36C25919R0086-0002001.pdf
PDF 4 MB Posted
- Attached to
- Renovate 7 East (VA-19-00024846)
- Solicitation number
- 36C25919R0086
About this file
36C25919R0086 0002 Architectural 7 East Pages 1 _11.pdf
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA OF WORKOUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONCOVER SHEET
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
100% BID DOCUMENTS
7 EAST RENOVATION
GI-000
100% BID DOCUMENTS
OKLAHOMA CITY VA HEALTH CARE SYSTEM
635-16-101
Sheet List
SHEET
SEQUENCE SHEET NUMBER SHEET NAME
[04] PLUMBING
25 P-000 PLUMBING LEGEND
26 PJD-101 MEDICAL GAS DEMO PLAN - 7TH FLOOR PLAN
27 PLD-101 PLUMBING WASTE DEMO PLAN - 7TH FLOOR PLAN
28 PPD-101 PLUMBING SUPPLY DEMO PLAN - 7TH FLOOR PLAN
29 PJ-101 MEDICAL GAS PLAN - 7TH FLOOR PLAN
30 PL-101 PLUMBING WASTE PLAN - 7TH FLOOR PLAN
31 PP-101 PLUMBING SUPPLY PLAN - 7TH FLOOR PLAN
32 P-301 PLUMBING RISER DIAGRAMS
33 P-302 PLUMBING RISER DIAGRAMS
34 P-501 PLUMBING DETAILS I
35 P-601 PLUMBING SCHEDULES I
[05] MECHANICAL
36 M-000 MECHANICAL LEGEND
37 MHD-101 MECHANICAL HVAC DEMO PLAN - 7TH FLOOR PLAN
38 MPD-101 MECHANICAL PIPING DEMO PLAN - 7TH FLOOR PLAN
39 MH-101 MECHANICAL HVAC PLAN - 7TH FLOOR PLAN
40 MP-101 MECHANICAL PIPING PLAN - 7TH FLOOR PLAN
41 M-501 MECHANICAL DETAILS I
42 M-502 MECHANICAL DETAILS II
43 M-601 MECHANICAL SCHEDULES I
44 M-701 MECHANICAL CONTROLS I
45 M-702 MECHANICAL CONTROLS II
[06] ELECTRICAL
46 E-000 ELECTRICAL LEGEND
47 ELD-101 ELECTRICAL LIGHTING DEMOLITION FLOOR PLAN - LEVEL 7
48 EPD-101 ELECTRICAL POWER DEMOLITION FLOOR PLAN - LEVEL 7
49 EYD-101 SPECIAL SYSTEMS DEMOLITION FLOOR PLAN - LEVEL 7
50 EL-101 ELECTRICAL LIGHTING FLOOR PLAN - LEVEL 7
51 EP-101 ELECTRICAL POWER FLOOR PLAN - LEVEL 7
52 EQ-101 MECHANICAL EQUIPMENT POWER FLOOR PLAN - LEVEL 7
53 EY-101 SPECIAL SYSTEMS FLOOR PLAN - LEVEL 7
54 EF-101 FIRE ALARM FLOOR PLAN - LEVEL 7
55 E-401 ELECTRICAL PARTIAL FLOOR PLANS - LEVEL 7 AND LEVEL 8
56 E-501 ELECTRICAL DETAILS
57 E-601 ELECTRICAL ONE-LINE DIAGRAM AND TECHNOLOGY RISER DIAGRAMS
58 E-602 ELECTRICAL AND TECHNOLOGY SCHEDULES
59 E-603 ELECTRICAL SCHEDULES
60 E-701 LIGHTING CONTROL DIAGRAMS
TOTAL SHEET COUNT: 60
Sheet List
SHEET
SEQUENCE SHEET NUMBER SHEET NAME
[01] GENERAL
1 GI-000 COVER SHEET
2 GI-001 GENERAL INFORMATION
3 GI-011 LIFE SAFETY PLAN
4 GI-100 VERTICAL/HORIZONTAL ASSEMBLIES
[02] ARCHITECTURAL
5 AD-101 DEMOLITION PLAN
6 AS-101 ARCHITECTURAL FLOOR PLAN
7 AS-102 DIMENSION FLOOR PLAN
8 AS-103 REFLECTED CEILING PLAN
9 AS-104 BID DEDUCT ALTERNATES
10 AS-400 ENLARGED PLANS I
11 AS-401 ENLARGED PLANS II
12 AS-402 ENLARGED PLANS III
13 AS-403 ENLARGED PLANS IV
14 AS-404 ENLARGED PLANS V
15 AS-405 INTERIOR ELEVATIONS
16 AS-406 INTERIOR ELEVATIONS
17 AS-407 MILLWORK SECTIONS & PLAN DETAILS
18 AS-408 PLAN DETAILS
19 AS-501 FF&E PLAN
20 AS-601 DOOR AND WINDOW SCHEDULES
21 AS-701 FINISH PLAN
[03] FIRE PROTECTION
22 F-000 FIRE PROTECTION LEGEND
23 FXD-101 FIRE SPRINKLER DEMO
24 FX-101 FIRE SPRINKLER
SITE LOCATION
AREA OF WORK
KEY PLAN
Revision # Date 02/18/2019
GENERAL NOTES
MATERIALS LEGENDAREA KEY PLAN SYMBOLS LEGEND
ARCHITECTURAL ABBREVIATIONS
FIXTURE MOUNTING HEIGHTS
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• NATIONAL ELECTRICAL CODE (NEC)
• INTERNATIONAL PLUMBING CODE (IPC)
• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• ASME BOILER AND PRESSURE VESSEL CODE
• ASME CODE FOR PRESSURE PIPING
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)
• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318) MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL
CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND NEW
LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT.
• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1- 2004.
• SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15 – 2007.
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION.
THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS
ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
CODES, STANDARDS, AND EXECUTIVE ORDERS
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
AT ACOUSTICAL CEILING TILE
AT (SP) ACOUSTICAL CEILING TILE (WITH SPRAYED PLASTIC
FINISH)
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES
ADC AUTOMATIC DOOR CLOSER
ADH ADHESIVE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFB ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
ALUM ALUMINUM
AR AS REQUIRED
ASB ASBESTOS
AWT ACOUSTICAL WALL TREATMENT
BAT BATTEN
BEV BEVEL
BLKT BLANKET
BM BEAM OR BENCHMARK
BOT BOTTOM
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BTWN BETWEEN
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CORNER BEAD
CBB CEMENTITIOUS BACKER BOARD
CCTV CLOSED CIRCUIT TELEVISION
CC CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CD CONSTRUCTION DOCUMENTS OR
CONTRACT DOCUMENTS
CEM CEMENT
CER CERAMIC
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CHFR CHAMFER
CJ CONSTRUCTION JOINT OR
CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE OR CONTINUOUS
CONTR CONTRACTOR
CORR CORRIDOR
CPRS COMPRESSIBLE
CPT CARPET
CR CARD READER
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTRL CONTROL
DBL DOUBLE
DC DIAPER CHANGE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DL DEAD LOAD
DR DOOR OR DRAIN
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR OR ELEVATION
EPY EPOXY FLOORING
EQ EQUAL
EQL EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESC ESCUTCHEON
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXT EXTINGUISHER
F FEMALE
FA FIRE ALARM
FAB FABRIC
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF&E FURNITURE, FIXTURE, & EQUIPMENT
FIN FINISH
FIN FLR FINISH FLOOR (ELEVATION)
FIN WD FINISH WOOD
FIXT FIXTURE
FL FLOORLINE
FLSHG FLASHING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FIX FLUORESCENT FIXTURE
FO FINISHED OPENING
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FR FIRE RATING, FIRE RESISTANCE, OR FRAME
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBER REINFORCED PLASTIC
FT FEET OR FOOT
FURR FURRING
FURN FURNISH OR FURNITURE
FV FIELD VERIFY
FWC FABRIC WALLCOVERING
GA GAGE
GALV GALVANIC OR GALVANIZED
GB GRAB BAR
GD GUARD
GDR GUARD RAIL
GL GLASS
GT GROUT
GWB GYPSUM WALLBOARD
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HDR HARDWARE
HM HOLLOW METAL
HDRL HANDRAIL
HORIZ HORIZONTAL
HS HEAT-STRENGTHENED (GLASS)
OR HIGH STRENGTH
HSD HAND SANITIZER DISPENSER
HT HEIGHT
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
KPL KICKPLATE
L ANGLE
LAM GL LAMINATED GLASS
LAV LAVATORY
LD BRG LOAD-BEARING
LF LINEAR FEET (FOOT)
LINO LINOLEUM
LT GA LIGHT GAUGE
LVR LOUVER
LVT LUXURY VINYL TILE
MAX MAXIMUM
MCB METAL CORNER BEAD
MD METAL DECK
MECH RM MECHANICAL ROOM
MEL MELAMINE
MEMB MEMBRANE
MF MILL FINISH
MFR REC MANUFACTURER'S RECOMMENDATIONS
MIN MINUTE OR MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MLWK MILLWORK
MO MASONRY OPENING
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTL METAL
MULL MULLION
MW MICROWAVE
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
O/O OUT TO OUT
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OD OUTSIDE DIMENSION OR
OUTSIDE DIAMETER
OFF OFFICE
OH DR OVERHEAD (COILING) DOOR
OPP OPPOSITE
P PAINT
PC POLISHED CONCRETE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLYWD PLYWOOD
PMTL PAINTED METAL
PNL PANEL
PR PAIR
PT PORCELAIN TILE
PTB PORCELAIN TILE BASE
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
QUAL QUALITY
R RADIUS OR RISER
RB RUBBER BASE
RB HK ROBE HOOK
RBR RUBBER
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REINF REINFORCE
REQD REQUIRED
RES POURED RESINOUS FLOORING
RESIL RESILIENT
RET RETURN
REV REVISION
RM ROOM
RO ROUGH OPENING
RSF RESILIENT SHEET FLOORING (CHEMICALLY WELDED
SEAMS)
RV ROOF VENT
S SEALED CONCRETE
SAT SUSPENDED ACOUSTICAL TILE
SC HIGH BUILD GLAZED COATING (SPECIALTY COATING)
SCD TOILET SEAT COVER DISPENSER
SCHED SCHEDULE
SCWD SOLID CORE WOOD DOOR
SD SOAP DISPENSER
SF SQUARE FOOT (FEET)
SHT SHEET
SHV SHELVING
SIM SIMILAR
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SERVICE SINK
SST STAINLESS STEEL
ST STAIRS
STRUCT STRUCTURAL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STNLS STAINLESS
STOR STORAGE
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
T TREAD
T&G TONGUE AND GROOVE
TB TOWEL BAR
TD TOWEL DISPENSER
TEL TELEPHONE
THRES THRESHOLD
THRU THROUGH
TMPD GL TEMPERED GLASS
TO TOP OF
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWER RACK
TYP TYPICAL
UCD UNDERCUT DOOR
UNO UNLESS NOTED OTHERWISE
UR URINAL
UTIL UTILITY
VAR VARIES
VC VA PROVIDED / CONTRACTOR INSTALLED
VV VA PROVIDED / VA INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSITCAL TILE
VR VAPOR RETARDER
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WALLCOVERING (VINYL COATED FABRIC)
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WD WOOD
WDW WINDOW
WFAB WALL FABRIC
WR WASTE RECEPTACLE
WSCT WAINSCOT
WSF WELDED SEAM RESILIENT FLOORING (HEAT
WELDED WITH ROD)
X BRACE CROSS BRACE
YD YARD
ENERGY REQUIREMENTS
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN
INTENT OF THE ENTIRE DOCUMENT SET.
2. THE DEMOLITION DRAWINGS ARE DEEMED SCHEMATIC. CONTRACTOR RESPONSIBLE FOR FIELD VERIFYING EXISTING DEMOLITION WORK PRIOR TO
SUBMISSION OF PROPOSAL.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION WORK. PROVIDE DUST PROOFING
ENCLOSURES TO SEPARATE WORK AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISITING SURFACES AND CONDITIONS TO REMAIN IN PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE
OCCUR, PATCH AND REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO
ADDITIONAL COST TO THE OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT PARTICULATE MATERIAL FROM EXHAUSTING INTO
SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE AND OPERATIONAL SYSTEMS.
INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS, BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE, EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60 CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED, IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF THE MEDICAL CENTER.
INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS.
SCHEDULE INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING THE CONSTRUCTION
SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF
THE CONSTRUCTION DOCUMENTS.
ROOM NAME,
NUMBER AND
SQUARE FEET
A101
X'-X"
COLUMN GRID
KEYNOTE
WALL OR PARTITION TYPE
NORTH ARROW
ELEVATION INDICATOR,
INTERIOR/EXTERIOR
BUILDING SECTION
INDICATOR
ELEVATION INDICATOR
BREAK, STRAIGHT (SEE
SECTION INDICATORS,
BUILDING, WITH BREAK
STANDARDS)
DETAIL INDICATOR
ELEVATION INDICATOR
FOR SIMILAR CONDITIONS
DIMENSION LINE
CENTER LINE
FIRE EXTINGUISHER CABINET
1 1/2"
MATCH LINE
NORTH
1A
A
A
FEC
FE FIRE EXTINGUISHER
CORNER GUARDCG
A101
DETAIL INDICATOR
1 / A101
SIM
Room Name
150 SF
A101
SIM
A101
SIM
WINDOW TYPE1t
1 / A101
SIM
CLEAR FLOOR SPACE
30"
C L E
A R
F L O
O R
S P
A C
E
CLEAR FLOOR SPACE
72"
C L E
A R
F L O
O R
S P
A C
E
18"
M A
X
M A
X
M A
X
M
IN
18" MIN
1. GENERAL CONTRACTOR TO PROVIDE
METAL STUD OR PLATE BLOCKING FOR
ALL WALL MOUNTED ACESSORIES,
FIXTURES, AND EQUIPMENT.
2. SPECIFIED MAXIMUMS ARE MEASURED
FROM AFTER FINISHED FLOOR TO THE
OPERABLE PART OF THE FIXTURE.
3. FIXTURES SHOWN ARE
REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO
SPECIFICATIONS FOR FIXTURE TYPES
USED IN THIS PROJECT.
4. FIXTURES MAY OVERLAP WAINSCOT.
WHERE APPLICABLE, BACKING TO BE
PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH
SCHEDULED WALL FINISH.
6" MAX
M
IN
SHOWER
TURNING RADIUS BARRIATRIC
TURNING RADIUS
PAPER TOWEL
DISPENSER
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
M A
X
SOAP
DISPENSER
M A
X
M A
X
17" MIN
M
IN
M A
X
M A
X
18" MIN
8" MIN
WALL
LAVATORY
WITH APRON
M A
X
18" MIN
URINAL
WALL
18"
36" MIN
12" 42" MIN 12"
54" MIN
M
IN
WALLWALL
M A
X
WALL HOOK
CLOCK
WALL
ø 60" ø 72"
FINISHED
FLOOR
FINISHED
FLOOR
M A
X
FIRE
EXTINGUISHER
CABINET
WEIGHT > 40LBS
M A
X
FIRE
EXTINGUISHER
CABINET
WEIGHT < 40LBS
M
ID
P O
IN
T
A T
M A
X
DRY ERASE
BOARD
M A
X
WALL PHONE
M A
X
ADJUSTABLE
COMPUTER
WORKSTATION
ADA TOILET AND GRAB BARS
*KEYBOARD REQUIRED TO BE
ACCESSIBLE AT 36"
ADJUSTABLE
TRACK
VA STANDARD
TURNING RADIUS
ø 66"
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
BRICK
CMU
STONE
FIBERGLASS SEMI RIGID
INSULATION
FIBERGLASS BATT
INSULATION
MINERAL WOOL SEMI RIGID
INSULATION
EXPANDED POLYSTYRENE
RIGID INSULATION
EXTRUDED POLYSTYRENE
RIGID INSULATION
POLYISOCYANURATE RIGID
INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR
CEMENT BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
COVER BOARD
SPRAY-APPLIED CLOSED
CELL INSULATION
IECC 2012 EDITION
BUILDING LOCATION: OKLAHOMA CITY, OKLAHOMA
CLIMATE ZONE (FIGURE C301.1): ZONE 3
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES USED FOR HEATING AND COOLING LOAD CALCULATIONS SHALL BE A MAXIMUM OF 72 DEGREES FAHRENHEIT AND MINIMUM OF 75 DEGREES FAHRENHEIT FOR COOLING.
BUILDING ENVELOPE REQUIREMENTS (C402):
OPAQUE THERMAL ENVELOPE REQUIREMENTS (TABLE C402.1.3):
ROOFS
INSULATION ENTIRELY ABOVE DECK:
METAL BUILDINGS (W/ R-5 THERMAL BLOCKS):
ATTIC AND OTHER:
WALLS, ABOVE GRADE
MASS:
METAL BUILDING:
METAL FRAMED:
WOOD FRAMED AND OTHER:
WALLS, BELOW GRADE
BELOW-GRADE WALL:
FLOORS
MASS:
JOIST/FRAMING:
SLAB-ON-GRADE
UNHEATED SLABS:
HEATED SLABS:
OPAQUE DOORS
SWINGING:
ROLL-UP OR SLIDING:
FENESTRATION (TABLE C402.4):
VERTICAL FENESTRATION
U-FACTOR
FIXED FENESTRATION:
OPERABLE FENESTRATION:
ENTRANCE DOORS:
SHGC
SHGC
SKYLIGHTS
U-FACTOR
SHGC
MAXIMUM AREA (C402.3.1)
N/A
REQUIRED AS DESIGNED
N/A N/A N/A
N/A N/A R-13 + R-7.5ci N/A
N/A
N/A N/A
N/A N/A
U-0.61 N/A
N/A N/A N/A
N/A
N/A N/A
AREA OF WORKOUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONGENERAL INFORMATION
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
GI-001
100% BID DOCUMENTS
635-16-101
LIFE SAFETY LEGEND
1 OCCUPANT LOAD
SPACE NOT OCCUPIED
BUILDING EXIT
PROTECTED AREA ENCLOSED WITH
SMOKE PARTITIONS
EGRESS PATH
1 HOUR FIRE
2 HOUR FIRE
3 HOUR FIRE
4 HOUR FIRE
1 HOUR FIRE / SMOKE
2 HOUR FIRE / SMOKE
3 HOUR FIRE / SMOKE
4 HOUR FIRE / SMOKE
FACP
FEC
FIRE ALARM CONTROL PANEL
FIRE EXTINGUISHER CABINET
FIRE RATED WALL SYMBOLS
NFPA 101-2015 EDITION
PROJECT AREA: 18,838 SF INTERIOR REMODEL OF 7TH FLOOR
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
CONSTRUCTION TYPE: (TABLE A.8.2.1.2): TYPE II (000)
OCCUPANCY CLASSIFICATION: EXISTING HEALTHCARE OCCUPANCY (CH. 19)
TOTAL OCCUPANT LOAD: 32 OCCUPANTS (TABLE 7.3.1.2)
• MIN. TYPICAL DOOR WIDTH = 32" MIN.
• MIN. PATIENT BED DOOR WIDTH = 70" MIN.
• MIN. WIDTH OF EGRESS COMPONENTS (32 OCC. X .2"/OCC.) = 6.4" (32" MIN. PER 19.2.3.6)
FIRE RESISTANCE RATINGS (TABLE A.8.2.1.2):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK,
EXTERIOR NON-BEARING WALLS, AND INTERIOR NON-BEARING WALLS.
OCCUPANT LOADS (TABLE 7.3.1.2):
• ASSEMBLY (UNCONCENTRATED) = 15 SF/PERSON
• BUSINESS AREA = 100 SF/PERSON
• INPATIENT TREATMENT AREAS = 240 SF/PERSON
MAXIMUM COMMON PATH OF TRAVEL: 100' (18.2.5.3)
MAXIMUM TRAVEL DISTANCE: 200' (19.2.6.2.1 & 19.2.6.2.2)
CORRIDOR MINIMUM FIRE RATING: 1/2 HR (19.3.6.2.2)
FIRE ALARM SYSTEM:
- REQUIRED/PROVIDED MANUAL SYSTEM.
B
B
C
C
D
D
E
E
F
F
G
G
I
I
J
J
K
K
8 8
6 6
7 7
5 5
4 4
106 SF
ANTE ROOM
714A
261 SF
PATIENT ROOM
(ISO)
273 SF
PATIENT ROOM
62 SF
PATIENT TOILET
717R
284 SF
PATIENT ROOM
56 SF
PATIENT TOILET
718R
83 SF
PATIENT TOILET
714R
39 SF
CLEAN SUPPLY
264 SF
PATIENT ROOM
59 SF
PATIENT TOILET
715R
57 SF
PATIENT TOILET
712R
301 SF
PATIENT ROOM
268 SF
PATIENT ROOM
(BARIATRIC)
71 SF
PATIENT TOILET
710R
38 SF
OXYGEN
STORAGE
50 SF
TOILET
217 SF
NOURISHMENT /
WAITING
138 SF
CONSULT
305 SF
STAFF LOUNGE
NURSE WORK
ROOM
175 SF
MED ROOM & IV
STORAGE
128 SF
STORAGE
51 SF
PATIENT TOILET
724R
51 SF
PATIENT TOILET
722R
263 SF
PATIENT ROOM
99 SF
CLEAN UTILITY
35 SF
CRASH CART
ALCOVE
261 SF
PATIENT ROOM
51 SF
PATIENT TOILET
725R
51 SF
PATIENT TOILET
723R
262 SF
PATIENT ROOM
66 SF
HAC
83 SF
SOILED UTILITY
263 SF
PATIENT ROOM
93 SF
CLEAN LINEN
R 75' - 0
R 75' - 0"
1 1
1 1
1 1 1
1 1
137 SF
NURSE MANAGER
OFFICE
T R
A V
E L
D
IS
T A
N C
E
TRAVEL DISTANCE
83' - 9"
T R
A V
E L
D
IS
T A
N C
E
TRAVEL DISTANCE
84' - 4"
142 SF
INFO. TECH.
L
L
42 SF
NURSE ALCOVE
147 SF
NURSE STATION
708 28 SF
STORAGE
51 SF
STAFF TOILET
611 SF
CORRIDOR
979 SF
CORRIDOR
156 SF
CORRIDOR
33 SF
ELEC. CLST
A
A
7 SF
STORAGE
FEC
FEC
33343536373839 40
52 SF
EXISTING
WOMEN'S
RESTROOM
AREA OF WORK
OUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONLIFE SAFETY PLAN
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
GI-011
100% BID DOCUMENTS
635-16-101
N
1/8" = 1'-0"
LIFE SAFETY PLAN
GENERAL NOTES:
1. NOT ALL PARTITION TYPES SHOWN HERE MAY BE USED. REFER TO PLANS
FOR LOCATION AND TYPES OF EACH PARTITION.
2. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON
BOTH SIDES OF ALL FIRE AND SMOKE WALLS DESIGNATING THE PARTITION
RATING INDICATED ON THE LIFE SAFETY PLAN.
3. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS
OF ALL WALL TILE. PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN
LIEU OF GWB AT ALL SCHEDULED TILE LOCATIONS. UNLESS NOTED
OTHERWISE, TILE SHALL BE INSTALLED PER TILE COUNCIL OF AMERICA
LATEST STANDARDS FOR EACH TYPE OF BACKING MATERIAL REPRESENTED
IN WALL/PARTITION.
4. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GWB WHICH
EXTENDS A MINIMUM OF 6" ABOVE THE SUSPENDED CEILING UNLESS SHOWN
AND/OR NOTED OTHERWISE BY THE ARCHITECT.
5. REFER TO STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL
CONDITIONS IN REGARDS TO STRUCTURAL REQUIREMENTS.
6. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS,
JAMBS, ETC. SHALL ALIGN ACROSS VOIDS AND JOINTS.
7. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS
(UNLESS NOTED OTHERWISE) WHERE DRYWALL CONTINUES ABOVE CEILING
AND ABOVE THE CEILING LEVEL UP TO THE STRUCTURE ABOVE. ALL GYPSUM
BOARD RETURNS SHALL HAVE CORNER BEADS MINIMUM FLOOR TO CEILING.
ALL PENETRATIONS IN DRYWALL CONSTRUCTION ABOVE FINISHED CEILING
SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND FIRE
STOPPING TAPE/CAULK AT ALL RATED PARTITIONS.
8. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP
TO THE UNDERSIDE OF THE DECK STRUCTURE ABOVE. ALL PLUMBING
CHASES UNLESS OTHERWISE NOTED, SHALL EXTEND ABOVE THE HIGHEST
ADJOINING CEILING AND BE BRACED TO STRUCTURE.
9. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF
STRUCTURE SHALL BE SUPPORTED BY TOP CHORD OF STRUCTURAL JOISTS
AND NOT FROM THE METAL DECK.
10. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING
IN WALLS/PARTITIONS. ALL WOOD BLOCKING IS TO BE FIRE RETARDANT
TREATED.
11. IMPACT RESISTANT GWB, WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND
BEHIND LOCKERS.
12. SEAL THE TOP AND BOTTOM OF WALL AS WELL AS ALL PENETRATIONS
WHERE SMOKE PARTITIONS ARE DESIGNATED ON THE LIFE SAFETY PLAN TO
ELIMINATE THE PASSAGE OF SMOKE.
13. ALL PARTITIONS THAT HOST PLUMBING FIXTURES SHALL RECEIVE MOLD /
MOISTURE RESISTANT GWB IN LIEU OF REGULAR GWB.
SEAL TO STRUCTURAL
DECK ABOVE
TAPE AND BED GYP. BD.
ONLY ABOVE CEILING
EACH SIDE
CEILING MATERIAL
AS SCHEDULED
WALL FINISH AS
SCHEDULED
SOUND ATTENUATION
FIRE BLANKETS AS REQ'D
5/8" GYP. BD. EACH
SIDE OF METAL
STUDS AT 16" O.C.
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
LINE OF STRUCTURAL DECK
TAPE AND BED GYP. BD.
ONLY ABOVE CEILING
EACH SIDE
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
SOUND ATTENUATION
BATTS AS REQ'D
5/8" GYP. BD. EACH
SIDE OF METAL
STUDS AT 16" O.C.
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
1 LAYER 5/8" GYP. BD. ON EACH SIDE OF 3 5/8" METAL STUDS AT 16"
O.C. EXTEND FROM FIN. FLR. TO DECK.
1 LAYER 5/8" GYP. BD. ON EACH SIDE OF 6" METAL STUDS AT 16" O.C.
EXTEND FROM FIN. FLR. TO DECK.
1 LAYER 5/8" GYP. BD. ON EACH SIDE OF 3 5/8" METAL STUDS AT 16" O.C.
W/ SOUND ATTENUATION BATTS EXTEND FROM FIN. FLR. TO DECK.
(STC 45)
1 LAYER 5/8" GYP. BD. ON EACH SIDE OF 6" METAL STUDS AT 16" O.C.
W/ SOUND ATTENUATION BATTS EXTEND FROM FIN. FLR. TO DECK.
(STC 45)
LINE OF STRUCTURAL DECK
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
5/8" GYP. BD. ONE
SIDE OF METAL
STUDS AT 16" O.C.
BASE AND FLOORING
AS SCHEDULED
1 LAYER 5/8" GYP. BD. ON ONE SIDE OF 3 5/8" METAL STUDS AT 16" O.C.
EXTEND TO BOTTOM OF DECK SEAL TO DECK. ALL JOINTS TAPED
1 LAYER 5/8" GYP. BD. ON ONE SIDE OF 6" METAL STUDS AT 16" O.C.
EXTEND TO BOTTOM OF DECK SEAL TO DECK. ALL JOINTS TAPED
1 LAYER 5/8" GYP. BD. ON ONE SIDE OF 3 5/8" METAL STUDS AT 16" O.C.
EXTEND TO 6" ABOVE FINISHED CEILING. ALL JOINTS TAPED
5/8" TYPE 'X' GYP. BD. ON EACH SIDE OF 3 5/8" METAL STUDS AT 16"
O.C. W/ SOUND ATTENUATION FIRE BLANKETS EXTEND & SEAL TO
DECK ABOVE. RATED SMOKE & ONE HOUR. UL #U465 (STC 45)
5/8" TYPE 'X' GYP. BD. ON EACH SIDE OF 6" METAL STUDS AT 16" O.C.
W/ SOUND ATTENUATION FIRE BLANKETS EXTEND & SEAL TO DECK
ABOVE. RATED SMOKE & ONE HOUR. UL #U465 (STC 45)
TYPE 1
(1 HR RATED)
SUFFIX
A
B
C
D
DETAILS
TYPE 3
(NON RATED)
SUFFIX
A
B
C
D
DETAILS
TYPE 4
(NON RATED)
SUFFIX
A
B
C
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
LINE OF STRUCTURAL DECK
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
1 LAYER 3/4" FIRE RETARDANT PLYWOOD ON ONE SIDE OF 3 5/8" METAL
STUD FRAMING AT 16" O.C. WITH 1 LAYER TYPE 'X' GYP. BD. ON OPP.
SIDE. EXTEND TO BOTTOM OF DECK & SEAL TO DECK.
TYPE 5
(NON RATED)
SUFFIX
A
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
3/4" PLYWOOD
SHEATHING
SEAL TO STRUCTURAL
DECK ABOVE
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
2 LAYERS 5/8" GYP. BD.
ON EACH SIDE OF METAL
STUDS AT 16" O.C.
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
2 LAYERS 5/8" GYP. BD. ON EACH SIDE OF 3 5/8" METAL STUDS AT 16"
O.C. EXTEND TO BOTTOM OF DECK SEAL TO DECK. ALL JOINTS TAPED.
UL #U404
2 LAYERS 5/8" GYP. BD. ON EACH SIDE OF 6" METAL STUDS AT 16"
O.C. EXTEND TO BOTTOM OF DECK SEAL TO DECK. ALL JOINTS
TAPED. UL # U404
TYPE 2
(2 HR RATED)
SUFFIX
A
B
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
SOUND ATTENUATION
BATTS AS REQ'D
-B
5/8" TYPE 'X' GYP. BD.
ONE SIDE OF METAL
STUDS AT 16" O.C.
LINE OF STRUCTURAL DECK
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
5/8" GYP. BD. ON
7/8" HAT CHANNEL
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P 6"
1 LAYER 5/8" GYP. BD OVER 7/8" HAT CHANNEL. EXTEND TO 6" ABOVE
FINISHED CEILING
TYPE 6
(NON RATED)
SUFFIX
A
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
LINE OF STRUCTURAL DECK
CEILING MATERIAL AS
SCHEDULED
HEAD WALL ASSEMBLY
5/8" GYP. BD. ON EACH
SIDE OF 3 5/8" METAL
STUD FRAMING AS
REQUIRED
BASE AND FLOORING
AS SCHEDULED
1 LAYER 5/8" GYP. BD ON EACH SIDE OF 3 5/8" METAL STUD FRAMING W/
HEADWALL ASSEMBLY ON ONE SIDE. EXTEND FROM FIN. FLR. TO DECK.
TYPE 7
(NON RATED)
SUFFIX
A
D
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
C
1 LAYER 5/8" GYP. BD AND HEADWALL ASSEMBLY ON ONE SIDE OF 3
5/8" METAL STUD FRAMING. EXTEND FROM FIN. FLR. TO DECK.B
E
1 LAYER 5/8" GYP. BD. ON EACH SIDE OF 3 5/8" METAL STUDS AT 16"
O.C. EXTEND TO 6" ABOVE FINISHED CEILING-- -- -------
1 LAYER 5/8" GYP. BD ON EACH SIDE OF 3 5/8" METAL STUD FRAMING W/
HEADWALL ASSEMBLY ON ONE SIDE W/ SOUND ATTENUATION BATTS.
EXTEND FROM FIN. FLR. TO DECK. (STC 45)
1 LAYER 3/4" FIRE RETARDANT PLYWOOD OVER 7/8" HAT CHANNEL ON
EXISTING WALL ASSEMBLY. EXTEND TO 6" ABOVE FINISHED CEILING.
SEAL TO STRUCTURAL
DECK ABOVE
TAPE AND BED GYP. BD.
ONLY ABOVE CEILING
EACH SIDE
CEILING MATERIAL
AS SCHEDULED
WALL FINISH AS
SCHEDULED
SOUND ATTENUATION
FIRE BLANKETS AS REQ'D
5/8" GYP. BD. EACH
SIDE OF METAL
STUDS AT 16" O.C.
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P
TYPE 8
(NON RATED)
SUFFIX DETAILS
TILE ON 5/8" CEMENTITIOUS BACKER BOARD ON ONE SIDE OF 3 5/8"
MTL STUDS AT 16" O.C. AND 5/8" GYP. BD. ON THE OPP. SIDE.
EXTEND FROM FIN. FLR. TO DECK.
TILE ON 5/8" CEMENTITIOUS BACKER BOARD ON ONE SIDE OF 3 5/8"
MTL STUDS AT 16" O.C. W/ SOUND BLANKETS AND 5/8" GYP. BD. ON
THE OPP. SIDE. EXTEND FROM FIN. FLR. TO DECK. (STC 45)
A
B
C
D
E
5/8" CEMENTITIOUS
BACKER BOARD
FLUID-APPLIED
MOISTURE BARRIER
TILE WALL FINISH
AS SCHEDULED
LINE OF STRUCTURAL DECK
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
TILE FINISH AS
SCHEDULED
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P 6"
TYPE 9
(NON RATED)
SUFFIX
A
B
C
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
FINISH ON 5/8" CEMENTITIOUS BACKER BOARD ON 3 5/8" MTL
STUDS AT 16" O.C. EXTEND TO 6" ABOVE FINISHED CEILING. ALL
JOINTS TAPED
5/8" CEMENTITIOUS BACKER
BOARD ON 3 5/8" METAL
STUD FRAMING
LINE OF STRUCTURAL DECK
CEILING MATERIAL AS
SCHEDULED
WALL FINISH AS
SCHEDULED
TILE FINISH AS
SCHEDULED
BASE AND FLOORING
AS SCHEDULED
C E
IL
IN
G H
E
IG
H T
R E
: R C
P 6"
FINISH ON 5/8" CEMENTITIOUS BACKER BOARD OVER 7/8" HAT
CHANNEL. EXTEND TO 6" ABOVE FINISHED CEILING.
TYPE 10
(NON RATED)
SUFFIX
A
DETAILS
F
LO
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E A
B O
V E
5/8" CEMENTITIOUS BACKER
BOARD ON 7/8" HAT CHANNEL
FLUID-APPLIED
MOISTURE BARRIER FLUID-APPLIED
MOISTURE BARRIER
TILE FINISH ON 5/8" CEMENTITIOUS BACKER BOARD ON ONE SIDE OF
3 5/8" MTL STUD AT 16" O.C. W/ 5/8" GYP. BD. & HEADWALL ASSEMBLY
ON OPP. SIDE W/ SOUND ATTENUATION BATTS. EXTEND FROM FIN.
FLR. TO DECK. (STC 45)
5/8" TYPE 'X' GYP. BD. ONE SIDE OF 3 5/8" MTL STUDS AT 16" O.C. W/
SOUND BLANKETS. TILE ON 5/8" CEMENTITIOUS BOARD ON OPP. SIDE.
EXTEND & SEAL TO DECK ABOVE. RATED SMOKE & ONE HOUR. (STC 45)
5/8" TYPE 'X' GYP. BD. ONE SIDE OF 3 5/8" MTL STUDS AT 16" O.C. W/
SOUND BLANKETS. TILE ON 5/8" CEMENTITIOUS BOARD ON OPP. SIDE.
EXTEND & SEAL TO DECK ABOVE. RATED SMOKE & ONE HOUR. (STC 45)
ROOMCORRIDOR
TILE FINISH ON 5/8"
CEMENTITIOUS BACKER
BOARD WHERE APPLICABLE
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONVERTICAL/HORIZONTAL
ASSEMBLIES
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
GI-100
100% BID DOCUMENTS
635-16-101
STAIR - 1
STAIR 9
CHASE
STAIR - 5
ELEVATOR
P-4
ELEVATOR
P-5
ELEVATOR
P-6
B
B
C
C
D
D
E
E
F
F
G
G
I
I
J
J
K
K
8 8
6 6
7 7
5 5
4 4
1 1
1 1
1 1
2 2
2 2
44 4
4 4
5 7
L
L
A
A
USE EXISTING DOOR AS
CONSTRUCTION BARRIER
WALK-OFF MAT TO BE 6"
WIDER THAN DOOR, TYP.
CONSTRUCT DUST BARRIER AND
TEMP. DOOR TO DECK. DO NOT
INTERFERE WITH ADJACENT ROOM
WALK-OFF MAT TO BE 6"
WIDER THAN DOOR, TYP.
CONSTRUCT DUST BARRIER AND
TEMP. DOOR TO DECK. DO NOT
INTERFERE WITH ADJACENT ROOM
WALK-OFF MAT TO BE 6"
WIDER THAN DOOR, TYP.
REMOVE EXISTING FLOOR
COVERING STARTING HERE
REMOVE EXISTING FLOOR
COVERING IN CORRIDOR
STARTING HERE
PREPARE TELECOM AND
IT EQUIPMENT FOR
RELOCATION TO ROOM
730. RE: ELECTRICAL
USE EXISTING DOOR AS
CONSTRUCTION BARRIER
WALK-OFF MAT TO BE 6"
WIDER THAN DOOR, TYP.
PREPARE ABOVE CEILING
SLAB FOR PLUMBING
WORK, REF: PLUMBING10
FIXTURES TO REMAIN
GENERAL DEMOLITION NOTES
1. DRAWINGS TO BE TAKEN AS PART OF A
COMPLETE DOCUMENT SET. CONTRACTOR TO
CONFIRM ALL ITEMS REQUIRED TO BE
DEMOLISHED AND EXTENT OF DEMOLITION
BASED UPON THE OVERALL INTENT OF THE
ENTIRE DOCUMENT SET.
2. THE DEMOLITION DRAWINGS ARE DEEMED
SCHEMATIC. CONTRACTOR RESPONSIBLE FOR
FIELD VERIFYING EXISTING DEMOLITION WORK
PRIOR TO SUBMISSION OF PROPOSAL.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF
WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL
TIMES. ERECT BARRICADES AND WARNING
SIGNS TO DIVERT AND WARN PASSERS-BY OF
THE CONSTRUCTION WORK. PROVIDE DUST
PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES. VA TO
APPROVE BARRIER LOCATIONS; BARRIERS TO
BE CONSTRUCTED PER VA STANDARDS.
4. DURING DEMOLITION, PROVIDE PROTECTION
FOR ALL EXISTING SURFACES AND CONDITIONS
TO REMAIN IN PLACE DURING THE RENOVATION
WORK. SHOULD ANY DAMAGE OCCUR, PATCH
AND REPAIR TO MATCH EXISTING ADJACENT
FINISHES. SUBSTANTIAL DAMAGES TO BE
REPORTED TO THE VA PROJECT MANAGER.
5. ANY DAMAGE CAUSED TO THE BUILDING OR
OWNER EQUIPMENT SHALL BE REPAIRED OR
REPLACED BACK TO ITS ORIGINAL CONDITIONS
AT NO ADDITIONAL COST TO THE OWNER.
6. ALL ITEMS INDICATED WITH A DASHED LINE
SHALL BE REMOVED IN THEIR ENTIRETY
INCLUDING RELATED COMPONENTS
7. REMOVAL OF MECHANICAL, ELECTRICAL, AND
PLUMBING SHOULD BE LIMITED TO WHAT IS
NECESSARY FOR SAFE REMOVAL OF THE
INDICATED WALL OR CEILING. APPROPRIATE
LIGHT FIXTURES SHALL BE TEMPORARILY
SUSPENDED TO PROVIDE ADEQUATE LIGHTING
LEVELS FOR CONSTRUCTION.
8. CONTRACTOR TO DEMO ALL FIXTURES,
CEILINGS, MECHANICAL, PLUMBING, AND
ELECTRICAL AS REQUIRED TO COMPLETE THE
SCOPE OF WORK OUTLINED WITHIN THE
CONSTRUCTION DOCUMENTS.
9. REMOVE ALL EXISTING FLOOR MATERIALS AND
MASTIC/ ADHESIVES WITHIN THE AREA OF
WORK. PREPARE FLOOR TO ACCEPT NEW
FINISHES.
10. STAIRWELL 5 NOT IN WORK AREA.
11. HEPA FILTER PORTABLE AIR FILTRATION
MACHINES TO BE USED TO MITIGATE THE
MIGRATION OF DUST DURING CONSTRUCTION
12. REFER TO PLUMBING DEMO PLANS FOR
EXISTING PLUMBING FIXTURES FOR
REFERENCE ONLY.
13. COLUMN NUMBERS FOR REFERENCE ONLY.
14. IF THE EXECUTION OF THIS WORK REQUIRES
THE DISTURBING OF ANY SUBSTANCE WHICH
APPEARS TO BE ASBESTOS OR WHICH MAY
CONTAIN ASBESTOS FIBER, NOTIFY THE
OWNER BEFORE CONTINUING WORK AT THE
SUSPECT LOCATION. ANY MATERIAL TESTING
POSITIVE SHALL BE REMOVED BY THE OWNER
BEFORE WORK CONTINUES.
15. EXISTING CONDITIONS SHOWN WERE DERIVED
FROM OWNER FURNISHED DRAWINGS AND
FIELD OBSERVATIONS. SOME BUILDING
FEATURES AND MEP SYSTEMS ARE NOT
SHOWN FOR CLARITY. FIELD VERIFY BUILDING
CONSTRUCTION. FIELD VERIFY THE LOCATION,
SIZE AND QUANTITY OF ALL EQUIPMENT.
16. ALL EXISTING WALLS THAT ARE WITHIN THE
PROJECT SCOPE SHALL RECEIVE THE STEPS
OUTLINED IN DEMOLITION KEYNOTE #7, UNLESS
NOTED OTHERWISE, ON THE SIDE OF THE WALL
CONTAINED WITHIN THE PROJECT SCOPE.
17. DEMOLITION AND CONSTRUCTION ACTIVITIES
TO CONFORM WITH VA ICRA CLASS IV
REQUIREMENTS.
DEMO EXISTING WALL CONSTRUCTION IN ITS
ENTIRETY
DEMO & DISCARD EXISTING DOOR & FRAME 2
REMOVE EXISTING FLOORING IN ITS ENTIRETY:
CLEAN & PREPARE SURFACE FOR NEW
FLOORING PER RENOVATION PLAN
DEMOLITION KEYNOTES
DEMO CEILING, LIGHT FIXTURES, DIFFUSERS,
ELECTRICAL THROUGHOUT AREA OF WORK
DEMO EXISTING PLUMBING FIXTURES5
DEMO EXISTING CASEWORK AND MILLWORK IN
ITS ENTIRETY
REMOVE EXISTING GYP. FINISH AND PREPARE
WALL TO RECEIVE NEW SHEATHING AND FINISH.
REMOVE EXISTING FINISH AS NEEDED TO INSTALL
NEW PLUMBING AND PREPARE WALL TO RECEIVE
NEW FINISH.
REMOVE AND REUSE EXISTING PNEUMATIC TUBE
EQUIPMENT. PROVIDE ALL NECESSARY ITEMS
FOR REINTEGRATION TO EXISTING SYSTEM. RE:
PLUMBING
DEMO EXISTING ACT AND GYP. CEILING. REMOVE
AND REUSE EXISTING LIGHT FIXTURES, DIFFUSERS,
ELECTRICAL THROUGHOUT AREA OF WORK.
AREA OF WORK
OUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONDEMOLITION PLAN
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
AD-101
100% BID DOCUMENTS
635-16-101
N
1/8" = 1'-0"
DEMO ARCHITECTURAL FLOOR PLAN
GENERAL FLOOR PLAN NOTES
1. ALL DOOR FRAMES TO BE LOCATED 2" FROM
OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. REFER TO DOOR SCHEDULE & DETAILS SHEET
FOR DOOR INFORMATION.
3. REFER TO GLAZING ELEVATIONS & DETAILS
SHEET FOR WINDOW INFORMATION.
4. ALL NEW WALLS ARE DIMENSIONED TO
CENTERLINE OF METAL STUD, UNLESS NOTED
OTHERWISE.
5. ALL EXISTING WALLS DIMENSION TO FINISH
FACE, UNLESS NOTED OTHERWISE.
6. FINISH FACE OF NEW WALLS TO ALLIGN WITH
FINISH FACE OF EXISTING WALLS UNLESS
NOTED OTHERWISE.
7. FURR AROUND ALL COLUMN PROTRUSIONS AS
NEEDED UNLESS NOTED OTHERWISE.
106 SF
ANTE ROOM
714A
261 SF
PATIENT ROOM
(ISO)
273 SF
PATIENT ROOM
62 SF
PATIENT
TOILET
717R
284 SF
PATIENT ROOM
56 SF
PATIENT
TOILET
718R83 SF
PATIENT
TOILET
714R
39 SF
CLEAN SUPPLY
264 SF
PATIENT ROOM
59 SF
PATIENT
TOILET
715R
57 SF
PATIENT
TOILET
712R
301 SF
PATIENT ROOM
268 SF
PATIENT ROOM
(BARIATRIC)
71 SF
PATIENT TOILET
710R
38 SF
OXYGEN
STORAGE
50 SF
TOILET
217 SF
NOURISHMENT /
WAITING
138 SF
CONSULT
305 SF
STAFF LOUNGE
NURSE WORK
ROOM
175 SF
MED ROOM & IV
STORAGE
128 SF
STORAGE
51 SF
PATIENT
TOILET
724R
51 SF
PATIENT
TOILET
722R
263 SF
PATIENT ROOM
99 SF
CLEAN UTILITY
35 SF
CRASH CART
ALCOVE
261 SF
PATIENT ROOM
51 SF
PATIENT
TOILET
725R
51 SF
PATIENT
TOILET
723R
262 SF
PATIENT ROOM
66 SF
HAC
83 SF
SOILED UTILITY
263 SF
PATIENT ROOM
93 SF
CLEAN LINEN
AS-400
B
B
C
C
D
D
E
E
F
F
G
G
I
I
J
J
K
K
8 8
6 6
7 7
5 5
4 4
AS-400
AS-401
AS-401
AS-402
AS-403
AS-402
AS-402
AS-403
AS-403
AS-404
AS-404
AS-404
AS-404
AS-404
AS-404
AS-404
.1
720.1
R
.1
R
.1
R
.1
.1
.1
.1
721.1
718.1
717.1715.1
.1
.1
.1
.1
714A.1
712.1
710.1
714.1 718R.1
717R.1
705.1
.1
.1
.1
712R.1
715R.1
710R.1
719.1
.1
.1
731.1
.2
.1
711.1
142 SF
INFO. TECH.
STAIR 1
STAIR 5
.1
137 SF
NURSE
MANAGER
OFFICE
33 SF
ELEC. CLST
714R.1
28 SF
STORAGE
42 SF
NURSE ALCOVE
51 SF
STAFF TOILET
147 SF
NURSE STATION
CORRIDOR
L
L
.1
A
A
R
.1
AS-408
AS-408
13 AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
AS-408
SIM.
EYE WASH
E Y
E W
A S
H
.1
.1
7 SF
STORAGE
52 SF
EXISTING
WOMEN'S
RESTROOM
AREA OF WORK
OUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
EXISTING WALLS
NEW WALLS
AREA OF NO WORK
FLOOR PLAN LEGEND
.1
DOOR AND DOOR NUMBER
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONARCHITECTURAL FLOOR PLAN
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
AS-101
100% BID DOCUMENTS
635-16-101
N
1/8" = 1'-0"
FLOOR PLAN - ARCHITECTURAL
UP 106 SF
ANTE ROOM
714A
261 SF
PATIENT ROOM
(ISO)
273 SF
PATIENT ROOM
62 SF
PATIENT
TOILET
717R
284 SF
PATIENT ROOM
56 SF
PATIENT
TOILET
718R
83 SF
PATIENT
TOILET
714R
39 SF
CLEAN SUPPLY
264 SF
PATIENT ROOM
59 SF
PATIENT
TOILET
715R
57 SF
PATIENT
TOILET
712R
301 SF
PATIENT ROOM
268 SF
PATIENT ROOM
(BARIATRIC)
71071 SF
PATIENT
TOILET
710R
38 SF
OXYGEN
STORAGE
50 SF
TOILET
217 SF
NOURISHMENT /
WAITING
138 SF
CONSULT
305 SF
STAFF LOUNGE
NURSE WORK
ROOM
175 SF
MED ROOM & IV
STORAGE
128 SF
STORAGE
51 SF
PATIENT
TOILET
724R
51 SF
PATIENT
TOILET
722R
263 SF
PATIENT ROOM
99 SF
CLEAN UTILITY
35 SF
CRASH CART
ALCOVE
261 SF
PATIENT ROOM
51 SF
PATIENT
TOILET
725R
51 SF
PATIENT
TOILET
723R
262 SF
PATIENT ROOM
66 SF
HAC
83 SF
SOILED UTILITY
263 SF
PATIENT ROOM
93 SF
CLEAN LINEN
B
B
C
C
D
D
E
E
F
F
G
G
I
I
J
J
K
K
8 8
6 6
7 7
5 5
4 4
F .V
/2
F .V
F.V.
9' - 7" 11' - 6"
/2
F .V
/2
1' - 4" F.V.
7' - 0" 11 1/2"
1' - 4" 6' - 9 1/2" 11' - 4 1/2" 9' - 8" 10' - 10" 8' - 8"
F.V.
18' - 10 1/2"
8' - 0"
F.V.
18' - 2 1/2"
F .V
F .V
F.V.
13' - 9"
F.V.
13' - 8"
6' - 6" 6' - 5 1/2" 10 1/2" 6' - 4 1/2"
8' - 9" 1' - 9 1/2"
/2
F .V
F .V
CLEAR
8' - 0" MIN.
7' - 11"
142 SF
INFO. TECH.
8A
8B
4A
4A
8A
4C
8A
4C
4C
3A
4A
4A
6A
6A
3A
STAIR 1
STAIR 5
6A6A6A
3A
6A
137 SF
NURSE
MANAGER
OFFICE
4A
4A
6A
L
L
147 SF
NURSE STATION
51 SF
STAFF TOILET
4C
4C
8A
6A
9A
9A
4A 6A
.1
.1
R
.1
.1
R
.1
R
.1
.1
.1
721.1
720.1
719.1
711.1
712.1
712R.1
715R.1
715.1
717R.1
717.1
718.1
718R.1
714R.1
714.1
714A.1 7
.1
.1
710.1
710R.1
.1
.1
.1
705.1
731.1
.1
.1
.1
.1
.1
.2
8A
9A
8B
4A 1A9A
6A6A
9A
9A
9A
6A
6A
4C
4C
8B
9A
9A
6A
6A
4A
4C
3A
4A
8B
4C
8A
6A6A6A6A
10A
8B 4A
8A
8A8B8A
9A
9A
1A
6A6A
4A6A
4C
4C 4C
4A
2A
2A
1A
4C
4C
4C
1A
6A
4C
4A
9A
3C
1B
9A 9A
1A
1A
1B
4C 6A
1A
4A
1B
3E3E
4C
4A
9A
9A8B 6A
4C
1B
R
.1
1A 1A 1A 6A
1A
8A
8A
10A
10A
4A3A
6' - 5 1/2"
2A
F .V
/2
" 7
F .V
/2
F .V
/2
9' - 1"
9' - 3"
F.V.
1' - 5 1/2"
17' - 9" 9' - 4" 22' - 1 1/2" 7' - 1" 10' - 2"
8' - 2"
F.V.
12' - 8 1/2"
ALIGN NEW W/ EXIST.
ADJ. WALL TYP.
10' - 2" 5' - 11"
3E
3E
.1 3E
/2
7B 7B
6A
6A6A
6A
6A
7C 7C
7D
7B
7B
7B
7B
1B 1A
1B
1D 1A
F .V
/2
3E 3E 3E
3E
A
A
1A
1B1B
1B
1C 1C
4C 4C
6A
6A6A10A
28 SF
STORAGE
1A 1B
4A
3E3C 3C
4A
9A
1B
7C
4C
4A
6A
1B 6A
1B
1A
1A
3A
8A
6A
1B
1B 4C
6A6A
4A
4A
2A
1B
6A6A
1B1A
4A
4A3C
1A 1B1B
.0
42 SF
NURSE ALCOVE
33 SF
ELEC. CLST
156 SF
CORRIDOR
979 SF
CORRIDOR
611 SF
CORRIDOR
1A
1A
3C
6A
6A6A
6A
6A6A
7' - 8"
4C
4C4C
7 SF
STORAGE
6A
6A
2' - 8 1/2" 5' - 5"
/2
/2 "1
/2
1B
4C
6A
4C
6A
/2
1' - 8 1/2"
10A6A
2' - 1" 11"
/2
6A
6A
.1
6A
5B
5B
5B
5B
.1
10 1/2"
/2
REF: AS-408 FOR WARDROBE
DIMENSIONS TYP.
7B
F .V
3E3E
3E
4A
6A
REF: 8/AS-404
C L E
A R
M
IN
52 SF
EXISTING
WOMEN'S
RESTROOM
AREA OF WORK
OUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
GENERAL FLOOR PLAN NOTES
1. ALL DOOR FRAMES TO BE LOCATED 2" FROM
OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. REFER TO DOOR SCHEDULE & DETAILS SHEET
FOR DOOR INFORMATION.
3. REFER TO GLAZING ELEVATIONS & DETAILS
SHEET FOR WINDOW INFORMATION.
4. ALL NEW WALLS ARE DIMENSIONED TO
CENTERLINE OF METAL STUD, UNLESS NOTED
OTHERWISE.
5. ALL EXISTING WALLS DIMENSION TO FINISH
FACE, UNLESS NOTED OTHERWISE.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS
NEEDED UNLESS NOTED OTHERWISE.
7. ALL WALLS ARE TYPE 1A PARTITIONS UNLESS
OTHERWISE NOTED. REFER TO PARTITION
TYPE SHEET FOR WALL TYPES.
EXISTING WALLS
NEW WALLS
AREA OF NO WORK
DIMENSION PLAN LEGEND
WALL TAG; REFERENCE SHEET GI-100
FOR WALL TYPES
.1
DOOR AND DOOR NUMBER
1A
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONDIMENSION FLOOR PLAN
02/05/2019 JEH ZDL
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
AS-102
100% BID DOCUMENTS
635-16-101
N
1/8" = 1'-0"
FLOOR PLAN - DIMENSION PLAN
EXIT LIGHT
2' x 2' ACT CEILING
GYP. BD. CEILING
2 x 2 LIGHT FIXTURE
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
CEILING HEIGHT, A.F.F.
8" DIAMETER RECESSED CAN LIGHT
PATIENT LIFT TRACK
REF. MEDICAL EQUIPMENT
SUSPENDED LIGHT FIXTURE
REF. ELECTRICAL
RCP LEGEND
8'-0"
CURTAIN TRACK
2 x 4 LIGHT FIXTURE
OVERBED LIGHT, 6'-6" A.F.F.
VARIES, REF. RCP
CEILING TILE AND
GRID AS SCHEDULED
CEILING TILE AND
GRID AS SCHEDULED
BRACE TO
STRUCTURE
METAL STUD
FRAMING
EXTEND
GYPSUM
WALLBOARD
6" ABOVE
CEILING TILE
PAINTED GYPSUM WALLBOARD
V A
R
IE
S
V A
R
IE
S
DIMENSION VARIES,
REFERENCE RCP
DIMENSION VARIES,
REFERENCE RCP
CEILING TILE AND
GRID AS
SCHEDULED
METAL STUD FRAMING
EXTEND GYPSUM WALLBOARD 6"
ABOVE CEILING TILE
PAINTED GYPSUM WALLBOARD
BRACING AS
REQUIRED
V A
R
IE
S
GENERAL RCP NOTES
1. ALL CEILINGS 8'-0" UNLESS NOTED OTHERWISE
2. PATIENT LIFTS TO HAVE 1,100 BARIATRIC CAPACITY.
3. PROVIDE CEILING CLIPS IN ISOLATION ROOM AND ANTE
ROOM.
4. REFER TO FIRE PROTECTION PLAN FOR SPRINKLER
HEAD LOCATIONS IN WORK AREA.
ANTE ROOM
714A
PATIENT
ROOM
(ISO)
PATIENT
ROOM
PATIENT
TOILET
717R
PATIENT
ROOM
PATIENT
TOILET
718R
PATIENT
TOILET
714R
CLEAN
SUPPLY
PATIENT
ROOM
PATIENT
TOILET
715R
PATIENT
TOILET
712R
PATIENT
ROOM
PATIENT ROOM
(BARIATRIC)
PATIENT
TOILET
710R
OXYGEN
STORAGE
TOILET
NOURISHMENT /
WAITING
CONSULT
STAFF LOUNGE
NURSE WORK
ROOM
MED ROOM & IV
STORAGE
STORAGE
PATIENT
TOILET
724R
PATIENT
TOILET
722R
PATIENT
ROOM
CLEAN
UTILITY
CRASH CART
ALCOVE
PATIENT
ROOM
PATIENT
TOILET
725R
PATIENT
TOILET
723R
PATIENT
ROOM
HAC
SOILED UTILITY
PATIENT
ROOM
B
B
C
C
D
D
E
E
F
F
G
G
I
I
J
J
K
K
8 8
6 6
7 7
5 5
4 4
AS-400
AS-400
AS-401
AS-401
AS-403
AS-402
AS-402
AS-402
AS-403
AS-403
CLEAN
LINEN
AS-103
AS-103
AS-103
INFO. TECH.
STAFF
TOILET
7' - 10"
7' - 10"
L
L
NURSE
STATION
NURSE MANAGER
OFFICE
A
A
OPEN TO STRUCTURE
7' - 10"
7' - 10"
7' - 10"
3' - 4" 3' - 4"
E Q
E Q
AS-404
AS-404
7' - 10"
1' - 0" CORRIDOR
CORRIDOR
REPLACE AND REPAIR ANY
DAMAGED TILES OR LIGHTS
DUE TO CONSTRUCTION. TIE
BACK IN TO EXISTING GRID
AS REQUIRED.
ALIGN GRID WITH EXISTING
52 SF
EXISTING
WOMEN'S
RESTROOM
AREA OF WORK
OUT OF SCOPE
NORTH
F
C B
G
19D185
AREA OF WORK
ADJACENT CEILING TO REMAIN1
RCP KEYNOTES
PAINT CEILING TO MATCH EXISTING2
CEILING AS SCHEDULED
TRAVERSE RAIL
FIXED RECESSED RAIL
NOTE: COORDINATE PATIENT LIFT
RAILS WITH ALL CEILING MOUNTED
FIXTURES AND SPRINKLER SYSTEM
DRAWING
VA PROJECT
DATE
PROJECT TITLE
BUILDING PROJECT
CHECKED BY DRAWN BY
APPROVED: CHIEF ENGINEER
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM
Office of Construction and Facilities Management
Dwg
CONSULTANTS
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR
APPROVED: CHIEF
F U
L L
Y S
P R
IN
K
L E
R E
D
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
SHEET TITLE
ARCHITECT / ENGINEER 7 EAST RENOVATIONREFLECTED CEILING PLAN
02/05/2019 JEH JET
921 N.E. 13TH STREET
OKLAHOMA CITY, OKLAHOMA 73104
AS-103
100% BID DOCUMENTS
635-16-101
1 1/2" = 1'-0"
CEILING DETAIL - TYPICAL CORRIDOR BULKHEAD
1 1/2" = 1'-0"
CEILING DETAIL - TYPICAL FURRDOWN
N
1/8" = 1'-0"
REFLECTED CEILING PLAN
1 1/2" = 1'-0"
CEILING DETAIL - TYPICAL PATIENT LIFT TRACK
UPUP
CLEAN
UTILITY
CLEAN
LINEN
HAC
ANTE ROOM
714A
PATIENT
ROOM
(ISO)
PATIENT
TOILET
714R
CLEAN SUPPLY
PATIENT
ROOM
PATIENT
ROOM
PATIENT ROOM
(BARIATRIC)
PATIENT
TOILET
710R
OXYGEN
STORAGE
TOILET
NOURISHMENT /
WAITING
CONSULT
STAFF LOUNGE
NURSE WORK
ROOM
MED ROOM & IV
STORAGE
PATIENT
TOILET
724R
PATIENT
TOILET
722R
PATIENT
ROOM
CRASH
CART
ALCOVE
PATIENT
ROOM
PATIENT
TOILET
725R
PATIENT
TOILET
723R
PATIENT
ROOM
SOILED UTILITY
PATIENT
ROOM
INFO. TECH.
NURSE
STATION
NURSE
MANAGER
OFFICE
STAFF TOILET
BID OPTION 1
(1,192 SF)
F.V.
38' - 4 1/2"
.1
710.1
710R.1
.1
.1
.1
705.1
.1
.1
.1
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.