36C25619R0073-005.pdf
PDF Posted
- Attached to
- 580-320 Construct Spinal Cord Injury Expansion Federal contract opportunity
- Solicitation number
- 36C25619R0073
About this file
36C25619R0073 ATTACHMENT D - Project Drawings Part 1 - Dated 6-8-18 - 9 pages.pdf
View the file
Other files for this federal contract opportunity
Show all 50
580-320 Construct Spinal Cord Injury Expansion has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100-83 1G1H
100-84
1K 100-85
100-80 1D
100-79 1C
100-78 1B
100-77 1A
100-82 1F 1E
100-81
KEY PLAN
ADDITION
NP
L A
N N
O R
T H
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
Drawing Number
DrawnChecked
Dwg. of Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
V eterans Affairs P alo Alto Heal th Ca re Sy stem
S cale: 1 "= 20'-0"S cale: 1-1 /2"= 1'-0"S cale: 1"= 1'-0"S cale: 3/ 32"= 1'-0"S cale: 1/ 16"= 1'-0"S cale: 3/ 16"= 1'-0"S cale: 3/ 4"= 1'-0"S cale: 3/ 8"= 1'-0"S cale: 1/ 2"= 1'-0"S cale: 1/ 4"= 1'-0"
AV P AHC SV eterans Affairs P alo Alto Heal th Ca re Sy stem
D ESIGN DEVE LO PM ENT - NO T FO R CO NSTRUCTIO NF ULLY SPR INKL ERED
T exas Reg. No.G FE Project No.F-571213060
Issued for Bidding & Construction 06/08/18 212AuthorChecker06/08/18
GI-001
COVER SHEET CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON, TX 77030
#580 - 320
N
SHEET INDEX
GENERAL PROJECT NOTESFLOOR PLAN ISOMETRIC
MICHAEL E. DEBAKEY VA MEDICAL CENTER
LOCATION MAPSITE LOCATION
M A
IN
H A
R D
Y T
O L L R
O A
D
OST
HOLCOMBE
SITE
MICHAEL E. DEBAKEY VA MEDICAL CENTER
PROJECT
CONSTRUCT SPINAL CORD INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON, TX 77030
#580 - 320
SHEET INDEX
SHEET
# SHEET NAME
CURRENT
REVISION
PLUMBING
PL-000 PLUMBING INFORMATION SHEET
PL-001 PLUMBING SCHEDULES
PD-101 PLUMBING DEMO PLAN - BASEMENT UNDERFLOOR - AREA 1B
PD-102 PLUMBING DEMO PLAN - BASEMENT TUNNEL - AREA 1B
PD-103 PLUMBING & MED GAS DEMO PLAN - FIRST FLOOR - AREA 1B
PD-104 PLUMBING DEMO PLAN - FIRST FLOOR INTERSTITIAL - AREA
1B
PD-105 MED GAS DEMO PLAN - FIRST FLOOR INTERSTITIAL - AREA 1B
PD-106 PLUMBING DEMO PLAN - BASEMENT - ADDITION
PD-107 PLUMBING DEMO PLAN - ADDITION
PD-108 PLUMBING DEMO PLAN - BASEMENT UNDEFLOOR - AREA 1A
PD-109 PLUMBING DEMO PLAN - BASEMENT TUNNEL - AREA 1A
PD-110 PLUMBING & MED GAS DEMO PLAN - FIRST FLOOR - AREA 1A
PD-111 PLUMBING DEMO PLAN - FIRST FLOOR INTERSTITIAL - AREA
1A
PD-112 MED GAS DEMO PLAN - FIRST FLOOR INTERSTITIAL - AREA 1A
PL-101 PLUMBING PLAN - BASEMENT UNDERFLOOR - AREA 1B
PL-102 PLUMBING PLAN - BASEMENT TUNNEL - AREA 1B
PL-103 PLUMBING & MED GAS & FIRE PROTECTION PLAN - FIRST
FLOOR - AREA 1B
PL-104 PLUMBING PLAN - FIRST FLOOR INTERSTITIAL - AREA 1B
PL-105 MED GAS PLAN - FIRST FLOOR INTERSTITIAL - AREA 1B
PL-106 PLUMBING PLAN - BASEMENT - ADDITION
PL-107 PLUMBING PLAN - FIRST FLOOR - ADDITION
PL-108 MED GAS & FIRE PROTECTION PLAN - FIRST FLOOR -
ADDITION
PL-109 PLUMBING ROOF PLAN - ADDITION
PL-110 PLUMBING PLAN - BASEMENTUNDERFLOOR -AREA 1A
PL-111 PLUMBING PLAN - BASEMENT TUNNEL - AREA 1A
PL-112 PLUMBING & MED GAS & FIRE PROTECTION PLAN - FIRST
FLOOR - AREA 1A
PL-113 PLUMBING PLAN - FIRST FLOOR INTERSTITIAL - AREA 1A
PL-114 MED GAS PLAN - FIRST FLOOR INTERSTITIAL - AREA 1A
PL-201 DETAILS – PLUMBING
PL-301 RISERS - PLUMBING
TELECOMMUNICATIONS
TS-000 TECHNOLOGY - INFORMATION SHEET
TD-101 TECHNOLOGY DEMO PLAN - FIRST FLOOR - AREA 1B
TD-102 TECHNOLOGY DEMO PLAN - FIRST FLOOR - ADDITION
TD-103 TECHNOLOGY DEMO PLAN - FIRST FLOOR - AREA 1A
TS-101 TECHNOLOGY PLAN - FIRST FLOOR - AREA 1B
TS-102 TECHNOLOGY PLAN - FIRST FLOOR - ADDITION
TS-103 TECHNOLOGY PLAN - FIRST FLOOR - AREA 1A
TS-200 TECHNOLOGY - DETAIL SHEET
SHEET INDEX
SHEET
# SHEET NAME
CURRENT
REVISION
AE-412 ENLARGED REFLECTED CEILING PLANS
AE-413 ENLARGED REFLECTED CEILING PLANS
AE-414 ENLARGED REFLECTED CEILING PLANS
AE-415 ENLARGED REFLECTED CEILING PLANS
AE-431 ENLARGED EQUIPMENT PLANS
AE-432 ENLARGED EQUIPMENT PLANS
AE-501 PLAN DETAILS
AE-502 PLAN DETAILS
AE-503 PLAN DETAILS
AE-511 EXTERIOR AND ROOF DETAILS
AE-512 EXTERIOR AND ROOF DETAILS
AE-521 INTERIOR DETAILS
AE-541 DOOR, WINDOW AND LOUVER DETAILS
AE-542 DOOR, WINDOW AND LOUVER DETAILS
AE-561 MISCELLANEOUS DETAILS
AE-562 MISCELLANEOUS DETAILS
AE-563 MISCELLANEOUS DETAILS
AE-564 MISCELLANEOUS DETAILS
AE-565 MISCELLANEOUS DETAILS
AE-566 MISCELLANEOUS DETAILS
AE-571 MILLWORK DETAILS
AE-572 MILLWORK DETAILS
AE-573 MILLWORK DETAILS
AE-602 PARTITION TYPES
AE-611 DOOR AND WINDOW SCHEDULES
AE-621 FINISH SCHEDULE
AE-631 ACCESSORY SCHEDULE
AE-632 ACCESSORY SCHEDULE
AE-633 ACCESSORY SCHEDULE
INTERIOR
IN-101 FINISH FLOOR PLAN - FIRST FLOOR - AREA 1B
IN-102 FINISH FLOOR PLAN - FIRST FLOOR - ADDITION
IN-103 FINISH FLOOR PLAN - FIRST FLOOR - AREA 1A
IN-111 WALL PROTECTION PLAN - FIRST FLOOR - AREA 1B
IN-112 WALL PROTECTION PLAN - FIRST FLOOR - ADDITION
IN-113 WALL PROTECTION PLAN - FIRST FLOOR - AREA 1A
IN-121 INTERIOR SIGNAGE PLAN - FIRST FLOOR - AREA 1B
IN-122 INTERIOR SIGNAGE PLAN - FIRST FLOOR - ADDITION
IN-123 INTERIOR SIGNAGE PLAN - FIRST FLOOR - AREA 1A
MECHANICAL
MH-000 MECHANICAL - INFORMATION SHEET
MH-001 MECHANICAL - SCHEDULES
MH-002 MECHANICAL - SCHEDULES
MD-101 MECHANICAL DEMO PLAN - FIRST FLOOR - AREA 1B
MD-102 MECHANICAL DEMO PLAN - FIRST FLOOR INTERSTITIAL - AREA
1B
MD-103 MECHANICAL DEMO PLAN - FIRST FLOOR - AREA 1A
MD-104 MECHANICAL DEMO PLAN - FIRST FLOOR INTERSTITIAL - AREA
1A
MD-105 MECHANICAL DEMO PIPING PLAN - FIRST FLOOR
INTERSTITIAL - AREA 1B
MD-106 MECHANICAL DEMO PIPING PLAN - FIRST FLOOR
INTERSTITIAL - AREA 1A
MH-101 MECHANICAL PLAN - FIRST FLOOR - AREA 1B
MH-102 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL - AREA 1B
MH-103 MECHANICAL PLAN - FIRST FLOOR - AREA 1A
MH-104 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL - AREA 1A
MH-105 MECHANICAL PLAN - FIRST FLOOR - ADDITION
MH-201 MECHANICAL PIPING PLAN - FIRST FLOOR INTERSTITIAL -
AREA 1B
MH-202 MECHANICAL PIPING PLAN - FIRST FLOOR INTERSTITIAL -
AREA 1A
MH-203 MECHANICAL PIPING PLAN - FIRST FLOOR - ADDITION
MH-301 MECHANICAL ENLARGED PLAN - FIRST FLOOR - AREA 1B
MH-302 MECHANICAL ENLARGED PLAN - FIRST FLOOR - AREA 1A
MH-303 MECHANICAL ENLARGED PLAN - FIRST FLOOR - ADDITION
MH-304 MECHANICAL ENLARGED PLAN - SIXTH FLOOR - AREA 6B
MH-401 MECHANICAL PHASING PLAN - AREA 1B - PHASE 1A - 1 AND 2
MH-402 MECHANICAL PHASING PLAN - AREA 1B - PHASE 1A - 3
MH-403 MECHANICAL PHASING PLAN - AREA 1B - PHASE 1A - 4
MH-404 MECHANICAL PHASING PLAN - AREA 1A - PHASE 2 - 1 AND 2
MH-405 MECHANICAL PHASING PLAN - AREA 1A - PHASE 2 - 3
MH-406 MECHANICAL PHASING PLAN - AREA 1A - PHASE 2 - 4
MH-501 MECHANICAL DETAILS
MH-502 MECHANICAL DETAILS
MH-503 MECHANICAL DETAILS
MH-601 MECHANICAL CONTROLS - SEQUENCE OF OPERATIONS
MH-602 MECHANICAL CONTROLS - SEQUENCE OF OPERATIONS
ELECTRICAL
ES-000 ELECTRICAL - INFORMATION SHEET
ES-001 ELECTRICAL - ONE-LINE RISER DIAGRAM
ES-002 ELECTRICAL - PANEL SCHEDULES
ES-003 ELECTRICAL - PANEL SCHEDULES
ES-004 ELECTRICAL - PANEL SCHEDULES
ED-101 ELECTRICAL DEMOTLITION PLAN - FIRST FLOOR - AREA 1B
ED-102 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR - ADDITION
ED-103 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR - AREA 1A
ES-101 LIGHTING PLAN - FIRST FLOOR - AREA 1B
ES-102 LIGHTING PLAN - FIRST FLOOR - ADDITION
ES-103 LIGHTING PLAN - FIRST FLOOR - AREA 1A
ES-201 POWER PLAN - FIRST FLOOR - AREA 1B
ES-202 POWER PLAN - FIRST FLOOR - ADDITION
ES-203 POWER PLAN - FIRST FLOOR - AREA 1A
ES-301 EQUIPMENT POWER PLAN - FIRST FLOOR - AREA 1B
ES-302 EQUIPMENT POWER PLAN - FIRST FLOOR - ADDITION
ES-303 EQUIPMENT POWER PLAN - FIRST FLOOR - AREA 1A
ES-401 DETAILS - ELECTRICAL
SHEET INDEX
SHEET
# SHEET NAME
CURRENT
REVISION
GENERAL
GI-001 COVER SHEET
GI-011 LIFE SAFETY PLAN
GI-021 ACCESSIBLITY & MOUNTING HEIGHTS
GI-031 UL ASSEMBLIES
GI-032 UL ASSEMBLIES
GI-033 UL ASSEMBLIES
GI-034 UL ASSEMBLIES
GI-035 UL ASSEMBLIES
GI-111 SPACE PROGRAM REQUIREMENTS
GI-121 FIRST FLOOR - CONSTRUCTION PHASING PLAN
GI-122 FIRST FLOOR - CONSTRUCTION PHASING PLAN
GI-123 FIRST FLOOR - CONSTRUCTION PHASING PLAN
GI-124 FIRST FLOOR - CONSTRUCTION PHASING PLAN
GI-125 FIRST FLOOR - CONSTRUCTION PHASING PLAN
GI-130 DESIGN ALTERNATES - ARCHITECTURE
GI-140 DESIGN ALTERNATES - MECHANICAL
GI-141 MECHANICAL DEMO PLAN - BID DEDUCT 1 AND 2
GI-142 MECHANICAL DEMO PLAN -BID DEDUCT 1 AND 2 -
INTERSTITIAL
GI-143 MECHANICAL DEMO PIPING PLAN - BID DEDUCT 1 AND 2 -
INTERSTITIAL
GI-144 MECHANICAL PLAN - FIRST FLOOR - BID DEDUCT 1 AND 2
GI-145 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL - BID
DEDUCT 1 AND 2
GI-146 MECHANICAL PIPING PLAN - FIRST FLOOR INTERSTITIAL - BID
DEDUCT 1 AND 2
GI-147 MECHANICAL DEMO PLAN - BID DEDUCT 3
GI-148 MECHANICAL DEMO PLAN - BID DEDUCT 3 - INTERSTITIAL
GI-149 MECHANICAL DEMO PIPING PLAN - BID DEDUCT 3 -
INTERSTITIAL
GI-150 MECHANICAL PLAN - FIRST FLOOR - BID DEDUCT 3
GI-151 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL - BID
DEDUCT 3
GI-152 MECHANICAL PIPING PLAN - FIRST FLOOR INTERSTITIAL - BID
DEDUCT 3
GI-160 DESIGN ALTERNATES - ELECTRICAL
GI-170 DESIGN ALTERNATES - PLUMBING
GI-180 DESIGN ALTERNATES - TECHNOLOGY
GI-201 AS BUILT INFORMATION - PLANS
GI-202 AS BUILT INFORMATION - PLANS
GI-211 AS BUILT INFORMATION - DETAILS
GI-212 AS BUILT INFORMATION - DETAILS
STRUCTURAL
S-001 GENERAL NOTES
S-201 ADDITIONAL FRAMING PLAN
S-301 CONCRETE DETAILS
S-401 FRAMING DETAILS
S-402 ROOF FRAMING DETAILS
ARCHITECTURAL DEMOLITION
AD-100 DEMOLITION PLAN - FIRST FLOOR - OVERALL
AD-101 DEMOLITION PLAN - FIRST FLOOR - AREA 1B
AD-102 DEMOLITION PLAN - FUTURE ADDITION AREA
AD-103 DEMOLITION PLAN - FIRST FLOOR - AREA 1A
AD-110 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR -
OVERALL
AD-111 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR - AREA
1B
AD-112 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR - AREA
1A
AD-201 DEMOLITION EXTERIOR ELEVATIONS
AD-202 DEMOLITION EXTERIOR ELEVATIONS
ARCHITECTURAL
AE-101 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 1 - NOTES
AE-102 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 1 ADDITION -
NOTES
AE-103 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 2 - NOTES
AE-104 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 3 - NOTES
AE-105 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 4 - NOTES
AE-111 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 1 -
DIMENSIONS
AE-112 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 1 ADDITION -
DIMENSIONS
AE-113 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 2 -
DIMENSIONS
AE-114 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 3 -
DIMENSIONS
AE-115 ARCHITECTURAL PLAN - FIRST FLOOR - PHASE 4 -
DIMENSIONS
AE-121 REFLECTED CEILING PLAN - FIRST FLOOR - PHASE 1
AE-122 REFLECTED CEILING PLAN - FIRST FLOOR - PHASE 1 ADDITION
AE-123 REFLECTED CEILING PLAN - FIRST FLOOR - PHASE 2
AE-124 REFLECTED CEILING PLAN - FIRST FLOOR - PHASE 3
AE-125 REFLECTED CEILING PLAN - FIRST FLOOR - PHASE 4
AE-141 ROOF PLAN - ADDITION
AE-150 EQUIPMENT PLAN - FIRST FLOOR - OVERALL
AE-151 EQUIPMENT PLAN - FIRST FLOOR - AREA 1B
AE-152 EQUIPMENT PLAN - FIRST FLOOR - ADDITION
AE-153 EQUIPMENT PLAN - FIRST FLOOR - AREA 1A
AE-201 EXTERIOR ELEVATIONS
AE-211 INTERIOR ELEVATIONS
AE-212 INTERIOR ELEVATIONS
AE-213 INTERIOR ELEVATIONS
AE-214 INTERIOR ELEVATIONS
AE-221 INTERIOR ELEVATIONS - ENLARGED
AE-222 INTERIOR ELEVATIONS - ENLARGED
AE-301 BUILDING SECTION
AE-302 BUILDING SECTION
AE-311 WALL SECTIONS
AE-312 WALL SECTIONS
AE-401 ENLARGED ARCHITECTURAL PLANS
AE-402 ENLARGED ARCHITECTURAL PLANS
AE-403 ENLARGED ARCHITECTURAL PLANS
AE-404 ENLARGED ARCHITECTURAL PLANS
AE-405 ENLARGED ARCHITECTURAL PLANS
AE-411 ENLARGED REFLECTED CEILING PLANS
PROJECT LOCATION
1. THE WORK SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES, LAWS AND ORDINANCES
INCLUDING THE SEPTEMBER 15, 2010 ARCHITECTURAL BARRIERS ACT(ABA) AND W/ VA SUPPLEMENTS.
2. THE WORK SHALL COMPLY WITH OR EXCEED ALL THE DEPARTMENT OF VETERANS AFFAIRS (VA)
BUILDING STANDARDS.
3. WHERE THE TERM "APPROVED" OR "EQUAL" IS USED, IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE TO THE RULING AND JUDGMENT OF THE VA COR AND THE PROPOSED SUBSTITUTION SHALL BE
SUBMITTED FOR REVIEW AND WRITTEN APPROVAL.
4. MAINTAIN ALL EXIT PATHS FOR THE DURATION OF THE CONSTRUCTION. ERECT AND MAINTAIN APPROPRIATE SAFETY BARRIERS AND PATHWAYS TO PROTECT AND SEPARATE PUBLIC/STAFF FROM HAZARDOUS CONDITIONS. BARRIERS SHALL BE MAINTAINED THROUGH DURATION OF THE PROJECT TO
PROHIBIT UNAUTHORIZED PERSONNEL FROM ENTERING THE CONSTRUCTION AREA/SITE.
5. REFER TO THE DRAWINGS & PROJECT MANUAL FOR ANY REQUIRED PROJECT PHASING AND OPTIONS.
6. CONTRACTOR SHALL PARK IN DESIGNATED LOCATIONS REQUIRED BY THE VA. CONSTRUCTION TRAILER, IF ANY, SHALL BE LOCATED WHERE DETERMINED BY THE VA IF SPACE IS AVAILABLE. THE GENERAL CONTRACTOR SHALL COORDINATE ACCESS TO/AND STORAGE ON SITE WITH THE VA. THE GENERAL
CONTRACTOR SHALL ALSO REPAIR DAMAGE TO ALL ADJACENT AREAS OCCURRING DUE TO
CONSTRUCTION.
7. CONTRACTOR SHALL ERECT AND MAINTAIN IN A SECURE MANNER, CONSTRUCTION PARTITIONS, FENCES & BARRICADES AROUND CONSTRUCTION SITE & STORAGE AREAS DESIGNATED BY THE VA.
8. ERECT DUST AND/ OR TEMPORARY PARTITIONS REQUIRED BY VA COR PRIOR TO COMMENCEMENT OF WORK AND MAINTAIN FOR DURATION OF CONSTRUCTION. REPAIR ALL FINISHES DAMAGED BY THE PARTITION INSTALLATION AT THE TIME THE PARTITION IS REMOVED. PROVIDE TEMPORARY GUARDRAILS AT
ALL TIMES, AT ALL FLOOR LEVEL EDGES AND OPENINGS.
9. SCHEDULE ALL ELECTRICAL POWER, PLUMBING, SECURITY, MECHANICAL, COMMUNICATION & FIRE
ALARM OUTAGES WITH VA COR GIVING REQUIRED ADVANCED NOTICE PRIOR TO OUTAGE.
10. PROTECT ALL WORK SCHEDULED TO REMAIN FOR DURATION OF CONSTRUCTION.
CONTRACTOR TO PROVIDE AND ERECT VISUAL AND PHYSICAL BARRIERS AROUND EACH AREA OF WELDING
OPERATIONS, IF ANY, AND FOLLOW VA REQUIRED PROCEDURES.
11. REMOVE TRASH AND DEBRIS AT THE END OF EACH WORK DAY, DISPOSE OF IN A LEGAL MANNER.
12. FLOOR SURFACE TO BE PATCHED AND PREPARED FOR SCHEDULED FINISHES, PRIOR TO INSTALLATION OF ALL FLOOR FINISHES. VOIDS TO BE FILLED WITH LEVELING COMPOUND FORMULATED FOR EXTERIOR USE.
13. PROVIDE REQUIRED FIRE-RATED FIRE STOPPING AROUND ALL PENETRATIONS TO FLOOR ABOVE OR
BELOW.
14. DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF THE VA AND THE ARCHITECT AND MAY NOT BE REPRODUCED IN ANY MANNER WITHOUT EXPRESSED WRITTEN CONSENT. CONTRACTOR SHALL NOT REPRODUCE ANY PORTION OF A CONTRACT DRAWING FOR USE IN ANY PORTION OF A
SUBMITTAL.
15. ALL SUBSTITUTIONS AND CHANGES TO THESE DRAWINGS MUST BE SUBMITTED TO THE VA .
16. THE GENERAL CONTRACTOR SHALL INVESTIGATE ALL FIELD CONDITIONS RELEVANT TO THE PROJECT INCLUDING, BUT NOT LIMITED TO, DIMENSIONS, ELEVATIONS, GENERAL CONDITIONS AND OTHER MISCELLANEOUS EXISTING CONDITIONS AND SHALL PROMPTLY NOTIFY THE VA OF ANY WHICH DO NOT
AGREE WITH THOSE IN THESE DRAWINGS.
17. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING AND INSTALLING ALL COMPONENTS AND ACCESSORIES, EQUIPMENT, MATERIALS, HARDWARE AND OTHER ITEMS NECESSARY (UNLESS NOTED OTHERWISE) FOR A COMPLETE AND FINISHED JOB CONSISTENT WITH THE DESIGN INTENT PRESENTED IN THESE DRAWINGS. COORDINATE THE LOCATION AND INSTALLATION OF ALL MECHANICAL AND ELECTRICAL
DEVICES, REGISTERS, FIXTURES, ETC. PRIOR TO INSTALLATION OF FINISH MATERIALS.
18. EXISTING SYSTEMS AND SERVICES PASSING THROUGH CONSTRUCTION AREAS AND SERVING OCCUPIED AREAS ARE TO REMAIN OPERATIONAL. EXISTING SYSTEMS PASSING THROUGH NON CONSTRUCTION AREAS THAT REQUIRE ALTERATION ARE TO BE SCHEDULED WITH THE VA-COR TO MINIMIZE DISRUPTION OF
OCCUPIED AREAS AND ONGOING OPERATIONS.
19. REFER TO PROJECT MANUAL AND MEP DRAWINGS FOR ADDITIONAL REQUIREMENTS.
20. COORDINATE WITH VA PRIOR TO COMMENCING WORK PROJECT ACCESS ROUTE, ALLOWABLE WORK
TIMES, ALLOWABLE NOISE LEVELS, TOILET TO BE USED BY WORKERS, ETC.
21. PRIOR TO THE START OF ANY WORK ON THE PROJECT, A PRE-CONSTRUCTION RISK ASSESSMENT, WHICH INCLUDES AN INTERIM LIFE SAFETY EVALUATION, MUST BE COMPLETED, DOCUMENTED AND SIGNED
BY VA ENVIRONMENTAL HEALTH AND SAFETY, VA PROJECT MANAGER AND THE CONTRACTOR.
22. MAINTENANCE OF INDOOR AIR QUALITY IS CRITICAL IN AREAS OF ALL FACILITIES. CONSTRUCTION CAUSING DISTURBANCE OF EXISTING DUST, OR CREATING NEW DUST, ODORS, ETC. MUST BE CONDUCTED IN TIGHT ENCLOSURES THAT PROHIBIT THE FLOW OF PARTICLES INTO SENSITIVE AREAS. THE CONTRACTOR IS REQUIRED TO PROVIDE DUST BARRIERS AS DETERMINED BY THE VA COR, ENVIRONMENTAL HEALTH AND SAFETY AND/OR INFECTION CONTROL. THIS PROJECT SHALL BE CONSIDERED TO BE CLASS III/IAQ CONSTRUCTION AS REFERENCED IN THE VA POLICY/PROCEDURE FOR MAINTAINING INDOOR AIR QUALITY DURING CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL ADDITIONALLY COMPLY WITH KEYED
NOTES/GENERAL NOTES CONTAINED ON THE DRAWINGS WHERE THEY EXCEED THE STANDARD
REQUIREMENTS OF CLASS III/IAQ CONSTRUCTION.
23. THE VA RETAINS THE PRIMARY RESPONSIBILITY FOR THE PRESENCE, CONDITION, DISTURBANCE, RENOVATION, DEMOLITION, AND DISPOSAL OF ANY ASBESTOS ENCOUNTERED IN THE CONSTRUCTION, OPERATIONS, MAINTENANCE, OR FURNISHING OF THE FACILITIES ASSOCIATED WITH THE WORK HEREIN. DO NOT COMMENCE ANY WORK ASSOCIATED WITH THIS PROJECT UNTIL APPROVED TO DO SO BY FACILITIES
AND EHS. COORDINATE APPROVAL THROUGH VA COR.
24. "OWNER" & "VA" ARE TERMS USED INTERCHANGIBLY IN SET. IN ALL CASES COORDINATE THROUGH VA-
COR
PHASE 1 PHASE 1
PHASE 4
PHASE 2
PHASE 3
P L A
N N
T R
U E
N
PLA
N N
A T
PATIE
N T U
N
IT
S
F.E.C.
F.E.C.
F .E
.C
F.E.C.F.E.C.
F.E .C
F.E .C
F .E
.C
F.E .C
F.E.C.
F.E.C.
F.E.C
F.E.C
F.E.C
F.E.C.
F.E .C
F .E
.C
F .E
.C
F .E
.C
SMOKE PARTITION - EXISTING
2 HOUR FIRE RESISTIVE/SMOKE BARRIER
1 HOUR FIRE RESISTIVE PARTITION
1 HOUR FIRE RESISTIVE/SMOKE BARRIER
2 HOUR FIRE RESISTIVE PARTITION
FIRE EXTINGUISHER CABINET (SEMI RECESSED)
EGRESS
TRAVEL
DISTANCE
1A SMOKE COMPARTMENT
1B SMOKE COMPARTMENT
HAZARDOUS AREA 1-HR FIRE RESISTIVE CONSTRUCTION
CLINIC ADDITION SMOKE COMPARTMENT
LIFE SAFETY / CODE LEGEND
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT EXITEXITEXIT
EGRESS TRAVEL DIST. =169'-8"
MAX TRAVEL DIST. =200'-0"
EGRESS TRAVEL DIST. =199'-4"
MAX TRAVEL DIST. =200'-0"
STAIR
STAIR
STAIR
STAIR
COURTYARD
ELEVATORS
ELEVATORS
ELEVATORS
ELEVATORS
EXISTING EXIT
THROUGH
BASEMENT
LEVEL
PR
O
JE
C T L
IM
IT
S
PR
O
JE
C T L
IM
IT
S
PR
O
JEC
T LIM
ITS
PR
O
JEC
T LIM
ITS
P R
O J E
C T
L
IM
IT
S
P R
O J E
C T
L
IM
IT
S
EXISTING EXIT
THROUGH
BASEMENT
LEVEL
NEW 2 HOUR FIRE SMOKE BARRIER
EXTEND TO UNDERSIDE OF
INTERSTITIAL
NOTE: EGRESS TRAVEL DISTANCE TO EXISTING EXIT
SEPARATION EXCEEDS ALLOWABLE TRAVEL DISTANCE.
PROJECT INCLUDES CONSTRUCTION OF NEW PROJECT
INCLUDES CONSTRUCTION OF NEW 2-HR FIRE
SEPARATION TO REDUCE THE TRAVEL DISTANCE TO
WITHIN ALLOWABLE LIMITS
2-HR FIRE/SMOKE SEPARATION UTILIZES EXISTING CONCRETE WALL PANELS AS
BARRIER ELEMENTS WITH 2-HR PARTITION CONSTRUCTION AT OPENINGS. PARTITION
CONSTRUCTION TO BE ERECTED AT CONSTRUCTION ONSET TO PROVIDE SEPARATION
DURING CONSTRUCTION.
NEW 2 HOUR
FIRE BARRIER
NOTE: 2-HR FIRE/SMOKE BARRIER TO BE
ERECTED AT CONSTRUCTION ONSET TO
PROVIDE SEPARATION OF CONSTRUCTION
AREAS DURING CONSTRUCTION.
CLINIC
ADDITION
77 FT TRAVEL TO
2-HR FIRE/SMOKE
SEPARATION
65 FT TRAVEL TO
2-HR FIRE/SMOKE
SEPARATION
94 FT TRAVEL TO 2-HR
FIRE/SMOKE SEPARATION
A/E SUBMISSION INSTRUCTIONS FOR MINOR AND NRM CONSTRUCTION PROGRAM: VA PROGRAM GUIDE, PG-18-15, VOLUME C
NOV 2008
2009 INTERNATIONAL EXISTING BUILDING CODE
2009 INTERNATIONAL BUILDING CODE (IBC)
2009 INTERNATIONAL MECHANICAL CODE (IMC)
2009 UNIFORM PLUMBING CODE (UPC)
2011 NATIONAL ELECTRIC CODE (NFPA-70)
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2013 EDITION
NFPA 72, NATIONAL FIRE ALARM CODE, 2013 EDITION
NFPA 99, STANDARD FOR HEALTH CARE FACILITIES, 2012 EDITION
2012 NFPA 101, LIFE SAFETY CODE
VA FIRE PROTECTION MANUALS
ASHRAE GUIDELINES AND STANDARDS 90.1, 2013 EDITION
THE ARCHITECTURAL BARRIERS ACT(ABA) AS OF SEPT 15, 2010 WITH VA SUPPLEMENTS
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)
2010 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND HEALTH CARE FACILITIES-AIA
ASSOCIATED AIR BALANCING COUNCIL STANDARDS (AABC)
UNDERWRITERS' LABORATORIES STANDARDS
ILLUMINATING ENGINEERING SOCIETY STANDARDS
GUIDELINES FOR ENVIRONMENTAL INFECTION CONTROL IN HEALTH CARE FACILITIES (CDC)
JOINT COMMISSION ACCREDITATION MANUAL FOR HOSPITALS, ENVIRONMENT OF CARE STANDARDS
APPLICABLE CODES
PROJECT NAME: DEBAKEY VAMC, SPINAL CORD
PROJECT ADDRESS: MICHAEL E, DEBAKEY VA MEDICAL CENTER
2002 HOLCOMBE BLVD,
HOUSTON, TX 77030
JURISDICTION: FEDERAL GOVERNMENT
DESCRIPTION:
PROJECT SCOPE OF WORK CONSIST OF THE RENOVATION AND EXPANSION OF THE SPINAL CORD INJURY UNIT (SCI) LOCATED IN THE FIRST FLOOR (BUILDING 100) OF THE MICHAEL E. DEBAKEY VA MEDICAL CENTER IN HOUSTON, TEXAS. THE PROJECT WILL CONVERT EXISTING 4-BED ROOM TO 2-BED ROOMS. THE PROJECT WILL ALSO CONSTRUCT AN EXPANSION OF THE SCI UNIT WITHIN THE EXISTING COURTYARD SPACE. THE TOTAL PROJECT AREA IS APPROXIMATELY 24,171 SF. THE NEW RENOVATION SHALL COMPLY WITH VA HOSPITAL STANDARDS. THE SCOPE OF WORK INCLUDES AND NEW TEMPORARY CONSTRUCTION OF NON-LOAD BEARING PARTITIONS, REMODEL MECHANICAL, ELECTRICAL, AND PLUMBING WORK, AND NEW
FINISHES.
PROJECT AREA
AREA 1A (RENOVATION): 7,761
AREA 1B (RENOVATION): 8,527
TOTAL RENOVEATED AREA: 16,288 SF
CLINIC (NEW CONSTRUCTION): 6,217 SF
CLINIC (EXTERIOR): 1,604 SF
TOTAL PROJECT AREA: 24,109 SF
PROJECT INFORMATION
OCCUPANCY CLASSIFICATION: I-2 (IBC)
EXISTING HEALTHCARE (NFPA)
CONSTRUCTION TYPE: EXISTING BUILDING - NFPA TYPE II
FIRE PROTECTION SYSTEM: AUTOMATIC
FIRE PROTECTION RATINGS: STRUCTURE - 2 HOURS
FRAME (ROOF) - 2 HOURS
ROOF ASSEMBLY - 1 1/2 HOURS
OCCUPANCY EGRESS ANALYSIS: PER LIFE SAFETY PLAN ON THIS SHEET
MEANS OF EGRESS REQUIREMENTS:
DEAD-END CORRIDORS SHALL NOT EXCEED 50 FT PER NFPA 101 38.2.5.2.1 - EXISTING EXIT
COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FT PER NFPA 101 38.2.5.3.1 - EXISTING EXIT
TRAVEL DISTANCE SHALL NOT EXCEED 200 FT PER NFPA 101 21.2.6.2 - EXISTING EXIT
NOTE: 2-HR FIRE/SMOKE SEPARATION PROVIDED TO MAINTAIN COMPLIANCE
FOR MAXIMUM TRAVEL DISTANCE TO EXIT.
HAZARDOUS AREA:
HAZARDOUS AREAS INCLUDING, BUT NOT LIMITED TO , AREAS USED FOR GENERAL STORAGE, BOILER OR FURNACE ROOMS, AND MAINTENANCE SHOPS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 8.7 PER NFPA 101 38.3.2.1
WHICH REQUIRES A 1 HOUR FIRE RESISTIVE CONSTRUCTION
STORAGE OF QUANTITIES GREATER THAN 5 GAL IN A SINGLE SMOKE COMPARTMENT SHALL MEET THE
REQUIREMENTS OF NFPA30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODES.
MEDICAL GAS:
SEPARATE OXYGEN CYLINDER STORAGE WITH 1 HOUR FIRE RESISTIVE CONSTRUCTION PER NFPA 101 18.3.2.4 &
NFPA 99
CORRIDORS:
CORRIDOR FIRE RESISTANCE RATING: 0 HR AS EXISTING BUILDING HAS APPROVED SPRINKLER SYSTEM IN
ACCORDANCE \WITH NFPA 101 9.7.1.1(1)
CORRIDOR SEPARATION TO BE CONSTRUCTED AS A SMOKE PARTITION PER IBC 407.3, IBC 711, NFPA 101 18.3.6
SUBDIVISION OF BUILDING SPACES:
MAXIMUM SIZE OF SMOKE COMPARTMENT: 22,500 SF
EXISTING SMOKE COMPARTMENT AREA 1A: 19,096 SF (BASED ON EXISTING DOCUMENTATION, TO BE VERIFIED) EXISTING SMOKE COMPARTMENT AREA 1B: 22,299 SF (BASED ON EXISTING DOCUMENTATION, TO BE VERIFIED)
SMOKE COMPARTMENT - CLINIC ADDITION: 6,163SF
NOTE ALL FIRE-RESISTANT CONSTRUCTION TO BE OF TYPE X GYPSUM BOARD, UNLESS NOTED OTHERWISE
PLUMBING FIXTURES: (TABLE 2902.1 FOR "I-2" OCCUPANCY)
OCCUPANCY LOAD
CLINIC ADDITION "I-2" OCCUPANCY 6,163.95 SF/240 SF/OCC = 26 OCCUPANTS
INPATIENT/OUTPATIENT (INPATIENT ONLY) / 6163/100 = 62 (OUTPATIENT ONLY)
CODE ANALYSIS
100-83 1G1H
100-84
1K 100-85
100-80 1D
100-79 1C
100-78 1B
100-77 1A
100-82 1F 1E
100-81
N
SMOKE COMPARTMENT KEY PLAN
ADDITION
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
Drawing Number
DrawnChecked
Dwg. of Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
V eterans Affairs P alo Alto Heal th Ca re Sy stem
S cale: 1 "= 20'-0"S cale: 1-1 /2"= 1'-0"S cale: 1"= 1'-0"S cale: 3/ 32"= 1'-0"S cale: 1/ 16"= 1'-0"S cale: 3/ 16"= 1'-0"S cale: 3/ 4"= 1'-0"S cale: 3/ 8"= 1'-0"S cale: 1/ 2"= 1'-0"S cale: 1/ 4"= 1'-0"
AV P AHC SV eterans Affairs P alo Alto Heal th Ca re Sy stem
D ESIGN DEVE LO PM ENT - NO T FO R CO NSTRUCTIO NF ULLY SPR INKL ERED
T exas Reg. No.G FE Project No.F-571213060
Issued for Bidding & Construction 06/08/18 212AuthorChecker06/08/18
GI-011
LIFE SAFETY PLAN CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON, TX 77030
#580 - 320
0' 16' 24'8'4' 1/16" = 1'-0"
FIRST FLOOR - LIFE SAFETY PLAN
F1
FIXTURE TYPE REQUIREMENT
FIXTURES
PROVIDED REQUIREMENT
FIXTURES
PROVIDED
WATER CLOSETS
- PATIENT ROOM/EXAM 1/ROOM 1/ROOM 1 1
- STAFF 1/25 EXISTING 1 1
- VISITORS 1/75 EXISTING 1 1
LAVATORIES
- PATIENT ROOM/EXAM 1/ROOM 1/ROOM 1 1
- STAFF 1/35 EXISTING 1 1
- VISITORS 1/100 EXISTING 1 1
BATHTUBS/ SHOWERS
- PATIENT ROOM 1/15 1/ROOM N/A
- STAFF 0 1/ROOM N/A
- VISITORS 0 1/ROOM N/A
SERVICE SINK 1 EXISTING 1 1
DRINKING FOUNTAIN SHARED W/
HOSPITAL
- PATIENT ROOM 1/100 EXISTING
- STAFF 1/100 EXISTING
- VISITORS 1/500 EXISTING
INPATIENT CLINIC - OUTPATIENT 62 PPL
OCCUPANT LOAD
D E
S K
I N
T E
R C
O M
O U
T L E
T
D U
P L E
X E
L E
C T
R
IC
A L O
U T
L E
T
E O
T E
L E
P H
O N
E O
R D
A T
A O
U T
L E
T
M A
N U
A L F
IR
E
A L A
R M
N U
M E
R
IC
P A
D
C A
R D
R E
A D
E R
P U
S H
B U
T T
O N
S T
A F
F A
S S
IS
T
S W
IT
C
H
T E
L E
P H
O N
E O
U T
L E
T
"C O
D E
B L U
E
S W
IT
C
H
N U
R S
E C
A L L
IN
T
E R
C O
M S
T A
T
IO
N
T H
E R
M O
S T
A T
S T
A T
IO
N
U .N
.O
" 4
M
A X
F
IR
E A
L A
R M
A U
D
IB
L E
V
IS
U A
L S
IG
N
A L
A L L S
C O
N C
E S
T Y
P
CEILING
TV
B O
T T
O M
O F
T V
F L A
T S
C R
E E
N
0' - 6"0' - 6"
M A
X
T O
P O
F F
IR
E
E X
T
IN
G U
IS
H
E R
IF
F
IR
E
E X
T
IN
G U
IS
H
E R
W E
IG
H
S O
V E
R
L
B S
M A
X H
E
IG
H T
F
IR
E E
X T
IN
G
U
IS
H E
R C
A B
IN
E
T
TELEVISION WALL
BRACKET
CHALKBOARD,
TACKBOARD, OR
WHITE BOARD
REFER TO
PLAN FOR SIZE
CLOCK
NURSE CALL DOME LIGHT OR
EXAM ROOM STATUS LIGHT
ALIGN WITH TOP
OF FRAME
ROBE/COAT HOOD
(DOOR OR WALL
MOUNTED)
0' - 2"
SWITCH
AC
C
ES
SI
BL
E
M
AX
1' - 6"
2' - 0".
AT
COUNTER
SINK
AT
LAV
FACE OF WALL
M A
X
P A
P E
R T
O W
E L
D
IS
P E
N S
E R
CHANGING
STATION
M A
X
T O
H A
N D
L E
H O
R
IZ
O N
T A
L P
O S
IT
IO
N
T O
P O
F O
P E
R A
T O
R
SANITARY
NAPKIN &
TAMPON
DISPENSER
S A
N
IT
A R
Y N
A P
K
IN
D
IS
P O
S A
L
T O
IL
E
T S
E A
T C
O V
E R
D
IS
P E
N S
E R
G L O
V E
D
IS
P E
N S
E R
S H
A R
P S
D
IS
P O
S A
L
FILM VIEWER
SIT-DOWN
EO
1" ABOVE
BACK SPLASH4
" 4
APRON
HANGER
E M
E R
G E
N C
Y E
Y E
W A
S H
W A
L L M
O U
N T
E D
S O
A P
D
IS
H
A
T O
H
IN
G E
0' - 3"FROM CORNER
OF
INTERSECTING
PARTITION
FOLDING
UTILITY
SHELF
BASIN
MOUNTED
SOAP
DISPENSER
MIRROR
HAND
DRYER
H .C
T O
B O
T T
O M
O F
R E
F L E
C T
E D
S U
R F
A C
E M
A X
M E
N
W O
M E
N
H A
N D
IC
A
P
H A
N D
IC
A
P P
E D
COAT HOOK
STRIP
VACUUM
BREAKER
JANITORS
UTILITY SHELF
EQ EQ
1' - 0"
A F
F
TYPICAL
HOUSEKEEPING
CLOSET
MOP AND BROOM
HOLDER W/
UTILITY SHELF
MOP
NIC
MOP
SINK
[178mm] [1 m m
T
IL
E W
A
IN
S C
O T
24" x 36" [610mm x 900mm]
MIRROR
SOAP
DISP. (V.V.)
OFFSET
WASTE NOTE
#3
KNEE CLEARANCE PER
SECTION 306 ADA-ABA
FILLER @
WALL
PAPER TOWEL
DISPENSER
SEE NOTE #2
SIDE ELEVATION
S.S. SHELF
T-45 SEE NOTE
#1 DETAIL B6
NOTE:
1. SHELF IF IN EQUIPMENT
LIST 7610; SEE DETAIL 10
28 00-4
2. LAVATORY, WITH WRIST
OR SENSOR CONTROL
FAUCET
3. INSULATE HOT SUPPLY
AND WASTE.
18"
7"
[450mm]
CL
CL
5'-6"
MIN.
M
IN
1'-6"
M
IN
6"
MIN.
36"
MIN.
8"
M
IN
1'-6"
1'-0" 2'-0"
M A
X
1 1/2" BETWEEN
SET FLUSH VALVE
PROJECTING OBJECTS
GRAB BAR AND
SIDE OF STALL
HANDLE TO WIDE
OTHER FIXTURES
NOT ALLOWED
WITHIN THIS CLEAR
FLOOR SPACE
TOILET PAPER
DISPENSER
GRAB BAR
GRAB BAR
TOILET PAPER
DISPENSER
GRAB BAR
PLAN
FRONT ELEVATION SIDE ELEVATION
TOILET PAPER
DISPENSER AREA,
COMPLY W/ GRAB
BAR SPACING, SEE
DETAIL F8
1 1/2 CLEAR
H O
L D
S E
A T
T O
P O
F
M A
X
[1 m m
[8 m m
[8 m m
M
IN
SEE AE-561 FOR SWING UP GRAB BAR
UPSWING GRAB
BAR WHERE
SCHEDULED
UPSWING GRAB
BAR WHERE
SCHEDULED
ROD
B B
C
ROBE HOOK
SLOPE ENTIRE
FLOOR AS
SHOWN
A
FULL HGT.
C.T. AT
SHOWER
CEMENT
PLASTER
CEILING
NURSE CALL
WITH PULL
CORD
CURTAIN ROD
GRAB BAR
SLIDE BAR
SOAP HOLDER
(RECESSED) 40"
AFF (1000mm)
VACUUM BREAKER
THERMOMETER
(SCI ONLY)
CONTROLS
VA BARRIER FREE DESIGN GUIDE PG-18-13 SPECIFIES MINIMUM 48"x48" [1200x1200mm] ROLL-IN TYPE SHOWER FOR PATIENT
BATHING. 90% OF INDIVIDUAL SHOWERS IN MEDICAL-SURGICAL NURSING UNITS (MSN) AND NURSING HOME CARE UNITS
(NHCU) SHOULD BE THIS SIZE TO FACILITATE USE OF WHEELCHAIRS, SHOWER SEATS, AND ASSISTED BATHING.
TRANSFER TYPE 36"x36" [900x900mm] AND 30"x60" [750x1500mm] ROLL-IN LITTER SHOWERS MAY BE USED FOR MENTAL
HEALTH (MH&B) UNITS, DOMICILIARY, AND STAFF FACILITIES. REFER TO CHAPTER 6 OF THE ADA-ABA ACCESSIBILITY
GUIDELINES FOR CRITICAL DIMENSIONS AND GRAB BAR AND ACCESSORY LOCATIONS.
A/E SHALL CAREFULLY COORDINATE FLOOR SLOPES AND DRAIN LOCATIONS TO CONTAIN AND CONTROL WATER FROM THE
SHOWER. IN NEW CONSTRUCTION USE 3" [75mm] SLAB DEPRESSION AT SHOWER AND ADJOINING TOILET OR DRYING AREA.
PLAN
C
4" (100mm) STUDS, 8" (200mm) STUDS
WITH BACK TO
BACK SHOWER
HEADS
GRAB BAR (TYP.)
3'-0" (915mm)
AFF (TYP.)
RECESSED
SOAP
HOLDER
A
NOTES:
SIDE ELEVATION REAR ELEVATION SIDE ELEVATION (CONTROL WALL)CBA
m m
48" [1200mm] MIN.
60" [1500mm] PREFERRED
[7 m m
M
IN
T
O N
E A
R E
S T
O R
O B
S T
R U
C T
IO
N
48" MIN.
[1200mm]
T Y
P T
O
IL
E T
R O
O M
[1 m m W
S C
T
36" [900mm] 6"
[150mm]
[1 m m
M
IN
IN
S H
O W
E R
S T
A L L
48" [1200mm]
36" [900mm]
6" [150mm]
4" [100mm]
18" [450mm]
6" [150mm]
[8 m m
[7 m m
[4 m m
[2 m m
[1 m m M
IN
6" 6' - 5 7/8" 6"
7' - 6"
NOTE: SEE DETAIL B8, SHEET
AE-563 FOR ADDITIONAL
INFORMATION
2'-8" MIN.
M
IN
(4
M
IN
IF
D O
O R
H A
S C
L O
S E
R
24" MIN.24" MIN.
M
IN
(5
M
IN
IF
D O
O R
H A
S C
L O
S E
R
54" MIN.
Y
36" MIN. IF Y=60"
42" MIN. IF Y=54"
M
IN
(4
M
IN
IF
D O
O R
H A
S B
O T
H L
A T
C H
A N
D C
L O
S E
R
12" MIN. IF DOOR HAS
BOTH A CLOSER
AND A LATCH
M
IN
M
IN
18" MIN., 24"
PREFERRED
22" MIN.
PUSH SIDE
PULL SIDE
PULL SIDE
PUSH SIDE
PUSH SIDE
PULL SIDE
HINGED DOOR - CLEAR
DOORWAY WIDTH
34" MIN CLEAR WIDTH FOR
VA RESTROOM ENTRY
DOORS
NOT REQUIRED FOR
PATIENT ROOM DOORS
3'-8" OR WIDER
NOT REQUIRED FOR
PATIENT ROOM DOORS
3'-8" OR WIDER
NOT REQUIRED FOR
PATIENT ROOM DOORS
3'-8" OR WIDER
NOT REQUIRED FOR
PATIENT ROOM DOORS
3'-8" OR WIDER
NOT REQUIRED FOR
PATIENT ROOM DOORS
3'-8" OR WIDER
SPACING. THE SPACE BETWEEN THE
WALL AND THE GRAB BAR SHALL
BE 1 1/2 INCHES (38 MM). THE
SPACE BETWEEN THE GRAB BAR
AND PROJECTING OBJECTS BELOW
AND AT THE ENDS SHALL BE 1 1/2
INCHES (38 MM) MINIMUM. THE
SPACE BETWEEN THE GRAB BAR
AND PROJECTING OBJECTS ABOVE
SHALL BE 12 INCHES (305 MM)
MINIMUM.
EXCEPTION: THE SPACE BETWEEN
THE GRAB BARS AND SHOWER
CONTROLS, SHOWER FITTINGS, AND
OTHER GRAB BARS ABOVE SHALL
BE PERMITTED TO BE 1 1/2 INCHES
(38 MM) MINIMUM.
/2
PROJECTED OBJECTS RECCESSED OBJECTS
HIGH
LOW
STANDARD
STANDARD ACCESSIBLE
ALCOVES WALL
LINE BEYOND,
SEE PLAN
CLEAR
FLOOR
SPACE
TO SPOUT
OUTLET
15"
MIN.
6" MAX.
TOE CLR.
8"MIN. KNEE CLR.
REDUCTION
9" MIN.
TOE CLR.
5"
MAX.
M
IN
2'-6"
MIN. REQ'D.
SEE PLAN
1'-3"
MIN.
M A
X
F O
R S
T A
N D
IN
G
P E
R S
O N
S
M
IN
5"
MAX.
11" MIN.
KNEE CLR.
M A
X
M
IN
B. FRONTC. SIDE
A. PLAN
T O
S P
O U
T O
U T
L E
T
BE MOUNTED AT ACCESSIBLE HEIGHT.
NOTE: ONE OF EACH PAIR, MINIMUM SHALL
ONE OF EACH PAIR, MINIMUM SHALL
CLR
BE MOUNTED AT STANDARD HEIGHT
17"~25"
KNEE CLR.
PROVIDE CANE
DETION PANEL
30"x48"
CLEAR FLOOR
SPACE
M A
X
M A
X
M A
X
S T
A N
D A
R D
H E
IG
H
T
FRONT ELEVATIONPLAN
/2
M
IN
FINISHED
WALL
STOCK S.S. SHELF
BRACKETS FOR S.S.
SHELF AS REQ'D.
ANCHORAGE
STD. DTL.
05500-2
TOP OF SHELF TYPE 45C SHALL BE LOCATED 1'-5" [432mm] ABOVE RIM OF UTILITY SINK.
WHERE SHELF TYPE 45C OCCURS ABOVE FLUSHING RIM SERVICE SINK IT SHALL CLEAR FITTING
SUPPORT A MINIMUM OF 2" [51mm].
SEE ARCH. PLANS FOR EXTENT OF SHELVING AND ACTUAL SPACING OF BRACKETS.
[3 m m
T O
R
IM
O F
L A
V
F O
R T
Y P
E
S
E E
N O
T E
S F
O R
T Y
P E
C
SEE ROOM
SCHEDULE REQ'D
SIZES
AND FOR
5" [127mm]1'-0" [305mm]
3'-0" [914mm]
SECTION "A-A"ELEVATION
OVER LAVATORIES WHERE
REQUIRED
OVER UTILITY AND FLUSHING RIM
SERVICE SINK WHERE REQUIRED
TYPE
45C
FOR TYPE 45FOR TYPE 45
FOR TYPE 45C
A
A
1.
2.
5.
GENERAL NOTES:
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
Drawing Number
DrawnChecked
Dwg. of Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
V eterans Affairs P alo Alto Heal th Ca re Sy stem
S cale: 1 "= 20'-0"S cale: 1-1 /2"= 1'-0"S cale: 1"= 1'-0"S cale: 3/ 32"= 1'-0"S cale: 1/ 16"= 1'-0"S cale: 3/ 16"= 1'-0"S cale: 3/ 4"= 1'-0"S cale: 3/ 8"= 1'-0"S cale: 1/ 2"= 1'-0"S cale: 1/ 4"= 1'-0"
AV P AHC SV eterans Affairs P alo Alto Heal th Ca re Sy stem
D ESIGN DEVE LO PM ENT - NO T FO R CO NSTRUCTIO NF ULLY SPR INKL ERED
T exas Reg. No.G FE Project No.F-571213060
Issued for Bidding & Construction 06/08/18 212Author
SCS
Checker
MDM
06/08/18
GI-021
ACCESSIBLITY & MOUNTING HEIGHTS CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON, TX 77030
#580 - 320
0' 2' 4'1' 6' 3/8" = 1'-0"
TYPICAL MOUNTING HEIGHTS
A1
NOTE:
CONTRACTOR SHALL COMPLY WITH MOST RECENT VA BARRIER FREE DESIGN GUIDE, PG-18-13 AND ARCHITECTURAL BARRIERS ACT STANDARDS (ABA)
UNO CONTRACTOR SHALL CAREFULLY COORDINATE FLOOR SLOPES AND DRAIN LOCATIONS TO CONTAIN AND CONTROL WATER FROM THE SHOWER.
COORDINATE W/ MEP DRAWINGS AND SPECIFICATIONS
0' 2' 4'1' 3/8" = 1'-0"
TOILET DETAILS - VA REQUIREMENTS
F1
0' 2' 4'1' 3/8" = 1'-0"
PATIENT ACCESSIBLE SHOWER ROLL-IN
D1 0' 2' 4'1'
3/8" = 1'-0"
ACCESSIBLE MANEUVERING
CLEARANCES AT DOORS
D8
N.T.S.
GRAB BAR SPACING
F80' 2' 4'1'
3/8" = 1'-0"
DRINKING FOUNTAIN
F6
0' 2' 4'1' 3/8" = 1'-0"
TYP. ACCESSIBLE URINAL
D6
N.T.S.
SHELVES TYPE 45 & 45C
B6
1. FLOOR AND CEILING RUNNERS — (NOT SHOWN) — CHANNEL SHAPED RUNNERS, 3-
5/8 IN. DEEP (MIN), 1-1/4 IN. LEGS, FORMED FROM MIN NO. 25 MSG GALV STEEL,
ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED 24 IN. OC MAX.
1A. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — (NOT SHOWN) — AS
AN ALTERNATE TO ITEM 1 - CHANNEL SHAPED, MIN 3-5/8 IN. DEEP, ATTACHED TO
FLOOR AND CEILING WITH FASTENERS 24 IN. OC. MAX.
ALLSTEEL & GYPSUM PRODUCTS INC — TYPE SUPREME FRAMING SYSTEM
CONSOLIDATED FABRICATORS CORP, BUILDING PRODUCTS DIV — TYPE SUPREME
FRAMING SYSTEM
QUAIL RUN BUILDING MATERIALS INC — TYPE SUPREME FRAMING SYSTEM
SCAFCO STEEL STUD MANUFACTURING CO — TYPE SUPREME FRAMING SYSTEM
STEEL CONSTRUCTION SYSTEMS INC — TYPE SUPREME FRAMING SYSTEM
UNITED METAL PRODUCTS INC — TYPE SUPREME FRAMING SYSTEM
1B. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — NOT SHOWN — IN
LIEU OF ITEM 1 — FOR USE WITH ITEM 2B, PROPRIETARY CHANNEL SHAPED
RUNNERS, 1-1/4 IN. WIDE BY MIN 3-5/8 IN. DEEP FABRICATED FROM MIN 0.020 IN.
THICK GALV STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED
24 IN. OC MAX.
CALIFORNIA EXPANDED METAL PRODUCTS CO — VIPER20™ TRACK
CRACO MFG INC — SMARTTRACK20™
MARINO/WARE, DIV OF WARE INDUSTRIES INC — VIPER20™ TRACK
1C. FLOOR AND CEILING RUNNERS — (NOT SHOWN) — FOR USE WITH ITEM 2C —
CHANNEL SHAPED, FABRICATED FROM MIN 20 MSG CORROSION-PROTECTED OR
GALV STEEL, MIN DEPTH TO ACCOMMODATE STUD SIZE, WITH MIN 1 IN. LONG
LEGS, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED MAX 24 IN. OC.
1D. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — NOT SHOWN — IN
LIEU OF ITEMS 1 THROUGH 1C — FOR USE WITH ITEM 2D AND 4G ONLY,
PROPRIETARY CHANNEL SHAPED RUNNERS, 1-1/4 IN. DEEP BY MIN 3-5/8 IN. WIDE
FABRICATED FROM MIN 0.018 IN. THICK GALV STEEL, ATTACHED TO FLOOR AND
CEILING WITH FASTENERS SPACED 24 IN. OC MAX.
CLARKDIETRICH BUILDING SYSTEMS — CD PROTRAK
DMFCWBS L L C — PROTRAK
MBA METAL FRAMING — PROTRAK
RAM SALES L L C — RAM PROTRAK
STEEL STRUCTURAL PRODUCTS L L C — TRI-S PROTRAK
1E. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — NOT SHOWN — IN
LIEU OF ITEMS 1 THROUGH 1D — FOR USE WITH ITEM 2E AND 4I ONLY,
PROPRIETARY CHANNEL SHAPED RUNNERS, 1-1/4 IN. DEEP BY MIN 3-5/8 IN. WIDE
FABRICATED FROM MIN 0.018 IN. THICK GALV STEEL, ATTACHED TO FLOOR AND
CEILING WITH FASTENERS SPACED 24 IN. OC MAX.
TELLING INDUSTRIES L L C — TRUE-TRACK™
1F. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — NOT SHOWN — IN
LIEU OF ITEMS 1 THROUGH 1E — FOR USE WITH ITEM 2, CHANNEL SHAPED
RUNNERS, 1-1/4 IN. DEEP BY MIN 3-5/8 IN. WIDE FABRICATED FROM MIN 25 MSG
STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED 24 IN. OC
MAX.
KIRII (HONG KONG) LTD — TYPE KIRII
1G. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — NOT SHOWN — IN
LIEU OF ITEMS 1 THROUGH 1F — FOR USE WITH ITEM 2, CHANNEL SHAPED
RUNNERS, 1-1/4 IN. DEEP BY MIN 3-5/8 IN. WIDE, ATTACHED TO FLOOR AND CEILING
WITH FASTENERS SPACED 24 IN. OC MAX.
STUDCO BUILDING SYSTEMS — CROCSTUD TRACK
1H. FLOOR AND CEILING RUNNERS — (NOT SHOWN) — CHANNEL SHAPED,
FABRICATED FROM MIN 0.02 IN. GALV STEEL, MIN WIDTH TO ACCOMMODATE STUD
SIZE, WITH MIN 1 IN. LONG LEGS, FOR USE WITH STUDS SPECIFIED BELOW AND
FABRICATED FROM MIN 0.02 IN. GALV STEEL OR THICKER, ATTACHED TO FLOOR
AND CEILING WITH FASTENERS SPACED MAX 24 IN. OC.
MARINO/WARE, DIV OF WARE INDUSTRIES INC — VIPER20™ TRACK VT100
1I. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — NOT SHOWN — IN LIEU
OF ITEM 1 — FOR USE WITH ITEM 2H, PROPRIETARY CHANNEL SHAPED RUNNERS, 1-
1/4 IN. WIDE BY MIN 3-5/8 IN. DEEP FABRICATED FROM MIN 0.020 IN. THICK GALV
STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED 24 IN. OC
MAX.
TELLING INDUSTRIES L L C — VIPER20™ TRACK
1J. FRAMING MEMBERS* — FLOOR AND CEILING RUNNERS — (NOT SHOWN) — AS
AN ALTERNATE TO ITEM 1 - FOR USE WITH ITEM 2L. CHANNEL SHAPED, ATTACHED
TO FLOOR AND CEILING WITH FASTENERS 24 IN. OC. MAX.
BAILEY METAL PRODUCTS LTD — TYPE PLATINUM PLUS
2. STEEL STUDS — CHANNEL SHAPED, 3-5/8 IN. DEEP (MIN), FORMED FROM MIN NO.
25 MSG GALV STEEL SPACED 24 IN. OC MAX. STUDS TO BE CUT 3/4 IN. LESS THAN
ASSEMBLY HEIGHT.
2A. FRAMING MEMBERS* — STEEL STUDS — AS AN ALTERNATE TO ITEM 2 —
CHANNEL SHAPED STUDS, MIN 3-5/8 IN. DEEP, SPACED A MAX OF 24 IN. OC. STUDS
TO BE CUT 3/4 IN. LESS THAN ASSEMBLY HEIGHT.
ALLSTEEL & GYPSUM PRODUCTS INC — TYPE SUPREME FRAMING SYSTEM
CONSOLIDATED FABRICATORS CORP, BUILDING PRODUCTS DIV — TYPE SUPREME
FRAMING SYSTEM
QUAIL RUN BUILDING MATERIALS INC — TYPE SUPREME FRAMING SYSTEM
SCAFCO STEEL STUD MANUFACTURING CO — TYPE SUPREME FRAMING SYSTEM
STEEL CONSTRUCTION SYSTEMS INC — TYPE SUPREME FRAMING SYSTEM
UNITED METAL PRODUCTS INC — TYPE SUPREME FRAMING SYSTEM
2B. FRAMING MEMBERS* — STEEL STUDS — NOT SHOWN — IN LIEU OF ITEM 2 —
FOR USE WITH ITEM 1B, PROPRIETARY CHANNEL SHAPED STEEL STUDS, 1-1/4 IN.
WIDE BY MIN 3-5/8 IN. DEEP FABRICATED FROM MIN 0.020 IN. THICK GALV STEEL.
STUDS CUT 3/4 IN. LESS IN LENGTH THAN ASSEMBLY HEIGHT.
CALIFORNIA EXPANDED METAL PRODUCTS CO — VIPER20™
CRACO MFG INC — SMARTSTUD20™
MARINO/WARE, DIV OF WARE INDUSTRIES INC — VIPER20™
2C. STEEL STUDS — (AS AN ALTERNATE TO ITEM 2, FOR USE WITH ITEM 4E) —
CHANNEL SHAPED, FABRICATED FROM MIN 20 MSG CORROSION-PROTECTED OR
GALV STEEL, 3-1/2 IN. MIN DEPTH, SPACED A MAX OF 16 IN. OC. STUDS FRICTION-
FIT INTO FLOOR AND CEILING RUNNERS. STUDS TO BE CUT 5/8 TO 3/4 IN. LESS
THAN ASSEMBLY HEIGHT.
2D. FRAMING MEMBERS* — STEEL STUDS — AS AN ALTERNATE TO ITEMS 2
THROUGH 2C— FOR USE WITH ITEM 1D AND 4G ONLY, CHANNEL SHAPED STUDS, MIN
3-5/8 IN. WIDE FABRICATED FROM MIN 0.018 IN. THICK GALV STEEL, SPACED A MAX
OF 24 IN. OC. STUDS TO BE CUT 1/2 IN. LESS THAN ASSEMBLY HEIGHT.
CLARKDIETRICH BUILDING SYSTEMS — CD PROSTUD
DMFCWBS L L C — PROSTUD
MBA METAL FRAMING — PROSTUD
RAM SALES L L C — RAM PROSTUD
STEEL STRUCTURAL PRODUCTS L L C — TRI-S PROSTUD
2E. FRAMING MEMBERS* — STEEL STUDS — AS AN ALTERNATE TO ITEMS 2
THROUGH 2D — FOR USE WITH ITEM 1E AND 4I ONLY, CHANNEL SHAPED STUDS, MIN
3-5/8 IN. WIDE FABRICATED FROM MIN 0.018 IN. THICK GALV STEEL, SPACED A MAX
OF 24 IN. OC. STUDS TO BE CUT 1/2 IN. LESS THAN ASSEMBLY HEIGHT.
TELLING INDUSTRIES L L C — TRUE-STUD™
2F. FRAMING MEMBERS* — STEEL STUDS — AS AN ALTERNATE TO ITEMS 2
THROUGH 2E — FOR USE WITH ITEM 1F, CHANNEL SHAPED STUDS, MIN 3-5/8 IN.
WIDE FABRICATED FROM MIN 25 MSG STEEL, SPACED A MAX OF 24 IN. OC. STUDS
TO BE CUT 1/2 IN. LESS THAN ASSEMBLY HEIGHT.
KIRII (HONG KONG) LTD — TYPE KIRII
2G. FRAMING MEMBERS* — STEEL STUDS — NOT SHOWN — IN LIEU OF ITEM 2
THROUGH 2F — FOR USE WITH ITEM 1G. PROPRIETARY CHANNEL SHAPED STUDS,
MINIMUM 3-5/8 IN. WIDE, STUDS TO BE CUT 1/2 IN. LESS THAN THE ASSEMBLY
HEIGHT.
STUDCO BUILDING SYSTEMS — CROCSTUD
2H. FRAMING MEMBERS* — STEEL STUDS — NOT SHOWN — IN LIEU OF ITEM 2 —
FOR USE WITH ITEM 1I, PROPRIETARY CHANNEL SHAPED STEEL STUDS, 1-1/4 IN.
WIDE BY MIN 3-5/8 IN. DEEP FABRICATED FROM MIN 0.020 IN. THICK GALV STEEL.
STUDS CUT 3/4 IN. LESS IN LENGTH THAN ASSEMBLY HEIGHT.
TELLING INDUSTRIES L L C — VIPER20™
2I. FRAMING MEMBERS* — STEEL STUDS — IN LIEU OF ITEM 2 — FOR USE WITH
ITEM 1, CHANNEL SHAPED STUDS, FABRICATED FROM MIN 25 MSG CORROSION-
PROTECTED STEEL, 3-5/8 IN. DEEP (MIN), SPACED 24 IN. OC MAX. STUDS TO BE CUT
3/4 IN. LESS THAN ASSEMBLY HEIGHT.
EB MÉTAL INC — EB STUD
2J. FRAMING MEMBERS* — STEEL STUDS — IN LIEU OF ITEM 2 — FOR USE WITH
ITEM 1, CHANNEL SHAPED STUDS, FABRICATED FROM MIN 25 MSG CORROSION-
PROTECTED STEEL, 3-5/8 IN. DEEP (MIN), SPACED 24 IN. OC MAX. STUDS TO BE CUT
3/4 IN. LESS THAN ASSEMBLY HEIGHT.
OLMAR SUPPLY INC — PRIMESTUD
2K. FRAMING MEMBERS* — STEEL STUDS — AS AN ALTERNATE TO ITEM 2 — FOR
USE WITH ITEM 1B (3-5/8 IN. WIDE TRACK), CHANNEL SHAPED STUDS, FABRICATED
FROM MIN 25 MSG CORROSION-PROTECTED STEEL, 1-1/4 IN. WIDE BY 3-5/8 IN.
DEEP, SPACED A MAX OF 24 IN. OC. STUDS TO BE CUT 3/8 TO 3/4 IN. LESS THAN
ASSEMBLY HEIGHT.
MARINO/WARE, DIV OF WARE INDUSTRIES INC — STUDRITE™
2L. FRAMING MEMBERS* — STEEL STUDS — AS AN ALTERNATE TO ITEM 2 — FOR
USE WITH ITEM 1J, CHANNEL SHAPED, MIN 3-5/8 IN. WIDE, SPACED A MAX OF 24
IN. OC. STUDS TO BE CUT 3/8 TO 3/4 IN. LESS THAN ASSEMBLY HEIGHT.
BAILEY METAL PRODUCTS LTD — TYPE PLATINUM PLUS
3. BATTS AND BLANKETS* — (OPTIONAL) — MINERAL WOOL OR GLASS FIBER BATTS
PARTIALLY OR COMPLETELY FILLING STUD CAVITY.
SEE BATTS AND BLANKETS (BZJZ) CATEGORY FOR NAMES OF CLASSIFIED
COMPANIES.
3A. FIBER, SPRAYED* — AS AN ALTERNATE TO BATTS AND BLANKETS (ITEM 3) —
(100% BORATE FORMULATION) — SPRAY APPLIED CELLULOSE MATERIAL. THE
FIBER IS APPLIED WITH WATER TO COMPLETELY FILL THE ENCLOSED CAVITY IN
ACCORDANCE WITH THE APPLICATION INSTRUCTIONS SUPPLIED WITH THE PRODUCT
WITH A NOMINAL DRY DENSITY OF 2.7 LB/FT3. ALTERNATE APPLICATION METHOD:
THE FIBER IS APPLIED WITHOUT WATER OR ADHESIVE AT A NOMINAL DRY DENSITY
OF 3.5 LB/FT3, IN ACCORDANCE WITH THE APPLICATION INSTRUCTIONS SUPPLIED
WITH THE PRODUCT.
U S GREENFIBER L L C — INS735& INS745 FOR USE WITH WET OR DRY
APPLICATION. INS765LD AND INS770LD ARE TO BE USED FOR DRY APPLICATION
ONLY
3B. FIBER, SPRAYED* — AS AN ALTERNATE TO BATTS AND BLANKETS (ITEM 3) AND
ITEM 3A — SPRAY APPLIED CELLULOSE INSULATION MATERIAL. THE FIBER IS
APPLIED WITH WATER TO INTERIOR SURFACES IN ACCORDANCE WITH THE
APPLICATION INSTRUCTIONS SUPPLIED WITH THE PRODUCT. APPLIED TO
COMPLETELY FILL THE ENCLOSED CAVITY. MINIMUM DRY DENSITY OF 4.3 POUNDS
PER CUBIC FT.
NU-WOOL CO INC — CELLULOSE INSULATION
3C. FIBER, SPRAYED* — AS AN ALTERNATE TO BATTS AND BLANKETS (ITEM 3) —
SPRAY APPLIED CELLULOSE FIBER. THE FIBER IS APPLIED WITH WATER TO
COMPLETELY FILL THE ENCLOSED CAVITY IN ACCORDANCE WITH THE APPLICATION
INSTRUCTIONS SUPPLIED WITH THE PRODUCT. THE MINIMUM DRY DENSITY SHALL
BE 4.30 LBS/FT3.
INTERNATIONAL CELLULOSE CORP — CELBAR-RL
3D. BATTS AND BLANKETS* — FOR USE WITH ITEM 8. NOM 3 IN. THICK, MINIMUM
3.4 PCF MINERAL WOOL BATTS, FRICTION FIT BETWEEN THE STUDS AND FLOOR
AND CEILING RUNNERS.
SEE BATTS AND BLANKETS (BZJZ) CATEGORY FOR NAMES OF MANUFACTURERS.
3E. BATTS AND BLANKETS* — FOR USE WITH ITEM 4P. PLACED IN STUD CAVITIES,
ANY MIN. 3-1/2 IN. THICK GLASS FIBER INSULATION BEARING THE UL
CLASSIFICATION MARKING AS TO SURFACE BURNING CHARACTERISTICS AND/OR FIRE
RESISTANCE. SEE BATTS AND
BLANKETS (BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES.
4. GYPSUM BOARD* — 5/8 IN. THICK, 4 FT WIDE, ATTACHED TO STEEL STUDS AND
FLOOR AND CEILING TRACK WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 8 IN.
OC. ALONG EDGES OF BOARD AND 12 IN. OC IN THE FIELD OF THE BOARD. JOINTS
ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY.
WHEN ATTACHED TO ITEM 6 (RESILIENT CHANNELS) OR 6A, 6B OR 6C (FURRING
CHANNELS), GYPSUM BOARD IS SCREW ATTACHED TO FURRING CHANNELS WITH 1
IN. LONG, TYPE S STEEL SCREWS SPACED 12 IN. OC.
ACADIA DRYWALL SUPPLIES LTD — TYPE X, 5/8 TYPE X, TYPE BLUEGLASS
EXTERIOR SHEATHING
AMERICAN GYPSUM CO — TYPES AG-C, AGX-1, M-GLASS
BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO — TYPE DBX-1
CGC INC — TYPES AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, USGX, WRC OR WRX
(JOINT TAPE AND COMPOUND, ITEM 5, OPTIONAL FOR USE WITH TYPE USGX)
CERTAINTEED GYPSUM INC — TYPES 1, EGRG, GLASROC, TYPE X, TYPE X-1, TYPE C,
SILENTFX, 5/8" EASI-LITE TYPE X
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — TYPES LGFC2A,
LGFC6A, LGFC-C/A, LGFC-WD, LGLLX
GEORGIA-PACIFIC GYPSUM L L C — TYPES 5, 6, 9, C, DAP, DD, DA, DAPC, DGG, DS,
GPFS6, LS, , TYPE X, VENEER PLASTER BASE - TYPE X, WATER RATED - TYPE X,
SHEATHING - TYPE X, SOFFIT - TYPE X, TG-C, GREENGLASS TYPE X, TYPE X
COMFORTGUARD SOUND DEADENING GYPSUM BOARD, TYPE LWX, VENEER PLASTER
BASE-TYPE LWX, WATER RATED-TYPE LWX, SHEATHING TYPE-LWX, SOFFIT-TYPE
LWX, TYPE DGLW, WATER RATED-TYPE DGLW, SHEATHING TYPE- DGLW, SOFFIT-
TYPE DGLW, TYPE LW2X, VENEER PLASTER BASE - TYPE LW2X, WATER RATED -
TYPE LW2X, SHEATHING - TYPE LW2X, SOFFIT - TYPE LW2X, TYPE DGL2W, WATER
RATED - TYPE DGL2W, SHEATHING - TYPE DGL2W
NATIONAL GYPSUM CO — TYPES EXP-C, FSK, FSK-C, FSK-G, FSMR-C, FSW-C, FSW-G,
FSW, FSW-3, FSW-5, FSW-6, FSW-8, FSL
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — TYPES PG-C, PG-9, PG-11,
PGS-WRS
PANEL REY S A — TYPES GREX, PRC, PRC2, PRX, RHX, MDX, ETX
SAINT-GOBAIN GYPROC MIDDLE EAST FZE — TYPE GYPROC FIRESTOP, GYPROC
FIRESTOP MR, GYPROC FIRESTOP M2TECH, GYPROC FIRESTOP ACTIV'AIR, GYPROC
FIRESTOP MR ACTIV'AIR, GYPROC FIRESTOP M2TECH ACTIV'AIR, GYPROC DURALINE,
GYPROC DURALINE MR, GYPROC DURALINE M2TECH, GYPROC DURALINE ACTIV'AIR,
GYPROC DURALINE MR ACTIV'AIR, GYPROC DURALINE M2TECH ACTIV'AIR
SIAM GYPSUM INDUSTRY (SARABURI) CO LTD — TYPE EX-1
THAI GYPSUM PRODUCTS PCL — TYPE X, TYPE C
UNITED STATES GYPSUM CO — TYPE AR, C, FRX-G, IP-AR, IP-X1, IP-X2, IPC-AR, SCX,
SHX, WRC, WRX, USGX (JOINT TAPE AND COMPOUND, ITEM 5, OPTIONAL FOR USE
WITH TYPE USGX)
USG BORAL ZAWAWI DRYWALL L L C SFZ — TYPES C, SCX
USG MEXICO S A DE C V — TYPE AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, USGX,
WRC OR WRX (JOINT TAPE AND COMPOUND, ITEM 5, OPTIONAL FOR USE WITH TYPE
USGX)
4A. GYPSUM BOARD* — (AS ALTERNATE TO ITEM 4) — NOM 5/8 IN. THICK GYPSUM
PANELS WITH BEVELED, SQUARE OR TAPERED EDGES, APPLIED VERTICALLY OR
HORIZONTALLY. VERTICAL JOINTS CENTERED OVER STUDS AND STAGGERED ONE
STUD CAVITY ON OPPOSITE SIDES OF STUDS. HORIZONTAL EDGE JOINTS AND
HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED NOT BE STAGGERED
OR BACKED BY STEEL FRAMING. PANELS ATTACHED TO STEEL STUDS AND FLOOR
RUNNER WITH 1 IN. LONG TYPE S STEEL SCREWS SPACED 8 IN. OC WHEN APPLIED
HORIZONTALLY, OR 8 IN. OC ALONG VERTICAL AND BOTTOM EDGES AND 12 IN. OC IN
THE FIELD WHEN PANELS ARE APPLIED VERTICALLY. WHEN USED IN WIDTHS OTHER
THAN 48 IN., GYPSUM PANELS TO BE INSTALLED HORIZONTALLY.
CERTAINTEED GYPSUM INC — TYPE X, TYPE X-1, TYPE C, TYPE EGRG/ GLASROC.
CGC INC — TYPES AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, USGX, WRC OR WRX
(JOINT TAPE AND COMPOUND, ITEM 5, OPTIONAL FOR USE WITH TYPE USGX)
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — TYPES LGFC2A,
LGFC6A, LGFC-C/A, LGFC-WD
GEORGIA-PACIFIC GYPSUM L L C — TYPES DAP, DAPC, DGG, DS
SAINT-GOBAIN GYPROC MIDDLE EAST FZE — TYPE GYPROC FIRESTOP, GYPROC
FIRESTOP MR, GYPROC FIRESTOP M2TECH, GYPROC FIRESTOP ACTIV'AIR, GYPROC
FIRESTOP MR ACTIV'AIR, GYPROC FIRESTOP M2TECH ACTIV'AIR, GYPROC DURALINE,
GYPROC DURALINE MR, GYPROC DURALINE M2TECH, GYPROC DURALINE ACTIV'AIR,
GYPROC DURALINE MR ACTIV'AIR, GYPROC DURALINE M2TECH ACTIV'AIR
THAI GYPSUM PRODUCTS PCL — TYPE X, TYPE C
UNITED STATES GYPSUM CO — TYPES AR, C, FRX-G, IP-AR, IP-X1, IP-X2, IPC-AR,
SCX, SHX, WRC, WRX, USGX (JOINT TAPE AND COMPOUND, ITEM 5, OPTIONAL FOR
USE WITH TYPE USGX)
USG BORAL ZAWAWI DRYWALL L L C SFZ — TYPES C, SCX
USG MEXICO S A DE C V — TYPE AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, USGX,
WRC OR WRX (JOINT TAPE AND COMPOUND, ITEM 5, OPTIONAL FOR USE WITH TYPE
USGX)
4B. GYPSUM BOARD* — (AS AN ALTERNATE TO ITEMS 4 OR 4A) — NOM 3/4 IN. THICK, 4 FT
WIDE, INSTALLED AS DESCRIBED IN ITEM 4A WITH SCREW LENGTH INCREASED TO 1-1/4 IN.
CGC INC — TYPES AR, IP-AR
UNITED STATES GYPSUM CO — TYPES AR, IP-AR
USG MEXICO S A DE C V — TYPES AR, IP-AR
4C. GYPSUM BOARD* — AS AN ALTERNATE TO ITEMS 4, 4A, AND 4B — NOM. 5/8 IN. THICK
GYPSUM PANELS, WITH SQUARE EDGES, APPLIED HORIZONTALLY. GYPSUM PANELS
FASTENED TO FRAMING WITH 1 IN. LONG BUGLE HEAD STEEL SCREWS SPACED A MAX 8
IN. OC, WITH LAST 2 SCREWS 3/4 IN. AND 4 IN. FROM EACH EDGE OF BOARD. HORIZONTAL
JOINTS NEED NOT BE BACKED BY STEEL FRAMING. HORIZONTAL EDGE JOINTS AND
HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OF STUDS ON INTERIOR WALLS NEED
NOT BE STAGGERED OR BACKED BY STEEL FRAMING.
GEORGIA-PACIFIC GYPSUM L L C — TYPE DGG, GREENGLASS TYPE X
4D. GYPSUM BOARD* — AS AN ALTERNATE TO ITEMS 4, 4A, 4B, AND 4C — NOM. 5/8 IN.
THICK GYPSUM PANELS APPLIED VERTICALLY OR HORIZONTALLY. HORIZONTAL EDGE
JOINTS AND HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED NOT BE
STAGGERED OR BACKED BY STEEL FRAMING. GYPSUM PANELS FASTENED TO FRAMING
WITH 1 IN. LONG TYPE S STEEL SCREWS 8 IN. OC ALONG VERTICAL EDGES AND 12 IN. OC
IN THE FIELD WHEN PANELS ARE APPLIED VERTICALLY. WHEN GYPSUM PANELS APPLIED
HORIZONTALLY, FASTEN TO FRAMING WITH 1 IN. LONG TYPE S STEEL SCREWS SPACED 8
IN. OC ALONG VERTICAL EDGES AND IN THE FIELD. SCREWS SPACED A MAX 12 IN. ALONG
THE TOP AND BOTTOM EDGES OF THE WALL FOR BOTH VERTICAL AND HORIZONTAL
APPLICATIONS.
NATIONAL GYPSUM CO — TYPES EXP-C, FSK, FSK-C, FSK-G, FSL, FSW-C, FSW-G, FSW,
FSW-3, FSW-5, FSW-6, FSW-8, FSMR-C
4E. GYPSUM BOARD* — (AS AN ALTERNATE TO ITEMS 4 THROUGH 4D) — INSTALLED AS
DESCRIBED IN ITEM 4. 5/8 IN. THICK, 4 FT. WIDE, PAPER SURFACED, APPLIED VERTICALLY
ONLY AND FASTENED TO THE STUDS AND PLATES WITH 1 IN. LONG, TYPE S STEEL
SCREWS SPACED, 8 IN. OC. NOT TO BE USED WITH ITEM 6.
NATIO…
This is the start of the file's text. The full file is on GovTribe.