CS-202A - ALTERNATE ADD IF CATE TERRACE DEDUCT IS ACCEPTED (Addendum 1).pdf

PDF 884 KB Posted

Attached to
Y1LB--580-16-102 Road Repairs on VA Campus
Solicitation number
36C25623R0048
Issued by

About this file

This pre-solicitation notice is for road repairs on a VA medical center campus. The Michael E. DeBakey VA Medical Center in Houston, Texas requires road repairs and alterations through a firm-fixed price construction contract valued between $2-5 million. The work includes general construction, civil, drainage, mechanical, electrical and utility relocation according to provided drawings and specifications. The period of performance is 180 days from notice to proceed. The solicitation will be issued as a request for proposals on or around February 1, 2023 electronically. This is a 100% service-disabled veteran-owned small business set-aside requiring at least 25% of labor costs to be spent on SDVOSB employees. Offerors must register on websites including Vendor Information Pages and SAM and complete representations and certifications by the proposal due date. The NAICS code is 237310 with a $45 million small business size standard.

View the file

Other files

File Type Posted
GEO REPORT - VA Campus.pdf PDF
36C25623R0048 0001.docx DOCX document
Clarifications.pdf PDF
Combined Underground Utilities Drawings.pdf PDF
Price Sheet 4-4-2023.docx DOCX document
321216 - Asphalt Paving.pdf PDF
CS-100 - OVERALL LAYOUT-(Addendum 1) 4-4-2023.pdf PDF
CampusMap_August2021.pdf PDF
580-16-102 Project Specifications.pdf PDF
SF24 Bid Bond.pdf PDF
580-16-102 Project Drawings Part I.pdf PDF
Price Breakdown.docx DOCX document
580-16-102 Statement of Work.docx DOCX document
580-16-102 Project Drawings Part II.pdf PDF
Solicitation 36C25623R0048.docx DOCX document
DOL Wage Determinations TX20230038 dated 1-6-23.pdf PDF
36C25623R0048.docx DOCX document
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PT

# 1

"C " C

UR

B

IN

LE

T

W

AT

ER

M

ET

ER

PT

# 1

S

TO

RM

M

H

DO

UB

LE

P

OS

T

SI

GN

PT

# 1

S

TO

RM

M

H

SI

GN

: S

TO

P

BO

LL

AR

DS

(2

BO

LL

AR

DS

(2

BO

LL

AR

DS

(2

BO

LL

AR

DS

(2

SI

GN

: S

TO

P

W

AT

ER

M

ET

ER FD

C

EL

EC

. M

ET

ER

5' CONCRETE WALK

EL

EC

. G

AT

E

MO

TO

R

6' W

RO

UG

HT

IR

ON

F

EN

CE

EL

EC

. M

ET

ER

PT

# 1

S

TO

RM

M H

CC

TV

O N

PO

LE

PT

# 1

S

AN

IT

AR

Y

MH

SI

GN

: N

OT

IC

E

SI

GN

: P

AR

KI

NG

PT

# 1

"C " C

UR

B

IN

LE

T

SI

GN

: P

AR

KI

NG

" O

AK

TE

LE

PH

ON

E

PU

LL

B

OX

PT

# 1

S

TO

RM

M H

EL

EC

. M

ET

ER

LIG

HT

P

OL

E

ON

CO

NC

B

AS

E

W

AT

ER

V

AV

LE

FI

RE

H

YD

RA

NT

EL

EC

. M

ET

ER

PT

# 1

S

AN

IT

AR

Y

MH

EL

EC

. M

ET

ER

SI

GN

: P

AR

KI

NG

SI

GN

: S

TE

ET

5'

CO

NC

RE

TE

W

AL

K

SI

GN

: N O

PA

RK

IN

G

SI

GN

: S

TO

P

" O

AK

6' W

RO

UG

HT

IR

ON

F

EN

CE

LIG

HT

P

OL

E

ON

C

ON

C.

B

AS

E

IR

RI

GA

TI

ON

C

ON

TR

OL

V

AL

VE

SI

GN

: S

TO

P

5' CONCRETE WALK

LIG

HT

P

OL

E W

AT

ER

M

ET

ER

4'

CO

NC

RE

TE

W

AL

K

SI

GN

: B

US

S

TO

P

PL

AN

TE

R

48" R.C.P.

" R

.C .P

8" S

TE

EL

8" STEEL

18" R.C.P.

18" R.C.P.

48" R.C.P.

" R

.C .P

" R .C

.P

" R

.C .P

12" R.C.P.

48" R.C.P. 48" R.C.P.

" R

.C .P

8"

STEEL

" R

.C .P

EL

EC

TR

IC

P

UL

L B

OX

(2

FF=46.78' FF=46.76'

105.0'

8.2

30.8'

.8'

9.1'

1.2 '1.9'

6" C.P.P.6"C.P.P.

6" C

.P .P

BULL ROCK

PT#13847 STORM MH

SI

GN

: N

OT

IC

E

EL

EC

TR

IC

M H

EL

EC

TR

IC

M H

2.5 'x1

.5' E

LE

C

TR

AN

S

T

T T

T

W

AT

ER

M

ET

ER

8" WL

8" WL

8" WL

6" W

L

+0

+0

10+00 11+00 12+00 13+00 14+00

ALTERNATE ADD:

NEW GRATE INLET

NEW STORM MANHOLE

NEW 18" RCP LEAD

REMOVE AND REPLACE

335 SF PVMT

A

R

EM

O

VE

E

XI

ST

L F

FH

L

EA

D

1-6" FH LEAD

1-6" GV&B

w/RES. JOINTS

SALVAGE EXIST FH

1-6"x8" TS&V

PROP 55 LF OF 6" WL

PVC C900 WITH

RESTRAINED JOINTS

CAP EXIST

6" WL

6'

TRNS 2.5X1.513362

42.05

TRNS 2.5X1.513365

43.18

TRNS 2.5X1.513366

42.48

10+00 11+00 12+00 13+00 14+00 14+60

FL

8" E

4.

FL

2" S

5.

EX

IS

T "T

Y- C

M H

" 3

R

IM

2.

EXIST 48" RCP

FL

8" E

4.

FL

8" N

4.

FL

8" W

3.

EX

IS

T "T

Y- C

M H

" 4

R

IM

1.

EXIST 48" RCP

EXIST "TY-C MH" 31

RIM = 42.16

FL 18" SW = 32.69

FL 48" W = 33.88

FL 18" N = 29.88

FL 48" E = 32.69

EXIST 18" RCP

EXIST 48" RCP

EXIST "TY-C MH" 9

RIM = 42.16

FL 24" N = 31.86

FL 48" W = 32.68

FL 24" SW = 34.96

FL 48" E = 29.86

EXIST 48" RCP

EXIST "TY-C MH" 29

RIM = 41.77

FL 18" NW = 32.67

FL 18" NE = 33.88

FL 18" S = 35.00

EXIST S

GUTTER

EXIST N

GUTTER

EXIST CENTERLINE

EXIST "TY-C" 73

RIM = 41.50

FL 18" S = 35.30

Revision # Date

22-008VA HOUSTON REPAIR ROADS-REWORK

NA

DRAWING NUMBER

VA PROJECT NUMBER

DATE

PROJECT TITLE

BUILDING NUMBERPROJECT LOCATION

CHECKED DRAWN

APPROVED: CHIEF, FACILITIES MANAGEMENT

on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

A

VA FORM 08-6231

Office of Construction and Facilities Management

DWG.

CONSULTANTS

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR

APPROVED: ACDS, RESEARCH AND DEVELOPMENT

1 2 3 4 5 6 7 8 9

B

C

D

E

F

A

B

C

D

E

F

SHEET TITLE

KWB DMH

MICHAEL E. DEBAKEY

VA MEDICAL CENTER

2002 HOLCOMBE BLVD

HOUSTON, TX 77030-4298

11/07/2022

CIVIL ENGINEER

100% CONSTRUCTION DOCUMENTS

TBPE FIRM REG NO. 8856

SURVEYOR

LUPHER, LLC

TEXAS PROFESSIONAL LAND

SURVEYORS

TBPLS FIRM REGISTRATION

NO. 10193807

5421 BRYSTONE DRIVE,

HOUSTON, TX 77041

(281) 501-8718

H2B, INC.

1225 N. LOOP WEST

SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PL

O

TT

ED

O N

/0 8/

1:

am

FI

LE

: C

:\U se rs \E liz ab et h.

Sh im ek \D

C \A

C C

D oc s\ H

2B , I nc -\M

ED

VA

M C

R ep ai r R oa ds

-R ew or k\

Pr oj ec t F ile s\

H 2B

P ro du ct io n\

C iv il\ C

S-

2A

R O

AD

W

AY

P

&P

C

AT

E

TE

R R

AC

E

(B

EG

IN

N

IN

G

0+

T

O S

TA

4+

).d w g

KENNETH W. BRYANT

85229

03/08/2023

1 ADDENDUM 1

20' 40'

SCALE: 1" = 20'

ALTERNATE ADD IF CATE TERRACE

PAVEMENT DEDUCT IS ACCEPTED

CS202A

M

AT

C

H

LI

N E

ST

A

+6

BENCHMARK: .

FLOODPLAIN REFERENCE MARK NUMBER 040105 IS AN HCFCD

BRASS DISK STAMPED D100 BM 14 ON BRIDGE AT BRAESWOOD

BOULEVARD & BRAYS, S. OF HOLCOMBE BOULEVARD LOCATED

ON DOWNSTREAM, E. SIDEWALK OF BRIDGE, AT STREAM

CENTER IN KEYMAP 533E IN THE BRAYS WATERSHED NEAR

STREAM D100-00-00.

ELEVATION 43.68 FEET NAVD 1988, 2001 ADJUSTED

NOTES: .

1. UTILITIES PRESENTED ON THESE DRAWINGS ARE SHOWN BASED

ON THE BEST AVAILABLE INFORMATION. CONTRACTOR SHALL

VERIFY THE EXACT LOCATIONS IN THE FIELD PRIOR TO

COMMENCING CONSTRUCTION. CONTRACTOR SHALL NOTIFY

LOCAL UTILITY LOCATING SERVICES AT LEAST 48 HOURS BEFORE

PROCEEDING WITH ANY EXCAVATION TO LOCATE PUBLIC

UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING

PRIVATE UTILITIES PRIOR TO ANY EXCAVATION.

2. ALL DIMENSIONS SHOWN ARE TO FACE OF CURB, UNLESS

OTHERWISE NOTED.

3. WHERE SAWCUTTING EXISTING PAVEMENT PERFORM FULL

DEPTH SAW CUT. USE HORIZONTAL DOWELS. DOWELS SHALL

BE GRADE 60 BARS, 24-INCHES LONG, DRILLED AND EMBEDDED

12-INCHES INTO THE CENTER OF THE EXISTING SLAB WITH PO

ROC, OR APPROVED EQUAL. DOWELS SHALL BE 12-INCHES

CENTER-TO-CENTER, UNLESS OTHERWISE SPECIFIED.

4. LIMITS OF DEMOLITION REQUIRED IS SHOWN IN SCHEMATIC

REPRESENTATION ONLY. LIMITS OF DEMOLITION TO BE VERIFIED

IN FIELD BY CONTRACTOR.

5. ALL DEMOLISHED MATERIAL TO BE DISPOSED OF OFF-SITE BY

CONTRACTOR.

6. WHERE REPLACING PAVEMENT, REMOVE EXISTING PAVEMENT,

BASE, AND CURB TO LIMITS SHOWN. CONSTRUCT NEW

PAVEMENT TO MATCH EXISTING ELEVATIONS WHERE

CONNECTING TO EXISTING PAVEMENT.

7. WHERE REPLACING SIDEWALK, REMOVE EXISTING CONCRETE TO

NEAREST JOINT. CONSTRUCT NEW CONCRETE SIDEWALK TO

MATCH EXISTING ELEVATIONS WHERE CONNECTING TO EXISTING

SIDEWALK.

8. SOD OR HYDRO-MULCH ALL DISTURBED AREAS.

9. ADA ACCESSIBLE RAMPS SHALL NOT EXCEED 5% GRADE AND

SHALL HAVE 5' LEVEL LANDINGS AT TOP AND BOTTOM OF RAMP.

RAMPS THAT HAVE CHANGE IN HEIGHT GREATER THAN 6" SHALL

HAVE HANDRAILS IN ACCORDANCE WITH ADA ACCESSIBILITY

STANDARDS. SIDEWALK SLOPES SHALL NOT EXCEED 3% AND

CROSS-SLOPE SHALL NOT EXCEED 2%.

10. CONCRETE SLOPE SHALL BE NO LESS THAN 0.50% EXCEPT

CONCRETE GUTTERS AND VALLEYS SHALL BE NO LESS THAN

0.35%.

11. WHERE PLACING NEW CURB INLETS ADJACENT TO EXISTING

PAVEMENT, PROVIDE INLET BOXOUT TO INCLUDE A 4-INCH

GUTTER DEPRESSION, AS SHOWN ON DETAIL 4/CS701.

12. CONTRACTOR TO VERIFY FLOWLINE AT ALL EXISTING INLETS

PRIOR TO BEGINNING CONSTRUCTION.

LEGEND: .

NEW NORTHBOUND PROFILE GRADE LINE (PGL)

NEW SOUTHBOUND PROFILE GRADE LINE (PGL)

PLAN VIEW:

PROFILE VIEW:

SAWCUT LINE

NEW STORM SEWER & MANHOLE

NEW 5-FOOT WIDE, 4 12" THICK CONCRETE

SIDEWALK REPLACEMENT (SEE NOTE 7)

NEW CONCRETE REPLACEMENT LIMITS

MATCH EXISTING(M.E.)

KEYED NOTES: .

REPLACE TO NEAREST EXISTING JOINT (SEE NOTE 3)

NEW 7" CONCRETE (ROADWAY REPLACEMENT) (SEE NOTE 6)

NEW 6" CONCRETE (PARKING REPLACEMENT) (SEE NOTE 6)

DEMOLITION NOTES:

PROPOSED NOTES:

J

SAWCUT (FULL DEPTH) (SEE NOTE 3)S

NEW 5-FOOT WIDE, 4 12" CONCRETE SIDEWALK (SEE NOTE 7)3

NEW 6" CONCRETE CURB4

NEW ADA RAMP @ 5% MAX SLOPE WITH TRUNCATED DOMES

DETECTIBLE WARNING STRIP5

ADJUST INLET TOP TO NEW GRADE6

NEW RETAINING WALL (RE: 3/CS702)7

EXISTING NORTHBOUND SOUTH GUTTER LINE

EXISTING SOUTHBOUND NORTH GUTTER LINE

NEW STORM SEWER & TYPE "A" GRATE INLET

NEW STORM SEWER & TYPE "C" CURB INLET

NORTHBOUND / SOUTHBOUNDNB / SB

ADJUST EXISTING FEATURE TO FINISHED GRADEA

REMOVE EXISTING STORM SEWER FEATURER

W

ES

T

AD

M

IN

R O

AD

CATE TERRACE

NEW ADA RAMP @ 5% MAX (RE: 5/CS702)5b

NEW ADA RAMP @ 5% MAX (RE: 2/CS702)5c

NEW ADA RAMP @ MAX (RE: 4/CS702)5a

REMOVE EXISTING HANDRAIL ALONG CURBRH

NEW ELECTRICAL LINEE

NEW ADA RAMP @ 5% MAX (RE: 1/CS702)5d

NEW NORTH & SOUTH PGL

(NORTH & SOUTH GUTTERS)

03/08/202303/23/2023

Sheets and Views
30x42

File details come from the government source that posted it. Updated .