36C25618R0574-014.pdf

PDF 146 KB Posted

Attached to
CLC MODIFICATIONS
Solicitation number
36C25618R0574
Issued by

About this file

36C25618R0574 DRAWING TL LVL 3 - A003 - RAILINGS MODIFICATION - DETAILS.pdf

View the file

Other files

File Type Posted
36C25618R0574-0004000.docx DOCX document
36C25618R0574-0004001.pdf PDF
36C25618R0574-0003000.docx DOCX document
36C25618R0574-0002000.docx DOCX document
36C25618R0574-0001000.docx DOCX document
36C25618R0574-0001001.pdf PDF
36C25618R0574-003.pdf PDF
36C25618R0574-011.pdf PDF
36C25618R0574-008.docx DOCX document
36C25618R0574-015.pdf PDF
36C25618R0574-010.pdf PDF
36C25618R0574-007.docx DOCX document
36C25618R0574-002.pdf PDF
36C25618R0574-005.docx DOCX document
36C25618R0574-016.pdf PDF
36C25618R0574-006.docx DOCX document
36C25618R0574-013.pdf PDF
36C25618R0574-004.xlsx XLSX spreadsheet
36C25618R0574-012.pdf PDF
36C25618R0574-009.pdf PDF
36C25618R0574-001.docx DOCX document
36C25618R0574-000.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TO

TA

L H

EI

G

H T

O F

N E

W A

N

TI

-C

LI

M B/

EX

TR

U D

ED

M

ET

AL

F

EN

C

IN

G

0"

INSIDE FENCING OUTSIDE FENCING

EQ

U

AL

EQ

U

AL

EQ

U

AL

4"

2"

4' - 0"

CL CL

4' - 0"

2"

PROPOSED EXTRUDED

METAL/ANTI-CLIMBIMG FENCING

NEW 2" X 4" X 3/16" STEEL

TOP BEAM WITH END CAPS

EXISTING PLANTER

RELOCATED TO EXTERIOR

SIDE OF NEW FENCING

NEW 4" X 4" X 3/16" STEEL POST

INSTALL NEW PRECAST UNIT

PAVERS WITH WIND UPLIFT

ANCHORS ALL AROUND THE

EXTERIOR SIDE OF NEW FENCING

CL

NEW 2" X 4" X 3/16" STEEL

INTERMEDIATE BEAM

4"

NEW 2" X 4" X 3/16" STEEL

INTERMEDIATE BEAM

EXISTING 4" X 4" X 3/16" STEEL POST

EX

IS

TI

N G

S

TE

EL

P

O

ST

H

EI

G H

T

- V

.I.

F.

6'

0"

N

EW

F R

AM

IN

G S

U

PP

O R

T

FO

R N

EW

F

EN

C

IN

G

5'

EXISTING PRECAST UNIT PAVERS

WITH WIND UPLIFT ANCHORS

WELDED STEEL PLATE CONNECTION

@ EXISTING & NEW STEEL POST.

VERIFY ALL ROOF CONDITIONS,

PENETRATIONS, AND EXISTING

STEEL FRAMING SUPPORT IN FEILD

EQUAL

4' - 0"

EQUAL

4' - 0"

EQ

U

AL

EQ

U

AL

EQ

U

ALPROPOSED EXTRUDED

METAL/ANTI-CLIMBIMG FENCING

VERIFY ALL ROOF CONDITIONS,

PENETRATIONS, AND EXISTING

STEEL FRAMING SUPPORT IN FEILD

CL

CL

CL

CL

CLCL

CL

2"

4"

INSTALL FENCING WITH TAMPER-PROOF

NUTS AND BOLTS

G.C. TO INSTALL LIGHTNING CONDUCTOR

CONNECTED TO DOWNCONDUCTOR AND

EARTHING SYSTEM

G.C. TO INSTALL LIGHTNING CONDUCTOR

CONNECTED TO DOWNCONDUCTOR AND

EARTHING SYSTEM

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

TL.LVL3-A003

CLC RAILING MODIFICATIONS - DETAILS

FEMI FEMI10/19/17

O6629-18-104SLVHCS MEDICAL CENTER

NEW ORLEANS, LOUISIANA

Department of Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

1 1/2" = 1'-0"1

LEVEL 3 PATIENT TERRACE

MODIFICATIONS - SECTION 2

Sheets
TL.LVL3-A003 - CLC RAILING MODIFICATIONS - DETAILS

File details come from the government source that posted it.