36C25618R0574-015.pdf

PDF 376 KB Posted

Attached to
CLC MODIFICATIONS
Solicitation number
36C25618R0574
Issued by

About this file

36C25618R0574 DRAWING TL LVL 3 - A004 - COURTYARD RAILINGS MODIFICATION - DETAILS.pdf

View the file

Other files

File Type Posted
36C25618R0574-0004000.docx DOCX document
36C25618R0574-0004001.pdf PDF
36C25618R0574-0003000.docx DOCX document
36C25618R0574-0002000.docx DOCX document
36C25618R0574-0001000.docx DOCX document
36C25618R0574-0001001.pdf PDF
36C25618R0574-003.pdf PDF
36C25618R0574-011.pdf PDF
36C25618R0574-014.pdf PDF
36C25618R0574-008.docx DOCX document
36C25618R0574-010.pdf PDF
36C25618R0574-007.docx DOCX document
36C25618R0574-002.pdf PDF
36C25618R0574-005.docx DOCX document
36C25618R0574-016.pdf PDF
36C25618R0574-006.docx DOCX document
36C25618R0574-013.pdf PDF
36C25618R0574-004.xlsx XLSX spreadsheet
36C25618R0574-012.pdf PDF
36C25618R0574-009.pdf PDF
36C25618R0574-001.docx DOCX document
36C25618R0574-000.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

06 E 06 F

06 3

R6AS210

TL.LVL3-A004

TL.LVL3-A0042

HALLWAY

PATIENT

TERRACE

3M226

BUILDING 6

PATIENT

COURTYARD

PATIENT

TERRACE

3M230EX

IS

TI

N

G (V

.I.

F.

EX

IS

TI

N

G (V

.I.

F.

EX

IS

TI

N

G (V

.I.

F.

2'

0"

EX

IS

TI

N

G (V

.I.

F.

EX

IS

TI

N

G (V

.I.

F.

EX

IS

TI

N

G (V

.I.

F.

EX

IS

TI

N

G (V

.I.

F.

2'

0"

EX

IS

TI

N

G (V

.I.

F.

06-L2 119' - 0"

06-L3 137' - 0"

06-L4 155' - 0"

06 33

TL.LVL3-A004

4" 3'

6"

6"

EX

IS

TI

N G

6'

1/

4"

4"

TYP

3' - 0"

TYP

3' - 0"

TYP

3' - 0"

TYP

3' - 0" V.I.F.

END PANEL

V.I.F.

END PANEL

NEW CABLE GUARD SYSTEM

G.C. TO RE-USE CAREFULLY

REMOVED EXISITNG CABLES

FROM EXTERIOR PATIENT

TERRACE @ LEVEL3 BLDG. 6

2'

6" 6"

NEW EXTENDED GLASS GUARDRAIL

MINIMUM 8MM LAMINATED TEMPERED

GLASS REQUIRED

SEE SECTION DETAILS TL.L3-A004

EX

IS

TI

N

G

LEVEL 3

LEVEL 2

LEVEL 4

06-L3 137' - 0"

06-L4 155' - 0"

06 E

AB

O

VE

O

PE

N

IN

G

EX

IS

TI

N

G C

LA

D

D

IN

G 6"

2'

6" 6"

4" A

IR

G

AP

EX

TE

N D

ED

G

U R

AD

R

AI

L

6'

1/

2" 4"

A

IR

G

AP

EX

IS

TI

N

G

3'

6"

3'

6"

N

EW

E

XT

EN

D

ED

G

LA

SS

G U

AR

D

R

AI

L

/2

O

VE

R

AL

L H

EI

G

H T

O F

O

PE

N

IN

G

/2

EXISTING CEILING FINISH

NEW HORIZONTAL

STEEL SUPPORT

NEW HORIZONTAL

STEEL SUPPORT

NEW EXTENDED GLASS

GUARDRAIL SYSTEM

EXISTING GLASS

GUARDRAIL SYSTEM

ALL FLOOR & GLASSRAIL SUPPORT

CONDITIONS TO BE FIELD VERIFIED

NEW CABLE GUARD SYSTEM

G.C. TO RE-USE CAREFULLY

REMOVED EXISITNG CABLES

FROM EXTERIOR PATIENT

TERRACE @ LEVEL3 BLDG. 6

LEVEL 2

LEVEL 3

LEVEL 4

EXISTING CEILING FINISH

NEW HORIZONTAL

STEEL SUPPORT

NEW HORIZONTAL

STEEL SUPPORT

NEW EXTENDED GLASS

GUARDRAIL SYSTEM

EXISTING GLASS

GUARDRAIL SYSTEM

ALL FLOOR & GLASSRAIL SUPPORT

CONDITIONS TO BE FIELD VERIFIED

NEW CABLE GUARD SYSTEM

G.C. TO RE-USE CAREFULLY

REMOVED EXISITNG CABLES

FROM EXTERIOR PATIENT

TERRACE @ LEVEL3 BLDG. 6

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

TL.LVL3-A004

CLC COURTYARD GUARDRAIL

MODIFICATIONS - DETAILS

FEMI FEMI10/29/17

06629-18-104SLVHCS MEDICAL CENTER

NEW ORLEANS, LOUISIANA

Department of Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

1/4" = 1'-0"1

LEVEL 3 INTERIOR PATIENT TERRACE

MODIFICATIONS - PLAN

1/8" = 1'-0"2

BLDG 6 INTERIOR COURTYARD -

TERRACE MODIFICATIONS

1/4" = 1'-0"3

BLDG 6 INTERIOR COURTYARD -

TERRACE MODIFICATION4

3D SECTION - BLDG 6 COURTYARD

MODIFICATIONS

Sheets
TL.LVL3-A004 - CLC COURTYARD GUARDRAIL MODIFICATIONS - DETAILS

File details come from the government source that posted it.