This document appears to be a set of architectural drawings for a Security Training Dormitory building (Building 190) located in North Little Rock, Arkansas. The drawings provide detailed specifications and plans for the building's exterior elevations, cross-sections, and floor plans, including the structural components, roofing materials, and exterior finishes.
The related federal contract opportunity is for the roof renovations of Buildings 190 and 191 at the VA LETC (Law Enforcement Training Center) in North Little Rock, Arkansas, under Project 598-23-140. The solicitation number is 36C25624R0073, with a site visit scheduled for 3-7-2024 and proposal submissions due by 3-27-2024, unless changed by amendment. The Department of Veterans Affairs, Veterans Health Administration, and Veterans Integrated Service Network 16 are the federal agencies involved in this contract opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 598-23-140 Site Visit 2 sign in 031824.pdf | ||
| 200086-EJ3.pdf | ||
| LETCA6.pdf | ||
| 598-23140 - SITE VISIT 1 SIGN IN.pdf | ||
| A501 old wing.pdf | ||
| 36C25624R0073 0002_1.docx | DOCX document | |
| 174REJ7.pdf | ||
| 598-23-140 - PRE-BID RFIs COMPLETE.docx | DOCX document | |
| 2886a201.pdf | ||
| A201 old wing.pdf | ||
| A202 old wing.pdf | ||
| A501.pdf | ||
| 2886a501.pdf | ||
| 36C25624R0073 0002.docx | DOCX document | |
| 36C25624R0073 0001.docx | DOCX document | |
| 36C25624R0073 0001_1.docx | DOCX document | |
| VA LR AND NLR INSPECTION REPORT AND OHM TEST RESULTS 2019.pdf | ||
| SOW B190 191 Roof Renovations.pdf | ||
| 36C25624R0073 - SOLICITATION.docx | DOCX document | |
| CONTRACTOR EVALUATION FORM.docx | DOCX document | |
| WAGE DETERMINATION AR20240032 01-05-2024.pdf | ||
| 36C25624R0073_1.docx | DOCX document | |
| Past and Present Performance Questionnaire.docx | DOCX document |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
First Floor 516' - 4"
Second Floor 525' - 8"
A1 A302
Third Floor 535' - 0"
Attic 544' - 4"
L1 A201 step flashing new cricket existing roof split faced CMU exist. corridor
A602 A4 sim.
brick sill cjcj soldier course around window punch parapet wall asphalt shingles asphalt shingles
EIFS panel
EIFS final coat on concrete exterior light fixture grade
EIFS column cover
First Floor 516' - 4"
Second Floor 525' - 8"
A1 A302
Third Floor 535' - 0"
Attic 544' - 4"
L1 A201 new cricket existing roof step flashing existing masonry wall exist. corridor
A602 A4 asphalt shingles punch parapet wall asphalt shingles
EIFS panel
EIFS final coat on concrete cj cj brick sill soldier course around window dryer vents
EIFS column cover grade
EIFS panel
First Floor 516' - 4"
Second Floor 525' - 8"
VI 1.11.2
Third Floor 535' - 0"
Attic 544' - 4" removable louver new cricket step flashing line of existing ceiling metal coping cjcj existing buildingexisting building
First Floor 516' - 4"
Second Floor 525' - 8"
VI1.1 1.2
Third Floor 535' - 0"
Attic 544' - 4" step flashing metal fascia EIFS panel metal coping asphalt shingle
EIFS column cover brick split face cmu cjcj
EIFS column cover
EIFS final coat on concrete
First Floor 516' - 4"
Second Floor 525' - 8"
VI1.1 1.2
Third Floor 535' - 0"
Attic 544' - 4"
L7 A201
A602 A16
A17 A603
Wood Trusses
Dorm
Dorm
Dorm
Dorm
Dorm
Dorm
Corr.
Corr.
Corr.
First Floor 516' - 4"
Second Floor 525' - 8"
T.O. Footing 514' - 0"
A1 A302
Third Floor 535' - 0"
Attic 544' - 4"
L1 A201
1 hour partition around stair existing roof new cricket A603 L17
A603 A17
Wood Trusses
Corridor
Corridor
Corridor
Sun Rm.
Sun Rm.
Sun Rm.
NO. C-6
ARCHITECTS
REGISTERED
S U
C T
A R K NA S
S
S
K A
AI
OC
T E S
T
S
SA
T C
E
R
I H
C
A
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
REVISIONS DATE
APPROVED: Medical Center Director
APPROVED: Associate Director
APPROVED: Assistant Director
APPROVED: Chief of Staff
APPROVED: Facility Planner
APPROVED: Chief Engineer
APPROVED: Service Chief
APPROVED: Service Chief
APPROVED: Service Chief
DRAWING TITLE
ARCHITECTS
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
LOCATION
DATE
PROJECT NUMBER
DRAWING NO.
Dwg. of 47
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
A
FF
AI
R
S
Offic e o f F ac iliti es
8/
/2
:1 2:
A
M
North Little Rock, AR
8-1-08
2.3597.08
Security Training Dormitory
A201
MD RC GC KW
Building Elevations
1/8" = 1'-0" G1 East Elevation
1/8" = 1'-0" A1 West Elevation
1/8" = 1'-0" A13 North Elevation from Existing Corridor
1/8" = 1'-0" G13 South Elevation
1/8" = 1'-0" L1 Cross Section
1/8" = 1'-0" L7 Longitudinal Section
| Sheets and Views |
| A201-Layout1 |
File details come from the government source that posted it. Updated .