The report encompasses comprehensive environmental and equipment testing across multiple rooms within the pharmacy facility. Testing includes certification of Biological Safety Cabinets (BSCs), unidirectional flow devices (clean benches), cleanroom certification, airborne nonviable particle count testing, viable sample collection, and pressurization data validation. Specific areas tested include the Hazardous Sterile Ante Room (ISO-7), Hazardous Sterile Buffer Room (ISO-7), Hazardous Storage Room, and Non-Hazardous Sterile Buffer Room (ISO-7). All tested BSCs achieved ISO-5 certification with passing results for airflow velocity, HEPA leak tests, and aerosol concentration measurements. Clean benches passed certification with measured outflow velocities of 89-94 FPM. Cleanroom testing confirmed compliance with applicable standards including USP <797>, USP <800>, CETA CAG-003, and IEST standards, with airborne particle counts well below ISO-7 and ISO-5 class limits. Viable sampling was conducted with 15 active air samples and 20 surface samples collected from various cleanroom locations. All pressurization tests passed, confirming proper directional airflow between adjacent areas. Equipment calibration records confirm use of NIST-traceable instruments with current calibration dates. The retest date is scheduled for March 2027.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TH T3 Building 24 Pharmacy Testing Sept 2026 AL
Technical Safety Services Corporate Headquarters 4225 Executive Square, Suite 370 La Jolla, CA 92037 800.877.7742 www.techsafety.com
Project Site:
VA Fresno
2615 East Clinton Avenue
Fresno, CA 93703
Project Contact:
Travis Horn
2615 East Clinton Avenue
Fresno CA, 93703
Travis.Horn@va.gov
4225 Executive Square, Suite 370
La Jolla, CA 92037
(800) 877-7742
Pharmacy Summary Report
Project: NC-VFR2627401A-1 TH T3 Building 24 Pharmacy Testing Sept 2026 AL
Site: VA Fresno 2615 East Clinton Avenue Fresno, CA 93703
Contact: Travis Horn
(559) 225-6100 Travis.Horn@va.gov
Technician: Daniel Velazquez
Qualifications:
TSS Technicians are trained and competent in the methods and procedures in CETA CAG-003
Purpose:
This document serves as the preliminary report summary of testing performed at your facility on the date(s) listed. These tests were conducted to demonstrate compliance with USP <797>, CETA and applicable TSS SOPs and is subject to further review.
Summary of Test Results:
Below is a list of the services performed at your facility on the given test date(s). Where applicable, test results have been applied to the listed tasks. If results are pending, such as airborne and surface viable testing that requires post-test incubation and enumeration laboratory processing, these results will be sent to the client contact separately on a future date.
This document along with the attached field documentation can serve your auditing and internal assessment needs. If you require anything further, please contact TSS at (800) 877-7742.
NC-VFR2627401A-1 / September 11, 2026 1 of 3
Test Report Summary Table
Serial Number Cert. ID Test Description Unit Type
ISO
Class
Cert. Date Result
199716071620 DV2691010465 Certification A2 ISO-5 09/10/2026 Certification: Certified
199716071620 DV269109821 Non Viable Sample A2 ISO-5 09/10/2026 Non Viable Sample: Pass
199716071620 DV26910973 Special Project A2 ISO-5 09/10/2026 Airflow Visualization Study: Complete
199733071720 DV26910104620 Certification A2 ISO-5 09/10/2026 Certification: Certified
199733071720 DV269109845 Non Viable Sample A2 ISO-5 09/10/2026 Non Viable Sample: Pass
199733071720 DV269109643 Special Project A2 ISO-5 09/10/2026 Airflow Visualization Study: Complete
199746071720 DV26910104641 Certification Clean Bench ISO-5 09/10/2026 Certification: Certified
199746071720 DV26910103727 Non Viable Sample Clean Bench ISO-5 09/10/2026 Non Viable Sample: Pass
199746071720 DV269109753 Special Project Clean Bench ISO-5 09/10/2026 Airflow Visualization Study: Complete
199751071720 DV26910104632 Certification Clean Bench ISO-5 09/10/2026 Certification: Certified
199751071720 DV26910103620 Non Viable Sample Clean Bench ISO-5 09/10/2026 Non Viable Sample: Pass
199751071720 DV269109722 Special Project Clean Bench ISO-5 09/10/2026 Airflow Visualization Study: Complete
Building 24 Sterile Compounding Sui
DV26910964 Viable Sample Environmenta l Sampling Unit
NA 09/10/2026 Viable Samples (35): Sampled
Hazardous Sterile Ante Room
DV26910104810 Certification HD Sterile Anteroom
ISO-7 09/10/2026
Airflow: FIO HEPA Leak Test: Pass Room Air Exchange Rate: Pass Room Pressures: Pass Non-Viable Sample: Pass
Hazardous Sterile Buffer Room
DV26910104837 Certification HD Sterile Buffer Room
ISO-7 09/10/2026
Airflow: FIO HEPA Leak Test: Pass Room Air Exchange Rate: Pass Room Pressures: Pass Non-Viable Sample: Pass
Hazardous Storage Room
DV26910104915 Certification HD Storage NA 09/10/2026 Airflow: FIO Room Air Exchange Rate: Pass Room Pressures: Pass
Non-Hazardous Sterile Buffer Room
DV26910104742 Certification Non-HD Sterile Buffer Room
ISO-7 09/10/2026
Airflow: FIO HEPA Leak Test: Pass Room Air Exchange Rate: Pass Room Air Exchange Rate + PEC: Pass Room Pressures: Pass Non-Viable Sample: Pass
Definitions / Acronyms
ACPH Air changes per hour
BSC Biological Safety Cabinet
CAI Compounding Aseptic Isolator
CACI Compounding Aseptic Containment Isolator
CETA Controlled Environment Testing Association
CER Controlled Environment
CFM Cubic Feet per Minute (air volume measurement)
CSP Compounded Sterile Preparation
DCA Direct Compounding Area
FPM Feet per Minute (air velocity measurement)
HEPA High Efficiency Particulate Air (filter)
NC-VFR2627401A-1 / September 11, 2026 2 of 3
HVAC Heating Ventilation and Air Conditioning
IEST Institute for Environmental Sciences and Technology
ISO International Organization for Standardization
LAFW Laminar Air Flow Workstation
NSF/ANSI NSF International/ American National Standards Institute
PEC Primary Engineering Control (ISO5 Environment, e.g., BSC, LAFW, CAI, CACI)
RAER Room Air Exchange Rate (ACPH)
SCA Segregated Compounding Area
SEC Secondary Engineering Control (Cleanroom)
TAF Terminal Air Filter (Ceiling/Room Side HEPA Filter)
UAV Unidirectional Airflow Visualization um Micrometer 1 x 10-6 meters (particle size measurement)
VLF Vertical Laminar Flow
WC Water Column (pressure measurement)
NC-VFR2627401A-1 / September 11, 2026 3 of 3
Biological Safety Cabinet Certification Report
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2691010465 Facility: VA Fresno ID: 5505820 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199716071620Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
Test Standard(s): MANUFACTURER, OSHA, ANSI/NSF 49, USP <797>, CETA CAG-003
Inspected Min Max Measured Result
Calculated Inflow Velocity (FPM) 100 110 105 Pass
Average Supply Velocity Zone1 (FPM) 55 65 60 Pass
Average Supply Velocity Zone2 (FPM) NA NA NA NA
Average Supply Velocity Zone3 (FPM) NA NA NA NA
Average Supply Velocity Zone4 (FPM) NA NA NA NA
Supply Uniformity NA NA Pass Pass
Downflow Smoke Pattern Test NA NA Pass Pass
View Screen Retention Smoke Pattern Test NA NA Pass Pass
Work Opening Edge Retention Smoke Pattern Test NA NA Pass Pass
Sash Seal Smoke Pattern Test NA NA Pass Pass
Site Assessment NA NA Pass Pass
At-Rest Unidirectional Airflow Visualization Test NA NA NA NA
Dynamic Unidirectional Airflow Visualization Test NA NA Pass Pass
Supply Delta Pressure ("W.C.) NA NA NA NA
Duct Pressure ("W.C.) NA NA NA NA
Supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 23 Pass
Exhaust Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 23 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:33 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 1/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2691010465 Facility: VA Fresno ID: 5505820 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199716071620Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
Inflow (FPM) Method: MFR spec: I4 - Constricted Access Calculated Inflow Velocity (FPM): 105
Workface: Width: 46.50" Height: 10.00" Workface Area (ft²): 3.23
Adj. Workface: Width: 46.50" Height: 3.00" Adj. Workface Area (ft²): 0.97
AK Factor: 1.00 Inflow Factor: 0 Volume (CFM): 340
Readings:
344 347 352 365 349 351 345 354
Supply (FPM) Method: MFR spec: S1 - Unidirectional (non-zoned) flow Average Supply Velocity(FPM): 60
Dimensions: Width: 46.50" Depth: 25.00" Supply Area (ft²): 8.07
Readings:
Supply Volume (CFM): 484
66 64 66 64 65 64 63
61 60 60 59 58 57 57
60 58 58 53 55 55 58
Site Assessment:
Exhaust System: Canopy: Negative: The Canopy Passed the performance test.
Exhaust System Alarm: Pass: The Exhaust System Alarm Passed the performance test.
Sash Alarm: Pass: The Sash Alarm Passed the performance test.
Interlock: NA: No Interlock Alarm present.
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:33 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 2/2
(800) 877-7742
Cert. No.: DV269109821 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-540-400
Address: 2615 East Clinton Avenue Room: HD Sterile Buffer Room Unit Type: A2
Fresno, CA 93703 Contact: Travis Horn SN: 199716071620
Airborne Nonviable Particle Count Test Report Clean Zone: 199716071620 Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-5 Area: 8.07 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 0 NA NA 0 Pass
T. C° % rH
21.1 54
Class Limit: 3,520 21.1 54
Sample Volume Test: Pass
Class Limit Location Test: Pass
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
This record was electronically signed by:
Page: 1/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:38:10 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate representation of work performed.
Print Date: 09/10/2026
(800) 877-7742
Cert. No.: DV269109821 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-540-400
Address: 2615 East Clinton Avenue Room: HD Sterile Buffer Room Unit Type: A2
Fresno, CA 93703 Contact: Travis Horn SN: 199716071620
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
013812 Govee H5075 EQ13812 10/2026
009464 Climet CI-750t 057234 11/2026 www.techsafety.com
This record was electronically signed by:
Page: 2/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:38:10 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
Airflow Visualization Study
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910973 Facility: VA Fresno ID: 5505820 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199716071620Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
Service Type: Airflow Visualization Study
Comments: (Dynamic) Tracer moves in a unidirectional manner without reflux. Actions of the personnel do not affect the general trajectory of tracer.
Doc. Title Doc. # Doc. Version Completed Date Originally Retained By
Diagram NA NA 09/10/2026 Daniel Velazquez www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:07 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910973 Facility: VA Fresno ID: 5505820 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199716071620Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:07 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 2/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910104620 Facility: VA Fresno ID: 5505819 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199733071720Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
Test Standard(s): MANUFACTURER, OSHA, ANSI/NSF 49, USP <797>, CETA CAG-003
Inspected Min Max Measured Result
Calculated Inflow Velocity (FPM) 100 110 103 Pass
Average Supply Velocity Zone1 (FPM) 55 65 64 Pass
Average Supply Velocity Zone2 (FPM) NA NA NA NA
Average Supply Velocity Zone3 (FPM) NA NA NA NA
Average Supply Velocity Zone4 (FPM) NA NA NA NA
Supply Uniformity NA NA Pass Pass
Downflow Smoke Pattern Test NA NA Pass Pass
View Screen Retention Smoke Pattern Test NA NA Pass Pass
Work Opening Edge Retention Smoke Pattern Test NA NA Pass Pass
Sash Seal Smoke Pattern Test NA NA Pass Pass
Site Assessment NA NA Pass Pass
At-Rest Unidirectional Airflow Visualization Test NA NA NA NA
Dynamic Unidirectional Airflow Visualization Test NA NA Pass Pass
Supply Delta Pressure ("W.C.) NA NA NA NA
Duct Pressure ("W.C.) NA NA NA NA
Supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 22 Pass
Exhaust Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 22 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:36 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910104620 Facility: VA Fresno ID: 5505819 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199733071720Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
Inflow (FPM) Method: MFR spec: I4 - Constricted Access Calculated Inflow Velocity (FPM): 103
Workface: Width: 46.50" Height: 10.00" Workface Area (ft²): 3.23
Adj. Workface: Width: 46.50" Height: 3.00" Adj. Workface Area (ft²): 0.97
AK Factor: 1.00 Inflow Factor: 0 Volume (CFM): 332
Readings:
351 348 344 337 331 336 342 347
Supply (FPM) Method: MFR spec: S1 - Unidirectional (non-zoned) flow Average Supply Velocity(FPM): 64
Dimensions: Width: 46.50" Depth: 25.00" Supply Area (ft²): 8.07
Readings:
Supply Volume (CFM): 516
66 67 67 64 64 65 66
67 63 63 63 64 62 65
63 61 63 62 61 63 64
Site Assessment:
Exhaust System: Canopy: Negative: The Canopy Passed the performance test.
Exhaust System Alarm: Pass: The Exhaust System Alarm Passed the performance test.
Sash Alarm: Pass: The Sash Alarm Passed the performance test.
Interlock: NA: No Interlock Alarm present.
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:36 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 2/2
(800) 877-7742
Cert. No.: DV269109845 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-540-400
Address: 2615 East Clinton Avenue Room: HD Sterile Buffer Room Unit Type: A2
Fresno, CA 93703 Contact: Travis Horn SN: 199733071720
Airborne Nonviable Particle Count Test Report Clean Zone: 199733071720 Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-5 Area: 8.07 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 0 NA NA 0 Pass
T. C° % rH
21.0 55
Class Limit: 3,520 21.0 55
Sample Volume Test: Pass
Class Limit Location Test: Pass
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
This record was electronically signed by:
Page: 1/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:38:24 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
(800) 877-7742
Cert. No.: DV269109845 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-540-400
Address: 2615 East Clinton Avenue Room: HD Sterile Buffer Room Unit Type: A2
Fresno, CA 93703 Contact: Travis Horn SN: 199733071720
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
013812 Govee H5075 EQ13812 10/2026
009464 Climet CI-750t 057234 11/2026 www.techsafety.com
This record was electronically signed by:
Page: 2/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:38:24 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
La Jolla, CA 92037
(800) 877-7742
Cert.: DV269109643 Facility: VA Fresno ID: 5505819 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199733071720Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
Service Type: Airflow Visualization Study
Comments: (Dynamic) Tracer moves in a unidirectional manner without reflux. Actions of the personnel do not affect the general trajectory of tracer.
Doc. Title Doc. # Doc. Version Completed Date Originally Retained By
Diagram NA NA 09/10/2026 Daniel Velazquez www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:06 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV269109643 Facility: VA Fresno ID: 5505819 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-540-400
Phone: (559) 225-6100 Ext.5735 24 SN: 199733071720Bld:
Email: Travis.Horn@va.gov HD Sterile Buffer Room Class: II Type: A2Rm:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:06 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 2/2
Unidirectional Flow Device Certification Report
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910104641 Facility: VA Fresno ID: 5505818 Cust ID: Hood #2
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199746071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
Test Standard(s): USP <797>, CETA CAG-003, IEST-RP-CC002.4, USP <797> 2023, MANUFACTURER
Results
Inspected Min Max Measured Results
Outflow Velocity (FPM) 80 100 89 Pass
%RSD NA 15 5 Pass
Supply Delta Pressure ("W.C.) NA NA NA NA
Duct Pressure ("W.C.) NA NA NA NA
Backstreaming Test NA NA Pass Pass
Induction Leak Test NA NA Pass Pass
Smoke Source Glycerin and/or Glycol
Fluorescent Lighting (FC) NA NA NA NA
NAUltraviolet Lighting (μW/cm²) NA NA NA
NANoise Level (dBA) NA NA NA
NAVibration (in. RMS) NA NA NA
NAElectrical Current Leakage Test (mA) NA NA NA
NAElectrical Ground Resistance Test (Ohms) NA NA NA
NAElectrical Polarity NA NA NA
NAElectrical GCFI NA NA NA
Supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 20 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:40 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910104641 Facility: VA Fresno ID: 5505818 Cust ID: Hood #2
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199746071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
Velocity (FPM) Dimension: Width: 48.00" Height: 32.00" Average Velocity (FPM) 89
Area (ft²): 10.67
Readings: Volume (CFM): 950
79 84 87 89
88 90 86 89
95 96 92 88
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:40 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 2/2
(800) 877-7742
Cert. No.: DV26910103727 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-240-430
Address: 2615 East Clinton Avenue Room: Non-HD Sterile Buffer Room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 199746071720
Airborne Nonviable Particle Count Test Report Clean Zone: 199746071720 Status: Operational/Dynamic Cust ID: Hood #2 Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-5 Area: 10.67 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 0 NA NA 0 Pass
T. C° % rH
21.1 55
Class Limit: 3,520 21.1 55
Sample Volume Test: Pass
Class Limit Location Test: Pass
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
This record was electronically signed by:
Page: 1/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:37:53 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
(800) 877-7742
Cert. No.: DV26910103727 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-240-430
Address: 2615 East Clinton Avenue Room: Non-HD Sterile Buffer Room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 199746071720
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
013812 Govee H5075 EQ13812 10/2026
009464 Climet CI-750t 057234 11/2026 www.techsafety.com
This record was electronically signed by:
Page: 2/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:37:53 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
La Jolla, CA 92037
(800) 877-7742
Cert.: DV269109753 Facility: VA Fresno ID: 5505818 Cust ID: Hood #2
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199746071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
Service Type: Airflow Visualization Study
Comments: (Dynamic) Tracer moves in a unidirectional manner without reflux. Actions of the personnel do not affect the general trajectory of tracer.
Doc. Title Doc. # Doc. Version Completed Date Originally Retained By
Diagram NA NA 09/10/2026 Daniel Velazquez www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:08 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV269109753 Facility: VA Fresno ID: 5505818 Cust ID: Hood #2
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199746071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:08 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 2/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910104632 Facility: VA Fresno ID: 5505817 Cust ID: Hood #1
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199751071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
Test Standard(s): IEST-RP-CC002.4, CETA CAG-003, USP <797> 2023, MANUFACTURER, USP <797>
Results
Inspected Min Max Measured Results
Outflow Velocity (FPM) 80 100 94 Pass
%RSD NA 15 8 Pass
Supply Delta Pressure ("W.C.) NA NA NA NA
Duct Pressure ("W.C.) NA NA NA NA
Backstreaming Test NA NA Pass Pass
Induction Leak Test NA NA Pass Pass
Smoke Source Glycerin and/or Glycol
Fluorescent Lighting (FC) NA NA NA NA
NAUltraviolet Lighting (μW/cm²) NA NA NA
NANoise Level (dBA) NA NA NA
NAVibration (in. RMS) NA NA NA
NAElectrical Current Leakage Test (mA) NA NA NA
NAElectrical Ground Resistance Test (Ohms) NA NA NA
NAElectrical Polarity NA NA NA
NAElectrical GCFI NA NA NA
Supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 19 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:38 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV26910104632 Facility: VA Fresno ID: 5505817 Cust ID: Hood #1
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199751071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
Velocity (FPM) Dimension: Width: 48.00" Height: 32.00" Average Velocity (FPM) 94
Area (ft²): 10.67
Readings: Volume (CFM): 1,003
90 90 83 88
90 97 103 97
87 92 101 106
Report Date: 09/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 03/2027 eData: v8.0.3.1 Daniel Velazquez 09/10/2026 12:38 PM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/2026 Page: 2/2
(800) 877-7742
Cert. No.: DV26910103620 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-240-430
Address: 2615 East Clinton Avenue Room: Non-HD Sterile Buffer Room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 199751071720
Airborne Nonviable Particle Count Test Report Clean Zone: 199751071720 Status: Operational/Dynamic Cust ID: Hood #1 Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-5 Area: 10.67 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 0 NA NA 0 Pass
T. C° % rH
21.0 56
Class Limit: 3,520 21.0 56
Sample Volume Test: Pass
Class Limit Location Test: Pass
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
This record was electronically signed by:
Page: 1/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:36:52 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
(800) 877-7742
Cert. No.: DV26910103620 Svc. Order: NC-VFR2627401A-1 Make: NUAIRE
Facility: VA Fresno Building: 24 Model: NU-240-430
Address: 2615 East Clinton Avenue Room: Non-HD Sterile Buffer Room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 199751071720
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
013812 Govee H5075 EQ13812 10/2026
009464 Climet CI-750t 057234 11/2026 www.techsafety.com
This record was electronically signed by:
Page: 2/2 web: www.techsafety.com Daniel Velazquez 9/10/2026 10:36:52 AM eData v8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
La Jolla, CA 92037
(800) 877-7742
Cert.: DV269109722 Facility: VA Fresno ID: 5505817 Cust ID: Hood #1
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199751071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
Service Type: Airflow Visualization Study
Comments: (Dynamic) Tracer moves in a unidirectional manner without reflux. Actions of the personnel do not affect the general trajectory of tracer.
Doc. Title Doc. # Doc. Version Completed Date Originally Retained By
Diagram NA NA 09/10/2026 Daniel Velazquez www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:07 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 1/2
La Jolla, CA 92037
(800) 877-7742
Cert.: DV269109722 Facility: VA Fresno ID: 5505817 Cust ID: Hood #1
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NUAIRE
Contact: Travis Horn Fresno, CA 93703 Model: NU-240-430
Phone: (559) 225-6100 Ext.5735 24 SN: 199751071720Bld:
Email: Travis.Horn@va.gov Non-HD Sterile Buffer Room Class: NA Type: Clean BenchRm:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: NA eData v8.0.3.1 Daniel Velazquez 09/10/2026 09:07 AM
Print Version: Service Manager v8.0.3.1 Field Service Technician
Print Date: 09/10/2026 Page: 2/2
Viable Sample Report
La Jolla, CA 92037
800.877.7742
Cert.: DV26910964 Facility: VA Fresno ID: 5507045 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 24 SN: Building 24 Sterile Compounding Suite
Email: Travis.Horn@va.gov Rm: Building 24 Sterile Compoundi Class: NA Type: Environmental Sampling
Area Status: Operational/Dynamic
Occupants: TSS: 1 Client: 2
15 - Active Air Samples
Sample ID Location Type
Sample Size Media Lot # Exp. Date
A-01 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-02 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-03 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-04 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-05 ISO-7 1000 Liters TSA Settling Plate 691307P 01/2027
A-06 ISO-7 1000 Liters TSA Settling Plate 691307P 01/2027
A-07 ISO-7 1000 Liters TSA Settling Plate 691307P 01/2027
A-08 ISO-7 1000 Liters TSA Settling Plate 691307P 01/2027
A-09 ISO-7 1000 Liters TSA Settling Plate 691307P 01/2027
A-10 ISO-7 1000 Liters TSA Settling Plate 691307P 01/2027
A-11 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-12 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-13 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
A-14 ISO-5 1000 Liters TSA Settling Plate 691307P 01/2027
Control NA NA TSA Settling Plate 691307P 01/2027
20 - Surface Samples
Sample ID Location Type
Sample Size Media Lot # Exp. Date
Control NA NA TSA Contact Plate 688281P 11/2026
S-01 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-02 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-03 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-04 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-05 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-06 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-07 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-08 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-09 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-10 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026 www.techsafety.com
09/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 09/10/2026 10:35 AM eData: v 8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
Print Date: 09/2026 Page: 1/4
La Jolla, CA 92037
800.877.7742
Cert.: DV26910964 Facility: VA Fresno ID: 5507045 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 24 SN: Building 24 Sterile Compounding Suite
Email: Travis.Horn@va.gov Rm: Building 24 Sterile Compoundi Class: NA Type: Environmental Sampling
20 - Surface Samples
Sample ID Location Type
Sample Size Media Lot # Exp. Date
S-11 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-12 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-13 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-14 ISO-5 1 Plate TSA Contact Plate 688281P 11/2026
S-15 CNC 1 Plate TSA Contact Plate 688281P 11/2026
S-16 CNC 1 Plate TSA Contact Plate 688281P 11/2026
S-17 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-18 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
S-19 ISO-7 1 Plate TSA Contact Plate 688281P 11/2026
Remarks: NA www.techsafety.com
09/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 09/10/2026 10:35 AM eData: v 8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
Print Date: 09/2026 Page: 2/4
La Jolla, CA 92037
800.877.7742
Cert.: DV26910964 Facility: VA Fresno ID: 5507045 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 24 SN: Building 24 Sterile Compounding Suite
Email: Travis.Horn@va.gov Rm: Building 24 Sterile Compoundi Class: NA Type: Environmental Sampling www.techsafety.com
09/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 09/10/2026 10:35 AM eData: v 8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
Print Date: 09/2026 Page: 3/4
La Jolla, CA 92037
800.877.7742
Cert.: DV26910964 Facility: VA Fresno ID: 5507045 Cust ID: NA
SO: NC-VFR2627401A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 24 SN: Building 24 Sterile Compounding Suite
Email: Travis.Horn@va.gov Rm: Building 24 Sterile Compoundi Class: NA Type: Environmental Sampling
The following NIST-Traceable equipment were used to collect these viable samples:
Equipment ID Manufacturer Model Serial # Calibration Due
012632 AP BUCK B30120 C103665 10/24/2026
012638 AP BUCK B30120 C103671 10/24/2026
www.techsafety.com
09/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 09/10/2026 10:35 AM eData: v 8.0.3.1
Field Service Technician Print Version: Service Manager v8.0.3.1
I certify that this record is a true and accurate
Print Date: 09/2026 Page: 4/4
(800) 877-7742
Test Report
General Information:
Project Site: VA Fresno
2615 East Clinton Avenue
Fresno, CA 93703
Room: Hazardous Sterile Ante Room
Test Report ID: DV26910104810
Project ID: NC-VFR2627401A-1
Project Contact: Travis Horn
VFR01 | VA Fresno
(559) 225-6100
Travis.Horn@va.gov
Project Lead Tech: Daniel Velazquez
823 Kifer Rd
Sunnyvale, CA 94086 tel: (800) 877-7742 fax: (510) 845-5595
Project Description: TH T3 Building 24 Pharmacy Testing Sept 2026 AL
Technician Remarks: NA
Test Standards: CETA CAG-003, USP <800>, IEST-RP-CC006 www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 1/9 I certify that this record is a true and accurate
FIO: For Information Only NA: Not Applicable
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
Room Description:
Building: 24
Room: Hazardous Sterile Ante Room
Room Size:
Area (ft²): 227.26 Volume (ft³): 1,931
Area (m²): 21.11 Volume (m³): 55
Room Design:
ISO-7
Results
Inspected Min Max Measured Results
Airflow Volume (CFM) NA NA 1,281 FIO
Grand Mean (FPM) NA NA NA NA
Airflow Uniformity (%RSD) NA NA NA NA
Average Velocities (FPM) * * * FIO
Individual Unit Uniformity (%RSD) * * * NA
Leak Test (%) * * * Pass
Patch (% of Filter Area) * * * Pass
Room Air Exchange Rate (AC/H) 30 NA 40 Pass
Airborne Nonviable Particle Count * * * Pass
Differential Pressure * * * Pass
* Footnote – Results are aggregate of all units tested; individual unit criterion noted in the following pages.
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 2/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
TAF AIRFLOW MEASUREMENTS: Hazardous Sterile Ante Room
Filter ID Individual Measurements Lower Limit
Upper Limit
Avg Vel (fpm)
Area (ft²)
Kv Avg Vol (cfm)
%RSD
Limit
%RSD ΔP Result
Cert. ID: 146DB627-CD0F-4E66-9432-B4C1012562E1
NA NA 96 6.72 1.00 648 NA NA NA FIOTAF-03 (CFM) 648
comments: NA
Cert. ID: B40B8CF2-0D18-45D9-B67B-B4C1012562E1
NA NA 94 6.72 1.00 633 NA NA NA FIOTAF-04 (CFM) 633
comments: NA www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 3/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
TAF INSTALLATION LEAK TEST RESULTS: Hazardous Sterile Ante Room
PAO (μg/l)% Patched AreaFilter ID
Initial Final
Leakage Diagram (Magnitude, Location, and Dimension)
% Leak Conc. Result
Conc.Max Min Max Initial Final Max
TAF-03 No Diagram 0.00 0.00 3.00 29 10 100 0.000 NA 0.010 Pass comments: NA
TAF-04 No Diagram 0.00 0.00 3.00 30 10 100 0.000 NA 0.010 Pass comments: NA www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 4/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
Pressurization Data
Zone (+) Zone (-) Actual ΔP ("wc)
Min ΔP ("wc)
Max ΔP ("wc)
Directional Airflow
Door Gauge Readings ("wc) Meets CriteriaClosed ("wc) Open ("wc)
Hazardous Sterile Ante Room
Hazardous Storage Room
0.050 0.020 NA Pass NA NA Yes comments: NA
Hazardous Sterile Ante Room
Adjacent Room 0.032 0.020 NA Pass NA NA Yes comments: NA www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 5/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
Airborne Nonviable Particle Count Test Report Clean Zone: Hazardous Sterile Ante
Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-7 Area: 227.26 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 6480 NA NA 6480 Pass
2) 3746 NA NA 3746 Pass
3) 2786 NA NA 2786 Pass
4) 3693 NA NA 3693 Pass
5) 2173 NA NA 2173 Pass
6) 1453 NA NA 1453 Pass
T. C° % rH
21.2 55
21.2 56
21.2 56
21.3 57
21.4 57
21.3 57
Class Limit: 352,000 21.3 56
Sample Volume Test: Pass
Class Limit Location Test: Pass www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 6/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
Airborne Nonviable Particle Count Test Report Clean Zone: Hazardous Sterile Ante
Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-7 Area: 227.26 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 7/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
Cleanroom Diagram:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 8/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Ante Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104810
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
006337 Evergreen Telemetry S-PVF-1 1900817C 10/2026
009016 TEC PH-4 4132 11/2026
009464 Climet CI-750t 057234 11/2026
009747 Evergreen Telemetry Wrist Reporter WR-401 2C03501 09/2026
009752 Evergreen Telemetry Three Pounder 2200368B 09/2026
012839 TEC AG-E3 4952 10/2026
013812 Govee H5075 EQ13812 10/2026 www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:57 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 9/9 I certify that this record is a true and accurate
(800) 877-7742
Test Report
General Information:
Project Site: VA Fresno
2615 East Clinton Avenue
Fresno, CA 93703
Room: Hazardous Sterile Buffer Room
Test Report ID: DV26910104837
Project ID: NC-VFR2627401A-1
Project Contact: Travis Horn
VFR01 | VA Fresno
(559) 225-6100
Travis.Horn@va.gov
Project Lead Tech: Daniel Velazquez
823 Kifer Rd
Sunnyvale, CA 94086 tel: (800) 877-7742 fax: (510) 845-5595
Project Description: TH T3 Building 24 Pharmacy Testing Sept 2026 AL
Technician Remarks: NA
Test Standards: USP <800>, IEST-RP-CC006 www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 1/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
Room Description:
Building: 24
Room: Hazardous Sterile Buffer Room
Room Size:
Area (ft²): 110.00 Volume (ft³): 943
Area (m²): 10.22 Volume (m³): 27
Room Design:
ISO-7
Results
Inspected Min Max Measured Results
Airflow Volume (CFM) NA NA 722 FIO
Grand Mean (FPM) NA NA NA NA
Airflow Uniformity (%RSD) NA NA NA NA
Average Velocities (FPM) * * * FIO
Individual Unit Uniformity (%RSD) * * * NA
Leak Test (%) * * * Pass
Patch (% of Filter Area) * * * Pass
Room Air Exchange Rate (AC/H) 30 NA 46 Pass
Airborne Nonviable Particle Count * * * Pass
Differential Pressure * * * Pass
* Footnote – Results are aggregate of all units tested; individual unit criterion noted in the following pages.
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 2/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
TAF AIRFLOW MEASUREMENTS: Hazardous Sterile Buffer Room
Filter ID Individual Measurements Lower Limit
Upper Limit
Avg Vel (fpm)
Area (ft²)
Kv Avg Vol (cfm)
%RSD
Limit
%RSD ΔP Result
Cert. ID: AEBB45B6-C6CE-44EB-9BE1-B4C10125928B
NA NA 116 3.36 1.00 391 NA NA NA FIOTAF-01 (CFM) 391
comments: NA
Cert. ID: 3399BEFC-E1DB-4F89-940C-B4C10125928B
NA NA 99 3.36 1.00 331 NA NA NA FIOTAF-02 (CFM) 331
comments: NA www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 3/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
TAF INSTALLATION LEAK TEST RESULTS: Hazardous Sterile Buffer Room
PAO (μg/l)% Patched AreaFilter ID
Initial Final
Leakage Diagram (Magnitude, Location, and Dimension)
% Leak Conc. Result
Conc.Max Min Max Initial Final Max
TAF-01 No Diagram 0.00 0.00 3.00 48 10 100 0.000 NA 0.010 Pass comments: NA
TAF-02 No Diagram 0.00 0.00 3.00 57 10 100 0.000 NA 0.010 Pass comments: NA www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 4/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
Pressurization Data
Zone (+) Zone (-) Actual ΔP ("wc)
Min ΔP ("wc)
Max ΔP ("wc)
Directional Airflow
Door Gauge Readings ("wc) Meets CriteriaClosed ("wc) Open ("wc)
Hazardous Sterile Ante Room
Hazardous Sterile Buffer Room
0.024 0.010 0.030 Pass 0.021 0.000 Yes comments: NA www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 5/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
Airborne Nonviable Particle Count Test Report Clean Zone: Hazardous Sterile Buffer
Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-7 Area: 110.00 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 21066 NA NA 21066 Pass
2) 6440 NA NA 6440 Pass
3) 5680 NA NA 5680 Pass
4) 3400 NA NA 3400 Pass
5) 10026 NA NA 10026 Pass
6) 19026 NA NA 19026 Pass
T. C° % rH
21.0 55
21.0 55
21.2 56
21.2 57
21.1 57
21.1 56
Class Limit: 352,000 21.1 56
Sample Volume Test: Pass
Class Limit Location Test: Pass www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 6/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
Airborne Nonviable Particle Count Test Report Clean Zone: Hazardous Sterile Buffer
Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 09/2026 Class: ISO-7 Area: 110.00 ft² Flow Rate: 75.0 LPM
Retest Date: 03/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 7/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID: NC-VFR2627401A-1 Technician: Daniel Velazquez Report ID: DV26910104837
Cleanroom Diagram:
www.techsafety.com
Report Date: 09/10/2026
This record was electronically signed by:Retest Date: 03/2027 eData: v 8.0.3.1
Daniel Velazquez 09/10/2026 12:29 PM Print Version: Service Manager v8.0.3.1
Field Service TechnicianPrint Date: 09/10/2026 Page: 8/9 I certify that this record is a true and accurate
(800) 877-7742
Client: VA Fresno Test Date(s): 09/2026 Room: Hazardous Sterile Buffer Room
Proj. ID:…