2380D8R5 1 drawings.pdf

PDF 1 MB Posted

Attached to
N046--580-25-2-5161-0036 Reverse Osmosis and DI Water
Solicitation number
36C25625Q0479
Issued by

About this file

These are STERIS design drawings for the Sterile Processing Department equipment layout at the Houston VA Medical Center, depicting two equipment configuration options: an opening day option and a future option. The drawings include detailed floor plans, equipment lists, wall opening elevations, floor sink locations, and installation details for medical equipment such as washers/disinfectors, sterilizers, storage systems, and support infrastructure. The comprehensive set includes four pages of technical drawings specifying precise equipment placement, recommended clearances, and installation requirements for medical equipment in the VA facility's sterile processing area, with specific attention to equipment positioning, electrical and plumbing considerations, and workflow optimization.

The equipment list encompasses multiple STERIS and Amsco branded medical devices, including loading cars, case carts, dosing systems, reprocessing sinks, drying cabinets, pass-through windows, conveyor systems, transfer carts, sonic irrigators, ultrasonic cleaners, prep and pack workstations, steam sterilizers, and automated storage systems. The drawings are dated 28 August 2019, with a revision on 22 February 2021, and are designed for the Houston VA Medical Center located in Houston, Texas, with a scale of 3/16" = 1'-0" and drawn by STERIS Planning & Design Group.

View the file

Other files

File Type Posted
RFIS COMPLETED 3.docx DOCX document
AMENDED SCHEDULE.docx DOCX document
36C25625Q0479 0004.docx DOCX document
AMENDMENT 36C25625Q0479 0003.docx DOCX document
RFIS COMPLETED 2.docx DOCX document
AMENDMENT 36C25625Q0479 0002.docx DOCX document
HST-100-0BAR.pdf PDF
RO AND DI WATER SYSTEM - PRE-BID RFIs- COMPLETE.docx DOCX document
AMENDMENT 36C25625Q0479 0001.docx DOCX document
Service Contract Act WD 2015-5233.txt TXT text file
WAGE DETERMINATION - TX20250253 01-03-2025 - CONSTRUCTION.txt TXT text file
36C25625Q0479 - SOLICITATION.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

SS SS

101112

G

H

BB-285

SUPPLY

PROCESSING AND

DISTRIBUTION

BB-230D

FEMALE LOCKER

BB-230E

TOILET - FEMALE

BB-230

LOCKER

BB-260A

EQ STORAGE &

TEST

BB-220B

EQ WASH

BB-261B

HAC

BB-220

DECONTAMINATION

BB-210

PREP/ASSEMBLY

BB-261

STERILE STORAGE

BB-260D

T-5 ROOM

S5505D

F0230

F0230

F0230 F0230

F0230F0230

F0230

F0230

F0230

F0230

A5075

A5080

A5075

A5080

A1014

A1014

BB-230C

ELEVATOR MACH.

F3200

F3200

A1014

A5077

A5077

A5077

A5077

A5077

M1825

M1825

M1825

M1825

M1825

M1825 M1825

M1825

M1825

M1825

FEC

FEC

S5505D S5505C S5505C S5505B S5505B S5505A

A5075

A5080

FEC

FEC

FEC

FEC

BB-220C

HAC

BB-231A

ANTE ROOM

M1801

A1195XE

A1195XE

S2635E

S2635E

S2635E

A1195XE

A1195XE

FRONT

U0002

F R O N

TU0002

1818181818

1818181818

1818181818

F R O N

TU0002

S9610S9610

S9610 S9610

S9610S9610

S9610 S9610

S9610

S9610

S2635XE

M I N I M U M

P R E F E R R E

DS0235E

S9815

S9815

S9815

S9815

S9815

S9815

S9815

R E C O M M E N D E D

I N S T A L L A T I O N

C L E A R A N C E

R E C O M M E N D E D

I N S T A L L A T I O N

C L E A R A N C E

S3185

A1195X

A1195X

SEISMIC

SEISMIC

S2635A

S0006 S0004C

DECONTAM

S0020 S0026X

S0048

S0026X

S0048

S0020X

S0026X S0026X S0026X

S0048 S0048

S0048 S0048

S0940 S0940

S0940RS0940RS0940R

1818181818

1818181818

MOVED WALL PLAN

EAST 38" TO FIT

EQUIPMENT

MODIFIED WALL AND SHIFT WASHERS

PLAN WEST 3"

FRONT

U0002

FRONT

U0002

FOR EACH WASHER/CART WASHER, A 3" I.D. CONDUIT REQUIRED FROM DETERGENT

PUMP LOCATION(S) TO WASHER LOCATION(S) - NOT PROVIDED BY STERIS

EQUIPMENT LIST

TAG QTY DESCRIPTION

15 14 Amsco 600 Loading Car and Transfer Carriage - 26.5x26.5x63"/Fixed Height

18 29 STERIS Closed Case Cart - 27.5x36x54"/Single Door/Stainless Steel

21 5 Acu-Hold System - Wall Mounted/3 Container

22 7 STERIS Dosing System - 3 Pumps (Included with Washer/Power supplied by Washer)

33 1 Amsco 50 Reprocessing Sink - 3 Bay/97.5" Long/Height Adjustable

34 1 InnoWave Unity Ultrasonic Irrigator - 15 Gallon

A1195X 2 Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)

A1195XE 4 Existing Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)

S0004C 1 Amsco Drying Cabinet - 38"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)

S0006 1 Amsco Drying Cabinet - 29"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)

S0020 1 STERIS Automated Pass-Through Window - MDR/CSSD Application (28x45" Window)

S0020X 1 SCS Motorized Return Conveyor System - 4 Module/Return Door/Flush Mounted

S0026X 5 SCS Load/Unload Conveyor System - Single Load/Single Unload

S0048 6 Reliance Transfer Cart

S0235E 1 Relocated Existing Amsco 400 Small Steam Sterilizer - 20x20x38" (508x508x965mm)(250L)/Single Door/Recessed/Steam Heat

S0940 2 Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted

S0940R 3 Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted/Reverse Install

S2635A 1 InnoWave PRO Sonic Irrigator - 60 Lumen Capacity

S2635E 3 Existing Caviwave 20-W Ultrasonic Cleaner - Wash/20 Gallon

S2635XE 1 Existing Caviwave Pro 17-DRW Ultrasonic Console - Dry/Rinse/Wash/17 Gallon/Right to Left Workflow

S3185 1 Vision 1327 (Qty. 2) Side by Side Cart and Utensil Washer/Disinfectors - Shared Service/Double Door/Pit Mounted/Steam Heat/Common Service Area Junction Panels

S9610 10 Amsco Deluxe Prep and Pack Workstation - 36x72"/Electric Height Adjustable

S9815 7 Amsco 600 Medium Steam Sterilizer - 26.5x26.5x63" (673x673x1600mm)/Double Sliding Door/Recessed 2 Walls/Steam Heat

U0002 5 Hanel Automated Rotomat Storage System - Model SSC117 (10'-0" Ceiling/5966 lbs Unloaded Weight/16466 lbs Loaded Weight)

REVISION HISTORY

REVISION # DESCRIPTION PLANNER/DATE

UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH

ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021

Planning & Design Group

STERIS

5960 Heisley Road

Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.* THE WALLS AND OR EQUIPMENT SHOWN IN THIS DRAWING HAVE BEEN MOVED/MODIFIED TO ACCOMMODATE MINIMUM RECOMMENDED CLEARANCES FOR STERIS EQUIPMENT

Dr

Ck

Date

Scale

H- D

PARTIAL FLOOR PLAN

STERILE PROCESSING DEPARTMENT

PROPOSED EQUIPMENT LAYOUT - OPENING DAY OPTION

HOUSTON VA MEDICAL CENTER

HOUSTON, TEXAS

3/16" = 1'-0"

28AUG2019

JZT

MK

8R5

S S

S S

S S

S S

S S

S S

S S

S S

S S

SS SS

101112

G

H

J

BB-285

SUPPLY

PROCESSING AND

DISTRIBUTION

BB-220B

EQ WASH

BB-261B

HAC

BB-220

DECONTAMINATION

BB-210

PREP/ASSEMBLY

BB-261

STERILE STORAGE

BB-260D

T-5 ROOM

BB-230C

ELEVATOR MACH.

BB-220C

HAC

BB-231A

ANTE ROOM

20314"

97 8

71 2"

20618"

11 8

93 8

18834"

19114"

93 8

93 8

93 8

93 8

93 8

95 8

51 2"

81 2" WASHER FLOOR

SINK- TYP.3

7212" 7834" 7234" 1958" 6758"

WASHER FLOOR

SINK- TYP.2

EXISTING SONIC

FLOOR SINK

TYP.4

RELOCATED

EXISTING

STERILIZER

FLOOR SINK

STERILIZER

FLOOR SINK

TYP.7

SEE PIT

DETAILS FOR

FLOOR SINK

LOCATIONS

SINK STATION

FLOOR SINK

TYP.2

EXISTING SINK

STATION FLOOR

SINK TYP.4

SONIC

FLOOR

SINK

SONIC

FLOOR

SINK

SINK STATION

FLOOR SINK

12738"

90"130"

41 2"

95 8

41 2"

87 8"

1 4

1878" 1178"

7718" 10934" 5458"

9778" 5078"

3734"

21" Scale: 3/16" = 1' - 0"

SECTION VIEW - 1327 PIT DETAILS

2x2x 3

16" STAINLESS

STEEL ANGLE AROUND

PERIMETER OF PIT

(SEE NOTES 1 AND 2)

FINISHED

FLOOR

RECOMMENDED 8" MIN. (ROUND OR SQUARE) x 6" DEEP

FLOOR SINK WITH 4" O.D. DRAIN OUTLET; DRAIN SHALL

FURNISH FOR 60 U.S. GPM FLOW (SEE NOTES 1 AND 3)

6" MIN. (634" MAX.)

FINISHED FLOOR

TO TOP OF PAD

(TYP. OF 4)

(SEE NOTE 1)

634"

PIT DEPTH

PIT DETAIL NOTES:

1. ALL MATERIAL (INCLUDING CONCRETE, CORNER LEVELING PADS, STAINLESS

STEEL ANGLES, FLOOR SINK) AND LABOR FOR CONSTRUCTION OF PIT TO BE BY

OTHERS THAN STERIS

2. STAINLESS STEEL ANGLES ARE RECOMMENDED BY STERIS; TO BE SUPPLIED AND

INSTALLED BY OTHERS THAN STERIS

3. SLOPE PIT TO DRAIN (1 DEGREE)

CORNER LEVELING PAD

(TYP. OF 4 - SEE NOTE 1)

REVISION HISTORY

REVISION # DESCRIPTION PLANNER/DATE

UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH

ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021

14614" 118"

15 8

22"

412"

22" 412"

1 4

12"

16"

1 4

PIT

FLOOR SINK

12"

1 4"

16"16"

12"

16"

12"

SCALE: 3/16" = 1'-0"

FLOOR SINK LOCATIONS PLAN

SCALE: 3/16" = 1'-0"

PIT DIMENSIONS

Planning & Design Group

STERIS

5960 Heisley Road

Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.

Dr

Ck

Date

Scale

H- D

FLOOR SINKS LOCATION PLAN & PIT DETAILS

STERILE PROCESSING DEPARTMENT

PROPOSED EQUIPMENT LAYOUT - OPENING DAY OPTION

HOUSTON VA MEDICAL CENTER

HOUSTON, TEXAS

3/16" = 1'-0"

28AUG2019

JZT

MK

8R5

1534"4214"4214"87"2458" 30" 2058" 19" 39"

53458"

S0006 S0020

S0004C

S0020X11

S0940 S0940R

Scale: 1/4" = 1' - 0"

FINISHED WALL OPENING ELEVATION - WASHER BARRIER WALL LOAD SIDE

S0940RS0940R

S0940

87" 45"

M I N

R E C O M M E N D E D

T Y P

V E R I F Y

C E I L I N G

H E I G H T

M I N

R E C O M M E N D E D

C E I L I N G

H E I G H T

F O R

D O O R

R E M O V A L

T Y P

12" STRAP BACKING

REQUIRED ON LOAD

AND UNLOAD SIDES

UNDER WALL OPENING

FOR COUNTER SUPPORT

1 4

V E R I F Y

12"

2814" 3178"

S E R V I C E

C L E A R A N C E

A B O V E

F I N I S H E D

F L O O R

T Y P

S

S C

M I N

C E I L I N G

H E I G H T

85 8

T Y P

S

S C

1018" 1178"

35458"

217" 1058" 217" 1058"

S3185

Scale: 1/4" = 1' - 0"

FINISHED WALL OPENING ELEVATION - CART WASHERS UNLOAD SIDE

Scale: 1/4" = 1' - 0"

FINISHED WALL OPENING ELEVATION - CART WASHERS LOAD SIDE

S3185

V E R I F Y

C E I L I N G

H E I G H T

R E C O M M E N D E D

S E R V I C E

C L E A R A N C E

A B O V E

F I N I S H E D

F L O O R

93 4

M I N

R E C O M M E N D E D

S E R V I C E

C L E A R A N C E

A B O V E

F I N I S H E D

F L O O R

93 4

M I N

V E R I F Y

C E I L I N G

H E I G H T

1 4

S0235E

Scale: 1/4" = 1' - 0"

FINISHED WALL OPENING ELEVATION - STERILIZERS LOAD SIDE

Scale: 1/4" = 1' - 0"

FINISHED WALL OPENING ELEVATION - STERILIZERS UNLOAD SIDE

27714"

91 8"

S E R V I C E

C L E A R A N C E

V E R I F Y

C E I L I N G

H E I G H T

01 2"

S9815 S9815 S9815 S9815 S9815 S9815 S9815

5078" 2818" 1278"

S9815 S9815 S9815 S9815 S9815 S9815 S9815

9178" 27714"

91 8"

S E R V I C E

C L E A R A N C E

V E R I F Y

C E I L I N G

H E I G H T

01 2"

SHEET NOTES :

1. AMBIENT TEMPERATURE SHALL NOT EXCEED 104°F.

2. DETERGENT AND SIGNAL LINES NOT TO COME INTO CONTACT WITH HOT SURFACES.

3. EXCESS LENGTH MUST BE CUT BEFORE CONNECTING TO WASHER/STATION TO AVOID FORMING BUNDLES THAT

COULD AFFECT THE DETERGENT INJECTION SYSTEM'S PERFORMANCES.

4. 3"I.D. CONDUIT REQUIRED FROM PUMP LOCATION(S) TO WASHER LOCATION(S)- NOT PROVIDED BY STERIS.

5. ALL 90 DEGREE CONDUIT TURNS MUST USE SWEEPING 90 DEGREE CONNECTIONS. STRAIGHT 90 DEGREE

CONNECTIONS ARE NOT RECOMMENDED.

6. FINAL LOCATION OF RUNS TO BE COORDINATED WITH ARCHITECT, CONTRACTORS, AND STERIS INSTALLATION

PERSONNEL.

7. A MAXIMUM OF TWO WASHERS OR ONE CART WASHER CAN SHARE CHEMICAL CONTAINERS. DEDICATED CONTAINERS

RECOMMENDED FOR EACH WASHER.

8. FOR STERIS DOSING SYSTEMS: MAX 12 FT OF INJECTION LINE FROM CONTAINERS TO DOSING STATION MAX

150 FT OF INJECTION LINE FROM DETERGENT CONTAINER TO TOP OF WASHER.*

9. DOSING SYSTEM POWERED BY THE WASHER.*

38" MINIMUM

WALL WIDTH

REQUIRED

FOR ACU-HOLD

38" MINIMUM

WALL WIDTH

REQUIRED

FOR ACU-HOLD

1 4

6"

BACKING

12"

BACKING

DOSING SYSTEM

SERVICE/OPERATIONAL

CLEARANCE

ACU-HOLD

CHEMICAL

CONTAINERS

16 GAUGE STRAP

BACKING REQUIRED

(NOT BY STERIS)

16 GAUGE STRAP

BACKING REQUIRED

(NOT BY STERIS)

38" MINIMUM

WALL WIDTH

REQUIRED

FOR ACU-HOLD

1 2

1 4

6"

BACKING

12"

BACKING

2634"76"

116"

23" 38" 7112"

2618"76"

116"

38" MINIMUM

WALL WIDTH

REQUIRED

FOR ACU-HOLD

38" MINIMUM

WALL WIDTH

REQUIRED

FOR ACU-HOLD

1 2

6"

BACKING

1 4

12"

BACKING

DETERGENT AND DOSING SYSTEMS DETAILS

Scale: 1/4" = 1' - 0"

PLAN WEST WALL

A

Scale: 1/4" = 1' - 0"

PLAN SOUTH WALL

B

Scale: 1/4" = 1' - 0"

PLAN EAST WALL

C

REVISION HISTORY

REVISION # DESCRIPTION PLANNER/DATE

UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH

ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021

Planning & Design Group

STERIS

5960 Heisley Road

Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.

Dr

Ck

Date

Scale

H- D

F.W.O. ELEVATIONS & DETERGENT DETAILS

STERILE PROCESSING DEPARTMENT

PROPOSED EQUIPMENT LAYOUT

HOUSTON VA MEDICAL CENTER

HOUSTON, TEXAS

1/4" = 1'-0"

28AUG2019

JZT

MK

8R5

S S

S S

S S

S S

S S

S S

S S

S S

S S

SS SS

101112

G

H

BB-285

SUPPLY

PROCESSING AND

DISTRIBUTION

BB-260A

EQ STORAGE &

TEST

BB-220B

EQ WASH

BB-261B

HAC

BB-220

DECONTAMINATION

BB-210

PREP/ASSEMBLY

BB-261

STERILE STORAGE

BB-260D

T-5 ROOM

S5505D

F0230

F0230

F0230 F0230

F0230F0230

F0230

F0230

F0230

F0230

A5075

A5080

A5075

A5080

A1014

A1014

BB-230C

ELEVATOR MACH.

F3200

F3200

A1014

A5077

A5077

A5077

A5077

A5077

M1825

M1825

M1825

M1825

M1825

M1825 M1825

M1825

M1825

M1825

FEC

FEC

S5505D S5505C S5505C S5505B S5505B S5505A

A5075

A5080

FEC

FEC

FEC

FEC

BB-220C

HAC

BB-231A

ANTE ROOM

M1801

A1195XE

A1195XE

A1195XE

A1195XE

S2635XE

M I N I M U M

P R E F E R R E

DS0235E

21E 22E 22E

21E 22E21E

22E 22E21E

22E21E 22E

33E

SEISMIC

SEISMIC

34E

A1195X

A1195X

S2635A

S0048

S0026X

S0940 S0020X

S0048

S0026X

S0048

S0940R

S0026X

S0940R S0940

S0048 S0048

S0026X

S0940R

S0048

S0004C

DECONTAM

S0020 S0006

S9610

S9610S9610

S9610S9610

S9610S9610 S9610

S9610S9610

FRONT

U0002

FRONT

U0002

S9815

S9815

S9815

S9815

S9815

S9815

S9815 15E

15E

15E

15E

15E

15E

15E15E

15E

15E

15E

15E

15E

15E

18E

18E 18E 18E 18E

18E

18E

18E18E

18E

18E

18E

18E

R E C O M M E N D E D

I N S T A L L A T I O N

C L E A R A N C E

R E C O M M E N D E D

I N S T A L L A T I O N

C L E A R A N C E

S3185

18E 18E 18E18E

18E 18E 18E

18E18E18E

18E 18E

F R O N

TU0002

F R O N

TU0002

18E18E

18E 18E

FRONT

U0002

EQUIPMENT LIST

TAG QTY DESCRIPTION

15E 14 Existing Amsco 600 Loading Car and Transfer Carriage - 26.5x26.5x63"/Fixed Height

18E 29 Existing STERIS Closed Case Cart - 27.5x36x54"/Single Door/Stainless Steel

21E 5 Existing Acu-Hold System - Wall Mounted/3 Container

22E 7 Existing STERIS Dosing System - 3 Pumps (Included with Washer/Power supplied by Washer)

30 1 InnoWave PRO Sonic Irrigator - 60 Lumen Capacity/200-230 Volt/3 Phase

32 2 InnoWave PCF Sonic Irrigator - 20 Lumen Capacity/200-230 Volt/3 Phase

33E 1 Existing Amsco 50 Reprocessing Sink - 3 Bay/97.5" Long/Height Adjustable

34E 1 Existing InnoWave Unity Ultrasonic Irrigator - 15 Gallon

A1195X 2 Existing Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)

A1195XE 4 Existing Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)

S0004C 1 Existing Amsco Drying Cabinet - 38"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)

S0006 1 Existing Amsco Drying Cabinet - 29"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)

S0020 1 Existing STERIS Automated Pass-Through Window - MDR/CSSD Application (28x45" Window)

S0020X 1 Existing SCS Motorized Return Conveyor System - 4 Module/Return Door/Flush Mounted

S0026X 4 Existing SCS Load/Unload Conveyor System - Single Load/Single Unload

S0048 6 Existing Reliance Transfer Cart

S0235E 1 Relocated Existing Amsco 400 Small Steam Sterilizer - 20x20x38" (508x508x965mm)(250L)/Single Door/Recessed/Steam Heat

S0940 2 Existing Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted

S0940R 3 Existing Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted/Reverse Install

S2635A 1 Existing InnoWave PRO Sonic Irrigator - 60 Lumen Capacity

S2635XE 1 Existing Caviwave Pro 17-DRW Ultrasonic Console - Dry/Rinse/Wash/17 Gallon/Right to Left Workflow

S3185 1 Existing Vision 1327 (Qty. 2) Side by Side Cart and Utensil Washer/Disinfectors - Shared Service/Double Door/Pit Mounted/Steam Heat/Common Service Area Junction Panels

S9610 10 Existing Amsco Deluxe Prep and Pack Workstation - 36x72"/Electric Height Adjustable

S9815 7 Existing Amsco 600 Medium Steam Sterilizer - 26.5x26.5x63" (673x673x1600mm)/Double Sliding Door/Recessed 2 Walls/Steam Heat

U0002 5 Existing Hanel Automated Rotomat Storage System - Model SSC117 (10'-0" Ceiling/5966 lbs Unloaded Weight/16466 lbs Loaded Weight)

REVISION HISTORY

REVISION # DESCRIPTION PLANNER/DATE

UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH

ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021

Planning & Design Group

STERIS

5960 Heisley Road

Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.

Dr

Ck

Date

Scale

H- D

PARTIAL FLOOR PLAN

STERILE PROCESSING DEPARTMENT

PROPOSED EQUIPMENT LAYOUT - FUTURE OPTION

HOUSTON VA MEDICAL CENTER

HOUSTON, TEXAS

3/16" = 1'-0"

28AUG2019

JZT

MK

8R5

Sheets and Views
2380D8R5-OPTION OPENING
2380D8R5-FS
2380D8R5-ELEVATIONS
2380D8R5-LAYOUT FUTURE

File details come from the government source that posted it. Updated .