1. CEILING HEIGHTS INDICATED ARE A.F.F., U.O.N.
2. CENTER SUSPENDED CEILING GRID IN ROOM, U.O.N.
3. CENTER CEILING LIGHT FIXTURES IN CEILING AREAS U.O.N.
4. SEE FINISH SCHEDULE FOR CEILING FINISHES
5. SEE AE9.4.1 FOR TYPICAL CEILING DETAILS.
6. SEE EQUIPMENT REPORT FOR ADDITIONAL INFORMATION.
7. PROVIDE APPROPRIATE BACKING, SUPPORT AND LATERAL
BRACING AS REQUIRED ON ALL CEILING MOUNTED
EQUIPMENT
8. ALL CEILINGS ARE 9'-0" ABOVE FINISHED FLOOR, U.O.N.
9. SEE ELECTRICAL DRAWINGS FOR LOCATION OF ALL EXIT
SIGNS.
10. SEE FIRE ALARM DRAWINGS FOR LOCATION OF ALL SMOKE
DETECTORS.
G
J
N
141 3
H
K
M
L
AE3.1.1C
+10' - 9"
+9' - 0"
+9' - 6"
+9' - 6"
OFFICE
B1-140A
OFFICE
B1-508
OFFICE
B1-524
OFFICE
B1-526
EMS
OFFICE
B1-535
OFFICE
B1-522
OFFICE
B1-528
OFFICE
B1-510
OFFICE
B1-502
EMS EQUIP
B1-536
TOILET
B1-501
OFFICE
B1-531
OFFICE
B1-533
OFFICE
B1-506
OFFICE
B1-504
TCOM
B1-TC1
BED
STORAGE
B1-542
ELECTRICAL
B1-EC2A
QT
B1-140B
EMS
LOUNGE
B1-537
MECHANICAL
ROOM
B1-ME2
SIGNAL
B1-SC1
STUDENT
WORK
ROOM
B1-511
OFFICE
B1-512
OFFICE
B1-520
EMS
SUPPLY
B1-539
TOILET
B1-120F
STAFF SUITE
B1-120G
OUTPATIENT
THERAPY
GYM
B1-120
ASSISTIVE
TECHNOLOGY
B1-130
GAIT STUDY
B1-135
DRIVER
TRAINING
B1-140
COPY ROOM
B1-527
BREAK
ROOM
B1-525
CONFERENCE
ROOM
B1-530
PERSONAL
EFFECTS
B1-507
TOILET
B1-503
EMS
RECEIVING
B1-540
STORAGE
B1-ME1
THERAPY
STORAGE
B1-505
STAIR 3
B1-ST3
COURTYARD
A1-CY1
STORAGE
B1-130C
SOILED
HOLDING
B1-543
QUIET
THERAPY
B1-130B
EMERGENCY
ELECTRICAL
B1-EC2
CORRIDOR
CA1-19
CORRIDOR
CB1-15
CORRIDOR
CB1-16
CORRIDOR
CB1-17
CORRIDOR
CB1-14
GAIT
DRESSING
B1-135A
STORAGE
B1-120D
STORAGE
B1-120E
SYRE300
AE3.1.1A
AE
3.1
.1D
+10' - 0"
3.24
3.08
3.08
3.08
3.08
3.08
AE
3.1
.1C
3.08
7 10
STORAGE
B1-534
AE7.1.11
H.7
TRCE300-
ALCOVE
B1-115A
3.24
+9' - 0"
+9' - 0"
AE7.1.11
3.08
3.08
1/ 2"
11' - 7 1/2"
/2
19' - 11"
EQ EQ
EQ
4'
5"
3.13
3.13
3.13
3.13
3.13
3.13
3.13
AT STAFF
SUITE
B1-130A
AE7.1.10
54+10' - 9"
3.13
3.11
3.11
3.11
CORRIDOR
CB1-10
3.39
1' - 3"1'
0"1' - 6"
1'
3"
2'
0"
9' - 0"
AL
IG
N
2'
1/
2"
+9' - 6"
ALIGN3'
0"
2' - 5 1/2"
AL
IG
N
2'
1/
2"
AE9.4.5
+8' - 0"
+10' - 9"
2 2 2 2 22
2 HR HORIZONTAL EXIT / SMOKE BARRIER
2 HR OCCUPANCY SEPARATION
1 HR RATED
1/2 HR SMOKE PARTITION
SMOKE PREVENTIVE PARTITION
RATED CONSTRUCTION
CEILINGS
SUSPENDED LINEAR WOOD PLANK SYSTEM
2 X 2 SUSPENDED LAY-IN CEILING, SEE
50/AE9.4.1
FRAMED CEILING - FLAT GYPSUM BOARD, SEE
52/AE9.4.1
FRAMED CEILING ABOVE - FLAT GYPSUM
BOARD, 1 HR FIRE RATED, SEE 30/AE9.4.2
GRAPHIC SCALE:
0'
1/8" = 1'-0"
8' 8' 16'
TRUE
NORTH
PROJ. NORTH
34°
3801 Miranda Ave., Palo Alto CA
CENTERS FOR AMBULATORY CARE,
POLYTRAUMA AND BLIND REHABILITATION
Polytrauma and Blind Rehabilitation Center
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Seals and Signatures on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
301 BATTERY STREET, 7TH FLOOR
SAN FRANCISCO, CA 94111
T 415.227.0100 F 415.908.0862 www.smithgroup.com
The Design Partnership LLP Architects + Planners
1412 VAN NESS AVE., 2ND FLOOR
SAN FRANCISCO, CA 94109
T 415.777.3737 F 415.777.3476 www.dpsf.com Department of
Veterans Affairs
SHEET NOTES
KEYNOTES
Associate Architect:
PR
IN
TE
D
ON
:8
/1 2/
:1
4:
P M
RCP LEVEL 1 AREA C
AE3.1.1C
JG NW25 MARCH 2011
640-424
3.08 EXPOSED STRUCTURE
3.11 WALL MOUNTED CASEWORK
3.12 EXPANSION / SEISMIC JOINT
3.13 ROLL DOWN SHADE TYPICAL, SEE SPECIFICATIONS FOR
TYPE. COORDINATE SHADE PULLS FOR ACCESSIBILITY
WITH BRACED FRAMES WHERE APPLICABLE
3.23 ROLL-UP FIRE DOOR, SEE AE9.3.8 FOR DETAILS
3.24 1HR SHAFT BOTTOM ENCLOSURE ABOVE
3.38 ACCESS PANEL, 24" X 30"
3.39 ACCESS PANEL, 30" X 30"
SCALE: 1/8" = 1'-0"54
REFLECTED CEILING PLAN LEVEL 1
AREA C
1 ASI-050 06/27/2013
2 ASI-066 07/31/2013
File details come from the government source that posted it.