ASI_01_COMPLETE_REV_01 003.pdf

PDF 44 MB Posted

Attached to
Y1DA--Reconfigure Outpatient Rehab Medicine 674-21-101
Solicitation number
36C25725R0052
Issued by

View the file

Other files

File Type Posted
36C25725R0052 0005.docx DOCX document
36C25725R0052 0003.docx DOCX document
36C25725R0052 0001.docx DOCX document
Qlean Air Drawings.pdf PDF
ATTACHEMNT K - CONTROLS SPEC.pdf PDF
36C25725R0052 0004.docx DOCX document
Contractor Site Visit Sign-In Sheet - Reconfigure Outpatient Rehab Medicine - 08.06.2025.pdf PDF
Consolidated Request for Information with responses.pdf PDF
18708 Final Report Bldg 163.pdf PDF
36C25725R0052_2-Solicitation-Revision 1 8-7-25.docx DOCX document
36C25725R0052 0002.docx DOCX document
S02 36C25725R0052_2-Solicitation-Revision 1 8-7-25.docx DOCX document
S06 36C25725R0052 0002.docx DOCX document
S06 36C25725R0052 0001.docx DOCX document
S04 Contractor Site Visit Sign-In Sheet - Reconfigure Outpatient Rehab Medicine - 08.06.2025.pdf PDF
Attachment 8 Price Breakout.xlsx XLSX spreadsheet
Attachment 6 ASI 02 REV 02 REMOVE ALTERNATES.pdf PDF
Attachment 5 Specifications Volume 3-MEQ.pdf PDF
Attachment 2 Drawings.pdf PDF
Attachment 7 Wage Determination-Bell County.pdf PDF
Attachment 1 SOW Reconfigure Outpatient Rehab Medicine.pdf PDF
36C25725R0052_2.docx DOCX document
Attachment 4 Specifications Volume 2-MEP.pdf PDF
Attachment 3 Specifications Volume 1-Architecture.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARCHITECT’S SUPPLEMENTAL INSTRUCTIONS

PROJECT: ASI NO: 01

Reconfigure Outpatient Rehab Medicine DATE OF ISSUE: 10/17/2022

VA Project #674-21-101

OWNER: ARCHITECT:

Olin E. Teague Veterans Center Enapay, LLC

1901 Veterans Memorial Drive 207 West Main Street

Temple, TX 76504 Mesquite, TX 75149

The Work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract documents.

Description:

Refer to attached Revision 01 drawings and specifications dated 10/17/2022 that contain Owner changes and corrections. Revision 01 drawings include the following sheets: A-000, A-001, A-002, A-100, A-101, A-102, A-103, A-104, A-105, A-106, A-107, A-108, A-109, A-110, A-111, A-112, A-113, A-114, A-115, A-116, A-117, A-119, A-120, A-121, A-204, A-205, A-400, A-503, A-600, A-600A, A-601, A-602, A-605, A-701, A-872, S-001, S-101, S-106, S-108, S-200, QH-114, QH-116, QH-400, QH-401, FA-107, FA-108, FA-109, FP-106, FP-107, FP-108, FP-109, TN-001, TN-109, TN-400, M-001, M-701, M-702, M-801, M-802, M-803, MH-114, MH-115, MH-116, MH-117, MH-118, MH-119, MH-120, MI-901, MI-902, E-001, E-002, E-400, E-401, EL-100, EP-100, EP-101, EP-102, EP-103, P-001, P-700, PD-106, PD-110, PD-111, PD-113, PL-114, PL-115, PL-116, PL-117, PL-118, PL-119, PL-120, PL-121, Specifications Vol. 1 Table of Contents revised, added section 099659 Key Resin Wall

Coating, added section 105113 Metal Lockers, and the SSR Engineers MEQ Reports Guide.

Requested by: 10/17/2022

Mark D. McComas, PM

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE

T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

PROJECT NUMBER:

ISSUE DATE:

EA #:

CLIENT #:

PROJECT DIRECTORY:

EA04.0101

REV 01 / 10-17-2022

OLIN E. TEAGUE VETERANS' CENTER

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS 76504 ISSUED FOR CONSTRUCTION - REV 01

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

E A

.0

REV 01 / 10-17-2022

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

RECONFIGURE OUTPATIENT REHAB MEDICINE

A-000

674-21-101

S N E

HP

ET

SNNYL

R E

G O

R

E T

RA

C

H

I

E

S

T

I

E R

D

T

S

T E X

A6

S

O F

3 3A T

E

T

C

E R

G

CAMPUS MAP - PROJECT LOCATION

PROJECT WORK - BASEMENT , VERTICAL

CHASES THROUGH FIRST AND SECOND

LEVELS TO THE ROOF

THE GENERAL CONTRACTOR IS TO COORDINATE WITH

THE VA's COR ITS STAGING AREA

CALLOUT HEAD

DOOR TAG

? INTERIOR ELEVATION

ROOM TAG WITH

AREA

BUILDING SECTION

SPOT ELEVATION - TARGET

? WALL TAG

? WINDOW TAG

TEMP. CONSTRUCTION PARTITION

REVISION SYMBOL

REVISION NUMBER

CABINET / CEILING SECTION

EQUIPMENT TAG EQ.000

ROOM SIGNAGE TAG

X

A1/A001

KEYNOTE LEGEND

KEY VALUE KEYNOTE TEXT

09 29 00.A1 DESCRIPTIONSPECIFICATION SECTION KEYNOTE INFORMATION

ABBREVIATIONS AND ANNOTATIONS LEGEND

ROOM NAME

ROOM SF

01 PHOTO CALLOUT

N.I.C. NOT IN CONTRACT

FIRE EXTINGUISHER - WALL MOUNTEDFE

FIRE EXTINGUISHER - CABINETFE

ADDITIONAL NOTES

PROJECT SCOPE

PROJECT SCOPE:

THE PROJECT INVOLVES THE DEMOLITION OF

APPROXIMATELY 26,000 GSF WHICH INCLUDES AN EXISTING

PHARMACY SERVICE / STERILIZATION / WORK AREA, MEN'S

AND WOMEN'S TOILETS AND LOCKER ROOMS, EXAM ROOMS,

TREATMENT ROOMS, OCCUPATIONAL THERAPY, THERAPEUTIC

POOL, PM&RS STORAGE, KINESIOTHERAPY AND WAITING /

RECEPTION.

NEW CONSTRUCTION WILL INCLUDE A NEW PHARMACY FLOOR

/ PHARMACY ROBOT AREA / IV AND STERILIZATION ROOMS /

WORK ROOM, VAULT, CONFERENCE ROOMS, OFFICES,

RECEPTION / WAITING AREA, MEN'S AND WOMEN'S LOCKER

ROOMS AND TOILET ROOMS, PT/KT MOBILITY GYM,

TELEHEALTH AREAS AND EXAM ROOMS, ALL TO BE LOCATED

IN THE BASEMENT OF BUILDING 163.

THE PROJECT IS TO BE CONSTRUCTED IN FOUR PHASES. THE

PHASES WILL BE COMPLETED SUCCESSIVELY AND ACCEPTED

BY THE VA BEFORE THE NEXT PHASE CAN BEGIN.

THE GC IS TO COORDINATE ITS STAGING AREA(S).

PROJECT DATA AND BUILDING

CODE INFORMATION

PROJECT DATA

PROJECT NAME:

PROJECT ADDRESS:

OWNER:

APPLICABLE CODES

BUILDING CODE:

ACCESSIBILITY CODE: 2010 STANDARDS FOR ACCESSIBLE

DESIGN (SAD)

2021 INTERNATIONAL BUILDING CODE

TABS PROJECT NUMBER: NA

RECONFIGURE OUTPATIENT REHAB

MEDICINE

MECHANICAL CODE:

ELECTRICAL

CODE:

PLUMBING CODE:

NFPA: 2015 NFPA 101 LIFE SAFETY CODE \

NFPA 12A (2009), 92 (2012), 204 (2012)

2021 INTERNATIONAL MECHANICAL

CODE

2021NATIONAL ELECTRICAL CODE

(NFPA 70)

2021 INTERNATIONAL PLUMBING CODE

OSBC: NFPA 10, 20 (2010),70, 30, 45 (2011), 99

(2012), 13, 72 (2013)

FUEL AND GAS: 2015 INTERNATIONAL FUEL AND GAS

CODE

ENERGY CODE: 2015 INTERNATIONAL ENERGY

CONVERSATION CODE / 2013 ASHRAE

90.1.

LIFE SAFETY INFORMATION

OCCUPANCY: BUSINESS

COMMENTS

TYPE OF

CONSTRUCTION:

EXISTING NA

SPRINKLER SYSTEM: EXISTING NA

COMMENTSFIRE PROTECTION REQUIREMENTS

INT. BEARING WALLS: EXISTING

EXT.BEARING WALLS: EXISTING

EXISTING

EXISTING

INT. NONBEARING WALLS:

EXT. NONBEARING WALLS:

EXISTING

EXISTING

EXISTING

ROOF:

CEILING:

FLOOR

STRUCTURAL BEAMS:

STRUCTURAL COLUMNS:

EXISTING

EXISTING

RATED SEPARATIONS: EXISTING

MEANS OF EGRESS

TOTAL OCCUPANT LOAD:

MAX. ALLOWED MAX. PROVIDED

X / 100

REF. TO LIFE SAFETY PLAN

DIST. BETWEEN EXITS: 112'-0" EXISTING

X/2 IF SPRINKLED

EGRESS WIDTH / OCCUPANT MIN. ALLOWED PROVIDED

0.2" STAIRS:

0.15" DOORS:

EXISTING

EXISTING EXISTING

EXISTING

EXISTINGEXISTING

NA

ACOUSTICAL DESIGN: ASHRAE APPLICATIONS VOLUME,

CHAPTER 42 / ANSI S1.8 / ASA 84

COMMENTS

COMMENTS

COMMENTS

COMMENTS

COMMENTS

TRAVEL DISTANCE TO EXIT: 200'-0" EXISTING

OLIN E. TEAGUE VETERANS CENTER

1901 VETERANS MEMORIAL DRIVE

TEMPLE. TEXAS 76504

DEPARTMENT OF VETERANS AFFAIRS

GRAPHIC REPRESENTATION: THE CONSTRUCTION DRAWINGS ARE

A GRAPHIC REPRESENTATION OF THE SCOPE, LOCATION, AND

ARRANGEMENT OF MATERIALS AND EQUIPMENT SHOWING THE

EXECUTION OF THE WORK. THE INTENT OF THE SPECIFICATIONS IS

TO OUTLINE AND/OR FURTHER INDICATE THE TYPES AND QUALITIES

OF THE MATERIALS AND WORKMANSHIP. SHOULD THE

SPECIFICATIONS AND CONSTRUCTIONS DRAWINGS DISAGREE IN

THEMSELVES OR WITH EACH OTHER, WRITTEN CLARIFICATIONS IN

THE FORM OF A REQUEST FOR INFORMATION (RFI) SHALL BE

ISSUED TO THE ARCHITECT BY THE GENERAL CONTRACTOR. IN

ABSENSE OF THE RFI, THE GENERAL CONTRACTOR'S PROPOSAL

SHALL BE BASED UPON THE MOST EXPENSIVE COMBINATION OF

QUALITY AND QUANTITY OF WORK INDICATED.

CONFLICTS: IN CASES OF CONFLICTS, INCONSISTENCIES OR

DISCREPANCIES WITHIN THE CONSTRUCTION DRAWINGS AND

SPECIFICATIONS, THE GENERAL CONTRACTOR SHALL PROVIDE

THE BETTER QUALITY AND GREATER QUANTITY OF WORK AS

DETERMINED AND DIRECTED BY THE OWNER.

1.

2.

GENERAL PROJECT NOTES

3.

4.

5.

6.

8.

7.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

28.

27.

26.

25.

24.

23.

22.

21.

20.

19.

ERRORS / OMISSIONS IN THE SCHEDULES: SUCH AS THE ROOM

FINISH SCHEDULE, DOOR SCHEDULE AND EQUIPMENT SCHEDULE

SHALL NOT RELIEVE THE GENERAL CONTRACTOR FROM THE

PERFORMANCE OF THE WORK AS SHOWN IN THE CONSTRUCTION

DRAWINGS OR SPECIFICATIONS.

ASBESTOS: IF DURING DEMOLITION ASBESTOS IS FOUND WORK

SHALL NOT PROCEED UNTIL A COMPLETE ASBESTOS SURVEY OF

THE PROJECT AREA HAS BEEN CONDUCTED AND A DETAILED

ABATEMENT REPORT ISSUED TO THE OWNER.

EQUIPMENT VERIFICATION: THE GENERAL CONTRACTOR SHALL

BE RESPONSIBLE FOR THE VERIFICATION OF THE SIZE AND

LOCATION OF ALL OPENINGS FOR THE MECHANICAL / ELECTRICAL /

PLUMBING WORK AND EQUIPMENT AND SHALL COORDINATE WITH

ALL SUB-CONTRACTORS INVOLVED.

SIGNAGE: THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE

REMOVAL OF ALL ROOM SIGNAGE WITHIN THE PROJECT AREA.

REQUIRED UTILITIES: THE GENERAL CONTRACTOR SHALL REFER

TO THE FLOOR PLANS, FURNITURE PLANS, EQUIPMENT PLANS

AND INTERIOR ELEVATIONS FOR ALL ITEMS TO BE WALL

MOUNTED, BUILT-IN TO PARTITIONS, OR SUSPENDED FROM THE

STRUCTURE AND SHALL PROVIDE THE REQUIRED UTILITIES AND

SHALL PROVIDE LIMITED ASSISTANCE IN THE CONNECTION TO

FURNITURE SYSTEMS, FIXTURES AND EQUIPMENT.

SERVICE TO UTILITIES: THE GENERAL CONTRACTOR SHALL

MAINTAIN SERVICE TO EQUIPMENT UTILITIES AND PROTECT

AGAINST DAMAGE TO SUCH DURING CONSTRUCTION AND SHALL

NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED /

OPERATING FACILITIES EXCEPT WHEN AUTHORIZED IN WRITING

BY THE OWNER AND AUTHORITIES HAVING JURISDICTION. REFER

TO THE SPECIFICATIONS FOR PROTOCOLS DEALING WITH

FACILITY SHUT DOWNS.

BYPASS CONNECTIONS: WHERE UTILITY SERVICES ARE

REQUIRED TO BE REMOVED, RELOCATED OR MODIFIED,

PROVIDE BYPASS CONNECTIONS TO MAINTAIN CONTINUITY OF

SERVICE BEFORE PROCEEDING WITH THE WORK.

COORDINATE WITH THE OWNER.

NOT ALLOWED: NO GASOLINE POWERED TOOLS OR POWER

ACTUATED FASTENING DEVICES SHALL BE ALLOWED INSIDE THE

FACILITY.

EGRESS: THE GENERAL CONTRACTOR SHALL MAINTAIN

EXISTING EXITS SERVING THE PROJECT AREA THROUGHOUT

CONSTRUCTION.

STANDARD REFERENCED DESIGN SHEETS: THE FOLLOWING

SHEETS CONTAIN STANDARD ARCHITECTURAL DESIGN

INFORMATION: A-872 ACCESSIBILITY FIXTURE MOUNTING

HEIGHTS.

WINDOW AND DOOR OPENINGS: WILL BE SCHEDULED AS FOLLOWS:

WINDOW OPENINGS WILL BE DESIGNATED BY A LETTER SUCH AS 'A'.

DOOR OPENINGS WILL CONTAIN THE ROOM NUMBER FOLLOWED BY

A DOT AND NUMBER. EXAMPLE: ROOM NUMBER 1001 WITH DOOR

OPENING NUMBER 1001.1.

ABBREVIATIONS: REFERENCED FROM THE U.S. NATIONAL

CAD STANDARD VERSION 6.0.

BLOCKING: THE GENERAL CONTRACTOR IS RESPONSIBLE FOR

PROVIDING FIRE TREATED WOOD BLOCKING IN THE WALLS FOR

ALL WALL MOUNTED FIXTURES AND EQUIPMENT.

CONSTRUCTION: CONSTRUCTION SHALL COMPLY WITH THE

APPLICABLE REQUIREMENTS OF NFPA 101 AND THE

REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. IF

THERE IS NO APPLICABLE LOCAL CODE(S), THE MOST

CURRENT RECOGNIZED MODEL BUILDING CODES SHALL BE

APPLIED.

DESIGN STANDARDS: EACH BUILDING OR PORTION

THEREOF SHALL BE DESIGNED AND CONSTRUCTED TO

SUSTAIN ALL LIVE AND DEAD LOADS, INCLUDING

SEISMIC AND OTHER ENVIRONMENTAL FORCES IN

ACCORDANCE WITH ACCEPTED ENGINEERING

PRACTICES AND STANDARDS AS PRESCRIBED BY THE

LOCAL JURISDICTION OR BY THE MOST CURRENT

MODEL BUILDING CODES.

DIMENSIONS: ARE TYPICALLY SHOWN FROM A COLUMN

CENTER LINE TO THE FINISH FACE OF A WALL OR FROM THE

FINISH FACE OF A WALL TO THE FINISH FACE OF WALL.

DO NOT SCALE THE DRAWINGS: USE FIGURED DIMENSIONS ONLY.

ENLARGED PLANS: WHERE ENLARGED OR PARTIAL PLANS ARE

REFERENCED, DIMENSIONS AND SPECIAL DETAILING OR FINISH

REQUIREMENTS ARE NOTED ON THE ENLARGED PLANS AND

ARE USUALLY OMITTED FROM THE SMALLER SCALE PLANS.

EXISTING CONDITIONS: ONLY THE AREAS DESCRIBED IN

F7/A-001 PROJECT SCOPE HAVE BEEN FIELD-VERIFIED. THIS

MEANS THAT THE EXISTING PARTITION WALLS HAVE BEEN

PARTIALLY LOCATED, MOST OF THE VISIBLE MECHANICAL,

ELECTRICAL AND PLUMBING ITEMS HAVE BEEN LOCATED, AND

MOST OF THE VISIBLE ARCHITECTURAL ELEMENTS LOCATED.

AREAS THAT ARE CONCEALED OR NOT ACCESSIBLE HAVE NOT

BEEN FIELD VERIFIED.

FIELD VERIFY: THE GENERAL CONTRACTOR IS TO FIELD VERIFY

ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH

THE SCHEDULED WORK AS WELL AS COORDINATING THE

EXISTING CONDITIONS WITH THE SCHEDULED WORK. WHEN THE

GENERAL CONTRACTOR IDENTIFIES A POTENTIAL LOCATION

PROBLEM WITH HVAC, PLUMBING, ELECTRICAL, OR SPRINKLER

SYSTEMS HE IS TO NOTIFY THE DESIGN PROFESSIONAL IN

WRITING BEFORE PROCEEDING WITH THE SCHEDULED WORK.

FIRE ALARM: ALL HEALTHCARE OCCUPANCIES SHALL BE PROVIDED

WITH A FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72 AND

NFPA 101.

INTERIOR FINISHES: INTERIOR FINISH MATERIALS SHALL COMPLY

WITH THE FLAME SPREAD AND SMOKE PRODUCTION

LIMITATIONS AS INDICATED IN NFPA 101.

LIFE SAFETY SYSTEMS: ALL SYSTEMS ARE TO REMAIN FULLY

OPERATIONAL OVER THE COURSE OF THE CONSTRUCTION

PROJECT. ALL FIRE SPRINKLERS IN LOCATIONS WITH THE CEILING

BEING REMOVED ARE TO BE TURNED UP DURING CONSTRUCTION.

ALL FIRE SPRINKLERS ARE TO BE RETURNED TO NORMAL

FUNCTION AND ORIENTATION ONCE CONSTRUCTION IS COMPLETE.

EXISTING FIRE ALARM DEVICES: INCLUDING BUT NOT LIMITED TO,

SMOKE AND HEAT DETECTORS, MANUAL PULL STATIONS,

SPEAKERS, AND STROBES ARE TO BE SECURED OR REMOVED

PRIOR TO DEMOLITION OF A WALL OR CEILING CONTAINING A FIRE

ALARM DEVICE. IF THE DEVICES ARE LEFT IN PLACE DURING

DEMOLITION, THEY SHALL BE SECURED TO PROTECT AGAINST

PHYSICAL DAMAGE AND/OR CONTAMINATION. IN ADDITION,

DEVICES LEFT IN PLACE SHALL NEVER BE SUPPORTED BY THEIR

CONDUCTORS AT ANY TIME. IF THE DEVICES ARE TO BE REMOVED,

THEY SHALL BE REMOVED BY A STATE LICENSED FIRE ALARM

TECHNICIAN.

DESIGN AND INSTALLATION OF FIRE PROTECTION AND LIFE

SAFETY EQUIPMENT: ALL WORK SHALL BE PERFORMED BY A

LICENSED FIRE PROTECTION ENGINEER OR A TEXAS STATE FIRE

MARSHALL'S OFFICE LICENSED CONTRACTOR AS FOLLOWS:

FIRE ALARM DESIGN - "FIRE ALARM PLANNING SUPERINTENDENT"

(APS) LICENSE / FIRE ALARM INSTALLATION AND SERVICE - "FIRE

ALARM TECHNICIAN" (FAL) LICENSE / FIRE SPRINKLER SYSTEM

DESIGN - "RESPONSIBLE MANAGING EMPLOYEE (RME) LICENSE.

FIRE PROTECTION AND LIFE SAFETY EQUIPMENT: INCLUDING FIRE

ALARM DEVICES, FIRE SPRINKLERS, FIRE EXTINGUISHERS,

EMERGENCY LIGHTING, AND EXIST SIGNS SHALL BE INSTALLED IN

ACCORDANCE WITH THE REQUIREMENTS OF THE FOLLOWING:

NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS / NFPA

13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS /

NFPA 72 NATIONAL FIRE ALARM CODE / NFPA 101 LIFE SAFETY

CODE.

29. DUST PARTITION: WHERE A DUST PARTITION IS REFERENCED ON

THE DEMOLITION OR NEW FLOOR PLAN IT SHALL BE CONSTRUCTED

AS A SMOKE BARRIER WITH A 1 HOUR RATING. THIS SHALL BE

MAINTAINED OR MODIFIED THROUGHOUT ALL PHASES OF

CONSTRUCTION UNTIL PROJECT COMPLETION.

30. TOILET ACCESSORY LEGEND: REFER TO F8/A-872.

GC RESPONSIBILITIES TO

EXISTING CONDITIONS

1.

2.

3.

4.

5.

6.

8.

7.

9.

10.

11.

12.

THE CONTRACTOR SHALL PERFORM A SITE VISIT(S). IN DOING

SO THE CONTRACTOR HAS AGREED THAT THEY HAVE

INVESTIGATED THE EXISTING CONDITIONS TO BE RENOVATED

AND COMPARE THEM TO THE WORK TO BE PERFORMED

ACCORDING TO THE CONTRACT DOCUMENTS.

INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD

TO EXISTING CONDITIONS OF CONSTRUCTION IS PROVIDED FOR

THE CONVENIENCE OF THE CONTRACTOR IN EXECUTING THE

NEW WORK. REASONABLE ATTEMPTS HAVE BEEN MADE TO

PROVIDE COMPLETE AND ACCURATE REPRESENTATION OF

SUCH EXISTING CONDITIONS. THIS INTERPRETATION HAS BEEN

DERIVED FROM DRAWINGS SUPPLIED BY THE OWNER AND HAS

BEEN FURTHER SUPPLEMENTED WITH FIELD-MEASUREMENTS

AND PHOTOGRAPHS. THE INFORMATION CONTAINED IN THESE

DRAWINGS WITH REGARD TO THE EXISTING CONDITIONS OF

CONSTRUCTION IN NO WAY RELEASES THE CONTRACTOR FROM

THE RESPONSIBILITY OF VERIFYING COMPLETELY ALL FIELD

CONDITIONS RELATING TO THE EXECUTION OF THE WORK, AS

DESCRIBED IN THE CONTRACT DOCUMENTS.

NO GUARANTEE IS MADE AS TO THE GENERAL CONDITIONS OF

THE EXISTING BUILDING, THE CONTRACTOR SHALL FIELD

VERIFY AND DOCUMENT ALL EXISTING DIMENSIONS,

ELEVATIONS, BENCHMARKS, MATERIALS, UTILITIES AND

CONSTRUCTION TYPE THAT MAY AFFECT OR BE EFFECTED BY

NEW WORK AND SHALL COORDINATE SUCH FIELD

VERIFICATION WITH THE CONTRACT DOCUMENTS AND THE

EXECUTION OF THE WORK. THE CONTRACTOR SHALL NOTE ANY

DISCREPANCIES AND/OR CONFLICTS INVOLVING EXISTING

CONDITIONS AND BRING THEM TO THE ARCHITECT'S ATTENTION

IN WRITING.

THE CONTRACTOR SHALL FIELD-VERIFY THE EXISTING

CONDITIONS AS THEY RELATE TO SPECIFIC PORTIONS OF THE

WORK. VERIFICATION SHALL BE UNDERTAKEN IN ADVANCE TO

ALLOW FOR THE TIMELY IDENTIFICATION OF EXISTING

CONDITIONS THAT MAY AFFECT THE SCHEDULED INSTALLATION

OF NEW WORK AS DESIGNED AND DETAILED, AND TO AVOID

UNIQUE AND UNREASONABLE DELAYS TO THE PROJECT

SHOULD SUCH CONDITIONS BE DISCOVERED. TIMELY

IDENTIFICATION OF SUCH CONDITIONS SHALL PROVIDE FOR A

MINIMUM PERIOD OF TEN (10) WORKING DAYS DURING WHICH

TIME THE ARCHITECT WILL EVALUATE THE CONDITIONS AND

MAKE RECOMMENDATIONS FOR ACCOMMODATING NEW WORK.

THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND

EXTENT OF THE LIFE SAFETY SYSTEM (INCLUDING BUT NOT

LIMITED TO SPRINKLER SYSTEMS, SMOKE DETECTION

SYSTEMS, EMERGENCY LIGHTING SYSTEMS) AS THEY MAY BE

AFFECTED BY THE NEW WORK. THE CONTRACTOR IS

RESPONSIBLE FOR ACCOMMODATING THESE SYSTEMS WHEN

AFFECTED BY NEW WORK SO THAT ALL APPLICABLE CODES

REQUIREMENTS ARE SATISFIED.

THE AREAS ADJACENT TO THE PROJECT ARE CURRENTLY

OCCUPIED, AND MUST REMAIN COMPLETELY OPERATIONAL

DURING THEIR BUSINESS HOURS. THE CONTRACTOR SHALL

COORDINATE WITH THE OWNER ANY CONSTRUCTION

ACTIVITIES WHICH MAY IMPEDE THEIR NORMAL OPERATIONS,

INCLUDING ANY ACTIVITY WHICH CREATES EXCESSIVE NOISE,

VIBRATION, DUST AND NOTIFY ANY OCCUPANTS OF THE

BUILDING OF ANY CONSTRUCTION ACTIVITIES WHICH MAY

AFFECT THEIR ABILITY TO OPERATE NORMALLY.

THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS

TO PREVENT DAMAGE TO AREAS ADJACENT TO NEW

CONSTRUCTION OR OCCUPIED AREAS WHERE VARIOUS

SYSTEMS CONNECTIONS OR EXTENSIONS ARE REQUIRED AND

SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY

CONSTRUCTION ACTIVITIES.

THE CONTRACTOR SHALL IDENTIFY POINTS OF ACCESS TO THE

BUILDING AND VERIFY MINIMUM CLEARANCES AVAILABLE FOR

USE IN TRANSPORTING NECESSARY CONSTRUCTION

MACHINERY, EQUIPMENT, MATERIALS, AND COMPONENTS INTO

THE BUILDING. USE OF SUCH POINTS OF ACCESS SHALL BE

APPROVED BY THE OWNER.

THE CONTRACTOR SHALL IDENTIFY EXISTING COMPONENTS

AND ASSEMBLIES WITHIN THE BUILDING THAT ARE

CONSTRUCTED AS FIRE-RATED OR SMOKE ASSEMBLIES; SHALL

NOTE ANY DISCREPANCIES AND/OR CONFLICTS INVOLVING

EXISTING CONDITIONS AND BRING THEM TO THE ARCHITECT'S

ATTENTION IN WRITING.

THE CONTRACTOR SHALL AT ALL TIMES MAINTAIN THE BUILDING

IN A WEATHER TIGHT CONDITION.

THE CONTRACTOR SHALL PROTECT ALL EXISTING AND NEW

UTILITY LINES ON OR ADJACENT TO THE SITE AND NOTIFY ALL

UTILITY COMPANIES PRIOR TO STARTING DEMOLITION OR NEW

CONSTRUCTION.

THE CONTRACT LIMIT OF WORK SHOWN ON DRAWINGS IS

PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR.

ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY THE

CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR

ENSURING PROPER INTERFACE BETWEEN EXISTING AND NEW

WORK.

DEMOLITION GENERAL NOTES

1.

2.

3.

4.

5.

6.

8.

7.

9.

10.

11.

12.

13.

14.

15.

16.

17.

THE "LIMITS OF CONSTRUCTION" LINES SHOWN ON THE

ARCHITECT'S DEMOLITION PLANS APPLY ONLY TO THE LIMITS

OF THE ARCHITECTURAL DEMOLITION. SEE THE OTHER

DISCIPLINES' DRAWINGS FOR THE LIMITS OF DEMOLITION FOR

THEIR DISCIPLINE.

THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM

EXISTING DRAWINGS WHICH WERE PROVIDED TO THE

ARCHITECT/ENGINEER BY THE OWNER AND THEY MAY NOT

REFLECT ACTUAL FIELD CONDITIONS. PRIOR TO PROCEEDING

WITH ANY WORK, THE CONTRACTOR SHALL VERIFY THE

ACCURACY OF THESE DRAWINGS IN COMPARISON TO EXISTING

FIELD CONDITIONS AND THEN IMMEDIATELY NOTIFY THE

ARCHITECT IN WRITING OF ANY INCONSISTENCIES BETWEEN

THESE DRAWINGS AND ACTUAL CONDITIONS.

DEMOLITION IS INTENDED TO PREPARE THE BUILDING TO

RECEIVE THE NEW WORK. THE INFORMATION PROVIDED IN NO

WAY INTENDS TO MEAN THAT DEMOLITION IS LIMITED ONLY TO

THOSE ITEMS SPECIFICALLY IDENTIFIED. THE CONTRACTOR

SHALL REMOVE ALL EXISTING ITEMS OF CONSTRUCTION AND

EQUIPMENT WITHIN THE PROJECT AREA INDICATED ON THE

DEMOLITION PLAN, INCLUDING, BUT NOT LIMITED TO FLOOR

MATERIAL, BASE, WALLS, CEILINGS, DOORS, DOOR FRAMES,

WINDOWS, WINDOW FRAMES, CASEWORK, ATTACHMENTS,

ELECTRICAL, MECHANICAL, PLUMBING FIXTURES AND SYSTEM,

AS REQUIRED TO ALLOW FOR THE EXECUTION OF NEW WORK.

AFTER DEMOLITION WORK IS COMPLETE, REPAIR ALL HOLES

IN EXISTING-TO-REMAIN FLOORS, WALLS, FIRE BARRIERS,

AND ROOFS TO COMPLY WITH ORIGINAL FIRE/SMOKE/SOUND

ASSEMBLIES, FIRE PROTECTION REQUIREMENTS, AND

STRUCTURAL INTEGRITY.

OWNER SHALL REMOVE ALL NON-BUILT-IN EXISTING MEDICAL

EQUIPMENT STORAGE UNITS AND FURNITURE. THE

CONTRACTOR SHALL REMOVE SUPPORTS, TRACKS, BUILT-IN

ITEMS (STORAGE CABINETS, CASEWORK, ETC.), ALONG WITH

THE NORMAL DEMOLITION WORK. THE CONTRACTOR SHALL

REMOVE AND TURN OVER TO OWNER FOR STORAGE ANY

ANCILLARY PIECES SUCH AS (BUT NOT LIMITED TO) MOUNTING

BRACKETS, HARDWARE, MISC. SUPPORT ITEMS, ETC. REQUIRED

FOR THE REINSTALLATION OF EQUIPMENT; CONTRACTOR TO

SEE EQUIPMENT BOOK FOR INFORMATION ON PLACEMENT AND

INSTALLATION OF EXISTING AND NEW EQUIPMENT.

THE CONTRACTOR SHALL REMOVE ALL ITEMS TO BE

DEMOLISHED IN THEIR ENTIRETY INCLUDING ALL

ASSOCIATED PIPING, WIRING, HANGERS, SUPPORTS,

PROJECTIONS, BOLTS, NAILS, ETC. FROM EXISTING

SURFACES, AND PATCH ALL HOLES TO MATCH ADJACENT

SURFACES OR PROVIDE NEW SCHEDULED FINISHES.

THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN

WRITING IF ANY DEMOLITION OR NEW CONSTRUCTION

WORK CANNOT BE PERFORMED DUE TO EXISTING FIELD

CONDITIONS.

THE CONTRACTOR SHALL BRING TO THE ARCHITECT'S

ATTENTION IN WRITING ANY STRUCTURAL INTERFERENCE

THAT WOULD AFFECT THE EXECUTION OF THE NEW WORK.

NO FLOOR OR STRUCTURAL MEMBER SHALL BE CUT

WITHOUT PERMISSION OF STRUCTURAL ENGINEER OF

RECORD. ALL PROPOSED SLEEVE/ CORING SHALL BE

REVIEWED BY THE ARCHITECT BEFORE PROCEEDING.

WHERE NEW FLOORING IS INDICATED, THE CONTRACTOR

SHALL REMOVE ALL EXISTING FLOOR FINISHES AND ADHESIVE

DOWN TO THE CONCRETE SLAB, AND LEAVE FLOOR SMOOTH

FOR NEW FINISH. THE CONTRACTOR SHALL OBSERVE

MANUFACTURERS REQUIREMENTS FOR SUB-FLOOR

PREPARATION. TREATMENT OF EXISTING FLOOR FINISHES

WITHIN AREAS OF DEMOLITION SHALL BE AS FOLLOWS:

A. CARPET: REMOVE ENTIRELY, INCLUDING PADDING.

REMOVE REMAINING GLUE RESIDUE, TACK

STRIPS AND PATCH AS NECESSARY FOR

NEW FLOOR FINISH.

B. VINYL: REMOVE ENTIRELY AFTER MATERIAL HAS

BEEN TESTED FOR ASBESTOS BY THE VA.

REMOVE GLUE OR GROUT RESIDUE.

PATCH AS NECESSARY TO PROVIDE

LEVEL SURFACE.

C. CERAMIC TILE: REMOVE ENTIRELY. PATCH AND REPAIR

FLOORS WITH A LEVELING COMPOUND TO

PRODUCE A SMOOTH, LEVEL SURFACE TO

RECEIVE NEW FINISHES.

THE CONTRACTOR SHALL REMOVE EXISTING FINISHES,

INCLUDING CERAMIC TILE, VINYL WALL COVERING, WALL

PROTECTION, WALL BASE ETC. AT ALL EXISTING WALLS TO

RECEIVE NEW FINISHES, UNLESS NOTED OTHERWISE, AND

LEAVE WALL SURFACE SMOOTH TO RECEIVE NEW FINISHES.

THE CONTRACTOR SHALL REMOVE ALL EXISTING CEILINGS

TO ALLOW FOR PROPER INSTALLATION OF MECHANICAL,

PLUMBING AND ELECTRICAL WORK, AND PATCH AND

REPAIR EXISTING CEILINGS TO MATCH EXISTING.

WHERE NEW CEILINGS ARE INDICATED, THE CONTRACTOR

SHALL REMOVE ALL EXISTING CEILINGS TO ALLOW FOR

PROPER INSTALLATION OF NEW CEILINGS.

THE CONTRACTOR SHALL REFER TO CIVIL, MECHANICAL,

PLUMBING, FIRE PROTECTION, COMMUNICATIONS, SECURITY

SYSTEMS, AND ELECTRICAL DOCUMENTS FOR REQUIRED

DEMOLITION WORK AS WELL AS EXISTING PIPING, CONDUITS,

DUCTWORK, UTILITIES, ETC. TO REMAIN WITHIN AREAS OF

DEMOLITION

THE CONTRACTOR SHALL COORDINATE DEMOLITION WORK

WITH PHASING PLANS TO DETERMINE THE SCOPE OF WORK

TO BE PERFORMED IN EACH PHASE AND TO CAREFULLY

INTEGRATE WITH EXISTING CONSTRUCTION TO REMAIN FOR

EACH PHASE AND UPON COMPLETION OF FINAL PHASE

WITH MINIMAL DISRUPTION OF BUILDING OPERATIONS.

THE CONTRACTOR SHALL REFER TO MECHANICAL,

PLUMBING, FIRE PROTECTION, ELECTRICAL,

COMMUNICATIONS, AND SECURITY DRAWINGS FOR EXTENT

AND LOCATION OF THE CHANNELING OF EXISTING FLOORS.

IF EXISTING PIPING OR CONDUIT OTHER THAN THE DESIRED

CONNECTION IS ENCOUNTERED WHILE CHANNELING, THE

CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING

PRIOR TO CONTINUING WITH ANY WORK.

DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE

WITH ALL CODES AND ORDINANCES AS SET FORTH BY ALL

AUTHORITIES HAVING JURISDICTION.

THE CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES

AND STRUCTURAL ELEMENTS AS NECESSARY DURING

DEMOLITION. THE CONTRACTOR SHALL ENGAGE A

STRUCTURAL ENGINEER TO DETERMINE REQUIREMENTS.

CUTTING AND PATCHING

GENERAL NOTES

THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING-

TO-REMAIN MATERIALS AND FINISHES (CEILING GRID, CEILING

TILE, GYPSUM BOARD, DOORS, WINDOWS, FRAMES, WALL

PROTECTION, PAINT, ETC) WHICH ARE DAMAGED DURING

DEMOLITION OR CONSTRUCTION OR ANY OTHER WORK

PERFORMED UNDER THIS CONTRACT. THE CONTRACTOR SHALL

PATCH, REPAIR, AND ALIGN ALL EXISTING CONSTRUCTION SO AS

TO LEAVE NO EVIDENCE OF PATCHING OR REPAIR AND PREPARE

EXISTING SURFACE TO RECEIVE NEW SCHEDULED FINISHES.

1.

2.

3.

4.

5.

6.

7.

WHERE EXISTING EXTERIOR WALL OR INTERIOR PARTITIONS

ARE DAMAGED IN AREAS OF SELECTIVE DEMOLITION BY THE

REMOVAL OF EXISTING CONSTRUCTION OR ANY OTHER

DEMOLITION ACTION, THE CONTRACTOR SHALL REPAIR

EXISTING WALL SURFACES TO MATCH EXISTING OR PRODUCE A

SMOOTH SURFACE TO RECEIVE NEW FINISHES.

WHERE LEVEL CHANGES, HOLES, DEPRESSIONS, OR FORMED

TRENCHES ARE UNCOVERED IN EXISTING CONCRETE SLAB BY

THE REMOVAL OF EXISTING WALLS / EXISTING FLOORING OR

ANY OTHER DEMOLITION ACTION, THE CONTRACTOR SHALL

PATCH AND REPAIR EXISTING CONCRETE SURFACES WITH A

LATEX OR GYPCETE LEVELING COMPOUND UNLESS SPECIFIED

OTHERWISE TO PRODUCE A SMOOTH LEVEL SURFACE TO

RECEIVE NEW FINISHES.

WHERE PIPES, CONDUITS, DUCTWORK, ETC. ARE TO BE

REMOVED FROM EXISTING RATED WALL / PARTITION TO

REMAIN, THE CONTRACTOR SHALL INFILL THE OPENING

PENETRATION WITH MATERIALS THAT MATCH THE EXISTING

CONSTRUCTION OR AN APPROVED MATERIAL TO MAINTAIN THE

EXISTING FIRE-RATED OR AND SMOKE ASSEMBLY.

WHERE WALL AREAS ARE LEFT EXPOSED AS A RESULT OF AN

ADJUSTMENT IN FINISH CEILING HEIGHT, THE CONTRACTOR

SHALL REPAIR EXISTING WALL SURFACES TO MATCH EXISTING

OR PRODUCES A SMOOTH SURFACE TO RECEIVE NEW FINISHES

WHERE PIPES, CONDUITS, DUCTWORK, ETC. ARE TO BE

REMOVED FROM ANY FLOOR OR ROOF ASSEMBLY TO REMAIN

THE CONTRACTOR SHALL INFILL THE OPENING WITH

MATERIALS TO MAINTAIN DESIGNATED FIRE OR SMOKE RATING

AS INDICATED BELOW:

A: WHERE OPENINGS ARE ACCESSIBLE TO FOOT

TRAFFIC, OR EXPOSED TO VIEW, OR ARE GREATER

THAN 2" THE OPENING MUST BE FILLED WITH A

CONCRETE SYSTEM SIMILAR TO EXISTING.

B: AREAS NOT EXPOSED TO VIEW CONCEALED BY

CONSTRUCTION OR WHERE THE OPENING IS LESS

THAN 6" THE OPENING MUST BE FILLED WITH A UL

DESIGN SYSTEM AS SPECIFIED IN DIVISION 7 THROUGH

PENETRATION RESISTIVE MATERIAL"

IF ANY EXISTING FIREPROOFING AND/OR RATED ASSEMBLIES TO

REMAIN ARE DAMAGED DURING DEMOLITION, THEY SHALL BE

REPLACED OR REPAIRED TO CONFORM TO THE ORIGINAL FIRE

PROTECTION REQUIREMENTS. THE INTEGRITY OF EXISTING

RATED FLOOR, WALL, BARRIER, AND ROOF ASSEMBLIES TO

REMAIN SHALL BE MAINTAINED THROUGHOUT ALL PHASES OF

CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR TO VERIFY TESTED ASSEMBLIES TO BE USED FOR

REPAIRS.

ALTERNATES

ALTERNATE A01:

PROVIDE NO ATTIC STOCK.

ALTERNATE A02:

REPLACE ALL SCHEDULED 2 x 2 LAY-IN CEILING WITH 2 x 4 LAY-IN

CEILING - ARMSTRONG CORTEGA SECOND LOOK / ANGLED

TEGULAR 15/16 AS A BASIS OF DESIGN.

NEW INTERIOR PARTITION

RATING LEGEND

1 HOUR FIRE BARRIER

COMMENTS TO NEW INTERIOR PARTITION RATING LEGEND

01 - A FIRE-RESISTANT-RATED WALL ASSEMBLY OF MATERIALS

DESIGNED TO RESTRICT THE SPREAD OF FIRE IN WHICH

CONTINUITY IS MAINTAINED. SHAFT, EXIT ENCLOSURES,

EXIT PASSAGEWAY WALLS AND OTHER FIRE BARRIERS.

02 - A VERTICAL ASSEMBLY OF MATERIALS DESIGNED TO

RESTRICT THE SPREAD OF FIRE IN WHICH OPENINGS ARE

PROTECTED. CORRIDOR WALLS AND OTHER FIRE

PARTITIONS.

03 - A FIRE-RESISTANT-RATED WALL HAVING PROTECTED

OPENINGS, WHICH RESTRICTS THE SPREAD OF FIRE AND

EXTENDS CONTINOUSLY FROM THE FOUNDATION TO OR

THROUGH THE ROOF, WITH SUFFICIENT STRUCTURAL

STABILITY UNDER FIRE CONDITIONS TO ALLOW THE

COLLAPSE OF CONSTRUCTION ON EITHER SIDE WITHOUT

THE COLLAPSE OF THE WALL.

04 - SMOKE BARRIERS SHALL BE CONTINUOUS FROM AN

OUTSIDE WALL TO AN OUTSIDE WALL, FROM A FLOOR TO A

FLOOR, OR FROM A SMOKE BARRIER TO A SMOKE

BARRIER, OR BY USE OF A COMBINATION THEREOF.

05 - SMOKE BARRIER - LABELED DOORS ARE NOT REQUIRED.

06 - 1 HOUR FIRE PARTITION - CLASS 'B' OR 'C' DOORS

REQUIRED.

07 - SMOKE BARRIER WITH A 1 HOUR RATING - CLASS 'B' OR 'C'

DOORS REQUIRED.

08 - 2 HOUR FIRE BARRIER - CLASS 'B' DOORS REQUIRED.

09 - SMOKE BARRIER WITH A 2 HOUR RATING - CLASS 'B' OR 'C'

DOORS REQUIRED.

10 - NOTE: ALL CLASS 'B' DOORS ARE TO HAVE A 90 MINUTE

RATING.

1 HOUR FIRE PARTITION

2 HOUR FIRE BARRIER

2 HOUR FIRE WALL

SMOKE BARRIER WITH A 2 HOUR RATING

COMMENTS: 02 / 06

COMMENTS: 01

COMMENTS: 01 / 08

COMMENTS: 03

COMMENTS: 04 / 09

SMOKE BARRIER COMMENTS: 04 / 05

SMOKE BARRIER WITH A 1 HOUR RATING COMMENTS: 04 / 07

HAZARDOUS AREA(S) COMMENTS:

DEFINITIONS

OWNER: U.S. DEPARTMENT OF VETERANS AFFAIRS

REPRESENTED BY THE CONTRACTING OFFICERS

REPRESENTATIVE (COR).

GC: GENERAL CONTRACTOR

CONTRACTOR:GENERAL CONTRACTOR

A/E: THE ARCHITECT AND ENGINEER(S) OF RECORD.

AHJ: THE AUTHORITY HAVING JURISDICTION - WHICH

IS THE OWNER.

UTILITY NOTES

CALL BEFORE YOU DIG:

TEXAS ONE CALL PARTICIPANTS REQUEST A MINIMUM 48 HOURS

NOTICE BEFORE YOU DIG, DRILL OR BLAST - STOP AND CALL:

TEXAS ONE CALL SYSTEM / 1-800-DIG-TESS (344-8377). THE

GENERAL CONTRACTOR IS TO COORDINATE WITH THE FACILITY

OWNER.

UTILITY LOCATION NOTICE:

THE LOCATION OF EXISTING UTILITIES SHOWN IN THESE

CONSTRUCTION DOCUMENTS ARE APPROXIMATE AND BASED ON

EXISTING PLANS AND DATA FURNISHED BY THE UTILITY

COMPANIES. IT REMAINS THE RESPONSIBILITY OF THE GENERAL

CONTRACTOR AND HIS SUB-CONTRACTORS TO VERIFY THE

LOCATION AND DEPTH OF ALL EXISTING UTILITIES THAT MAY BE

IN CONFLICT WITH THE PLANNED CONSTRUCTION. ANY DAMAGE

TO THE EXISTING UTILITIES SHALL BE REPAIRED AT THE

GENERAL CONTRACTOR'S EXPENSE, AT NO ADDITIONAL COST TO

THE OWNER OR A/E TEAM.

ATTIC STOCK

THE GC SHALL PROVIDE ATTIC STOCK AS FOLLOWS:

01 - 5% OF THE TOTAL SQUARE FOOTAGE OF CARPET.

02 - 5% OF THE TOTAL SQUARE FOOTAGE OF VCT.

03 - 5% OF THE TOTAL LINEAR FOOTAGE OF RUBBER BASE.

04 - 5% OF THE TOTAL SQUARE FOOTAGE OF WALL AND

FLOOR TILE.

05 - 5% OF THE TOTAL SQUARE FOOTAGE OF 2 X 2 LAY-IN

CEILING TILE.

THE GENERAL CONTRACTOR SHALL PROVIDE A LINE ITEM IN

THEIR BID FOR THIS MATERIAL EXCLUDING LABOR TO INSTALL.

THE GENERAL CONTRACTOR IS TO COORDINATE THE STORAGE

LOCATION WITH THE OWNER.

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

F1 ABBREVIATIONS AND ANNOTATIONS LEGEND F6 PROJECT SCOPE

E6 PROJECT DATA AND CODE INFO

D1 GENERAL PROJECT NOTES D3 CONTRACTOR RESPONSIBILITIES

E5 DEMOLITION GENERAL NOTES

F3 CUTTING AND PATCHING GENERAL NOTES F5 ALTERNATES

/2

/4

/2

/4

/8

/1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

/8

EA:CLIENT:

P R

O J E

C T

N U

M B

E R

1 2 3 4 5 6 7 8

674-21-101

A-001

INDEX AND GENERAL

INFORMATION

RECONFIGURE

OUTPATIENT REHAB

MEDICINE

REV 01 / 10-17-2022 MDM RLS

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS

76504

REV 01 / 10-17-2022

EA04.0101

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

E

A .0

F4 NEW INTERIOR PARTITION RATING LEGEND

A4 DEFINITIONS

B4 UTILITY NOTES

C4 ATTIC STOCK NOTES

S N

E

HP

ET

SNNYL

R E

G O

R

E T

RA

C

H

I

E

S

T

I

E R

D

T

S

T E X

A6

S

O F

3 3A T

E

T

C

E R

G

REVISION SCHEDULE

No. DESCRIPTION DATE

1 Owner Changes and Corrections 10-17-22

STRUCTURES

S-001 STRUCTURAL NOTES

ELECTRICAL

E-001 ELECTRICAL SYMBOL LEGEND

E-002 ELECTRICAL LIGHT FIXTURE SCHEDULE

E-400 ELECTRICAL PANEL SCHEDULES

E-401 ELECTRICAL PANEL SCHEDULES

PLUMBING

P-001 INDEX AND GENERAL INFORMATION

P-700 SCHEDULES - PLUMBING

PD-106 EXISTING UNDERFLOOR PLAN - DEMOLITION AREAS B/C

- PHASE 4 - PLUMBING

PD-110 EXISTING FLOOR PLAN - DEMOLITION AREA A - PHASE 1

- PLUMBING

PD-111 EXISTING FLOOR PLAN - DEMOLITION AREAS B/C -

PHASE 2 - PLUMBING

PD-113 EXISTING FLOOR PLAN - DEMOLITION AREAS B/C -

PHASE 4 - PLUMBING

PL-114 NEW UNDERFLOOR PLAN - AREA A - PHASE 1 COMPLETE

- PLUMBING

PL-115 NEW UNDERFLOOR PLAN - AREAS B/C - PHASE 2

COMPLETE - PLUMBING

PL-116 NEW UNDERFLOOR PLAN - AREAS B/C - PHASE 3

COMPLETE - PLUMBING

PL-117 NEW UNDERFLOOR PLAN - AREAS B/C - PHASE 4

COMPLETE - PLUMBING

PL-118 NEW FLOOR PLAN - AREA A - PHASE 1 COMPLETE -

PLUMBING

PL-119 NEW FLOOR PLAN - AREAS B/C - PHASE 2 COMPLETE -

PLUMBING

PL-120 NEW FLOOR PLAN - AREAS B/C - PHASE 3 COMPLETE -

PLUMBING

PL-121 NEW FLOOR PLAN - AREAS B/C - PHASE 4 COMPLETE -

PLUMBING

F7 INDEX TO DRAWINGS

S-101 FIRST FLOOR (L1) - OVERALL FLOOR PLAN

S-106 MOBILITY GYM LOADING

S-108 BASEMENT WHEELCHAIR LIFT LOADING

S-200 ROOF PLAN

MEDICAL EQUIPMENT

QH-114 MEDICAL EQUIPMENT PLAN A - PHASE 1 COMPLETE

QH-116 MEDICAL EQUIPMENT PLAN AREAS B/C - PHASE 3

COMPLETE

QH-400 MEDICAL EQUIPMENT AREAS A - PHASE 1 ENLARGED

QH-401 MEDICAL EQUIPMENT AREAS B/C - PHASE 3 ENLARGED

MECHANICAL

M-001 INDEX AND GENERAL INFORMATION - MECHANICAL

M-701 SCHEDULES - MECHANICAL

M-702 SCHEDULES - MECHANICAL

M-801 DETAILS - MECHANICAL

M-802 DETAILS - MECHANICAL

M-803 DETAILS - MECHANICAL

MH-114 NEW FLOOR PLAN AREA A - PHASE 1 COMPLETE - HVAC

MH-115 NEW FLOOR PLAN AREAS B/C - PHASE 2 COMPLETE -

HVAC

MH-116 NEW FLOOR PLAN AREAS B/C - PHASE 3 COMPLETE -

HVAC

MH-117 NEW FLOOR PLAN AREAS B/C - PHASE 4 COMPLETE -

HVAC

MH-118 PARTIAL FIRST, SECOND, AND ROOF PLAN -

MECHANICAL

MH-119 AIR HANDLING UNIT ELEVATIONS - MECHANICAL

MH-120 NEW FLOOR PLAN - AREA A - DEDICATED AHU - MECH

MI-901 CONTROLS - MECHANICAL

MI-902 CONTROLS - MECHANICAL

EL-100 NEW CEILING PLAN AREA A - PHASE 1 COMPLETE -

LIGHTING

EP-100 NEW FLOOR PLAN AREA A - PHASE 1 COMPLETE -

POWER

EP-101 NEW FLOOR PLAN AREAS B/C - PHASE 2 COMPLETE -

POWER

EP-102 NEW FLOOR PLAN AREAS B/C - PHASE 3 COMPLETE -

POWER

EP-103 NEW FLOOR PLAN AREAS B/C - PHASE 4 COMPLETE -

POWER

FIRE ALARM / FIRE PROTECTION

FA-107

FA-108

FA-109

FP-106

FP-107

FP-108

FP-109

TN-001

TN-109

TN-400

FIRE ALARM CLG PLAN AREAS B/C - PHASE 2

FIRE ALARM CLG PLAN AREAS B/C - PHASE 3

FIRE ALARM CLG PLAN AREAS B/C - PHASE 4

FIRE PROTECTION CLG PLAN AREA 1 - PHASE 1

FIRE PROTECTION CLG PLAN AREAS B/C - PHASE 2

FIRE PROTECTION CLG PLAN AREAS B/C - PHASE 3

FIRE PROTECTION CLG PLAN AREAS B/C - PHASE 4

TECH GENERAL NOTES AND SYMBOLS LEGEND

TECH NEW FL PLAN AREAS B/C - PHASE 4

TECH - ENLARGED PLANS

TECHNOLOGY

MmCcomas Image

DNDNDNDNDNDNDNDNDNDNDNDN

P

Y

2 3 4 4' 5 6 7 8

G

F

E

YYY

YYY

K

H

G'

L

J

20 21 22 23 24 25 26

B C

B C

A B

A B

97 SF

SUPER.

OFFICE

79 SF

MEN

99 SF

IDF

244 SF

CONF. /

BREAK

RM.

93 SF

SUPER.

OFFICE

97 SF

SUPER.

OFFICE

96 SF

SUPER.

OFFICE

100 SF

SUPER.

OFFICE

68 SF

STOR.

89 SF

COPY

101 SF

TELE.

HEALTH

125 SF

PMRS

CHIEF

31 SF

STORAGE

118A

100 SF

AO

79 SF

SECTRY

79 SF

MANG.

ANALYST

79 SF

WOMEN

3913 SF

PT / KT /

MOBILITY

GYM

231 SF

RECEPTION

163 SF

REHAB

EXAM

162 SF

REHAB

EXAM

167 SF

REHAB

EXAM

164 SF

REHAB

EXAM

159 SF

REHAB

EXAM

166 SF

MENTAL

HEALTH

EXAM

156 SF

SPEECH

EXAM

116 SF

SPEECH

EXAM

35 SF

HAC

837 SF

WAITING

170 SF

WOMEN'S

LOCKERS

66 SF

EXERCISE

RM.

109B

64 SF

EXERCISE

RM.

122B

89 SF

SHOWERS

122C

237 SF

WOMEN'S

TOILET

RM.

122D

88 SF

SHOWERS

109C

238 SF

MEN'S

TOILET

RM.

109D

170 SF

MEN'S

LOCKERS

73 SF

CORR.

109A

73 SF

CORR.

122A

65 SF

ELECT.

100 SF

OFFICE

137 SF

CORRIDOR

105B

114 SF

OFFICE

239 SF

BREAK

RM.

56 SF

VESTIBULE

170 SF

CONFERENCE

RM.

30 SF

STOR.

130 SF

GROUP

OFFICE

144 SF

WOMEN'S

RR

102 SF

AO

108 SF

OFFICE

145 SF

MEN'S RR

43 SF

ELECTRICAL

101A

86 SF

OFFICE

144 SF

LOBBY

104 SF

IDF

94 SF

CHIEF OF

PHARMACY

94 SF

AO

93 SF

OFFICE

94 SF

OFFICE

258 SF

SPEECH

EXAM

111 SF

SPEECH

EXAM

20 SF

IT

ELECTRONICS

460 SF

CORRIDOR

165 SF

CORRIDOR

277 SF

CORRIDOR

104 SF

EXAM RM.

216 SF

CORRIDOR

211 SF

CORRIDOR

894 SF

CORRIDOR

CB8

379 SF

VAULT

100 SF

OFFICE

103 SF

TECH

WORK

AREA

797 SF

STERILE

COMPOUND

3397 SF

PHARMACY

322 SF

RECEIVING

155 SF

COVID

WORK

ROOM

105C

87 SF

STORAGE

23 SF

STOR.

76 SF

RECEPT.

40 SF

HAC

562 SF

CORRIDOR

CB8

PLAN NORTH

466 SF

SPS WORK

RM.

443 SF

CORRIDOR

CB12

102 SF

LOGISTICS

WORK RM.

819 SF

OT / ADL

491 SF

STAGING /

STORAGE /

DISTRIBUTION

95 SF

TELE

HEALTH

28 SF

IDF

29 SF

ELEC.

821 SF

CORRIDOR

118 SF

SPEECH

EXAM

UP

103 SF

LOGISTICS

WORK RM.

10A

209 SF

LOGISTICS

WORK RM.

10B

NOT IN CONTRACT

NOT IN CONTRACT

N O

T I N

C O

N T

R A

C T

F E

FE

FE

FE

F E

FE

FE

F E

FEFE

240 SF

BMS

CONTROL

RM

149 SF

EQUIP.

STOR. RM

80 SF

HAC

480 occupants

280 OCCUPANTS

280 OCCUPANTS

480 OCCUPANTS

480 OCCUPANTS

480 OCCUPANTS

320 OCCUPANTS

480 OCCUPANTS

480 OCCUPANTS

320 OCCUPANTS

480 OCCUPANTS280 OCCUPANTS

480 OCCUPANTS

480 OCCUPANTS

480 OCCUPANTS480 OCCUPANTS

240 OCCUPANTS

480 OCCUPANTS

240 OCCUPANTS

240 OCCUPANTS

185' - 0 1/2"

185'

108'

185'

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

AREA LEGEND

EXISTING OCCUPIED SPACE - NOT IN SCOPE

STORAGE SPACE - PROJECT SCOPE AREA

EXISTING WALLS TO REMAIN

OCCUPIED SPACE

LIFE SAFETY SYMBOLS

EXIT DIRECTION OF

TRAVEL

EXIT ROUTE

COMMENCEMENT

FIRE EXTINGUISHER

LOCATION

EXIT SIGN

EGRESS EXIT

XXX

EXISTING FIRE

EXTINGUISHER

LOCATION

XFE

FE REFER TO C1 / A-701

OCCUPANT LOADS

BASEMENT:

A - PHARMACY / AREA 'A' = 5,348 sf / 150 = 36 OCCUPANTS

B - OFFICE / AREA 'A' = 1,135 SF / 150 = 8 OCCUPANTS

C - CONF / BREAK RM / AREA 'A' = 409 SF / 15 = 27 OCCUPANTS

D - OFFICE / WORK RMS / AREAS 'B' AND 'C' = 5,300 SF / 150 =

35 OCCUPANTS

E - LOCKER ROOMS / AREA 'B' = 646 SF / 50 = 13 OCCUPANTS

F - STORAGE / HAC / SHIPPING / LOGISTICS / AREAS 'A', 'B', 'C'

= 2,280 SF / 300 = 8 OCCUPANTS

G - OT / ADL / MOBILITY GYM / AREAS 'B' AND 'C' = 4,729 SF / 50

= 95 OCCUPANTS

H - CONF & BREAK RM / AREA 'B' = 244 SF / 15 = 16

OCCUPANTS

I - OPEN OFFICE IN CORRIDORS / AREA 'B' = 16 OCCUPANTS

J - WAITING & RECEPTION / AREA 'C' = 1,108 SF / 15 = 74

OCCUPANTS

TOTAL OCCUPANT LOAD = 328

/2

/4

/2

/4

/8

/1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

/8

EA:CLIENT:

P R

O J E

C T

N U

M B

E R

1 2 3 4 5 6 7 8

674-21-101

A-002

LIFE SAFETY PLAN RECONFIGURE

OUTPATIENT REHAB

MEDICINE

REV 01 / 10-17-2022 Checker Author

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS

76504

REV 01 / 10-17-2022

EA04.0101

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

E

A .0

F8

KEY PLAN FOR SHEET A-002

1/8" = 1'-0"

LIFE SAFETY PLAN

F1

FULLY SPRINKLERED FACILITY

D8

LIFE SAFETY AREA LEGEND

C8

LIFE SAFETY SYMBOLS

B8

LIFE SAFETY OCCUPANT LOADS

S N

E

HP

ET

SNNYL

R E

G O

R

E T

RA

C

H

I

E

S

T

I

E R

D

T

S

T E X

A6

S

O F

3 3A T

E

T

C

E R

G

REVISION SCHEDULE

No. DESCRIPTION DATE

1 Owner Changes and Corrections 10-17-22

UPUP

UP

UP

A - GRAY INDICATES EXISTING WALLS TO REMAIN.

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

A

P

Q

S

T

U

V

W

X

Y

1816 17 19

G

F

E

15YYY

K

H

R L

J

A B

A B

598 SF

CORRIDOR

160 SF

ELEVATOR

EQUIPMENT

BC102

1892 SF

MECHANICAL

ROOM

BC101

32 SF

IDF

BC103

1151 SF

MSD&E

PURCHASERS

BC104

122 SF

HAC

BC105

436 SF

RESTROOM,

MEN

BC127B

69 SF

ELECTRICAL

ROOM

BC106

490 SF

CORRIDOR

CB14

306 SF

LOCKER

ROOM,

MEN

BC127

143 SF

STAFF

PHYSIATRIST

BC128

164 SF

PHYSIATRY

CLINIC

BC108

695 SF

OCCUPATIONAL

THERAPY

BC109

286 SF

SPS ADMIN

BC126

124 SF

EXAM

ROOM

BC110A

222 SF

PHYSIATRIC

CLINIC

RECEPTION

BC110

134 SF

EXAM

ROOM

BC125

121 SF

OFFICE

BC109B

135 SF

OFFICE/

EXAM

BC109A

689 SF

LOCKER

ROOM,

WOMEN

BC124

211 SF

PHYSIATRY

BC115

113 SF

STAFF

PHYSIATRIST

BC111

188 SF

CHIROPRACTIC

OFFICE

BC107

152 SF

CHIROPRACTIC

EXAM

ROOM

BC107A

1402 SF

CORRIDOR

CB16

552 SF

CORRIDOR

CB15

148 SF

SUPERVISOR

OFFICE

PHYSICAL

THERAPY

BC114A

137 SF

SUPERVISOR

OFFICE

KINESIOTHERAPY

THERAPY

BC114B

102 SF

EXAM

ROOM/CHRIOPRACTOR

BC112

168 SF

SLP LAB &

TREATMENT

RM.

BC116D

25 SF

ELECTRICAL

ROOM

BC123

137 SF

EXAM

ROOM

BC122B

141 SF

MANAGEMENT

ANALYST

BC113

162 SF

PM&RS AO

BC114

149 SF

SUPERVISOR

OFFICE

OCCUPATIONAL

THERAPY

BC114C

78 SF

COMPUTER

ROOM

BC116C

110 SF

EXAM

ROOM

BC122A

98 SF

STAFF

PHYSIATRIST

BC122

153 SF

TREATMENT

ROOM

BC116E

186 SF

SPEECH &

LANGUAGE

PATHOLOGY

BC116135 SF

EXAM

ROOM

BC119B

195 SF

SECRETARY

BC119277 SF

PSYCHOLOGIST

BC121

126 SF

SUPERVISORY

SPEECH

PATHOLOGIST

BC116B

166 SF

CHIEF PM

& RS

BC119A

129 SF

SPEECH

PATHOLOGIST

BC116A

75 SF

HAC

STORAGE

BC118

119 SF

COPY

ROOM

197 SF

SUPERVISORY

AMSA

BC120

122 SF

OFFICE

BC152

89 SF

STORAGE

BC153

103 SF

ANTE

BD103E

PLAN NORTH

NOT IN CONTRACT

LIMITED WORK IN THIS

AREA - REFER TO MECH

SHEET MH-114.

NOT IN CONTRACT

/2

/4

/2

/4

/8

/1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

/8

EA:CLIENT:

P R

O J E

C T

N U

M B

E R

1 2 3 4 5 6 7 8

674-21-101

A-100

EXISTING FLOOR PLAN -

AREA A

RECONFIGURE

OUTPATIENT REHAB

MEDICINE

REV 01 / 10-17-2022 MDM RLS

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS

76504

REV 01 / 10-17-2022

EA04.0101

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

E

A .0

F8

KEY PLAN FOR SHEET A-100

FULLY SPRINKLERED FACILITY

A8

GENERAL NOTES FOR SHEET A-100

1/8" = 1'-0"

EXISTING FLOOR PLAN - AREA

F5

S N

E

HP

ET

SNNYL

R E

G O

R

E T

RA

C

H

I

E

S

T

I

E R

D

T

S

T E X

A6

S

O F

3 3A T

E

T

C

E R

G

REVISION SCHEDULE

No. DESCRIPTION DATE

1 Owner Changes and Corrections 10-17-22

A - GRAY INDICATES EXISTING WALLS TO REMAIN.

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

B

P

X

Y

2 3 4 4' 5

G

F

E

K

H

G'

L

J

20 21 22 23

A B

A B

B C

B C

104 SF

ELEC.

ROOM

BD110

87 SF

SPS CHIEF

BD105

63 SF

CART LIFT

MECHANICAL

RM

BD104

99 SF

SUPPLY

ROOM

BD107

104 SF

SPS ASST.

CHIEF/RME

COORD.

BD106A

106 SF

SPS

BD106 55 SF

ELE.

BD109

1104 SF

CORRIDOR

CB21

96 SF

PROSTETICS

OFFICE

BB130A

165 SF

PT OFFICE

BB127A 1408 SF

PHYSICAL

THERAPY

BB127

288 SF

SUPPLY

ROOM

BB130

1194 SF

CORRIDOR

CB12

13 SF

FIRE

EQUIPMENT

142 SF

KINESIOTHERAPY

OFFICE

BB125

126 SF

PM&RS

STORAGE

BB129B

322 SF

PM&RS

STORAGE

BB129A

943 SF

KINESIOTHERAPY

BB128

2067 SF

THERAPEUTIC

POOL

BB129

51 SF

LINEN

ROOM

BB129E

39 SF

HOUSEKEEPING

BB115E

271 SF

PM&RS

SUPPLY

ROOM

BB129C

301 SF

PHARMACY

FLOOR

BB115K

70 SF

DRESSING

ROOM

BB129F

109 SF

OFFICE

BB115C

128 SF

OFFICE

BB115D

199 SF

PUMP

ROOM

BB129G

172 SF

ASSISTANT

CHIEF

PHARMACY

SERVICE

BB112E

103 SF

PROGRAM

SPECIALIST

BB112F

129 SF

CHIEF

PHARMACY

SERVICE

BB112G

210 SF

CONT.

SUB.

VAULT

BB115A

110 SF

CLINICAL

PHARMACIST

BB113B

89 SF

LEAD

CONT.

SUB.

OFFICER

BB112H

89 SF

OFFICE

BB115B

58 SF

RESTROOM

BB113D

112 SF

ASSOC.

CHIEF

CLINICAL

COORD.

BB112D 217 SF

CONFERENCE

ROOM

BB113

273 SF

PHARMACY

SERVICE

BB

178 SF

CORRIDOR

166 SF

IDF

BB110

206 SF

PHARMACY

SERVICE

OFFICE

BB112

270 SF

BREAKROOM

BB113E

130 SF

AO OFFICE

BB112B

140 SF

CLERKS

BB112A

100 SF

ADPAC

BB113A

366 SF

CORRIDOR

CB8

116 SF

STAFF

ONLY

BB104

67 SF

RADIOACTIVE

WASTE

STORAGE

BB114A

486 SF

TELEPHONE

BB111

91 SF

MECHANICAL

BB11A1

435 SF

MECH

ROOM

BB114

63 SF

VESTIBULE

BD108F

64 SF

ANTE

BD108G

18 SF

STO.

BB112C

552 SF

PRE-PACK

BB115J

PLAN NORTH

NOT IN CONTRACT

NOT IN CONTRACT

LIMITED WORK IN THIS

AREA - REFER TO MECH

SHEET MH-114.

THE YELLOW CROSS HATCH

INDICATES THE LOCATION

OF AN EXISTING EXPANSION

JOINT (FLOOR, WALL CEILING)

TO BE REMOVED AND REPLACED.

/2

/4

/2

/4

/8

/1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

/8

EA:CLIENT:

P R

O J E

C T

N U

M B

E R

1 2 3 4 5 6 7 8

674-21-101

A-101

EXISTING FLOOR PLAN -

AREA B

RECONFIGURE

OUTPATIENT REHAB

MEDICINE

REV 01 / 10-17-2022 MDM RLS

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS

76504

REV 01 / 10-17-2022

EA04.0101

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

E

A .0

A8

GENERAL NOTES FOR SHEET A-101

F8

KEY PLAN FOR SHEET A-101

1/8" = 1'-0"

EXISTING FLOOR PLAN - AREA B

F5

S N

E

HP

ET

SNNYL

R E

G O

R

E T

RA

C

H

I

E

S

T

I

E R

D

T

S

T E X

A6

S

O F

3 3A T

E

T

C

E R

G

REVISION SCHEDULE

No. DESCRIPTION DATE

UP

DN

DN

A - GRAY INDICATES EXISTING WALLS TO REMAIN.

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

C

P

6 7 8

F

E

K

H

G'

L

J

23 24 25 26

B C

B C

102 SF

TRASH

ROOM

BD112

104 SF

ELEC.

ROOM

BD110

625 SF

CORRIDOR

CB22

118 SF

A5 OFFICE

BD111A

125 SF

SUPERVISOR

MSD&E

BB126B

155 SF

CONTROL

ROOM

BA108A

242 SF

MSD&E

ADMIN

BB126

126 SF

SUPERVISOR

MSD&E

BB126A

370 SF

CORRIDOR

CB10

208 SF

STAIR 3

BS-3

5 SF

FIRE

EQUIPMENT

142 SF

KINESIOTHERAPY

OFFICE

BB125

455 SF

KINESIOTHERAPY

BB124

1031 SF

WAITING/RECEPTION

BB120

39 SF

HOUSEKEEPING

BB115E

28 SF

IDF

BB117

392 SF

PHARMACY

FLOOR

BB115L

358 SF

PHARMACY

FLOOR

BB115M

128 SF

PHARMACY

FLOOR

BB115N

29 SF

ELEC.

BB116

337 SF

STERALIZATION

ROOM

BB115F

126 SF

MEN

BA107

146 SF

VCS

SUPPORT

OPERATION

BA109

118 SF

WOMEN

BA106

1180 SF

PHARMACY

FLOOR

BB115

39 SF

ELECTRICAL

ROOM

BA104464 SF

CORRIDOR

CB3

14 SF

COMM.

BA103

4230 SF

CORRIDOR

CB7

5 SF

F.E.

NO #

170 SF

IV

BB115H

714 SF

CORRIDOR

CB4

BC122E

107 SF

VEST.

BB115G

261 SF

WORK

AREA

BB115I

552 SF

PRE-PACK

BB115J

N O

T I N

C O

N T

R A

C T

PLAN NORTH

NOT IN CONTRACT

NOT IN CONTRACT

/2

/4

/2

/4

/8

/1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

/8

EA:CLIENT:

P R

O J E

C T

N U

M B

E R

1 2 3 4 5 6 7 8

674-21-101

A-102

EXISTING FLOOR PLAN -

AREA C

RECONFIGURE

OUTPATIENT REHAB

MEDICINE

REV 01 / 10-17-2022 Checker Author

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS

76504

REV 01 / 10-17-2022

EA04.0101

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

E

A .0

F8

KEY PLAN FOR SHEET A-102

A8

GENERAL NOTES FOR SHEET A-102

1/8" = 1'-0"

EXISTING FLOOR PLAN - AREA C

F5 FULLY SPRINKLERED FACILITY

S N

E

HP

ET

SNNYL

R E

G O

R

E T

RA

C

H

I

E

S

T

I

E R

D

T

S

T E X

A6

S

O F

3 3A T

E

T

C

E R

G

REVISION SCHEDULE

No. DESCRIPTION DATE

1 Owner Changes and Corrections 10-17-22

UP

02 41 00.C45

02 41 00.C4602 41 00.C46

02 41 00.C47

02 41 00.C48

02 41 00.C49

ENAPAY, LLC

MESQUITE, TX 75149

207 WEST MAIN STREET

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

OLIN E. TEAGUE VETERANS' CENTER

TEMPLE, TEXAS 76504

1901 VETERANS MEMORIAL DRIVE

MR. TYRONE BENNET

T. 254.743.0938

MOYE CONSULTING

IRIVING, TEXAS 75038

1255 CORPORATE DRIVE - SUITE 100

MR. DANIEL LeCLAIR, PE T. 972.887.5553

SSR, INC.

3700 W. SAM HOUTON PARKWAY S

SUITE 200

HOUSTON, TEXAS 77042

MR. STEVE STENACKER

T. 713.353.2963

SW ASSOCIATES CONSULTING ENGINEERS

1700 PACIFIC AVE., SUITE 2100

DALLAS, TEXAS 75201

MR. MIKE ASHCRAFT, PE

T. 214.397.0211

IKERD

DECATUR, TX 76234

1604 W BUSINESS 380, SUITE 100

MR. WILL IKERD, PE

T. 214.382.9811

PHASE 01

A B

A B

598 SF

CORRIDOR

160 SF

ELEVATOR

EQUIPMENT

BC102

1892 SF

MECHANICAL

ROOM

BC101

32 SF

IDF

BC103

1151 SF

MSD&E

PURCHASERS

BC104

122 SF

HAC

BC105

436 SF

RESTROOM,

MEN

BC127B

69 SF

ELECTRICAL

ROOM

BC106

490 SF

CORRIDOR

CB14

306 SF

LOCKER

ROOM,

MEN

BC127

143 SF

STAFF

PHYSIATRIST

BC128

164 SF

PHYSIATRY

CLINIC

BC108

695 SF

OCCUPATIONAL

THERAPY

BC109

286 SF

SPS ADMIN

BC126

124 SF

EXAM

ROOM

BC110A

222 SF

PHYSIATRIC

CLINIC

RECEPTION

BC110

134 SF

EXAM

ROOM

BC125

121 SF

OFFICE

BC109B

135 SF

OFFICE/

EXAM

BC109A689 SF

LOCKER

ROOM,

WOMEN

BC124

211 SF

PHYSIATRY

BC115

113 SF

STAFF

PHYSIATRIST

BC111

188 SF

CHIROPRACTIC

OFFICE

BC107

152 SF

CHIROPRACTIC

EXAM

ROOM

BC107A

1402 SF

CORRIDOR

CB16

552 SF

CORRIDOR

CB15

148 SF

SUPERVISOR

OFFICE

PHYSICAL

THERAPY

BC114A

137 SF

SUPERVISOR

OFFICE

KINESIOTHERAPY

THERAPY

BC114B

102 SF

EXAM

ROOM/CHRIOPRACTOR

BC112

168 SF

SLP LAB &

TREATMENT

RM.

BC116D

25 SF

ELECTRICAL

ROOM

BC123

137 SF

EXAM

ROOM

BC122B

141 SF

MANAGEMENT

ANALYST

BC113

162 SF

PM&RS AO

BC114

149 SF

SUPERVISOR

OFFICE

OCCUPATIONAL

THERAPY

BC114C

78 SF

COMPUTER

ROOM

BC116C

110 SF

EXAM

ROOM

BC122A

98 SF

STAFF

PHYSIATRIST

BC122

153 SF

TREATMENT

ROOM

BC116E

186 SF

SPEECH &

LANGUAGE

PATHOLOGY

BC116135 SF

EXAM

ROOM

BC119B

195 SF

SECRETARY

BC119

277 SF

PSYCHOLOGIST

BC121

126 SF

SUPERVISORY

SPEECH

PATHOLOGIST

BC116B

166 SF

CHIEF PM

& RS

BC119A

129 SF

SPEECH

PATHOLOGIST

BC116A

75 SF

HAC

STORAGE

BC118

119 SF

COPY

ROOM

197 SF

SUPERVISORY

AMSA

BC120

122 SF

OFFICE

BC152

89 SF

STORAGE

BC153

103 SF

ANTE

BD103E

P

Q

S

T

U

V

W

X

1816 17 19

F

E

15YYY

K

H

R L

J

NOT IN CONTRACT

NOT IN CONTRACT

P H

O T

O S

D

D

P H

O T

O D

P H

O T O

A A

PHOTO

B1, B2

P H

O T

O A

P H

O T O

A

PHOTO

B3

PHOTO

B4

PHOTO

C1, C2

PHOTO

C3, C4

PHOTO

D1

LIMITED WORK IN THIS

AREA - REFER TO MECH

SHEET MH-114.

THE RED WALL INDICATES A TEMPORARY 1

HOUR WALL TO BE BUILT AND REMOVED BY

THE GENERAL CONTRACTOR. REFER TO

A-700 WALL TYPE 'B'.

/2

/4

/2

/4

/8

/1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

/8

EA:CLIENT:

P R

O J E

C T

N U

M B

E R

1 2 3 4 5 6 7 8

674-21-101

A-103

EXISTING FLOOR PLAN -

DEMOLITION AREA A -

PHASE 1

RECONFIGURE

OUTPATIENT REHAB

MEDICINE

REV 01 / 10-17-2022 MDM RLS

1901 VETERANS MEMORIAL DRIVE TEMPLE, TEXAS

76504

REV 01 / 10-17-2022

EA04.0101

R E

C O

N F

IG

U

R E

O U

T P

A T

IE

N

T R

E H

A B

M E

D

IC

IN

E

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

R E

V

E

A .0

A8 GENERAL NOTES FOR SHEET A-103

F8 KEY PLAN FOR SHEET A-103

FULLY SPRINKLERED FACILITY

E8 KEYNOTE LEGEND FOR SHEET A-103

D8 DEMOLITION LEGEND FOR SHEET A-103

KEYNOTE LEGEND

KEY VALUE KEYNOTE TEXT

02 41 00.C45 The Dashed Lines Indicate Existing Wall Construction to be Removed in its Entirety from Floor to the Structure above - Including Doors, Door Frames, Borrowed Lights, Bumper Guards, Handrails, and Associated Mechanical / Electrical Work. Prepare the Areas for New Construction.

02 41 00.C46 The Dashed Lines Indicate Existing Door, Door Frame and Borrowed Light / Frame Assembly to be Removed.

Patch the Opening with a Partition Type to Match the Existing Wall. Refer to the New Floor Plan for the New Partition

02 41 00.C47 The Dashed Lines Indicate a Portion of the Existing Wall to be Removed for a New Opening in an Existing Partition as Required to Install a New Door and / or Borrowed Light Assembly.

02 41 00.C48 The Dashed Lines Indicate Existing Casework, Millwork, Counters, Shelving, Equipment and Supports…