36C25618R0574-013.pdf

PDF 117 KB Posted

Attached to
CLC MODIFICATIONS
Solicitation number
36C25618R0574
Issued by

About this file

36C25618R0574 DRAWING TL LVL 3 - A002 - RAILINGS MODIFICATION - EXISTING CONDITIONS.pdf

View the file

Other files

File Type Posted
36C25618R0574-0004000.docx DOCX document
36C25618R0574-0004001.pdf PDF
36C25618R0574-0003000.docx DOCX document
36C25618R0574-0002000.docx DOCX document
36C25618R0574-0001000.docx DOCX document
36C25618R0574-0001001.pdf PDF
36C25618R0574-003.pdf PDF
36C25618R0574-011.pdf PDF
36C25618R0574-014.pdf PDF
36C25618R0574-008.docx DOCX document
36C25618R0574-015.pdf PDF
36C25618R0574-010.pdf PDF
36C25618R0574-007.docx DOCX document
36C25618R0574-002.pdf PDF
36C25618R0574-005.docx DOCX document
36C25618R0574-016.pdf PDF
36C25618R0574-006.docx DOCX document
36C25618R0574-004.xlsx XLSX spreadsheet
36C25618R0574-012.pdf PDF
36C25618R0574-009.pdf PDF
36C25618R0574-001.docx DOCX document
36C25618R0574-000.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CABLE RAIL SYSTEM

TRELLIS

2" X 4" X 3/16" PAINTED STEEL

TOP BEAM WITH END CAPS

WT 2 X 6.5 WELDED TO

STEEL POST

PLANTER

E

XI

ST

IN

G

VE

R

IF

Y

IN

F

IE

LD

3'

1/

2"

E

XI

ST

IN

G T

R

EL

LI

S

H

EI

G H

T

- V

ER

IF

Y

IN

F

IE

LD

6'

0"

4" X 4" X 3/16" STEEL POST

WELDED AT BASE PLATE

CONNECTION BELOW

PRECAST UNIT PAVERS WITH

WIND UPLIFT ANCHOR

MANUFACTURED METAL

FLASHING WITH FLANGE

VA

R

IE

S

PLANTER

INSIDE FENCING OUTSIDE FENCING

G.C. TO CAREFULLY

REMOVE FOR RE-USE

@ LEVEL 3 INTERIOR

PATIENT TERRACE

MAX. POST SPACING

4' - 0"

CL CL

CABLE RAIL SYSTEM

TRELLIS

2" X 4" X 3/16" PAINTED STEEL

TOP BEAM WITH END CAPS

WT 2 X 6.5 WELDED TO

STEEL POST

PLANTER

4" X 4" X 3/16" STEEL POST

WELDED AT BASE PLATE

CONNECTION BELOW

PRECAST UNIT PAVERS WITH

WIND UPLIFT ANCHOR

G.C. TO CAREFULLY

REMOVE FOR RE-USE

@ LEVEL 3 INTERIOR

PATIENT TERRACE

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

TL.LVL3-A002

CLC RAILING MODIFICATIONS - EXISTING

CONDITIONS

FEMI FEMI10/19/17

06629-18-104SLVHCS MEDICAL CENTER

NEW ORLEANS, LOUISIANA

Department of Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

1 1/2" = 1'-0"1

LEVEL 3 PATIENT TERRACE

MODIFICATIONS - EXISTING

CONDITIONS

1 1/2" = 1'-0"2

LEVEL 3 PATIENT TERRACE

MODIFICATIONS - EXISTING FENCE

ELEVATION

Sheets
TL.LVL3-A002 - CLC RAILING MODIFICATIONS - EXISTING CONDITIONS

File details come from the government source that posted it.