2380D8R5 1 drawings.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25625Q0479
About this file
These are STERIS design drawings for the Sterile Processing Department equipment layout at the Houston VA Medical Center, depicting two equipment configuration options: an opening day option and a future option. The drawings include detailed floor plans, equipment lists, wall opening elevations, floor sink locations, and installation details for medical equipment such as washers/disinfectors, sterilizers, storage systems, and support infrastructure. The comprehensive set includes four pages of technical drawings specifying precise equipment placement, recommended clearances, and installation requirements for medical equipment in the VA facility's sterile processing area, with specific attention to equipment positioning, electrical and plumbing considerations, and workflow optimization.
The equipment list encompasses multiple STERIS and Amsco branded medical devices, including loading cars, case carts, dosing systems, reprocessing sinks, drying cabinets, pass-through windows, conveyor systems, transfer carts, sonic irrigators, ultrasonic cleaners, prep and pack workstations, steam sterilizers, and automated storage systems. The drawings are dated 28 August 2019, with a revision on 22 February 2021, and are designed for the Houston VA Medical Center located in Houston, Texas, with a scale of 3/16" = 1'-0" and drawn by STERIS Planning & Design Group.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFIS COMPLETED 3.docx | DOCX document | |
| AMENDED SCHEDULE.docx | DOCX document | |
| 36C25625Q0479 0004.docx | DOCX document | |
| AMENDMENT 36C25625Q0479 0003.docx | DOCX document | |
| RFIS COMPLETED 2.docx | DOCX document | |
| AMENDMENT 36C25625Q0479 0002.docx | DOCX document | |
| HST-100-0BAR.pdf | ||
| RO AND DI WATER SYSTEM - PRE-BID RFIs- COMPLETE.docx | DOCX document | |
| AMENDMENT 36C25625Q0479 0001.docx | DOCX document | |
| Service Contract Act WD 2015-5233.txt | TXT text file | |
| WAGE DETERMINATION - TX20250253 01-03-2025 - CONSTRUCTION.txt | TXT text file | |
| 36C25625Q0479 - SOLICITATION.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
S S
S S
S S
S S
S S
S S
S S
S S
S S
SS SS
101112
G
H
BB-285
SUPPLY
PROCESSING AND
DISTRIBUTION
BB-230D
FEMALE LOCKER
BB-230E
TOILET - FEMALE
BB-230
LOCKER
BB-260A
EQ STORAGE &
TEST
BB-220B
EQ WASH
BB-261B
HAC
BB-220
DECONTAMINATION
BB-210
PREP/ASSEMBLY
BB-261
STERILE STORAGE
BB-260D
T-5 ROOM
S5505D
F0230
F0230
F0230 F0230
F0230F0230
F0230
F0230
F0230
F0230
A5075
A5080
A5075
A5080
A1014
A1014
BB-230C
ELEVATOR MACH.
F3200
F3200
A1014
A5077
A5077
A5077
A5077
A5077
M1825
M1825
M1825
M1825
M1825
M1825 M1825
M1825
M1825
M1825
FEC
FEC
S5505D S5505C S5505C S5505B S5505B S5505A
A5075
A5080
FEC
FEC
FEC
FEC
BB-220C
HAC
BB-231A
ANTE ROOM
M1801
A1195XE
A1195XE
S2635E
S2635E
S2635E
A1195XE
A1195XE
FRONT
U0002
F R O N
TU0002
1818181818
1818181818
1818181818
F R O N
TU0002
S9610S9610
S9610 S9610
S9610S9610
S9610 S9610
S9610
S9610
S2635XE
M I N I M U M
P R E F E R R E
DS0235E
S9815
S9815
S9815
S9815
S9815
S9815
S9815
R E C O M M E N D E D
I N S T A L L A T I O N
C L E A R A N C E
R E C O M M E N D E D
I N S T A L L A T I O N
C L E A R A N C E
S3185
A1195X
A1195X
SEISMIC
SEISMIC
S2635A
S0006 S0004C
DECONTAM
S0020 S0026X
S0048
S0026X
S0048
S0020X
S0026X S0026X S0026X
S0048 S0048
S0048 S0048
S0940 S0940
S0940RS0940RS0940R
1818181818
1818181818
MOVED WALL PLAN
EAST 38" TO FIT
EQUIPMENT
MODIFIED WALL AND SHIFT WASHERS
PLAN WEST 3"
FRONT
U0002
FRONT
U0002
FOR EACH WASHER/CART WASHER, A 3" I.D. CONDUIT REQUIRED FROM DETERGENT
PUMP LOCATION(S) TO WASHER LOCATION(S) - NOT PROVIDED BY STERIS
EQUIPMENT LIST
TAG QTY DESCRIPTION
15 14 Amsco 600 Loading Car and Transfer Carriage - 26.5x26.5x63"/Fixed Height
18 29 STERIS Closed Case Cart - 27.5x36x54"/Single Door/Stainless Steel
21 5 Acu-Hold System - Wall Mounted/3 Container
22 7 STERIS Dosing System - 3 Pumps (Included with Washer/Power supplied by Washer)
33 1 Amsco 50 Reprocessing Sink - 3 Bay/97.5" Long/Height Adjustable
34 1 InnoWave Unity Ultrasonic Irrigator - 15 Gallon
A1195X 2 Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)
A1195XE 4 Existing Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)
S0004C 1 Amsco Drying Cabinet - 38"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)
S0006 1 Amsco Drying Cabinet - 29"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)
S0020 1 STERIS Automated Pass-Through Window - MDR/CSSD Application (28x45" Window)
S0020X 1 SCS Motorized Return Conveyor System - 4 Module/Return Door/Flush Mounted
S0026X 5 SCS Load/Unload Conveyor System - Single Load/Single Unload
S0048 6 Reliance Transfer Cart
S0235E 1 Relocated Existing Amsco 400 Small Steam Sterilizer - 20x20x38" (508x508x965mm)(250L)/Single Door/Recessed/Steam Heat
S0940 2 Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted
S0940R 3 Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted/Reverse Install
S2635A 1 InnoWave PRO Sonic Irrigator - 60 Lumen Capacity
S2635E 3 Existing Caviwave 20-W Ultrasonic Cleaner - Wash/20 Gallon
S2635XE 1 Existing Caviwave Pro 17-DRW Ultrasonic Console - Dry/Rinse/Wash/17 Gallon/Right to Left Workflow
S3185 1 Vision 1327 (Qty. 2) Side by Side Cart and Utensil Washer/Disinfectors - Shared Service/Double Door/Pit Mounted/Steam Heat/Common Service Area Junction Panels
S9610 10 Amsco Deluxe Prep and Pack Workstation - 36x72"/Electric Height Adjustable
S9815 7 Amsco 600 Medium Steam Sterilizer - 26.5x26.5x63" (673x673x1600mm)/Double Sliding Door/Recessed 2 Walls/Steam Heat
U0002 5 Hanel Automated Rotomat Storage System - Model SSC117 (10'-0" Ceiling/5966 lbs Unloaded Weight/16466 lbs Loaded Weight)
REVISION HISTORY
REVISION # DESCRIPTION PLANNER/DATE
UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH
ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021
Planning & Design Group
STERIS
5960 Heisley Road
Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.* THE WALLS AND OR EQUIPMENT SHOWN IN THIS DRAWING HAVE BEEN MOVED/MODIFIED TO ACCOMMODATE MINIMUM RECOMMENDED CLEARANCES FOR STERIS EQUIPMENT
Dr
Ck
Date
Scale
H- D
PARTIAL FLOOR PLAN
STERILE PROCESSING DEPARTMENT
PROPOSED EQUIPMENT LAYOUT - OPENING DAY OPTION
HOUSTON VA MEDICAL CENTER
HOUSTON, TEXAS
3/16" = 1'-0"
28AUG2019
JZT
MK
8R5
S S
S S
S S
S S
S S
S S
S S
S S
S S
SS SS
101112
G
H
J
BB-285
SUPPLY
PROCESSING AND
DISTRIBUTION
BB-220B
EQ WASH
BB-261B
HAC
BB-220
DECONTAMINATION
BB-210
PREP/ASSEMBLY
BB-261
STERILE STORAGE
BB-260D
T-5 ROOM
BB-230C
ELEVATOR MACH.
BB-220C
HAC
BB-231A
ANTE ROOM
20314"
97 8
71 2"
20618"
11 8
93 8
18834"
19114"
93 8
93 8
93 8
93 8
93 8
95 8
51 2"
81 2" WASHER FLOOR
SINK- TYP.3
7212" 7834" 7234" 1958" 6758"
WASHER FLOOR
SINK- TYP.2
EXISTING SONIC
FLOOR SINK
TYP.4
RELOCATED
EXISTING
STERILIZER
FLOOR SINK
STERILIZER
FLOOR SINK
TYP.7
SEE PIT
DETAILS FOR
FLOOR SINK
LOCATIONS
SINK STATION
FLOOR SINK
TYP.2
EXISTING SINK
STATION FLOOR
SINK TYP.4
SONIC
FLOOR
SINK
SONIC
FLOOR
SINK
SINK STATION
FLOOR SINK
12738"
90"130"
41 2"
95 8
41 2"
87 8"
1 4
1878" 1178"
7718" 10934" 5458"
9778" 5078"
3734"
21" Scale: 3/16" = 1' - 0"
SECTION VIEW - 1327 PIT DETAILS
2x2x 3
16" STAINLESS
STEEL ANGLE AROUND
PERIMETER OF PIT
(SEE NOTES 1 AND 2)
FINISHED
FLOOR
RECOMMENDED 8" MIN. (ROUND OR SQUARE) x 6" DEEP
FLOOR SINK WITH 4" O.D. DRAIN OUTLET; DRAIN SHALL
FURNISH FOR 60 U.S. GPM FLOW (SEE NOTES 1 AND 3)
6" MIN. (634" MAX.)
FINISHED FLOOR
TO TOP OF PAD
(TYP. OF 4)
(SEE NOTE 1)
634"
PIT DEPTH
PIT DETAIL NOTES:
1. ALL MATERIAL (INCLUDING CONCRETE, CORNER LEVELING PADS, STAINLESS
STEEL ANGLES, FLOOR SINK) AND LABOR FOR CONSTRUCTION OF PIT TO BE BY
OTHERS THAN STERIS
2. STAINLESS STEEL ANGLES ARE RECOMMENDED BY STERIS; TO BE SUPPLIED AND
INSTALLED BY OTHERS THAN STERIS
3. SLOPE PIT TO DRAIN (1 DEGREE)
CORNER LEVELING PAD
(TYP. OF 4 - SEE NOTE 1)
REVISION HISTORY
REVISION # DESCRIPTION PLANNER/DATE
UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH
ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021
14614" 118"
15 8
22"
412"
22" 412"
1 4
12"
16"
1 4
PIT
FLOOR SINK
12"
1 4"
16"16"
12"
16"
12"
SCALE: 3/16" = 1'-0"
FLOOR SINK LOCATIONS PLAN
SCALE: 3/16" = 1'-0"
PIT DIMENSIONS
Planning & Design Group
STERIS
5960 Heisley Road
Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.
Dr
Ck
Date
Scale
H- D
FLOOR SINKS LOCATION PLAN & PIT DETAILS
STERILE PROCESSING DEPARTMENT
PROPOSED EQUIPMENT LAYOUT - OPENING DAY OPTION
HOUSTON VA MEDICAL CENTER
HOUSTON, TEXAS
3/16" = 1'-0"
28AUG2019
JZT
MK
8R5
1534"4214"4214"87"2458" 30" 2058" 19" 39"
53458"
S0006 S0020
S0004C
S0020X11
S0940 S0940R
Scale: 1/4" = 1' - 0"
FINISHED WALL OPENING ELEVATION - WASHER BARRIER WALL LOAD SIDE
S0940RS0940R
S0940
87" 45"
M I N
R E C O M M E N D E D
T Y P
V E R I F Y
C E I L I N G
H E I G H T
M I N
R E C O M M E N D E D
C E I L I N G
H E I G H T
F O R
D O O R
R E M O V A L
T Y P
12" STRAP BACKING
REQUIRED ON LOAD
AND UNLOAD SIDES
UNDER WALL OPENING
FOR COUNTER SUPPORT
1 4
V E R I F Y
12"
2814" 3178"
S E R V I C E
C L E A R A N C E
A B O V E
F I N I S H E D
F L O O R
T Y P
S
S C
M I N
C E I L I N G
H E I G H T
85 8
T Y P
S
S C
1018" 1178"
35458"
217" 1058" 217" 1058"
S3185
Scale: 1/4" = 1' - 0"
FINISHED WALL OPENING ELEVATION - CART WASHERS UNLOAD SIDE
Scale: 1/4" = 1' - 0"
FINISHED WALL OPENING ELEVATION - CART WASHERS LOAD SIDE
S3185
V E R I F Y
C E I L I N G
H E I G H T
R E C O M M E N D E D
S E R V I C E
C L E A R A N C E
A B O V E
F I N I S H E D
F L O O R
93 4
M I N
R E C O M M E N D E D
S E R V I C E
C L E A R A N C E
A B O V E
F I N I S H E D
F L O O R
93 4
M I N
V E R I F Y
C E I L I N G
H E I G H T
1 4
S0235E
Scale: 1/4" = 1' - 0"
FINISHED WALL OPENING ELEVATION - STERILIZERS LOAD SIDE
Scale: 1/4" = 1' - 0"
FINISHED WALL OPENING ELEVATION - STERILIZERS UNLOAD SIDE
27714"
91 8"
S E R V I C E
C L E A R A N C E
V E R I F Y
C E I L I N G
H E I G H T
01 2"
S9815 S9815 S9815 S9815 S9815 S9815 S9815
5078" 2818" 1278"
S9815 S9815 S9815 S9815 S9815 S9815 S9815
9178" 27714"
91 8"
S E R V I C E
C L E A R A N C E
V E R I F Y
C E I L I N G
H E I G H T
01 2"
SHEET NOTES :
1. AMBIENT TEMPERATURE SHALL NOT EXCEED 104°F.
2. DETERGENT AND SIGNAL LINES NOT TO COME INTO CONTACT WITH HOT SURFACES.
3. EXCESS LENGTH MUST BE CUT BEFORE CONNECTING TO WASHER/STATION TO AVOID FORMING BUNDLES THAT
COULD AFFECT THE DETERGENT INJECTION SYSTEM'S PERFORMANCES.
4. 3"I.D. CONDUIT REQUIRED FROM PUMP LOCATION(S) TO WASHER LOCATION(S)- NOT PROVIDED BY STERIS.
5. ALL 90 DEGREE CONDUIT TURNS MUST USE SWEEPING 90 DEGREE CONNECTIONS. STRAIGHT 90 DEGREE
CONNECTIONS ARE NOT RECOMMENDED.
6. FINAL LOCATION OF RUNS TO BE COORDINATED WITH ARCHITECT, CONTRACTORS, AND STERIS INSTALLATION
PERSONNEL.
7. A MAXIMUM OF TWO WASHERS OR ONE CART WASHER CAN SHARE CHEMICAL CONTAINERS. DEDICATED CONTAINERS
RECOMMENDED FOR EACH WASHER.
8. FOR STERIS DOSING SYSTEMS: MAX 12 FT OF INJECTION LINE FROM CONTAINERS TO DOSING STATION MAX
150 FT OF INJECTION LINE FROM DETERGENT CONTAINER TO TOP OF WASHER.*
9. DOSING SYSTEM POWERED BY THE WASHER.*
38" MINIMUM
WALL WIDTH
REQUIRED
FOR ACU-HOLD
38" MINIMUM
WALL WIDTH
REQUIRED
FOR ACU-HOLD
1 4
6"
BACKING
12"
BACKING
DOSING SYSTEM
SERVICE/OPERATIONAL
CLEARANCE
ACU-HOLD
CHEMICAL
CONTAINERS
16 GAUGE STRAP
BACKING REQUIRED
(NOT BY STERIS)
16 GAUGE STRAP
BACKING REQUIRED
(NOT BY STERIS)
38" MINIMUM
WALL WIDTH
REQUIRED
FOR ACU-HOLD
1 2
1 4
6"
BACKING
12"
BACKING
2634"76"
116"
23" 38" 7112"
2618"76"
116"
38" MINIMUM
WALL WIDTH
REQUIRED
FOR ACU-HOLD
38" MINIMUM
WALL WIDTH
REQUIRED
FOR ACU-HOLD
1 2
6"
BACKING
1 4
12"
BACKING
DETERGENT AND DOSING SYSTEMS DETAILS
Scale: 1/4" = 1' - 0"
PLAN WEST WALL
A
Scale: 1/4" = 1' - 0"
PLAN SOUTH WALL
B
Scale: 1/4" = 1' - 0"
PLAN EAST WALL
C
REVISION HISTORY
REVISION # DESCRIPTION PLANNER/DATE
UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH
ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021
Planning & Design Group
STERIS
5960 Heisley Road
Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.
Dr
Ck
Date
Scale
H- D
F.W.O. ELEVATIONS & DETERGENT DETAILS
STERILE PROCESSING DEPARTMENT
PROPOSED EQUIPMENT LAYOUT
HOUSTON VA MEDICAL CENTER
HOUSTON, TEXAS
1/4" = 1'-0"
28AUG2019
JZT
MK
8R5
S S
S S
S S
S S
S S
S S
S S
S S
S S
SS SS
101112
G
H
BB-285
SUPPLY
PROCESSING AND
DISTRIBUTION
BB-260A
EQ STORAGE &
TEST
BB-220B
EQ WASH
BB-261B
HAC
BB-220
DECONTAMINATION
BB-210
PREP/ASSEMBLY
BB-261
STERILE STORAGE
BB-260D
T-5 ROOM
S5505D
F0230
F0230
F0230 F0230
F0230F0230
F0230
F0230
F0230
F0230
A5075
A5080
A5075
A5080
A1014
A1014
BB-230C
ELEVATOR MACH.
F3200
F3200
A1014
A5077
A5077
A5077
A5077
A5077
M1825
M1825
M1825
M1825
M1825
M1825 M1825
M1825
M1825
M1825
FEC
FEC
S5505D S5505C S5505C S5505B S5505B S5505A
A5075
A5080
FEC
FEC
FEC
FEC
BB-220C
HAC
BB-231A
ANTE ROOM
M1801
A1195XE
A1195XE
A1195XE
A1195XE
S2635XE
M I N I M U M
P R E F E R R E
DS0235E
21E 22E 22E
21E 22E21E
22E 22E21E
22E21E 22E
33E
SEISMIC
SEISMIC
34E
A1195X
A1195X
S2635A
S0048
S0026X
S0940 S0020X
S0048
S0026X
S0048
S0940R
S0026X
S0940R S0940
S0048 S0048
S0026X
S0940R
S0048
S0004C
DECONTAM
S0020 S0006
S9610
S9610S9610
S9610S9610
S9610S9610 S9610
S9610S9610
FRONT
U0002
FRONT
U0002
S9815
S9815
S9815
S9815
S9815
S9815
S9815 15E
15E
15E
15E
15E
15E
15E15E
15E
15E
15E
15E
15E
15E
18E
18E 18E 18E 18E
18E
18E
18E18E
18E
18E
18E
18E
R E C O M M E N D E D
I N S T A L L A T I O N
C L E A R A N C E
R E C O M M E N D E D
I N S T A L L A T I O N
C L E A R A N C E
S3185
18E 18E 18E18E
18E 18E 18E
18E18E18E
18E 18E
F R O N
TU0002
F R O N
TU0002
18E18E
18E 18E
FRONT
U0002
EQUIPMENT LIST
TAG QTY DESCRIPTION
15E 14 Existing Amsco 600 Loading Car and Transfer Carriage - 26.5x26.5x63"/Fixed Height
18E 29 Existing STERIS Closed Case Cart - 27.5x36x54"/Single Door/Stainless Steel
21E 5 Existing Acu-Hold System - Wall Mounted/3 Container
22E 7 Existing STERIS Dosing System - 3 Pumps (Included with Washer/Power supplied by Washer)
30 1 InnoWave PRO Sonic Irrigator - 60 Lumen Capacity/200-230 Volt/3 Phase
32 2 InnoWave PCF Sonic Irrigator - 20 Lumen Capacity/200-230 Volt/3 Phase
33E 1 Existing Amsco 50 Reprocessing Sink - 3 Bay/97.5" Long/Height Adjustable
34E 1 Existing InnoWave Unity Ultrasonic Irrigator - 15 Gallon
A1195X 2 Existing Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)
A1195XE 4 Existing Amsco 50 Reprocessing Sink - 3 Bay/120" Long/Height Adjustable (Delivery may be restricted by hallway width. STERIS installation and delivery teams to verify prior to shipping.)
S0004C 1 Existing Amsco Drying Cabinet - 38"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)
S0006 1 Existing Amsco Drying Cabinet - 29"/Double Door/Pass-Thru (110-120 Volt/20 Amp Dedicated Wall Plug)
S0020 1 Existing STERIS Automated Pass-Through Window - MDR/CSSD Application (28x45" Window)
S0020X 1 Existing SCS Motorized Return Conveyor System - 4 Module/Return Door/Flush Mounted
S0026X 4 Existing SCS Load/Unload Conveyor System - Single Load/Single Unload
S0048 6 Existing Reliance Transfer Cart
S0235E 1 Relocated Existing Amsco 400 Small Steam Sterilizer - 20x20x38" (508x508x965mm)(250L)/Single Door/Recessed/Steam Heat
S0940 2 Existing Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted
S0940R 3 Existing Amsco 7052HP Single-Chamber Washer/Disinfector - Double Door/Steam Heat/Non-Vented/Flush Mounted/Reverse Install
S2635A 1 Existing InnoWave PRO Sonic Irrigator - 60 Lumen Capacity
S2635XE 1 Existing Caviwave Pro 17-DRW Ultrasonic Console - Dry/Rinse/Wash/17 Gallon/Right to Left Workflow
S3185 1 Existing Vision 1327 (Qty. 2) Side by Side Cart and Utensil Washer/Disinfectors - Shared Service/Double Door/Pit Mounted/Steam Heat/Common Service Area Junction Panels
S9610 10 Existing Amsco Deluxe Prep and Pack Workstation - 36x72"/Electric Height Adjustable
S9815 7 Existing Amsco 600 Medium Steam Sterilizer - 26.5x26.5x63" (673x673x1600mm)/Double Sliding Door/Recessed 2 Walls/Steam Heat
U0002 5 Existing Hanel Automated Rotomat Storage System - Model SSC117 (10'-0" Ceiling/5966 lbs Unloaded Weight/16466 lbs Loaded Weight)
REVISION HISTORY
REVISION # DESCRIPTION PLANNER/DATE
UPDATED CAD BACKGROUND; UPDATED EQUIPMENT TAG TO MATCH
ARCHITECTS TAG NUMBERS; UPDATED DETAIL SHEETS JZT/22FEB2021
Planning & Design Group
STERIS
5960 Heisley Road
Mentor, OH 44060 USA 800-548-4873STERIS drawings do not supersede the drawings from the architect of record.
Dr
Ck
Date
Scale
H- D
PARTIAL FLOOR PLAN
STERILE PROCESSING DEPARTMENT
PROPOSED EQUIPMENT LAYOUT - FUTURE OPTION
HOUSTON VA MEDICAL CENTER
HOUSTON, TEXAS
3/16" = 1'-0"
28AUG2019
JZT
MK
8R5
| Sheets and Views |
| 2380D8R5-OPTION OPENING |
| 2380D8R5-FS |
| 2380D8R5-ELEVATIONS |
| 2380D8R5-LAYOUT FUTURE |
File details come from the government source that posted it. Updated .