Attachment 4 - VFR2627601A-1.03 Aug 2026.USP Testing.Appendix.pdf
PDF 2 MB Posted
- Attached to
- VACCHCS Pharmacy Certification
- Solicitation number
- 36C26127Q0099
About this file
This document is a Testing and Certification Appendix containing comprehensive laboratory and field testing results for pharmaceutical facility cleanroom certification at VA Fresno (2615 East Clinton Avenue, Fresno, CA 93703), dated August 3, 2026, under Service Order NC-VFR2627601A-1. The testing was conducted by Technical Safety Services (TSS) and covers certification of two Baker EG4252 Clean Bench units (Serial Numbers 86796 and 86809) installed in the InPatient Pharmacy IV Room, along with environmental sampling of Building 1 Sterile Compounding areas.
The certification package includes Unidirectional Flow Device Certification Reports for both units, demonstrating compliance with USP <797>, CETA CAG-003, and IEST-RP-CC002.4 standards. Both units achieved "Unit Certified" status with outflow velocities of 98-99 FPM (within 80-100 FPM specification), zero HEPA filter leakage, and aerosol concentrations of 21 µg/l (within 10-100 µg/l range). Airborne Nonviable Particle Count testing confirmed ISO-5 classification for both units with zero particle counts ≥0.5 µm. Airflow Visualization Studies confirmed unidirectional flow patterns without reflux in both benches. Additionally, comprehensive viable and non-viable environmental sampling was performed across ISO-5, ISO-7, and ISO-8 classified areas, with microbial analysis showing acceptable results per USP <797> and CETA CAG-009 standards. The Ante Room (ISO-8) and IV Room (ISO-7) passed pressurization testing with directional airflow from cleaner to less clean spaces. All NIST-traceable calibration equipment used maintains current calibration through 2026-2027, and retest certification is scheduled for February 2027.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Unidirectional Flow Device Certification Report
4225 Executive Square, Suite 370
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2683104856 Facility: VA Fresno ID: 300002 Cust ID: 6640-21882
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86796Bld:
Email: Travis.Horn@va.gov InPatient pharmacy IV room Class: NA Type: Clean BenchRm:
Test Standard(s): USP <797>, CETA CAG-003, IEST-RP-CC002.4, USP <797> 2023
Results
Inspected Min Max Measured Results
Outflow Velocity (FPM) 80 100 98 Pass
%RSD NA 15 4 Pass
Supply Delta Pressure ("W.C.) NA NA NA NA
Duct Pressure ("W.C.) NA NA NA NA
Backstreaming Test NA NA Pass Pass
Induction Leak Test NA NA
Fluorescent Lighting (FC)
Ultraviolet Lighting (μW/cm²) NA
NANA
NA
NANA
NA NA
NANoise Level (dBA) NA NA NA
NAVibration (in. RMS) NA NA NA
NAElectrical Current Leakage Test (mA) NA NA NA
NAElectrical Ground Resistance Test (Ohms) NA NA NA
NAElectrical Polarity NA NA NA
NAElectrical GCFI NA NA NA supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.15/New:0.00/Tot:0.15 Pass
Aerosol Concentration (ug/l) 10 100 21 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Report Date: 08/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 02/2027 eData: v8.0.2.2 Daniel Velazquez 08/03/2026 01:50 PM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/2026 Page: 1/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
Ver. 20 Aug 2026
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2683104856 Facility: VA Fresno ID: 300002 Cust ID: 6640-21882
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86796Bld:
Email: Travis.Horn@va.gov InPatient pharmacy IV room Class: NA Type: Clean BenchRm:
supply
Velocity (FPM) Dimension: Width: 46.00" Height: 28.00" Average Velocity (FPM) 98
Area (ft²): 8.94
Readings: Volume (CFM): 876
104 100 96 99
102 97 92 96
102 99 93 97
Report Date: 08/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 02/2027 eData: v8.0.2.2 Daniel Velazquez 08/03/2026 01:50 PM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/2026 Page: 2/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
(800) 877-7742
Cert. No.: DV2683104735 Svc. Order: NC-VFR2627601A-1 Make: BAKER
Facility: VA Fresno Building: 2615 Model: EG4252
Address: 2615 East Clinton Avenue Room: InPatient pharmacy IV room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 86796
Airborne Nonviable Particle Count Test Report Clean Zone: 86796 Status: Operational/Dynamic Cust ID: 6640-21882 Duration: 1.0 Min(s).
Report Date: 08/2026 Class: ISO-5 Area: 8.94 ft² Flow Rate: 75.0 LPM
Retest Date: 02/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 0 NA NA 0 Pass
T. C° % rH
25.0 55
Class Limit: 3,520 25.0 55
Sample Volume Test: Pass
Class Limit Location Test: Pass
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
This record was electronically signed by:
Page: 1/2 web: www.techsafety.com Daniel Velazquez 8/3/2026 10:48:03 AM eData v8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.Print Date: 08/20/2026
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Cert. No.: DV2683104735 Svc. Order: NC-VFR2627601A-1 Make: BAKER
Facility: VA Fresno Building: 2615 Model: EG4252
Address: 2615 East Clinton Avenue Room: InPatient pharmacy IV room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 86796
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
013812 Govee H5075 EQ13812 10/2026
009464 Climet CI-750t 057234 11/2026 www.techsafety.com
This record was electronically signed by:
Page: 2/2 web: www.techsafety.com Daniel Velazquez 8/3/2026 10:48:03 AM eData v8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.Print Date: 08/20/2026
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
Airflow Visualization Study
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2683104530 Facility: VA Fresno ID: 300002 Cust ID: 6640-21882
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86796Bld:
Email: Travis.Horn@va.gov InPatient pharmacy IV room Class: NA Type: Clean BenchRm:
Service Type: Airflow Visualization Study
Comments: (Dynamic) Tracer moves in a unidirectional manner without reflux. Actions of the personnel do not affect the general trajectory of tracer.
Doc. Title Doc. # Doc. Version Completed Date Originally Retained By
Diagram NA NA 08/03/2026 Daniel Velazquez www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: NA eData v8.0.2.2 Daniel Velazquez 08/03/2026 10:46 AM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/20/2026 Page: 1/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2683104530 Facility: VA Fresno ID: 300002 Cust ID: 6640-21882
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86796Bld:
Email: Travis.Horn@va.gov InPatient pharmacy IV room Class: NA Type: Clean BenchRm:
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: NA eData v8.0.2.2 Daniel Velazquez 08/03/2026 10:46 AM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/20/2026 Page: 2/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
(800) 877-7742
Cert.: DV268310498 Facility: VA Fresno ID: 300003 Cust ID: 6640-21883
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86809Bld:
Email: Travis.Horn@va.gov Inpatient Pharmacy IV room Class: NA Type: Clean BenchRm:
Test Standard(s): CETA CAG-003, IEST-RP-CC002.4, USP <797> 2023
Results
Inspected Min Max Measured Results
Outflow Velocity (FPM) 80 100 99 Pass
%RSD NA 15 4 Pass
Supply Delta Pressure ("W.C.) NA NA NA NA
Duct Pressure ("W.C.) NA NA NA NA
Backstreaming Test NA NA Pass Pass
Induction Leak Test NA NA
Fluorescent Lighting (FC)
Ultraviolet Lighting (μW/cm²) NA
NANA
NA
NANA
NA NA
NANoise Level (dBA) NA NA NA
NAVibration (in. RMS) NA NA NA
NAElectrical Current Leakage Test (mA) NA NA NA
NAElectrical Ground Resistance Test (Ohms) NA NA NA
NAElectrical Polarity NA NA NA
NAElectrical GCFI NA NA NA supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.010 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.010 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 21 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Report Date: 08/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 02/2027 eData: v8.0.2.2 Daniel Velazquez 08/03/2026 01:56 PM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/2026 Page: 1/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
(800) 877-7742
Cert.: DV268310498 Facility: VA Fresno ID: 300003 Cust ID: 6640-21883
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86809Bld:
Email: Travis.Horn@va.gov Inpatient Pharmacy IV room Class: NA Type: Clean BenchRm:
Velocity (FPM) Dimension: Width: 46.00" Height: 28.00" Average Velocity (FPM) 99
Area (ft²): 8.94
Readings: Volume (CFM): 885
92 105 96 98
102 94 97 101
103 95 96 104
Report Date: 08/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 02/2027 eData: v8.0.2.2 Daniel Velazquez 08/03/2026 01:56 PM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/2026 Page: 2/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Cert. No.: DV2683104810 Svc. Order: NC-VFR2627601A-1 Make: BAKER
Facility: VA Fresno Building: 2615 Model: EG4252
Address: 2615 East Clinton Avenue Room: Inpatient Pharmacy IV room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 86809
Airborne Nonviable Particle Count Test Report Clean Zone: 86809 Status: Operational/Dynamic Cust ID: 6640-21883 Duration: 1.0 Min(s).
Report Date: 08/2026 Class: ISO-5 Area: 8.94 ft² Flow Rate: 75.0 LPM
Retest Date: 02/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 0 NA NA 0 Pass
T. C° % rH
24.9 54
Class Limit: 3,520 24.9 54
Sample Volume Test: Pass
Class Limit Location Test: Pass
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
This record was electronically signed by:
Page: 1/2 web: www.techsafety.com Daniel Velazquez 8/3/2026 10:48:41 AM eData v8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.Print Date: 08/20/2026
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Cert. No.: DV2683104810 Svc. Order: NC-VFR2627601A-1 Make: BAKER
Facility: VA Fresno Building: 2615 Model: EG4252
Address: 2615 East Clinton Avenue Room: Inpatient Pharmacy IV room Unit Type: Clean Bench
Fresno, CA 93703 Contact: Travis Horn SN: 86809
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
013812 Govee H5075 EQ13812 10/2026
009464 Climet CI-750t 057234 11/2026 www.techsafety.com
This record was electronically signed by:
Page: 2/2 web: www.techsafety.com Daniel Velazquez 8/3/2026 10:48:41 AM eData v8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.Print Date: 08/20/2026
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
(800) 877-7742
Cert.: DV268310476 Facility: VA Fresno ID: 300003 Cust ID: 6640-21883
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86809Bld:
Email: Travis.Horn@va.gov Inpatient Pharmacy IV room Class: NA Type: Clean BenchRm:
Service Type: Airflow Visualization Study
Comments: (Dynamic) Tracer moves in a unidirectional manner without reflux. Actions of the personnel do not affect the general trajectory of tracer.
Doc. Title Doc. # Doc. Version Completed Date Originally Retained By
Diagram NA NA 08/03/2026 Daniel Velazquez www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: NA eData v8.0.2.2 Daniel Velazquez 08/03/2026 10:47 AM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/20/2026 Page: 1/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
(800) 877-7742
Cert.: DV268310476 Facility: VA Fresno ID: 300003 Cust ID: 6640-21883
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: BAKER
Contact: Travis Horn Fresno, CA 93703 Model: EG4252
Phone: (559) 225-6100 Ext.5735 2615 SN: 86809Bld:
Email: Travis.Horn@va.gov Inpatient Pharmacy IV room Class: NA Type: Clean BenchRm:
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: NA eData v8.0.2.2 Daniel Velazquez 08/03/2026 10:47 AM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/20/2026 Page: 2/2 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
Viable Sample Report
La Jolla, CA 92037
800.877.7742
Cert.: DV268310656 Facility: VA Fresno ID: 20998566 Cust ID: NA
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 1 SN: **Semi Annual** Building 1 Sterile Compounding
Email: Travis.Horn@va.gov Rm: Building 1 Sterile Compoundin Class: NA Type: Environmental Sampling
Area Status: Operational/Dynamic
Occupants: TSS: 1 Client: 1
14 - Active Air Samples
Sample ID Location Type
Sample Size Media Lot # Exp. Date
A-01 ISO-5 1000 Liters TSA Settling Plate 681632P 08/2026
A-02 ISO-5 1000 Liters TSA Settling Plate 681632P 08/2026
A-03 ISO-5 1000 Liters TSA Settling Plate 681632P 08/2026
A-04 ISO-5 1000 Liters TSA Settling Plate 681632P 08/2026
A-06 ISO-7 1000 Liters TSA Settling Plate 681632P 08/2026
A-07 ISO-7 1000 Liters TSA Settling Plate 681632P 08/2026
A-08 ISO-7 1000 Liters TSA Settling Plate 681632P 08/2026
A-10 ISO-8 1000 Liters TSA Settling Plate 681632P 08/2026
A-11 ISO-8 1000 Liters TSA Settling Plate 681632P 08/2026
A-12 ISO-8 1000 Liters TSA Settling Plate 681632P 08/2026
A-13 ISO-8 1000 Liters TSA Settling Plate 681632P 08/2026
A-18 CNC 1000 Liters TSA Settling Plate 681632P 08/2026
A-19 CNC 1000 Liters TSA Settling Plate 681632P 08/2026
Control NA NA TSA Settling Plate 681632P 08/2026
14 - Surface Samples
Sample ID Location Type
Sample Size Media Lot # Exp. Date
Control NA NA TSA Contact Plate 684400P 10/2026
S-01 ISO-5 1 Plate TSA Contact Plate 684400P 10/2026
S-02 ISO-5 1 Plate TSA Contact Plate 684400P 10/2026
S-03 ISO-5 1 Plate TSA Contact Plate 684400P 10/2026
S-04 ISO-5 1 Plate TSA Contact Plate 684400P 10/2026
S-06 ISO-7 1 Plate TSA Contact Plate 684400P 10/2026
S-07 ISO-7 1 Plate TSA Contact Plate 684400P 10/2026
S-08 ISO-7 1 Plate TSA Contact Plate 684400P 10/2026
S-10 ISO-8 1 Plate TSA Contact Plate 684400P 10/2026
S-11 ISO-8 1 Plate TSA Contact Plate 684400P 10/2026
S-12 ISO-8 1 Plate TSA Contact Plate 684400P 10/2026
S-13 ISO-8 1 Plate TSA Contact Plate 684400P 10/2026 www.techsafety.com
08/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 08/03/2026 10:42 AM eData: v 8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.
Print Date: 08/2026 Page: 1/4
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
800.877.7742
Cert.: DV268310656 Facility: VA Fresno ID: 20998566 Cust ID: NA
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 1 SN: **Semi Annual** Building 1 Sterile Compounding
Email: Travis.Horn@va.gov Rm: Building 1 Sterile Compoundin Class: NA Type: Environmental Sampling
14 - Surface Samples
Sample ID Location Type
Sample Size Media Lot # Exp. Date
S-18 CNC 1 Plate TSA Contact Plate 684400P 10/2026
S-19 CNC 1 Plate TSA Contact Plate 684400P 10/2026
Remarks: NA www.techsafety.com
08/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 08/03/2026 10:42 AM eData: v 8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.
Print Date: 08/2026 Page: 2/4
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
800.877.7742
Cert.: DV268310656 Facility: VA Fresno ID: 20998566 Cust ID: NA
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 1 SN: **Semi Annual** Building 1 Sterile Compounding
Email: Travis.Horn@va.gov Rm: Building 1 Sterile Compoundin Class: NA Type: Environmental Sampling www.techsafety.com
08/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 08/03/2026 10:42 AM eData: v 8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.
Print Date: 08/2026 Page: 3/4
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
La Jolla, CA 92037
800.877.7742
Cert.: DV268310656 Facility: VA Fresno ID: 20998566 Cust ID: NA
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: NA
Contact: Travis Horn Fresno, CA 93703 Model: NA
Phone: (559) 225-6100 Ext.5735 Bld: 1 SN: **Semi Annual** Building 1 Sterile Compounding
Email: Travis.Horn@va.gov Rm: Building 1 Sterile Compoundin Class: NA Type: Environmental Sampling
The following NIST-Traceable equipment were used to collect these viable samples:
Equipment ID Manufacturer Model Serial # Calibration Due
012632 AP BUCK B30120 C103665 10/24/2026
012638 AP BUCK B30120 C103671 10/24/2026
www.techsafety.com
08/2026Sample Date: This record was electronically signed by:
Daniel Velazquez 08/03/2026 10:42 AM eData: v 8.0.2.2
Field Service Technician Print Version: Service Manager v8.0.3.0
I certify that this record is a true and accurate representation of work performed.
Print Date: 08/2026 Page: 4/4
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Test Report
General Information:
Project Site: VA Fresno
2615 East Clinton Avenue
Fresno, CA 93703
Room: Hazardous Storage Room
Test Report ID: DV2683104922
Project ID: NC-VFR2627601A-1
Project Contact: Travis Horn
VFR01 | VA Fresno
(559) 225-6100
Travis.Horn@va.gov
Project Lead Tech: Daniel Velazquez
823 Kifer Rd
Sunnyvale, CA 94086 tel: (800) 877-7742 fax: (510) 845-5595
Project Description: AL T3 Semi-Annual, VA Fresno-Pharmacy Certification Bld 1, AUG 2026
Technician Remarks: NA
Test Standards: TSS SOP 05.06.01.00, USP <800> www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:20 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 1/5 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Hazardous Storage Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104922
Room Description:
Building: 1
Room: Hazardous Storage Room
Room Size:
Area (ft²): 75.78 Volume (ft³): 594
Area (m²): 7.04 Volume (m³): 17
Room Design:
NA
Results
Inspected Min Max Measured Results
Airflow Volume (CFM) NA NA 211 FIO
Grand Mean (FPM) NA NA NA NA
Airflow Uniformity (%RSD) NA NA NA NA
Average Velocities (FPM) * * * FIO
Individual Unit Uniformity (%RSD) * * * NA
Leak Test (%) * * * NA
Patch (% of Filter Area) * * * NA
Room Air Exchange Rate (AC/H) 12 NA 21 Pass
Airborne Nonviable Particle Count * * * NA
Differential Pressure * * * Pass
* Footnote – Results are aggregate of all units tested; individual unit criterion noted in the following pages.
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:20 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 2/5 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Hazardous Storage Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104922
TAF AIRFLOW MEASUREMENTS: Hazardous Storage Room
Filter ID Individual Measurements Lower Limit
Upper Limit
Avg Vel (fpm)
Area (ft²)
Kv Avg Vol (cfm)
%RSD
Limit
%RSD ΔP Result
Cert. ID: EE848EA2-9D6C-44F8-9F20-B49B0125B790
NA NA 53 4.00 1.00 211 NA NA NA FIOExhaust (CFM) 211 comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:20 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 3/5 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Hazardous Storage Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104922
Pressurization Data
Zone (+) Zone (-) Actual ΔP ("wc)
Min ΔP ("wc)
Max ΔP ("wc)
Directional Airflow
Door Gauge Readings ("wc) Meets CriteriaClosed ("wc) Open ("wc)
Ambient Room Hazardous Storage Room
0.011 0.0001 NA Pass 0.011 0.000 Yes comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:20 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 4/5 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Hazardous Storage Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104922
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
006337 Evergreen Telemetry S-PVF-1 1900817C 10/2026
009747 Evergreen Telemetry Wrist Reporter WR-401 2C03501 08/2026
009752 Evergreen Telemetry Three Pounder 2200368B 08/2026 www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:20 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 5/5 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Test Report
General Information:
Project Site: VA Fresno
2615 East Clinton Avenue
Fresno, CA 93703
Room: Ante Room
Test Report ID: DV2683104251
Project ID: NC-VFR2627601A-1
Project Contact: Travis Horn
VFR01 | VA Fresno
(559) 225-6100
Travis.Horn@va.gov
Project Lead Tech: Daniel Velazquez
823 Kifer Rd
Sunnyvale, CA 94086 tel: (800) 877-7742 fax: (510) 845-5595
Project Description: AL T3 Semi-Annual, VA Fresno-Pharmacy Certification Bld 1, AUG 2026
Technician Remarks: NA
Test Standards: TSS SOP 05.06.01.00, CETA CAG-003, IEST-RP-CC006, USP <797> 2023 www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 1/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
Room Description:
Building: 2615
Room: Ante Room
Room Size:
Area (ft²): 142.36 Volume (ft³): 1,365
Area (m²): 13.23 Volume (m³): 39
Room Design:
ISO-8
Results
Inspected Min Max Measured Results
Airflow Volume (CFM) NA NA 478 FIO
Grand Mean (FPM) NA NA NA NA
Airflow Uniformity (%RSD) NA NA NA NA
Average Velocities (FPM) * * * Pass
Individual Unit Uniformity (%RSD) * * * NA
Leak Test (%) * * * Pass
Patch (% of Filter Area) * * * Pass
Room Air Exchange Rate (AC/H) 15 NA 21 Pass
PEC Air Exchange Rate (AC/H) NA NA 48 FIO
Room Air Exchange Rate + PEC (AC/H) 20 NA 69 Pass
Airborne Nonviable Particle Count * * * Pass
Differential Pressure * * * Pass
* Footnote – Results are aggregate of all units tested; individual unit criterion noted in the following pages.
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 2/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
TAF AIRFLOW MEASUREMENTS: Ante Room
Filter ID Individual Measurements Lower Limit
Upper Limit
Avg Vel (fpm)
Area (ft²)
Kv Avg Vol (cfm)
%RSD
Limit
%RSD ΔP Result
Cert. ID: 84C894DE-5BF3-4426-A3DA-B49B0123ECB9
0 1,000 94 5.10 1.00 478 NA NA NA PassTAF-1 (CFM) 478 comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 3/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
TAF INSTALLATION LEAK TEST RESULTS: Ante Room
PAO (μg/l)% Patched AreaFilter ID
Initial Final
Leakage Diagram (Magnitude, Location, and Dimension)
% Leak Conc. Result
Conc.Max Min Max Initial Final Max
TAF-1 No Diagram 0.00 0.00 3.00 26 10 100 0.000 NA 0.010 Pass comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 4/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
Pressurization Data
Zone (+) Zone (-) Actual ΔP ("wc)
Min ΔP ("wc)
Max ΔP ("wc)
Directional Airflow
Door Gauge Readings ("wc) Meets CriteriaClosed ("wc) Open ("wc)
Ante Room Ambient Room 0.073 0.020 NA Pass 0.091 0.000 Yes comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 5/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
Airborne Nonviable Particle Count Test Report Clean Zone: Ante Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 08/2026 Class: ISO-8 Area: 142.36 ft² Flow Rate: 75.0 LPM
Retest Date: 02/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 3146 NA NA 3146 Pass
2) 1826 NA NA 1826 Pass
3) 2706 NA NA 2706 Pass
4) 4653 NA NA 4653 Pass
5) 3813 NA NA 3813 Pass
6) 2840 NA NA 2840 Pass
T. C° % rH
22.1 55
22.4 54
22.5 56
22.5 56
22.4 55
22.4 55
Class Limit: 3,520,000 22.4 55
Sample Volume Test: Pass
Class Limit Location Test: Pass www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 6/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
Airborne Nonviable Particle Count Test Report Clean Zone: Ante Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 08/2026 Class: ISO-8 Area: 142.36 ft² Flow Rate: 75.0 LPM
Retest Date: 02/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 7/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
Cleanroom Diagram:
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 8/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: Ante Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683104251
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
006337 Evergreen Telemetry S-PVF-1 1900817C 10/2026
009016 TEC PH-4 4132 11/2026
009464 Climet CI-750t 057234 11/2026
009747 Evergreen Telemetry Wrist Reporter WR-401 2C03501 08/2026
009752 Evergreen Telemetry Three Pounder 2200368B 08/2026
012839 TEC AG-E3 4952 10/2026
013812 Govee H5075 EQ13812 10/2026 www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:15 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 9/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Test Report
General Information:
Project Site: VA Fresno
2615 East Clinton Avenue
Fresno, CA 93703
Room: IV Room
Test Report ID: DV2683102910
Project ID: NC-VFR2627601A-1
Project Contact: Travis Horn
VFR01 | VA Fresno
(559) 225-6100
Travis.Horn@va.gov
Project Lead Tech: Daniel Velazquez
823 Kifer Rd
Sunnyvale, CA 94086 tel: (800) 877-7742 fax: (510) 845-5595
Project Description: AL T3 Semi-Annual, VA Fresno-Pharmacy Certification Bld 1, AUG 2026
Technician Remarks: NA
Test Standards: CETA CAG-003, IEST-RP-CC006, USP <797> 2023 www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 1/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
Room Description:
Building: 2615
Room: IV Room
Room Size:
Area (ft²): 75.00 Volume (ft³): 800
Area (m²): 6.97 Volume (m³): 23
Room Design:
ISO-7
Results
Inspected Min Max Measured Results
Airflow Volume (CFM) NA NA 274 FIO
Grand Mean (FPM) NA NA NA NA
Airflow Uniformity (%RSD) NA NA NA NA
Average Velocities (FPM) * * * Pass
Individual Unit Uniformity (%RSD) * * * NA
Leak Test (%) * * * Pass
Patch (% of Filter Area) * * * Pass
Room Air Exchange Rate (AC/H) 15 NA 21 Pass
PEC Air Exchange Rate (AC/H) NA NA 132 FIO
Room Air Exchange Rate + PEC (AC/H) 30 NA 153 Pass
Airborne Nonviable Particle Count * * * Pass
Differential Pressure * * * Pass
* Footnote – Results are aggregate of all units tested; individual unit criterion noted in the following pages.
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 2/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
TAF AIRFLOW MEASUREMENTS: IV Room
Filter ID Individual Measurements Lower Limit
Upper Limit
Avg Vel (fpm)
Area (ft²)
Kv Avg Vol (cfm)
%RSD
Limit
%RSD ΔP Result
Cert. ID: A4136827-BA70-45FB-A72D-B49B01202B41
0 1,000 52 2.34 1.00 121 NA NA NA PassTAF-1 (CFM) 121 comments: NA
Cert. ID: A5F8729D-15D0-433F-8A29-B49B01202B45
0 1,000 65 2.34 1.00 153 NA NA NA PassTAF-2 (CFM) 153 comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 3/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
TAF INSTALLATION LEAK TEST RESULTS: IV Room
PAO (μg/l)% Patched AreaFilter ID
Initial Final
Leakage Diagram (Magnitude, Location, and Dimension)
% Leak Conc. Result
Conc.Max Min Max Initial Final Max
TAF-1 No Diagram 0.00 0.00 3.00 26 10 100 0.000 NA 0.010 Pass comments: NA
TAF-2 No Diagram 0.00 0.00 3.00 26 10 100 0.000 NA 0.010 Pass comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 4/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
Pressurization Data
Zone (+) Zone (-) Actual ΔP ("wc)
Min ΔP ("wc)
Max ΔP ("wc)
Directional Airflow
Door Gauge Readings ("wc) Meets CriteriaClosed ("wc) Open ("wc)
IV Room Ante Room 0.163 0.020 NA Pass 0.170 0.000 Yes comments: NA www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 5/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
Airborne Nonviable Particle Count Test Report Clean Zone: IV Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 08/2026 Class: ISO-7 Area: 75.00 ft² Flow Rate: 75.0 LPM
Retest Date: 02/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Testing is performed to satisfy ISO 14644-1:2015
Pass PPCM (um) ≥ 0.5
Loc Count 1 Count 2 Count 3 Average Result
1) 1080 NA NA 1080 Pass
2) 506 NA NA 506 Pass
3) 546 NA NA 546 Pass
4) 2693 NA NA 2693 Pass
T. C° % rH
24.7 53
24.7 52
24.8 54
24.9 55
Class Limit: 352,000 24.8 53
Sample Volume Test: Pass
Class Limit Location Test: Pass www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 6/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
Airborne Nonviable Particle Count Test Report Clean Zone: IV Room Status: Operational/Dynamic Cust ID: NA Duration: 1.0 Min(s).
Report Date: 08/2026 Class: ISO-7 Area: 75.00 ft² Flow Rate: 75.0 LPM
Retest Date: 02/2027 Occupants: 1 Total Sample Vol.: 75.0 L
Airborne Nonviable Particle Count Diagram:
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 7/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
Cleanroom Diagram:
www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 8/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
(800) 877-7742
Client: VA Fresno Test Date(s): 08/2026 Room: IV Room
Proj. ID: NC-VFR2627601A-1 Technician: Daniel Velazquez Report ID: DV2683102910
The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial # Calibration Due
006337 Evergreen Telemetry S-PVF-1 1900817C 10/2026
009016 TEC PH-4 4132 11/2026
009464 Climet CI-750t 057234 11/2026
009747 Evergreen Telemetry Wrist Reporter WR-401 2C03501 08/2026
009752 Evergreen Telemetry Three Pounder 2200368B 08/2026
012839 TEC AG-E3 4952 10/2026
013812 Govee H5075 EQ13812 10/2026 www.techsafety.com
Report Date: 08/03/2026
This record was electronically signed by:Retest Date: 02/2027 eData: v 8.0.2.2
Daniel Velazquez 08/03/2026 02:04 PM Print Version: Service Manager v8.0.3.0
Field Service TechnicianPrint Date: 08/20/2026 Page: 9/9 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
Single Pass Certification Report
La Jolla, CA 92037
(800) 877-7742
Cert.: DV2683104941 Facility: VA Fresno ID: 348536 Cust ID: NA
SO: NC-VFR2627601A-1 Addr: 2615 East Clinton Avenue Make: OMNITEC DESIGN
Contact: Travis Horn Fresno, CA 93703 Model: 1200
Phone: (559) 225-6100 Ext.5735 2615 SN: 121661Bld:
Email: Travis.Horn@va.gov Ante Room Class: I Type: Single PassRm:
Test Standard(s): MANUFACTURER
Results
Inspected Min Max Measured Results
Average Inflow Velocity (FPM) 0 NA 809 Pass
Minimum Point Reading (FPM) NA NA 699 NA
Airflow Smoke Pattern NA NA Pass Pass
Lighting Flourescent (FC) NA NA NA NA
Lighting Ultraviolet (uW/cm2) NA NA NA NA
Unit Duct Pressure (In.W.C.) NA NA NA NA
Unit Supply Pressure (In.W.C.) NA NA 0.27 FIO
Airflow Monitor NA NA No FIO
Supply Min Max Measured Results
HEPA As Found Max Point Leak (%) 0.000 0.005 0.000 Pass
HEPA As Left Max Point Leak (%) 0.000 0.005 NA NA
Patch (%) 0 3 Pre:0.00/New:0.00/Tot:0.00 Pass
Aerosol Concentration (ug/l) 10 100 17 Pass
Comments:
**** Unit Certified **** The following NIST-Traceable equipment were used to perform this test:
Equipment ID Manufacturer Model Serial No. Cal. Due Date
005672 TSI 9535 T95351923010 05/2027
009016 TEC PH-4 4132 11/2026
012839 TEC AG-E3 4952 10/2026
Inflow (FPM) Dimension (inches): Width: 14.00 Height: 14.00 Average Inflow Velocity(FPM): 809
Area (sq.ft.): 1.36
Readings:
Volume (CFM): 1,100
853 914
699 769
Report Date: 08/2026 www.techsafety.com
This record was electronically signed by:Retest Date: 02/2027 eData: v8.0.2.2 Daniel Velazquez 08/03/2026 02:02 PM
Print Version: Service Manager v8.0.3.0 Field Service Technician
Print Date: 08/2026 Page: 1/1 I certify that this record is a true and accurate representation of work performed.FIO: For Information Only NA: Not Applicable
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix
823 Kifer Rd Sunnyvale, CA 94086 tel: (800) 877-7742 ISO/IEC 17025:2017 Microbial Analysis Report www.techsafety.com
AT-3296/AT-3296.01
VA Fresno NC-VFR2627601A-1Service Order: Sampled Date: 08/03/2026 Lab Project ID: 2621600029 Received Date: 08/04/2026
Clinton Report Date: 08/12/2026 2615 East Clinton Avenue Fresno, CA 93703
Sample Type
ISO
Class
CFU
ResultSample ID Media Result Comments
TSA Settling Plate ISO-5 0 CFU/m^3 No GrowthA-01 Active Air TSA Settling Plate ISO-5 0 CFU/m^3 No GrowthA-02 Active Air TSA Settling Plate ISO-5 0 CFU/m^3 No GrowthA-03 Active Air TSA Settling Plate ISO-5 0 CFU/m^3 No GrowthA-04 Active Air TSA Settling Plate ISO-7 0 CFU/m^3 No GrowthA-06 Active Air TSA Settling Plate ISO-7 0 CFU/m^3 No GrowthA-07 Active Air TSA Settling Plate ISO-7 0 CFU/m^3 No GrowthA-08 Active Air TSA Settling Plate ISO-8 0 CFU/m^3 No GrowthA-10 Active Air TSA Settling Plate ISO-8 0 CFU/m^3 No GrowthA-11 Active Air TSA Settling Plate ISO-8 0 CFU/m^3 No GrowthA-12 Active Air TSA Settling Plate ISO-8 0 CFU/m^3 No GrowthA-13 Active Air TSA Settling Plate CNC 0 CFU/m^3 No GrowthA-18 Active Air TSA Settling Plate CNC 1 CFU/m^3 FIOA-19 Active Air TSA Settling Plate NA 0 CFU/Plate No GrowthControl Active Air
(Control) TSA Contact Plate NA 0 CFU/Plate No GrowthControl Surface TSA Contact Plate ISO-5 0 CFU/Plate No GrowthS-01 Surface TSA Contact Plate ISO-5 0 CFU/Plate No GrowthS-02 Surface TSA Contact Plate ISO-5 0 CFU/Plate No GrowthS-03 Surface TSA Contact Plate ISO-5 0 CFU/Plate No GrowthS-04 Surface TSA Contact Plate ISO-7 0 CFU/Plate No GrowthS-06 Surface TSA Contact Plate ISO-7 0 CFU/Plate No GrowthS-07 Surface TSA Contact Plate ISO-7 0 CFU/Plate No GrowthS-08 Surface TSA Contact Plate ISO-8 0 CFU/Plate No GrowthS-10 Surface TSA Contact Plate ISO-8 0 CFU/Plate No GrowthS-11 Surface TSA Contact Plate ISO-8 0 CFU/Plate No GrowthS-12 Surface TSA Contact Plate ISO-8 2 CFU/Plate AcceptableS-13 Surface TSA Contact Plate CNC 0 CFU/Plate No GrowthS-18 Surface TSA Contact Plate CNC 0 CFU/Plate No GrowthS-19 Surface
Spacer
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix tel: (800) 877-7742 ISO/IEC 17025:2017 Microbial Analysis Report www.techsafety.com
AT-3296/AT-3296.01
VA Fresno NC-VFR2627601A-1Service Order: Sampled Date: 08/03/2026 Lab Project ID: 2621600029 Received Date: 08/04/2026
Clinton Report Date: 08/12/2026 2615 East Clinton Avenue Fresno, CA 93703
Sample Type
ISO
Class
CFU
ResultSample ID Media Result Comments
No Growth: No growth of microorganisms. Sample in compliance with USP <797> and CETA CAG-009 guidance documents.
Acceptable: Growth of microorganisms. Sample in compliance with USP <797> and CETA CAG-009 guidance documents.
FIO: For Information Only.
TNTC: Too Numerous to Count.
OOC: Out of Compliance. Unacceptable concentrations. Sample not in compliance with USP <797> and CETA CAG-009 guidance documents.
CFU Result: CFU results are reported as CFU/m³ for all Active Air samples, and CFU/plate for all Surface, Fingertip, and Passive
Air samples. TNTC represents a total CFU count that is innumerable. CFU totals are not applicable for Media Fill samples.
TBD: To be determined.
Report Reviewed/Authorized By: Kristi Molina, MLT(ASCP) (Lab Technologist) 08/12/2026 02:04 pm
Spacer
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix tel: (800) 877-7742 ISO/IEC 17025:2017 www.techsafety.comMicrobial Analysis ReportAT-3296/AT-3296.01
NC-VFR2627601A-1 Sampled Date: 08/03/2026VA Fresno Service Order:
Lab Project ID: 2621600029 Received Date: 08/04/2026
Clinton Report Date: 08/12/2026 2615 East Clinton Avenue Fresno, CA 93703
Sample ID: A-01 Active Air Lab Sample ID: 2621600029-1
Test: USP <797> 2023 Single Media Dual Incubation ID All Growth Plus Pathogenicity ISO Class: ISO-5 Condition of sample upon receipt: Media in good condition Sample Size: 1000 Liters Positive Holes: 380 Alert Limit: NA Positive Hole Corrected Result: 0 CFU/m^3 Action Limit: 1 Final Result: No Growth Media: TSA Settling Plate Lot: 681632P Exp.2026-08-31
Temperature: 30-35 C Start Date: 08/04/2026 10:19 am PDT End Date: 08/06/2026 03:18 pm PDT
Temperature: 20-25 C Start Date: 08/06/2026 03:18 pm PDT End Date: 08/11/2026 02:38 pm PDT
Sample ID: A-02 Active Air Lab Sample ID: 2621600029-2
Test: USP <797> 2023 Single Media Dual Incubation ID All Growth Plus Pathogenicity ISO Class: ISO-5 Condition of sample upon receipt: Media in good condition Sample Size: 1000 Liters Positive Holes: 380 Alert Limit: NA Positive Hole Corrected Result: 0 CFU/m^3 Action Limit: 1 Final Result: No Growth Media: TSA Settling Plate Lot: 681632P Exp.2026-08-31
Temperature: 30-35 C Start Date: 08/04/2026 10:19 am PDT End Date: 08/06/2026 03:18 pm PDT
Temperature: 20-25 C Start Date: 08/06/2026 03:18 pm PDT End Date: 08/11/2026 02:38 pm PDT
Sample ID: A-03 Active Air Lab Sample ID: 2621600029-3
Test: USP <797> 2023 Single Media Dual Incubation ID All Growth Plus Pathogenicity ISO Class: ISO-5 Condition of sample upon receipt: Media in good condition Sample Size: 1000 Liters Positive Holes: 380 Alert Limit: NA Positive Hole Corrected Result: 0 CFU/m^3 Action Limit: 1 Final Result: No Growth Media: TSA Settling Plate Lot: 681632P Exp.2026-08-31
Temperature: 30-35 C Start Date: 08/04/2026 10:19 am PDT End Date: 08/06/2026 03:18 pm PDT
Temperature: 20-25 C Start Date: 08/06/2026 03:19 pm PDT End Date: 08/11/2026 02:38 pm PDT
Spacer
Project: NC-VFR2627601A-1 Test Date: 03 Aug 2026
Testing & Certification Appendix tel: (800) 877-7742 ISO/IEC 17025:2017 www.techsafety.comMicrobial Analysis ReportAT-3296/AT-3296.01
NC-VFR2627601A-1 Sampled Date: 08/03/2026VA Fresno Service Order:
Lab Project ID: 2621600029 Received Date: 08/04/2026
Clinton Report Date: 08/12/2026 2615 East Clinton Avenue Fresno, CA 93703
Sample ID: A-04 Active Air Lab Sample ID: 2621600029-4
Test: USP <797> 2023 Single Media Dual Incubation ID All Growth Plus Pathogenicity ISO Class: ISO-5 Condition of sample upon receipt: Media in good condition Sample Size: 1000 Liters Positive Holes: 380 Alert Limit: NA Positive Hole Corrected Result: 0 CFU/m^3 Action Limit: 1 Final Result: No Growth Media: TSA Settling Plate Lot: 681632P Exp.2026-08-31
Temperature: 30-35 C Start Date: 08/04/2026 10:19 am PDT End Date: 08/06/2026 03:18 pm PDT
Temperature: 20-25 C Start Date: 08/06/2026 03:18 pm PDT End Date: 08/11/2026 02:38 pm PDT
Sample ID: A-06 Active Air Lab Sample ID: 2621600029-5
Test: USP <797> 2023 Single Media Dual Incubation ID All Growth Plus Pathogenicity ISO Class: ISO-7 Condition of sample upon receipt: Media in good condition Sample Size: 1000 Liters Positive Holes: 380 Alert Limit: NA Positive Hole Corrected Result: 0 CFU/m^3 Action Limit: 10 Final Result: No Growth Media: TSA Settling Plate Lot: 681632P Exp.2026-08-31
Temperature: 30-35 C Start Date: 08/04/2026 10:19 am PDT End Date: 08/06/2026 03:18 pm PDT
Tem…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .