This handout provides details for replacing and upgrading parking lots 1 and 2 at a Department of Veterans Affairs facility. Special conditions notes require verifying clearances for existing solar panel canopies throughout construction and implementing measures to prevent accidental impacts. Temporary measures must also prevent tree leaves and debris from affecting surface finishing. The related federal contract opportunity is solicitation number 36C25922R0035 to replace and upgrade the parking lots for $623,000 under the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19. Responses are due by February 23, 2020.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 090600.pdf | ||
| 36C25922R0035 0003.docx | DOCX document | |
| Solar Parking Lot Lighting - Solar Lighting International.pdf | ||
| 36C25922R0035 0002.pdf | ||
| SOW Parking Lots 1 2 revised.docx | DOCX document | |
| 623-20-135 SPECIFICATIONS 3 1 2022.pdf | ||
| 36C25922R0035 0001.docx | DOCX document | |
| Site Visit Attendance.pdf | ||
| 623-20-135 SPECIFICATIONS 010722.pdf | ||
| 623-20-135 DRAWINGS 010722.pdf | ||
| 36C25922R0035_1.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
SPECIAL CONDITIONS NOTES Q
1A. EXISTING SOLAR PANEL CANOPY WILL AFFECT MAXIMUM EQUIPMENT HEIGHT USED BY CONTRACTOR. ENSURE CLEARANCES ARE
VERIFIED THROUGHOUT CONSTRUCTION ANO APPROPRIATE MEASURES ARE IMPLEMENTED TO PREVENT ACCIDENTAL IMPACT
DAMAGE TO CANOPY.
2A CONTRACTOR SHALL PROVIDE TEMPORARY MEASURES TO PREVENT TREE LEAVES AND OTHER DEBRIS FROM AFFECTING FINAL SURFACE FINISHING OPERATIONS. EXISTING TREES ON SITE OVERHANG PORTIONS OF WORK AREA.
®SATELLITE VIEW DIAGRAM - SPECIAL CONDITlONS
NOTTO SCALE
CONSULTANT
Revisions: o.te:
®EXISTING UTILITY PLAN (FOR REFERENCE ONLY)
SCALE 1ne"�'-<l'
ARCHITECT/ENGINEER OF RECORD STAMP
8 paradigm Architecture I Engineering I Design-Build
200 Envoy Circle, Suite 201, Louisville, KY 40299 www.porcidigmuM.ccim
Office of Construction and Facilities
Drawing Title
N m
EXISTING UTILITY PLAN
(FOR REFERENCE ONLY)
Management 1--~ ,1A I U.S. Department Vft ofVeteransAffairs
A. THE EXISTING TOPOGRAPHIC AND SITE INFORMATION SHOWN HAS BEEN PROVIDED BY:
�GATEWAY SERVICES GROUP, LLC� DATED 12-27-19. FOR MORE INFORMATION CONTACT
GATEWAY SERVICES GROUP, LLC. AT -405-273-0954 OR P .0. BOX 960 MEEKER, OK 74855.
THIS INFORMATION IS PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR. THE
CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN SURVEYING AND UTILITY LOCATING
SERVICES TO VERIFY ALL INFORMATION SHOWN PRIOR TO THE START OF CONSTRUCTION AND
TO IMMEDIATELY NOTIFY THE COR OF DISCREPANCIES BETWEEN THE CONTRACTORS SURVEY
AND THE INFORMATION SHOWN ON THESE DRAWINGS, OTHERWISE THE CONTRACTOR ACCEPTS
LIABILITY FOR ACCURACY OF THE INFORMATION SHOWN; THE CONTRACTOR IS RESPONSIBLE
FOR REPAIRING ANY DAMAGE (RESULTANT OF WORK PERFORMED ACCORDING TO THESE
DOCUMENTS) TO UTILITIES SHOWN ON THE DRAWINGS THAT ARE TO REMAIN.
B. THE EXISTING TOPOGRAPHIC AND SITE UTILITY INFORMATION SHOWN IS AVAILABLE AS A FULL
ELECTRONIC FILE AVAILABLE BY REQUEST FROM THE COR. THIS INFORMATION IS PROVIDED
FOR THE CONVENIENCE OF THE CONTRACTOR. THE VA IS NOT RESPONSIBLE FOR THE
ACCURACY OF THE INFORMATION SHOWN THEREIN. CONTRACTOR SHALL VERIFY ALL
INFORMATION SHOWN.
C. THE CONTRACT DRAWINGS SHOW THE APPROXIMATE LOCATION OF EXISTING UTILITY LINES, MANHOLES, INLETS, ETC. THESE FEATURES HAYE BEEN IDENTIFIED AND LOCATED ON THESE
DRAWINGS AS ACCURATELY AS POSSIBLE USING AVAILABLE INFORMATION AND SURVEY
OPERATIONS.
D. THE CONTRACTOR IS REQUIRED TO PROVIDE THEIR OWN SURVEYING AND UTILITY LOCATING
SERVICES TO VERIFY ALL INFORMATION SHOWN PRIOR TO THE START OF CONSTRUCTION AND
TO IMMEDIATELY NOTIFY THE COR OF DISCREPANCIES BETWEEN THE CONTRACTORS SURVEY
AND THE INFORMATION SHOWN ON THESE DRAWINGS. OTHERWISE THE CONTRACTOR ACCEPTS
LIABILITY FOR ACCURACY OF THE INFORMATION SHOWN. THE CONTRACTOR IS RESPONSIBLE
FOR REPAIRING ANY DAMAGE TO UTILITIES TI-M T ARE TO REMAIN IN SERVICE.
E. UNDERGROUND UTILITY LOCATIONS ARE BASED ON FIELD MARKINGS PROVIDED. ACTUAl
LOCATIONS ALSO TO BE CONFIRMED IN FIELD BY CONTRACTOR.
TOPOGRAPHICAL SURVEY NOTES
A. ALL UTILITIES SHOWN HEREON WERE DERIVED FROM A COMBINATION OF UTILITY MAPPING
AND FIELD OBSERVATIONS OF MARKINGS PLACED BY OTHERS. NO CERTIFICATION IS MADE
REGARDING THE ACCURACY OF BURIED UTILITIES. CONTRACTOR IS RESPONSIBLE FOR
PROVIDING A COMPLETE UTILITY LOCATING EFFORT TO VERIFY EXACT LOCATIONS OF EXISTING
UTILITIES WITHIN LIMITS OF WORK AREA SHOWN.
B. THE CONTOURS SHOWN HEREON WERE DERIVED FROM FIELD POINT MEASUREMENTS.
KEYNOTES 0
1. EXISTING UNDERGROUND SOLAR CANOPY ELECTRICAL LINES. DURING ALL PHASES OF
PROJECT, ENSURE THAT NO DAMAGE OCCURS TO THIS LINE OR THAT ANY WORK AFFECTS
THE OPERATIONAL CAPACITY OF THESE LINES. DURING EXCAVATIONS WITHIN 5' OF EXISTING
LINES, EXCAVATION SHALL BE BY HAND DIGGING ONLY, REFER TO SPECIFICATIONS.
2. EXISTING FACIUTY MAIN STORM DRAINAGE LINES TO REMAIN, DO NOT DAMAGE. DURING ALL
PHASES OF PROJECT, ENSURE THAT NO DAMAGE OCCURS TO THESE MAIN LINES OR THAT
ANY WORK AFFECTS THE OPERATIONAL CAPACITY OF THESE LINES. MAIN STORM LINE
OUTFALL OCCURS TO EAST OF ROAD DOWNSLOPE OF LOWER RETAINING WALL (OUTSIDE OF
SCOPE AREA)
3. EXISTING PARKING LOT STORM DRAINAGE LINE. FIELD INVESTIGATIONS SHOW LINE AND
INLETS TO BE SILTED IN. INLETS AND DRAIN LINE TO BE DEMOLISHED AND INFILLED.
4. EXISTING ELECTRICAL EQUIPMENT TO REMAIN, DO NOT DAMAGE.
5. EXISTING RAIL-MOUNT HOSPITAL CALL BOXES. REFER TD NEW WORK PLAN FOR RELOCATION
TO BOTTOM OF RAMPS.
LEGEND
- - - MISC LINE
___ ..,_ GAS LINE
-T- COMMUNICATION LINE
-�- SANITARY _INE
-�- WATER LINE
-,�- OVERHEAD WIRE
_.,_ STORM DRAIN LINE
-•- ELECTRIC _INE
----- CENTERLINE
-------- BUILDING LINE
------ CONCRETE LINE
- - - CURB LINE
- - FENCE LINE - W RE
-11- FENCE LINE - WOOD
---- GRAVEL LINE
- - - EASEMENT LINE
--- PAYING LINE
• BOLLARD / PIPE INVERT / REBAR
@- GAS VALVE
@ITJ COMMUNICATIONS UTILITY
(2)@ SANITARY SEWER CO / MH
@tHl WATER METER / FIRE HYDRANT
◊ � WATER VALVE \ SIAMESE CONNC:CTIO�
@ STORM DRAIN MH
- Ii] STORM DRAIN INLET
TR [ID ELECTRIC UTILITY
◊ LIGHI POLI:..
,JfSIGN
0 DECIDUOUS TREE
one sixteenth inch• one foot
Phase
BID DOCUMENTS
FOR CONSTRUCTION
ProjlCtTitle
REPLACE AND UPGRADE
PARKING LOTS 1 AND 2
Project Number 623-20-135
Bui ding Number
PARKING 1-2
l location JACI.. c. MONTCX'IME:RY VA t.EDK::Al.. CENTel I
Drawing Number . 1111tcNJRHDf!BDR,IIBCOCEE,(X74CJI
File details come from the government source that posted it. Updated .