CBOC Drawings and Sensor Locations - Future State - Updated 11-17-25.pdf

PDF 2 MB Posted

Attached to
J063, Panic and Intrusion Alarm Replacement and Monitoring, Various Clinics - Portland Veterans Affairs Healthcare System, Dept of Veterans Affairs
Solicitation number
36C26026Q0040
Issued by

About this file

This document is a set of floor plans for multiple Community-Based Outpatient Clinics (CBOCs) detailing proposed security system modifications. The plans cover six different CBOC locations: West Linn, Salem, Fairview, Hillsboro (3rd and 4th floors), Bend (1st and 2nd floors), and The Dalles. Each floor plan includes detailed markings for existing and proposed security sensors, including long-range sensors, door contacts, 360-degree sensors, wireless duress buttons, keypads, and alarm panels.

The proposed modifications involve removing some existing sensors (marked with "X") and adding new sensors at various strategic locations throughout each facility. The proposed additions include sensors in hallways, waiting rooms, administrative areas, counseling rooms, audiology spaces, and exit points. The plans use a consistent color-coded legend to indicate different types of sensor additions: blue for long-range sensors, red for door contacts, pink for 360-degree sensors, and green for wireless duress buttons. Each floor plan provides a comprehensive overview of the current security sensor configuration and the recommended upgrades for each CBOC location.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Keypad

Alarm Panel

WEST LINN CBOC

Fault 11 Center Motion

Fault 03 East

Fault 04 Stairwell

Fault 05 SW Double Door Fault 01

Fault

14 SW Hall Motion

Fault

West Hall

Fault 12 Center

X

X - Remove

- Add Long Range Sensor

- Add Door Contact

- Add 360 Sensor

- Add Wireless Duress Button

SALEM CBOC X - Remove

- Add Long Range Sensor

- Add Door Contact

- Add 360 Sensor

- Add Wireless Duress Button

- Add Keypad

X

X

X

X X

X X X

Blank Page.

Alarm Panel

FAIRVIEW CBOC

Fault 1 Contact Sensor

Fault 3 Contac t S

Fault 7 Motion Sensor

Fault 2 Contac t

Fault 4 Motion Sensor

Fault 6 Motion Sensor

IT/Data Closet Sensor

X - Remove

- Add Long Range Sensor

- Add Door Contact

- Add 360 Sensor

- Add Wireless Duress Button

HILLSBORO CBOC 3rd Floor

Keypad

Sensor 1 Waiting Room

Sensor 2 PC Team

Hall

3A-102

Sensor 3 PC Team Hall

3A135

Sensor 1

PC

Team Hall

Sensor 5 Lab Waiting

3A-170

Sensor 6 PC Hall 3B-119

Sensor 7 Eye Hall 3B-136

Sensor 8 Audiology Hall

3B-150

X - Remove

- Add Long Range Sensor

- Add Door Contact

- Add 360 Sensor

- Add Wireless Duress Button

X

HILLSBORO CBOC 4th Floor

Fault 011 Waiting

Fault 012 Exit

Fault 013 C&P Hall

BEND CBOC 1st Floor

Fault 2 South

Fault 22 Audiology

Fault 23 Counseling

Fault 18 Main Doors

Fault 16 Front Lobby

Fault 3 East

Fault 24 Admin

Fault 20 South

Fault 21 South Hall

X - Remove

- Add Long Range Sensor

- Add Door Contact

- Add 360 Sensor

- Add Wireless Duress Button

- Add Keypad

BEND CBOC 2nd Floor Keypad Alarm Panel

Fault 13 Contact Sensor

Fault 19 Upper East Hall

North Hall Sensor Southwest Hall Sensor

THE DALLES CBOC

Keypad

Alarm Panel

Contact #2 Front Contact #1 Front Contact #3 Southwest

Contact #4 Northwest Exit

X - Remove

- Add Long Range Sensor

- Add Door Contact

- Add 360 Sensor

- Add Wireless Duress Button

- Add Keypad

File details come from the government source that posted it. Updated .