O2(E)

1 1/4" MA(E)

3" MV(E)

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-603

PLUMBING MED GAS

ISOMETRICS

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD AJZKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

DRAWING NOTES:

1. FOR REFERENCE ONLY. REFER TO FLOOR PLANS FOR MORE INFORMATION

N.T.S.

PLUMBING MED GAS RISER DIAGRAM1

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

:0

1:

P M

P-801

PLUMBING SCHEDULES EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

PLUMBING MEDICAL GAS OUTLET

MARK

BASIS OF DESIGN

MANUFACTURER

BASIS OF DESIGN MODEL

NO. DESCRIPTION MOUNTING SERVICE

MGO-1 AMIC0 O-DISWAL-U-OXY MEDICAL GAS OUTLET WALL MEDICAL OXYGEN

MGO-2 AMIC0 O-DISWAL-U-AIR MEDICAL GAS OUTLET WALL MEDICAL AIR

MGO-3 AMIC0 O-DISWAL-U-VAC MEDICAL GAS OUTLET WALL MEDICAL VACUUM

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE WASTE PIPE (INCHES)

VENT PIPE

(INCHES)

COLD WATER

(INCHES)

HOT WATER

(INCHES)

WASTE FIXTURE

UNITS

WATER FIXTURE

UNITS

WRIST BLADE

HANDLES

ELECTRIC

SENSOR

P-103 WATER CLOSET 4 2 1-1/4 - 4 10 - YES

P-201 URINAL 2 1-1/2 3/4 - 2 3 - YES

P-420 LAVATORY 1-1/2 1-1/2 1/2 1/2 1 2 NO YES

P-516 SINK 1-1/2 1-1/2 1/2 1/2 3 2 YES NO

FD-C FLOOR DRAIN REFER TO FLOOR PLAN - - - 2 - - -

PLUMBING MEDICAL GAS VALVE BOX

MARK

BASIS OF DESIGN

MANUFACTURER

BASIS OF DESIGN

MODEL NO. DESCRIPTION MOUNTING SERVICES LOCATION

ZVB-1 AMICO AVU-2O2A3V ZONE VALVE BOX WALL MA, O2, & MV TRIAGE

ELECTRONIC TRAP PRIMER SCHEDULE

MARK BASIS OF DESIGN MANUFACTURER

BASIS OF DESIGN

MODEL NUMBER CW INLET CW OUTLET SIZE

MAX DRAINS

SERVED DIMENSIONS (W" x H" x D") V/PH/HZ

TP-1 PRECISION PLUMBING PRODUCTS PT-4 3/4" 1/2" 4 14" x 16" x 3-3/8" 120/1/60

NOTES:

1. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

NOTES:

1. REFER TO SPECIFICATIONS FOR MORE INFORMATION.

2. PROVIDE WITH INTEDRAL DISCONNECT.

THERMOSTATIC MIXING VALVE SCHEDULE

MARK

BASIS OF DESIGN

MANUFACTURER

BASIS OF DESIGN

MODEL NO. OUTLET/TEMPERATURE INLET/OUTLET SIZE MIN. FLOW RATE LOCATION

TMV-1 WATTS LFUSG-B 105°F 1/2" / 1/2" 0.25 GPM SINKS/LAVS

NOTES:

1. THERMOSTATIC MIXING VALVE SHALL BE PIPED PER MANUFACTURER RECOMMENDATIONS.

2. PROVIDE WITH INLET AND OUTLET SHUT-OFF VALVES.

DUCTWORK SYMBOLS

SYMBOL DESCRIPTION

HVAC ABBREVIATIONS

ABBR. DESCRIPTION ABBR. DESCRIPTION

A/E ARCHITECT / ENGINEER

AF AFTER FILTER

AFF ABOVE FINISHED FLOOR

AFMD AIR FLOW MEASURING DEVICE

AHU AIR-HANDLING UNIT

AMP AMPERAGE

APD AIR PRESSURE DROP

ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE

AS AIR SEPARATOR

ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS

B BOILER

BDD BACKDRAFT DAMPER

BFP BACKFLOW PREVENTER

BHP BRAKE HORSEPOWER

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

CC COOLING COIL

CD CONDENSATE

CFM CUBIC FEET PER MINUTE

CHW CHILLER WATER

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CO CLEANOUT

COP COEFFICIENT OF PERFORMANCE

CV CONSTANT VOLUME

D DAMPER - AUTOMATIC

DB DECIBELS

DB DRY-BULB TEMPERATURE

DDC DIRECT DIGITAL CONTROLS

DEG DEGREE

DN DOWN

LAT LEAVING AIR TEMPERATURE

LBS/HR POUNDS PER HOUR

LF LINEAR FOOT (FEET)

LPR LOW PRESSURE RETURN (STEAM CONDENSATE)

LPRC LOW PRESSURE STEAM RETURN (CLEAN)

LVG LEAVING

LWT LEAVING WATER TEMPERATURE

MA MIXED AIR

MAT MIXED AIR TEMPERATURE

MBH 1000 BTUH

MCA MINIMUM BRANCH CIRCUIT AMPACITY

MERV MINIMUM EFFICIENCY REPORTING VALUE

MIN MINIMUM

MPR MEDIUM PRESSURE RETURN (STEAM CONDENSATE)

MPS MEDIUM PRESSURE STEAM

MVD MANUAL VOLUME DAMPER

NC NOISE CRITERIA

NC NORMALLY CLOSED

NO NORMALLY OPEN

NPLV NON-STANDARD PART LOAD VALUE

NPSH NET POSITIVE SUCTION HEAD

NTS NOT TO SCALE

OA OUTSIDE AIR

P PUMP

PD PRESSURE DROP

PF PRE-FILTER

PHC PREHEAT COIL

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH – ABSOLUTE

PSIG POUNDS PER SQUARE INCH – GAGE

RA RETURN AIR

RH RELATIVE HUMIDITY

LIMIT OF DEMOLITION

DN

DN

UP

UP

SUPPLY DUCT (UP &

DOWN)

EXHAUST DUCT (UP &

DOWN)

ROUND AND SQUARE 4-WAY

CEILING DIFFUSERS

SUPPLY TOP REGISTER OR GRILLE

(WALL TYPE)

EXHAUST OR RETURN CEILING

REGISTER OR GRILLE

EXHAUST OR RETURN BOTTOM REGISTER

OR GRILLE (WALL TYPE)

EXHAUST OR RETURN REGISTER OR TOP

GRILLE (WALL TYPE)

VANED ELBOW & AIR SPLIT TYPE DUCT

TAKE-OFF

CONNECT NEW DUCT TO EXISTING

DUCT

DNUP

RETURN DUCT (UP &

DOWN)

SQUARE 3-WAY CEILING

DIFFUSERS

SQUARE 2-WAY CEILING

DIFFUSERS

SQUARE 1-WAY CEILING

DIFFUSERS

FC

10x8

FLEXIBLE CONNECTION,

EQUIPMENT, VIBRATION, OR SEISMIC

VANED ELBOW (SHORT RADIUS)

STANDARD RADIUS ELBOW (LONG

RADIUS)

NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)

EXISTING DUCT TO

REMAIN

FIRE DAMPER

FD

VD

FLEXIBLE DUCTWORK

(INSULATED)

MANUAL VOLUME DAMPER

EXISTING DUCT TO BE

REMOVED

SUPPLY

RETURN45°

STANDARD BRANCH SUPPLY

OR RETURN, NO SPLITTER(45° TAP)

45°

CONTROLS SYMBOLS

SMOKE DAMPER

SD

T ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT

AIR TERMINAL SYMBOLS

TERMINAL UNIT WITH REHEAT

COIL

DRAWING SYMBOLS

BASIC MATERIALS

EXISTING TO BE REMOVED (HEAVY, DASHED LINE)

EXISTING TO REMAIN (THIN, HALFTONED LINE)

NEW (HEAVY, SOLID LINE)

2-AHU-3-1

26-TU-I-I

VIEW NUMBER

DRAWING NUMBER WHERE SHOWN

SECTION LETTER

TYPICAL UNIT NUMBER; AHU NO. 1, LOCATED ON LEVEL 3, LOCATED IN BLDG. 2

BUILDING NO. WHERE EQUIPMENT IS LOCATED.

AHU NUMBER

EQUIPMENT ABBREVIATION. AN "(E)" SHOWN IN FRONT OF EQUIPMENT TAGS NOTIFIES

THAT EQUIPMENT IS EXISTING

ITEM NUMBER (TERMINAL UNIT NO. 1)

ITEM (TERMINAL UNIT SHOWN)

SERVED BY AIR HANDLER UNIT NO. 1

BUILDING NO. WHERE EQUIPMENT IS LOCATED

H4

H7

A

SHEET NUMBER

H ROOM HUMIDITY SENSOR - WALL MOUNT

ABBR. DESCRIPTION

(E) EXISTING

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

ECC ENGINEERING CONTROL CENTER

EF EXHAUST FAN

ENT ENTERING

ESP EXTERNAL STATIC PRESSURE

ET EXPANSION TANK

EWT ENTERING WATER TEMPERATURE

F FAHRENHEIT

FC FLEXIBLE CONNECTION

FCU FAN COIL UNIT

FD FIRE DAMPER

FF FINAL FILTER

FPM FEET PER MINUTE

FPS FEET PER SECOND

FS FLOW SWITCH

FSD COMBINATION FIRE SMOKE DAMPER

GPM GALLONS PER MINUTE

HC HEATING COIL

HD HEAD

HOA HAND/OFF/AUTOMATIC

HP HEAT PUMP

HP HORSEPOWER

HPDT HIGH PRESSURE DRIP TRAP

HPR HIGH PRESSURE RETURN (STEAM CONDENSATE)

HPS HIGH PRESSURE SUPPLY (STEAM)

HWHC HEATING HOT WATER COIL

HHWR HEATING HOT WATER RETURN

HHWS HEATING HOT WATER SUPPLY

HE HEAT EXCHANGER

HZ HERTZ

I/O INPUT/OUTPUT

IN INCHES

IN WC INCH WATER COLUMN

IPLV INTEGRATED PART LOAD VALUE

ABBR. DESCRIPTION

SAT SUPPLY AIR TEMPERATURE

SD SMOKE DETECTOR

SD SMOKE DAMPER

SEN SENSIBLE HEAT

SP STATIC PRESSURE

SPS STATIC PRESSURE SENSOR

SQ FT SQUARE FOOT (FEET)

SS STAINLESS-STEEL

TAB TESTING, ADJUSTING, BALANCE

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

TU TERMINAL UNIT

TYP TYPICAL

UL UNDERWRITERS LABORATORY

VAV VARIABLE AIR VOLUME

VD VOLUME DAMPER (MANUAL OPPOSED BLADE)

VFD VARIABLE FREQUENCY DRIVE

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.

TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.

2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR

FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH

AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO

OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST.

3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC

DUCT CONSTRUCTION STANDARD.

4. INSTALL ALL FIRE DAMPERS, SMOKE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS IN

ACCORDANCE WITH MANUFACTURE'S INSTALLATION DIRECTIONS. PROVIDE ACCESS DOORS TO

ALLOW COMPLETE INSPECTION AND MAINTENANCE OF ALL DEVICES.

5. CONTRACTOR SHALL PROVIDE LIST BY ROOM NUMBER LOCATION FOR NEW FIRE DAMPERS, SMOKE

DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS.

6. CONTRACTOR PROVIDE PHOTOS SHOWING NEW FIRE DAMPERS, SMOKE DAMPERS AND

COMBINATION FIRE/SMOKE DAMPERS IN OPEN AND CLOSED POSITION.

7. PROVIDE 1.5R ELBOWS IN DUCTWORK AS INDICATED. IF 1.5R ELBOWS DO NOT FIT, PROVIDE 1.0R ELBOWS. IF 1.0R ELBOWS DO NOT FIT, PROVIDE 90 DEGREE RECTANGULAR DUCT ELBOWS WITH

TURNING VANES.

8. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT

FURNISHED.

9. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48"

ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER

EQUIPMENT, FURNITURE, AND DOOR SWINGS.

10. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE

ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.

11. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.

12. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE

PAINTED FLAT BLACK.

13. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.

14. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR

PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED.

15. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR

OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.

16. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO

FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.

17. COORDINATE SIZE REQUIREMENTS OF ALL CONCRETE HOUSEKEEPING PADS UNDER ALL FLOOR-

MOUNTED EQUIPMENT.

18. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS

AND OTHER AIR DISTRIBUTION DEVICES.

19. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO FANS, AIR HANDLING

UNITS, AND FAN COIL UNITS.

20. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE

CONNECTED.

21. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS.

22. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.

23. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 25'-0" CLEAR FROM ALL PLUMBING VENTS. LOWEST

POINT OF EACH OUTSIDE AIR INTAKE ON ROOF SHALL BE A MINIMUM OF 24" ABOVE ROOF.

24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.

25. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. DUCT SIZES

ARE NET INSIDE DIMENSIONS.

26. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING

DIFFUSERS, REGISTERS, AND GRILLES.

27. ALL DDC CONTROL PANELS SHALL BE LOCKABLE.

ZC VALVE OR DAMPER POSITION CONTROLLER

PDS PRESSURE DIFFERENTIAL TRANSMITTER

TT TEMPERATURE TRANSMITTER, AVERAGING ELEMENT

TSL TEMPERATURE SWITCH, LOW (FREEZESTAT)

FS FLOW SWITCH

IT CURRENT TRANSMITTER

MT MOISTURE (HUMIDITY) TRANSMITTER

HS HAND SWITCH (HAND-OFF-AUTO SWITCH)

ECC

VSMC

INTEGRATE CONTROL POINT ON REMOTE GRAPHICS

WORKSTATION AT ENERGY CONTROL CENTER

VARIABLE SPEED MOTOR CONTROLLER

AFMD AIR FLOW MEASURING DEVICE

VALVE SYMBOLS

SYMBOL DESCRIPTION

SD SMOKE DAMPER

MOTOR STARTER

PSH PRESSURE SWITCH HIGH

SPS STATIC PRESSURE SENSOR

SD SMOKE DETECTOR

PC

PRESSURE CONTROLLER. SEE SEQUENCE OF

OPERATION

ECM AIR FLOW MEASURING DEVICE

ZS DAMPER POSITION FEEDBACK TO ECC

TE TEMPERATURE ELEMENT

COMBINATION FIRE/SMOKE DAMPER

STAINLESS STEEL DUCT

FSD

AUTOMATIC CONTROL DAMPER MODULATING

GENERAL EQUIPMENT SYMBOLS

EQUIPMENT WITH CLEARANCE

CLEARANCE

EQUIPMENT

SYMBOL DESCRIPTION

QUICK-COUPLE HOSE CONNECTOR

SIDE CONNECTION

ECCENTRIC REDUCER

BOTTOM CONNECTION, 45° OR 90°

TOP CONNECTION, 45° OR 90°

UNION

RISE OR DROP IN PIPE

CAPPED OUTLET

PRESSURE GAGE

THERMOMETER

FLOW ELEMENT

PIPE UP

PIPE DOWN

REFRIGERANT SIGHT GLASS

TEST PLUG (PRESSURE/TEMPERATURE)

AUTOMATIC AIR VENTAV

MANUAL AIR VENTMV

FE

THERMOSTATIC TRAP SET INCLUDING PIPING ACCESSORIES

SEE DETAIL

VANED ELBOW (PROVIDE ALL SQUARE OR

RECTANGULAR ELBOWS WITH VANES EVEN IF

SYMBOL IS MISSING)

PIPING SYMBOLS

HIGH PRESSURE STEAM CONDENSATE RETURN

HIGH PRESSURE STEAM (60 PSIG AND ABOVE)

HEATING HOT WATER SUPPLY

CONDENSATE PUMP DISCHARGE

LOW PRESSURE STEAM CONDENSATE RETURN

LOW PRESSURE STEAM (15 PSIG AND BELOW)

MEDIUM PRESSURE STEAM CONDENSATE RETURN

MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)

CHILLED WATER SUPPLY

CHILLED WATER RETURN

HEATING HOT WATER RETURN

HPS

HPR

MPS

MPR

LPS

LPR

PC

HHWS

HHWR

CHWR

CHWS

SYMBOL DESCRIPTION

CONDENSATECD

CONDENSATE CLEANOUTCO

REDUCER OR INCREASER

DIRECTION OF FLOW

LC

M

WATER LEVEL CONTROLLER

FLOW METER

BALL VALVE

CHECK VALVE

ANGLE GLOBE VALVE

BUTTERFLY VALVE

MODULATING CONTROL VALVE

THREE-WAY MODULATING CONTROL VALVE

PRESSURE SAFETY VALVE

WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)

FLEXIBLE CONNECTION

GLOBE VALVE

HVAC SYMBOL LEGEND

HVAC GENERAL NOTES

CEILING ACCESS HATCH

M

AIRFLOW CONTROL VALVE

ACV GATE VALVE

BUTTERFLY VALVE

PRESSURE REDUCING VALVE

FLEXIBLE CONNECTION

WYE STRAINER (WITH BALL VALVE &

HOSE CONNECTION)

WYE STRAINER (WITH VALVE DRAIN &

QUICK-COUPLE HOSE CONNECTION)

DUCT SMOKE DETECTOR

CALIBRATED BALANCING VALVE

A 200

DEVICE MARK

DEVICE FLOW RATE (CFM)

12X10 SA

DUCT DIMENSION (INCHES)

TYPICAL AIR DISTRIBUTION DEVICE TAG

TYPICAL DUCTWORK TAG

SYSTEM TYPE (SA = SUPPLY AIR , RA = RETURN

AIR, OA = OUTSIDE AIR, EA = EXHAUST AIR,

SS EA = STAINLESS-STEEL EXHAUST)

INVERTED BUCKET TRAP SET INCLUDING PIPING

ACCESSORIES SEE DETAIL LEVEL EQUIPMENT LOCATED ON / LEVEL IT SERVES

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

3:

:3

P M

M-001

MECHANICAL LEGENDS,

SYMBOLS, & GENERAL NOTES

EXPAND EMERGENCY

DEPARTMENT AT LAKE NONA

Orlando, Florida

675-901

08/13/2021 KJD JJAKyle J. Davis, P.E.

FL License #84275

Kevin Glover - COR

SHEET LIST

Sheet Number Sheet Name

M-001 MECHANICAL LEGENDS, SYMBOLS, & GENERAL NOTES

MD111 MECHANICAL HVAC DEMO PLAN - LEVEL 1

MH111 MECHANICAL HVAC PLAN - LEVEL 1

MH112 MECHANICAL HVAC PLAN - LEVEL 1 ROOF

MP111 MECHANICAL PIPING PLAN - LEVEL 1

MP112 MECHANICAL PIPING PLAN - LEVEL 1 INTERSTITIAL

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-701 MECHANICAL CONTROLS

M-801 MECHANICAL SCHEDULES

10x10 SA(E)

1 T

6.2 5.2 4.2 3.2 2.2

C.2

A.2

D.2

B.2

1.2

C

B

C.6

A.6

34.5 34.2

5.8 4.8 3.8 2.8 1.4

35 34.4

A.01

35.4

D.3

5.0

J.14

P R

O F

E S

S

I O NA L E NG

I N

E E

R

L I CENSE

F L O R I DA

STATE

No. 84275

SIVAD.JELYK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

FULLY SPRINKLERED

A1 A2

A3

B2 B1

C1

D1 D2 D3

E1 E2 E3

KEY PLAN

NTS

A4

E4

B

IM

O rla nd o V

A L ak e

N on a E

D E xp an si on

/0

L ak e N on a

E R

E xp an si on D iv

1, 2, R

.r vt 8/

/2

3:

:4

P M

MD111

MECHANICAL HVAC DEMO PLAN

- LEVEL 1

EXPAN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .