A. GENERAL
1. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CODES. THE
CODES LISTED SHALL INCLUDE ALL AMENDMENTS AND ADDENDA IN FORCE AT THE DATE OF THE
CONTRACT DOCUMENTS.
2012 EDITION OF THE INTERNATIONAL BUILDING CODE
2. WHERE CONFLICT EXISTS AMONG THE VARIOUS PARTS OF THE STRUCTURAL AND
ARCHITECTURAL CONTRACT DOCUMENTS THE STRICTEST REQUIREMENTS SHALL GOVERN.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE
AND REPORT ANY DISCREPANCIES OR INCONSISTENCIES FROM ASSUMED CONDITIONS TO THE
ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION.
4. DETAILS LABELED “TYPICAL DETAILS” ON THE DRAWINGS SHALL APPLY TO ALL SITUATIONS
OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY
DETAILED. SUCH DETAILS APPLY WHETHER OR NOT THEY ARE CUT AT EACH LOCATION.
QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE DETERMINED BY THE
ENGINEER.
5. DO NOT SCALE THE DRAWINGS.
6. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL AND STRUCTURAL
DRAWINGS AND REPORT ANY DISCREPANCY BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH
SET OF DRAWINGS TO THE ARCHITECT AND ENGINEER PRIOR TO THE FABRICATION AND
INSTALLATION OF ANY STRUCTURAL MEMBERS.
7. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO OBTAIN ALL CONTRACT
DOCUMENTS AND LATEST ADDENDA AND TO SUBMIT SUCH DOCUMENTS TO ALL SUBCONTRACTORS
AND MATERIAL SUPPLIERS PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS, FABRICATION OF ANY
STRUCTURAL MEMBERS, AND ERECTION IN THE FIELD.
8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MEASURES NECESSARY TO
PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT ARE
NOT LIMITED TO, BRACING AND SHORING FOR LOADS DUE TO HYDROSTATIC, EARTH, WIND OR
SEISMIC FORCES, AND CONSTRUCTION EQUIPMENT. OBSERVATION VISITS TO THE SITE BY THE
ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS.
9. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL
SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION
MEANS, METHODS, PROCEDURES, TECHNIQUES, AND SEQUENCE.
10. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY FOR THE PURPOSE OF
DETERMINING IF THE WORK OF THE CONTRACTOR IS PROCEDING IN GENERAL ACCORDANCE WITH
THE STRUCTURAL CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION SHOULD NOT BE
CONSTRUED AS EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY OF THE WORK, BUT
RATHER PERIODIC IN AN EFFORT TO GUARD THE OWNER AGAINST DEFECTS OR DEFICIENCIES IN
THE WORK OF THE CONTRACTOR.
11. NOTIFY THE STRUCTURAL ENGINEER WHEN DRAWINGS BY OTHERS SHOW OPENINGS,
POCKETS, ETC., NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN THE
STRUCTURAL MEMBERS.
12. SEE THE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING:
SIZE AND LOCATION OF DOOR AND WINDOW OPENINGS,
SIZE AND LOCATION OF INTERIOR AND EXTERIOR NON-LOAD BEARING PARTITIONS,
SIZE AND LOCATION OF CONCRETE CURBS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS,
CHAMFERS, GROOVES, INSERTS, ETC.,
SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS,
FLOOR AND ROOF FINISHES,
STAIR FRAMING AND DETAILS,
DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS,
CEILING AND EXTERIOR WALL ASSEMBLIES.
13. SEE THE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE FOLLOWING:
PIPES, SLEEVES, HANGERS, TRENCHES, WALL FLOOR AND ROOF OPENINGS,
DUCT PENETRATIONS, ETC., EXCEPT AS SHOWN OR NOTED OTHERWISE
ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS,
CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL, OR PLUMBING FIXTURES,
SIZE AND LOCATION OF MACHINE OR EQUIPMENT BASES AND ANCHOR BOLTS FOR MOUNTS.
B. DESIGN CRITERIA
1. DEAD LOAD MATERIALS ASSUMED IN THE DESIGN ARE SHOWN ON THE ARCHITECTURAL AND
STRUCTURAL DRAWINGS.
2. AN ALLOWANCE OF 15 PSF HAS BEEN MADE FOR PARTITIONS AS A UNIFORMLY DISTRIBUTED LIVE LOAD, WHEREVER PARTITIONS ARE USED AND LOCATION SUBJECT TO CHANGE EXCLUDING PUBLIC
LOBBIES, CORRIDORS, RESTROOMS, AND PLACES OF PUBLIC ASSEMBLY.
3. LIVE LOADS
LOCATION UNIFORM LOAD CONCENTRATED LOAD
ROOF 20 PSF REDUCIBLE 300 LBS
TYPICAL FLOOR 40 PSF REDUCIBLE
CORRIDORS 100 PSF REDUCIBLE
STORAGE 125 PSF
4. WIND LOADS
ULTIMATE WIND SPEED, VULT 146 MPH (3-SEC GUST)
NOMINAL WIND SPEED, VASD 113 MPH (3-SEC GUST)
RISK CATEGORY III
EXPOSURE CATEGORY B
INTERNAL PRESSURE COEFF. +/- 0.18
COMPONENTS & CLADDING SEE PLAN
C. FOUNDATION
1. SLAB ON GRADE CONSTRUCTION SHALL FOLLOW THE RECOMMENDATIONS OF GUIDE FOR
CONCRETE FLOOR AND SLAB CONSTRUCTION ACI 302.1R. PROVIDE (2) #3 X 4’-0” TOP AND BOTTOM
AT ALL SLAB ON GRADE RE-ENTRANT CORNERS.
2. SUBGRADE PREPARATION SHALL CONFORM TO THE SOILS REPORT NOTED ABOVE. IF REPORT
DOES NOT SPECIFY THE AMOUNT OF SELECT FILL, PROVIDE FILL AS REQUIRED ABOVE TO REDUCE
PVR TO 1 INCH.
3. VAPOR RETARDER SHALL HAVE NO MORE THAN 0.01 PERMS AS TESTED BEFORE AND AFTER
MANDATORY CONDITIONING (ASTM E 1745 SECTION 7.1 AND SUB-PARAGRAPHS 7.1.2-5), MEET OR EXCEED THE REQUIREMENTS OF ASTM E 1745 CLASS A AND BE NO LESS THAN 15 MILS THICK.
4. ALL VAPOR RETARDER SEAMS SHALL BE OVERLAPPED A MINIMUM OF 6 INCHES AND TAPED WITH
MANUFACTURER'S TAPE. ALL PENETRATIONS, BLOCK-OUTS, AND OPENINGS SHALL BE SEALED
USING A COMBINATION OF THE VAPOR RETARDER,
D. CONCRETE
1. ALL ASPECTS OF WORK RELATING TO THE CONCRETE CONSTRUCTION SHALL CONFORM TO
THE FOLLOWING CODES AND SPECIFICATIONS:
ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
ACI 301-11 SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS
CRSI MANUAL OF STANDARD PRACTICE
2. STRUCTURAL CONCRETE 28-DAY COMPRESSIVE STRENGTHS AND TYPES ARE AS FOLLOWS:
LOCATION STRENGTH TYPE MAXIMUM AGGREGATE SIZE
GRADE BEAMS 3000 PSI NORMAL WT 1”
SLAB-ON-GRADE 3000 PSI NORMAL WT 1”
METAL DECK SLAB 3000 PSI LIGHTWEIGHT 3/4"
TOPPING SLAB 3000 PSI LIGHTWEIGHT 3/4"
3. THERE SHALL BE NO HORIZONTAL COLD JOINT IN ANY CONCRETE POUR.
4. ADMIXTURES USED SHALL BE COMPATIBLE WITH FLOOR TREATMENTS. FINISH APPLICATOR
SHALL APPROVE ADMIXTURES AND CURING COMPOUNDS PRIOR TO USE.
5. CONCRETE FOR SLAB-ON-GRADE SHALL HAVE A MAXIMUM WATER-CEMENT RATIO OF 0.45. ALL
OTHER CONCRETE SHALL HAVE A MAXIMUM WATER-CEMENT RATIO OF 0.50. ADJUST CONCRETE
STRENGTH BEYOND MINIMUM SPECIFIED ABOVE TO MAINTAIN MAXIMUM WATER-CEMENT RATIO.
6. FLY ASH CONFORMING TO ASTM C618, TYPE F, MAY BE USED UNLESS NOTED OTHERWISE. THE MAXIMUM AMOUNT OF FLY ASH SHALL BE 25% OF THE TOTAL CEMENTITIOUS MATERIAL BY WEIGHT.
7. CONCRETE FORMS SHALL BE LAID OUT AND CONSTRUCTED TO PROVIDE THE SPECIFIED
CAMBERS INDICATED ON THE STRUCTURAL DRAWINGS.
9. ROUGHEN CONCRETE SURFACES TO 1/4 INCH AMPLITUDE WHERE MASONRY WALLS INTERSECT
CONCRETE OR WHERE NEW CONCRETE INTERFACES WITH EXISTING CONCRETE.
10. MECHANICAL PIPES AND ELECTRICAL CONDUITS WHICH PASS THROUGH SLAB-ON-GRADE,
CONCRETE ON METAL DECK, FRAMED CONCRETE FLOORS, AND WALLS DO NOT REQUIRE
SLEEVES UNLESS NOTED OTHERWISE ON THE PROJECT SPECIFICATIONS, MECHANICAL OR
ELECTRICAL DRAWINGS. IF SLEEVES ARE REQUIRED, INSTALL SLEEVES BEFORE PLACING
CONCRETE. DO NOT CUT ANY REINFORCING WHICH MAY INTERFERE WITH SLEEVE PLACEMENT.
CORING OPENINGS IN CONCRETE IS NOT PERMITTED. NOTIFY THE ARCHITECT AND ENGINEER IN
ADVANCE OF CONDITIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS. NO PIPES OR
ELECTRICAL CONDUIT SHALL PASS THROUGH CONCRETE BEAMS OR COLUMNS UNLESS
SPECIFICALLY DETAILED.
11. WITH THE EXCEPTION OF SLABS ON GRADE AND CONCRETE ON METAL DECK, THE OUTSIDE
DIAMETER OF MECHANICAL PIPES AND/OR ELECTRICAL CONDUITS (OTHER THAN THOSE PASSING THROUGH) SHALL NOT EXCEED 1/3 OF THE SLAB THICKNESS AND SHALL BE CENTERED BETWEEN THE TOP AND BOTTOM REINFORCING UNLESS SPECIFICALLY DETAILED OTHERWISE. CONCENTRATIONS OF MECHANICAL PIPES AND/OR ELECTRICAL CONDUITS SHALL BE AVOIDED EXCEPT WHERE DETAILED OPENINGS ARE PROVIDED. CONDUIT AND PIPE SHALL BE SPACED AT 3” OR 3 DIAMETERS ON CENTER, WHICHEVER IS GREATER.
12. FOR SLABS ON GRADE AND METAL DECK SLABS NO PIPES OR CONDUITS SHALL BE PLACED
WITHIN THE INDICATED SLAB THICKNESS AND SHALL BE LOCATED BELOW THE SLAB UNLESS
SPECIFICALLY DETAILED OTHERWISE.
13. ALL CONCRETE SHALL BE PROPORTIONED FOR A MAXIMUM ALLOWABLE UNIT SHRINKAGE OF 0.03% AT 28 DAYS AFTER CURING IN LIME WATER AS DETERMINED BY ASTM C157 (USING AIR STORAGE).
14. THE DESIGN, CONSTRUCTION, AND SAFETY OF ALL FORMWORK SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ALL FORMS, SHORES, BACKSHORES, FALSEWORK, BRACING, AND OTHER TEMPORARY SUPPORTS SHALL BE ENGINEERED TO SUPPORT ALL LOADS IMPOSED INCLUDING THE WET WEIGHT OF CONCRETE, CONSTRUCTION EQUIPMENT, LIVE LOADS, LATERAL LOADS DUE TO WIND AND WET CONCRETE IMBALANCE. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR DETERMINING
WHEN TEMPORARY SUPPORTS, SHORES, BACKSHORES, AND OTHER BRACING MAY BE SAFELY
REMOVED.
15. THE GENERAL CONTRACTOR SHALL SUBMIT FOR OWNER'S RECORD ONLY, FORMWORK SHOP
DRAWINGS INCLUDING CALCULATIONS. FORMWORK SHOP DRAWINGS SHALL BE SEALED BY A
REGISTERED ENGINEER IN THE STATE THAT THE PROJECT IS LOCATED.
E. REINFORCING STEEL
1. ALL ASPECTS OF WORK RELATING TO THE REINFORCING STEEL SHALL CONFORM TO THE
FOLLOWING CODES AND SPECIFICATIONS:
ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
CRSI MANUAL OF STANDARD PRACTICE
2. DEFORMED BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615 GRADE 60.
3. WELDED WIRE FABRIC SHALL CONFORM TO THE REQUIREMENTS OF ASTM A185, YIELD STRENGTH 65,000 PSI. WELDED DEFORMED WIRE FABRIC FOR ASTM A497, YIELD STRENGTH 70,000 PSI. ALL
WELDED WIRE FABRIC SHALL BE FURNISHED IN FLAT SHEETS ONLY. WHEREVER WELDED WIRE
FABRIC IS SPECIFIED AS REINFORCEMENT, IT SHALL BE CONTINUOUS ACROSS THE ENTIRE CONCRETE SURFACE AND NOT INTERRUPTED BY BEAMS OR GIRDERS AND PROPERLY LAPPED ONE CROSS WIRE
SPACING PLUS 2 INCHES.
4. MINIMUM LAP OF WELDED WIRE FABRIC SHALL BE 6 INCHES OR ONE FULL MESH AND ONE HALF, WHICHEVER IS GREATER.
5. WELDING OF REINFORCING IS PERMITTED ONLY WHERE SHOWN ON THE DRAWINGS OR WHEN
APPROVED BY THE ENGINEER OF RECORD. WELDING OF REINFORCING BARS SHALL BE WITH LOW
HYDROGEN ELECTRODES IN ACCORDANCE WITH THE RECOMMENDED PRACTICES OF AWS D1.4.
6. ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
7. REINFORCING DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME
NUMBER, SIZE, SPACING, AND GRADE AS THE SPECIFIED VERTICAL REINFORCING, UNO.
8. IN ADDITION TO ALL OF THE REINFORCING STEEL INDICATED ON THE DRAWINGS, THE CONTRACTOR SHALL PROVIDE FOR AN ALLOWANCE OF A NET (0.5) TONS OF REINFORCING BARS TO BE FURNISHED, FABRICATED, AND PLACED DURING THE PROGRESSION OF WORK AS MAY BE DIRECTED BY THE
ENGINEER OF RECORD.
9. CLEAR COVERAGE OF CONCRETE OVER REINFORCING BARS SHALL BE AS FOLLOWS:
LOCATION OF CONCRETE MINIMUM COVER
CONCRETE NOT EXPOSED TO EARTH OR
WEATHER OR IN CONTACT WITH GROUND
SLABS, WALLS, JOISTS 3/4"
BEAMS, COLUMNS (INCLUDING TIES) 1 1/2"
SLAB ON GRADE 2” CLR FROM TOP
F. STRUCTURAL STEEL
1. ALL ASPECTS OF WORK RELATING TO THE DESIGN, FABRICATION, DETAILING, AND ERECTION OF
STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING CODES AND SPECIFICATIONS:
FOURTEENTH EDITION OF THE AISC STEEL CONSTRUCTION MANUAL
LATEST EDITION OF THE ANSI/AWS D1.1
2. STRUCTURAL STEEL MATERIALS SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS:
WIDE FLANGE ASTM A992
ANGLES, PLATES, BARS, CHANNELS ASTM A36 U.N.O.
HSS (RECTANGULAR OR SQUARE) ASTM A500 GR B (FY = 46 KSI)
ANCHOR RODS ASTM F1554-36 U.N.O
HIGH STRENGTH BOLTS ASTM A325N TYPE 1
HEADED STUD ANCHORS (HSA) ASTM A108
DEFORMED BAR ANCHORS (DBA) ASTM A496
3. THE DESIGN OF ALL STEEL CONNECTIONS SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION
OF A REGISTERED PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED,
EMPLOYED BY THE FABRICATOR. CALCULATIONS SEALED BY THE FABRICATOR’S PROFESSIONAL
ENGINEER MUST BE SUBMITTED IF REQUESTED.
4. STRUCTURAL STEEL NOT EXPOSED TO WEATHER SHALL BE LEFT UNPAINTED UNLESS NOTED
OTHERWISE IN THE ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS.
5. IT IS THE INTENTION OF THE PLANS AND SPECIFICATIONS THAT SHOP CONNECTIONS BE WELDED
OR BOLTED AND THAT FIELD CONNECTIONS BE BOLTED, UNLESS DETAILED OTHERWISE ON THE
DRAWINGS.
6. ALL TYPICAL BEAM SIMPLE CONNECTIONS SHALL BE STANDARD DOUBLE ANGLE OR SINGLE ANGLE
FRAMED BEAM CONNECTIONS. SHEAR TAB CONNECTIONS MAY BE USED AT LOCATIONS WHERE
DOUBLE ANGLE CONNECTIONS ARE NOT POSSIBLE. SEATED BEAM CONNECTIONS SHALL NOT BE USED UNLESS INDICATED ON THE DRAWINGS. PROVIDE FULL DEPTH SHEAR TAB IF BEAM FRAMES ON ONLY
ONE SIDE OF A GIRDER.
7. DESIGN CONNECTIONS OF NON-COMPOSITE BEAMS TO SUPPORT A REACTION R (UNLESS SPECIFIED OTHERWISE) EQUAL TO ONE HALF THE TOTAL UNIFORM LOAD CAPACITY FROM THE TABLE OF UNIFORM
LOAD CONSTANTS IN THE AISC MANUAL.
8. BEAM CONNECTIONS FOR COMPOSITE BEAMS SHALL BE DESIGNED FOR THE REACTIONS LISTED IN THE TABLE BELOW. ALL VALUES LISTED IN THE TABLE ARE ALLOWABLE STRESS DESIGN (ASD).
BEAM SIZE REACTION BEAM SIZE REACTION
W8 20 KIPS W21 100 KIPS
W10 20 KIPS W24 120 KIPS
W12 35 KIPS W30 180 KIPS
W14 40 KIPS W33 220 KIPS
W16 50 KIPS W36 280 KIPS
W18 65 KIPS
9. ADD TO THE REACTION LISTED ABOVE, ANY LOADS OR REACTIONS OF MEMBERS SUPPORTED BY THE BEAM WITHIN THREE FEET OF BEAM END AND THE VERTICAL COMPONENTS OF FORCES IN BRACE
MEMBERS FRAMING INTO THE BEAMS.
10. ALL WELDING SHALL COMPLY TO THE AMERICAN WELDING SOCIETY STANDARD (AWS D1.1). ALL WELDED JOINTS SHALL BE DETAILED AS INDICATED BY THE PREQUALIFIED JOINT DETAILS IN THE STRUCTURAL WELDING CODE. WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. WELD SIZE SHALL BE AISC MINIMUM UNLESS A LARGER SIZE IS NOTED. ALL
WELDS SHALL USE MINIMUM E70XX ELECTRODES.
11. ALL WELDING SHALL BE PERFORMED BY A WELDER CERTIFIED IN ACCORDANCE WITH THE AWS
STANDARDS.
12. MISCELLANEOUS STEEL CONNECTIONS SHALL BE WELDED ALL AROUND WITH AISC MINIMUM
FILLET WELD UNLESS A LARGER WELD IS SPECIFIED. STEEL MEMBERS CONTINUOUSLY ATTACHED SHALL BE STITCH WELDED TOGETHER WITH AISC MINIMUM 2” LONG FILLET WELD AT 12” O.C. UNLESS
A LARGER WELD OR DIFFERENT GAGE IS SPECIFIED.
13. ALL BOLTS SHALL BE DESIGNED AS BEARING BOLTS WITH THREADS INCLUDED IN THE SHEAR PLANE. ALL BOLTS SHALL BE NEW AND NOT RE-USED. BOLT HOLES IN STEEL SHALL BE 1/16 INCH LARGER THAN NOMINAL SIZE OF BOLT USED, EXCEPT ANCHOR ROD HOLES. MINIMUM BOLT DIAMETER SHALL BE 3/4 INCH. ALL BOLTS SHALL BE TIGHTENED TO A SNUG-TIGHT POSITION, EXCEPT AT BRACES, MOMENT CONNECTIONS AND CONNECTIONS MARKED AS SLIP CRITICAL (SC) SHALL BE TIGHTENED
USING LOAD INDICATING WASHERS OR TENSION BOLTS.
14. SHEAR STUDS AND THEIR INSTALLATION SHALL MEET ALL REQUIREMENTS OF AWS D1.1. STUD DIAMETER AND LENGTH SHALL BE 5/8 INCH DIAMETER X 4-3/8 INCH LONG BEFORE WELDING. STUDS SHALL BE WELDED IN THE FIELD (NOT THE SHOP) USING AUTOMATICALLY TIMED STUD WELDING EQUIPMENT. THE TOP FLANGE OF THE BEAM MUST BE UNPAINTED AND FREE OF HEAVY RUST, MILL
SCALE AND OTHER FOREIGN MATERIALS.
15. ALL STEEL EXPOSED TO WEATHER OR OUTSIDE THE BUILDING'S WATERPROOFING, SUCH AS BRICK SHELF ANGLES, SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION AS SPECIFIED BY THE STEEL STRUCTURES PAINTING COUNCIL (SSPC). THE ZINC COATING FOR STEEL SHAPES AND PLATES SHALL AVERAGE NOT LESS THAN 2.3 OZ. WITH NO INDIVIDUAL THICKNESS LESS THAN 2.0 OZ.
16. GALVANIZE ALL NUTS, BOLTS, AND WASHERS USED IN THE CONNECTION OF GALVANIZED STEEL.
17. GALVANIZED MEMBERS SHALL HAVE “Z.R.C. COLD GALVANIZING COMPOUND OR APPROVED
EQUIVALENT APPLIED TO FIELD WELDED CONNECTIONS. SURFACE AREAS TO RECEIVE COLD
GALVANIZING COMPOUND SHALL BE CLEAN OF DIRT AND DEBRIS PRIOR TO COMPOUND APPLICATION.
SEE MANUFACTURER’S LITERATURE FOR ADDITIONAL RECOMMENDATIONS.
18. THE APPLICATION OF THE FIREPROOFING TO THE STEEL MEMBERS AND STEEL DECK IS THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR MUST ENFORCE THE REQUIREMENTS OF THE MANUFACTURER AND NOT IMPOSE ADDITIONAL LOADS, INCLUDING CONSTRUCTION LIVE LOADS, DURING THE APPLICATION AND CURING OF THE FIREPROOFING.
19. IN ADDITION TO ALL OF THE STEEL INDICATED ON THE DRAWINGS, THE CONTRACTOR SHALL PROVIDE FOR AN ALLOWANCE OF A NET (1.2) TONS OF STEEL TO BE FURNISHED, FABRICATED, DETAILED, AND ERECTED DURING THE PROGRESSION OF WORK AS MAY BE DIRECTED BY THE
ENGINEER OF RECORD.
24. THE CONTRACTOR SHALL MAKE AN ALLOWANCE FOR THE ADJUSTMENT AND DETAILING OF STEEL
DURING THE SHOP DRAWING REVIEW PROCESS.
G. STEEL ROOF DECK (WITH RIGID INSULATION BOARD)
1. THE STEEL ROOF DECK SHALL BE OF THE TYPE AND GAUGE CALLED FOR ON DRAWINGS. STEEL
DECK SHALL BE MANUFACTURED FROM STEEL CONFORMING TO ASTM A653 STRUCTURAL QUALITY
GRADE 33 OR HIGHER. THE DESIGN, FABRICATION, AND ERECTION OF ALL ROOF DECK SHALL CONFORM
TO THE SDI MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS.
2. STEEL DECK SHALL BE GALVANIZED WITH A PROTECTIVE ZINC COATING CONFORMING TO ASTM A653-G90.
3. MINIMUM BEARING OF STEEL DECK ON SUPPORTS SHALL BE 2 INCHES. ALL 3 IN DEEP STEEL DECK SHALL HAVE A MINIMUM BEARING OF 3 INCHES. END LAPS OF SHEETS SHALL BE A MINIMUM OF 2 INCHES AND SHALL OCCUR OVER SUPPORTS. SHEETS SHALL BE ATTACHED TO SUPPORTING STEEL
MEMBERS BY WELDING AS INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH
MANUFACTURER’S RECOMMENDATIONS. UPON COMPLETION OF ERECTION, ALL WELDS ON STEEL
DECK SHALL BE DE-SLAGGED, CLEANED, AND TOUCHED UP WITH A ZINC RICH PRIMER.
4. PROVIDE ROOF DECK CONSTRUCTION WHICH IS LISTED AND CONFORMS TO THE UL FIRE
RESISTANCE DIRECTORY AND BUILDING MATERIALS DIRECTORY. DECK ATTACHMENT SHALL BE
INCREASED ABOVE THE MINIMUM SPECIFIED HEREIN AS REQUIRED TO ACHIEVE A CLASS 90 UPLIFT
RATING.
5. DECK SUPPORTED ON COLD-FORMED STEEL FRAMING SHALL BE ATTACHED TO EACH SUPPORT
MEMBER USING #12 TEK SCREWS AT ALL RIBS WHERE SIDES LAP AND EACH RIB IN BETWEEN.
6. PROVIDE MINIMUM 20 GAUGE RIDGE AND VALLEY PLATES, MINIMUM 20 GAUGE CANT STRIPS, MINIMUM 14 GAUGE SUMP PANS, MINIMUM 20 GAUGE INSIDE OR OUTSIDE CLOSURE CHANNELS, MINIMUM 20 GAUGE BUTT STRIPS AT CHANGE OF DECK DIRECTIONS, MINIMUM 20 GAUGE FILLER SHEETS, AND
RUBBER CLOSURES AS REQUIRED TO PROVIDE A FINISHED SURFACE FOR THE APPLICATION OF
INSULATION AND ROOFING.
7. DO NOT HANG LOADS FROM METAL DECK. PROVIDE ENGINEERED STRUCTURAL SYSTEM TO HANG ALL LOADS FROM STEEL JOISTS OR BEAMS. THIS INCLUDES BUT IS NOT LIMITED TO METAL STUD
SOFFIT OR CEILING FRAMING, MECHANICAL OR PLUMBING EQUIPMENT, ETC.
8. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, ETC., FOR SIZES AND LOCATIONS OF DECK OPENINGS AND FOR DECK OPENINGS SMALLER THAN 10 INCHES NOT SHOWN ON THE STRUCTURAL
DRAWINGS. ROOF OPENINGS LESS THAN 6 INCHES SQUARE OR DIAMETER REQUIRE NO
REINFORCEMENT. OPENINGS 6 INCHES TO 10 INCHES INCLUSIVE SHALL BE REINFORCED WITH A 20 GAUGE GALVANIZED PLATE WELDED TO THE DECK AT EACH CORNER AND 6 INCHES O.C. WITH 5/8 INCH DIAMETER PUDDLE WELDS OR SHEET METAL SCREWS. SEE TYPICAL DETAILS FOR FRAMING REQUIREMENTS AT OPENINGS LARGER THAN 10 INCHES. OPENINGS LARGER THAN 6 FEET SHALL BE
REFERRED TO THE ENGINEER FOR FRAMING.
9. METAL DECK SPANS SHALL NOT EXCEED THE MAXIMUM CENTER TO CENTER SPANS AS REQUIRED BY SDI. WHERE POSSIBLE, ALL METAL DECK SHALL EXTEND OVER THREE OR MORE SUPPORTS. TWO
SPAN DECK SHALL BE USED ONLY WHERE DECK LAYOUT DOES NOT PERMIT THE USE OF THREE
SPANS. SINGLE SPAN DECK IS NOT PERMITTED.
H. COLD-FORMED STEEL
1. ALL ASPECTS OF WORK RELATING TO COLD-FORMED (LIGHT GAGE) STEEL CONSTRUCTION SHALL
CONFORM TO THE FOLLOWING CODES AND SPECIFICATIONS:
2010 EDITION OF THE AISI SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL
MEMBERS, INCLUDING THE 2010 SUPPLEMENT
2. COLD-FORMED STEEL MEMBERS SHALL BE OF THE SIZE, GAUGE, AND SPACING SHOWN ON THE DRAWINGS. FLANGE WIDTHS SHALL BE 1 5/8” WITH 1/2" RETURNS UNLESS SPECIFIED OTHERWISE.
3. ALL FRAMING MEMBERS SHALL BE MANUFACTURED FROM CORROSION RESISTANT STEEL
CONFORMING TO ASTM A653 (G60). 25 GAUGE THROUGH 18 GAUGE MEMBERS SHALL BE FORMED FROM STEEL HAVING A MINIMUM 33 KSI YIELD POINT PER ASTM A653 GRADE 33. 16 GAUGE THROUGH 12 GAUGE MEMBERS SHALL BE FORMED FROM STEEL HAVING A MINIMUM 50 KSI YIELD POINT PER ASTM
A446 GRADE 50.
4. SPLICES IN FRAMING COMPONENTS EXCEPT RUNNERS AND TRACKS SHALL NOT BE PERMITTED.
5. AT LOAD BEARING WALLS SUPPORTING FLOOR OR ROOF JOISTS, LOCATE STUDS DIRECTLY UNDER
THE JOISTS OR PROVIDE LOAD DISTRIBUTING MEMBER BETWEEN STUDS TO SUPPORT JOISTS.
6. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING. WELDING SHALL BE DONE USING FILLET, PLUG, BUTT OR SEAM WELDS WITH A MINIMUM 3/32 IN. AWS TYPE 6013 WELDING RODS. WELD AREAS SHOULD BE RE-TOUCHED WITH THE APPROPRIATE PAINT OR COLD- GALVANIZING TO RETAIN CORROSION RESISTANCE. ALL WORK SHALL BE COMPLETED BY QUALIFIED
WELDERS IN ACCORDANCE WITH AWS D1.3 STANDARDS.
7. PROVIDE HORIZONTAL BRIDGING IN ALL STUD SYSTEMS AT 4’-0” O.C. VERTICALLY FOR AXIALLY
LOADED STUDS AND AT 6’-0” O.C. FOR NON-LOAD BEARING STUDS. WELD AT EACH STUD
INTERSECTION.
8. SCREWS SHALL BE SELF-DRILLING AND OF TYPE S-12, ASTM C-954, EXCEPT THAT TYPE S, ASTM C- 1002 MAY BE USED FOR 20 GAUGE OR 22 GAUGE MATERIAL ONLY. SCREWS SHALL BE 3/8” TO 1/2"
LONGER THAT TOTAL MATERTIAL THICKNESS.
9. SHEATHING MATERIALS FOR SHEARWALLS MUST EXTEND AND BE CONNECTED TO THE TOP AND
BOTTOM TRACKS.
10. STEEL STRUCTURAL STUD TRACK OF THE SAME GAUGE AS THE STUDS SHALL BE USED AT THE TOP AND BOTTOM OF ALL STUD WALLS UNLESS NOTED OTHERWISE. STUDS SHALL SIT FLAT AGAINST THE WEB OF THE STUD TRACK AND BE ATTACHED WITH 1-#8 X 5/8” SCREW EACH SIDE OF EACH STUD.
11. WEB PUNCH-OUTS SHOULD BE COORDINATED WITH BRACING AND UTILITY REQUIREMENTS. WEB PUNCH-OUTS OR WEB OPENINGS SHALL BE LOCATED A MINIMUM OF 6” OR MEMBER DEPTH, WHICHEVER
IS GREATER, FROM STUD OR JOIST BEARING POINTS.
12. ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR
MEMBERS, OR AS REQUIRED FOR AN ANGULAR FIT AGAINST ABUTTING MEMBERS.
13. FOR NON-LOAD BEARING STUDS, CONNECTIONS SHALL ACCOUNT FOR THE DEFLECTION OF THE STRUCTURAL MEMBERS TO WHICH THE STUDS ARE ATTACHED (1/2” MINIMUM). PROVIDE SLIDING CLIPS
AND/OR SLIP TRACKS.
14. JACK STUDS OR CRIPPLES SHALL BE INSTALLED BELOW WINDOW SILLS, ABOVE WINDOW AND
DOOR HEADS, AND ELSEWHERE TO FURNISH SUPPORT, AND SHALL BE SECURELY ATTACHED TO
CONNECTING MEMBERS.
15. PRIOR TO FABRICATION, THE CONTRACTOR SHALL SUBMIT ERECTION DRAWINGS TO THE
ARCHITECT AND ENGINEER OF RECORD FOR REVIEW AND APPROVAL.
16. TRACK SHALL BE SECURELY ANCHORED TO THE SUPPORTING STRUCTURE. ABUTTING PIECES OF
TRACK SHALL BE SECURELY SPLICED TOGETHER.
17. THE DESIGN OF ALL COLD-FORMED STEEL SHALL BE PERFORMED BY THE COLD-FORMED METAL CONTRACTOR. THE DESIGN SHALL INCLUDE MEMBER SIZES AND CONNECTION. THE DESIGN SHALL CONSIDER MEMBER DIMENSIONS NOTED ON THE DRAWINGS. THE COLD-FORMED CONTRACTOR SHALL SUPPLY DRAWINGS SEALED BY AN ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. THE OUT-OF-PLANE DEFLECTION OF STUDS SHALL BE LIMITED TO H/600 (H = UNSUPPORTED
HEIGHT OF STUDS) IF USED FOR MASONRY OR STONE BACKUP. FOR OTHER CONDITIONS THE
DEFLECTION SHALL BE LIMITED TO H/360.
K. SUBMITTALS
1. THE GENERAL CONTRACTOR SHALL SUBMIT FOR ENGINEER REVIEW SHOP DRAWINGS FOR THE
FOLLOWING ITEMS:
CONCRETE MIX DESIGNS
REINFORCING STEEL
STRUCTURAL STEEL (*)
METAL DECK
MISCELLANEOUS STEEL
ITEMS MARKED (*) SHALL HAVE SHOP DRAWINGS SEALED BY A REGISTERED ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED. ITEMS MARKED (#) SHALL BE SUBMITTED TO ENGINEER FOR
OWNER'S RECORD ONLY AND WILL NOT HAVE ENGINEER'S SHOP DRAWING STAMP.
2. ALL SHOP DRAWINGS MUST BE REVIEWED AND SEALED BY THE GENERAL CONTRACTOR PRIOR TO
SUBMITTAL.
3. CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES (E.G. PDFS) OF ALL SHOP DRAWINGS SPECIFIED
TO BE RETURNED BY THE ENGINEER.
4. THE OMISSION FROM THE SHOP DRAWINGS OF ANY MATERIAL REQUIRED BY THE CONTRACT
DOCUMENTS TO BE FURNISHED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF FURNISHING AND INSTALLING SUCH MATERIALS, REGARDLESS OF WHETHER THE SHOP DRAWINGS
HAVE BEEN REVIEWED AND APPROVED.
5. SUBMIT TWO COPIES OF MANUFACTURER'S LITERATURE FOR ALL MATERIALS AND PRODUCTS USED
IN CONSTRUCTION ON THE PROJECT.
6. THE USE OF REPRODUCTIONS OF THESE CONTRACT DOCUMENTS BY ANY CONTRACTOR,
SUBCONTRACTOR, ERECTOR, FABRICATOR, OR MATERIAL SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFIES HIS ACCEPTANCE OF ALL INFORMATION SHOWN HEREIN AS CORRECT, AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT
MAY OCCUR HEREIN.
L. SPECIAL INSPECTION
1. ALL ASPECTS OF WORK RELATING TO SPECIAL INSPECTION SHALL CONFORM TO THE
FOLLOWING CODES AND SPECIFICATIONS:
2012 INTERNATIONAL BUILDING CODE (CHAPTER 17).
2. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE
COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE
PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION.
3. PRIOR TO THE BEGINNING OF CONSTRUCTION, THE ARCHITECT (OR ENGINEER) SHALL
CALL A PRE-CONSTRUCTION MEETING WITH THE ARCHITECT, ENGINEER, BUILDING OFFICIAL,
CONTRACTOR AND SPECIAL INSPECTORS TO REVIEW THE SPECIAL INSPECTION
REQUIREMENTS.
4. DUTIES OF THE SPECIAL INSPECTOR INCLUDE (BUT ARE NOT LIMITED TO):
(A) ACKNOWLEDGE THE SPECIAL INSPECTION AND TESTING AGREEMENT PROVIDED BY THE
LOCAL JURISDICTION.
(B) THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK FOR CONFORMANCE WITH
THE APPROVED CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF
UNCORRECTED TO THE ENGINEER AND TO THE BUILDING OFFICIAL.
(C) THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS FOR EACH
INSPECTION TO THE BUILDING OFFICIAL, ARCHITECT, ENGINEER, CONTRACTOR AND (OTHER
DESIGNATED PARTIES), IN A TIMELY MANNER, AS ESTABLISHED AT THE PRE-CONSTRUCTION
MEETING.
(D) THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT STATING WHETHER THE
WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTOR’S
KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THE
APPLICABLE WORKMANSHIP PROVISIONS OF THE INTERNATIONAL BUILDING CODE.
5. DUTIES OF THE CONTRACTOR INCLUDE (BUT ARE NOT LIMITED TO):
(A) NOTIFY THE SPECIAL INSPECTOR THAT THE WORK IS READY FOR INSPECTION AT
LEAST 24 HOURS BEFORE SUCH INSPECTION.
(B) ALL WORK REQUIRING SPECIAL INSPECTION SHALL REMAIN ACCESSIBLE AND
EXPOSED UNTIL IT HAS BEEN OBSERVED AND INDICATED TO BE IN CONFORMANCE BY THE
SPECIAL INSPECTOR AND APPROVED BY THE BUILDING OFFICIAL.
(C) PROVIDE THE SPECIAL INSPECTOR WITH ACCESS TO APPROVED CONSTRUCTION
DOCUMENTS AT JOBSITE.
(D) MAINTAIN AT THE JOBSITE COPIES OF ALL REPORTS SUBMITTED BY THE SPECIAL
INSPECTOR.
6. CONTINUOUS INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT ALL
TIMES OBSERVING THE WORK REQUIRING SPECIAL INSPECTION.
7. PERIODIC INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT TIME
INTERVALS NECESSARY TO CONFIRM THAT THE WORK REQUIRING SPECIAL INSPECTION IS IN
CONFORMANCE WITH APPROVED CONSTRUCTION DOCUMENTS.
8. TYPES OF WORK THAT REQUIRE SPECIAL INSPECTION
CONCRETE
PLACING OF REINFORCED CONCRETE CONTINUOUS
TAKING OF SPECIMENS CONTINUOUS
BOLTS CAST IN CONCRETE PERIODIC
PLACEMENT OF REINFORCING STEEL PERIODIC
STRUCTURAL WELDING AND HIGH STRENGTH
BOLTING FILLET WELDS EXCEEDING 5/16 INCH CONTINUOUS
GROOVE WELDS CONTINUOUS
SINGLE PASS FILLET WELDS NOT PERIODIC
EXCEEDING 5/16 INCH
FLOOR AND DECK WELDING PERIODIC
WELDED STUDS PERIODIC
WELDED COLD-FORMED FRAMING PERIODIC
WELDED STAIR AND RAILING PERIODIC
HIGH STRENGTH BOLTING PERIODIC
OTHER
SPRAY-APPPLIED FIREPROOFING PERIODIC
EXPANSION BOLT INSTALLATION PER ICBO EVALUATION REPORT
M. LIGHT-GAGE TRUSSES
1. ALL STRUCTURAL MEMBERS AND CONNECTIONS SHALL BE DESIGNED AND ERECTED PER
THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATIONS NOTED ABOVE.
2. ALL TRUSSES SHALL BE FORMED FROM CORROSION RESISTANT STEEL CONFORMING TO
ASTM A 446 WITH A MINIMUM YIELD STRENGTH OF 50 KSI. BRIDGING MEMBERS SHALL HAVE
A MINIMUM YIELD STRENGTH OF 33 KSI.
3. PRIOR TO FABRICATION, THE CONTRACTOR SHALL SUBMIT ERECTION DRAWINGS TO
STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL.
4. TRUSS MANUFACTURER SHALL PROVIDE TRUSS SUBMITTALS REQUIRED BY THE ENTITY
WITH JURISDICTION.
5. PROPOSED CONNECTION TO STRUCTURAL SHALL BE SUBMITTED FOR APPROVAL UNLESS
SPECIFIED OTHERWISE ON DRAWINGS.
6. SUBMIT TRUSS SHOP DRAWINGS TO A/E FOR REVIEW PRIOR TO FABRICATION.
7. TRUSSES ARE TO BE DESIGNED BY THE MANUFACTURER FOR LOADS DEFINED IN THE
GENERAL NOTES. TRUSS DRAWINGS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL
ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED.
8. TRUSSES SHALL FOLLOW ROOF PROFILE EXCEPT AT OVERLAY CONDITIONS.
9. PROVIDE BRIDGING BETWEEN TRUSSES AS REQUIRED.
10. SEE ARCHITECTURAL DRAWINGS FOR ROOF SLOPES.
11. AT LOCATIONS WHERE ROOF OPENING WIDTHS EXCEED RAFTER OR TRUSS SPACING,
DOUBLE MEMBERS AT SIDES OF OPENINGS AND PROVIDE DOUBLE MEMBER HEADERS.
MAXIMUM SPACINGS INDICATED SHALL BE MAINTAINED.
12. SEE ARCHITECTURAL AND MECHANICAL FOR LOCATION OF MECHANICAL UNITS AND
ATTIC ACCESS LOCATION. ADJUST TRUSS LOCATIONS AND PROFILES AS REQUIRED.
13. COORDINATE TRUSS PROFILES WITH CEILING AND PLATE HEIGHTS. SEE
ARCHITECTURAL FOR MORE INFORMATION.
14. AT THE LOAD BEARING WALLS SUPPORTING FLOOR OR ROOF TRUSSES, LOCATE STUDS
DIRECTLY UNDER THE JOISTS OR PROVIDE LOAD DISTRIBUTING MEMBER BETWEEN STUDS
TO SUPPORT JOISTS.
15. TRUSS DESIGN SHALL CONSIDER LOAD FROM HVAC UNITS, FURR DOWNS, AND FOLDING
PARTITIONS.
16. DESIGN TRUSSES FOR A MAXIMUM DEFLECTION OF L/360 FOR LIVE LOAD AND L/240 FOR
TOTAL LOAD.
17. AT SCISSOR TRUSSES, LIMIT HORIZONTAL LIVE LOAD DEFLECTION TO THE WALL HEIGHT
DIVIDED BY 360 WITH A MAXIMUM OF 1/2”. THE CONNECTION TO THE WALL SHALL
ACCOMMODATE LATERAL MOVEMENT UNDER DEAD LOADS.
18. ERECT FRAMING AND TRUSSES PLUMB, LEVEL AND SQUARE IN STRICT ACCORDANCE TO
APPROVED SHOP DRAWINGS.
19. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING OF
SUFFICIENT SIZE TO ENSURE THE STRENGTH OF THE CONNECTION.
20. FASTEN EACH TRUSS TO TOP PLATE WITH SIMPSON CONNECTIONS WITH ADEQUATE
CAPACITY FOR UPLIFT. TRUSS SUPPLIER SHALL SELECT AND FURNISH CONNECTORS.
MINIMUM CONNECTOR SHALL BE SIMPSON H7.
21. JACK STUDS OR CRIPPLES SHALL BE INSTALLED AS REQUIRED.
22. PROVIDE STUD BRACING DURING CONSTRUCTION AS REQUIRED FOR STUDS TO CARRY
UPLIFT LOADS.
23. ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO
PERPENDICULAR MEMBERS, OR AS REQUIRED FOR AN ANGULAR FIT AGAINST ABUTTING
MEMBERS.
24. PROVIDE TRUSS HANGERS AT ALL NON-BEARING TRUSS-TRUSS CONNECTIONS.
25 COORDINATE BEARING CONNECTIONS OF TRUSSES WITH CEILING.
26. BLOCK BETWEEN TRUSSES AT RIDGE.
P. STEEL COMPOSITE DECK (FLOORS)
1. SCHEDULED FLOOR DECK SHALL BE 2VLI (18 GAUGE) AS MANUFACTURED BY VULCRAFT OR
EQUIVALENT.
2. THE DESIGN, FABRICATION, AND ERECTION OF ALL FLOOR DECK SHALL CONFORM TO THE STEEL
DECK INSTITUTE DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS AS
PUBLISHED BY THE STEEL DECK INSTITUTE (SDI).
3. STEEL DECK SHALL BE MANUFACTURED FROM STEEL CONFORMING TO ASTM A 653-94, STRUCTURAL QUALITY GRADE 33 OR HIGHER. SHEET METAL ACCESSORIES SHALL CONFORM TO ASTM A653-94, STRUCTURAL QUALITY.
4. STEEL DECK SHALL BE GALVANIZED WITH A PROTECTIVE ZINC COATING CONFORMING TO ASTM A 653-
94 G60 CLASS..
5. MINIMUM BEARING OF STEEL DECK ON SUPPORTS SHALL BE 2 INCHES. SHEETS SHALL BE ATTACHED
TO ALL SUPPORTING STEEL MEMBERS BY WELDING AS INDICATED ON THE DRAWINGS AND IN
ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. UPON COMPLETION OF ERECTION, ALL
WELDS ON STEEL DECK AREAS EXPOSED TO WEATHER SHALL BE DE-SLAGGED, CLEANED AND
TOUCHED-UP WITH A ZINC RICH PRIMER.
6. DECK ENDS SHALL BE BUTTED OVER SUPPORTS..
7. METAL DECK SPANS SHALL NOT EXCEED THE MAXIMUM CENTER TO CENTER SPANS AS REQUIRED BY SDI CRITERIA. WHERE POSSIBLE, ALL METAL DECK SHALL EXTEND OVER THREE OR MORE SUPPORTS.
TWO SPAN DECK SHALL BE USED ONLY WHERE DECK LAYOUT DOES NOT PERMIT THE USE OF THREE
SPANS. SINGLE SPAN DECK IS NOT PERMITTED. ALL DECK SHALL BE DESIGNED AS UNSHORED
CONSTRUCTION UNLESS NOTED OTHERWISE.
8. THE USE OF ADMIXTURES IN CONCRETE CONTAINING CHLORIDE SALTS SHALL NOT BE PERMITTED FOR
METAL DECK CONCRETE.
9. THE GENERAL CONTRACTOR SHALL INCLUDE IN THEIR BID ADDITIONAL CONCRETE REQUIRED FOR
METAL DECK SLABS TO ACCOUNT FOR DECK DEFLECTION.
10. WELDING WASHERS SHALL BE USED ON ALL DECK UNITS WITH METAL THICKNESS LESS THAN 0.028 INCHES THICK. WELDING WASHERS SHALL BE A MINIMUM THICKNESS OF 0.0568 INCHES AND HAVE A NOMINAL 3/8 INCH DIAMETER HOLE. WHERE WELDING WASHERS ARE NOT REQUIRED A NOMINAL 5/8 INCH DIAMETER PUDDLE WELD SHALL BE USED. WELD METAL SHALL PENETRATE ALL LAYERS OF DECK MATERIAL AT END LAPS AND SIDE JOINTS AND SHALL HAVE GOOD FUSION TO THE SUPPORTING
MEMBERS.
11. OPENINGS LESS THAN 6 INCHES SQUARE OR DIAMETER REQUIRE NO REINFORCEMENT. OPENINGS 6 INCHES TO 10 INCHES INCLUSIVE SHALL BE REINFORCED WITH A 20 GAUGE GALVANIZED PLATE WELDED TO THE DECK AT EACH CORNER AND 6 INCH MAXIMUM CENTERS WITH 5/8 INCH DIAMETER PUDDLE WELD OR SHEET METAL SCREWS. OPENINGS OVER 10 INCHES WIDE OR DIAMETER SHALL BE REINFORCED WITH AN ANGLE 2 1/2 X 2 1/2 X 1/4 FRAMING EACH SIDE OF THE OPENING AND SPANNING BETWEEN SUPPORTS FOR SPANS 4 FEET BUT LESS THAN 6 FEET. LARGER OPENINGS SHALL BE REFERRED TO
THE ENGINEER OF RECORD FOR FRAMING.
12. METAL DECK MANUFACTURER SHALL FURNISH SHEET METAL CLOSURES AT ALL SLAB EDGES, COLUMNS, WALLS, AND OPENINGS UNLESS STEEL ANGLES OR PLATES ARE SPECIFIED IN DETAILS ON THE DRAWINGS. SUCH CLOSURES SHALL BE MINIMUM 14 GAGE COLD FORMED STEEL WELDED TO EDGE SUPPORTS WITH 1 INCH LONG WELD AT 12" MAXIMUM CENTERS. PROVIDE 2" MINIMUM BEARING OVER
STEEL SUPPORT. CLOSURES AND SUPPORT WELDS SHALL BE DESIGNED TO SUPPORT THE WET
CONCRETE WEIGHT AND A 150 POUND CONCENTRATED LOAD ACTING AT THE SLAB EDGE WITHOUT EXCEEDING A STRESS OF 0.8 FY; AND THE WET CONCRETE WEIGHT ALONE WITHOUT EXCEEDING A STRESS OF 0.6 FY AND A DEFLECTION OF 3/4" MAXIMUM. PROVIDE SHEET METAL CLOSURES FOR OPEN
ENDS OF PANELS WHERE DECK STOPS OR CHANGES DIRECTION.
13. METAL DECK UNITS SHALL BE WELDED TO EACH STRUCTURAL STEEL SUPPORT AT EACH SIDE LAP AND AT RIBS IN BETWEEN WITH SPACING BETWEEN WELDS NOT TO EXCEED 12 INCHES ON CENTER (FOUR FASTENERS PER SHEET MINIMUM). SIDE LAP OF ADJACENT UNITS SHALL BE FASTENED BY SHEET
METAL SCREWS, SO THAT SPACING BETWEEN SUPPORTS AND FASTENERS DOES NOT EXCEED 36
INCHES.
66260
JAYNOOL A. KHAYRATTEE
R E
E
O R
P
D
EE
R
S A
XETFOET
A
T S
NI
GNELANOIS
S E
F
RETSI
G
Matrix Structural Engineers TBPE Firm Registration No. F-2640
E N G I N E E R S
S T R U C T U R A L
M A T R I X
5177 RICHMOND AVE.
SUITE 670
HOUSTON, TEXAS 77056
PHONE: (713) 664-0130
FAX: (713) 664-1370
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
Drawing Number
DrawnChecked
Dwg. of 212 Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
MSE 14199
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
06.08.2018
SHJK06/08/18
S-001
GENERAL NOTES CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON TX 77030
#580-320
36Issued for Bidding & Construction 06/08/2018
PLAN NOTES:
1. LOCATIONS SHOWN THUS: T.O.S. INDICATES TOP OF STEEL (T.O.S.) ELEVATION
(TOP OF STEEL = TOP OF JOIST OR BOTTOM OF DECK).
2. FIELD VERIFY ALL EXISTING CONDITONS AND DIMENSIONS PRIOR TO
FABRICATION / CONSTRUCTION.
3. SPACE BEAMS EQUALLY, U.N.O.
4. PROVIDE 3/16" CLOSURE PLATES AT ALL TUBE BEAMS.
5. REFER TO ARCHITECTURAL DRAWINGS / MEP FOR LOCATIONS OF ROOF DRAINS,
OVERFLOW DRAINS AND TAPERED INSULATION.
6. OR MC = MOMENT CONNECTION
LSH = LONG SIDE HORIZONTAL
LSV = LONG SIDE VERTICAL
L.P. = LOW POINT
LL
L.1L.1
MM
M.9M.9
NN
11 10 911.4
24' - 6" 12' - 0" 36' - 6" 33' - 6" 3' - 0"
9.1
W12X19 W14X22 W14X22
W14X22 C = 1/2"
W14X22 C = 1/2"
W14X22 C = 1/2"W8X10
W8X10
W8X10
W8X10
W8X10
W X
W X
C
/4
W14X22 C = 1/2"
W14X22 C = 1/2"
W14X22 C = 1/2"
W14X22 C = 1/2"W14X22 C = 1/2"
W X
C
/4
W14X22 C = 1/2" W14X22 C = 1/2"
(BENT BM.)
W14X22 C = 1/2" W14X22 C = 1/2"
W X
C
/4
W X
C
/4
W14X22 C = 1/2"W14X22 C = 1/2"W8X10
W12X19
W X
W8X10 W14X22 C = 1/2" W14X22 C = 1/2"
W14X22 C = 1/2"W14X22 C = 1/2"W8X10
W8X10 W14X22 C = 1/2" W14X22 C = 1/2"
W14X22 C = 1/2"W14X22 C = 1/2"W8X10
W12X19 W14X22 C = 1/2" W14X22 C = 1/2"
W X
C
/4
W X
C
/4
72' - 4 1/4"
SPLICE
EXISTING COLUMN
ROOF DECK:
1.5B (22 GAGE)
GALV. (G90)
SEE GEN. NOTES
72' - 4 1/4"72' - 4 1/4"
71' - 7 1/2"
72' - 4 1/4"72' - 4 1/4"
72' - 4 1/4"72' - 4 1/4"
72' - 4 1/4"
72' - 4 1/4" 72' - 4 1/4"
1' - 6"
/2
E .J
1' - 6"
1" EXP.JT. (TYP. ALL AROUND)
/2
E .J
OUTLINE OF
BUILDING LINE
S-402
S-402
S-402
S-402
71' - 7 1/2"
11' - 0"
EXISTING
BUILDING
(LEVEL 2)
EXISTING
BUILDING
(LEVEL 2)
EXISTING
BUILDING
(LEVEL 2)
EXISTING
BUILDING
(LEVEL 2)
EXISTING
COURT
BELOW
/2
1' - 6" 1' - 6"
SLOPESLOPE
71' - 11 5/8"
S L O
P E
S L O
P E
LL
L.1L.1
M
M.9
N
11 10 911.4 9.1
W8X40
W8X24W8X40 W8X40
W8X40 W8X40
W8X40 W8X24 W8X24
W8X24 W8X24
W12X16 (20) C = 3/4"
W12X14 (10)
W10X12 (4SL)
W10X12 (2)
W10X12 (4)
W12X16 (10)
W12X16 (26) C = 1 1/4"
W16X26 (24) C = 1"
W16X31 (52) C = 1 3/4"
S-301
S-301
S-301
6A
S-301
S-301
S-301
SIM.
W8X24
2" COMPOSITE
METAL DECK, SEE
GENERAL NOTES
S-301
1' - 4"
/2
/8
S-301
2" COMPOSITE
METAL DECK, SEE
GENERAL NOTES
S-301
SIM.
1' - 4"
24' - 6" 12' - 0" 36' - 6" 33' - 6" 3' - 0"
/2
/2
DETERMINE
FIELD
CONCRETE TOPPING SLAB
OVER RIGID FOAM REINF.
WITH WWF 6x6-W2.1xW2.1
PAVERS
SIM.
7' - 11 1/2"
DETERMINE
FIELD
OUTLINE OF EXISTING
PLANTER WALLS (TYP.) -
FIELD VERIFY LOCATION
/2
/4 "4
/4
S-301
4' - 2 1/2"
66260
JAYNOOL A. KHAYRATTEE
R E
E
O R
P
D
EE
R
S A
XETFOET
A
T S
NI
GNELANOIS
S E
F
RETSI
G
Matrix Structural Engineers TBPE Firm Registration No. F-2640
E N G I N E E R S
S T R U C T U R A L
M A T R I X
5177 RICHMOND AVE.
SUITE 670
HOUSTON, TEXAS 77056
PHONE: (713) 664-0130
FAX: (713) 664-1370
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
Drawing Number
DrawnChecked
Dwg. of 212 Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
MSE 14199
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
06.08.2018
SHJK06/08/18
S-201
ADDITIONAL FRAMING PLAN CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON TX 77030
#580-320
SCALE: 1/8" = 1'-0"2
ROOF FRAMING PLAN
SCALE: 1/8" = 1'-0"1
LEVEL 1 FLOOR FRAMING PLAN
Issued for Bidding & Construction 06/08/2018
56' - 0"
55' - 4"
REMOVE
RIGID FOAM
REMOVE SOIL
E X
IS
IT
N G
CONC. SLAB, SEE PLAN
1/4" STIFF. PLATE
W6 x 6 - W2.1 x W2.1
REMOVE
RIGID FOAM
REMOVE SOIL
56' - 0"
(MAX.)
5' - 0" (TYP.)
CONC. SLAB,
SEE PLAN
W6 x 6 - W2.1 x W2.1
6"3" MIN.
REMOVE
RIGID FOAM
REMOVE SOIL
56' - 0"
CONC. SLAB,
SEE PLAN 6"
W6 x 6 - W2.1 x W2.1
1NO SCALE
2NO SCALE
3NO SCALE
4NO SCALE
6, 6A (NOTED)NO SCALE
7NO SCALE
8NO SCALE
9NO SCALE
10SCALE: 3/4" = 1'-0"
11NO SCALE
12NO SCALE
13SCALE: 3/4" = 1'-0"
14NO SCALE
15NO SCALE
EXT. FINISH &
STUD WALL,
RE: ARCH.
ROUGHEN
SURFACE
(1)-#4 CONT.
NEW CONC. SLAB
ON RIGID FOAM
#3 @ 12" (DRILL
2" INTO EXISTING
CONC. & EPOXY)
EXISTING CONCRETE
SLAB-ON METAL DECK
SEE PLAN
6" 6"
PAVERS
(RE: ARCH.)
1' - 0" 1' - 0"
(RE: ARCH.)
DEPRESSED SLAB
R E
A
R C
H
RE: ARCH.
4" 4"
8"
#3 @ 15" DOWELS x1'-2"
LONG, DRILL 4" INTO
EXISTING & SET WITH
EPOXY, BEND BARS
AFTER INSTALLATION
8"
TYPICAL DETAIL
DEPRESSION AT SLAB-ON-GRADE
15MIL VAPOR
RETARDER
#3 @ 15" O.C.
EA. WAY
REMOVE
W6 x 6 - W2.1 x W2.1
/2
CONC. SLAB,
SEE PLAN.
TOP OF SLAB TO
MATCH EXIST.
REMOVE SOIL
1/4" STIFF. PLATE
55' - 4" (V.I.F.)
VARIES
PAVERS (RE: ARCH.)
6" 6"
SEE DETAIL 10
FOR REINF.
REMOVE
56' - 0"
CONC. SLAB,
SEE PLAN
/2
55' - 4" (V.I.F.)
L4x4x3/8 (CONT.) TO
SUPPORT DECK IN
BETWEEN BEAM/WALL
SUPPORT (TYP.)
DECK DIRECTION
CHANGES AT 6A
55' - 4" (V.I.F.)
REMOVE
E X
IS
IT
N G
RIGID FOAM
CONC. SLAB,
SEE PLAN.
L4x4x3/8 (CONT.) TO SUPPORT
DECK IN BETWEEN BEAM/WALL
SUPPORT (TYP.)
6" 6" PAVERS
(RE: ARCH.)
(1)-#4 CONT.
VARIES
#3 @ 12"
6"
NEW CONC. SLAB
ON RIGID FOAM
REMOVE
REMOVE SOIL
CONC. SLAB,
SEE PLAN
/2
55' - 4" (V.I.F.)
L4x4x3/8 (CONT.) TO
SUPPORT DECK ALONG
EDGE OF WALL
66260
JAYNOOL A. KHAYRATTEE
R E
E
O R
P
D
EE
R
S A
XETFOET
A
T S
NI
GNELANOIS
S E
F
RETSI
G
Matrix Structural Engineers TBPE Firm Registration No. F-2640
E N G I N E E R S
S T R U C T U R A L
M A T R I X
5177 RICHMOND AVE.
SUITE 670
HOUSTON, TEXAS 77056
PHONE: (713) 664-0130
FAX: (713) 664-1370
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
Drawing Number
DrawnChecked
Dwg. of 212 Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
MSE 14199
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
06.08.2018 AuthorChecker06/08/18
S-301
CONCRETE DETAILS CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON TX 77030
38Issued for Bidding & Construction 06/08/2018
1NO SCALE
2NO SCALE
3NO SCALE
4NO SCALE
5NO SCALE
6NO SCALE
7NO SCALE
8NO SCALE
9NO SCALE
10NO SCALE
11NO SCALE
12NO SCALE
13NO SCALE
14NO SCALE
15NO SCALE
TYPICAL DETAIL
STEEL BEAM TO COLUMN WEB
MOMENT CONNECTION
BACKING BAR
HIGH STRENGTH FRICTION
BOLTS TO DEVELOP
BEAM REACTION
SHOP WELD
TO DEVELOP
REACTION
SINGLE PLATE
FRAMING CONN.
NOTE:
1. BOLTS IN WEB CONNECTION SHALL BE TIGHTENED PRIOR
TO WELDING OF FLANGES.
TYPICAL DETAIL
STEEL BEAM TO COLUMN FLANGE
MOMENT CONNECTION
NOTES:
1. BOLTS IN WEB CONNECTION SHALL BE TIGHTENED PRIOR TO
WELDING OF FLANGES.
WIDTH OF STIFF.
PL. TO MATCH
COL. FLANGE
SHOP WELD
TO DEVELOP
REACTION
SINGLE PLATE
FRAMING CONN.
HIGH STRENGTH FRICTION
BOLTS TO DEVELOP
BEAM REACTION
BACKING BAR
2"
TYPICAL DETAIL
STEEL BEAM TO BEAM
MOMENT CONNECTION
BACKING BAR
HIGH STRENGTH FRICTION
BOLTS TO DEVELOP
BEAM REACTION
DOUBLE ANGLES
NOTES:
1. BOLTS IN WEB CONNECTION SHALL BE TIGHTENED PRIOR TO
WELDING OF FLANGES.
NOTES
1. BOLTS IN WEB CONNECTION SHALL BE TIGHTENED PRIOR TO
WELDING OF FLANGES.
HIGH STRENGTH FRICTION
BOLTS TO DEVELOP
BEAM REACTION
DOUBLE ANGLES
BACKING BAR
TYPICAL DETAIL
STEEL BEAM TO BEAM
MOMENT CONNECTION
TYPICAL DETAIL
STEEL BEAM TO WF COLUMN
DOUBLE ANGLE SHEAR CONNECTION
DOUBLE ANGLES
3/4" COLUMN CAP PLATE
(OMIT IF NO JOIST @ COLUMN LINE)
FIELD BOLTED
CONNECTION TO
DEVELOP BEAM
REACTION
COPE FLANGES IF REQUIRED
FOR ERECTION CLEARANCE
NOTES :
1. REFER TO GENERAL NOTES FOR BEAM REACTION DESIGN CRITERIA.
2. PROVIDE PRE-DESIGNED CONNECTIONS AS SHOWN IN AISC MANUAL
WHERE APPLICABLE.
3. REFER TO GENERAL NOTES FOR BOLT TYPE.
TYPICAL DETAIL
BEAM TO BEAM DOUBLE ANGLE
SHEAR CONNECTION
SHOP WELD CONN.
TO DEVELOP BEAM
REACTION. RE:
GENERAL NOTES
BLOCK AND REINFORCE BEAM
FOR BENDING AND SHEAR AS
REQUIRED TO SUPPORT REACTION
DOUBLE ANGLES
BOLTED CONNECTION
RE: GENERAL NOTES
NOTES :
1. REFER TO GENERAL NOTES FOR BEAM REACTION DESIGN CRITERIA.
2. PROVIDE PRE-DESIGNED CONNECTIONS AS SHOWN IN AISC MANUAL
PART 4 WHERE APPLICABLE.
3. REFER TO GENERAL NOTES FOR BOLT TYPE.
TYPICAL DETAIL
STEEL BEAM TO TUBE/PIPE - COL. CONNECTION
3/4" CAP PL.
3/8" STIFF. PL.
(BOTH SIDES)
PROVIDE FULL DEPTH
IF BM. FRAMING INTO IT.
3/4" CAP PL.
PROVIDE THRU
PLATE AT DIAG.
BRACES OR MOMENT
CONECTION ONLY, U.N.O.
3/8" STIFF. PL. (BOTH SIDES)
PROVIDE FULL DEPTH IF
BM. FRAMING INTO IT.
BEAM CONNECTING AT
BEAM AT ONE SIDE OF COLUMN
BOTH SIDES OF COL. OVER COLUMN
BEAM CANTILEVERING
A
B C
/2
(TYP.)
1 1/2"
(TYP.)
1 1/2"
SEE PLAN
/2
(TYP.)
1 1/2"
(TYP.)
1 1/2"
TYPICAL DETAIL
STUB COLUMN ON STEEL BEAM
3/8" FULL DEPTH
STIFF. PLATE
(BOTH SIDES)
3/16
3/16
1/4
1/4
3/4" BEARING
PL. W/ (4) - 3/4" DIA.
A325 BOLTS
BEAM, SEE PLAN
TS COL.
SEE PLAN
COL.
TYPICAL DETAIL
CANTILEVER BEAM
OVER COLUMN CONNECTION
3/16
3/4" CAP PL.
SEE PLAN
COLUMN,
STIFF. P (BOTH SIDES)
3/8" FULL DEPTH
3/16
3/16
11_
3" (TYP.) 3" (TYP.)
11_
TYP.
TYP.
SEE PLAN
CL. COL.
BOLTED WEB CONN.
DESIGN FOR REACTION
OF DROP IN BEAM
DROP-IN
BEAM
TYP.
L
NOTE:
1. JOISTS, METAL DECK AND BRACES NOT SHOWN FOR CLARITY.
SEE PLAN FOR BRACE LOCATIONS.
CL. COL.
66260
JAYNOOL A. KHAYRATTEE
R E
E
O R
P
D
EE
R
S A
XETFOET
A
T S
NI
GNELANOIS
S E
F
RETSI
G
Matrix Structural Engineers TBPE Firm Registration No. F-2640
E N G I N E E R S
S T R U C T U R A L
M A T R I X
5177 RICHMOND AVE.
SUITE 670
HOUSTON, TEXAS 77056
PHONE: (713) 664-0130
FAX: (713) 664-1370
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
Drawing Number
DrawnChecked
Dwg. of 212 Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
MSE 14199
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
06.08.2018
SHJK06/08/18
S-401
FRAMING DETAILS CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON TX 77030
39Issued for Bidding & Construction 06/08/2018
SEE PLAN
NEW EXISTING
1" EXP. JT.
RE: ARCH. FOR
ROOFING &
FLASHING DETAIL
R E
A
R C
H
/2
R O
O F
D E
C K
T.O.S.
BENT PLATE (1/4" THK.)
SEE PLAN
NEW EXISTING
1" EXP. JT.RE: ARCH. FOR
ROOFING &
FLASHING DETAIL
R E
A
R C
H
/2
R O
O F
D E
C K
T.O.S.
BENT PLATE (1/4" THK.)
SEE PLAN
NEW EXISTING
1" EXP. JT.
RE: ARCH. FOR
ROOFING &
FLASHING DETAIL
R E
A
R C
H
/2
R O
O F
D E
C K
T.O.S.
BENT PLATE (1/4" THK.)
2ND FLR. 74'-10"
1SCALE: 3/4" = 1'-0"
2SCALE: 3/4" = 1'-0"
3SCALE: 3/4" = 1'-0"5SCALE: 3/4" = 1'-0"
6SCALE: 3/4" = 1'-0"
7SCALE: 3/4" = 1'-0"
8SCALE: 3/4" = 1'-0"
9SCALE: 3/4" = 1'-0"
10SCALE: 3/4" = 1'-0"
4SCALE: 3/4" = 1'-0"
66260
JAYNOOL A. KHAYRATTEE
R E
E
O R
P
D
EE
R
S A
XETFOET
A
T S
NI
GNELANOIS
S E
F
RETSI
G
Matrix Structural Engineers TBPE Firm Registration No. F-2640
E N G I N E E R S
S T R U C T U R A L
M A T R I X
5177 RICHMOND AVE.
SUITE 670
HOUSTON, TEXAS 77056
PHONE: (713) 664-0130
FAX: (713) 664-1370
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
Drawing Number
DrawnChecked
Dwg. of 212 Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
MSE 14199
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
06.08.2018 AuthorChecker06/08/18
S-402
ROOF FRAMING DETAILS CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON TX 77030
40Issued for Bidding & Construction 06/08/2018