parking12WT handout.pdf

PDF 1 MB Posted

Attached to
Z2DA--623-20-135 Replace & Upgrade parking lots 1 and 2 (VA-22-00033871)
Solicitation number
36C25922R0035
Issued by

About this file

This handout provides details for replacing and upgrading parking lots 1 and 2 at a Department of Veterans Affairs facility. Special conditions notes require verifying clearances for existing solar panel canopies throughout construction and implementing measures to prevent accidental impacts. Temporary measures must also prevent tree leaves and debris from affecting surface finishing. The related federal contract opportunity is solicitation number 36C25922R0035 to replace and upgrade the parking lots for $623,000 under the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19. Responses are due by February 23, 2020.

View the file

Other files

File Type Posted
090600.pdf PDF
36C25922R0035 0003.docx DOCX document
Solar Parking Lot Lighting - Solar Lighting International.pdf PDF
36C25922R0035 0002.pdf PDF
SOW Parking Lots 1 2 revised.docx DOCX document
623-20-135 SPECIFICATIONS 3 1 2022.pdf PDF
36C25922R0035 0001.docx DOCX document
Site Visit Attendance.pdf PDF
623-20-135 SPECIFICATIONS 010722.pdf PDF
623-20-135 DRAWINGS 010722.pdf PDF
36C25922R0035_1.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

SPECIAL CONDITIONS NOTES Q

1A. EXISTING SOLAR PANEL CANOPY WILL AFFECT MAXIMUM EQUIPMENT HEIGHT USED BY CONTRACTOR. ENSURE CLEARANCES ARE

VERIFIED THROUGHOUT CONSTRUCTION ANO APPROPRIATE MEASURES ARE IMPLEMENTED TO PREVENT ACCIDENTAL IMPACT

DAMAGE TO CANOPY.

2A CONTRACTOR SHALL PROVIDE TEMPORARY MEASURES TO PREVENT TREE LEAVES AND OTHER DEBRIS FROM AFFECTING FINAL SURFACE FINISHING OPERATIONS. EXISTING TREES ON SITE OVERHANG PORTIONS OF WORK AREA.

®SATELLITE VIEW DIAGRAM - SPECIAL CONDITlONS

NOTTO SCALE

CONSULTANT

Revisions: o.te:

®EXISTING UTILITY PLAN (FOR REFERENCE ONLY)

SCALE 1ne"�'-<l'

ARCHITECT/ENGINEER OF RECORD STAMP

8 paradigm Architecture I Engineering I Design-Build

200 Envoy Circle, Suite 201, Louisville, KY 40299 www.porcidigmuM.ccim

Office of Construction and Facilities

Drawing Title

N m

EXISTING UTILITY PLAN

(FOR REFERENCE ONLY)

Management 1--~ ,1A I U.S. Department Vft ofVeteransAffairs

A. THE EXISTING TOPOGRAPHIC AND SITE INFORMATION SHOWN HAS BEEN PROVIDED BY:

�GATEWAY SERVICES GROUP, LLC� DATED 12-27-19. FOR MORE INFORMATION CONTACT

GATEWAY SERVICES GROUP, LLC. AT -405-273-0954 OR P .0. BOX 960 MEEKER, OK 74855.

THIS INFORMATION IS PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR. THE

CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN SURVEYING AND UTILITY LOCATING

SERVICES TO VERIFY ALL INFORMATION SHOWN PRIOR TO THE START OF CONSTRUCTION AND

TO IMMEDIATELY NOTIFY THE COR OF DISCREPANCIES BETWEEN THE CONTRACTORS SURVEY

AND THE INFORMATION SHOWN ON THESE DRAWINGS, OTHERWISE THE CONTRACTOR ACCEPTS

LIABILITY FOR ACCURACY OF THE INFORMATION SHOWN; THE CONTRACTOR IS RESPONSIBLE

FOR REPAIRING ANY DAMAGE (RESULTANT OF WORK PERFORMED ACCORDING TO THESE

DOCUMENTS) TO UTILITIES SHOWN ON THE DRAWINGS THAT ARE TO REMAIN.

B. THE EXISTING TOPOGRAPHIC AND SITE UTILITY INFORMATION SHOWN IS AVAILABLE AS A FULL

ELECTRONIC FILE AVAILABLE BY REQUEST FROM THE COR. THIS INFORMATION IS PROVIDED

FOR THE CONVENIENCE OF THE CONTRACTOR. THE VA IS NOT RESPONSIBLE FOR THE

ACCURACY OF THE INFORMATION SHOWN THEREIN. CONTRACTOR SHALL VERIFY ALL

INFORMATION SHOWN.

C. THE CONTRACT DRAWINGS SHOW THE APPROXIMATE LOCATION OF EXISTING UTILITY LINES, MANHOLES, INLETS, ETC. THESE FEATURES HAYE BEEN IDENTIFIED AND LOCATED ON THESE

DRAWINGS AS ACCURATELY AS POSSIBLE USING AVAILABLE INFORMATION AND SURVEY

OPERATIONS.

D. THE CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN SURVEYING AND UTILITY LOCATING

SERVICES TO VERIFY ALL INFORMATION SHOWN PRIOR TO THE START OF CONSTRUCTION AND

TO IMMEDIATELY NOTIFY THE COR OF DISCREPANCIES BETWEEN THE CONTRACTORS SURVEY

AND THE INFORMATION SHOWN ON THESE DRAWINGS. OTHERWISE THE CONTRACTOR ACCEPTS

LIABILITY FOR ACCURACY OF THE INFORMATION SHOWN. THE CONTRACTOR IS RESPONSIBLE

FOR REPAIRING ANY DAMAGE TO UTILITIES TI-M T ARE TO REMAIN IN SERVICE.

E. UNDERGROUND UTILITY LOCATIONS ARE BASED ON FIELD MARKINGS PROVIDED. ACTUAl

LOCATIONS ALSO TO BE CONFIRMED IN FIELD BY CONTRACTOR.

TOPOGRAPHICAL SURVEY NOTES

A. ALL UTILITIES SHOWN HEREON WERE DERIVED FROM A COMBINATION OF UTILITY MAPPING

AND FIELD OBSERVATIONS OF MARKINGS PLACED BY OTHERS. NO CERTIFICATION IS MADE

REGARDING THE ACCURACY OF BURIED UTILITIES. CONTRACTOR IS RESPONSIBLE FOR

PROVIDING A COMPLETE UTILITY LOCATING EFFORT TO VERIFY EXACT LOCATIONS OF EXISTING

UTILITIES WITHIN LIMITS OF WORK AREA SHOWN.

B. THE CONTOURS SHOWN HEREON WERE DERIVED FROM FIELD POINT MEASUREMENTS.

KEYNOTES 0

1. EXISTING UNDERGROUND SOLAR CANOPY ELECTRICAL LINES. DURING ALL PHASES OF

PROJECT, ENSURE THAT NO DAMAGE OCCURS TO THIS LINE OR THAT ANY WORK AFFECTS

THE OPERATIONAL CAPACITY OF THESE LINES. DURING EXCAVATIONS WITHIN 5' OF EXISTING

LINES, EXCAVATION SHALL BE BY HAND DIGGING ONLY, REFER TO SPECIFICATIONS.

2. EXISTING FACIUTY MAIN STORM DRAINAGE LINES TO REMAIN, DO NOT DAMAGE. DURING ALL

PHASES OF PROJECT, ENSURE THAT NO DAMAGE OCCURS TO THESE MAIN LINES OR THAT

ANY WORK AFFECTS THE OPERATIONAL CAPACITY OF THESE LINES. MAIN STORM LINE

OUTFALL OCCURS TO EAST OF ROAD DOWNSLOPE OF LOWER RETAINING WALL (OUTSIDE OF

SCOPE AREA)

3. EXISTING PARKING LOT STORM DRAINAGE LINE. FIELD INVESTIGATIONS SHOW LINE AND

INLETS TO BE SILTED IN. INLETS AND DRAIN LINE TO BE DEMOLISHED AND INFILLED.

4. EXISTING ELECTRICAL EQUIPMENT TO REMAIN, DO NOT DAMAGE.

5. EXISTING RAIL-MOUNT HOSPITAL CALL BOXES. REFER TD NEW WORK PLAN FOR RELOCATION

TO BOTTOM OF RAMPS.

LEGEND

- - - MISC LINE

___ ..,_ GAS LINE

-T- COMMUNICATION LINE

-�- SANITARY _INE

-�- WATER LINE

-,�- OVERHEAD WIRE

_.,_ STORM DRAIN LINE

-•- ELECTRIC _INE

----- CENTERLINE

-------- BUILDING LINE

------ CONCRETE LINE

- - - CURB LINE

- - FENCE LINE - W RE

-11- FENCE LINE - WOOD

---- GRAVEL LINE

- - - EASEMENT LINE

--- PAYING LINE

• BOLLARD / PIPE INVERT / REBAR

@- GAS VALVE

@ITJ COMMUNICATIONS UTILITY

(2)@ SANITARY SEWER CO / MH

@tHl WATER METER / FIRE HYDRANT

◊ � WATER VALVE \ SIAMESE CONNC:CTIO�

@ STORM DRAIN MH

- Ii] STORM DRAIN INLET

TR [ID ELECTRIC UTILITY

◊ LIGHI POLI:..

,JfSIGN

0 DECIDUOUS TREE

one sixteenth inch• one foot

Phase

BID DOCUMENTS

FOR CONSTRUCTION

ProjlCtTitle

REPLACE AND UPGRADE

PARKING LOTS 1 AND 2

Project Number 623-20-135

Bui ding Number

PARKING 1-2

l location JACI.. c. MONTCX'IME:RY VA t.EDK::Al.. CENTel I

Drawing Number . 1111tcNJRHDf!BDR,IIBCOCEE,(X74CJI

File details come from the government source that posted it. Updated .