CG1CG1
1. SEE DIMENSION PLANS FOR DIMENSION AND INTERIOR
PARTITION DESIGNATIONS
2. SEE FINISH SCHEDULE FOR INTERIOR FINISHES, U.O.N
3. SEE EXTERIOR ELEVATIONS FOR EXTERIOR FINISHES.
4. SEE LANDSCAPE DRAWINGS FOR EXTERIOR PAVING PLANS
5. SEE EQUIPMENT PLAN FOR EQUIPMENT, FURNITURE AND
BEDS.
6. SEE GI1.1.2 FOR TYPICAL ACCESSORY MOUNTING HEIGHTS
7. SEE 9/AE7.2.3 FOR CASEWORK CONFIGURATION TYPICAL
OF ALL STUDENT ROOMS ON LEVEL 2 AND ALL PATIENT
BEDS ON LEVEL 3. OPPOSITE HAND WHERE OCCURS.
K
AE8.1.4
L
PLFO300
814 SF
GAIT STUDY
B1-135
(600 SF)
AE9.5.2
9' - 0"
PLFO300
PLFO300
PLFO300
PLFO300
AE9.1.1
K
L
GAIT STUDY
B1-135
SYRE300
+9' - 0"
9' - 0"
E
F
G
J
H
AE8.1.11 53
CORRIDOR
CA1-19
ELEVATOR
LOBBY
CA1-18A
H.7
7.157.15
7.34
7.21
AE8.4.3
AE8.4.3
E
F
G
J
H
CORRIDOR
CA1-19
ELEVATOR
LOBBY
CA1-18A
+10' - 0"
+10' - 0"
3.12
H.7
3.23
AE5.3.2
AE9.4.5
3.13 3.13
5'
6" 5'
6"
5'
6"
EQ
5' - 0" 4' - 4 1/2"
AE9.4.5
TYP
3.38
EQ
EQ
GRAPHIC SCALE:
4' 0' 4' 8'
1/4" = 1'-0"
TRUE NORTH
PROJ. NORTH
34°
3801 Miranda Ave., Palo Alto CA
CENTERS FOR AMBULATORY CARE,
POLYTRAUMA AND BLIND REHABILITATION
Polytrauma and Blind Rehabilitation Center
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Seals and Signatures on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
301 BATTERY STREET, 7TH FLOOR
SAN FRANCISCO, CA 94111
T 415.227.0100 F 415.908.0862 www.smithgroup.com
The Design Partnership LLP Architects + Planners
1412 VAN NESS AVE., 2ND FLOOR
SAN FRANCISCO, CA 94109
T 415.777.3737 F 415.777.3476 www.dpsf.com Department of
Veterans Affairs
SHEET NOTES
KEYNOTES
Associate Architect:
ENLARGED PLANS & RCPS LEVEL 1
GAIT STUDY & CORRIDOR CA1-19
AE7.1.11
JG NW20 SEPTEMBER 2011
640-424
3.12 EXPANSION / SEISMIC JOINT
3.13 ROLL DOWN SHADE TYPICAL, SEE SPECIFICATIONS
FOR TYPE. COORDINATE SHADE PULLS FOR
ACCESSIBILITY WITH BRACED FRAMES WHERE
APPLICABLE
3.23 ROLL-UP FIRE DOOR, SEE AE9.3.8 FOR DETAILS
3.38 ACCESS PANEL, 24" X 30"
7.15 RESILIENT TILE FLOORING LVT10
7.21 EXPANSION / SEISMIC JOINT
7.34 ROLL-UP FIRE DOOR
SCALE: 1/4" = 1'-0"30 B1-135 GAIT STUDY
SCALE: 1/4" = 1'-0"27 B1-135 GAIT STUDY-RCP
SCALE: 1/4" = 1'-0"42 CA1-19 BRIDGE
SCALE: 1/4" = 1'-0"54 CA1-19 BRIDGE-RCP
AE9.5.4
AE5.3.2