This pre-solicitation notice outlines requirements for a two-phase design-build contract to renovate Building 223 for pandemic storage at the Minneapolis VA Health Care System. The Department of Veterans Affairs seeks to completely renovate the interior and exterior of the building, sectioning it into three areas - a semi-conditioned storage space for Facilities Engineering, a conditioned storage space for Logistics with pallet racking, and a conditioned storage and secure cage area for Logistics and pandemic supplies. The anticipated period of performance is 365 calendar days from contract award. Phase I proposals are due on or about February 12, 2021, with phase II award estimated for June 30, 2021. The project magnitude is $2-5 million and is set aside 100% for Service-Disabled Veteran Owned Small Businesses.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
07-21-2017
/2
/2
:0 :4
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-GI001
COVER SHEET
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
ARCHITECT
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
CONTACT: TOM OLESAK
PHONE: 763-412-4000
MECHANICAL/PLUMBING
ENGINEER
DUNHAM
50 SOUTH 6th STREET SUITE 1100
MINNEAPOLIS, MN 55402
CONTACT: JASON GOTTWALT
PHONE: 612-465-7648
ELECTRICAL ENGINEER
DUNHAM
50 SOUTH 6th STREET SUITE 1100
MINNEAPOLIS, MN 55402
CONTACT: CURT BARLAGE
PHONE: 612-465-7641
STRUCTURAL ENGINEER
LHB INC
701 WASHINGTON AVENUE NORTH
SUITE 200
MINNEAPOLIS, MN 55401
CONTACT: STEPHEN W. HEARN
PHONE: 612-752-6932
OWNER:
DEPARTMENT OF VETERANS AFFAIRS
708 S. THIRD STREET, SUIT 200
MINNEAPOLIS, MN 55415
CONTACT: RYAN VAN SCHYNDEL
PHONE: 612-467-2484
FAX:
COST CONSULTANT
CPMI
3265 NORTHWOOD CIRCLE
SUITE 170
EAGAN, MN 55121
CONTACT: BRYAN BERTRAND
PHONE: 952-854-3663
PLAN
NORTH
TR
U E
N O R
TH
TRUE
NORTH
TRUE
NORTH
VA PROJECT NUMBER:
OWNER & CONSULTANTS
VICINITY MAP SITE LOCATION MAPFORT SNELLING SITE AREA MAP
EXISTING
BUILDING
GOLF COURSE
PARK
EXISTING
BUILDING
B L O
O M
IN
G
T O
N R
D
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
BUILDING 222, BUILD OUT PACKAGE
FORT SNELLING
618-18-100
ENVIRONMENTAL CONSULTANT
INSTITUTE FOR ENVIROMENT
ASSESSMENT
9201 WEST BROADWAY
BROOKLYN PARK, MN 55445
CONTACT: BILL DOLD
PHONE: 763-315-7900
ROOT HOUSE
65% Design Concurrence
End User:
1969 Union:
3669 Union:
Logistics:
SPS:
EMS:
BIS:
95% Design Concurrence
End User:
1969 Union:
3669 Union:
Shops:
Safety Committee:
BIS:
Project Approval:
End User:
1969 Union:
3669 Union:
Engineering Project Chief
Engineering Director
No. Revisions Date
ACCESSIBLITY SYMBOLOGY LEGEND
DOOR CLEARANCES.
FRONT APPROACHES INDICATED,
SEE PLANS AND CODES FOR SIDE
APPROACHES.
ø 5' - 0"
4' - 0"
1' - 0"
1' - 6"
CLEAR FLOOR SPACE
TURNING SPACE
1' - 0" 3' - 0" 1' - 0"
5' - 0"
IF BOTH CLOSER AND LATCH PROVIDED
DETAIL INDICATOR-PLAN
ARCHITECTURAL SYMBOLS
1 View Name
1/8" = 1'-0"A101
INTERIOR ELEVATION INDICATOR
ELEVATION INDICATOR
ROOM NAME & NUMBER
DRAWING BLOCK TITLE
SECTION INDICATOR
Room name
WALL PARTITION TYPE
NORTH ARROW
NORTH
PROPERTY LINE
DOOR OPENING IDENTIFIER
WINDOW TYPE IDENTIFIER
DIMENSION LINE1' - 6"
MATERIAL SYMBOLS
BASE COURSE
CONCRETE
EARTH
SAND / MORTARBRICK
CONCRETE MASONRY
UNIT
STONE
STEEL / ALUMINUM
EXIST CONSTRUCTION
TO BE REMOVED
WOOD
PLYWOOD
BATT INSULATION
CENTER LINE INDICATOR
CONTRACT LIMIT LINE
DEMOLITION LINE
FEATURES ABOVE LINE
HIDDEN FEATURES LINE
MATCHLINE
EXIST CONSTRUCTION
TO REMAIN
VV ITEM - VA SUPPLIED &
INSTALLED
CC ITEM - VA SUPPLIED &
INSTALLED
VC ITEM - VA SUPPLIED &
CONTRACTOR INSTALLED
A2
A-202 D B
A
C
1A KEYNOTE
ROOM FINISH TAG
EXISTING DOOR TO REMAIN
CEILING
WALLS
FLOORING
BASE TRIM
WXXX
PXX
XXXX
AS101
AS101
Name Elevation
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
07-21-2017
/2
/2
:0 :4
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-GI002
SHEET INDEX, SYMBOLS AND
MATERIALS
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
SHEET INDEX
Current sheet No
Drawing Number Drawing Title
53 MR3101 MECHANICAL PLAN - ROOF
09 ELECTRICAL
54 E3000 ELECTRICAL TITLE SHEET
55 ED3101 ELECTRICAL DEMOLITION PLAN - LOWER LEVEL
56 ED3102 ELECTRICAL DEMOLITION PLAN - MAIN LEVEL
57 ED3103 ELECTRICAL DEMOLITION PLAN - ATTIC LEVEL
58 EL3101 LIGHTING PLAN - LOWER LEVEL
59 EL3102 LIGHTING PLAN - MAIN LEVEL
60 EL3103 LIGHTING PLAN - ATTIC LEVEL
61 EP3101 POWER PLAN - LOWER LEVEL
62 EP3102 POWER PLAN - MAIN LEVEL
63 EP3103 POWER PLAN - ATTIC LEVEL
64 ES3101 SIGNAL PLAN - LOWER LEVEL
65 ES3102 SIGNAL PLAN - MAIN LEVEL
66 ES3103 SIGNAL PLAN - ATTIC LEVEL
67 E3201 ELECTRICAL DETAILS
68 E3301 ELECTRICAL RISER DIAGRAM
69 E3401 ELECTRICAL SCHEDULES
70 E3402 LIGHTING SCHEDULES
71 E3501 ENLARGED ELECTRICAL PLANS
SHEET INDEX
Current sheet No
Drawing Number Drawing Title
01 GENERAL
1 GI001 COVER SHEET
2 GI002 SHEET INDEX, SYMBOLS AND MATERIALS
3 GI003 ABBREVIATIONS
05 ARCHITECTURAL
4 AS001 LIFE SAFETY PLAN - LOWER LEVEL
5 AS002 LIFE SAFETY PLAN - MAIN LEVEL
6 AS003 LIFE SAFETY PLAN - ATTIC LEVEL
7 AS101 DEMOLITION PLAN AND FLOOR PLAN - LOWER LEVEL
8 AS102 DEMOLITION PLAN AND FLOOR PLAN - MAIN LEVEL
9 AS103 DEMOLITION PLAN AND FLOOR PLAN - ATTIC LEVEL
AS104 NOT USED
10 AS105 REFLECTED CEILING PLAN - LOWER LEVEL
11 AS106 REFLECTED CEILING PLAN - MAIN LEVEL
12 AS107 REFLECTED CEILING PLAN -ATTIC LEVEL
13 AS401 ENLARGED PLANS AND INTERIOR ELEVATIONS
14 AS402 INTERIOR ELEVATIONS AND SECTIONS
15 AS601 INTERIOR DETAILS
16 AS602 INTERIOR DETAILS
17 AS701 INTERIOR PARTITION TYPES AND DETAILS
18 AS702 OPENING SCHEDULE AND DETAILS
19 AF100 FINISH SCHEDULE
20 AF101 FINISHES PLAN- LOWER LEVEL
21 AF102 FINISHES PLAN - MAIN LEVEL
22 AF103 FINISHES PLAN - ATTIC LEVEL
23 AF104 SIGNAGE - LOWER LEVEL
24 AF105 SIGNAGE - MAIN LEVEL
25 AF106 SIGNAGE - ATTIC LEVEL
06 INTERIORS
26 IF101 FURNITURE AND EQUIPMENT PLAN - LOWER LEVEL
27 IF102 FURNITURE AND EQUIPMENT PLAN - MAIN LEVEL
28 IF103 FURNITURE AND EQUIPMENT PLAN - ATTIC LEVEL
08 MECHANICAL
29 M3000 MECHANICAL TITLE SHEET
30 M3201 MECHANICAL DETAILS AND DETAIL VIEWS
31 M3202 VRF REFRIGERANT PIPING SCHEMATIC
32 M3301 WATER RISER DIAGRAMS
33 M3302 WASTE AND VENT RISER DIAGRAMS
34 M3401 MECHANICAL SCHEDULES
35 M3501 MECHANICAL AND ELECTRICAL SCHEDULES
36 MD3100 MECHANICAL DEMOLITION PLANS
37 MF3101 FIRE PROTECTION PLAN - LOWER LEVEL
38 MF3102 FIRE PROTECTION PLAN - MAIN LEVEL
39 MF3103 FIRE PROTECTION PLAN - ATTIC LEVEL
40 MH3101 HVAC PLAN - LOWER LEVEL
41 MH3102 HVAC PLAN - MAIN LEVEL
42 MH3103 HVAC PLAN - ATTIC LEVEL
43 MM3101 HEATING PIPING PLAN - LOWER LEVEL
44 MM3102 HEATING PIPING PLAN - MAIN LEVEL
45 MM3103 HEATING PIPING PLAN - ATTIC LEVEL
46 MM3201 REFRIGERATION PIPING PLAN -LOWER LEVEL
47 MM3202 REFRIGERATION PIPING PLAN -MAIN LEVEL
48 MM3203 REFRIGERATION PIPING PLAN -ATTIC LEVEL
49 MP3100 PLUMBING PLAN - UNDERGROUND
50 MP3101 PLUMBING PLAN - LOWER LEVEL
51 MP3102 PLUMBING PLAN - MAIN LEVEL
52 MP3103 PLUMBING PLAN - ATTIC LEVEL
GENERAL CLEANING NOTES
1. REMOVE DEBRIS FROM BUILDING.
2. REMOVE LOOSE CHIPPED OR PEELING PAINT AND OTHER
SURFACE RESIDUE FROM EXIST EXPOSED SURFACES.
3. CLEAN EXISTING SURFACES SCHEDULED TO REMAIN.
4. VACUUM CLEAN EXPOSED STRUCTURAL ELEMENTS TO REMAIN
EXPOSED.
5. VACUUM CLEAN "UNASSIGNED" SPACES GENERALLY ACCESSIBLE
TO BUILDING OCCUPANTS.
6. AT COMPLETION OF WORK, REMOVE REMAINING WASTE
MATERIALS, RUBBISH, TOOLS, EQUIPMENT, MACHINERY AND
SURPLUS MATERIALS. CLEAN ALL EXPOSED SURFACES. LEAVE
PROJECT CLEAN AND READY FOR OCCUPANCY PROVIDE FINAL
CLEANING IN ACCORDANCE WITH ASTM E1971.
A. DAMP MOP RESILIENT, TILE AND WOOD FLOORS.
B. VACUUM CLEAN CARPETED FLOORS.
C. CLEAN CERAMIC TILE WALLS.
D. CLEAN WINDOWS MIRRORS AND OTHER GLAZED
SURFACES.
GENERAL NOTE:
ITEMS IDENTIFYING A SPECIFIC MANUFACTURER AND MODEL ARE
FOR REFERENCE ONLY. ITEMS FROM OTHER MANUFACTURERS
WHICH MEET THE PERFORMANCE CRITERIA OF THE NAMED
MANUFACTURER CAN BE SUBSTITUTED WITH PRIOR APPROVAL OF
THE COR.
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURSIDICATION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONST
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STADARDS INSTITUTE
ANT ANTENNA
AP ACCESS PANEL
APPD APPROVED
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT(URAL)
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSOC ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING &
MATERIALS
ATCH ATTACHMENT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWPA AMERICAN WOOD PRESERVERS' ASSOC
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEV BEVEL
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM
BOT BOTTOM
BR BEDROOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C CELSIUS
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN OR CORNER BEAD
CBB CEMENTITIOUS (BACKER) BOARD
CC CLEAR COAT
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFLG COUNTERFLASHING
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CONST J CONSTRUCTION JOINT
CJ CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CM CONSTRUCTION MANAGEMENT
CMU CONCRETE MASONRY UNIT
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE
CO2 CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
COND CONDENSER
CONF CONFERENCE
CONN CONNECT
CONST CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE
DL DEAD LOAD
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT
DSGN DESIGN
DW DISHWASHER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD (INSUL)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC ET CETERA
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXP BT EXPANSION BOLT
EXST GR EXISTING GRADE
EXT EXTERIOR
F FAHRENHEIT
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FFE FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD
FHC FIRE HOSE CABINET
FHP FULL HEIGHT PARTITION
FIG FIGURE
FIL FILLET
FIN FINISH
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FL FLOOR
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FM FACTORY MUTUAL
FO FINISHED OPENING
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING
FRMG FRAMING
FRP FIBER REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH
FUT FUTURE
FWC FABRIC WALLCOVERING
GA GAGE
GAL GALLON
GALV GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GDR GUARD RAIL
GEN GENERAL
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HF HIGH FREQUENCY
HGR HANGER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDFHOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH POINT
HPD HYGIENE PRODUCT DISPOSAL
HPDL HIGH PRESSURE DECORATIVE LAMINATE
HQ HEADQUARTERS
HS HEAT-STRENGTHENED (GLASS)
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND A/C
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX JUNCTION BOX
KD KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LB POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET
LH LEFT HAND
LHR LEFT HAND REVERSE
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD METAL DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MED MEDICAL MEDIUM
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MASONRY OPENING
MOD MODIFY
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS ASSOC
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OH OVERHANG
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM
ORD OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINSTRATION
OUT OUTLET
OZ OUNCE
PAR PARALLEL
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PKG PACKAGE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINT METAL
PNEU PNEUMATIC
PNL PANEL
PO POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTM PATCH TO MATCH EXISTING
PTN PARTITION
PVC POLYVINYL CHLORIDE
PVG PAVING
PWR POWER
QA/QC QUALITY ASSURANCE/QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE
REFR REFRIGERATION
REG REGISTER
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ/D REQUIRE/REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RWD REDWOOD
RWL RAIN WATER LEADER
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SAT SUSPENDED ACOUSTICAL TILE
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SMOKE DETECTOR, OR SOAP
DISPENSER
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STNLS STAINLESS
STOR STORAGE
STRUCT STRUCTURAL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE
TMPRY TEMPORARY
TER TERRAZZO
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK
TRANS TRANSOM
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WATER CLOSET
WCHR WATER CHILLER
WCL WATER COOLER
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE BOARD (INSUL)
YD YARD
YR YEAR
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
07-21-2017
/2
/2
:0 :4
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-GI003
ABBREVIATIONS
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 713No. Revisions Date
UP
UP
DN
UP
UP
UP
UP
FD
FD
FD
FD
7 8 9 10
B
C
11 12 13 14 15 16 17 18 20 21 226321 5
A
D
1.1 3.1 3.2 3.3 3.4
F
H
J
K
L
19.1
19.1
E
I
19 21.2 21.3
G
7.1 9.1 11.1 13.1 15.1 17.15.1
I.1
K.1
L.1
H
R E
X
IT
P A
S S
A G
E W
A Y
FEC
FEC FEC
EXIT 1:
(EXIST)
60"
EXIT 2:
(EXIST)
34"
EXIT 3:
(EXIST)
73"
EXIT 4:
(EXIST)
36"
F E
C
EXISTING OPEN
OFFICE
EXISTING
CONFERENCE
102 EXISTING OPEN
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
BREAK
EXISTING
VEST
EXISTING
WOMEN
EXISTING
MEN
EXISTING
LOBBY
EXISTING
VESTIBULE
EXISTING
ELEV EQUIP
EXISTING
WORK ROOM
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
CONFERENCE
EXISTING
PASSAGE
EXISTING
OPEN OFFICE
EXISTING
CONFERENCE
EXISTING
PASSAGE
EXISTING
OFFICE
EXISTING
OFFICE
E X
IS
T
IN
G
P A
S S
A G
E
EXISTING
BREAK
EXISTING
WOMEN
EXISTING
MEN
EXISTING
HSKPG
EXISTING
STORAGE
E X
IS
T
IN
G
E X
IT
P
A S
S A
G E
W A
Y
EXISTING
DATA
EXISTING BOILER
ROOM
EXISTING
WAREHOUSE
EXISTING
ELECTRICAL
ROOM
EXISTING
LOBBY
EXISTING
STAIR A
EXISTING
ELECT
EXISTING
VESTIBULE
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
OFFICE
OFFICE
OPEN OFFICE
EXISTING
STAIR B
EXISTING VESTIBULE
ELEC
CLOSET
144A
ELEV
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:2 :3
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS001
LIFE SAFETY PLAN - LOWER
LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
LIFE SAFETY PLAN - LOWER
LEVEL
Building Code Review
a) Sec 304 Occupancy Group B
b) Sec 508.3 Mixed Occupancy: No separation required between B and S-1
c) Sec 602.3 Type of Construction Type IIIB, fully sprinklered: (exterior walls constructed of non-combustible materials, interior elements constructed of any material allowed by the Code.)
d) Sec 502.1 Allowable Height: 55 feet, 3 stories (existing building is 35 feet at highest ridge)
e) Sec 503 Allowable Floor Area: 19,000 sq ft
f) Sec 506.2 Allowable Area Increase
Aa = {At + [At x If] + [At x Is]}, where If = [F/P - .25] W/30 Aa = {19,000 + [19,000 x .5383] + [19,000 x 2]}
Aa = {19,000 + 10,227.7 + 38,000} Aa = 67,227.7 (existing building is 28,511)
If = [F/P - .25]W/30 If = [668.5/848 - .25]30/30 If = [.7883 - .25] 1 If = .5383
g) Sec 1004.1 Occupant Load:
Basement (incl Root House): 12,203 sq ft First Floor 8,154 Second Floor 8,154 TOTAL 28,511 sq ft Office occupancy = 100 sq ft/ person TOTAL OCCUPANT LOAD 285 occ
h) Sec 1005.1 Egress Width Stairs: Occ load x .3”
285 x .3” = 85.5” 85.5/2 = 42.75 (minimum 48” required)
Other Elements: Occ load x .2” 285 x .2” = 57” 57/2 = 28.5 (minimum 32” clear required at doors)
i) Sec 1016 Maximum travel distance = 300 feet (fully sprinklered building)
j) Sec 1017.2 Minimum aisle width = 36”
k) Sec 1018.4 Maximum “Dead End” Corridor = 20’
l) Sec 1021 Number of exits required: (Table 1021.1: occ load 1-500, then 2 exits required per floor (story)
LIFE SAFETY ZONE LEGEND
RATED FIRE PARTITION
= 1 HR FIRE PARTITION
SYMBOL LEGEND
FIRE EXTINGUISHER CABINETFEC
XXX NUMBER OF OCCUPANTS PASSING THROUGH DOOR
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
2. FILL HOLES AND OPENINGS IN EXISTING FLOOR WITH A TESTED AND
APPROVED FIRE STOPPING SYSTEM.
EXIT SIGN
4No. Revisions Date
JTuchtenhagen Line
JTuchtenhagen Line
JTuchtenhagen Line
JTuchtenhagen Line
DN
DN
DN
DN
DN
FD
FD
7 8 9 10
B
C
11 12 13 14 15 16 17 18 20 21 2265
A
D
F
H
J
K
L
19.1
19.1
E
I
19 21.2 21.3
G
7.1 9.1 11.1 13.1 15.1 17.15.1
I.1
K.1
L.1
DN
FEC
FEC
FEC
FEC
EXISTING
CONFERENCE
EXISTING
MECH
201A
EXISTING
OPEN OFFICE
EXISTING
LOBBY
EXISTING
PASSAGE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
GALLERY
EXISTING
PASSAGE
EXISTING
TEAM
EXISTING
TEAM
EXISTING
OPEN OFFICE
EXISTING
PASSAGE
EXISTING
MEN
EXISTING
WOMEN
EXISTING
BREAK ROOM
E X
IS
T
IN
G
P A
S S
A G
E
PASSAGE
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
EXISTING
ELECTRICAL
EXISTING
LOADING DOCK
ATTIC SPACE
CONSULT
ROOM
CONSULT
ROOM
226CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
OPEN OFFICE
PASSAGE
CONFERENCE
CONSULT
ROOM
PASSAGE
CONSULT
ROOM
MECH
TOILET
OFFICE
UP
ELEC
CLOSET
244A
ELEV
WAREHOUSE
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:2 :3
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS002
LIFE SAFETY PLAN - MAIN
LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
LIFE SAFETY PLAN - MAIN
LEVEL
LIFE SAFETY ZONE LEGEND
RATED FIRE PARTITION
= 1 HR FIRE PARTITION
SYMBOL LEGEND
FIRE EXTINGUISHER CABINETFEC
XXX NUMBER OF OCCUPANTS PASSING THROUGH DOOR
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
2. FILL HOLES AND OPENINGS IN EXISTING FLOOR WITH A TESTED AND
APPROVED FIRE STOPPING SYSTEM.
EXIT SIGN
5No. Revisions Date
JTuchtenhagen Line
J J J
J
J
J
J
J
J
J
J
J
J
J
J
7 8 9 10
B
C
11 12 13 14 15 16 17 18 20 21 2265 23
A
D
F
H
J
K
L
19.1
19.1
E
I
19 21.2 21.3
G
7.1 9.1 11.1 13.1 15.1 17.15.1
I.1
K.1
L.1
FEC
FEC
FEC
EXISTING
OPEN OFFICE
EXISTING
TEAM
EXISTING
DATA ROOM
301A
EXISTING
LOBBY
PASSAGE
CONFERENCE
CONSULT
ROOM
ATTIC
309A
MEN
WOMEN
ATTIC
313A
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
PASSAGE
CONSULT
ROOM
ATTIC
310A
ELEV
WAREHOUSE
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:2 :3
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS003
LIFE SAFETY PLAN - ATTIC
LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
LIFE SAFETY PLAN - ATTIC
LEVEL
LIFE SAFETY ZONE LEGEND
RATED FIRE PARTITION
= 1 HR FIRE PARTITION
SYMBOL LEGEND
FIRE EXTINGUISHER CABINETFEC
XXX NUMBER OF OCCUPANTS PASSING THROUGH DOOR
GENERAL NOTES
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
2. FILL HOLES AND OPENINGS IN EXISTING FLOOR WITH A TESTED AND
APPROVED FIRE STOPPING SYSTEM.
EXIT SIGN
0 2' 4' 6' 8' 16' 32'
SCALE: 3/32" = 1'-0"
PLAN
NORTH
TR
U E
N O R
TH
6No. Revisions Date
JTuchtenhagen Line
UP
UP
FD
21 22
D
F
H
J
K
L
19.1
E
I
EXISTING
VESTIBULE
E X
IS
T
IN
G
E X
IT
P
A S
S A
G E
W A
Y
21.2 21.3
G
FFE=
-2'-2 3/8"
EXISTING VESTIBULE
P3
P3
AS401
5' - 0" 11' - 8 1/2"
UP
P3
P3
P3
P3
AS601
L
IM
IT
O
F W
O R
K
LIMIT OF WORK
FFE=
-2'-2 3/8"
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
P3
CONSULT
ROOM
OFFICE
OFFICE
/4
E Q
E Q
E Q
E Q
OPEN OFFICE
2 1/2" CONC
TOPPING
TO BE LEVEL
WITH EXIST
EXIT
PASSAGEWAY
P3
P3
P3
144A
" P1A
10' - 6"
P1 INFILL
EXISTING
STAIR B
REINSTALL
SALVAGED DOOR
ASSEMBLY
CENTER
PARTITION
ON COLUMN
P3
AS601
AS601
CENTER
PARTITION
ON COLUMN
P3
WALL TO ALIGN WITH
UNDERSIDE OF
BEAM SOFFIT
45.00°
45.00°
AS602
P3
ELEC
CLOSET
144A
21 22
D
F
H
J
K
L
STORE HOUSE
(F-19)
A N
N E
X
19.1
E
I
21.2 21.3
G
REMOVE EXIST
WD FLOORING
AND SLEEPERS
REMOVE DOOR ASSEMBLY.
SALVAGE FOR REUSE
AS NOTED
REMOVE PORTION OF
EXIST GYP BD ON METAL
STUD PARTITION FOR
DOOR ASSEMBLIES.
LOCATE BASED ON
DIMENSIONS AND DETAILS
PROVIDED ELSEWHERE ON
DRAWINGS
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:0 :1
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS101
DEMOLITION PLAN AND
FLOOR PLAN - LOWER LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
FLOOR PLAN- LOWER LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
FLOOR PLAN GENERAL NOTES
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
2. PATCH HOLES AND SURFACES DAMAGED, ALTERED OR MODIFIED
BY THIS WORK WITH MATERIAL TO MATCH EXISTING ADJACENT
SURFACES.
3. FOR REFLECTED CEILING PLANS, SEE SHEETS AS105, AS106, AND
AS107.
4. FOR FINISH SCHEDULE, SEE SHEETS AF100, AF101, AF102, AND
AF103.
5. PARTITIONS ARE P1 UNLESS NOTED OTHERWISE. FOR PARTITION
TYPES, SEE SHEET AS701. PROVIDE TWO CONTINUOUS 6" H BANDS
OF BLOCKING AT 4'-0" AND 6'-0" A.F.F. IN PARTITION TYPE P1 IN
ROOMS LABELED "OFFICE", "TEAM", "CONFERENCE" OR "CONSULT".
6. ALIGN FINISHED FACE OF PARTITION WITH FACE OR EDGE OF
EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. PROVIDE
CONTINUOUS METAL J-BEAD TRIM AND 1/4" SEALANT JOINT AT
INTERFACE.
7. FOR OPENING SCHEDULE, SEE SHEET AS702.
8. IN ROOMS LABELED "HSKPG" PROVIDE MOP STRIP OVER FLOOR
SINK AND SHELF ADJACENT TO MOP STRIP, SEE 14/AS401 TYP.
9. PROVIDE SHADES ON ROOM SIDE OF BORROWED LIGHT FRAMES
THROUGHOUT.
10. UNNUMBERED DOORS/OPENINGS ARE EXISTING TO REMAIN.
11. PROVIDE ACCESS PANELS IN GYP BD PARTITIONS AND CEILINGS
WHERE SERVICE ACCESS TO MECHANICAL AND ELECTRICAL
EQUIPMENT IS REQUIRED- SEE MECHANICAL AND ELECTRICAL FOR
LOCATIONS.
DEMOLITION NOTES
1/8" = 1'-0"
DEMOLITION PLAN - LOWER
LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT IMMEDIATELY OF
ANY DISCREPANCIES.
2. REMOVE EXISTING CONSTRUCTION SHOWN DASHED AND AS NOTED, UNLESS
NOTED OTHERWISE. REMOVE ITEM OR ASSEMBLY IN ITS ENTIRETY INCLUDING
MOUNTING BRACKETS, HARDWARE, SUPPORTS AND OTHER APPURTENANCES.
SALVAGE AS NOTED OR DISPOSE OF PROPERLY.
3. PARTITIONS SHOWN TO BE REMOVED ARE WOOD PANELING, PLYWOOD OR FIBER
BOARD ON WOOD STUDS UNLESS NOTED OTHERWISE.
4. REMOVE DEBRIS, DIRT, DUST FROM EXISTING SURFACES THAT WILL
REMAIN EXPOSED AT THE COMPLETION OF WORK, OR TO PROPERLY ACCEPT
MATERIALS SPECIFIED UNDER THIS CONTRACT. ALSO SEE GENERAL CLEANING
NOTES ON SHEET GI002.
5. REMOVE MISCELLANEOUS FURRING, BRACKETS, FASTENERS, ETC. NO LONGER IN
USE FROM INTERIOR SURFACES THAT ARE SCHEDULED TO BE EXPOSED OR RECEIVE
FINISHES UNDER THIS CONTRACT.
DN
DN
UP
DN DN
21 22
D
F
H
J
K
L
EXISTING
STAIR B
EXISTING
ELEVATOR
19.1
E
I
P A
S S
A G
E
EXISTING
ELECTRICAL
21.2 21.3
G
9.1 11.1 13.1 15.1 17.1
I.1
K.1
L.1
DN
AS401
P4
P3
CONSULT
ROOM
11' - 3 1/4"
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
PATCH
EXISTING
PLASTER
TO MATCH
EXISTING-
ENTIRE WALL
/4
FEC
LIMIT OF WORK
L
IM
IT
O
F W
O R
K
PROVIDE
5/8" GYP BD
OVER EXIST
WOOD
COLUMN
COVER
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONFERENCE
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
PASSAGE
MECH
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
PASSAGE
CONSULT
ROOM
OPEN OFFICE
10' - 0" 9' - 11" 9' - 11" 9' - 11" 9' - 11"
EQ EQ EQ
AS402
9' - 6"
ALIGN
P4
EQ
OFFICE
TOILET
AS401
/2
244A
AS601
5' - 8 1/2"
/2
6' - 0"
AS402
AS402
D1
D1 D1
D1 D1
D1D1D1 D1
D1
D1 D1 D1
D1
D1
RAMP
P1A
P1A 1' - 7"
AS401 9
INFILL/PATCH
PLASTER
TO MATCH EXISTING,
AROUND WINDOWS
AS402
AS402
AS402
AS402
AS402
P1C P1C
P1C P1A P1C
AS402
ALIGN PARTITION ON
WINDOW MUNTIN/MULLION
5' - 2"
INFILL
PLASTER AT
EXIST CMU
6' - 4"
AS401
FFE= 7'-8 1/2"
F F
E
'-2
/2
DN
AS402
AS402
P1A
P1A P1A
P1A
P1A
EXIST BATTERY
CHARGER
INFILL PLASTER
AT EXIST CMU
P1A
PATCH
EXISTING
PLASTER
TO MATCH
EXISTING ALL
AROUND-
ENTIRE WALL
P4
AS601
"3' - 8 1/4"
CENTER
PARTITION
ON COLUMN
P1C
AS402
ELEC
CLOSET
244A
21 22
D
F
H
J
K
L
WAREHOUSE
STORE HOUSE
(F-19)
19.1
E
I
21.2 21.3
G
EXISTING
ELEVATOR
EXISTING
STAIRS
9.1 11.1 13.1 15.1 17.1
I.1
K.1
L.1
REMOVE EXIST WALLS
REMOVE EXIST
QUARRY TILE
FLOORING AND
PLUMBING FIXTURES
IN THIS ROOM
REMOVE METAL HANGERS
AND UNUSED ELECTRICAL
BOXES/WIRES AT CEILING-
EXISTING METAL CEILING TO
REMAIN
REMOVE EXIST
VCT IN THIS AREA
REMOVE EXIST METAL
CEILING PANELS IN THIS
AREA - SALVAGE
FOR REUSE ELSEWHERE
ON PROJECT (EXIST
PLASTER CEILING TO
REMAIN)
REMOVE EXIST "CHAIR
RAIL" AT ENTIRE
PERIMETER OF THIS
SPACE
REMOVE
EXISTING DOOR
AND SIDELIGHTS
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:0 :2
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS102
DEMOLITION PLAN AND
FLOOR PLAN - MAIN LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
FLOOR PLAN - MAIN LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
FLOOR PLAN GENERAL NOTES
1/8" = 1'-0"
DEMOLITION PLAN -MAIN
LEVEL
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
PLAN
NORTH
TR
U E
N O R
TH
DEMOLITION NOTES
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
2. PATCH HOLES AND SURFACES DAMAGED, ALTERED OR MODIFIED
BY THIS WORK WITH MATERIAL TO MATCH EXISTING ADJACENT
SURFACES.
3. FOR REFLECTED CEILING PLANS, SEE SHEETS AS105, AS106, AND
AS107.
4. FOR FINISH SCHEDULE, SEE SHEETS AF100, AF101, AF102, AND
AF103.
5. PARTITIONS ARE P1 UNLESS NOTED OTHERWISE. FOR PARTITION
TYPES, SEE SHEET AS701. PROVIDE TWO CONTINUOUS 6" H BANDS
OF BLOCKING AT 4'-0" AND 6'-0" A.F.F. IN PARTITION TYPE P1 IN
ROOMS LABELED "OFFICE", "TEAM", "CONFERENCE" OR "CONSULT".
6. ALIGN FINISHED FACE OF PARTITION WITH FACE OR EDGE OF
EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. PROVIDE
CONTINUOUS METAL J-BEAD TRIM AND 1/4" SEALANT JOINT AT
INTERFACE.
7. FOR OPENING SCHEDULE, SEE SHEET AS702.
8. IN ROOMS LABELED "HSKPG" PROVIDE MOP STRIP OVER FLOOR
SINK AND SHELF ADJACENT TO MOP STRIP, SEE 14/AS401 TYP.
9. PROVIDE SHADES ON ROOM SIDE OF BORROWED LIGHT FRAMES
THROUGHOUT.
10. UNNUMBERED DOORS/OPENINGS ARE EXISTING TO REMAIN.
11. PROVIDE ACCESS PANELS IN GYP BD PARTITIONS AND CEILINGS
WHERE SERVICE ACCESS TO MECHANICAL AND ELECTRICAL
EQUIPMENT IS REQUIRED- SEE MECHANICAL AND ELECTRICAL FOR
LOCATIONS.
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT IMMEDIATELY
OF ANY DISCREPANCIES.
2. REMOVE EXISTING CONSTRUCTION SHOWN DASHED AND AS NOTED, UNLESS
NOTED OTHERWISE. REMOVE ITEM OR ASSEMBLY IN ITS ENTIRETY INCLUDING
MOUNTING BRACKETS, HARDWARE, SUPPORTS AND OTHER APPURTENANCES.
SALVAGE AS NOTED OR DISPOSE OF PROPERLY.
3. PARTITIONS SHOWN TO BE REMOVED ARE WOOD PANELING, PLYWOOD OR
FIBER BOARD ON WOOD STUDS UNLESS NOTED OTHERWISE.
4. REMOVE DEBRIS, DIRT, DUST FROM EXISTING SURFACES THAT WILL
REMAIN EXPOSED AT THE COMPLETION OF WORK, OR TO PROPERLY ACCEPT
MATERIALS SPECIFIED UNDER THIS CONTRACT. ALSO SEE GENERAL CLEANING
NOTES ON SHEET GI002.
5. REMOVE MISCELLANEOUS FURRING, BRACKETS, FASTENERS, ETC. NO LONGER
IN USE FROM INTERIOR SURFACES THAT ARE SCHEDULED TO BE EXPOSED OR
RECEIVE FINISHES UNDER THIS CONTRACT.
REF.
DN
C
21 22
D
F
H
J
K
L
EXISTING
STAIR B
19.1
E
I
P A
S S
A G
E
21.2 21.3
G
ATTIC
309A
AS401
E Q
E Q
CONFERENCE
CONSULT
ROOM
11' - 5"
5' - 8"
FEC
FEC
L
IM
IT
O
F W
O R
K
LIMIT OF WORK
MEN
WOMEN
HSKPG
303A
12' - 10"
A
B
7' - 1"
A
P3
ATTIC
313A
SIM
P A
S S
A G
E
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
A
P1A
P1A
P3
P1A
10' - 11 1/2"
P3
310 313
312311
1' - 5"
7' - 1"
ATTIC
310A
.1
310.1
.1
.1
T Y
P
MASONRY
INFILL
CONSULT
ROOM
INFILL AND
REPAIR DAMAGED
OR MISSING BRICK
AT WINDOW SILL
INFILL WALL ABOVE
AND AROUND 7'-0"
OPENING
AS601
PROVIDE 5/8"
GYP BD
ON EXIST
WOOD FRAMING
PROVIDE 5/8"
GYP BD
ON EXIST
WOOD FRAMING
PROVIDE 5/8"
GYP BD
ON EXIST
WOOD FRAMING
CENTER PTN
ON COLUMN
CENTER PTN
ON COLUMN
INFILL RECESS AT
BASE OF COLUMN
TO BE FLUSH WITH
ADJACENT EXIST
STRIP FLOORING -
AT EACH COLUMN FROM
GRID E TO I
AS601
ALIGN
5' - 0"
P3
P3
AS402
24"x36"
ACCESS PANEL
STORAGE
AS402
21 22
D
F
H
J
K
L
STORE HOUSE
(F-19)
A N
N E
X
19.1
E
I
21.2 21.3
G
REMOVE EXISTING
LINOLEUM
FLOORING
REMOVE EXISTING WALL
AS REQUIRED FOR NEW
OPENING
REMOVE EXISTING
FIBERBOARD AND
STUDS
REMOVE EXISTING
WALL AS REQUIRED
FOR NEW OPENING
REMOVE DOOR AND
FRAME
REMOVE EXISTING
FIBERBOARD CEILING
REMOVE EXIST LEAD
BASED PAINT FOR
EXIST MASONRY TO
REMAIN
THESE ITEMS CONTAIN
LEAD BASED PAINT.
FOLLOW PROCEDURES
OUTLINED IN SPEC
SECTION 02 83 33.13
FOR REMOVAL AND
DISPOSAL
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:0 :2
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS103
DEMOLITION PLAN AND
FLOOR PLAN - ATTIC LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
FLOOR PLAN - ATTIC LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
FLOOR PLAN GENERAL NOTES
DEMOLITION NOTES
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
1/8" = 1'-0"
DEMOLITION PLAN - ATTIC
LEVEL
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
2. PATCH HOLES AND SURFACES DAMAGED, ALTERED OR MODIFIED BY
THIS WORK WITH MATERIAL TO MATCH EXISTING ADJACENT SURFACES.
3. FOR REFLECTED CEILING PLANS, SEE SHEETS AS105, AS106, AND
AS107.
4. FOR FINISH SCHEDULE, SEE SHEETS AF100, AF101, AF102, AND AF103.
5. PARTITIONS ARE P1 UNLESS NOTED OTHERWISE. FOR PARTITION
TYPES, SEE SHEET AS701. PROVIDE TWO CONTINUOUS 6" H BANDS OF
BLOCKING AT 4'-0" AND 6'-0" A.F.F. IN PARTITION TYPE P1 IN ROOMS
LABELED "OFFICE", "TEAM", "CONFERENCE" OR "CONSULT".
6. ALIGN FINISHED FACE OF PARTITION WITH FACE OR EDGE OF
EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. PROVIDE
CONTINUOUS METAL J-BEAD TRIM AND 1/4" SEALANT JOINT AT
INTERFACE.
7. FOR OPENING SCHEDULE, SEE SHEET AS702.
8. IN ROOMS LABELED "HSKPG" PROVIDE MOP STRIP OVER FLOOR
SINK AND SHELF ADJACENT TO MOP STRIP, SEE 14/AS401 TYP.
9. PROVIDE SHADES ON ROOM SIDE OF BORROWED LIGHT FRAMES
THROUGHOUT.
10. UNNUMBERED DOORS/OPENINGS ARE EXISTING TO REMAIN.
11. PROVIDE ACCESS PANELS IN GYP BD PARTITIONS AND CEILINGS
WHERE SERVICE ACCESS TO MECHANICAL AND ELECTRICAL
EQUIPMENT IS REQUIRED- SEE MECHANICAL AND ELECTRICAL FOR
LOCATIONS.
1. VERIFY CONDITIONS NOTED AS EXISTING. NOTIFY ARCHITECT IMMEDIATELY
OF ANY DISCREPANCIES.
2. REMOVE EXISTING CONSTRUCTION SHOWN DASHED AND AS NOTED, UNLESS
NOTED OTHERWISE. REMOVE ITEM OR ASSEMBLY IN ITS ENTIRETY INCLUDING
MOUNTING BRACKETS, HARDWARE, SUPPORTS AND OTHER APPURTENANCES.
SALVAGE AS NOTED OR DISPOSE OF PROPERLY.
3. PARTITIONS SHOWN TO BE REMOVED ARE WOOD PANELING, PLYWOOD OR
FIBER BOARD ON WOOD STUDS UNLESS NOTED OTHERWISE.
4. REMOVE DEBRIS, DIRT, DUST FROM EXISTING SURFACES THAT WILL
REMAIN EXPOSED AT THE COMPLETION OF WORK, OR TO PROPERLY ACCEPT
MATERIALS SPECIFIED UNDER THIS CONTRACT. ALSO SEE GENERAL CLEANING
NOTES ON SHEET GI002.
5. REMOVE MISCELLANEOUS FURRING, BRACKETS, FASTENERS, ETC. NO LONGER
IN USE FROM INTERIOR SURFACES THAT ARE SCHEDULED TO BE EXPOSED OR
RECEIVE FINISHES UNDER THIS CONTRACT.
F
F
F
F
F
F
F
F F
F
F
F
F
F
F
F
F
FS
F S
R
20 21 22 23
D
F
H
J
K
L
19.1
19.1
E
I
E X
IS
T
IN
G
E X
IT
P
A S
S A
G E
W A
Y
EXISTING
VESTIBULE
21.2 21.3
G
EXISTING VESTIBULE
ACT @
8'-0" AFF
AS601
L
IM
IT
O
F W
O R
K
LIMIT OF WORK
ACT @
8'-0" AFF
ACT @
8'-0" AFF
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
OFFICE
OFFICE
OPEN OFFICE
AS601
EXISTING
STAIR B
ACT
INSTALL AS TIGHT
AS POSSIBLE TO
UNDERSIDE OF
WOOD BEAM
ACT
INSTALL AS TIGHT
AS POSSIBLE TO
UNDERSIDE OF
WOOD BEAM
ELEC
CLOSET
144A
REFLECTED CEILING LEGEND
LOW PROFILE 1X4 LIGHT FIXTURE
DOWNLIGHT
SUPPLY DIFFUSER/RETURN REGISTER
EMERGENCY EXIT LIGHT FIXTURES
REFLECTED CEILING
GENERAL NOTES:
1. ACT IS ACT TYPE 1 - UNO
2. COORDINATE LOCATION OF EXIT SIGNS AS SHOWN ON
ENGINEERING DRAWINGS AND LIFE SAFETY SHEETS.
3. PROVIDE ACCESS PANELS WHERE INDICATED IN
SPECIFICATION.
F
INDUSTRIAL LED LIGHT FIXTURE
F SMOKE DETECTOR
HORN/STROBE FIRE ALARM
SURFACE MOUNTED LED VANITY/SCONCE
4' SURFACE MOUNT LED
EMERGENCY LIGHT FIXTURE
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:0 :2
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS105
REFLECTED CEILING PLAN -
LOWER LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
REFLECTED CEILING PLAN -
LOWER LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
10No. Revisions Date
FF
F
F
F
F
F
F
F
F
F
F
F
FF
F
FFFFF
F F F F F F
F
F S
FS
F S
F S
F S
F
R
F
F
21 22
D
F
H
J
K
L
19.1
E
I
EXISTING
ELECTRICAL
21.2 21.3
G
NO WORK
9.1 11.1 13.1 15.1 17.1
I.1
K.1
L.1
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
PASSAGE
EXPOSED
STRUCTURE- PAINT
EXISTING EXPOSED
STRUCTURE- PAINT
EXPOSED BEAMS
EXISTING EXPOSED BEAMS-
PAINT, TYPICAL
EXISTING METAL COVE AND
CEILING TO REMAIN. PAINT
EXISTING
BEAM WRAP - PAINT
ACT
INSTALL AS TIGHT
AS POSSIBLE TO
UNDERSIDE OF
WOOD BEAM
ACT
INSTALL AS TIGHT
AS POSSIBLE TO
UNDERSIDE OF
WOOD BEAM
INFILL AREA WITH GYP
BD (5/8" MIN) AND
WOOD LATH TO BE
FLUSH WITH
ADJACENT EXISTING
PLASTER CEILING
SURFACES
REINSTALL SALVAGED
METAL CEILING PANELS ON
WOOD SLEEPERS (TO MATCH
EXISTING INSTALLATION
METHOD) - PAINT
L
IM
IT
O
F W
O R
K
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONFERENCE
PASSAGE
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
PASSAGE
OPEN OFFICE
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
CONSULT
ROOM
MECH
TOILET
OFFICE
LIMIT OF WORK
ACT @
8'-6" AFF
ACT @
8'-6" AFF
ACT @
8'-6" AFF
/4
/2
AS601
GYP BD
SOFFIT
GYP BD
SOFFIT
AS601
INFILL AREA WITH GYP BD
(5/8" MIN) AND WOOD
LATH TO BE FLUSH WITH
ADJACENT EXISTING
PLASTER CEILING
SURFACES
EXISTING CEILING
TO REMAIN
EXISTING EXPOSED
STRUCTURE- PAINT
AS601
ALL AROUND
AS402
8'-0" ACCOUSTICAL BAFFLES
9" OC CENTERED
IN EACH ROOM
4'-0" ACCOUSTIC
BAFFLES 9" OC
CENTERED
8'-0" ACCOUSTICAL BAFFLES
9" OC CENTERED
IN EACH ROOM
BULKHEAD CENTERED
ON DEMOUNTABLE
PARTITION- BOTTOM OF
BULKHEAD @ 8'-6" AFF
REPLACE DAMAGED
METAL CEILING PANELS
WITH SALVAGED PANELS
FROM OTHER LOCATIONS
WHERE POSSIBLE
AS602
ELEC
CLOSET
244A
REFLECTED CEILING LEGEND
LOW PROFILE 1X4 LIGHT FIXTURE
DOWNLIGHT
SUPPLY DIFFUSER/RETURN REGISTER
EMERGENCY EXIT LIGHT FIXTURES
REFLECTED CEILING
GENERAL NOTES:
1. ACT IS ACT TYPE 1 - UNO
2. COORDINATE LOCATION OF EXIT SIGNS AS SHOWN ON
ENGINEERING DRAWINGS AND LIFE SAFETY SHEETS.
3. PROVIDE ACCESS PANELS WHERE INDICATED IN
SPECIFICATION.
F
INDUSTRIAL LED LIGHT FIXTURE
F SMOKE DETECTOR
HORN/STROBE FIRE ALARM
SURFACE MOUNTED LED VANITY/SCONCE
4' SURFACE MOUNT LED
EMERGENCY LIGHT FIXTURE
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:0 :2
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS106
REFLECTED CEILING PLAN -
MAIN LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
REFLECTED CEILING PLAN -
MAIN LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
11No. Revisions Date
F F
F
F
F
F
F
F
F
F
F
F
F
F
R
F
F
F
F SFS
F
F
R
F
20 21 22
D
F
H
J
K
L
19.1
19.1
E
I
21.2 21.3
G
ATTIC
309A
CONSULT
ROOM
CONFERENCE
P A
S S
A G
E
ACT @
8'-0" AFF
SLOPED GYP BD
PAINT
ACT @
8'-0"AFF
FLAT GYP BD
PAINT
8'-0" AFF
EXPOSED
STRUCTURE
ACT @
8'-0" AFF
EXPOSED
STRUCTURE
SLOPED GYP BD
PAINT
EXISTING
STAIR B
L
IM
IT
O
F W
O R
K
LIMIT OF WORK
MEN
WOMEN
HSKPG
303A
SLOPED GYP BD
PAINT
5/8" GYP
APPLIED TO
ROOF JOISTS
SLOPED GYP BD
PAINT
ATTIC
313A
SLOPED GYP
BD PAINT
CONSULT
ROOM
PASSAGE
CONSULT
ROOM
CONSULT
ROOM
FLAT GYP BD
PAINT
8'-0" AFF
FLAT GYP BD
PAINT
8'-0" AFF
CONSULT
ROOM
ATTIC
310A
EXIST GYP
CEILING TO
REMAIN - PAINT
AS402
AS402
REFLECTED CEILING LEGEND
LOW PROFILE 1X4 LIGHT FIXTURE
DOWNLIGHT
SUPPLY DIFFUSER/RETURN REGISTER
EMERGENCY EXIT LIGHT FIXTURES
REFLECTED CEILING
GENERAL NOTES:
1. ACT IS ACT TYPE 1 - UNO
2. COORDINATE LOCATION OF EXIT SIGNS AS SHOWN ON
ENGINEERING DRAWINGS AND LIFE SAFETY SHEETS.
3. PROVIDE ACCESS PANELS WHERE INDICATED IN
SPECIFICATION.
F
INDUSTRIAL LED LIGHT FIXTURE
F SMOKE DETECTOR
HORN/STROBE FIRE ALARM
SURFACE MOUNTED LED VANITY/SCONCE
4' SURFACE MOUNT LED
EMERGENCY LIGHT FIXTURE
CONSULTANTS: ARCHITECT/ENGINEERS: Drawing Title
Approved: Project Director Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Office of Construction and Facilities Management
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
AE PROJECT NO.: 14396
: 222
TO JT
KEY PLAN
07-21-2017
/2
/2
:0 :2
A
M C
U s e rs
\E P e te rs o n \D o c u m e n ts
\1 F o rt
S n e lli n g R
J T u c h te n h a g e n .r v t
1341-AS107
REFLECTED CEILING PLAN
-ATTIC LEVEL
BUILDING 222, BUILD OUT
PACKAGE
FORT SNELLING
07-21-2017
618-18-100
6330 BLOOMINGTON RD, ST. PAUL, MN 55111
100% CD ISSUE - BID DOCUMENTS
of 71
1/8" = 1'-0"
REFLECTED CEILING PLAN -
ATTIC LEVEL
PLAN
NORTH
TR
U E
N O R
TH
0 8' 16' 24'2' 4'
12No. Revisions Date
REF.
RAMP
1/12
FLOOR MOUNTED
HANDRAIL
PASSAGE
AS401
WALL MOUNTED
HANDRAIL
INFILL PLASTER
AT EXIST CMU
5' - 0"
D1
P3
P4
DN
/2
RAMP
6' - 0"
FFE= 7'-8 1/2"
FFE= 8'-2 1/2"
AS401
D
F
E
21.3
FEC
NIC
AS401 5
AS401 3
A
HSKPG
303A
MEN
WOMEN
8' - 2"
AS401
E Q
E Q
7' - 8 1/4"
CONFERENCE
P1A
P1A
P1A
PASSAGE
24"x36"
ACCESS PANEL
AS401
2' - 2"3' - 0"
APPLY 5/8" TYPE
'X' GYP BD OVER EXIST
WOOD FRAMING
WITHIN THIS SPACE.
EXIST
DRINKING
FOUNTAIN
L
21.317
AS401
1 1/2" OD FLOOR MOUNTED
METAL PIPE HANDRAIL,
PAINT
5…