This is a Sprinkler Riser List attachment that documents the locations and quantities of sprinkler risers across multiple buildings within the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 (VISN 21) facilities. The attachment provides detailed information for five geographic locations: Palo Alto, Menlo Park, Livermore, and Mountain View.

The spreadsheet identifies specific building numbers, floor counts, riser quantities, and precise riser locations for each facility. Palo Alto contains the most extensive infrastructure with buildings numbered 3 through 701 and auxiliary buildings (MB1-MB4, T6B), featuring multiple risers distributed across stairwells, mechanical rooms, and other designated areas. Menlo Park facilities include buildings 114, 221, 321-334, 347-372, and 400, with riser placements in mechanical rooms, interior rooms, closets, and exterior building locations. Livermore locations span buildings 62, 64-65, 74, 88, 90, T-12, and T-34, with risers positioned at stairwells, hallways, and exterior building sides. Mountain View has a single building (Building 2) with one riser on the first-floor stair. This inventory supports the NFPA 5-Year Sprinkler Testing solicitation (36C26126Q0335) and serves as the reference document for identifying all sprinkler riser locations requiring inspection and testing across the VISN 21 healthcare facilities.

View the file

Other files

File Type Posted
Building Reports Attachment 3.pdf PDF
Building Reports Attachment 1.pdf PDF
Building Reports Attachment 2.pdf PDF
36C26126Q0335 0001.docx DOCX document
Attachment 3 WD 2015-5623.pdf PDF
36C26126Q0335.docx DOCX document
Attachment 1 WD 2015-5637.pdf PDF
Attachment 2 WD 2015-5641.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 Bldg. Floors Risers Location

PALO ALTO
433Stairwell Near rooms; A161, B113, C151
543Stairwell Near rooms; A116, B110, C167
633Stairwell Near rooms;
716Stairwell Near rooms; A109, C1-20
821Stairwell Near rooms; Mech. Room back of Bldg.
921Inside - FACP room
4011Loading dock - Above roll up door
4111Stairwell Near rooms; Mech. Room north east corner
4211Stairwell Near rooms; Inside front door on left
4311Stairwell Near rooms; North east corner of shop (inside Bldg)
5011Stairwell Near rooms; North east corner of warehouse.
5422Stairwell Near rooms; 121 Mechanical Room back of bldg. Stairwell back of bldg. exterior access.
10047Stairwell Near rooms; Stairwells that are located @ exterior walls, except stairwells 1 and 5, interior stairwells.
10142Stairwell Near rooms; EB-130, Exterior wall stairwell
10211Stairwell Near rooms; Mech. Room side of Bldg.
10310
10521(1st floor riser) - in 1st floor room IA-125, (2nd floor riser) - in 1st floor room IA-125
50043(Stair 3) -1st floor mechanical room B1-ME2 , (Stair 4) -1st floor mechanical room B1-ME2 , (Zone 1) -1st floor mechanical room B1-ME2
52015(A-D riser) Mechanical room by FACP, (Admin) Mechanical room by FACP
53014(Boiler room - 117) - 1st floor pool area only , (Basement room - B100) - Basement , (1st floor) - Break room, (2nd floor) - HAC room - C034
50144(Stair 1) - Dry Standpipe, (Stair 2) - Dry Standpipe, (Stair 3) - Dry Standpipe, (Stair 4) - Dry Standpipe
60311Inside - on south wall
61511Inside - on west wall
70154(Stair 1) - Dry Standpipe, (Stair 2) - Dry Standpipe
MB111Stairwell Near rooms; Exterior east side
MB211Stairwell Near rooms; Exterior east side
MB311Stairwell Near rooms; Exterior east side
MB411Stairwell Near rooms; North side of Bldg
T6B11Stairwell Near rooms; Exterior left of bldg. entrance
MENLO PARK
11410
22111North West corner Interior of Bldg.
32111Mechanical Room Exterior entrance South Side
32211
32411Mechanical room E131
32911Room 177
33111Mechanical room 104
33211In Closet to the immediate right of Main Entrance
33426Rooms 112B & C132
34721Room 131
34821Room 150
34921Room 130
35021Room 150
35121Room 150
35221Room 150
36017(A&B Wing) - Inside - Room B001, (C Wing) - Outside of building, (D&E Wing) - Inside - Room E001, (F&G Wing) - Inside - Room F001,(H Wing) - Outside of building , (Pharmacy) Mechanical room 108
36511(Right riser) - Outside - Front of building, (Left riser) - Outside - Front of building
37011Inside - Front end of warehouse
37111Inside - Warehouse area behind gated storage
37211Inside - Closet with alarm panel
40011Inside - Room FAC-1 - in dog training area
410
LIVERMORE
6263Stairwells: East Center and West
6421Hallway near rear loading dock
6511Exterior of Bldg. North Side.
7411Exterior of Bldg. West Side.
8811Room 112
9021Room C111
9021Room A108
T-1211Exterior of Bldg. South Side.
T-3411Exterior of Bldg. North Side.
Mountain View221st floor stair 1