36C26319B0005-0001009.pdf

PDF 222 KB Posted

Attached to
PN: 568A4-18-205, Correct Legionella Deficiencies (HS)
Solicitation number
36C26319B0005
Issued by

About this file

36C26319B0005 0001 S02_Attachment 9_M-Bldg12-ground - Mech-Model (1 Page).pdf

View the file

Other files

File Type Posted
36C26319C0185-000.docx DOCX document
36C26319B0005-0002000.docx DOCX document
36C26319B0005-0001002.pdf PDF
36C26319B0005-0001003.pdf PDF
36C26319B0005-0001006.pdf PDF
36C26319B0005-0001007.pdf PDF
36C26319B0005-0001005.pdf PDF
36C26319B0005-0001012.pdf PDF
36C26319B0005-0001000.docx DOCX document
36C26319B0005-0001008.pdf PDF
36C26319B0005-0001001.pdf PDF
36C26319B0005-0001010.pdf PDF
36C26319B0005-0001011.pdf PDF
36C26319B0005-0001013.pdf PDF
36C26319B0005-0001004.pdf PDF
36C26319B0005-0001014.docx DOCX document
36C26319B0005-001.docx DOCX document
36C26319B0005-007.pdf PDF
36C26319B0005-011.pdf PDF
36C26319B0005-012.pdf PDF
36C26319B0005-009.pdf PDF
36C26319B0005-010.pdf PDF
36C26319B0005-003.rtf RTF text file
36C26319B0005-008.pdf PDF
36C26319B0005-004.pdf PDF
36C26319B0005-002.docx DOCX document
36C26319B0005-006.pdf PDF
36C26319B0005-005.pdf PDF
36C26319B0005-000.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REFRIGERATOR

G1

VEGETABLE

PREPARATION

G2

REFRIGERATOR

G4

REFRIGERATOR

G3

KITCHEN

G5

G6

G7

G8

G9

G10

G11

G12

G13

FREEZER

G15

FREEZER

G14

STORAGE/

RECEIVING

G16

G18

G22

G23

REFRIGERATOR

G21

G20

G19

OFFICE

B016B

OFFICE

B016A

DIETETIC

OFFICE

B016

DIETETIC CHIEF

OFFICE

B017

NUC.

MED

B011B

STORAGE

B014

B014A

OFFICE

B010B

STORAGE

B012

B010

OFFICE

B010A

OFFICE

B008B

WAITING

ROOM

B008

MECHANICAL

ROOM

B008A

TOILET

OFFICE/

FILES

B011

OFFICE

B011A

CONSULT

B009B

HOT LAB

B009A

IMAGE ROOM

NUC MED

B007

X-RAY

ROOM

B006

X-RAY

ROOM

B002

DARKROOM

WORKROOM

B004

TOILET

B002A

RADIOLOGY

OFFICE

C004

MECHANICAL

ROOM

B005A

MENS

TOILET

B005

WOMENS

TOILET

B003

RADIOLOGY

STORAGE

B001

TELEPHONE

MECHANICAL

ROOM

C003

ULTRASOUND

C002

FIRE

VALVE

G25A

EXAM

ROOM

C001B

EXAM

ROOM

C001

EXAM

ROOM

C001A

CHEMO

C012

HEALTH BENEFITS

ASSISTANCE OFFICE

C011

HBA

C010

HEALTH BENEFITS

ASSISTANCE OFFICE

C009

HEALTH BENEFITS

ASSISTANCE

C008

WAITING TELEPHONE

TELEHEALTH

A002

WAIT

A001

CASHIER

A003

STORAGE

EYE

TELEMETRY

A005

A007

A009

WOMENS

EXAM

A011

PHARMACY

A013

EXAM

A015

EXAM

A017

EXAM

A019

EXAM

A021

EXAM

A023

EMPLOYEE

HEALTH

A025

TELE-TRIAGE

OFFICE

A027

EXAM

A030

EXAM

A032

ANTE

EXAM

A026

EXAM

A028

EXAM

A022

EXAM

A024

EXAM

A018

TREATMENT

A020

CART

A012

TOILET TOILET

URGENT

CARE

A042

NURSES

STATION

A034

ELEC.

A030

TELE.

SOILED

UTILITY

A044

CLEAN

UTILITY

A040A

URGENT

EXAM

A040

TRIAGE

ROOM

A048

EKG-PFT

A043

RECEPT

WAIT

WORKROOM

A031

STORAGE/

WORKROOM

A029

EXAM

A035

EXAM

A037

EXAM

A039

ELEC.

NURSE

CALL

A008

RECEPT

WAITING

MENS

TOILET

WOMENS

TOILET

RELEASE

OF INFO

D004

RELEASE

OF INFO

D002

STORAGE

D006

PSYCHOLOGIST

OFFICE

D008

RURAL HEALTH

STORAGE

MECHANICAL

STORAGE

D010

PHARMACY

BREAKROOM

D012

PHARMACY

D016

D014

VAULT

D016A

IV HOOD

D016B

D016C

COUNSELING

D012A

PHARMACY

OFFICE

D018

PHARMACY

UNIT DOSE

D019

PHARMACY

OFFICE

D017

PHARMACY

WAITING

D015

TOILET

D013

PHARMACY

OFFICE

D009

HAC

D011

PHARMACY

OFFICE

D007

CASE MANAGEMENT

OFFICE

D005

REF.

CASE

D003B

REF.

CASE

D003A

D003

STAFF

BREAKROOM

D001

A

H

U

A

H

U

DCW UP & DN

CHASE

1" DHW UP TO

D110 (ABANDONED)

2" DCW HARD & 1" DHW UP & DN

" DCW HARD & 1" DHW UP & DN

ABANDON

" DCW & DHW IN

WALL & DN TO DB03

LPS & CR UP & DN

" UP TO

D118 SINK

" UP TO LAVS

IN D107

PLAN NOTES:

COULD NOT VERIFY UTILITY ROUTING DUE TO HARD CEILINGS,

PIPING IN WALLS, OR INACCESSIBLE AREAS. ANY UTILITY

PIPING SHOWN ON PLAN IN THIS GENERAL AREA IS AN

ASSUMPTION OR ESTIMATION.

PIPING THOUGHT TO BE CONTAINED IN WALL. SHOWN HERE

OUTSIDE WALL FOR CLARITY.

DID NOT VERIFY UTILITY ROUTING OR TERMINATION POINT.

PIPES UP FROM

BASMENT TO FIRST

LPS & CR UP TO

D109 FIN TUBE

2" DCW & 1" DHW

UP TO RM C101

" DCW & DHW

UP TO C101A LAV

1" DCW UP TO

C101A TOILET

2" &

" DCW, 1" &

" DHW DN

TO BASEMENT CRAWLSPACE

1" DCW & 1/2" DHW DN TO CRAWL SPACE

1"

" UP TO

D118A SINK

" UP TO

D116 SINK

" UP TO D118A MIXING

VALVE (ABANDONED)

" UP TO D112

WALL (ABANDONED)

" UP TO D112 SINK

" UP TO D112E

& D112D SINKS

" UP TO D116

& D112E SINKS

" UP TO D112D

& D112C SINKS

" DCW SOFT UP TO

D112E (ABANDONED)

" DCW SOFT UP TO

D112C (ABANDONED)

" DCW SOFT UP TO

D112B (ABANDONED)

" UP TO 112B

& 112C SINKS

" UP TO 112B SINK &

ABANDONED

" DCW UP

" UP TO D112A SINK

1" DCW HARD &

" DHW

UP & DN (ABANDONED)

" DCW HARD,

" DHW, AND

ABANDONED

" DHW DN TO DB03

" DCW SOFT &

" DHW UP & DN

" DCW TO WC

" DCW SOFT,

" DHW,

& 1" DCW HARD UP & DN

1"

1"

" DCW & DHW UP

TO 102 SINK

DCW & DHW UP

AND DOWN IN

CHASE

" DCW & DHW DN TO BASEMENT CRAWLSPACE

" DCW TERMINATION

POINT UNKNOWN

" DCW & DHW DN

TO DB07 (ABANDONED)

" DOMESTIC (ABANDONED)

1" DCW SOFT,

" DHWR,

& 1" DHW UP & DN

LPS & CR UP & DN

LPS & CR UP & DN

1" MPS,

" DHWR, 2"

DHW & DCW UP & DN

1" DCW &

" DHW

UP TO B108 CHASE

2" DCW & 1" DHW

UP TO B104 CHASE

2"

2" DCW & 1" DHW

UP TO C100

2" DCW & 1" DHW

DN TO BASEMENT

CRAWLSPACE

PLAN NOTES:

COULD NOT VERIFY UTILITY ROUTING DUE TO HARD CEILINGS,

PIPING IN WALLS, OR INACCESSIBLE AREAS. ANY UTILITY

PIPING SHOWN ON PLAN IN THIS GENERAL AREA IS AN

ASSUMPTION OR ESTIMATION.

PIPING THOUGHT TO BE CONTAINED IN WALL. SHOWN HERE

OUTSIDE WALL FOR CLARITY.

DID NOT VERIFY UTILITY ROUTING OR TERMINATION POINT.

ABANDONED

ABANDONED

DOMESTIC DN

TO BASEMENT

CRAWLSPACE

erase erase

2" DCW &

" DHW DN TO

BASEMENT CRAWLSPACE

2" DCW &

" DHW DN TO

BASEMENT CRAWLSPACE

2" DCW, 1" DHW, &

" DHWR

UP TO 2ND FLR CHASE

2" DCW, 2" DHW, &

DHWR DN TO MECH RM

2" DCW, 2" DHW,

" DHWR UP

TO A110A WALL

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DOWN

AutoCAD SHX Text Riser 2

AutoCAD SHX Text Riser 4

AutoCAD SHX Text Riser 3

AutoCAD SHX Text Riser 5

AutoCAD SHX Text Riser 6

AutoCAD SHX Text Riser 8

AutoCAD SHX Text Riser 9

AutoCAD SHX Text Riser 12

AutoCAD SHX Text Riser 11

AutoCAD SHX Text Riser 20

AutoCAD SHX Text Riser 16

AutoCAD SHX Text Riser 13

AutoCAD SHX Text Riser 14

AutoCAD SHX Text Riser 18

AutoCAD SHX Text Riser 15

AutoCAD SHX Text Riser 19

AutoCAD SHX Text Riser 22

AutoCAD SHX Text Riser 23

AutoCAD SHX Text Riser 24

AutoCAD SHX Text Ground Floor

AutoCAD SHX Text Riser 7

AutoCAD SHX Text Riser 10 pipe chase with isolation valves

AutoCAD SHX Text Riser 21 Pipe chase, isolation valves near

AutoCAD SHX Text Riser 1 pipe chase with isolation valves

AutoCAD SHX Text Riser 17 Pipe chase, isolation valves near

Sheets and Views
Model

File details come from the government source that posted it.