This document appears to be architectural drawings and details related to a roof renovation project for buildings 190 and 191 at the VA Law Enforcement Training Center (LETC) in North Little Rock, Arkansas. The project is solicitation number 36C25624R0073, titled "Z1AA--598-23-140 | CON | B190/191 Roof Renovations LETC".
The drawings provide detailed specifications for the roof replacement, including the installation of new asphalt shingles, plywood decking, ridge vents, flashing, and other roofing components. The specifications also include requirements for insulation, brick masonry, and other structural elements. A site visit is scheduled for 3-7-2024, and requests for information are due by 3-12-2024. Proposals for this project are due on 3-27-2024, unless changed by amendment. The contracting agency is the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 16.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 598-23-140 Site Visit 2 sign in 031824.pdf | ||
| 200086-EJ3.pdf | ||
| LETCA6.pdf | ||
| 598-23140 - SITE VISIT 1 SIGN IN.pdf | ||
| A501 old wing.pdf | ||
| 36C25624R0073 0002_1.docx | DOCX document | |
| 174REJ7.pdf | ||
| 598-23-140 - PRE-BID RFIs COMPLETE.docx | DOCX document | |
| 2886a201.pdf | ||
| A201 old wing.pdf | ||
| A202 old wing.pdf | ||
| A501.pdf | ||
| 36C25624R0073 0002.docx | DOCX document | |
| A201.pdf | ||
| 36C25624R0073 0001.docx | DOCX document | |
| 36C25624R0073 0001_1.docx | DOCX document | |
| VA LR AND NLR INSPECTION REPORT AND OHM TEST RESULTS 2019.pdf | ||
| SOW B190 191 Roof Renovations.pdf | ||
| 36C25624R0073 - SOLICITATION.docx | DOCX document | |
| CONTRACTOR EVALUATION FORM.docx | DOCX document | |
| WAGE DETERMINATION AR20240032 01-05-2024.pdf | ||
| 36C25624R0073_1.docx | DOCX document | |
| Past and Present Performance Questionnaire.docx | DOCX document |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8" M
IN
2"
VENT PIPE
TOP FLASHING
BASE FLASHING
COLLAR
ASPHALT
SHINGLES
PLYWOOD
AIR SPACE
IN DECK
ASPHALT
SHINGLES
4"
PLYWOOD
CONTINIOUS
RIDGE VENT
VALLEY
ROOFING FELT
EXTEND 18"
EACH SIDE
ASPHALT
SHINGLE
PLYWOOD
EXISTING FACE BRICK
WALL
SAW CUT MASONRY TO
RECIEVE REGLET
FLANGE
FRY MA SPRINGLOK
REGLET
ASPHALT
SHINGLES
PLYWOOD
8"
8" MIN.
8' -0
3'
-4
SUSP. AT.
GYP. BD. ON
MTL. STUD
FACE BRICK
CMU
EXISTING
WALL
EXISTING
CEILING
PAINTED GYP. BD.
ON METAL STUDS
2- LAYERS FIRE
CODE "X" GYP. BD.
NEW FACE
BRICK
CMU
PAINT TO
MATCH BRICK
FIRE STOPPING
RUBBER BASE
4'-0" 6" 4'-8"
LINE OF EXISTING BLDG.
DOUBLE EGRESS
DOOR FRAME
RIGID INSULATION
FACE BRICK WITH WALL
REINF. AT 16" CONCRETE
MASONRY UNIT
ASPHALT
SHINGLES
PLYWOOD
8"8" MIN. 8"
SAW CUT MASONRY TO
RECIEVE REGLET
FLANGE
FRY MA SPRINGLOK
REGLET
8"
FACE BRICK WITH WALL
REINF. AT 16"
FACE BRICK WITH
REINF. AT 16"
RIGID INSULATION
METAL FLASHING
8"
8" 6"
SAW CUT MASONRY TO
RECIEVE REGLET
FLANGE
FRY MA SPRINGLOK
REGLET
METAL
COPING
CONCRETE
MASONRY
UNIT
RIGID INSULATION
WALL REINFORCING:
AT 16" O.C.
8" 8"
'-0
6"
VCT ON 2- LAYERS OF
1/2" PLYWOOD
GLUED AND SCREWED
TO JOIST
2 X WOOD EDGE
2 x JOIST ON 16"
O.C.(TYP.)
RUBBER STAIR TREAD
RUBBER STAIR RISER
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
RIDGE
SLOPESLOPE
R
ID
G E
VALL
EY VALLEY
RIDGE VENT, SEE DETAIL P4/A501, TYPICAL
SEE VALLEY FLASHING DETAIL,
P8/A501, TYPICAL
BUILDING LINE BELOW
ASHPALT SHINGLE ROOFING
OVER 30 # FELT
3/4" PLYWOOD DECK, TYPICAL
VENT THRU ROOF
SEE DETAIL P1/A501
ASHPALT SHINGLE ROOFING
OVER 30 # FELT
3/4" PLYWOOD DECK, TYPICAL
A8 A501
P16 A501
P12 A501
RIDGE
SL
O
PE
SL
O
PE
RIDGE
3/4"=1'-0" A501
1 1/2"=1'-0" A501
1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REPORT ANY
DISCREPANCIES.
2. UNLESS OTHERWISE NOTED, ANY NOTE, DETAIL, OR FEATURE, INDICATED FOR
ONE CONDITION SHALL BE APPLICABLE FOR ALL ALIKE AND SIMILAR CONDITIONS.
3. THE APPROXIMATE LOCATION OF ROOF DEVICES AND PENETRATIONS ARE
SHOWN ON THE PLANS FOR INFORMATION ONLY. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR UNDERSTANDING THE ACTUAL LOCATION OF THESE AND ALL
OTHER ITEMS PRIOR TO BEGINNING CONSTRUCTION.
4. DO NOT APPLY ROOFING SYSTEM TO WET, DAMP, OR FROZEN DECK.
1 1/2"=1'-0" A501 1 1/2"=1'-0" A501 1 1/2"=1'-0" A501
3/32"=1'-0" A501
1 1/2"=1'-0" A501 1 1/2"=1'-0" A501 1 1/2"=1'-0" A501
1 1/2"=1'-0" A501
STUCK ASSOCIATES ARCHITECTS
LAW ENFORCEMENT TRAINING
CENTER ADDITION
AutoCAD SHX Text A1
AutoCAD SHX Text
SECTION @ EXISTING BUILDING
AutoCAD SHX Text P1
AutoCAD SHX Text
PIPE FLASHING
AutoCAD SHX Text A501
AutoCAD SHX Text
ROOF PLAN & DETAILS
AutoCAD SHX Text
ROOF NOTES
AutoCAD SHX Text P4
AutoCAD SHX Text
RIDGE VENT
AutoCAD SHX Text P8
AutoCAD SHX Text
VALLEY FLASHING
AutoCAD SHX Text P12
AutoCAD SHX Text
FLASHING DETAIL
AutoCAD SHX Text G8
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text A8
AutoCAD SHX Text
FLASHING DETAIL
AutoCAD SHX Text A12
AutoCAD SHX Text
COPING DETAIL
AutoCAD SHX Text A16
AutoCAD SHX Text
PLATFORM DETAIL
AutoCAD SHX Text P16
AutoCAD SHX Text
FLASHING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
30 MARCH 2001
AutoCAD SHX Text
V.A.M.C. LR DIVISION
AutoCAD SHX Text
AutoCAD SHX Text
LB
AutoCAD SHX Text
GRC
AutoCAD SHX Text
APPROVED: SERVICE CHIEF
AutoCAD SHX Text
APPROVED: SERVICE CHIEF
AutoCAD SHX Text
APPROVED: SERVICE CHIEF
AutoCAD SHX Text
APPROVED: CHIEF ENGINEER
AutoCAD SHX Text Office of Facilities
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
VETERANS AFFAIRS
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text Dwg of
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED: MEDICAL CENTER DIRECTOR
AutoCAD SHX Text
APPROVED: ASSOCIATE DIRECTOR
AutoCAD SHX Text
APPROVED: ASSISTANT DIRECTOR
AutoCAD SHX Text
APPROVED: FACILITY PLANNER
AutoCAD SHX Text
APPROVED: CHIEF OF STAFF
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text Q
AutoCAD SHX Text R
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text 2-2886-00
| Sheets and Views |
| 2886a501-DETAILS |
File details come from the government source that posted it. Updated .